{"canonical":"https://sealedbidder.com/opportunities/75n98026q01157","key":"75N98026Q01157","url":"https://sealedbidder.com/opportunities/75n98026q01157","title":"Alamar ARGO HT System","solicitation_number":"75N98026Q01157","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-09-17T13:00:00Z","first_posted":"2026-09-08","last_posted":"2026-09-08","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"NATIONAL INSTITUTES OF HEALTH","office":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":"SBA","place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":"2407125","place_city_name":"Bethesda","winner":null,"award_amount":null,"publications":[{"notice_id":"b8edf08457d54b63b193016f93f958f5","title":"Alamar ARGO HT System","solicitation_number":"75N98026Q01157","notice_type":"k","base_type":"k","posted":"2026-09-08","posted_at":"2026-09-08T13:26:21.688Z","due_at":"2026-09-17T13:00:00Z","due_date":"2026-09-17","cancelled":false,"archived":true,"archive_date":"2026-10-02","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b8edf08457d54b63b193016f93f958f5/view","enriched":true,"history":[{"index":1,"title":"Alamar ARGO HT System","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-08T13:26:21.688Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"b8edf08457d54b63b193016f93f958f5","solicitation_number":"75N98026Q01157"}]}],"latest_notice_id":"b8edf08457d54b63b193016f93f958f5","first_type":"k","notices":[{"dates":{"posted":"2026-09-08","posted_at":"2026-09-08T13:26:21.688Z","created_at":"2026-09-08T13:21:55.757Z","modified_at":"2026-09-08T13:26:21.692Z","response_deadline":{"raw":"2026-09-17T09:00:00-04:00","utc":"2026-09-17T13:00:00Z","date":"2026-09-17","time":"09:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b8edf08457d54b63b193016f93f958f5/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Alamar ARGO HT System","agency":{"office":{"code":"75N980","name":"NATIONAL INSTITUTES OF HEALTH OLAO"},"subtier":{"code":"7529","name":"NATIONAL INSTITUTES OF HEALTH"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-02","archive_type":"auto15"},"history":[{"index":1,"title":"Alamar ARGO HT System","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-08T13:26:21.688Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"b8edf08457d54b63b193016f93f958f5","solicitation_number":"75N98026Q01157"}],"contacts":[{"name":"Brian Lind","role":"primary","email":"brian.lind@nih.gov","phone":"0000000000"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"b8edf08457d54b63b193016f93f958f5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"b8edf08457d54b63b193016f93f958f5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-16T14:36:56.526159543Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"df973cf0b5d2c0199677a72164dfa332-27\"","fetched_at":"2026-10-02T04:14:23.923188772Z","row_sha256":"eba1fb0b3774d174c1d72db8ae71a41b4d10a54380457c40d70a6bcc33b215ba","last_modified":"2026-10-02T03:30:49Z"},"updated_at":"2026-10-02T04:14:23.923188772Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"<p>ARGO HT instrument must be able to provide the following features:<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Must provide a fully automated, high-throughput proteomics platform capable of processing up to 288 samples per run</li>\n\t<li>Must provide an integrated qPCR system enabling end-to-end workflow from sample preparation to data output or pooled NGS library generation</li>\n\t<li>Must provide a total hands-on time of less than 30 minutes with simplified workflow and &lt;5-minute instrument setup</li>\n\t<li>Must provide results in &lt;6 hours for singleplex assays and &lt;15 hours for multiplex NGS assays</li>\n\t<li>Must provide cartridge-based reagent system capable of supporting up to three consecutive runs without replacement</li>\n\t<li>Must provide liquid handling system for automated sample preparation for both qPCR and NGS workflows</li>\n\t<li>Must provide integrated onboard computing with intuitive user interface for streamlined operation and workflow management</li>\n\t<li>Must provide a built-in cloud-based primary analysis software (ARGO Command Center) and secondary analysis software (NULISA Analysis Software, NAS)</li>\n\t<li>Must provide capability to transform raw data into biological insights and publication-ready results through integrated data analysis tools</li>\n\t<li>Must provide compatibility with ultra-high sensitivity NULISA&trade; assay technology enabling attomolar-level detection of protein biomarkers</li>\n\t<li>Must provide scalable multiplexing capability supporting singleplex to high-plex (100s&ndash;1000s of targets) biomarker analysis</li>\n\t<li>Must provide broad sample compatibility including plasma, serum, cerebrospinal fluid (CSF), urine, and cell culture media</li>\n\t<li>Must provide an application programming interface (API) available for custom method development and instrument control</li>\n\t<li>Must provide compliance with major regulatory and safety standards including EMC, UL, CE, WEEE, ISO 13485, and ISO 9001</li>\n\t<li>Must provide operating conditions supporting 15&ndash;24&deg;C temperature range and 40&ndash;80% non-condensing humidity</li>\n\t<li>Must provide electrical compatibility with 100&ndash;240 V power supply, 50&ndash;60 Hz, and maximum power consumption of 1500 watts</li>\n\t<li>Must provide instrument footprint no larger than 1143 mm (W) &times; 661 mm (D) &times; 1016 mm (H) and weight no heavier than 250 kg</li>\n</ul>\n\n<p>Delivery must be within 90 days from award</p>","text":"ARGO HT instrument must be able to provide the following features:\n\n• Must provide a fully automated, high-throughput proteomics platform capable of processing up to 288 samples per run\n\n• Must provide an integrated qPCR system enabling end-to-end workflow from sample preparation to data output or pooled NGS library generation\n\n• Must provide a total hands-on time of less than 30 minutes with simplified workflow and <5-minute instrument setup\n\n• Must provide results in <6 hours for singleplex assays and <15 hours for multiplex NGS assays\n\n• Must provide cartridge-based reagent system capable of supporting up to three consecutive runs without replacement\n\n• Must provide liquid handling system for automated sample preparation for both qPCR and NGS workflows\n\n• Must provide integrated onboard computing with intuitive user interface for streamlined operation and workflow management\n\n• Must provide a built-in cloud-based primary analysis software (ARGO Command Center) and secondary analysis software (NULISA Analysis Software, NAS)\n\n• Must provide capability to transform raw data into biological insights and publication-ready results through integrated data analysis tools\n\n• Must provide compatibility with ultra-high sensitivity NULISA™ assay technology enabling attomolar-level detection of protein biomarkers\n\n• Must provide scalable multiplexing capability supporting singleplex to high-plex (100s–1000s of targets) biomarker analysis\n\n• Must provide broad sample compatibility including plasma, serum, cerebrospinal fluid (CSF), urine, and cell culture media\n\n• Must provide an application programming interface (API) available for custom method development and instrument control\n\n• Must provide compliance with major regulatory and safety standards including EMC, UL, CE, WEEE, ISO 13485, and ISO 9001\n\n• Must provide operating conditions supporting 15–24°C temperature range and 40–80% non-condensing humidity\n\n• Must provide electrical compatibility with 100–240 V power supply, 50–60 Hz, and maximum power consumption of 1500 watts\n\n• Must provide instrument footprint no larger than 1143 mm (W) × 661 mm (D) × 1016 mm (H) and weight no heavier than 250 kg\n\nDelivery must be within 90 days from award","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"75N98026Q01157","place_of_performance":{"zip":"20892","city":{"name":"Bethesda"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"6640"}],"due_at":"2026-09-17T13:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T13:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-03T05:57:49.555909Z","principal_notice_id":"b8edf08457d54b63b193016f93f958f5","description":{"text":"ARGO HT instrument must be able to provide the following features:\n\n• Must provide a fully automated, high-throughput proteomics platform capable of processing up to 288 samples per run\n\n• Must provide an integrated qPCR system enabling end-to-end workflow from sample preparation to data output or pooled NGS library generation\n\n• Must provide a total hands-on time of less than 30 minutes with simplified workflow and <5-minute instrument setup\n\n• Must provide results in <6 hours for singleplex assays and <15 hours for multiplex NGS assays\n\n• Must provide cartridge-based reagent system capable of supporting up to three consecutive runs without replacement\n\n• Must provide liquid handling system for automated sample preparation for both qPCR and NGS workflows\n\n• Must provide integrated onboard computing with intuitive user interface for streamlined operation and workflow management\n\n• Must provide a built-in cloud-based primary analysis software (ARGO Command Center) and secondary analysis software (NULISA Analysis Software, NAS)\n\n• Must provide capability to transform raw data into biological insights and publication-ready results through integrated data analysis tools\n\n• Must provide compatibility with ultra-high sensitivity NULISA™ assay technology enabling attomolar-level detection of protein biomarkers\n\n• Must provide scalable multiplexing capability supporting singleplex to high-plex (100s–1000s of targets) biomarker analysis\n\n• Must provide broad sample compatibility including plasma, serum, cerebrospinal fluid (CSF), urine, and cell culture media\n\n• Must provide an application programming interface (API) available for custom method development and instrument control\n\n• Must provide compliance with major regulatory and safety standards including EMC, UL, CE, WEEE, ISO 13485, and ISO 9001\n\n• Must provide operating conditions supporting 15–24°C temperature range and 40–80% non-condensing humidity\n\n• Must provide electrical compatibility with 100–240 V power supply, 50–60 Hz, and maximum power consumption of 1500 watts\n\n• Must provide instrument footprint no larger than 1143 mm (W) × 661 mm (D) × 1016 mm (H) and weight no heavier than 250 kg\n\nDelivery must be within 90 days from award","html":"<p>ARGO HT instrument must be able to provide the following features:<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Must provide a fully automated, high-throughput proteomics platform capable of processing up to 288 samples per run</li>\n\t<li>Must provide an integrated qPCR system enabling end-to-end workflow from sample preparation to data output or pooled NGS library generation</li>\n\t<li>Must provide a total hands-on time of less than 30 minutes with simplified workflow and &lt;5-minute instrument setup</li>\n\t<li>Must provide results in &lt;6 hours for singleplex assays and &lt;15 hours for multiplex NGS assays</li>\n\t<li>Must provide cartridge-based reagent system capable of supporting up to three consecutive runs without replacement</li>\n\t<li>Must provide liquid handling system for automated sample preparation for both qPCR and NGS workflows</li>\n\t<li>Must provide integrated onboard computing with intuitive user interface for streamlined operation and workflow management</li>\n\t<li>Must provide a built-in cloud-based primary analysis software (ARGO Command Center) and secondary analysis software (NULISA Analysis Software, NAS)</li>\n\t<li>Must provide capability to transform raw data into biological insights and publication-ready results through integrated data analysis tools</li>\n\t<li>Must provide compatibility with ultra-high sensitivity NULISA&trade; assay technology enabling attomolar-level detection of protein biomarkers</li>\n\t<li>Must provide scalable multiplexing capability supporting singleplex to high-plex (100s&ndash;1000s of targets) biomarker analysis</li>\n\t<li>Must provide broad sample compatibility including plasma, serum, cerebrospinal fluid (CSF), urine, and cell culture media</li>\n\t<li>Must provide an application programming interface (API) available for custom method development and instrument control</li>\n\t<li>Must provide compliance with major regulatory and safety standards including EMC, UL, CE, WEEE, ISO 13485, and ISO 9001</li>\n\t<li>Must provide operating conditions supporting 15&ndash;24&deg;C temperature range and 40&ndash;80% non-condensing humidity</li>\n\t<li>Must provide electrical compatibility with 100&ndash;240 V power supply, 50&ndash;60 Hz, and maximum power consumption of 1500 watts</li>\n\t<li>Must provide instrument footprint no larger than 1143 mm (W) &times; 661 mm (D) &times; 1016 mm (H) and weight no heavier than 250 kg</li>\n</ul>\n\n<p>Delivery must be within 90 days from award</p>","origin":"detail"},"contacts":[{"name":"Brian Lind","role":"primary","email":"brian.lind@nih.gov","phone":"0000000000"}],"place_of_performance":{"zip":"20892","city":{"name":"Bethesda"},"state":{"code":"MD"},"country":{"code":"USA"}},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"5e690a80cb64454ab17c66374dcb456e","name":"Competitive COMBINED SYNOPSIS (006).pdf","kind":"file","mime_type":".pdf","size_bytes":123884,"posted_at":"2026-09-08T13:26:21.688Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5e690a80cb64454ab17c66374dcb456e/download","mirrored":false}],"awards":[],"related":[{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"NOIOD27000713","latest_notice_id":"a3fe6af21d9943e1a009483e9b326b40","title":"Notice of Intent to Sole Source – Werfen USA LLC – ACL TOP 750 Analyzers kits and reagents","solicitation_number":"NOI-OD-27-000713","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"J066","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98026Q00083","latest_notice_id":"32e71d66f9cf4440835ca571c1834aac","title":"ChemiDoc Go Imaging System","solicitation_number":"75N98026Q00083","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-28T14:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"state":"CA","county":"06013","county_name":"Contra Costa County","city":"0633308","city_name":"Hercules","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}