Sources sought, total small business set-aside
122FW - Fort Wayne, IN - Bldg. 770 Fire Crash/Rescue Station Addition/Alteration
ATQZ229030
Department of the Army, W7M7 Uspfo Activity Inang 122. Commercial and Institutional Building Construction.
Response deadline
November 28, 2025 at 5:00 PM EST
Closed 362 days ago. Posted November 18, 2025. Scheduled to archive December 13, 2025.
Get the next one like this from Department of the Army by email, the day it is posted.Find my opportunities
This one closed in 2025
188 like it are open now in commercial and institutional building construction
- Barillas Peak & Encino Vista Lookout Tower Restoration, Santa Fe NF
Forest Service, Usda-Fs, Csa Southwest 7
Combined synopsis and solicitationSmall businessNAICS 236220Santa Fe, NM127EAX26Q0069Due todayNov 25 - 654-24-004 | Remediate Old Parking Garage
Department of Veterans Affairs, 261-Network Contract Office 21
SolicitationSDVOSBNAICS 236220Reno, NV36C26126Q1297Due todayNov 25 - Request for Qualification - MHMV230026 Construct Permanent Party Enlisted Dorm at Kirtland AFB, New Mexico
Department of the Air Force, FA9401 377 MSG PK
SolicitationNAICS 236220New MexicoFA940127R0001Due todayNov 25
All 188 open in commercial and institutional building construction
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- Total small business set-aside. Only small businesses may compete. Small, under NAICS 236220 (commercial and institutional building construction), means no more than $45 million in average annual receipts, counted with affiliates. Open Small business opportunities
- What comes next
- No solicitation was published under this number after the sources sought of November 18, 2025. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
THIS IS A SOURCES SOUGHT POSTING. This is NOT a solicitation, but market research to determine potential sources for this project including interested small business sources. This notice is for planning purposes only.
Not responding to this Sources Sought does not preclude participation in any future solicitation, should one be issued. It is the responsibility of the interested parties to monitor the SAM.gov website for additional information pertaining to this Sources Sought.
A Sources Sought posting was originally posted on February 4, 2025, as notice ID W50S7W-25-B-A001. Plans and Specifications associated with the project were redrafted and the project was not solicited. Due to the length of time that has elapsed, a new Sources Sought is being posted to redetermine interested potential sources.
The purpose of this requirement is to renovate and construct an addition to existing Fire Crash/Rescue station, building 770, located at the 122d Fighter Wing in Fort Wayne, IN using government provided designs/specs/drawings. The project includes repair/renovation of the roof, lightning protection, exterior envelope, fire protection system, and HVAC systems. This project involves substantial renovations to the existing single-story CMU, 10,664 sqft station building. Additionally, the project will construct two structurally independent CMU additions: a 2,310 sqft apparatus bay and a 4,630 sqft administrative and dormitory area. The project includes:
- Construction of an ICC 500-2020 storm shelter
- Sustainability tracking and submittals throughout the project
- Supporting infrastructure to facilitate the installation of a Monaco D-21 central fire alarm monitoring system
- Construction of two structurally independent additions to an existing facility
Installation of a new sprinkler (no sprinkler system exists in the current building) and alarm system throughout the existing building and new additions.
Response INFORMATION:
The magnitude of this project will be between $5,000,000 and $10,000,000. Interested concerns will provide this office, in writing via single PDF, with a notice stating their positive intent to submit a bid as a prime contractor no later than 28 NOV 2025 at 5:00PM EST.
This notification, which shall not exceed seven typewritten pages (not inclusive of attachments), must include:
(1) Positive statement of intent to bid as a prime contractor
(2) Completed Sources Sought Response Form
Responses may include information on projects completed during the past three years of a similar scope, both for government and private industry. Including: Type of project, Price, Contract number, Location, Customer and Customer and customer point of contact.
In the event adequate Small Business contractors are not available for adequate competition for this project, it may be advertised as unrestricted.
Information shall be provided via emails to both: lisa.crose@us.af.mil & travis.kraick@us.af.mil
Include in the subject line: Sources Sought_B770 FIRE STATION_Company Name
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Sources Sought Response Form.pdf161 KB, November 18, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
November 18, 2025
Sources sought
Due November 28, 2025 at 5:00 PM EST. SAM.gov, notice 99071a3c196a48079d25db44e9cfcfe5
2 revisions on SAM
- February 27, 2026: publish, presolicitation
- November 18, 2025: publish, sources sought
Points of contact
- Lisa Croselisa.crose@us.af.mil2604783265