{"canonical":"https://sealedbidder.com/opportunities/dlaaberdeen25035","key":"DLAABERDEEN25035","url":"https://sealedbidder.com/opportunities/dlaaberdeen25035","title":"Market Survey for Procurement of NSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL, and 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL","solicitation_number":"DLA-Aberdeen-25-035","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-01T20:30:00Z","first_posted":"2025-03-14","last_posted":"2025-03-14","department":"DEPT OF DEFENSE","subagency":"DEFENSE LOGISTICS AGENCY","office":"DLA LAND AT ABERDEEN","naics":"334111","psc":"6150","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6150)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"c6ee338bdf8b4d8fa10d9fbc393f281d","title":"Market Survey for Procurement of NSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL, and 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL","solicitation_number":"DLA-Aberdeen-25-035","notice_type":"r","base_type":"r","posted":"2025-03-14","posted_at":"2025-03-14T17:05:07.856Z","due_at":"2025-04-01T20:30:00Z","due_date":"2025-04-01","cancelled":false,"archived":true,"archive_date":"2025-04-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c6ee338bdf8b4d8fa10d9fbc393f281d/view","enriched":true,"history":[{"index":3,"title":"Market Survey for Procurement of NSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL, and 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T17:05:07.856Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c6ee338bdf8b4d8fa10d9fbc393f281d","solicitation_number":"DLA-Aberdeen-25-035"}]}],"latest_notice_id":"c6ee338bdf8b4d8fa10d9fbc393f281d","first_type":"r","notices":[{"dates":{"posted":"2025-03-14","posted_at":"2025-03-14T17:05:07.856Z","created_at":"2025-03-14T16:58:00.522Z","modified_at":"2025-04-17T03:55:48.918Z","response_deadline":{"raw":"2025-04-01T16:30:00-04:00","utc":"2025-04-01T20:30:00Z","date":"2025-04-01","time":"16:30:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c6ee338bdf8b4d8fa10d9fbc393f281d/view"},"naics":{"codes":["334111"],"primary":"334111"},"title":"Market Survey for Procurement of NSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL, and 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL","agency":{"office":{"code":"SPRBL1","name":"DLA LAND AT ABERDEEN"},"subtier":{"code":"97AS","name":"DEFENSE LOGISTICS AGENCY"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"21005","city":"ABER PROV GRD","state":"MD","country":"USA"},"organization_id":"500017761","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-16","archive_type":"auto15"},"history":[{"index":3,"title":"Market Survey for Procurement of NSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL, and 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T17:05:07.856Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c6ee338bdf8b4d8fa10d9fbc393f281d","solicitation_number":"DLA-Aberdeen-25-035"}],"contacts":[{"name":"Kenneth Vereb","role":"primary","email":"kenneth.m.vereb2.civ@army.mil"},{"name":"DLA Land and Maritime SBO","role":"secondary","email":"smbizlandcols@dla.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"c6ee338bdf8b4d8fa10d9fbc393f281d","lineage_id":"c6ee338bdf8b4d8fa10d9fbc393f281d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T09:52:44.233058601Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"d66a699dee265e9df3618e1fac4e2673301793504bab05b2211cc352ead3ab1f","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-20T09:52:44.233058601Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong><u>DESCRIPTION: &nbsp;&nbsp;Common</u></strong></p>\n\n<p></p>\n\n<p><strong><u>Cable Illustration:</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Wall Outlet End</strong></p>\n\n<p>Wire&nbsp; Length: 12.5 Ft</p>\n\n<p>Plug: NEMA 5-15 Plug</p>\n\n<p>Current Wire:</p>\n\n<p>Wire Type: As Marked E94325-A1 90o C SJ 3X1.31mm2 (16 AWG)&nbsp; 300V&nbsp; CSA 60o&nbsp; C LL60382 FT2 TA TUN</p>\n\n<p>Cable is for reference only Contractor may choose appropriate alternate.</p>\n\n<p></p>\n\n<p><strong>Equipment End</strong></p>\n\n<p>Wire Length: 2 Ft</p>\n\n<p>Plug: As marked Amphenol&nbsp; 0935 PT06E-12-3S (SR) 168815001</p>\n\n<p>Cap:&nbsp; As Marked GLENAIR JAN MS3180-12CA 0924</p>\n\n<p>Wire Type: same as Wall Outlet End</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>GFCI Specifications</strong></p>\n\n<p><strong>Common</strong></p>\n\n<p>GROUNDED NEUTRAL: 4 Ohms Typical</p>\n\n<p>VOLTAGE SURGE WITHSTAND: 3 Kv Ringwave Test and 4Kv/2Ka Surge Immunity Test</p>\n\n<p>RADIO FREQUENECY NOISE SUSCEPTABILITY: Operates Within Normal Limits With 0.5 Volts Injected On Power Line 150Khz-230Mhz</p>\n\n<p>ENDURANCE: 3,000 Operations Minimum</p>\n\n<p>OVERLOAD CURRENT: Six Times Rated Current</p>\n\n<p>OPERATING TEMPERATURE RANGE: -35&deg;C to 66&deg;C</p>\n\n<p>EFFECT OF 10 AMP TURN DC SOCK FAULT TRIP: 5% Maximum Trip Level Variation on Ground</p>\n\n<p>INSULATION VOLTAGE: 1500 Vrms - 1 Min.</p>\n\n<p>POWER INDICTATION: Lighted Indicator</p>\n\n<p>Trip Point: Up to 30MA</p>\n\n<p>Trip Response Time: less than 25 MS</p>\n\n<p>Manual Reset</p>\n\n<p></p>\n\n<p>&nbsp;&nbsp;<strong>SPECIFIC To NSN</strong></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9145, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL 120Volt CAGE 1UB81 P/N 0056-1010-01</u></strong></p>\n\n<p><strong><u>For 120 Volt </u></strong></p>\n\n<p>Southwire Model Number 25230001-6 Or equivalent</p>\n\n<p>120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA</p>\n\n<p>See Attachment</p>\n\n<p></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9148, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL&nbsp; 240Volt CAGE 1UB81 P/N 0056-1010-02</u></strong></p>\n\n<p><strong><u>For 240 Volt</u></strong></p>\n\n<p></p>\n\n<p>Southwire Model Number 26000200-6 or equivalent</p>\n\n<p>240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA</p>\n\n<p>See attachment</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Reference Photographs:</strong></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <u>REFERENCE Drawing</u></strong></p>\n\n<p></p>\n\n<p><strong>NSN Specific Data</strong></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9145, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL CAGE 1UB81 P/N 0056-1010-01</u></strong></p>\n\n<p></p>\n\n<p>Must meet the following &nbsp;or equivalent</p>\n\n<p>For 120 Volt</p>\n\n<p>Southwire Model Number 25230001-6 Or equivalent</p>\n\n<p>120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA</p>\n\n<p>See Attachment</p>\n\n<p></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9148, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL CAGE 1UB81 P/N 0056-1010-02</u></strong></p>\n\n<p></p>\n\n<p>Must meet the following&nbsp; or equivalent</p>\n\n<p>For 240Volt</p>\n\n<p>Southwire Model Number 26000200-6 or equivalent</p>\n\n<p>240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><u>ATTACHMENTS:</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><u>ALTERNATE Southwire Cut Sheet SW-1003814_DL.pdf</u></strong></p>\n\n<p><strong><u>ALTERNATE Southwire Catalog Pages.pdf</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><u>SYSTEM SUPPORTED</u></strong></p>\n\n<p></p>\n\n<p><strong><u>CSS-VSAT AN/TSC-183A</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><u>WEAPON SYSTEM DIRECTORATE</u></strong></p>\n\n<p></p>\n\n<p><strong><u>&nbsp;&nbsp; C3T&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </u></strong></p>\n\n<p></p>\n\n<p>.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>***************************************************************************************</strong></p>\n\n<p></p>\n\n<p>The Defense Logistics Agency-Aberdeen, on behalf of the Army Integrated Logistics Supply Center (ILSC), intends to acquire 500 each <strong><u>NSN&rsquo;s 6150-01-700-9145 and 6150-01-700-9148 </u></strong>to support the Combat Service Support Very Small Apeture Terminal (CSS-VSAT) AN/TSC-183A</p>\n\n<p></p>\n\n<p><u>Items and/or Services to Be Procured:</u></p>\n\n<p></p>\n\n<p><u>Requirements Description:</u></p>\n\n<p></p>\n\n<p>GFCI Cables:</p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9145, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL 120Volt CAGE 1UB81 P/N 0056-1010-01</u></strong></p>\n\n<p></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9148, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL&nbsp; 240Volt CAGE 1UB81 P/N 0056-1010-02</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p>The Government does not &nbsp;possess the technical data package (TDP) for the parts.</p>\n\n<p></p>\n\n<p>The following additional NAICS apply:<br />\n334220</p>\n\n<p></p>\n\n<p></p>\n\n<p><u>Requested Response Information:</u></p>\n\n<p></p>\n\n<p>We request that sources who can Manufacturing a or supply the listed parts.&nbsp; At a minimum the support information you submit should include, but is not limited to, the following types of documentation: Questionnaire, purchase orders showing your ability to supply either or both of&nbsp; the items listed. Note: TDP is not available.</p>\n\n<p></p>\n\n<p>In your response, please include your company name, CAGE code, and a technical point of contract with email address and telephone number.</p>\n\n<p></p>\n\n<p></p>\n\n<p><u>Notice, Response Due Date, and Points of Contact:</u></p>\n\n<p></p>\n\n<p>This is NOT a Request for Quote or Proposal. The Government does not intend to award a contract on the basis of this SSA or reimburse any costs associated with the preparation of responses to this SSA. This Sources sought announcement (SSA) is for planning and market research purposes only, and shall not be construed as a commitment by the Government. The information gathered from this announcement will be used to determine if responsible sources exist, and to assist in determining if this effort can be competitive and/or set aside for Small Business.&nbsp; Furthermore, the Government will use the information, in part, to determine the best acquisition strategy for a potential procurement action and/or to assist in making acquisition strategy decisions in the future.</p>\n\n<p></p>\n\n<p>All SSA responses should be emailed to the Technical and Competition Advocate Points of Contact at the email addresses listed below. No phone inquiries will be accepted, either as a response to this action or for information requests.&nbsp; All requests for information must be submitted via email to the Technical Point of Contact and the Competition Advocate.</p>\n\n<p></p>\n\n<p>Please submit responses by 01 April 2025</p>\n\n<p></p>\n\n<p>Technical Point of Contact: <strong><u>Kenneth M. Vereb Email: </u></strong><strong>Kenneth.m.vereb2.civ@army.mil</strong><strong><u> Phone 520-674-6033</u></strong></p>\n\n<p></p>\n\n<p><strong>DLA Aberdeen Small Business:</strong> smbizlandcols@dla.mil</p>\n\n<p></p>\n\n<p></p>","text":"DESCRIPTION: Common\n\nCable Illustration:\n\nWall Outlet End\n\nWire Length: 12.5 Ft\n\nPlug: NEMA 5-15 Plug\n\nCurrent Wire:\n\nWire Type: As Marked E94325-A1 90o C SJ 3X1.31mm2 (16 AWG) 300V CSA 60o C LL60382 FT2 TA TUN\n\nCable is for reference only Contractor may choose appropriate alternate.\n\nEquipment End\n\nWire Length: 2 Ft\n\nPlug: As marked Amphenol 0935 PT06E-12-3S (SR) 168815001\n\nCap: As Marked GLENAIR JAN MS3180-12CA 0924\n\nWire Type: same as Wall Outlet End\n\nGFCI Specifications\n\nCommon\n\nGROUNDED NEUTRAL: 4 Ohms Typical\n\nVOLTAGE SURGE WITHSTAND: 3 Kv Ringwave Test and 4Kv/2Ka Surge Immunity Test\n\nRADIO FREQUENECY NOISE SUSCEPTABILITY: Operates Within Normal Limits With 0.5 Volts Injected On Power Line 150Khz-230Mhz\n\nENDURANCE: 3,000 Operations Minimum\n\nOVERLOAD CURRENT: Six Times Rated Current\n\nOPERATING TEMPERATURE RANGE: -35°C to 66°C\n\nEFFECT OF 10 AMP TURN DC SOCK FAULT TRIP: 5% Maximum Trip Level Variation on Ground\n\nINSULATION VOLTAGE: 1500 Vrms - 1 Min.\n\nPOWER INDICTATION: Lighted Indicator\n\nTrip Point: Up to 30MA\n\nTrip Response Time: less than 25 MS\n\nManual Reset\n\nSPECIFIC To NSN\n\nNSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL 120Volt CAGE 1UB81 P/N 0056-1010-01\n\nFor 120 Volt\n\nSouthwire Model Number 25230001-6 Or equivalent\n\n120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA\n\nSee Attachment\n\nNSN’s 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL 240Volt CAGE 1UB81 P/N 0056-1010-02\n\nFor 240 Volt\n\nSouthwire Model Number 26000200-6 or equivalent\n\n240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA\n\nSee attachment\n\nReference Photographs:\n\nREFERENCE Drawing\n\nNSN Specific Data\n\nNSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL CAGE 1UB81 P/N 0056-1010-01\n\nMust meet the following or equivalent\n\nFor 120 Volt\n\nSouthwire Model Number 25230001-6 Or equivalent\n\n120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA\n\nSee Attachment\n\nNSN’s 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL CAGE 1UB81 P/N 0056-1010-02\n\nMust meet the following or equivalent\n\nFor 240Volt\n\nSouthwire Model Number 26000200-6 or equivalent\n\n240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA\n\nATTACHMENTS:\n\nALTERNATE Southwire Cut Sheet SW-1003814_DL.pdf\n\nALTERNATE Southwire Catalog Pages.pdf\n\nSYSTEM SUPPORTED\n\nCSS-VSAT AN/TSC-183A\n\nWEAPON SYSTEM DIRECTORATE\n\nC3T\n\n.\n\n***************************************************************************************\n\nThe Defense Logistics Agency-Aberdeen, on behalf of the Army Integrated Logistics Supply Center (ILSC), intends to acquire 500 each NSN’s 6150-01-700-9145 and 6150-01-700-9148 to support the Combat Service Support Very Small Apeture Terminal (CSS-VSAT) AN/TSC-183A\n\nItems and/or Services to Be Procured:\n\nRequirements Description:\n\nGFCI Cables:\n\nNSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL 120Volt CAGE 1UB81 P/N 0056-1010-01\n\nNSN’s 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL 240Volt CAGE 1UB81 P/N 0056-1010-02\n\nThe Government does not possess the technical data package (TDP) for the parts.\n\nThe following additional NAICS apply:\n\n334220\n\nRequested Response Information:\n\nWe request that sources who can Manufacturing a or supply the listed parts. At a minimum the support information you submit should include, but is not limited to, the following types of documentation: Questionnaire, purchase orders showing your ability to supply either or both of the items listed. Note: TDP is not available.\n\nIn your response, please include your company name, CAGE code, and a technical point of contract with email address and telephone number.\n\nNotice, Response Due Date, and Points of Contact:\n\nThis is NOT a Request for Quote or Proposal. The Government does not intend to award a contract on the basis of this SSA or reimburse any costs associated with the preparation of responses to this SSA. This Sources sought announcement (SSA) is for planning and market research purposes only, and shall not be construed as a commitment by the Government. The information gathered from this announcement will be used to determine if responsible sources exist, and to assist in determining if this effort can be competitive and/or set aside for Small Business. Furthermore, the Government will use the information, in part, to determine the best acquisition strategy for a potential procurement action and/or to assist in making acquisition strategy decisions in the future.\n\nAll SSA responses should be emailed to the Technical and Competition Advocate Points of Contact at the email addresses listed below. No phone inquiries will be accepted, either as a response to this action or for information requests. All requests for information must be submitted via email to the Technical Point of Contact and the Competition Advocate.\n\nPlease submit responses by 01 April 2025\n\nTechnical Point of Contact: Kenneth M. Vereb Email: Kenneth.m.vereb2.civ@army.mil Phone 520-674-6033\n\nDLA Aberdeen Small Business: smbizlandcols@dla.mil","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"DLA-Aberdeen-25-035","product_service_code":"6150"}],"due_at":"2025-04-01T20:30:00Z","due_date":"2025-04-01","closes_at":"2025-04-01T20:30:00Z","awardable":true,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRBL1","office_name":"DLA LAND AT ABERDEEN","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6150)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-20T09:54:53.132167Z","principal_notice_id":"c6ee338bdf8b4d8fa10d9fbc393f281d","description":{"text":"DESCRIPTION: Common\n\nCable Illustration:\n\nWall Outlet End\n\nWire Length: 12.5 Ft\n\nPlug: NEMA 5-15 Plug\n\nCurrent Wire:\n\nWire Type: As Marked E94325-A1 90o C SJ 3X1.31mm2 (16 AWG) 300V CSA 60o C LL60382 FT2 TA TUN\n\nCable is for reference only Contractor may choose appropriate alternate.\n\nEquipment End\n\nWire Length: 2 Ft\n\nPlug: As marked Amphenol 0935 PT06E-12-3S (SR) 168815001\n\nCap: As Marked GLENAIR JAN MS3180-12CA 0924\n\nWire Type: same as Wall Outlet End\n\nGFCI Specifications\n\nCommon\n\nGROUNDED NEUTRAL: 4 Ohms Typical\n\nVOLTAGE SURGE WITHSTAND: 3 Kv Ringwave Test and 4Kv/2Ka Surge Immunity Test\n\nRADIO FREQUENECY NOISE SUSCEPTABILITY: Operates Within Normal Limits With 0.5 Volts Injected On Power Line 150Khz-230Mhz\n\nENDURANCE: 3,000 Operations Minimum\n\nOVERLOAD CURRENT: Six Times Rated Current\n\nOPERATING TEMPERATURE RANGE: -35°C to 66°C\n\nEFFECT OF 10 AMP TURN DC SOCK FAULT TRIP: 5% Maximum Trip Level Variation on Ground\n\nINSULATION VOLTAGE: 1500 Vrms - 1 Min.\n\nPOWER INDICTATION: Lighted Indicator\n\nTrip Point: Up to 30MA\n\nTrip Response Time: less than 25 MS\n\nManual Reset\n\nSPECIFIC To NSN\n\nNSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL 120Volt CAGE 1UB81 P/N 0056-1010-01\n\nFor 120 Volt\n\nSouthwire Model Number 25230001-6 Or equivalent\n\n120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA\n\nSee Attachment\n\nNSN’s 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL 240Volt CAGE 1UB81 P/N 0056-1010-02\n\nFor 240 Volt\n\nSouthwire Model Number 26000200-6 or equivalent\n\n240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA\n\nSee attachment\n\nReference Photographs:\n\nREFERENCE Drawing\n\nNSN Specific Data\n\nNSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL CAGE 1UB81 P/N 0056-1010-01\n\nMust meet the following or equivalent\n\nFor 120 Volt\n\nSouthwire Model Number 25230001-6 Or equivalent\n\n120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA\n\nSee Attachment\n\nNSN’s 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL CAGE 1UB81 P/N 0056-1010-02\n\nMust meet the following or equivalent\n\nFor 240Volt\n\nSouthwire Model Number 26000200-6 or equivalent\n\n240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA\n\nATTACHMENTS:\n\nALTERNATE Southwire Cut Sheet SW-1003814_DL.pdf\n\nALTERNATE Southwire Catalog Pages.pdf\n\nSYSTEM SUPPORTED\n\nCSS-VSAT AN/TSC-183A\n\nWEAPON SYSTEM DIRECTORATE\n\nC3T\n\n.\n\n***************************************************************************************\n\nThe Defense Logistics Agency-Aberdeen, on behalf of the Army Integrated Logistics Supply Center (ILSC), intends to acquire 500 each NSN’s 6150-01-700-9145 and 6150-01-700-9148 to support the Combat Service Support Very Small Apeture Terminal (CSS-VSAT) AN/TSC-183A\n\nItems and/or Services to Be Procured:\n\nRequirements Description:\n\nGFCI Cables:\n\nNSN’s 6150-01-700-9145, CABLE ASSEMBLY,POWER,ELECTRICAL 120Volt CAGE 1UB81 P/N 0056-1010-01\n\nNSN’s 6150-01-700-9148, CABLE ASSEMBLY,POWER,ELECTRICAL 240Volt CAGE 1UB81 P/N 0056-1010-02\n\nThe Government does not possess the technical data package (TDP) for the parts.\n\nThe following additional NAICS apply:\n\n334220\n\nRequested Response Information:\n\nWe request that sources who can Manufacturing a or supply the listed parts. At a minimum the support information you submit should include, but is not limited to, the following types of documentation: Questionnaire, purchase orders showing your ability to supply either or both of the items listed. Note: TDP is not available.\n\nIn your response, please include your company name, CAGE code, and a technical point of contract with email address and telephone number.\n\nNotice, Response Due Date, and Points of Contact:\n\nThis is NOT a Request for Quote or Proposal. The Government does not intend to award a contract on the basis of this SSA or reimburse any costs associated with the preparation of responses to this SSA. This Sources sought announcement (SSA) is for planning and market research purposes only, and shall not be construed as a commitment by the Government. The information gathered from this announcement will be used to determine if responsible sources exist, and to assist in determining if this effort can be competitive and/or set aside for Small Business. Furthermore, the Government will use the information, in part, to determine the best acquisition strategy for a potential procurement action and/or to assist in making acquisition strategy decisions in the future.\n\nAll SSA responses should be emailed to the Technical and Competition Advocate Points of Contact at the email addresses listed below. No phone inquiries will be accepted, either as a response to this action or for information requests. All requests for information must be submitted via email to the Technical Point of Contact and the Competition Advocate.\n\nPlease submit responses by 01 April 2025\n\nTechnical Point of Contact: Kenneth M. Vereb Email: Kenneth.m.vereb2.civ@army.mil Phone 520-674-6033\n\nDLA Aberdeen Small Business: smbizlandcols@dla.mil","html":"<p><strong><u>DESCRIPTION: &nbsp;&nbsp;Common</u></strong></p>\n\n<p></p>\n\n<p><strong><u>Cable Illustration:</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Wall Outlet End</strong></p>\n\n<p>Wire&nbsp; Length: 12.5 Ft</p>\n\n<p>Plug: NEMA 5-15 Plug</p>\n\n<p>Current Wire:</p>\n\n<p>Wire Type: As Marked E94325-A1 90o C SJ 3X1.31mm2 (16 AWG)&nbsp; 300V&nbsp; CSA 60o&nbsp; C LL60382 FT2 TA TUN</p>\n\n<p>Cable is for reference only Contractor may choose appropriate alternate.</p>\n\n<p></p>\n\n<p><strong>Equipment End</strong></p>\n\n<p>Wire Length: 2 Ft</p>\n\n<p>Plug: As marked Amphenol&nbsp; 0935 PT06E-12-3S (SR) 168815001</p>\n\n<p>Cap:&nbsp; As Marked GLENAIR JAN MS3180-12CA 0924</p>\n\n<p>Wire Type: same as Wall Outlet End</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>GFCI Specifications</strong></p>\n\n<p><strong>Common</strong></p>\n\n<p>GROUNDED NEUTRAL: 4 Ohms Typical</p>\n\n<p>VOLTAGE SURGE WITHSTAND: 3 Kv Ringwave Test and 4Kv/2Ka Surge Immunity Test</p>\n\n<p>RADIO FREQUENECY NOISE SUSCEPTABILITY: Operates Within Normal Limits With 0.5 Volts Injected On Power Line 150Khz-230Mhz</p>\n\n<p>ENDURANCE: 3,000 Operations Minimum</p>\n\n<p>OVERLOAD CURRENT: Six Times Rated Current</p>\n\n<p>OPERATING TEMPERATURE RANGE: -35&deg;C to 66&deg;C</p>\n\n<p>EFFECT OF 10 AMP TURN DC SOCK FAULT TRIP: 5% Maximum Trip Level Variation on Ground</p>\n\n<p>INSULATION VOLTAGE: 1500 Vrms - 1 Min.</p>\n\n<p>POWER INDICTATION: Lighted Indicator</p>\n\n<p>Trip Point: Up to 30MA</p>\n\n<p>Trip Response Time: less than 25 MS</p>\n\n<p>Manual Reset</p>\n\n<p></p>\n\n<p>&nbsp;&nbsp;<strong>SPECIFIC To NSN</strong></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9145, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL 120Volt CAGE 1UB81 P/N 0056-1010-01</u></strong></p>\n\n<p><strong><u>For 120 Volt </u></strong></p>\n\n<p>Southwire Model Number 25230001-6 Or equivalent</p>\n\n<p>120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA</p>\n\n<p>See Attachment</p>\n\n<p></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9148, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL&nbsp; 240Volt CAGE 1UB81 P/N 0056-1010-02</u></strong></p>\n\n<p><strong><u>For 240 Volt</u></strong></p>\n\n<p></p>\n\n<p>Southwire Model Number 26000200-6 or equivalent</p>\n\n<p>240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA</p>\n\n<p>See attachment</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Reference Photographs:</strong></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <u>REFERENCE Drawing</u></strong></p>\n\n<p></p>\n\n<p><strong>NSN Specific Data</strong></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9145, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL CAGE 1UB81 P/N 0056-1010-01</u></strong></p>\n\n<p></p>\n\n<p>Must meet the following &nbsp;or equivalent</p>\n\n<p>For 120 Volt</p>\n\n<p>Southwire Model Number 25230001-6 Or equivalent</p>\n\n<p>120V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA</p>\n\n<p>See Attachment</p>\n\n<p></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9148, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL CAGE 1UB81 P/N 0056-1010-02</u></strong></p>\n\n<p></p>\n\n<p>Must meet the following&nbsp; or equivalent</p>\n\n<p>For 240Volt</p>\n\n<p>Southwire Model Number 26000200-6 or equivalent</p>\n\n<p>240V 20A 60Hz Accepts 18 - 12 AWG (SJT) (12 AWG JR cords) YELLOW 4-6mA</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><u>ATTACHMENTS:</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><u>ALTERNATE Southwire Cut Sheet SW-1003814_DL.pdf</u></strong></p>\n\n<p><strong><u>ALTERNATE Southwire Catalog Pages.pdf</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><u>SYSTEM SUPPORTED</u></strong></p>\n\n<p></p>\n\n<p><strong><u>CSS-VSAT AN/TSC-183A</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong><u>WEAPON SYSTEM DIRECTORATE</u></strong></p>\n\n<p></p>\n\n<p><strong><u>&nbsp;&nbsp; C3T&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </u></strong></p>\n\n<p></p>\n\n<p>.</p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>***************************************************************************************</strong></p>\n\n<p></p>\n\n<p>The Defense Logistics Agency-Aberdeen, on behalf of the Army Integrated Logistics Supply Center (ILSC), intends to acquire 500 each <strong><u>NSN&rsquo;s 6150-01-700-9145 and 6150-01-700-9148 </u></strong>to support the Combat Service Support Very Small Apeture Terminal (CSS-VSAT) AN/TSC-183A</p>\n\n<p></p>\n\n<p><u>Items and/or Services to Be Procured:</u></p>\n\n<p></p>\n\n<p><u>Requirements Description:</u></p>\n\n<p></p>\n\n<p>GFCI Cables:</p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9145, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL 120Volt CAGE 1UB81 P/N 0056-1010-01</u></strong></p>\n\n<p></p>\n\n<p><strong><u>NSN&rsquo;s 6150-01-700-9148, </u></strong><strong><u>CABLE ASSEMBLY,POWER,ELECTRICAL&nbsp; 240Volt CAGE 1UB81 P/N 0056-1010-02</u></strong></p>\n\n<p></p>\n\n<p></p>\n\n<p>The Government does not &nbsp;possess the technical data package (TDP) for the parts.</p>\n\n<p></p>\n\n<p>The following additional NAICS apply:<br />\n334220</p>\n\n<p></p>\n\n<p></p>\n\n<p><u>Requested Response Information:</u></p>\n\n<p></p>\n\n<p>We request that sources who can Manufacturing a or supply the listed parts.&nbsp; At a minimum the support information you submit should include, but is not limited to, the following types of documentation: Questionnaire, purchase orders showing your ability to supply either or both of&nbsp; the items listed. Note: TDP is not available.</p>\n\n<p></p>\n\n<p>In your response, please include your company name, CAGE code, and a technical point of contract with email address and telephone number.</p>\n\n<p></p>\n\n<p></p>\n\n<p><u>Notice, Response Due Date, and Points of Contact:</u></p>\n\n<p></p>\n\n<p>This is NOT a Request for Quote or Proposal. The Government does not intend to award a contract on the basis of this SSA or reimburse any costs associated with the preparation of responses to this SSA. This Sources sought announcement (SSA) is for planning and market research purposes only, and shall not be construed as a commitment by the Government. The information gathered from this announcement will be used to determine if responsible sources exist, and to assist in determining if this effort can be competitive and/or set aside for Small Business.&nbsp; Furthermore, the Government will use the information, in part, to determine the best acquisition strategy for a potential procurement action and/or to assist in making acquisition strategy decisions in the future.</p>\n\n<p></p>\n\n<p>All SSA responses should be emailed to the Technical and Competition Advocate Points of Contact at the email addresses listed below. No phone inquiries will be accepted, either as a response to this action or for information requests.&nbsp; All requests for information must be submitted via email to the Technical Point of Contact and the Competition Advocate.</p>\n\n<p></p>\n\n<p>Please submit responses by 01 April 2025</p>\n\n<p></p>\n\n<p>Technical Point of Contact: <strong><u>Kenneth M. Vereb Email: </u></strong><strong>Kenneth.m.vereb2.civ@army.mil</strong><strong><u> Phone 520-674-6033</u></strong></p>\n\n<p></p>\n\n<p><strong>DLA Aberdeen Small Business:</strong> smbizlandcols@dla.mil</p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Kenneth Vereb","role":"primary","email":"kenneth.m.vereb2.civ@army.mil"},{"name":"DLA Land and Maritime SBO","role":"secondary","email":"smbizlandcols@dla.mil"}],"place_of_performance":null,"office_address":{"zip":"21005","city":"ABER PROV GRD","state":"MD","country":"USA"},"naics_codes":["334111"],"award":null,"attachments":[{"resource_id":"4e6db026c5264e54b3d23833356f9e6c","name":"DLA-Aberdeen-25-035-Contractor Questionnaire.docx","kind":"file","mime_type":".docx","size_bytes":16450,"posted_at":"2025-03-14T17:05:07.856Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4e6db026c5264e54b3d23833356f9e6c/download","mirrored":false},{"resource_id":"6f5e5fff657740b58b467c6244d261d3","name":"DLA-Aberdeen-25-035 - Sources Sought CSS_VSAT GFCI CABLES 20250313.docx","kind":"file","mime_type":".docx","size_bytes":299465,"posted_at":"2025-03-14T17:05:07.856Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6f5e5fff657740b58b467c6244d261d3/download","mirrored":false},{"resource_id":"aa8cea541ed54e68b996ddbe4531c4e4","name":"ALTERNATE Southwire Cut Sheet SW-1003814_DL.pdf","kind":"file","mime_type":".pdf","size_bytes":459510,"posted_at":"2025-03-14T17:05:07.856Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/aa8cea541ed54e68b996ddbe4531c4e4/download","mirrored":false},{"resource_id":"e136dd0458e7453ca1c201ee9fc0b7b3","name":"ALTERNATE Southwire Catalog Pages.pdf","kind":"file","mime_type":".pdf","size_bytes":207502,"posted_at":"2025-03-14T17:05:07.856Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e136dd0458e7453ca1c201ee9fc0b7b3/download","mirrored":false}],"awards":[],"related":[{"key":"SPRBL127RA008","latest_notice_id":"4b1e08dfcd644229a5d88766d16edb72","title":"Light Interference Filter (LIF)","solicitation_number":"SPRBL127RA008","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T22:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRBL1","office_name":"DLA LAND AT ABERDEEN","naics":"334290","psc":"5855","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 5855)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"DLAABERDEEN27007","latest_notice_id":"223a06187232421f89384af7a69a4025","title":"Market Survey for Procurement of NSN 7025-01-703-5262 in Support of the Combat Service Support Very Small Aperture Terminal (CSS VSAT) Program","solicitation_number":"DLA-Aberdeen-27-007","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T22:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRBL1","office_name":"DLA LAND AT ABERDEEN","naics":"334290","psc":"7E20","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":"2400175","city_name":"Aberdeen Proving Ground","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SPRBL126RA001","latest_notice_id":"38eea2c7fc6d49808c1d604b65232896","title":"AFOCAL Lens","solicitation_number":"SPRBL126RA001","notice_type":"o","first_type":"p","first_posted":"2026-07-22","last_posted":"2026-11-02","notices":6,"due_at":"2026-12-07T21:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRBL1","office_name":"DLA LAND AT ABERDEEN","naics":"333310","psc":"6650","set_aside":null,"state":"PA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-03T04:52:39.433634Z"},{"key":"SPRBL127QA001","latest_notice_id":"e0bfc72370654da9a9332d48aa3e8d0b","title":"RFQ: SUPPORT, ELECTRIC MOTOR supporting the Common Sensor Payload (CSP)","solicitation_number":"SPRBL127QA001","notice_type":"k","first_type":"k","first_posted":"2026-10-07","last_posted":"2026-10-07","notices":1,"due_at":"2026-12-08T22:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRBL1","office_name":"DLA LAND AT ABERDEEN","naics":"333618","psc":"6105","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":"2400175","city_name":"Aberdeen Proving Ground","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-08T03:46:32.887903Z"},{"key":"DLAABERDEEN27006","latest_notice_id":"9aa19a53c1c44d5fbb77e9648395c801","title":"Market Survey for PVS-14 White Phosphor Image Intensifier Tubes","solicitation_number":"DLA-Aberdeen-27-006","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-10T22:00:00Z","due_date":"2026-12-10","closes_at":"2026-12-10T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRBL1","office_name":"DLA LAND AT ABERDEEN","naics":"334419","psc":"5855","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":"2400175","city_name":"Aberdeen Proving Ground","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open":[{"key":"SPRMM126QKH43","latest_notice_id":"c4bf8e15f6ff4425bcbb6b074b590a77","title":"COMPUTER,TABLET","solicitation_number":"SPRMM126QKH43","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T20:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRMM1","office_name":"SPRMM1 DLA MECHANICSBURG","naics":"334111","psc":"7B22","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7B22)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"SPE7M527U0082","latest_notice_id":"d6e06ef1253849f3bc911b5f1015bcb9","title":"59--ELECTRONIC MODULE,STAN","solicitation_number":"SPE7M527U0082","notice_type":"k","first_type":"k","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M5","office_name":"DLA WEAPONS SUPPORT","naics":"334111","psc":"59","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"NTITY WILL BE 7. ITEMS WILL BE SHIPPED TO VARIOUS CONUS AND OCONUS","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"SPE7M427Q0163","latest_notice_id":"fc0c2bcd00b14fefb6057b14c8d61999","title":"16--MANIFOLD ASSEMBLY,HYDR","solicitation_number":"SPE7M427Q0163","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":null,"due_date":"2026-12-02","closes_at":"2026-12-03T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M4","office_name":"DLA WEAPONS SUPPORT","naics":"334111","psc":"16","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Y,HYDR: LINE 0001 QTY 7 UI EA DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":12,"indexable":false}