{"canonical":"https://sealedbidder.com/opportunities/f3n0425314a001","key":"F3N0425314A001","url":"https://sealedbidder.com/opportunities/f3n0425314a001","title":"435 CTS HVAC","solicitation_number":"F3N0425314A001","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-27T14:30:00Z","first_posted":"2026-03-30","last_posted":"2026-03-30","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA5613 700 CONS PK","naics":"423730","psc":"4120","set_aside":null,"place_state":null,"place_scope":"overseas","site":null,"place_state_source":null,"place_evidence":"GERMANY","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"4fb2e1bf5dc849d88d6c222f1b8034ab","title":"HVAC","solicitation_number":"F3N0425314A001","notice_type":"p","base_type":"p","posted":"2026-03-30","posted_at":"2026-03-30T13:17:14.058Z","due_at":"2026-03-27T14:30:00Z","due_date":"2026-03-27","cancelled":false,"archived":true,"archive_date":"2026-04-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4fb2e1bf5dc849d88d6c222f1b8034ab/view","enriched":true,"history":[{"index":3,"title":"HVAC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T13:17:14.058Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4fb2e1bf5dc849d88d6c222f1b8034ab","solicitation_number":"F3N0425314A001","parent_opportunity_id":"c5e08c42b84a419c97554ebf68ab783a"},{"index":1,"title":"435 CTS HVAC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T07:32:17.619Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c5e08c42b84a419c97554ebf68ab783a","solicitation_number":"F3N0425314A001"}]},{"notice_id":"c5e08c42b84a419c97554ebf68ab783a","title":"435 CTS HVAC","solicitation_number":"F3N0425314A001","notice_type":"p","base_type":"p","posted":"2026-03-30","posted_at":"2026-03-30T07:32:17.619Z","due_at":"2026-03-27T14:30:00Z","due_date":"2026-03-27","cancelled":false,"archived":true,"archive_date":"2026-04-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c5e08c42b84a419c97554ebf68ab783a/view","enriched":true,"history":[{"index":3,"title":"HVAC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T13:17:14.058Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4fb2e1bf5dc849d88d6c222f1b8034ab","solicitation_number":"F3N0425314A001","parent_opportunity_id":"c5e08c42b84a419c97554ebf68ab783a"},{"index":1,"title":"435 CTS HVAC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T07:32:17.619Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c5e08c42b84a419c97554ebf68ab783a","solicitation_number":"F3N0425314A001"}]}],"latest_notice_id":"c5e08c42b84a419c97554ebf68ab783a","first_type":"p","notices":[{"dates":{"posted":"2026-03-30","posted_at":"2026-03-30T13:17:14.058Z","created_at":"2026-03-30T12:56:05.545Z","modified_at":"2026-04-11T04:04:28.436Z","response_deadline":{"raw":"2026-03-27T15:30:00+01:00","utc":"2026-03-27T14:30:00Z","date":"2026-03-27","time":"15:30:00","timezone":"Europe/Berlin","utc_offset_seconds":3600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4fb2e1bf5dc849d88d6c222f1b8034ab/view"},"naics":{"codes":["423730"],"primary":"423730"},"title":"HVAC","agency":{"office":{"code":"FA5613","name":"FA5613 700 CONS PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"09021-3076","city":"APO","state":"AE","country":"USA"},"organization_id":"500034511","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-11","archive_type":"auto15"},"history":[{"index":3,"title":"HVAC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T13:17:14.058Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4fb2e1bf5dc849d88d6c222f1b8034ab","solicitation_number":"F3N0425314A001","parent_opportunity_id":"c5e08c42b84a419c97554ebf68ab783a"},{"index":1,"title":"435 CTS HVAC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T07:32:17.619Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c5e08c42b84a419c97554ebf68ab783a","solicitation_number":"F3N0425314A001"}],"contacts":[{"name":"Damien Orozco","role":"primary","email":"damien.orozco.2@us.af.mil","phone":"3144895869"},{"name":"Autry Fontenot","role":"secondary","email":"autry.fontenot.2@us.af.mil","phone":"3144896787"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"4fb2e1bf5dc849d88d6c222f1b8034ab","lineage_id":"c5e08c42b84a419c97554ebf68ab783a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-09T01:45:27.173818017Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"8d69fe5d1257c6cd3b7c66200de466614b63a019eaa22f2b8a0306eb9e5d4235","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-09T01:45:27.173818017Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>Manufacturing, delivery and assembly of entire air conditioning system, consisting of:<br />\n1. Job Site Mobilization<br />\n- Construction site setup<br />\n- Work platform, scaffolding, and/or ladders. Installation height: max. 3.50 m above floor.</p>\n\n<p>2. Air conditioning system, consisting of:<br />\nDescription: REMKO MVV 2003 DC<br />\nQuantity: 1 each<br />\nManufacturer: Remko</p>\n\n<p>Model: MVV 2003 DC<br />\nItem number: 1623680</p>\n\n<p>Description: Floor console BK-1000 Plus S<br />\nQuantity: 1 each<br />\nManufacturer: Remko<br />\nModel: BK-1000 Plus S<br />\nItem number: 1613273</p>\n\n<p>Description: Condensate collection tray incl. oil separator MVV 2000/Duo<br />\nQuantity: 1 each<br />\nManufacturer: Remko<br />\nModel: MVV 2000/Duo<br />\nItem number: 260128</p>\n\n<p>Description: REMKO MVW 222<br />\nQuantity: 9 each<br />\nManufacturer: Remko<br />\nModel: MVW 222<br />\nItem number: 1623504</p>\n\n<p>Description: KFB-4 wired remote control<br />\nQuantity: 9 each<br />\nManufacturer: Remko<br />\nModel: MVD 222-1002/MVW 222-562<br />\nItem number: 1613269<br />\n- Fixed price for the refrigeration connection of indoor air conditioning units in connection with<br />\nthe technical handover of equipment by REMKO (also for A2L refrigerants in accordance with<br />\nDIN EN 60335-2).<br />\n- The contractor must announce all necessary power requirements for CTS pre-installation.</p>\n\n<p>3. Pipe network:<br />\nRefrigerant pipes made of seamless drawn copper from Cu-DHP, strength R220 soft according to<br />\nEN 12735-1, cleaned inside, pipe ends sealed, with factory-fitted thermal insulation made of<br />\nmodified polyethylene according to DIN EN 14313 with structured white protective film. Building<br />\nmaterial class flame retardant CL s1 d0 according to DIN EN 13501-1, does not drip when burning,<br />\nminimal smoke development. Permissible operating pressure 169 bar with 3-fold safety up to 100 &deg;C<br />\naccording to EN 14276.<br />\nInstallation of pipes in accordance with DIN EN 378-2 and DKI i.164, copper pipes in refrigeration<br />\nand air conditioning technology. Brazing using silver or phosphorus solders in a protective gas<br />\natmosphere. Pressing with special press fittings for refrigerant-carrying pipes in accordance with<br />\nDIN EN ISO 14903.<br />\n<br />\nBrazing is carried out using brazing alloys in accordance with DIN EN ISO 17672, recommended<br />\nbrazing alloys CuP 179 or CuP 279, if necessary, fluxes in accordance with DIN EN 1045 type<br />\nFH10 must be used. For solders AG 134, AG 145, and AG 244, use flux in accordance with DIN<br />\nEN 1045. Type: FH 10. Brazed joints may only be made by qualified personnel. Before and during<br />\nthe joining process by brazing or welding, the pipes must be flushed with dry protective gases, e.g.,<br />\ninert gases (noble gases, nitrogen, and mixtures thereof) or forming gases (e.g., nitrogen-hydrogen,<br />\nnitrogen-argon, etc., max. hydrogen content 4 vol.%). When using capillary solder and press fittings,<br />\nconsult the respective fitting manufacturer regarding the possible areas of application, particularly<br />\nthe maximum permissible operating pressures.<br />\nPipe network consisting of following components:</p>\n\n<p>Description: Refrigeration pipe, insulated, installed according to design.<br />\nQuantity: according to design<br />\nManufacturer: Remko<br />\nModel: 3/8&rdquo;, 3/4&rdquo;, 1/4&rdquo;, 1/2&rdquo;,<br />\nItem number: 260128</p>\n\n<p>Description: Y-distributor set for MVV AT/IT fluid and suction line<br />\nQuantity: 2 sets<br />\nManufacturer: Remko<br />\nItem number: 1611095</p>\n\n<p>Description: 4-way distributor set for liquid gas and suction line<br />\nQuantity: 2 sets<br />\nManufacturer: Remko<br />\nItem number: 1611096</p>\n\n<p>Description: Condensation hose 16/18 mm diameter, per meter<br />\nQuantity: 1 each per wall unit<br />\nManufacturer: Remko<br />\nItem number: 1613053</p>\n\n<p>Description: Condensation pump KP-6<br />\nQuantity: 1 each per wall unit<br />\nManufacturer: Remko<br />\nItem number: 1613251</p>\n\n<p>The installation of the distribution sets involves connecting and soldering the refrigerant lines<br />\nalready connected by the installer to the distributors. Since absolute cleanliness must be ensured<br />\nin this complex pipe system, soldering is carried out under dry nitrogen.<br />\n<br />\n4. Miscellaneous / Additional services, special services:<br />\n- The pipe dimensions must be checked by the contractor and adjusted if necessary.<br />\n- The contractor must adjust the system components so that the planned functions and<br />\nperformance are achieved and the legal requirements are met. The air volume flows must be<br />\nadjusted in accordance with the calculated settings. Measured values must be documented.<br />\n- The contractor shall provide one-time training for the operating and maintenance personnel for<br />\nthe system. Leading time for coordination: 2 weeks.<br />\n- If necessary, the delivery and installation of special fastening structures, e.g., brackets and<br />\nsupport frames is also part of this contract.<br />\n- Delivery of the operating materials and media required for commissioning and trial operation,<br />\nparticularly the required refrigerant R 410A.</p>\n\n<p>5. As-built documentation<br />\nAs-built documentation, digital revision documents in German and English language including:<br />\n- System diagrams.<br />\n- General electrical diagrams and connection diagrams in accordance with DIN EN 61082-1</p>\n\n<p>&ldquo;Electrotechnical documentation &rdquo;<br />\n- Compilation of the key technical data.<br />\n- Copies of the required test and manufacturer certificates.<br />\n- All operating and maintenance documents, required for safe and economical operation.<br />\n- Protocol on the training of maintenance and operating personnel.</p>\n\n<p>FAR 52.225-5, Trade Agreements&ldquo;One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements.</p>","text":"Manufacturing, delivery and assembly of entire air conditioning system, consisting of:\n\n1. Job Site Mobilization\n\n- Construction site setup\n\n- Work platform, scaffolding, and/or ladders. Installation height: max. 3.50 m above floor.\n\n2. Air conditioning system, consisting of:\n\nDescription: REMKO MVV 2003 DC\n\nQuantity: 1 each\n\nManufacturer: Remko\n\nModel: MVV 2003 DC\n\nItem number: 1623680\n\nDescription: Floor console BK-1000 Plus S\n\nQuantity: 1 each\n\nManufacturer: Remko\n\nModel: BK-1000 Plus S\n\nItem number: 1613273\n\nDescription: Condensate collection tray incl. oil separator MVV 2000/Duo\n\nQuantity: 1 each\n\nManufacturer: Remko\n\nModel: MVV 2000/Duo\n\nItem number: 260128\n\nDescription: REMKO MVW 222\n\nQuantity: 9 each\n\nManufacturer: Remko\n\nModel: MVW 222\n\nItem number: 1623504\n\nDescription: KFB-4 wired remote control\n\nQuantity: 9 each\n\nManufacturer: Remko\n\nModel: MVD 222-1002/MVW 222-562\n\nItem number: 1613269\n\n- Fixed price for the refrigeration connection of indoor air conditioning units in connection with\n\nthe technical handover of equipment by REMKO (also for A2L refrigerants in accordance with\n\nDIN EN 60335-2).\n\n- The contractor must announce all necessary power requirements for CTS pre-installation.\n\n3. Pipe network:\n\nRefrigerant pipes made of seamless drawn copper from Cu-DHP, strength R220 soft according to\n\nEN 12735-1, cleaned inside, pipe ends sealed, with factory-fitted thermal insulation made of\n\nmodified polyethylene according to DIN EN 14313 with structured white protective film. Building\n\nmaterial class flame retardant CL s1 d0 according to DIN EN 13501-1, does not drip when burning,\n\nminimal smoke development. Permissible operating pressure 169 bar with 3-fold safety up to 100 °C\n\naccording to EN 14276.\n\nInstallation of pipes in accordance with DIN EN 378-2 and DKI i.164, copper pipes in refrigeration\n\nand air conditioning technology. Brazing using silver or phosphorus solders in a protective gas\n\natmosphere. Pressing with special press fittings for refrigerant-carrying pipes in accordance with\n\nDIN EN ISO 14903.\n\nBrazing is carried out using brazing alloys in accordance with DIN EN ISO 17672, recommended\n\nbrazing alloys CuP 179 or CuP 279, if necessary, fluxes in accordance with DIN EN 1045 type\n\nFH10 must be used. For solders AG 134, AG 145, and AG 244, use flux in accordance with DIN\n\nEN 1045. Type: FH 10. Brazed joints may only be made by qualified personnel. Before and during\n\nthe joining process by brazing or welding, the pipes must be flushed with dry protective gases, e.g.,\n\ninert gases (noble gases, nitrogen, and mixtures thereof) or forming gases (e.g., nitrogen-hydrogen,\n\nnitrogen-argon, etc., max. hydrogen content 4 vol.%). When using capillary solder and press fittings,\n\nconsult the respective fitting manufacturer regarding the possible areas of application, particularly\n\nthe maximum permissible operating pressures.\n\nPipe network consisting of following components:\n\nDescription: Refrigeration pipe, insulated, installed according to design.\n\nQuantity: according to design\n\nManufacturer: Remko\n\nModel: 3/8”, 3/4”, 1/4”, 1/2”,\n\nItem number: 260128\n\nDescription: Y-distributor set for MVV AT/IT fluid and suction line\n\nQuantity: 2 sets\n\nManufacturer: Remko\n\nItem number: 1611095\n\nDescription: 4-way distributor set for liquid gas and suction line\n\nQuantity: 2 sets\n\nManufacturer: Remko\n\nItem number: 1611096\n\nDescription: Condensation hose 16/18 mm diameter, per meter\n\nQuantity: 1 each per wall unit\n\nManufacturer: Remko\n\nItem number: 1613053\n\nDescription: Condensation pump KP-6\n\nQuantity: 1 each per wall unit\n\nManufacturer: Remko\n\nItem number: 1613251\n\nThe installation of the distribution sets involves connecting and soldering the refrigerant lines\n\nalready connected by the installer to the distributors. Since absolute cleanliness must be ensured\n\nin this complex pipe system, soldering is carried out under dry nitrogen.\n\n4. Miscellaneous / Additional services, special services:\n\n- The pipe dimensions must be checked by the contractor and adjusted if necessary.\n\n- The contractor must adjust the system components so that the planned functions and\n\nperformance are achieved and the legal requirements are met. The air volume flows must be\n\nadjusted in accordance with the calculated settings. Measured values must be documented.\n\n- The contractor shall provide one-time training for the operating and maintenance personnel for\n\nthe system. Leading time for coordination: 2 weeks.\n\n- If necessary, the delivery and installation of special fastening structures, e.g., brackets and\n\nsupport frames is also part of this contract.\n\n- Delivery of the operating materials and media required for commissioning and trial operation,\n\nparticularly the required refrigerant R 410A.\n\n5. As-built documentation\n\nAs-built documentation, digital revision documents in German and English language including:\n\n- System diagrams.\n\n- General electrical diagrams and connection diagrams in accordance with DIN EN 61082-1\n\n“Electrotechnical documentation ”\n\n- Compilation of the key technical data.\n\n- Copies of the required test and manufacturer certificates.\n\n- All operating and maintenance documents, required for safe and economical operation.\n\n- Protocol on the training of maintenance and operating personnel.\n\nFAR 52.225-5, Trade Agreements“One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"F3N0425314A001","place_of_performance":{"city":{"code":"Kaiserslautern","name":"Kaiserslautern"},"state":{"code":"DE-RP","name":"Rhineland-Palatinate"},"country":{"code":"DEU","name":"GERMANY"}},"product_service_code":"4120"},{"dates":{"posted":"2026-03-30","posted_at":"2026-03-30T07:32:17.619Z","created_at":"2026-03-27T14:06:32.600Z","modified_at":"2026-04-11T04:04:28.436Z","response_deadline":{"raw":"2026-03-27T15:30:00+01:00","utc":"2026-03-27T14:30:00Z","date":"2026-03-27","time":"15:30:00","timezone":"Europe/Berlin","utc_offset_seconds":3600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c5e08c42b84a419c97554ebf68ab783a/view"},"naics":{"codes":["423730"],"primary":"423730"},"title":"435 CTS HVAC","agency":{"office":{"code":"FA5613","name":"FA5613 700 CONS PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"09021-3076","city":"APO","state":"AE","country":"USA"},"organization_id":"500034511","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-11","archive_type":"auto15"},"history":[{"index":3,"title":"HVAC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T13:17:14.058Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4fb2e1bf5dc849d88d6c222f1b8034ab","solicitation_number":"F3N0425314A001","parent_opportunity_id":"c5e08c42b84a419c97554ebf68ab783a"},{"index":1,"title":"435 CTS HVAC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-30T07:32:17.619Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c5e08c42b84a419c97554ebf68ab783a","solicitation_number":"F3N0425314A001"}],"contacts":[{"name":"Damien Orozco","role":"primary","email":"damien.orozco.2@us.af.mil","phone":"3144895869"},{"name":"Autry Fontenot","role":"secondary","email":"autry.fontenot.2@us.af.mil","phone":"3144896787"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"c5e08c42b84a419c97554ebf68ab783a","lineage_id":"c5e08c42b84a419c97554ebf68ab783a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-09T02:05:39.204700836Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"c8d4190db9d069c635f9311519ee0e95ebc113c522094b97d1f8ace54c8d8958","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-09T02:05:39.204700836Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>Please see attached documents:&nbsp;<br />\n1. SOW AC 20250930</p>","text":"Please see attached documents:\n\n1. SOW AC 20250930","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"F3N0425314A001","place_of_performance":{"city":{"code":"Kaiserslautern","name":"Kaiserslautern"},"state":{"code":"DE-RP","name":"Rhineland-Palatinate"},"country":{"code":"DEU","name":"GERMANY"}},"product_service_code":"4120"}],"due_at":"2026-03-27T14:30:00Z","due_date":"2026-03-27","closes_at":"2026-03-27T14:30:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA5613","office_name":"FA5613 700 CONS PK","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"DEU","state_source":null,"state_evidence":"GERMANY","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-09T02:59:55.241942Z","principal_notice_id":"c5e08c42b84a419c97554ebf68ab783a","description":{"text":"Please see attached documents:\n\n1. SOW AC 20250930","html":"<p>Please see attached documents:&nbsp;<br />\n1. SOW AC 20250930</p>","origin":"detail"},"contacts":[{"name":"Damien Orozco","role":"primary","email":"damien.orozco.2@us.af.mil","phone":"3144895869"},{"name":"Autry Fontenot","role":"secondary","email":"autry.fontenot.2@us.af.mil","phone":"3144896787"}],"place_of_performance":{"city":{"code":"Kaiserslautern","name":"Kaiserslautern"},"state":{"code":"DE-RP","name":"Rhineland-Palatinate"},"country":{"code":"DEU","name":"GERMANY"}},"office_address":{"zip":"09021-3076","city":"APO","state":"AE","country":"USA"},"naics_codes":["423730"],"award":null,"attachments":[],"awards":[],"related":[{"key":"FA561325Q0028","latest_notice_id":"29907243eb4e4fad815c40392ee0c90f","title":"Maintenance, Repair, and Inspection of Hoists in the Kaiserslautern Military Community (KMC)","solicitation_number":"FA5613-25-Q-0028","notice_type":"k","first_type":"k","first_posted":"2025-07-18","last_posted":"2025-08-14","notices":2,"due_at":"2028-08-22T12:00:00Z","due_date":"2028-08-22","closes_at":"2028-08-22T12:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA5613","office_name":"FA5613 700 CONS PK","naics":"811310","psc":"J036","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"DEU","place_scope":"overseas","state_source":null,"state_evidence":"GERMANY","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open":[],"similar_open_total":0,"indexable":false}