Solicitation, first published as presolicitation
GSA Seeks to Lease the Following Space: 8NC2291
8NC2291
Public Buildings Service, PBS R00 Center for Broker Services. Lessors of Nonresidential Buildings (except Miniwarehouses).
Response deadline
November 14, 2024 at 4:00 PM EST
Closed 742 days ago. Posted October 24, 2024, first published March 7, 2024. Scheduled to archive November 29, 2024.
Get the next one like this from Public Buildings Service by email, the day it is posted.Find my opportunities
This one closed in 2024
68 like it are open now in lessors of nonresidential buildings (except miniwarehouses)
- Succeeding Lease for Jacksonville CBOC
Department of Veterans Affairs, 246-Network Contracting Office 6
Presolicitation8(a) sole sourceNAICS 531120Jacksonville, NC36C24626Q0198Due in 7 daysDec 3 - Sources Sought Fayetteville NC Vet Center New/Replacing Lease
Department of Veterans Affairs, Office of Construction & Facilities MGMT
Sources soughtSDVOSBNAICS 531120Fayetteville, NC36C10F27Q0005Closes in 8 daysDec 4 - U.S. Government Seeks to Lease Office and Related Space in Wilmington, NC
Public Buildings Service, PBS Office of Leasing
SolicitationNAICS 531120Wilmington, NC0NC2145-1Closes in 25 daysDec 21
All 68 open in lessors of nonresidential buildings (except miniwarehouses)
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 531120 (lessors of nonresidential buildings (except miniwarehouses)), means no more than $34 million in average annual receipts, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 21 days from the day the solicitation was posted, October 24, 2024, to the deadline. The deadline moved once: it was first March 29, 2024 and ended as November 14, 2024.
- Before the solicitation
- The agency published a presolicitation on March 7, 2024, 231 days before the solicitation.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
General Services Administration (GSA) seeks to lease the following space:
State:
NC City:
Charlotte Delineated Area: From a starting point at the intersection of the Catawba River and Highway 27- East along Highway 27 to Interstate 485; south along Interstate 485 to West Boulevard; east along West Boulevard and Highway 160 to Billy Graham Parkway; southeast along Billy Graham Parkway to Highway 49; south along Highway 49 to Tyvola Road; east along Tyvola Road to South Boulevard; south along South Boulevard to Arrowood Road; west on Arrowood Road to Interstate 77; south along Interstate 77 to the North Carolina/South Carolina Border; west along the state border to Highway 160; north along Highway 160 to Highway 49; south on Highway 49 to the Catawba River; north along the Catawba River to Highway 29 (starting point). Minimum Sq. Ft.
(ABOA): 5,315 Maximum Sq. Ft.
(ABOA):
5,847 Space Type:
Office:
1,990 ABOA Lab/Special Use:
725 ABOA Light Industrial/Warehouse:
2,600 ABOA Wareyard:
18,600 Parking Spaces (Total):
23 Parking Spaces (Surface):
12 Parking Spaces (Structured):
5 Parking Spaces (Reserved):
6 Full Term:
20 Years Firm Term:
10 Years Option Term:
N/A Additional Requirements: The building(s), ware yard and parking areas shall be all ground level, contiguous space. The warehouse/ware yard operation can be located to the side or behind the main office/laboratory building, but all the warehouse/ware yard space must be within a single, secured, fenced area. Access to the ware yard will be controlled by a keypad and a 20-foot cantilever type gate. Ware yard fencing must be a minimum of 8 feet high. Chain link fencing is not acceptable.
Outdoor lighting must be sufficient for safety, and to ensure preventive lighting for GOV vehicles parked overnight in the parking lot. Small Conference room required. The building site must accommodate good, safe, vehicular access and circulation throughout for large vehicles and vehicles pulling trailers that can reach 45’ in total length with central pivot points like standard semi-trailers or light truck/boat trailer combinations. A drive-through ware yard design is preferred to accommodate these vehicles.
Extreme vehicle turns for vehicles to enter the warehouse must also be avoided, as boats up to 26’ long, on trailers, will frequently be parked inside. The site should be level with the fenced ware yard located to the rear or side of the facility for professional aesthetic purposes. Ware yard space must be located on site. Depending on ware yard layout, additional circulation space may be required in ware yard. The ware yard space must contain a minimum of 18,000 square feet. Ware yard fencing must be a minimum of 8 feet high.
Parking: The fenced, gated and secured wareyard must accommodate 9 standard (10’x20’) open parking spaces plus 6 oversized (12’x24’) open parking spaces for government owned vehicles plus 5 covered spaces (12’x24’) for boats on trailers plus 3 standard open spaces for visitors.
Laboratory: A dual bed deionized water system shall be provided, installed, and maintained by USGS and connected to a dedicated faucet (lessor provided), Lessee will be responsible for tank replacement. A minimum of 2 utility sinks with gooseneck faucet and sprayer in the Wet Lab area. All plumbed for hot and cold water, one sink will have a dedicated deionized water faucet in addition.
The Lessor will be responsible for maintaining and plumbing sinks including an emergency eyewash station with direct access from both labs. The Laboratory HVAC and ventilation system can be on the same air-handling systems as the office space in the building if the return HVAC is not in or near the Lab areas.
Laboratory exhaust system: The Lessor will be responsible for providing, installing, maintaining, and plumbing an exhaust ventilation system (extraction arm, fan, vent), “Snorkel” (vented directly to exterior of building). This system must be acid resistant. The Wet Lab and Electronics Lab require 110 V electrical outlet strips along countertops. A floor level utility sink or confined wash-down area plumbed for both hot and cold is required in the light industrial warehouse area.
Warehouse: Field work preparation area, large equipment maintenance area, equipment storage/cages. A minimum of 11 feet of clear ceiling. Floor Drain with sediment trap and sump required at occupancy. A pedestrian door from warehouse to wareyard or parking area will be required at occupancy. Equipment preparation and testing area, employee lockers.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Morgan D. Walkermorgan.walker@gsa.gov4127792244