{"canonical":"https://sealedbidder.com/opportunities/a24007","key":"A24007","url":"https://sealedbidder.com/opportunities/a24007","title":"Water Cooled X-Ray System","solicitation_number":"A24-007","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-06-04T15:00:00Z","first_posted":"2025-05-29","last_posted":"2025-05-29","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA8125 AFSC PZIMA","naics":"334519","psc":"6680","set_aside":"SBA","place_state":"OK","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"40109","place_county_name":"Oklahoma County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"baf436a0bbc54782ad278478ae94cd8a","title":"Water Cooled X-Ray System","solicitation_number":"A24-007","notice_type":"p","base_type":"p","posted":"2025-05-29","posted_at":"2025-05-29T20:46:45.707Z","due_at":"2025-06-04T15:00:00Z","due_date":"2025-06-04","cancelled":false,"archived":true,"archive_date":"2025-06-19","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/baf436a0bbc54782ad278478ae94cd8a/view","enriched":true,"history":[{"index":6,"title":"Water Cooled X-Ray System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T01:11:12.654Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"44df992b0ec4423c8fe567f5888b909e","solicitation_number":"FA8125-25-Q-0082","related_opportunity_id":"baf436a0bbc54782ad278478ae94cd8a"},{"index":4,"title":"Water Cooled X-Ray System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-29T20:46:45.707Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"baf436a0bbc54782ad278478ae94cd8a","solicitation_number":"A24-007"}]}],"latest_notice_id":"baf436a0bbc54782ad278478ae94cd8a","first_type":"p","notices":[{"dates":{"posted":"2025-05-29","posted_at":"2025-05-29T20:46:45.707Z","created_at":"2025-05-29T20:43:52.329Z","modified_at":"2025-06-19T04:04:38.514Z","response_deadline":{"raw":"2025-06-04T10:00:00-05:00","utc":"2025-06-04T15:00:00Z","date":"2025-06-04","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/baf436a0bbc54782ad278478ae94cd8a/view"},"naics":{"codes":["334519"],"primary":"334519"},"title":"Water Cooled X-Ray System","agency":{"office":{"code":"FA8125","name":"FA8125 AFSC PZIMA"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"73145-3303","city":"TINKER AFB","state":"OK","country":"USA"},"organization_id":"500020988","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-19","archive_type":"auto15"},"history":[{"index":6,"title":"Water Cooled X-Ray System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-13T01:11:12.654Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"44df992b0ec4423c8fe567f5888b909e","solicitation_number":"FA8125-25-Q-0082","related_opportunity_id":"baf436a0bbc54782ad278478ae94cd8a"},{"index":4,"title":"Water Cooled X-Ray System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-29T20:46:45.707Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"baf436a0bbc54782ad278478ae94cd8a","solicitation_number":"A24-007"}],"contacts":[{"name":"Sondra Groth","role":"primary","email":"Sondra.Groth@us.af.mil"},{"name":"Sheridan Robison","role":"secondary","email":"sheridan.robison@us.af.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"baf436a0bbc54782ad278478ae94cd8a","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"baf436a0bbc54782ad278478ae94cd8a","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-13T11:25:57.270589639Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"260fa0fceca9a3cd92e7c3d66886204ce18c296d591b0bf2277b56ea98b51a76","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-13T11:25:57.270589639Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>The Air Force intends to solicit the following supply:</p>\n\n<p></p>\n\n<p>76 AMXG is requesting utilization of funds for Request for the purchase of 4 ea.</p>\n\n<p>Water Cooled Xray System to include the following:</p>\n\n<p>Input Line Requirements:</p>\n\n<ul>\n\t<li>Automatically adapts to input line voltage100-130Vac, 50/60Hz, 20 Amperes maximum.</li>\n\t<li>200-250Vac, 50/60Hz, 10 Amperes maximum</li>\n\t<li>20 to 160kV, 0.5mA to 5.0mA (800 watts max.)</li>\n\t<li>Constant potential, end-grounded anode, liquid cooled version</li>\n</ul>\n\n<p>X-Ray Tube Window:</p>\n\n<ul>\n\t<li>Beryllium 0.8mm (directional) 40&deg; directional</li>\n</ul>\n\n<p>Radiation Output:</p>\n\n<ul>\n\t<li>14R/min at 50cm filtered with 0.5 inches (12.7mm)</li>\n\t<li>Aluminum at 160kV, 5mA</li>\n</ul>\n\n<p>Radiation Leakage:</p>\n\n<ul>\n\t<li>Less than 2.0 Roentgens per hour at 1 meter from the X-Raytube target</li>\n</ul>\n\n<ul>\n\t<li>Effective Focal Spot: Standard: 0.7mm x 1.0mm (0.03in x 0.04in) EN125430.5mm x 0.5mm (0.02in x 0.02in) nominal IEC60336</li>\n</ul>\n\n<p>Ambient Temp:</p>\n\n<ul>\n\t<li>100% duty cycle @ 120&deg;F (49&deg;C)</li>\n</ul>\n\n<ul>\n\t<li>Duty Cycle: 100%</li>\n</ul>\n\n<p>Storage Temp:</p>\n\n<ul>\n\t<li>-30&deg;F to 160&deg;F (-35&deg;C to 71&deg;C)</li>\n</ul>\n\n<p>Anode Cooling:</p>\n\n<ul>\n\t<li>Liquid coolant solution closed loop between X-Ray tube anode and cooling unit.</li>\n\t<li>Liquid Cooling Unit Weight: 54lbs. (15.4kg) approx.</li>\n\t<li>Tube Head Dimensions: No greater than 7.25&quot; Diameter, 30&quot; Length</li>\n\t<li>Liquid Cooled: 29lbs. (13.15kg)</li>\n</ul>\n\n<p>X-Ray Control Unit:</p>\n\n<ul>\n\t<li>X-Ray Control Unit Weight: 26lbs. (11.8kg) approx</li>\n</ul>\n\n<p>Safety Devices:</p>\n\n<ul>\n\t<li>Tubehead Pressure Relief Valve</li>\n\t<li>Tubehead Thermal Cut-Out</li>\n\t<li>Tubehead Pressure Gauge</li>\n\t<li>Tubehead Low Pressure Cut-Out @ 25psi (1.72 Bar)</li>\n\t<li>Coolant Flow Sensor (liquid cooled only)</li>\n\t<li>Control Unit Safety Keyswitch</li>\n\t<li>Microcomputer-based Self Diagnostics</li>\n\t<li>Continuous Exposure Parameter Display</li>\n</ul>\n\n<p>Standard Accessories:</p>\n\n<ul>\n\t<li>Operation manual</li>\n\t<li>Tubehead carrying case</li>\n\t<li>Tubehead Cable- 100&rsquo; with strain relief</li>\n\t<li>Extra key (1) for Control Unit Safety Lock</li>\n\t<li>Power cable - 25&rsquo; with strain relief</li>\n\t<li>Coolant hose - twin, 50&rsquo; with self-sealing terminations</li>\n\t<li>(liquid cooled only)</li>\n\t<li>Cooler power cable</li>\n\t<li>GUI Control Software for the GUI is specifically designed for controlling series systems. As an alternative to the front panel control, the GUI will allow the user to control all necessary functions of the system from a user-friendly windows-based menu. Additionally, the GUI can be used as a diagnostic tool when the system is controlled via the front panel.</li>\n</ul>\n\n<p></p>\n\n<p>A Firm Fixed Price type contract is contemplated.</p>\n\n<p></p>\n\n<p>Estimated Period of Performance: &nbsp;360 days ARO</p>\n\n<p></p>\n\n<p>This is a small business set-aside</p>\n\n<p></p>\n\n<p>System for Award Management (SAM) is required to receive any award. Contractors can register electronically at https://www.sam.gov/portal/public/SAM/. The NAICS code for this requirement is 334519 with a size standard of 600 EMP.</p>\n\n<p></p>\n\n<p>Interested persons may identify their interest and capability to respond to the requirement by submitting a proposal. Electronic procedures will be used for this solicitation through Beta.sam.gov at https://sam.gov/content/home.&nbsp; No telephone requests. See Note 22. Authority is 10 USC 2304 (c)(1).</p>\n\n<p></p>\n\n<p>For further information contact:</p>\n\n<p>Sondra Groth</p>\n\n<p>Contracting Specialist</p>\n\n<p>Sondra.groth@us.af.mil</p>","text":"The Air Force intends to solicit the following supply:\n\n76 AMXG is requesting utilization of funds for Request for the purchase of 4 ea.\n\nWater Cooled Xray System to include the following:\n\nInput Line Requirements:\n\n• Automatically adapts to input line voltage100-130Vac, 50/60Hz, 20 Amperes maximum.\n\n• 200-250Vac, 50/60Hz, 10 Amperes maximum\n\n• 20 to 160kV, 0.5mA to 5.0mA (800 watts max.)\n\n• Constant potential, end-grounded anode, liquid cooled version\n\nX-Ray Tube Window:\n\n• Beryllium 0.8mm (directional) 40° directional\n\nRadiation Output:\n\n• 14R/min at 50cm filtered with 0.5 inches (12.7mm)\n\n• Aluminum at 160kV, 5mA\n\nRadiation Leakage:\n\n• Less than 2.0 Roentgens per hour at 1 meter from the X-Raytube target\n\n• Effective Focal Spot: Standard: 0.7mm x 1.0mm (0.03in x 0.04in) EN125430.5mm x 0.5mm (0.02in x 0.02in) nominal IEC60336\n\nAmbient Temp:\n\n• 100% duty cycle @ 120°F (49°C)\n\n• Duty Cycle: 100%\n\nStorage Temp:\n\n• -30°F to 160°F (-35°C to 71°C)\n\nAnode Cooling:\n\n• Liquid coolant solution closed loop between X-Ray tube anode and cooling unit.\n\n• Liquid Cooling Unit Weight: 54lbs. (15.4kg) approx.\n\n• Tube Head Dimensions: No greater than 7.25\" Diameter, 30\" Length\n\n• Liquid Cooled: 29lbs. (13.15kg)\n\nX-Ray Control Unit:\n\n• X-Ray Control Unit Weight: 26lbs. (11.8kg) approx\n\nSafety Devices:\n\n• Tubehead Pressure Relief Valve\n\n• Tubehead Thermal Cut-Out\n\n• Tubehead Pressure Gauge\n\n• Tubehead Low Pressure Cut-Out @ 25psi (1.72 Bar)\n\n• Coolant Flow Sensor (liquid cooled only)\n\n• Control Unit Safety Keyswitch\n\n• Microcomputer-based Self Diagnostics\n\n• Continuous Exposure Parameter Display\n\nStandard Accessories:\n\n• Operation manual\n\n• Tubehead carrying case\n\n• Tubehead Cable- 100’ with strain relief\n\n• Extra key (1) for Control Unit Safety Lock\n\n• Power cable - 25’ with strain relief\n\n• Coolant hose - twin, 50’ with self-sealing terminations\n\n• (liquid cooled only)\n\n• Cooler power cable\n\n• GUI Control Software for the GUI is specifically designed for controlling series systems. As an alternative to the front panel control, the GUI will allow the user to control all necessary functions of the system from a user-friendly windows-based menu. Additionally, the GUI can be used as a diagnostic tool when the system is controlled via the front panel.\n\nA Firm Fixed Price type contract is contemplated.\n\nEstimated Period of Performance: 360 days ARO\n\nThis is a small business set-aside\n\nSystem for Award Management (SAM) is required to receive any award. Contractors can register electronically at https://www.sam.gov/portal/public/SAM/. The NAICS code for this requirement is 334519 with a size standard of 600 EMP.\n\nInterested persons may identify their interest and capability to respond to the requirement by submitting a proposal. Electronic procedures will be used for this solicitation through Beta.sam.gov at https://sam.gov/content/home. No telephone requests. See Note 22. Authority is 10 USC 2304 (c)(1).\n\nFor further information contact:\n\nSondra Groth\n\nContracting Specialist\n\nSondra.groth@us.af.mil","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"A24-007","place_of_performance":{"zip":"73145","city":{"code":"0","name":"Tinker AFB"},"state":{"code":"OK","name":"Oklahoma"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6680"}],"due_at":"2025-06-04T15:00:00Z","due_date":"2025-06-04","closes_at":"2025-06-04T15:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8125","office_name":"FA8125 AFSC PZIMA","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-13T11:45:57.852297Z","principal_notice_id":"baf436a0bbc54782ad278478ae94cd8a","description":{"text":"The Air Force intends to solicit the following supply:\n\n76 AMXG is requesting utilization of funds for Request for the purchase of 4 ea.\n\nWater Cooled Xray System to include the following:\n\nInput Line Requirements:\n\n• Automatically adapts to input line voltage100-130Vac, 50/60Hz, 20 Amperes maximum.\n\n• 200-250Vac, 50/60Hz, 10 Amperes maximum\n\n• 20 to 160kV, 0.5mA to 5.0mA (800 watts max.)\n\n• Constant potential, end-grounded anode, liquid cooled version\n\nX-Ray Tube Window:\n\n• Beryllium 0.8mm (directional) 40° directional\n\nRadiation Output:\n\n• 14R/min at 50cm filtered with 0.5 inches (12.7mm)\n\n• Aluminum at 160kV, 5mA\n\nRadiation Leakage:\n\n• Less than 2.0 Roentgens per hour at 1 meter from the X-Raytube target\n\n• Effective Focal Spot: Standard: 0.7mm x 1.0mm (0.03in x 0.04in) EN125430.5mm x 0.5mm (0.02in x 0.02in) nominal IEC60336\n\nAmbient Temp:\n\n• 100% duty cycle @ 120°F (49°C)\n\n• Duty Cycle: 100%\n\nStorage Temp:\n\n• -30°F to 160°F (-35°C to 71°C)\n\nAnode Cooling:\n\n• Liquid coolant solution closed loop between X-Ray tube anode and cooling unit.\n\n• Liquid Cooling Unit Weight: 54lbs. (15.4kg) approx.\n\n• Tube Head Dimensions: No greater than 7.25\" Diameter, 30\" Length\n\n• Liquid Cooled: 29lbs. (13.15kg)\n\nX-Ray Control Unit:\n\n• X-Ray Control Unit Weight: 26lbs. (11.8kg) approx\n\nSafety Devices:\n\n• Tubehead Pressure Relief Valve\n\n• Tubehead Thermal Cut-Out\n\n• Tubehead Pressure Gauge\n\n• Tubehead Low Pressure Cut-Out @ 25psi (1.72 Bar)\n\n• Coolant Flow Sensor (liquid cooled only)\n\n• Control Unit Safety Keyswitch\n\n• Microcomputer-based Self Diagnostics\n\n• Continuous Exposure Parameter Display\n\nStandard Accessories:\n\n• Operation manual\n\n• Tubehead carrying case\n\n• Tubehead Cable- 100’ with strain relief\n\n• Extra key (1) for Control Unit Safety Lock\n\n• Power cable - 25’ with strain relief\n\n• Coolant hose - twin, 50’ with self-sealing terminations\n\n• (liquid cooled only)\n\n• Cooler power cable\n\n• GUI Control Software for the GUI is specifically designed for controlling series systems. As an alternative to the front panel control, the GUI will allow the user to control all necessary functions of the system from a user-friendly windows-based menu. Additionally, the GUI can be used as a diagnostic tool when the system is controlled via the front panel.\n\nA Firm Fixed Price type contract is contemplated.\n\nEstimated Period of Performance: 360 days ARO\n\nThis is a small business set-aside\n\nSystem for Award Management (SAM) is required to receive any award. Contractors can register electronically at https://www.sam.gov/portal/public/SAM/. The NAICS code for this requirement is 334519 with a size standard of 600 EMP.\n\nInterested persons may identify their interest and capability to respond to the requirement by submitting a proposal. Electronic procedures will be used for this solicitation through Beta.sam.gov at https://sam.gov/content/home. No telephone requests. See Note 22. Authority is 10 USC 2304 (c)(1).\n\nFor further information contact:\n\nSondra Groth\n\nContracting Specialist\n\nSondra.groth@us.af.mil","html":"<p>The Air Force intends to solicit the following supply:</p>\n\n<p></p>\n\n<p>76 AMXG is requesting utilization of funds for Request for the purchase of 4 ea.</p>\n\n<p>Water Cooled Xray System to include the following:</p>\n\n<p>Input Line Requirements:</p>\n\n<ul>\n\t<li>Automatically adapts to input line voltage100-130Vac, 50/60Hz, 20 Amperes maximum.</li>\n\t<li>200-250Vac, 50/60Hz, 10 Amperes maximum</li>\n\t<li>20 to 160kV, 0.5mA to 5.0mA (800 watts max.)</li>\n\t<li>Constant potential, end-grounded anode, liquid cooled version</li>\n</ul>\n\n<p>X-Ray Tube Window:</p>\n\n<ul>\n\t<li>Beryllium 0.8mm (directional) 40&deg; directional</li>\n</ul>\n\n<p>Radiation Output:</p>\n\n<ul>\n\t<li>14R/min at 50cm filtered with 0.5 inches (12.7mm)</li>\n\t<li>Aluminum at 160kV, 5mA</li>\n</ul>\n\n<p>Radiation Leakage:</p>\n\n<ul>\n\t<li>Less than 2.0 Roentgens per hour at 1 meter from the X-Raytube target</li>\n</ul>\n\n<ul>\n\t<li>Effective Focal Spot: Standard: 0.7mm x 1.0mm (0.03in x 0.04in) EN125430.5mm x 0.5mm (0.02in x 0.02in) nominal IEC60336</li>\n</ul>\n\n<p>Ambient Temp:</p>\n\n<ul>\n\t<li>100% duty cycle @ 120&deg;F (49&deg;C)</li>\n</ul>\n\n<ul>\n\t<li>Duty Cycle: 100%</li>\n</ul>\n\n<p>Storage Temp:</p>\n\n<ul>\n\t<li>-30&deg;F to 160&deg;F (-35&deg;C to 71&deg;C)</li>\n</ul>\n\n<p>Anode Cooling:</p>\n\n<ul>\n\t<li>Liquid coolant solution closed loop between X-Ray tube anode and cooling unit.</li>\n\t<li>Liquid Cooling Unit Weight: 54lbs. (15.4kg) approx.</li>\n\t<li>Tube Head Dimensions: No greater than 7.25&quot; Diameter, 30&quot; Length</li>\n\t<li>Liquid Cooled: 29lbs. (13.15kg)</li>\n</ul>\n\n<p>X-Ray Control Unit:</p>\n\n<ul>\n\t<li>X-Ray Control Unit Weight: 26lbs. (11.8kg) approx</li>\n</ul>\n\n<p>Safety Devices:</p>\n\n<ul>\n\t<li>Tubehead Pressure Relief Valve</li>\n\t<li>Tubehead Thermal Cut-Out</li>\n\t<li>Tubehead Pressure Gauge</li>\n\t<li>Tubehead Low Pressure Cut-Out @ 25psi (1.72 Bar)</li>\n\t<li>Coolant Flow Sensor (liquid cooled only)</li>\n\t<li>Control Unit Safety Keyswitch</li>\n\t<li>Microcomputer-based Self Diagnostics</li>\n\t<li>Continuous Exposure Parameter Display</li>\n</ul>\n\n<p>Standard Accessories:</p>\n\n<ul>\n\t<li>Operation manual</li>\n\t<li>Tubehead carrying case</li>\n\t<li>Tubehead Cable- 100&rsquo; with strain relief</li>\n\t<li>Extra key (1) for Control Unit Safety Lock</li>\n\t<li>Power cable - 25&rsquo; with strain relief</li>\n\t<li>Coolant hose - twin, 50&rsquo; with self-sealing terminations</li>\n\t<li>(liquid cooled only)</li>\n\t<li>Cooler power cable</li>\n\t<li>GUI Control Software for the GUI is specifically designed for controlling series systems. As an alternative to the front panel control, the GUI will allow the user to control all necessary functions of the system from a user-friendly windows-based menu. Additionally, the GUI can be used as a diagnostic tool when the system is controlled via the front panel.</li>\n</ul>\n\n<p></p>\n\n<p>A Firm Fixed Price type contract is contemplated.</p>\n\n<p></p>\n\n<p>Estimated Period of Performance: &nbsp;360 days ARO</p>\n\n<p></p>\n\n<p>This is a small business set-aside</p>\n\n<p></p>\n\n<p>System for Award Management (SAM) is required to receive any award. Contractors can register electronically at https://www.sam.gov/portal/public/SAM/. The NAICS code for this requirement is 334519 with a size standard of 600 EMP.</p>\n\n<p></p>\n\n<p>Interested persons may identify their interest and capability to respond to the requirement by submitting a proposal. Electronic procedures will be used for this solicitation through Beta.sam.gov at https://sam.gov/content/home.&nbsp; No telephone requests. See Note 22. Authority is 10 USC 2304 (c)(1).</p>\n\n<p></p>\n\n<p>For further information contact:</p>\n\n<p>Sondra Groth</p>\n\n<p>Contracting Specialist</p>\n\n<p>Sondra.groth@us.af.mil</p>","origin":"detail"},"contacts":[{"name":"Sondra Groth","role":"primary","email":"Sondra.Groth@us.af.mil"},{"name":"Sheridan Robison","role":"secondary","email":"sheridan.robison@us.af.mil"}],"place_of_performance":{"zip":"73145","city":{"code":"0","name":"Tinker AFB"},"state":{"code":"OK","name":"Oklahoma"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"73145-3303","city":"TINKER AFB","state":"OK","country":"USA"},"naics_codes":["334519"],"award":null,"attachments":[],"awards":[],"related":[{"key":"FA812527Q0001","latest_notice_id":"f0d698a954a34e24b7a8b14112aba02d","title":"Electrostatic Paint Guns and Carts IDIQ","solicitation_number":"FA8125-27-Q-0001","notice_type":"o","first_type":"p","first_posted":"2026-10-02","last_posted":"2026-11-20","notices":2,"due_at":"2026-12-04T16:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8125","office_name":"FA8125 AFSC PZIMA","naics":"333912","psc":"4940","set_aside":"SBA","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"A27031","latest_notice_id":"74c258db6d4c42ca9e70300eafb53283","title":"A27-031 Bay Door Trailer","solicitation_number":"A27-031","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-12-04T18:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8125","office_name":"FA8125 AFSC PZIMA","naics":"336212","psc":null,"set_aside":null,"state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"FA812527Q0015","latest_notice_id":"6995db52618a4c48bca0c5d7bf1ee025","title":"Fall Protection Annual Inspection","solicitation_number":"FA812527Q0015","notice_type":"o","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-04T18:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8125","office_name":"FA8125 AFSC PZIMA","naics":"541990","psc":"J049","set_aside":"SBA","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FA812527Q0009","latest_notice_id":"91a483e2032b48d79d583b8553908553","title":"Med. Press. Pump Module Motor Rebuild","solicitation_number":"FA812527Q0009","notice_type":"o","first_type":"p","first_posted":"2026-11-02","last_posted":"2026-11-20","notices":3,"due_at":"2026-12-10T18:00:00Z","due_date":"2026-12-10","closes_at":"2026-12-10T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8125","office_name":"FA8125 AFSC PZIMA","naics":"811310","psc":"J059","set_aside":"SBA","state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"FA812527Q0013","latest_notice_id":"785df9ba74cf48f6814c0189c2d275bb","title":"Serv C26-127 Repair Test Stands","solicitation_number":"FA812527Q0013","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-11T20:00:00Z","due_date":"2026-12-11","closes_at":"2026-12-11T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8125","office_name":"FA8125 AFSC PZIMA","naics":"811210","psc":"J066","set_aside":null,"state":"OK","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open":[{"key":"1178021","latest_notice_id":"c4173d50f35d4be780dc718d2fdf88f1","title":"HPLC Core System","solicitation_number":"1178021","notice_type":"p","first_type":"p","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12G2","sub_name":"FOOD SAFETY AND INSPECTION SERVICE","office_key":"o-123A94","office_name":"USDA, FSIS, OAS PCMB","naics":"334519","psc":"H252","set_aside":null,"state":"FL","county":"12086","county_name":"Miami-Dade County","city":"1214250","city_name":"Coral Gables","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"SPE4A527T3404","latest_notice_id":"a34ef49f30ec469a97cb56c10001377c","title":"66--ADAPTER,SPEEDOMETER","solicitation_number":"SPE4A527T3404","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A5","office_name":"DLA AVIATION","naics":"334519","psc":"66","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TER: LINE 0001 QTY 469 UI EA DELIVER TO: W1A8 DLA DIST SAN JOAQUIN BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"SPE4A527T3405","latest_notice_id":"4615c11cc94e44fdb354f5a8b1e26ca7","title":"66--ADAPTER,SPEEDOMETER","solicitation_number":"SPE4A527T3405","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A5","office_name":"DLA AVIATION","naics":"334519","psc":"66","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"TER: LINE 0001 QTY 725 UI EA DELIVER TO: W1A8 DLA DIST SAN JOAQUIN BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":49,"indexable":false}