{"canonical":"https://sealedbidder.com/opportunities/80ssc026k0001","key":"80SSC026K0001","url":"https://sealedbidder.com/opportunities/80ssc026k0001","title":"Modular Helium Compression System – OEM Equipment Manufacturer Inquiry","solicitation_number":"80SSC026K0001","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-01-16T21:00:00Z","first_posted":"2026-01-06","last_posted":"2026-01-06","department":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","subagency":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office":"NASA SHARED SERVICES CENTER","naics":"333912","psc":"4310","set_aside":null,"place_state":"MS","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"28045","place_county_name":"Hancock County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"769f89dc0a3f4ea381f3abb719bc90f9","title":"Modular Helium Compression System – OEM Equipment Manufacturer Inquiry","solicitation_number":"80SSC026K0001","notice_type":"s","base_type":"s","posted":"2026-01-06","posted_at":"2026-01-06T13:57:04.672Z","due_at":"2026-01-16T21:00:00Z","due_date":"2026-01-16","cancelled":false,"archived":true,"archive_date":"2026-01-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/769f89dc0a3f4ea381f3abb719bc90f9/view","enriched":true,"history":[{"index":3,"title":"Modular Helium Compression System – OEM Equipment Manufacturer Inquiry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-06T13:57:04.672Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"769f89dc0a3f4ea381f3abb719bc90f9","solicitation_number":"80SSC026K0001"}]}],"latest_notice_id":"769f89dc0a3f4ea381f3abb719bc90f9","first_type":"s","notices":[{"dates":{"posted":"2026-01-06","posted_at":"2026-01-06T13:57:04.672Z","created_at":"2026-01-06T13:39:23.355Z","modified_at":"2026-01-31T05:04:27.926Z","response_deadline":{"raw":"2026-01-16T15:00:00-06:00","utc":"2026-01-16T21:00:00Z","date":"2026-01-16","time":"15:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/769f89dc0a3f4ea381f3abb719bc90f9/view"},"naics":{"codes":["333912"],"primary":"333912"},"title":"Modular Helium Compression System – OEM Equipment Manufacturer Inquiry","agency":{"office":{"code":"80NSSC","name":"NASA SHARED SERVICES CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"39529","city":"STENNIS SPACE CENTER","state":"MS","country":"USA"},"organization_id":"100164058","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-01-31","archive_type":"auto15"},"history":[{"index":3,"title":"Modular Helium Compression System – OEM Equipment Manufacturer Inquiry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-06T13:57:04.672Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"769f89dc0a3f4ea381f3abb719bc90f9","solicitation_number":"80SSC026K0001"}],"contacts":[{"name":"Will Garrett","role":"primary","email":"will.c.garrett@nasa.gov"},{"name":"James Hibbs","role":"secondary","email":"james.s.hibbs@nasa.gov"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"769f89dc0a3f4ea381f3abb719bc90f9","lineage_id":"769f89dc0a3f4ea381f3abb719bc90f9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-17T02:54:21.134867528Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"607b553db01568fd3182e9475e7a71749a609ad09e85a3b7b76cdd2d53e89e17","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-17T02:54:21.134867528Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p><strong>Request for Information (RFI)</strong></p>\n\n<p><strong>Title:</strong> Modular Helium Compression System &ndash; OEM Equipment Manufacturer Inquiry<br />\n<strong>Location:</strong> Building 3305, High Pressure Gas Facility, Stennis Space Center, MS 39529</p>\n\n<p><strong>1. Purpose</strong></p>\n\n<p>This Request for Information (RFI) is issued to identify qualified original equipment manufacturers (OEMs) capable of supplying two(2) commercial off-the-shelf (COTS), modular, skid-mounted helium compression system for high-pressure helium applications. The Government is seeking equipment manufacturers only&mdash;not general contractors or engineering firms&mdash;who can provide the equipment only or a complete turnkey solution including surrounding infrastructure design, fabrication, delivery, installation, and commissioning of the system.</p>\n\n<p>The compressed helium will be routed directly into existing on-site infrastructure. The system must be compatible with standard industry transfer connections and designed to integrate seamlessly with existing facility utilities and controls.</p>\n\n<p><strong>2. System Requirements</strong></p>\n\n<p><strong>2.1 Performance Capacity</strong></p>\n\n<ul>\n\t<li>Medium: Helium</li>\n\t<li>Inlet Pressure: 50-175 PSIG</li>\n\t<li>Final Discharge Pressure: 6000 PSIG</li>\n\t<li>Max Capacity: 300 SCFM</li>\n\t<li>VFD Driven</li>\n</ul>\n\n<p><strong>2.2 Technology</strong></p>\n\n<ul>\n\t<li>Fully automated operation with remote/local control capabilities</li>\n\t<li>MODBUS TCP/IP communication</li>\n\t<li>Oil removal filtration system with residual oil content &lt; 0.01 mg/m&sup3;</li>\n</ul>\n\n<p><strong>2.3 Design &amp; Footprint</strong></p>\n\n<ul>\n\t<li>Modular, skid-mounted, cabinet-enclosed configuration</li>\n\t<li>Exterior operation</li>\n\t<li>Sea-level installation</li>\n\t<li>Operating within the following temperature ranges:</li>\n</ul>\n\n<p><strong>Season&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Average High&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Average Low&nbsp; &nbsp;</strong></p>\n\n<p><strong>Winter (Dec&ndash;Feb)</strong>&nbsp; &nbsp; &nbsp; 63&ndash;67&deg;F&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;41&ndash;44&deg;F</p>\n\n<p><strong>Spring (Mar&ndash;May)</strong>&nbsp; &nbsp; &nbsp; 73&ndash;81&deg;F&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;50&ndash;70&deg;F</p>\n\n<p><strong>Summer (Jun&ndash;Aug)</strong>&nbsp; &nbsp; 90&ndash;93&deg;F&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 71&ndash;73&deg;F</p>\n\n<p><strong>Fall (Sep&ndash;Nov)</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;72&ndash;88&deg;F&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;47&ndash;69&deg;F</p>\n\n<p></p>\n\n<p><strong>2.4 Turnkey Scope</strong></p>\n\n<p>OEM must provide (by delivery):</p>\n\n<ul>\n\t<li>Fabrication and factory testing</li>\n\t<li>Delivery and installation</li>\n\t<li>Commissioning and activation</li>\n\t<li>Operator training and documentation</li>\n</ul>\n\n<p><strong>2.5 Operational Features</strong></p>\n\n<ul>\n\t<li>Instrumentation for pressure, temperature, and flow monitoring</li>\n\t<li>Emergency stop and alarm systems</li>\n\t<li>Oil/water separators, safety valves, and ASME-certified buffer tanks</li>\n\t<li>Relocation capability</li>\n</ul>\n\n<p><strong>3. Requested Information &ndash; Interested OEMs are requested to submit the following:</strong></p>\n\n<ul>\n\t<li>Company profile, UEI, business size, socio-economic category, and relevant experience with helium compression systems</li>\n\t<li>Technical specifications of the proposed system</li>\n\t<li>Conceptual diagrams</li>\n\t<li>Utility requirements (power, cooling water, etc.)</li>\n\t<li>Estimated lead time for:\n\t<ul>\n\t\t<li>Procurement/fabrication</li>\n\t\t<li>Delivery</li>\n\t\t<li>Installation and commissioning</li>\n\t</ul>\n\t</li>\n\t<li>Maintenance and support offerings</li>\n\t<li>References or case studies of similar systems delivered</li>\n</ul>\n\n<p><strong>4. Manufacturing and U.S. Presence</strong></p>\n\n<p>Please include:</p>\n\n<ul>\n\t<li>Country of manufacture for major system components</li>\n\t<li>U.S.-based presence (e.g., offices, service teams, fabrication facilities)</li>\n\t<li>Availability of U.S.-based technical support and field service personnel</li>\n</ul>\n\n<p><strong>5. Pricing Information</strong></p>\n\n<p><strong>Please provide the following pricing details:</strong></p>\n\n<ul>\n\t<li>Budgetary Rough Order of Magnitude (ROM) pricing</li>\n\t<li>Tariff-impacted pricing: Include any applicable import duties or tariffs</li>\n\t<li>Non-tariff pricing: Provide pricing assuming no tariffs or duties apply</li>\n\t<li>Notes on tariff origin: Identify any components or subsystems sourced from countries subject to U.S. import tariffs</li>\n</ul>\n\n<p><strong>Additional RFI Information</strong></p>\n\n<p>The market research information gathered from this RFI will be used to develop and plan a potential future procurement. Based upon information submitted in response to this RFI, NASA will determine the final content of any future solicitation(s). A determination by the Government not to procure this requirement, based upon responses to this notice, is solely within the discretion of the Government.</p>\n\n<p>This notice should not be construed as a formal Request for Quotation (RFQ) or Proposal (RFP). Responses to this RFI are not offers and cannot be accepted by NASA to form a binding contract. This notice is not to be construed as a commitment by the Government to make a purchase, nor will the Government pay for the information solicited or be held liable for any information obtained.</p>\n\n<p>Submission of any information in response to this notice is completely voluntary. Comments or suggestions relevant to this requirement are welcome and may also be included in the response. Contractors are welcome to submit any additional documentation that may support their ability to comply with the Government&rsquo;s requirement.</p>\n\n<p>No solicitation exists; therefore, do not request a copy of the solicitation.</p>\n\n<p>Here is a <strong>complete list of acronyms</strong> found across both documents:</p>\n\n<p><strong>Acronym&nbsp; &nbsp; &nbsp; &nbsp;Definition</strong></p>\n\n<p>AC&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Alternating Current</p>\n\n<p>ASME&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;American Society of Mechanical Engineers</p>\n\n<p>ASTM&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;American Society for Testing and Materials</p>\n\n<p>CE&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Conformit&eacute; Europ&eacute;enne (European Conformity)</p>\n\n<p>CSA&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Canadian Standards Association</p>\n\n<p>cULus&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;UL Certification for Canada and the U.S.</p>\n\n<p>CFM&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Cubic Feet per Minute</p>\n\n<p>CTick / RCM&nbsp; &nbsp;Regulatory Compliance Mark (Australia/New Zealand)</p>\n\n<p>EX-WORKS&nbsp; &nbsp; Ex Works (Incoterms &ndash; shipping term)</p>\n\n<p>FM&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Factory Mutual</p>\n\n<p>HMI&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Human-Machine Interface</p>\n\n<p>ISO&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; International Organization for Standardization</p>\n\n<p>lbs&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Pounds</p>\n\n<p>mg/m&sup3;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Milligrams per Cubic Meter</p>\n\n<p>NEMA&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; National Electrical Manufacturers Association</p>\n\n<p>NFPA&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;National Fire Protection Association</p>\n\n<p>P&amp;ID&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Piping and Instrumentation Diagram</p>\n\n<p>PLC&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Programmable Logic Controller</p>\n\n<p>PSIG&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Pounds per Square Inch Gauge</p>\n\n<p>rpm&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Revolutions Per Minute</p>\n\n<p>SCFM&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Standard Cubic Feet per Minute</p>\n\n<p>TEFC&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Totally Enclosed Fan-Cooled</p>\n\n<p>TFT&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Thin-Film Transistor (display technology)</p>\n\n<p>UL&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Underwriters Laboratories</p>\n\n<p>VFD&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Variable Frequency Drive</p>\n\n<p>V&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Volts</p>","text":"Request for Information (RFI)\n\nTitle: Modular Helium Compression System – OEM Equipment Manufacturer Inquiry\n\nLocation: Building 3305, High Pressure Gas Facility, Stennis Space Center, MS 39529\n\n1. Purpose\n\nThis Request for Information (RFI) is issued to identify qualified original equipment manufacturers (OEMs) capable of supplying two(2) commercial off-the-shelf (COTS), modular, skid-mounted helium compression system for high-pressure helium applications. The Government is seeking equipment manufacturers only—not general contractors or engineering firms—who can provide the equipment only or a complete turnkey solution including surrounding infrastructure design, fabrication, delivery, installation, and commissioning of the system.\n\nThe compressed helium will be routed directly into existing on-site infrastructure. The system must be compatible with standard industry transfer connections and designed to integrate seamlessly with existing facility utilities and controls.\n\n2. System Requirements\n\n2.1 Performance Capacity\n\n• Medium: Helium\n\n• Inlet Pressure: 50-175 PSIG\n\n• Final Discharge Pressure: 6000 PSIG\n\n• Max Capacity: 300 SCFM\n\n• VFD Driven\n\n2.2 Technology\n\n• Fully automated operation with remote/local control capabilities\n\n• MODBUS TCP/IP communication\n\n• Oil removal filtration system with residual oil content < 0.01 mg/m³\n\n2.3 Design & Footprint\n\n• Modular, skid-mounted, cabinet-enclosed configuration\n\n• Exterior operation\n\n• Sea-level installation\n\n• Operating within the following temperature ranges:\n\nSeason Average High Average Low\n\nWinter (Dec–Feb) 63–67°F 41–44°F\n\nSpring (Mar–May) 73–81°F 50–70°F\n\nSummer (Jun–Aug) 90–93°F 71–73°F\n\nFall (Sep–Nov) 72–88°F 47–69°F\n\n2.4 Turnkey Scope\n\nOEM must provide (by delivery):\n\n• Fabrication and factory testing\n\n• Delivery and installation\n\n• Commissioning and activation\n\n• Operator training and documentation\n\n2.5 Operational Features\n\n• Instrumentation for pressure, temperature, and flow monitoring\n\n• Emergency stop and alarm systems\n\n• Oil/water separators, safety valves, and ASME-certified buffer tanks\n\n• Relocation capability\n\n3. Requested Information – Interested OEMs are requested to submit the following:\n\n• Company profile, UEI, business size, socio-economic category, and relevant experience with helium compression systems\n\n• Technical specifications of the proposed system\n\n• Conceptual diagrams\n\n• Utility requirements (power, cooling water, etc.)\n\n• Estimated lead time for:\n\n• Procurement/fabrication\n\n• Delivery\n\n• Installation and commissioning\n\n• Maintenance and support offerings\n\n• References or case studies of similar systems delivered\n\n4. Manufacturing and U.S. Presence\n\nPlease include:\n\n• Country of manufacture for major system components\n\n• U.S.-based presence (e.g., offices, service teams, fabrication facilities)\n\n• Availability of U.S.-based technical support and field service personnel\n\n5. Pricing Information\n\nPlease provide the following pricing details:\n\n• Budgetary Rough Order of Magnitude (ROM) pricing\n\n• Tariff-impacted pricing: Include any applicable import duties or tariffs\n\n• Non-tariff pricing: Provide pricing assuming no tariffs or duties apply\n\n• Notes on tariff origin: Identify any components or subsystems sourced from countries subject to U.S. import tariffs\n\nAdditional RFI Information\n\nThe market research information gathered from this RFI will be used to develop and plan a potential future procurement. Based upon information submitted in response to this RFI, NASA will determine the final content of any future solicitation(s). A determination by the Government not to procure this requirement, based upon responses to this notice, is solely within the discretion of the Government.\n\nThis notice should not be construed as a formal Request for Quotation (RFQ) or Proposal (RFP). Responses to this RFI are not offers and cannot be accepted by NASA to form a binding contract. This notice is not to be construed as a commitment by the Government to make a purchase, nor will the Government pay for the information solicited or be held liable for any information obtained.\n\nSubmission of any information in response to this notice is completely voluntary. Comments or suggestions relevant to this requirement are welcome and may also be included in the response. Contractors are welcome to submit any additional documentation that may support their ability to comply with the Government’s requirement.\n\nNo solicitation exists; therefore, do not request a copy of the solicitation.\n\nHere is a complete list of acronyms found across both documents:\n\nAcronym Definition\n\nAC Alternating Current\n\nASME American Society of Mechanical Engineers\n\nASTM American Society for Testing and Materials\n\nCE Conformité Européenne (European Conformity)\n\nCSA Canadian Standards Association\n\ncULus UL Certification for Canada and the U.S.\n\nCFM Cubic Feet per Minute\n\nCTick / RCM Regulatory Compliance Mark (Australia/New Zealand)\n\nEX-WORKS Ex Works (Incoterms – shipping term)\n\nFM Factory Mutual\n\nHMI Human-Machine Interface\n\nISO International Organization for Standardization\n\nlbs Pounds\n\nmg/m³ Milligrams per Cubic Meter\n\nNEMA National Electrical Manufacturers Association\n\nNFPA National Fire Protection Association\n\nP&ID Piping and Instrumentation Diagram\n\nPLC Programmable Logic Controller\n\nPSIG Pounds per Square Inch Gauge\n\nrpm Revolutions Per Minute\n\nSCFM Standard Cubic Feet per Minute\n\nTEFC Totally Enclosed Fan-Cooled\n\nTFT Thin-Film Transistor (display technology)\n\nUL Underwriters Laboratories\n\nVFD Variable Frequency Drive\n\nV Volts","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"80SSC026K0001","place_of_performance":{"zip":"39529","city":{"code":"70505","name":"Stennis Space Center"},"state":{"code":"MS","name":"Mississippi"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4310"}],"due_at":"2026-01-16T21:00:00Z","due_date":"2026-01-16","closes_at":"2026-01-16T21:00:00Z","awardable":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","state":"MS","county":"28045","county_name":"Hancock County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-17T03:13:37.661313Z","principal_notice_id":"769f89dc0a3f4ea381f3abb719bc90f9","description":{"text":"Request for Information (RFI)\n\nTitle: Modular Helium Compression System – OEM Equipment Manufacturer Inquiry\n\nLocation: Building 3305, High Pressure Gas Facility, Stennis Space Center, MS 39529\n\n1. Purpose\n\nThis Request for Information (RFI) is issued to identify qualified original equipment manufacturers (OEMs) capable of supplying two(2) commercial off-the-shelf (COTS), modular, skid-mounted helium compression system for high-pressure helium applications. The Government is seeking equipment manufacturers only—not general contractors or engineering firms—who can provide the equipment only or a complete turnkey solution including surrounding infrastructure design, fabrication, delivery, installation, and commissioning of the system.\n\nThe compressed helium will be routed directly into existing on-site infrastructure. The system must be compatible with standard industry transfer connections and designed to integrate seamlessly with existing facility utilities and controls.\n\n2. System Requirements\n\n2.1 Performance Capacity\n\n• Medium: Helium\n\n• Inlet Pressure: 50-175 PSIG\n\n• Final Discharge Pressure: 6000 PSIG\n\n• Max Capacity: 300 SCFM\n\n• VFD Driven\n\n2.2 Technology\n\n• Fully automated operation with remote/local control capabilities\n\n• MODBUS TCP/IP communication\n\n• Oil removal filtration system with residual oil content < 0.01 mg/m³\n\n2.3 Design & Footprint\n\n• Modular, skid-mounted, cabinet-enclosed configuration\n\n• Exterior operation\n\n• Sea-level installation\n\n• Operating within the following temperature ranges:\n\nSeason Average High Average Low\n\nWinter (Dec–Feb) 63–67°F 41–44°F\n\nSpring (Mar–May) 73–81°F 50–70°F\n\nSummer (Jun–Aug) 90–93°F 71–73°F\n\nFall (Sep–Nov) 72–88°F 47–69°F\n\n2.4 Turnkey Scope\n\nOEM must provide (by delivery):\n\n• Fabrication and factory testing\n\n• Delivery and installation\n\n• Commissioning and activation\n\n• Operator training and documentation\n\n2.5 Operational Features\n\n• Instrumentation for pressure, temperature, and flow monitoring\n\n• Emergency stop and alarm systems\n\n• Oil/water separators, safety valves, and ASME-certified buffer tanks\n\n• Relocation capability\n\n3. Requested Information – Interested OEMs are requested to submit the following:\n\n• Company profile, UEI, business size, socio-economic category, and relevant experience with helium compression systems\n\n• Technical specifications of the proposed system\n\n• Conceptual diagrams\n\n• Utility requirements (power, cooling water, etc.)\n\n• Estimated lead time for:\n\n• Procurement/fabrication\n\n• Delivery\n\n• Installation and commissioning\n\n• Maintenance and support offerings\n\n• References or case studies of similar systems delivered\n\n4. Manufacturing and U.S. Presence\n\nPlease include:\n\n• Country of manufacture for major system components\n\n• U.S.-based presence (e.g., offices, service teams, fabrication facilities)\n\n• Availability of U.S.-based technical support and field service personnel\n\n5. Pricing Information\n\nPlease provide the following pricing details:\n\n• Budgetary Rough Order of Magnitude (ROM) pricing\n\n• Tariff-impacted pricing: Include any applicable import duties or tariffs\n\n• Non-tariff pricing: Provide pricing assuming no tariffs or duties apply\n\n• Notes on tariff origin: Identify any components or subsystems sourced from countries subject to U.S. import tariffs\n\nAdditional RFI Information\n\nThe market research information gathered from this RFI will be used to develop and plan a potential future procurement. Based upon information submitted in response to this RFI, NASA will determine the final content of any future solicitation(s). A determination by the Government not to procure this requirement, based upon responses to this notice, is solely within the discretion of the Government.\n\nThis notice should not be construed as a formal Request for Quotation (RFQ) or Proposal (RFP). Responses to this RFI are not offers and cannot be accepted by NASA to form a binding contract. This notice is not to be construed as a commitment by the Government to make a purchase, nor will the Government pay for the information solicited or be held liable for any information obtained.\n\nSubmission of any information in response to this notice is completely voluntary. Comments or suggestions relevant to this requirement are welcome and may also be included in the response. Contractors are welcome to submit any additional documentation that may support their ability to comply with the Government’s requirement.\n\nNo solicitation exists; therefore, do not request a copy of the solicitation.\n\nHere is a complete list of acronyms found across both documents:\n\nAcronym Definition\n\nAC Alternating Current\n\nASME American Society of Mechanical Engineers\n\nASTM American Society for Testing and Materials\n\nCE Conformité Européenne (European Conformity)\n\nCSA Canadian Standards Association\n\ncULus UL Certification for Canada and the U.S.\n\nCFM Cubic Feet per Minute\n\nCTick / RCM Regulatory Compliance Mark (Australia/New Zealand)\n\nEX-WORKS Ex Works (Incoterms – shipping term)\n\nFM Factory Mutual\n\nHMI Human-Machine Interface\n\nISO International Organization for Standardization\n\nlbs Pounds\n\nmg/m³ Milligrams per Cubic Meter\n\nNEMA National Electrical Manufacturers Association\n\nNFPA National Fire Protection Association\n\nP&ID Piping and Instrumentation Diagram\n\nPLC Programmable Logic Controller\n\nPSIG Pounds per Square Inch Gauge\n\nrpm Revolutions Per Minute\n\nSCFM Standard Cubic Feet per Minute\n\nTEFC Totally Enclosed Fan-Cooled\n\nTFT Thin-Film Transistor (display technology)\n\nUL Underwriters Laboratories\n\nVFD Variable Frequency Drive\n\nV Volts","html":"<p><strong>Request for Information (RFI)</strong></p>\n\n<p><strong>Title:</strong> Modular Helium Compression System &ndash; OEM Equipment Manufacturer Inquiry<br />\n<strong>Location:</strong> Building 3305, High Pressure Gas Facility, Stennis Space Center, MS 39529</p>\n\n<p><strong>1. Purpose</strong></p>\n\n<p>This Request for Information (RFI) is issued to identify qualified original equipment manufacturers (OEMs) capable of supplying two(2) commercial off-the-shelf (COTS), modular, skid-mounted helium compression system for high-pressure helium applications. The Government is seeking equipment manufacturers only&mdash;not general contractors or engineering firms&mdash;who can provide the equipment only or a complete turnkey solution including surrounding infrastructure design, fabrication, delivery, installation, and commissioning of the system.</p>\n\n<p>The compressed helium will be routed directly into existing on-site infrastructure. The system must be compatible with standard industry transfer connections and designed to integrate seamlessly with existing facility utilities and controls.</p>\n\n<p><strong>2. System Requirements</strong></p>\n\n<p><strong>2.1 Performance Capacity</strong></p>\n\n<ul>\n\t<li>Medium: Helium</li>\n\t<li>Inlet Pressure: 50-175 PSIG</li>\n\t<li>Final Discharge Pressure: 6000 PSIG</li>\n\t<li>Max Capacity: 300 SCFM</li>\n\t<li>VFD Driven</li>\n</ul>\n\n<p><strong>2.2 Technology</strong></p>\n\n<ul>\n\t<li>Fully automated operation with remote/local control capabilities</li>\n\t<li>MODBUS TCP/IP communication</li>\n\t<li>Oil removal filtration system with residual oil content &lt; 0.01 mg/m&sup3;</li>\n</ul>\n\n<p><strong>2.3 Design &amp; Footprint</strong></p>\n\n<ul>\n\t<li>Modular, skid-mounted, cabinet-enclosed configuration</li>\n\t<li>Exterior operation</li>\n\t<li>Sea-level installation</li>\n\t<li>Operating within the following temperature ranges:</li>\n</ul>\n\n<p><strong>Season&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Average High&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Average Low&nbsp; &nbsp;</strong></p>\n\n<p><strong>Winter (Dec&ndash;Feb)</strong>&nbsp; &nbsp; &nbsp; 63&ndash;67&deg;F&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;41&ndash;44&deg;F</p>\n\n<p><strong>Spring (Mar&ndash;May)</strong>&nbsp; &nbsp; &nbsp; 73&ndash;81&deg;F&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;50&ndash;70&deg;F</p>\n\n<p><strong>Summer (Jun&ndash;Aug)</strong>&nbsp; &nbsp; 90&ndash;93&deg;F&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 71&ndash;73&deg;F</p>\n\n<p><strong>Fall (Sep&ndash;Nov)</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;72&ndash;88&deg;F&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;47&ndash;69&deg;F</p>\n\n<p></p>\n\n<p><strong>2.4 Turnkey Scope</strong></p>\n\n<p>OEM must provide (by delivery):</p>\n\n<ul>\n\t<li>Fabrication and factory testing</li>\n\t<li>Delivery and installation</li>\n\t<li>Commissioning and activation</li>\n\t<li>Operator training and documentation</li>\n</ul>\n\n<p><strong>2.5 Operational Features</strong></p>\n\n<ul>\n\t<li>Instrumentation for pressure, temperature, and flow monitoring</li>\n\t<li>Emergency stop and alarm systems</li>\n\t<li>Oil/water separators, safety valves, and ASME-certified buffer tanks</li>\n\t<li>Relocation capability</li>\n</ul>\n\n<p><strong>3. Requested Information &ndash; Interested OEMs are requested to submit the following:</strong></p>\n\n<ul>\n\t<li>Company profile, UEI, business size, socio-economic category, and relevant experience with helium compression systems</li>\n\t<li>Technical specifications of the proposed system</li>\n\t<li>Conceptual diagrams</li>\n\t<li>Utility requirements (power, cooling water, etc.)</li>\n\t<li>Estimated lead time for:\n\t<ul>\n\t\t<li>Procurement/fabrication</li>\n\t\t<li>Delivery</li>\n\t\t<li>Installation and commissioning</li>\n\t</ul>\n\t</li>\n\t<li>Maintenance and support offerings</li>\n\t<li>References or case studies of similar systems delivered</li>\n</ul>\n\n<p><strong>4. Manufacturing and U.S. Presence</strong></p>\n\n<p>Please include:</p>\n\n<ul>\n\t<li>Country of manufacture for major system components</li>\n\t<li>U.S.-based presence (e.g., offices, service teams, fabrication facilities)</li>\n\t<li>Availability of U.S.-based technical support and field service personnel</li>\n</ul>\n\n<p><strong>5. Pricing Information</strong></p>\n\n<p><strong>Please provide the following pricing details:</strong></p>\n\n<ul>\n\t<li>Budgetary Rough Order of Magnitude (ROM) pricing</li>\n\t<li>Tariff-impacted pricing: Include any applicable import duties or tariffs</li>\n\t<li>Non-tariff pricing: Provide pricing assuming no tariffs or duties apply</li>\n\t<li>Notes on tariff origin: Identify any components or subsystems sourced from countries subject to U.S. import tariffs</li>\n</ul>\n\n<p><strong>Additional RFI Information</strong></p>\n\n<p>The market research information gathered from this RFI will be used to develop and plan a potential future procurement. Based upon information submitted in response to this RFI, NASA will determine the final content of any future solicitation(s). A determination by the Government not to procure this requirement, based upon responses to this notice, is solely within the discretion of the Government.</p>\n\n<p>This notice should not be construed as a formal Request for Quotation (RFQ) or Proposal (RFP). Responses to this RFI are not offers and cannot be accepted by NASA to form a binding contract. This notice is not to be construed as a commitment by the Government to make a purchase, nor will the Government pay for the information solicited or be held liable for any information obtained.</p>\n\n<p>Submission of any information in response to this notice is completely voluntary. Comments or suggestions relevant to this requirement are welcome and may also be included in the response. Contractors are welcome to submit any additional documentation that may support their ability to comply with the Government&rsquo;s requirement.</p>\n\n<p>No solicitation exists; therefore, do not request a copy of the solicitation.</p>\n\n<p>Here is a <strong>complete list of acronyms</strong> found across both documents:</p>\n\n<p><strong>Acronym&nbsp; &nbsp; &nbsp; &nbsp;Definition</strong></p>\n\n<p>AC&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Alternating Current</p>\n\n<p>ASME&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;American Society of Mechanical Engineers</p>\n\n<p>ASTM&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;American Society for Testing and Materials</p>\n\n<p>CE&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Conformit&eacute; Europ&eacute;enne (European Conformity)</p>\n\n<p>CSA&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Canadian Standards Association</p>\n\n<p>cULus&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;UL Certification for Canada and the U.S.</p>\n\n<p>CFM&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Cubic Feet per Minute</p>\n\n<p>CTick / RCM&nbsp; &nbsp;Regulatory Compliance Mark (Australia/New Zealand)</p>\n\n<p>EX-WORKS&nbsp; &nbsp; Ex Works (Incoterms &ndash; shipping term)</p>\n\n<p>FM&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Factory Mutual</p>\n\n<p>HMI&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Human-Machine Interface</p>\n\n<p>ISO&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; International Organization for Standardization</p>\n\n<p>lbs&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Pounds</p>\n\n<p>mg/m&sup3;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Milligrams per Cubic Meter</p>\n\n<p>NEMA&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; National Electrical Manufacturers Association</p>\n\n<p>NFPA&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;National Fire Protection Association</p>\n\n<p>P&amp;ID&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Piping and Instrumentation Diagram</p>\n\n<p>PLC&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Programmable Logic Controller</p>\n\n<p>PSIG&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Pounds per Square Inch Gauge</p>\n\n<p>rpm&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Revolutions Per Minute</p>\n\n<p>SCFM&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Standard Cubic Feet per Minute</p>\n\n<p>TEFC&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Totally Enclosed Fan-Cooled</p>\n\n<p>TFT&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Thin-Film Transistor (display technology)</p>\n\n<p>UL&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Underwriters Laboratories</p>\n\n<p>VFD&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Variable Frequency Drive</p>\n\n<p>V&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Volts</p>","origin":"detail"},"contacts":[{"name":"Will Garrett","role":"primary","email":"will.c.garrett@nasa.gov"},{"name":"James Hibbs","role":"secondary","email":"james.s.hibbs@nasa.gov"}],"place_of_performance":{"zip":"39529","city":{"code":"70505","name":"Stennis Space Center"},"state":{"code":"MS","name":"Mississippi"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"39529","city":"STENNIS SPACE CENTER","state":"MS","country":"USA"},"naics_codes":["333912"],"award":null,"attachments":[],"awards":[],"related":[{"key":"80NSSC27948984Q","latest_notice_id":"8633902fb0824dcdb772b67cf406e07e","title":"Cryostar, 3 High Pressure Pumps for Liquid Oxygen System, RECIPROCATING PUMP A-MRP 40/55 OL1 T and 1 Triple Auto Control Panel for Liquid Oxygen Pumps","solicitation_number":"80NSSC27948984Q","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-25T13:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"334516","psc":"6695","set_aside":"SBA","state":"NM","county":"35013","county_name":"Doña Ana County","city":"3539380","city_name":"Las Cruces","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"80NSSC27947369Q","latest_notice_id":"602514aa427e466f9c278285ecd835a0","title":"UPS for Microfabrication Laboratory","solicitation_number":"80NSSC27947369Q","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-23","notices":2,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"541519","psc":"6640","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"80NSSC27949205Q","latest_notice_id":"23182628fc84473aa336c4cd21585a65","title":"Universal Robotics e-Series Arm","solicitation_number":"80NSSC27949205Q","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"541330","psc":"7E21","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"80NSSC27949318Q","latest_notice_id":"0d066648ad374f69b192a8c73bf3f559","title":"Haskel Booster & Components","solicitation_number":"80NSSC27949318Q","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"561210","psc":"4940","set_aside":"SBA","state":"MS","county":"28045","county_name":"Hancock County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"80NSSC27949511Q","latest_notice_id":"32155ad9ab43432e987d8704cc829839","title":"Propellant Skid AN Fitting","solicitation_number":"80NSSC27949511Q","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"332919","psc":"4920","set_aside":"SBA","state":"NM","county":"35013","county_name":"Doña Ana County","city":"3539380","city_name":"Las Cruces","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"FA9101SERVICEAIRSYSTEMREVITALIZATION","latest_notice_id":"d1c20208659a41958893a9629cbe0aca","title":"Service Air System Revitalization","solicitation_number":"FA9101_Service_Air_System_Revitalization","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T20:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA9101","office_name":"FA9101 AEDC PKP PROCRMNT BR","naics":"333912","psc":"4310","set_aside":null,"state":"TN","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"SPE7M127R0008","latest_notice_id":"692ca600f1fa44269084e0ba9b76541a","title":"PARTS KIT,COMPRESSOR 4310-01-480-5743","solicitation_number":"SPE7M127R0008","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE7M1","office_name":"DLA WEAPONS SUPPORT","naics":"333912","psc":"4310","set_aside":null,"state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"W31P4Q27RA010","latest_notice_id":"cdef7068a7374706adeb240e890111c7","title":"COMPRESSOR UNIT","solicitation_number":"W31P4Q27RA010","notice_type":"o","first_type":"o","first_posted":"2026-10-15","last_posted":"2026-10-15","notices":2,"due_at":"2026-11-26T22:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W31P4Q","office_name":"W6QK ACC-RSA","naics":"333912","psc":"4310","set_aside":null,"state":"TX","county":"48141","county_name":"El Paso County","city":"4826664","city_name":"Fort Bliss","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-16T03:38:05.572608Z"}],"similar_open_total":28,"indexable":false}