{"canonical":"https://sealedbidder.com/opportunities/75n98026r00099","key":"75N98026R00099","url":"https://sealedbidder.com/opportunities/75n98026r00099","title":"Equipment: Cytek Aurora EVO 5 Laser","solicitation_number":"75N98026R00099","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-23T21:00:00Z","first_posted":"2026-06-16","last_posted":"2026-06-16","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"NATIONAL INSTITUTES OF HEALTH","office":"NATIONAL INSTITUTES OF HEALTH NICHD","naics":"334516","psc":"6640","set_aside":"SBA","place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"ede3bb0e1c344284b87258b61fce696c","title":"Equipment: Cytek Aurora EVO 5 Laser","solicitation_number":"75N98026R00099","notice_type":"r","base_type":"r","posted":"2026-06-16","posted_at":"2026-06-16T20:51:33.778Z","due_at":"2026-06-23T21:00:00Z","due_date":"2026-06-23","cancelled":false,"archived":true,"archive_date":"2026-06-24","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ede3bb0e1c344284b87258b61fce696c/view","enriched":true,"history":[{"index":3,"title":"Equipment: Cytek Aurora EVO 5 Laser","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-16T20:51:33.778Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ede3bb0e1c344284b87258b61fce696c","solicitation_number":"75N98026R00099"}]}],"latest_notice_id":"ede3bb0e1c344284b87258b61fce696c","first_type":"r","notices":[{"dates":{"posted":"2026-06-16","posted_at":"2026-06-16T20:51:33.778Z","created_at":"2026-06-16T20:44:34.731Z","modified_at":"2026-06-25T03:55:44.202Z","response_deadline":{"raw":"2026-06-23T17:00:00-04:00","utc":"2026-06-23T21:00:00Z","date":"2026-06-23","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ede3bb0e1c344284b87258b61fce696c/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Equipment: Cytek Aurora EVO 5 Laser","agency":{"office":{"code":"75N940","name":"NATIONAL INSTITUTES OF HEALTH NICHD"},"subtier":{"code":"7529","name":"NATIONAL INSTITUTES OF HEALTH"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20817","city":"BETHESDA","state":"MD","country":"USA"},"organization_id":"100189043","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-24","archive_type":"auto_custom"},"history":[{"index":3,"title":"Equipment: Cytek Aurora EVO 5 Laser","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-16T20:51:33.778Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ede3bb0e1c344284b87258b61fce696c","solicitation_number":"75N98026R00099"}],"contacts":[{"name":"ROBINSON, TINA","role":"primary","email":"robinsti@mail.nih.gov"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"ede3bb0e1c344284b87258b61fce696c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"ede3bb0e1c344284b87258b61fce696c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T03:40:46.837452455Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"358eb19543975d82907e5099a8a21f9c429ad9a54b55dc1390b8ce481ca96fc4","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-02T03:40:46.837452455Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The National Institutes of Health (NIH), Office of the Director (OD) is conducting a market survey<br />\nto determine the availability and technical capability of qualified small businesses, including 8(a)<br />\nsmall businesses, small, disadvantaged businesses, woman-owned small businesses, servicedisabled<br />\nveteran-owned small businesses or HUBZone small businesses capable of providing a<br />\nnew Brand name or equal to Cytek Biosciences: Cytek Aurora EVO 5 Laser UV/YG/V/B/R and<br />\nCytek Aurora-CS 5 Laser UV/YG/V/B/R.<br />\nProduct Specifications/Features/Salient Characteristics Required Minimum Specifications:<br />\nThe request is for a 5-laser spectral flow cytometry system consisting of both a spectral analyzer<br />\nand a 6-way spectral cell sorter with small particle detection, designed for high-plex and small<br />\nparticle studies.<br />\nCore System Requirements<br />\n&middot; Both analyzer and sorter must:<br />\n&middot; Use software platform to enable seamless experiment/data transfer and analysis.<br />\n&middot; Support spectral continuity between analyzer and sorter.<br />\n&middot; Operate with a 5-laser configuration:<br />\no UV (355 nm)<br />\no Violet (405 nm)<br />\no Blue (488 nm)<br />\no Yellow-green (561 nm)<br />\no Red (640 nm)<br />\n&middot; Detect fluorescence up to 825 nm or higher wavelength.<br />\n&middot; Perform live spectral unmixing.<br />\n&middot; Calculate autofluorescence as a separate parameter.<br />\n&middot; Generate data compliant with Flow Cytometry Standard (FCS) 3.1 or higher.<br />\n&middot; Be compatible with major analysis platforms (OMIQ, FlowJo, Cytobank, FCS Express,<br />\netc.).<br />\n&middot; Include an automated QC module.<br />\n&middot; Include all required attachments for full functionality.<br />\nAnalyzer-Specific Requirements<br />\n&middot; Equipped with an autoloader supporting:<br />\no 96-well standard plates<br />\no 96-well deep-well plates<br />\no 384-well plates<br />\no Individual or rack-based 12 &times; 75 mm tubes<br />\n&middot; Protocols developed on the analyzer must be transferable to the sorter.<br />\nSorter-Specific Requirements<br />\n&middot; 6-way sorting capability.<br />\n&middot; Capable of aseptic sorting into:<br />\no 1.5&ndash;1.8 mL Eppendorf tubes<br />\no 96-well cell culture plates<br />\no 384-well plates<br />\no 96-well PCR plates<br />\n&middot; Support for 70 &mu;m, 100 &mu;m, and 130 &mu;m nozzle sizes.<br />\n&middot; Include a vendor-tested biosafety hood for proper aerosol containment.<br />\n&middot; Must support small particle detection.<br />\nOverall, the system must provide integrated, high-plex spectral particle/cytometric analysis and<br />\nhigh-plex spectral cell/particle sorting with seamless workflow continuity, advanced unmixing<br />\ncapabilities, small particle detection, and compliance with current data standards. Both units must<br />\nmeet NIH workplace instrumentation requirements. Instruments must come with 5-year extended<br />\nwarranty and onsite field service support.<br />\nInterested firms with the capability of providing all the required items shall submit a capability<br />\nstatement to assist the Government in determining in accordance with the Federal Acquisition<br />\nRegulation 19.104-1.<br />\nThe intended procurement will be classified under North American Industrial Classification<br />\n(NAICS) code 334516 with a size standard of 1000e. All respondents are required to identify their<br />\nfirm&rsquo;s size and type of business. Interested firms responding to this market survey must provide<br />\n(a) capability statement demonstrating their experience, skills and capability to fulfill the<br />\nGovernment&rsquo;s requirements for the above. The capability statement shall be in sufficient enough<br />\ndetails so that the Government can determine the experience and capability of your firm to provide<br />\nthe items above. Offers must also be accompanied by descriptive literature, delivery timeframe,<br />\nwarranties and other information that demonstrates that the offer meets all the foregoing<br />\nrequirements. Capability statements must include the name and telephone number, and email<br />\naddress of a point of contact having authority and knowledge to discuss responses with<br />\nGovernment representatives. Capability statements in response to the market survey that do not<br />\nprovide sufficient information for evaluation will be considered non-responsive. A copy of the<br />\ncapability statement must be received via email to robinsti@mail.nih.gov Attn: Tina Robinson<br />\nprior to 5:00 pm eastern daylight time on June 23, 2026. Capability statement must reference<br />\nsolicitation# 75N98026R00099. Submission by email must also reference solicitation<br />\n# 75N98026R00099 on the subject line of the email. Any questions must be sent via email to<br />\nrobinsti@mail.nih.gov and must include solicitation# 75N98026R00099 on the subject line of<br />\nemail. Capability statements, etc will not be returned to firm/sender. This synopsis is for<br />\ninformation and planning purposes and is not to be construed as a commitment by the<br />\nGovernment, nor will the Government pay for information solicited.</p>","text":"The National Institutes of Health (NIH), Office of the Director (OD) is conducting a market survey\n\nto determine the availability and technical capability of qualified small businesses, including 8(a)\n\nsmall businesses, small, disadvantaged businesses, woman-owned small businesses, servicedisabled\n\nveteran-owned small businesses or HUBZone small businesses capable of providing a\n\nnew Brand name or equal to Cytek Biosciences: Cytek Aurora EVO 5 Laser UV/YG/V/B/R and\n\nCytek Aurora-CS 5 Laser UV/YG/V/B/R.\n\nProduct Specifications/Features/Salient Characteristics Required Minimum Specifications:\n\nThe request is for a 5-laser spectral flow cytometry system consisting of both a spectral analyzer\n\nand a 6-way spectral cell sorter with small particle detection, designed for high-plex and small\n\nparticle studies.\n\nCore System Requirements\n\n· Both analyzer and sorter must:\n\n· Use software platform to enable seamless experiment/data transfer and analysis.\n\n· Support spectral continuity between analyzer and sorter.\n\n· Operate with a 5-laser configuration:\n\no UV (355 nm)\n\no Violet (405 nm)\n\no Blue (488 nm)\n\no Yellow-green (561 nm)\n\no Red (640 nm)\n\n· Detect fluorescence up to 825 nm or higher wavelength.\n\n· Perform live spectral unmixing.\n\n· Calculate autofluorescence as a separate parameter.\n\n· Generate data compliant with Flow Cytometry Standard (FCS) 3.1 or higher.\n\n· Be compatible with major analysis platforms (OMIQ, FlowJo, Cytobank, FCS Express,\n\netc.).\n\n· Include an automated QC module.\n\n· Include all required attachments for full functionality.\n\nAnalyzer-Specific Requirements\n\n· Equipped with an autoloader supporting:\n\no 96-well standard plates\n\no 96-well deep-well plates\n\no 384-well plates\n\no Individual or rack-based 12 × 75 mm tubes\n\n· Protocols developed on the analyzer must be transferable to the sorter.\n\nSorter-Specific Requirements\n\n· 6-way sorting capability.\n\n· Capable of aseptic sorting into:\n\no 1.5–1.8 mL Eppendorf tubes\n\no 96-well cell culture plates\n\no 384-well plates\n\no 96-well PCR plates\n\n· Support for 70 μm, 100 μm, and 130 μm nozzle sizes.\n\n· Include a vendor-tested biosafety hood for proper aerosol containment.\n\n· Must support small particle detection.\n\nOverall, the system must provide integrated, high-plex spectral particle/cytometric analysis and\n\nhigh-plex spectral cell/particle sorting with seamless workflow continuity, advanced unmixing\n\ncapabilities, small particle detection, and compliance with current data standards. Both units must\n\nmeet NIH workplace instrumentation requirements. Instruments must come with 5-year extended\n\nwarranty and onsite field service support.\n\nInterested firms with the capability of providing all the required items shall submit a capability\n\nstatement to assist the Government in determining in accordance with the Federal Acquisition\n\nRegulation 19.104-1.\n\nThe intended procurement will be classified under North American Industrial Classification\n\n(NAICS) code 334516 with a size standard of 1000e. All respondents are required to identify their\n\nfirm’s size and type of business. Interested firms responding to this market survey must provide\n\n(a) capability statement demonstrating their experience, skills and capability to fulfill the\n\nGovernment’s requirements for the above. The capability statement shall be in sufficient enough\n\ndetails so that the Government can determine the experience and capability of your firm to provide\n\nthe items above. Offers must also be accompanied by descriptive literature, delivery timeframe,\n\nwarranties and other information that demonstrates that the offer meets all the foregoing\n\nrequirements. Capability statements must include the name and telephone number, and email\n\naddress of a point of contact having authority and knowledge to discuss responses with\n\nGovernment representatives. Capability statements in response to the market survey that do not\n\nprovide sufficient information for evaluation will be considered non-responsive. A copy of the\n\ncapability statement must be received via email to robinsti@mail.nih.gov Attn: Tina Robinson\n\nprior to 5:00 pm eastern daylight time on June 23, 2026. Capability statement must reference\n\nsolicitation# 75N98026R00099. Submission by email must also reference solicitation\n\n# 75N98026R00099 on the subject line of the email. Any questions must be sent via email to\n\nrobinsti@mail.nih.gov and must include solicitation# 75N98026R00099 on the subject line of\n\nemail. Capability statements, etc will not be returned to firm/sender. This synopsis is for\n\ninformation and planning purposes and is not to be construed as a commitment by the\n\nGovernment, nor will the Government pay for information solicited.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"75N98026R00099","place_of_performance":{"zip":"20892","state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"}],"due_at":"2026-06-23T21:00:00Z","due_date":"2026-06-23","closes_at":"2026-06-23T21:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N940","office_name":"NATIONAL INSTITUTES OF HEALTH NICHD","state":"MD","county":"24031","county_name":"Montgomery County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T03:45:26.695804Z","principal_notice_id":"ede3bb0e1c344284b87258b61fce696c","description":{"text":"The National Institutes of Health (NIH), Office of the Director (OD) is conducting a market survey\n\nto determine the availability and technical capability of qualified small businesses, including 8(a)\n\nsmall businesses, small, disadvantaged businesses, woman-owned small businesses, servicedisabled\n\nveteran-owned small businesses or HUBZone small businesses capable of providing a\n\nnew Brand name or equal to Cytek Biosciences: Cytek Aurora EVO 5 Laser UV/YG/V/B/R and\n\nCytek Aurora-CS 5 Laser UV/YG/V/B/R.\n\nProduct Specifications/Features/Salient Characteristics Required Minimum Specifications:\n\nThe request is for a 5-laser spectral flow cytometry system consisting of both a spectral analyzer\n\nand a 6-way spectral cell sorter with small particle detection, designed for high-plex and small\n\nparticle studies.\n\nCore System Requirements\n\n· Both analyzer and sorter must:\n\n· Use software platform to enable seamless experiment/data transfer and analysis.\n\n· Support spectral continuity between analyzer and sorter.\n\n· Operate with a 5-laser configuration:\n\no UV (355 nm)\n\no Violet (405 nm)\n\no Blue (488 nm)\n\no Yellow-green (561 nm)\n\no Red (640 nm)\n\n· Detect fluorescence up to 825 nm or higher wavelength.\n\n· Perform live spectral unmixing.\n\n· Calculate autofluorescence as a separate parameter.\n\n· Generate data compliant with Flow Cytometry Standard (FCS) 3.1 or higher.\n\n· Be compatible with major analysis platforms (OMIQ, FlowJo, Cytobank, FCS Express,\n\netc.).\n\n· Include an automated QC module.\n\n· Include all required attachments for full functionality.\n\nAnalyzer-Specific Requirements\n\n· Equipped with an autoloader supporting:\n\no 96-well standard plates\n\no 96-well deep-well plates\n\no 384-well plates\n\no Individual or rack-based 12 × 75 mm tubes\n\n· Protocols developed on the analyzer must be transferable to the sorter.\n\nSorter-Specific Requirements\n\n· 6-way sorting capability.\n\n· Capable of aseptic sorting into:\n\no 1.5–1.8 mL Eppendorf tubes\n\no 96-well cell culture plates\n\no 384-well plates\n\no 96-well PCR plates\n\n· Support for 70 μm, 100 μm, and 130 μm nozzle sizes.\n\n· Include a vendor-tested biosafety hood for proper aerosol containment.\n\n· Must support small particle detection.\n\nOverall, the system must provide integrated, high-plex spectral particle/cytometric analysis and\n\nhigh-plex spectral cell/particle sorting with seamless workflow continuity, advanced unmixing\n\ncapabilities, small particle detection, and compliance with current data standards. Both units must\n\nmeet NIH workplace instrumentation requirements. Instruments must come with 5-year extended\n\nwarranty and onsite field service support.\n\nInterested firms with the capability of providing all the required items shall submit a capability\n\nstatement to assist the Government in determining in accordance with the Federal Acquisition\n\nRegulation 19.104-1.\n\nThe intended procurement will be classified under North American Industrial Classification\n\n(NAICS) code 334516 with a size standard of 1000e. All respondents are required to identify their\n\nfirm’s size and type of business. Interested firms responding to this market survey must provide\n\n(a) capability statement demonstrating their experience, skills and capability to fulfill the\n\nGovernment’s requirements for the above. The capability statement shall be in sufficient enough\n\ndetails so that the Government can determine the experience and capability of your firm to provide\n\nthe items above. Offers must also be accompanied by descriptive literature, delivery timeframe,\n\nwarranties and other information that demonstrates that the offer meets all the foregoing\n\nrequirements. Capability statements must include the name and telephone number, and email\n\naddress of a point of contact having authority and knowledge to discuss responses with\n\nGovernment representatives. Capability statements in response to the market survey that do not\n\nprovide sufficient information for evaluation will be considered non-responsive. A copy of the\n\ncapability statement must be received via email to robinsti@mail.nih.gov Attn: Tina Robinson\n\nprior to 5:00 pm eastern daylight time on June 23, 2026. Capability statement must reference\n\nsolicitation# 75N98026R00099. Submission by email must also reference solicitation\n\n# 75N98026R00099 on the subject line of the email. Any questions must be sent via email to\n\nrobinsti@mail.nih.gov and must include solicitation# 75N98026R00099 on the subject line of\n\nemail. Capability statements, etc will not be returned to firm/sender. This synopsis is for\n\ninformation and planning purposes and is not to be construed as a commitment by the\n\nGovernment, nor will the Government pay for information solicited.","html":"<p>The National Institutes of Health (NIH), Office of the Director (OD) is conducting a market survey<br />\nto determine the availability and technical capability of qualified small businesses, including 8(a)<br />\nsmall businesses, small, disadvantaged businesses, woman-owned small businesses, servicedisabled<br />\nveteran-owned small businesses or HUBZone small businesses capable of providing a<br />\nnew Brand name or equal to Cytek Biosciences: Cytek Aurora EVO 5 Laser UV/YG/V/B/R and<br />\nCytek Aurora-CS 5 Laser UV/YG/V/B/R.<br />\nProduct Specifications/Features/Salient Characteristics Required Minimum Specifications:<br />\nThe request is for a 5-laser spectral flow cytometry system consisting of both a spectral analyzer<br />\nand a 6-way spectral cell sorter with small particle detection, designed for high-plex and small<br />\nparticle studies.<br />\nCore System Requirements<br />\n&middot; Both analyzer and sorter must:<br />\n&middot; Use software platform to enable seamless experiment/data transfer and analysis.<br />\n&middot; Support spectral continuity between analyzer and sorter.<br />\n&middot; Operate with a 5-laser configuration:<br />\no UV (355 nm)<br />\no Violet (405 nm)<br />\no Blue (488 nm)<br />\no Yellow-green (561 nm)<br />\no Red (640 nm)<br />\n&middot; Detect fluorescence up to 825 nm or higher wavelength.<br />\n&middot; Perform live spectral unmixing.<br />\n&middot; Calculate autofluorescence as a separate parameter.<br />\n&middot; Generate data compliant with Flow Cytometry Standard (FCS) 3.1 or higher.<br />\n&middot; Be compatible with major analysis platforms (OMIQ, FlowJo, Cytobank, FCS Express,<br />\netc.).<br />\n&middot; Include an automated QC module.<br />\n&middot; Include all required attachments for full functionality.<br />\nAnalyzer-Specific Requirements<br />\n&middot; Equipped with an autoloader supporting:<br />\no 96-well standard plates<br />\no 96-well deep-well plates<br />\no 384-well plates<br />\no Individual or rack-based 12 &times; 75 mm tubes<br />\n&middot; Protocols developed on the analyzer must be transferable to the sorter.<br />\nSorter-Specific Requirements<br />\n&middot; 6-way sorting capability.<br />\n&middot; Capable of aseptic sorting into:<br />\no 1.5&ndash;1.8 mL Eppendorf tubes<br />\no 96-well cell culture plates<br />\no 384-well plates<br />\no 96-well PCR plates<br />\n&middot; Support for 70 &mu;m, 100 &mu;m, and 130 &mu;m nozzle sizes.<br />\n&middot; Include a vendor-tested biosafety hood for proper aerosol containment.<br />\n&middot; Must support small particle detection.<br />\nOverall, the system must provide integrated, high-plex spectral particle/cytometric analysis and<br />\nhigh-plex spectral cell/particle sorting with seamless workflow continuity, advanced unmixing<br />\ncapabilities, small particle detection, and compliance with current data standards. Both units must<br />\nmeet NIH workplace instrumentation requirements. Instruments must come with 5-year extended<br />\nwarranty and onsite field service support.<br />\nInterested firms with the capability of providing all the required items shall submit a capability<br />\nstatement to assist the Government in determining in accordance with the Federal Acquisition<br />\nRegulation 19.104-1.<br />\nThe intended procurement will be classified under North American Industrial Classification<br />\n(NAICS) code 334516 with a size standard of 1000e. All respondents are required to identify their<br />\nfirm&rsquo;s size and type of business. Interested firms responding to this market survey must provide<br />\n(a) capability statement demonstrating their experience, skills and capability to fulfill the<br />\nGovernment&rsquo;s requirements for the above. The capability statement shall be in sufficient enough<br />\ndetails so that the Government can determine the experience and capability of your firm to provide<br />\nthe items above. Offers must also be accompanied by descriptive literature, delivery timeframe,<br />\nwarranties and other information that demonstrates that the offer meets all the foregoing<br />\nrequirements. Capability statements must include the name and telephone number, and email<br />\naddress of a point of contact having authority and knowledge to discuss responses with<br />\nGovernment representatives. Capability statements in response to the market survey that do not<br />\nprovide sufficient information for evaluation will be considered non-responsive. A copy of the<br />\ncapability statement must be received via email to robinsti@mail.nih.gov Attn: Tina Robinson<br />\nprior to 5:00 pm eastern daylight time on June 23, 2026. Capability statement must reference<br />\nsolicitation# 75N98026R00099. Submission by email must also reference solicitation<br />\n# 75N98026R00099 on the subject line of the email. Any questions must be sent via email to<br />\nrobinsti@mail.nih.gov and must include solicitation# 75N98026R00099 on the subject line of<br />\nemail. Capability statements, etc will not be returned to firm/sender. This synopsis is for<br />\ninformation and planning purposes and is not to be construed as a commitment by the<br />\nGovernment, nor will the Government pay for information solicited.</p>","origin":"detail"},"contacts":[{"name":"ROBINSON, TINA","role":"primary","email":"robinsti@mail.nih.gov"}],"place_of_performance":{"zip":"20892","state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20817","city":"BETHESDA","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[],"awards":[],"related":[{"key":"75N94026R00008","latest_notice_id":"7a9a273a5e614865aa0867cfef3c58a1","title":"Best Pharmaceuticals for Children Act Data Coordination Center","solicitation_number":"75N94026R00008","notice_type":"o","first_type":"r","first_posted":"2026-03-16","last_posted":"2026-11-03","notices":5,"due_at":"2026-12-18T21:00:00Z","due_date":"2026-12-18","closes_at":"2026-12-18T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N940","office_name":"NATIONAL INSTITUTES OF HEALTH NICHD","naics":"541715","psc":"AN12","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Research and development (PSC AN12)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-04T05:14:00.353426Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}