{"canonical":"https://sealedbidder.com/opportunities/b548460cd80e47a6b340a1baa07b568f","key":"B548460CD80E47A6B340A1BAA07B568F","url":"https://sealedbidder.com/opportunities/b548460cd80e47a6b340a1baa07b568f","title":"Precision Shaker Spectrometer","solicitation_number":null,"notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-06-23T16:00:00Z","first_posted":"2025-06-16","last_posted":"2025-06-16","department":"COMMERCE, DEPARTMENT OF","subagency":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6695","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":"2431175","place_city_name":"Gaithersburg","winner":null,"award_amount":null,"publications":[{"notice_id":"abd8f7a5085748e3a39180705d5b208e","title":"Precision Shaker Spectrometer","solicitation_number":null,"notice_type":"s","base_type":"r","posted":"2025-06-16","posted_at":"2025-06-16T16:02:19.199Z","due_at":"2025-06-23T16:00:00Z","due_date":"2025-06-23","cancelled":false,"archived":true,"archive_date":"2025-07-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/abd8f7a5085748e3a39180705d5b208e/view","enriched":true,"history":[{"index":6,"title":"Precision Shaker Spectrometer","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-16T16:02:19.199Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"abd8f7a5085748e3a39180705d5b208e","related_opportunity_id":"b548460cd80e47a6b340a1baa07b568f"},{"index":4,"title":"Precision Shaker Spectrometer","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-04T23:21:33.231Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b548460cd80e47a6b340a1baa07b568f","solicitation_number":"NIST-SS25-50"}]}],"latest_notice_id":"abd8f7a5085748e3a39180705d5b208e","first_type":"s","notices":[{"dates":{"posted":"2025-06-16","posted_at":"2025-06-16T16:02:19.199Z","created_at":"2025-06-16T15:59:01.622Z","modified_at":"2025-07-09T04:00:08.248Z","response_deadline":{"raw":"2025-06-23T12:00:00-04:00","utc":"2025-06-23T16:00:00Z","date":"2025-06-23","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/abd8f7a5085748e3a39180705d5b208e/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Precision Shaker Spectrometer","agency":{"office":{"code":"1333ND","name":"DEPT OF COMMERCE NIST"},"subtier":{"code":"1341","name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY"},"department":{"code":"013","name":"COMMERCE, DEPARTMENT OF"},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"organization_id":"100182905","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-08","archive_type":"auto15"},"history":[{"index":6,"title":"Precision Shaker Spectrometer","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-16T16:02:19.199Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"abd8f7a5085748e3a39180705d5b208e","related_opportunity_id":"b548460cd80e47a6b340a1baa07b568f"},{"index":4,"title":"Precision Shaker Spectrometer","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-04T23:21:33.231Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b548460cd80e47a6b340a1baa07b568f","solicitation_number":"NIST-SS25-50"}],"contacts":[{"name":"Cielo Ibarra","role":"primary","email":"cielo.ibarra@nist.gov"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"abd8f7a5085748e3a39180705d5b208e","lineage_id":"b548460cd80e47a6b340a1baa07b568f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T12:53:34.983234789Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"5075f921484f9c5de0fdb89ffb731a3e664046be0cc83845f0860565ec09c670","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-12T12:53:34.983234789Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>Announcement Type</strong>: Special Notice<br />\n<strong>Classification Code: </strong>6695</p>\n\n<p><strong>Announcement Number:</strong> NB305000-25-00924</p>\n\n<p><strong>Subject:</strong> Notice of Intent to Noncompetitively Acquire Precision Shaker Spectrometer</p>\n\n<p>This notice is not a request for a quotation. A solicitation document will not be issued and quotations will not be requested.</p>\n\n<p>This acquisition is being conducted under the authority of FAR 13.106-1(b) via FAR 13.106-1(b). The North American Industry Classification System (NAICS) code for this acquisition is 334516, Analytical Laboratory Instrument Manufacturing.</p>\n\n<p>The Physical Measurement Laboratory at NIST develops advanced sensors to measure acceleration. As part of this work a shaker (also called a vibrational exciter system) is required to test photonic accelerometers. Specifically, we require a shaker that: 1) will operate vertically, 2) includes an internal reference accelerometer, 3) is fully compatible with our current system that uses a Spektra model SE-29 shaker, and 4) meets or exceeds the performance of the SE-29. The system will include the shaker, the amplifier to run it, the internal reference accelerometer, and the signal conditioning electronics to read it, as well as all cables and accessories required to operate the system with an accelerometer mounted. After thorough evaluation, it has been determined that the Precision Shaker Spectrometer from manufacturer, Spektra dba APS Dynamics, is essential for several reasons:</p>\n\n<ol>\n\t<li><strong>Compatibility</strong>: The new shaker must be a drop-in replacement for the existing shaker system to allow interoperability with the acceleration measurement and data acquisition NIST has developed. NIST has put a considerable amount of time and investment into developing the acceleration and data acquisition on the existing shaker system. These measurements are custom-designed for the Spektra SE-29 and is not compatible with any other shaker systems. Working another shaker system than the Spektra SE-29 would require a large undertaking (in both time and investment) by the Government and will not result in performance required by NIST to conduct its research.</li>\n\t<li><strong>Technical:</strong> The new shaker must be highly precise but not use air bearings in order to avoid the low-frequency noise associated with air flow that interferes with low-frequency measurements required for inertail navigation measurements. Market research reveals no other precision shakers have the performance specifications higher than the Spektra SE-29 specifications which are needed to meet our requirements.</li>\n</ol>\n\n<p><br />\nNIST conducted market research from April 2025 - June 2025 by internet searches, discussions with sources, and a sources sought posting. Sources sought NIST-SS25-50 was posted from June 4, 2025, through June 11, 2025, with one response received from Spektra. The results of that market research revealed that only Spektra dba APS Dynamics, Inc. 32124 PASEO ADELANTO STE 3, SAN JUAN CAPISTRANO, CA 92675 USA, UEI: J759DW8FBCN7 appears to be capable of meeting NIST&rsquo;s requirements.</p>\n\n<p>However, any sources that believe they are capable of meeting NIST&rsquo;s minimum requirements are encouraged to respond to this notice by the response date to provide the following information at a minimum: Company Unique Entity Identifier number in https://sam.gov; details about what your company is capable of providing that meets or exceeds NIST&rsquo;s minimum requirements; whether your company is an authorized reseller of the product or service being cited and evidence of such authorization; and any other information that can help NIST determine whether this requirement may be competitively satisfied.&nbsp;</p>","text":"Announcement Type: Special Notice\n\nClassification Code: 6695\n\nAnnouncement Number: NB305000-25-00924\n\nSubject: Notice of Intent to Noncompetitively Acquire Precision Shaker Spectrometer\n\nThis notice is not a request for a quotation. A solicitation document will not be issued and quotations will not be requested.\n\nThis acquisition is being conducted under the authority of FAR 13.106-1(b) via FAR 13.106-1(b). The North American Industry Classification System (NAICS) code for this acquisition is 334516, Analytical Laboratory Instrument Manufacturing.\n\nThe Physical Measurement Laboratory at NIST develops advanced sensors to measure acceleration. As part of this work a shaker (also called a vibrational exciter system) is required to test photonic accelerometers. Specifically, we require a shaker that: 1) will operate vertically, 2) includes an internal reference accelerometer, 3) is fully compatible with our current system that uses a Spektra model SE-29 shaker, and 4) meets or exceeds the performance of the SE-29. The system will include the shaker, the amplifier to run it, the internal reference accelerometer, and the signal conditioning electronics to read it, as well as all cables and accessories required to operate the system with an accelerometer mounted. After thorough evaluation, it has been determined that the Precision Shaker Spectrometer from manufacturer, Spektra dba APS Dynamics, is essential for several reasons:\n\n• Compatibility: The new shaker must be a drop-in replacement for the existing shaker system to allow interoperability with the acceleration measurement and data acquisition NIST has developed. NIST has put a considerable amount of time and investment into developing the acceleration and data acquisition on the existing shaker system. These measurements are custom-designed for the Spektra SE-29 and is not compatible with any other shaker systems. Working another shaker system than the Spektra SE-29 would require a large undertaking (in both time and investment) by the Government and will not result in performance required by NIST to conduct its research.\n\n• Technical: The new shaker must be highly precise but not use air bearings in order to avoid the low-frequency noise associated with air flow that interferes with low-frequency measurements required for inertail navigation measurements. Market research reveals no other precision shakers have the performance specifications higher than the Spektra SE-29 specifications which are needed to meet our requirements.\n\nNIST conducted market research from April 2025 - June 2025 by internet searches, discussions with sources, and a sources sought posting. Sources sought NIST-SS25-50 was posted from June 4, 2025, through June 11, 2025, with one response received from Spektra. The results of that market research revealed that only Spektra dba APS Dynamics, Inc. 32124 PASEO ADELANTO STE 3, SAN JUAN CAPISTRANO, CA 92675 USA, UEI: J759DW8FBCN7 appears to be capable of meeting NIST’s requirements.\n\nHowever, any sources that believe they are capable of meeting NIST’s minimum requirements are encouraged to respond to this notice by the response date to provide the following information at a minimum: Company Unique Entity Identifier number in https://sam.gov; details about what your company is capable of providing that meets or exceeds NIST’s minimum requirements; whether your company is an authorized reseller of the product or service being cited and evidence of such authorization; and any other information that can help NIST determine whether this requirement may be competitively satisfied.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"place_of_performance":{"zip":"20899","city":{"code":"31175","name":"Gaithersburg"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6695"}],"due_at":"2025-06-23T16:00:00Z","due_date":"2025-06-23","closes_at":"2025-06-23T16:00:00Z","awardable":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-13T05:18:31.697344Z","principal_notice_id":"abd8f7a5085748e3a39180705d5b208e","description":{"text":"Announcement Type: Special Notice\n\nClassification Code: 6695\n\nAnnouncement Number: NB305000-25-00924\n\nSubject: Notice of Intent to Noncompetitively Acquire Precision Shaker Spectrometer\n\nThis notice is not a request for a quotation. A solicitation document will not be issued and quotations will not be requested.\n\nThis acquisition is being conducted under the authority of FAR 13.106-1(b) via FAR 13.106-1(b). The North American Industry Classification System (NAICS) code for this acquisition is 334516, Analytical Laboratory Instrument Manufacturing.\n\nThe Physical Measurement Laboratory at NIST develops advanced sensors to measure acceleration. As part of this work a shaker (also called a vibrational exciter system) is required to test photonic accelerometers. Specifically, we require a shaker that: 1) will operate vertically, 2) includes an internal reference accelerometer, 3) is fully compatible with our current system that uses a Spektra model SE-29 shaker, and 4) meets or exceeds the performance of the SE-29. The system will include the shaker, the amplifier to run it, the internal reference accelerometer, and the signal conditioning electronics to read it, as well as all cables and accessories required to operate the system with an accelerometer mounted. After thorough evaluation, it has been determined that the Precision Shaker Spectrometer from manufacturer, Spektra dba APS Dynamics, is essential for several reasons:\n\n• Compatibility: The new shaker must be a drop-in replacement for the existing shaker system to allow interoperability with the acceleration measurement and data acquisition NIST has developed. NIST has put a considerable amount of time and investment into developing the acceleration and data acquisition on the existing shaker system. These measurements are custom-designed for the Spektra SE-29 and is not compatible with any other shaker systems. Working another shaker system than the Spektra SE-29 would require a large undertaking (in both time and investment) by the Government and will not result in performance required by NIST to conduct its research.\n\n• Technical: The new shaker must be highly precise but not use air bearings in order to avoid the low-frequency noise associated with air flow that interferes with low-frequency measurements required for inertail navigation measurements. Market research reveals no other precision shakers have the performance specifications higher than the Spektra SE-29 specifications which are needed to meet our requirements.\n\nNIST conducted market research from April 2025 - June 2025 by internet searches, discussions with sources, and a sources sought posting. Sources sought NIST-SS25-50 was posted from June 4, 2025, through June 11, 2025, with one response received from Spektra. The results of that market research revealed that only Spektra dba APS Dynamics, Inc. 32124 PASEO ADELANTO STE 3, SAN JUAN CAPISTRANO, CA 92675 USA, UEI: J759DW8FBCN7 appears to be capable of meeting NIST’s requirements.\n\nHowever, any sources that believe they are capable of meeting NIST’s minimum requirements are encouraged to respond to this notice by the response date to provide the following information at a minimum: Company Unique Entity Identifier number in https://sam.gov; details about what your company is capable of providing that meets or exceeds NIST’s minimum requirements; whether your company is an authorized reseller of the product or service being cited and evidence of such authorization; and any other information that can help NIST determine whether this requirement may be competitively satisfied.","html":"<p><strong>Announcement Type</strong>: Special Notice<br />\n<strong>Classification Code: </strong>6695</p>\n\n<p><strong>Announcement Number:</strong> NB305000-25-00924</p>\n\n<p><strong>Subject:</strong> Notice of Intent to Noncompetitively Acquire Precision Shaker Spectrometer</p>\n\n<p>This notice is not a request for a quotation. A solicitation document will not be issued and quotations will not be requested.</p>\n\n<p>This acquisition is being conducted under the authority of FAR 13.106-1(b) via FAR 13.106-1(b). The North American Industry Classification System (NAICS) code for this acquisition is 334516, Analytical Laboratory Instrument Manufacturing.</p>\n\n<p>The Physical Measurement Laboratory at NIST develops advanced sensors to measure acceleration. As part of this work a shaker (also called a vibrational exciter system) is required to test photonic accelerometers. Specifically, we require a shaker that: 1) will operate vertically, 2) includes an internal reference accelerometer, 3) is fully compatible with our current system that uses a Spektra model SE-29 shaker, and 4) meets or exceeds the performance of the SE-29. The system will include the shaker, the amplifier to run it, the internal reference accelerometer, and the signal conditioning electronics to read it, as well as all cables and accessories required to operate the system with an accelerometer mounted. After thorough evaluation, it has been determined that the Precision Shaker Spectrometer from manufacturer, Spektra dba APS Dynamics, is essential for several reasons:</p>\n\n<ol>\n\t<li><strong>Compatibility</strong>: The new shaker must be a drop-in replacement for the existing shaker system to allow interoperability with the acceleration measurement and data acquisition NIST has developed. NIST has put a considerable amount of time and investment into developing the acceleration and data acquisition on the existing shaker system. These measurements are custom-designed for the Spektra SE-29 and is not compatible with any other shaker systems. Working another shaker system than the Spektra SE-29 would require a large undertaking (in both time and investment) by the Government and will not result in performance required by NIST to conduct its research.</li>\n\t<li><strong>Technical:</strong> The new shaker must be highly precise but not use air bearings in order to avoid the low-frequency noise associated with air flow that interferes with low-frequency measurements required for inertail navigation measurements. Market research reveals no other precision shakers have the performance specifications higher than the Spektra SE-29 specifications which are needed to meet our requirements.</li>\n</ol>\n\n<p><br />\nNIST conducted market research from April 2025 - June 2025 by internet searches, discussions with sources, and a sources sought posting. Sources sought NIST-SS25-50 was posted from June 4, 2025, through June 11, 2025, with one response received from Spektra. The results of that market research revealed that only Spektra dba APS Dynamics, Inc. 32124 PASEO ADELANTO STE 3, SAN JUAN CAPISTRANO, CA 92675 USA, UEI: J759DW8FBCN7 appears to be capable of meeting NIST&rsquo;s requirements.</p>\n\n<p>However, any sources that believe they are capable of meeting NIST&rsquo;s minimum requirements are encouraged to respond to this notice by the response date to provide the following information at a minimum: Company Unique Entity Identifier number in https://sam.gov; details about what your company is capable of providing that meets or exceeds NIST&rsquo;s minimum requirements; whether your company is an authorized reseller of the product or service being cited and evidence of such authorization; and any other information that can help NIST determine whether this requirement may be competitively satisfied.&nbsp;</p>","origin":"detail"},"contacts":[{"name":"Cielo Ibarra","role":"primary","email":"cielo.ibarra@nist.gov"}],"place_of_performance":{"zip":"20899","city":{"code":"31175","name":"Gaithersburg"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[],"awards":[],"related":[{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"NISTSS26CHIPS13","latest_notice_id":"0124b2bd52b742b8a14350289fc0626d","title":"Sources Sought Notice for Mid-IR Optical Frequency Comb","solicitation_number":"NIST-SS26-CHIPS-13","notice_type":"r","first_type":"r","first_posted":"2025-11-19","last_posted":"2025-11-19","notices":1,"due_at":"2026-12-03T22:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"573067270009","latest_notice_id":"ff7a062def984637aae7109d5026d17c","title":"Sources Sought: Polarization-Entangled Photon Source","solicitation_number":"573067-27-0009","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6035","set_aside":null,"state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"NISTSS26CHIPS16","latest_notice_id":"f06db812fc2549fc995d22d26b2dbc5c","title":"Sources Sought Notice for Continuous Wave Parametric Oscillator (CW OPO) Laser System","solicitation_number":"NIST-SS26-CHIPS-16","notice_type":"r","first_type":"r","first_posted":"2025-11-20","last_posted":"2025-11-20","notices":1,"due_at":"2026-12-05T16:00:00Z","due_date":"2026-12-05","closes_at":"2026-12-05T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"1333ND27R0001","latest_notice_id":"bb1373be92d643798f65aae817d7aba0","title":"CUP Preventative Maintenance and Repair, NIST, Boulder, CO","solicitation_number":"1333ND27R0001","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-09T22:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"811310","psc":"Z1JZ","set_aside":"SBA","state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":53,"indexable":false}