Combined synopsis and solicitation
Substation Maintenance
F2B3AQ4079AW09
Department of the Air Force, FA2835 AFLCMC Hanscom Pzi. Power and Communication Line and Related Structures Construction.
Response deadline
August 30, 2024 at 12:00 PM EDT
Closed 817 days ago. Posted August 19, 2024, first published August 19, 2024. Scheduled to archive September 14, 2024.
Get the next one like this from Department of the Air Force by email, the day it is posted.Find my opportunities
This one closed in 2024
7 like it are open now in power and communication line and related structures construction
- FCI Marion - Emergency Repair Tornado Damage
Federal Prison System / Bureau of Prisons, Fao
Combined synopsis and solicitationSmall businessNAICS 237130Marion, IL15BBNF26Q40900001Closes in 8 daysDec 3 - N6247327R0006 Project Labor Agreement Request for Information
Department of the Navy, Navfacsyscom Southwest
PresolicitationNAICS 237130San Diego, CAN6247327R0006Closes in 8 daysDec 3 - DLA DWCF B1907 Backup Power Generator, Yokosuka, Japan
Department of the Army, W2SN Endist Japan
Sources soughtNAICS 237130Outside the USW912HV27Z0002Closes in 16 daysDec 11
All 7 open in power and communication line and related structures construction
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 237130 (power and communication line and related structures construction), means no more than $45 million in average annual receipts, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 11 days from the day the solicitation was posted, August 19, 2024, to the deadline.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The substations at Hanscom AFB need to be serviced and maintained at the required intervals. The substations must be serviced and maintained to ensure the unrestricted flow of electricity to the base.
The contractor shall provide all labor, tools, equipment, materials, supplies and parts, transportation and other incidentals necessary to travel to Hanscom AFB, MA, to to inspect, test, and perform preventive and predictive diagnosis maintenance to substations in accordance with all applicable State, Federal and Local codes and regulations. Specific standards are AFH 32-1282, AFI 32-1065, NFPA 70B and OSHA. The goal is to ensure high confidence levels in electrical service required for the entire installation.
The contractor is primarily to perform routine maintenance and associated repairs. The contractor shall be responsible for ensuring all services and parts provided under this contract are in accordance with the terms and conditions outlined herein and conform to the manufacturer’s equipment specifications and this Performance Work Statement (PWS).