{"canonical":"https://sealedbidder.com/opportunities/buckleysfbchillerreplacement","key":"BUCKLEYSFBCHILLERREPLACEMENT","url":"https://sealedbidder.com/opportunities/buckleysfbchillerreplacement","title":"Buckley SFB Chiller Replacement","solicitation_number":"BuckleySFBChillerReplacement","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-22T19:00:00Z","first_posted":"2026-07-14","last_posted":"2026-07-14","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA2543 460 CONS","naics":"238220","psc":"N041","set_aside":"SBA","place_state":"CO","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"08001","place_county_name":"Adams County","place_city":"0804000","place_city_name":"Aurora","winner":null,"award_amount":null,"publications":[{"notice_id":"0da19958a3d44b0799f019dd2bba01f3","title":"Buckley SFB Chiller Replacement","solicitation_number":"BuckleySFBChillerReplacement","notice_type":"r","base_type":"r","posted":"2026-07-14","posted_at":"2026-07-14T16:18:58.621Z","due_at":"2026-07-22T19:00:00Z","due_date":"2026-07-22","cancelled":false,"archived":true,"archive_date":"2026-08-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0da19958a3d44b0799f019dd2bba01f3/view","enriched":true,"history":[{"index":3,"title":"Buckley SFB Chiller Replacement","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T16:18:58.621Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0da19958a3d44b0799f019dd2bba01f3","solicitation_number":"BuckleySFBChillerReplacement"}]}],"latest_notice_id":"0da19958a3d44b0799f019dd2bba01f3","first_type":"r","notices":[{"dates":{"posted":"2026-07-14","posted_at":"2026-07-14T16:18:58.621Z","created_at":"2026-07-14T15:34:45.108Z","modified_at":"2026-08-06T05:06:53.261Z","response_deadline":{"raw":"2026-07-22T13:00:00-06:00","utc":"2026-07-22T19:00:00Z","date":"2026-07-22","time":"13:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0da19958a3d44b0799f019dd2bba01f3/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Buckley SFB Chiller Replacement","agency":{"office":{"code":"FA2543","name":"FA2543 460 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"80011-9572","city":"BUCKLEY AFB","state":"CO","country":"USA"},"organization_id":"100076523","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-06","archive_type":"auto15"},"history":[{"index":3,"title":"Buckley SFB Chiller Replacement","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T16:18:58.621Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0da19958a3d44b0799f019dd2bba01f3","solicitation_number":"BuckleySFBChillerReplacement"}],"contacts":[{"name":"Ethan Sullivan","role":"primary","email":"ethan.sullivan@spaceforce.mil","phone":"7208476446"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"0da19958a3d44b0799f019dd2bba01f3","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"0da19958a3d44b0799f019dd2bba01f3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T03:19:19.077194713Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"2e5696376395260a54978f7ce868208c164a171ec00129ebd741bab4983d8844","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T03:19:19.077194713Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>PLEASE SEE ATTACHMENTS FOR ADDITIONAL INFORMATION REGARDING THIS REQUIREMENT</p>\n\n<p><strong>Notice Type:</strong> Sources Sought <strong>(MARKET RESEARCH PURPOSES ONLY)</strong><br />\n<strong>Title:</strong> Secure Facility Chilled Water System Replacement &ndash; Federal Installation, CO<br />\n<strong>NAICS Code:</strong> 238220 &ndash;&nbsp;Plumbing, Heating, and Air-Conditioning Contractors<br />\n<strong>Product Service Code (PSC):&nbsp;</strong>N041 &ndash; Installation of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment<br />\n<strong>Response Date:</strong> 22 July 2026</p>\n\n<p><strong>Description:</strong></p>\n\n<p>The Department of the Air Force (DAF), on behalf of the Base Civil Engineer Squadron (CES) at a Federal Installation in Colorado, is conducting market research to identify qualified, experienced, and interested business sources&mdash;specifically targeting small and socio-economic businesses (e.g., 8(a), SDVOSB, HUBZone, WOSB)&mdash;capable of performing a complete chilled water system replacement in a 24/7 operations facility.</p>\n\n<p><strong>Project Objective:</strong> The chilled water system serving the facility&#39;s server room currently suffers from degraded serviceability, sub-component failures, and frequent downtime. It is operating at half capacity, which risks the loss of critical cooling for 24/7 operations. The selected contractor must provide all tools, equipment, materials, and certified labor to perform a complete system replacement with zero downtime to the active server room.</p>\n\n<p><strong>Key Scope Items &amp; Technical Specifications:</strong></p>\n\n<ol>\n\t<li>\n\t<p><strong>Design &amp; Sizing:</strong> Perform professional engineering cooling system design load calculations in accordance with UFC 3-410-01 (Sections 2-4 and 2-5.6) to determine final system capacity.</p>\n\t</li>\n\t<li>\n\t<p><strong>Standardization Requirement:</strong> In accordance with the DAF Class Justification and Approval (J&amp;A) for HVAC Chiller Replacement Standardization, the design of the new chiller system must be standardized on <u><strong>Trane-series equipment</strong></u> for this installation.</p>\n\t</li>\n\t<li>\n\t<p><strong>Demolition:</strong> Safely decommission, recover refrigerant from, and remove the existing degraded chiller (Technical Systems Model: 30A0LM20-PT, Serial: 02-17-125822-001-001) and two existing Computer Room Air Handlers (CRAHs) (Data Aire Model: GFCU-04634, Serials: 2016-3226-A, 20163225-A).</p>\n\t</li>\n\t<li>\n\t<p><strong>Equipment Installation:</strong> Procure, install, and commission:</p>\n\n\t<ul>\n\t\t<li>\n\t\t<p>One (1) new <strong>water chiller</strong> with an integrated air-cooled condenser&nbsp;<strong><u>(Trane-series).</u></strong></p>\n\t\t</li>\n\t\t<li>\n\t\t<p>Two (2) new <strong>chilled-water Computer Room Air Handlers (CRAHs)</strong> inside the secure server room.</p>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>\n\t<p><strong>Temporary Cooling:</strong> Provide continuous, redundant temporary cooling to keep the secure server room strictly within operational temperature limits during the transition phase.</p>\n\t</li>\n\t<li>\n\t<p><strong>Controls Integration:</strong> Fully integrate new controls into the base-wide Energy Management Control System (EMCS) in strict compliance with Base EMCS Standards (dated January 21, 2026) and UFC 3-410-02.</p>\n\t</li>\n</ol>\n\n<p><strong>Logistical &amp; Physical Constraints:</strong></p>\n\n<ul>\n\t<li>\n\t<p><strong>Chiller Pad Limits:</strong> The new chiller must fit the existing concrete pad (19&rsquo; - 11&rdquo; L x 12&rsquo;- 8&rdquo; W x 6&rdquo; to 8&rdquo; H) and must not exceed the structural wet weight limit of 12,000 lbs. If the equipment footprint exceeds these limits, the pad must be extended.</p>\n\t</li>\n\t<li>\n\t<p><strong>Rigging &amp; Delivery Clearances:</strong> CRAHs must be navigated through a restricted interior corridor with doorway clearances measuring exactly 34&rdquo; W x 82&rdquo; H.</p>\n\t</li>\n\t<li>\n\t<p><strong>Electrical:</strong> Must integrate with the existing 460V, 60 Hz, 3-Phase power supply and comply with UFC 3-501-01.</p>\n\t</li>\n\t<li>\n\t<p><strong>Security &amp; Clearances:</strong> All personnel must pass NCIC background checks, comply with strict OPSEC guidelines, and complete AT Level I training prior to facility access.</p>\n\t</li>\n</ul>","text":"PLEASE SEE ATTACHMENTS FOR ADDITIONAL INFORMATION REGARDING THIS REQUIREMENT\n\nNotice Type: Sources Sought (MARKET RESEARCH PURPOSES ONLY)\n\nTitle: Secure Facility Chilled Water System Replacement – Federal Installation, CO\n\nNAICS Code: 238220 – Plumbing, Heating, and Air-Conditioning Contractors\n\nProduct Service Code (PSC): N041 – Installation of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment\n\nResponse Date: 22 July 2026\n\nDescription:\n\nThe Department of the Air Force (DAF), on behalf of the Base Civil Engineer Squadron (CES) at a Federal Installation in Colorado, is conducting market research to identify qualified, experienced, and interested business sources—specifically targeting small and socio-economic businesses (e.g., 8(a), SDVOSB, HUBZone, WOSB)—capable of performing a complete chilled water system replacement in a 24/7 operations facility.\n\nProject Objective: The chilled water system serving the facility's server room currently suffers from degraded serviceability, sub-component failures, and frequent downtime. It is operating at half capacity, which risks the loss of critical cooling for 24/7 operations. The selected contractor must provide all tools, equipment, materials, and certified labor to perform a complete system replacement with zero downtime to the active server room.\n\nKey Scope Items & Technical Specifications:\n\n•\nDesign & Sizing: Perform professional engineering cooling system design load calculations in accordance with UFC 3-410-01 (Sections 2-4 and 2-5.6) to determine final system capacity.\n\n•\nStandardization Requirement: In accordance with the DAF Class Justification and Approval (J&A) for HVAC Chiller Replacement Standardization, the design of the new chiller system must be standardized on Trane-series equipment for this installation.\n\n•\nDemolition: Safely decommission, recover refrigerant from, and remove the existing degraded chiller (Technical Systems Model: 30A0LM20-PT, Serial: 02-17-125822-001-001) and two existing Computer Room Air Handlers (CRAHs) (Data Aire Model: GFCU-04634, Serials: 2016-3226-A, 20163225-A).\n\n•\nEquipment Installation: Procure, install, and commission:\n\n•\nOne (1) new water chiller with an integrated air-cooled condenser (Trane-series).\n\n•\nTwo (2) new chilled-water Computer Room Air Handlers (CRAHs) inside the secure server room.\n\n•\nTemporary Cooling: Provide continuous, redundant temporary cooling to keep the secure server room strictly within operational temperature limits during the transition phase.\n\n•\nControls Integration: Fully integrate new controls into the base-wide Energy Management Control System (EMCS) in strict compliance with Base EMCS Standards (dated January 21, 2026) and UFC 3-410-02.\n\nLogistical & Physical Constraints:\n\n•\nChiller Pad Limits: The new chiller must fit the existing concrete pad (19’ - 11” L x 12’- 8” W x 6” to 8” H) and must not exceed the structural wet weight limit of 12,000 lbs. If the equipment footprint exceeds these limits, the pad must be extended.\n\n•\nRigging & Delivery Clearances: CRAHs must be navigated through a restricted interior corridor with doorway clearances measuring exactly 34” W x 82” H.\n\n•\nElectrical: Must integrate with the existing 460V, 60 Hz, 3-Phase power supply and comply with UFC 3-501-01.\n\n•\nSecurity & Clearances: All personnel must pass NCIC background checks, comply with strict OPSEC guidelines, and complete AT Level I training prior to facility access.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"BuckleySFBChillerReplacement","place_of_performance":{"zip":"80011","city":{"code":"4000","name":"Aurora"},"state":{"code":"CO","name":"Colorado"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"N041"}],"due_at":"2026-07-22T19:00:00Z","due_date":"2026-07-22","closes_at":"2026-07-22T19:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA2543","office_name":"FA2543 460 CONS","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-29T03:58:53.462888Z","principal_notice_id":"0da19958a3d44b0799f019dd2bba01f3","description":{"text":"PLEASE SEE ATTACHMENTS FOR ADDITIONAL INFORMATION REGARDING THIS REQUIREMENT\n\nNotice Type: Sources Sought (MARKET RESEARCH PURPOSES ONLY)\n\nTitle: Secure Facility Chilled Water System Replacement – Federal Installation, CO\n\nNAICS Code: 238220 – Plumbing, Heating, and Air-Conditioning Contractors\n\nProduct Service Code (PSC): N041 – Installation of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment\n\nResponse Date: 22 July 2026\n\nDescription:\n\nThe Department of the Air Force (DAF), on behalf of the Base Civil Engineer Squadron (CES) at a Federal Installation in Colorado, is conducting market research to identify qualified, experienced, and interested business sources—specifically targeting small and socio-economic businesses (e.g., 8(a), SDVOSB, HUBZone, WOSB)—capable of performing a complete chilled water system replacement in a 24/7 operations facility.\n\nProject Objective: The chilled water system serving the facility's server room currently suffers from degraded serviceability, sub-component failures, and frequent downtime. It is operating at half capacity, which risks the loss of critical cooling for 24/7 operations. The selected contractor must provide all tools, equipment, materials, and certified labor to perform a complete system replacement with zero downtime to the active server room.\n\nKey Scope Items & Technical Specifications:\n\n•\nDesign & Sizing: Perform professional engineering cooling system design load calculations in accordance with UFC 3-410-01 (Sections 2-4 and 2-5.6) to determine final system capacity.\n\n•\nStandardization Requirement: In accordance with the DAF Class Justification and Approval (J&A) for HVAC Chiller Replacement Standardization, the design of the new chiller system must be standardized on Trane-series equipment for this installation.\n\n•\nDemolition: Safely decommission, recover refrigerant from, and remove the existing degraded chiller (Technical Systems Model: 30A0LM20-PT, Serial: 02-17-125822-001-001) and two existing Computer Room Air Handlers (CRAHs) (Data Aire Model: GFCU-04634, Serials: 2016-3226-A, 20163225-A).\n\n•\nEquipment Installation: Procure, install, and commission:\n\n•\nOne (1) new water chiller with an integrated air-cooled condenser (Trane-series).\n\n•\nTwo (2) new chilled-water Computer Room Air Handlers (CRAHs) inside the secure server room.\n\n•\nTemporary Cooling: Provide continuous, redundant temporary cooling to keep the secure server room strictly within operational temperature limits during the transition phase.\n\n•\nControls Integration: Fully integrate new controls into the base-wide Energy Management Control System (EMCS) in strict compliance with Base EMCS Standards (dated January 21, 2026) and UFC 3-410-02.\n\nLogistical & Physical Constraints:\n\n•\nChiller Pad Limits: The new chiller must fit the existing concrete pad (19’ - 11” L x 12’- 8” W x 6” to 8” H) and must not exceed the structural wet weight limit of 12,000 lbs. If the equipment footprint exceeds these limits, the pad must be extended.\n\n•\nRigging & Delivery Clearances: CRAHs must be navigated through a restricted interior corridor with doorway clearances measuring exactly 34” W x 82” H.\n\n•\nElectrical: Must integrate with the existing 460V, 60 Hz, 3-Phase power supply and comply with UFC 3-501-01.\n\n•\nSecurity & Clearances: All personnel must pass NCIC background checks, comply with strict OPSEC guidelines, and complete AT Level I training prior to facility access.","html":"<p>PLEASE SEE ATTACHMENTS FOR ADDITIONAL INFORMATION REGARDING THIS REQUIREMENT</p>\n\n<p><strong>Notice Type:</strong> Sources Sought <strong>(MARKET RESEARCH PURPOSES ONLY)</strong><br />\n<strong>Title:</strong> Secure Facility Chilled Water System Replacement &ndash; Federal Installation, CO<br />\n<strong>NAICS Code:</strong> 238220 &ndash;&nbsp;Plumbing, Heating, and Air-Conditioning Contractors<br />\n<strong>Product Service Code (PSC):&nbsp;</strong>N041 &ndash; Installation of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment<br />\n<strong>Response Date:</strong> 22 July 2026</p>\n\n<p><strong>Description:</strong></p>\n\n<p>The Department of the Air Force (DAF), on behalf of the Base Civil Engineer Squadron (CES) at a Federal Installation in Colorado, is conducting market research to identify qualified, experienced, and interested business sources&mdash;specifically targeting small and socio-economic businesses (e.g., 8(a), SDVOSB, HUBZone, WOSB)&mdash;capable of performing a complete chilled water system replacement in a 24/7 operations facility.</p>\n\n<p><strong>Project Objective:</strong> The chilled water system serving the facility&#39;s server room currently suffers from degraded serviceability, sub-component failures, and frequent downtime. It is operating at half capacity, which risks the loss of critical cooling for 24/7 operations. The selected contractor must provide all tools, equipment, materials, and certified labor to perform a complete system replacement with zero downtime to the active server room.</p>\n\n<p><strong>Key Scope Items &amp; Technical Specifications:</strong></p>\n\n<ol>\n\t<li>\n\t<p><strong>Design &amp; Sizing:</strong> Perform professional engineering cooling system design load calculations in accordance with UFC 3-410-01 (Sections 2-4 and 2-5.6) to determine final system capacity.</p>\n\t</li>\n\t<li>\n\t<p><strong>Standardization Requirement:</strong> In accordance with the DAF Class Justification and Approval (J&amp;A) for HVAC Chiller Replacement Standardization, the design of the new chiller system must be standardized on <u><strong>Trane-series equipment</strong></u> for this installation.</p>\n\t</li>\n\t<li>\n\t<p><strong>Demolition:</strong> Safely decommission, recover refrigerant from, and remove the existing degraded chiller (Technical Systems Model: 30A0LM20-PT, Serial: 02-17-125822-001-001) and two existing Computer Room Air Handlers (CRAHs) (Data Aire Model: GFCU-04634, Serials: 2016-3226-A, 20163225-A).</p>\n\t</li>\n\t<li>\n\t<p><strong>Equipment Installation:</strong> Procure, install, and commission:</p>\n\n\t<ul>\n\t\t<li>\n\t\t<p>One (1) new <strong>water chiller</strong> with an integrated air-cooled condenser&nbsp;<strong><u>(Trane-series).</u></strong></p>\n\t\t</li>\n\t\t<li>\n\t\t<p>Two (2) new <strong>chilled-water Computer Room Air Handlers (CRAHs)</strong> inside the secure server room.</p>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>\n\t<p><strong>Temporary Cooling:</strong> Provide continuous, redundant temporary cooling to keep the secure server room strictly within operational temperature limits during the transition phase.</p>\n\t</li>\n\t<li>\n\t<p><strong>Controls Integration:</strong> Fully integrate new controls into the base-wide Energy Management Control System (EMCS) in strict compliance with Base EMCS Standards (dated January 21, 2026) and UFC 3-410-02.</p>\n\t</li>\n</ol>\n\n<p><strong>Logistical &amp; Physical Constraints:</strong></p>\n\n<ul>\n\t<li>\n\t<p><strong>Chiller Pad Limits:</strong> The new chiller must fit the existing concrete pad (19&rsquo; - 11&rdquo; L x 12&rsquo;- 8&rdquo; W x 6&rdquo; to 8&rdquo; H) and must not exceed the structural wet weight limit of 12,000 lbs. If the equipment footprint exceeds these limits, the pad must be extended.</p>\n\t</li>\n\t<li>\n\t<p><strong>Rigging &amp; Delivery Clearances:</strong> CRAHs must be navigated through a restricted interior corridor with doorway clearances measuring exactly 34&rdquo; W x 82&rdquo; H.</p>\n\t</li>\n\t<li>\n\t<p><strong>Electrical:</strong> Must integrate with the existing 460V, 60 Hz, 3-Phase power supply and comply with UFC 3-501-01.</p>\n\t</li>\n\t<li>\n\t<p><strong>Security &amp; Clearances:</strong> All personnel must pass NCIC background checks, comply with strict OPSEC guidelines, and complete AT Level I training prior to facility access.</p>\n\t</li>\n</ul>","origin":"detail"},"contacts":[{"name":"Ethan Sullivan","role":"primary","email":"ethan.sullivan@spaceforce.mil","phone":"7208476446"}],"place_of_performance":{"zip":"80011","city":{"code":"4000","name":"Aurora"},"state":{"code":"CO","name":"Colorado"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"80011-9572","city":"BUCKLEY AFB","state":"CO","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"f8104f3bd1e24ea885b1379fa1ec488f","name":"Attachment 1 - SOW - Chiller Replacement - CAO 20 May.pdf","kind":"file","mime_type":".pdf","size_bytes":601525,"posted_at":"2026-07-14T16:18:58.621Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f8104f3bd1e24ea885b1379fa1ec488f/download","mirrored":false}],"awards":[],"related":[{"key":"FA254327Q0003","latest_notice_id":"2aad90d6aa1f4120bfffc544d7899799","title":"BSFB Asbestos Survey Services","solicitation_number":"FA254327Q0003","notice_type":"k","first_type":"k","first_posted":"2026-11-03","last_posted":"2026-11-03","notices":1,"due_at":"2026-12-08T00:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-08T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA2543","office_name":"FA2543 460 CONS","naics":"541620","psc":"F999","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-04T05:14:00.353426Z"}],"similar_open":[{"key":"36C25927Q0048","latest_notice_id":"c63e9c1e32f4475caa79c878ba87ca2f","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W911PT27QA020","latest_notice_id":"084d5efc5ec44a9885a37b90e6705ffa","title":"REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS","solicitation_number":"W911PT27QA020","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"238220","psc":"Z2NB","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"IGH VELOCITY AIR HANDLING UNITSPROJECT LOCATION: WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"}],"similar_open_total":59,"indexable":false}