{"canonical":"https://sealedbidder.com/opportunities/75n98026q01138","key":"75N98026Q01138","url":"https://sealedbidder.com/opportunities/75n98026q01138","title":"Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system","solicitation_number":"75N98026Q01138","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-09-09T13:00:00Z","first_posted":"2026-09-02","last_posted":"2026-09-02","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"NATIONAL INSTITUTES OF HEALTH","office":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":"2407125","place_city_name":"Bethesda","winner":null,"award_amount":null,"publications":[{"notice_id":"e02fa0cb6f074b6aa1bede71a30c598f","title":"Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system","solicitation_number":"75N98026Q01138","notice_type":"p","base_type":"p","posted":"2026-09-02","posted_at":"2026-09-03T03:23:41.137Z","due_at":"2026-09-09T13:00:00Z","due_date":"2026-09-09","cancelled":false,"archived":true,"archive_date":"2026-09-24","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e02fa0cb6f074b6aa1bede71a30c598f/view","enriched":true,"history":[{"index":1,"title":"Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-03T03:23:41.137Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"e02fa0cb6f074b6aa1bede71a30c598f","solicitation_number":"75N98026Q01138"}]}],"latest_notice_id":"e02fa0cb6f074b6aa1bede71a30c598f","first_type":"p","notices":[{"dates":{"posted":"2026-09-02","posted_at":"2026-09-03T03:23:41.137Z","created_at":"2026-09-03T03:15:49.668Z","modified_at":"2026-09-03T03:23:41.140Z","response_deadline":{"raw":"2026-09-09T09:00:00-04:00","utc":"2026-09-09T13:00:00Z","date":"2026-09-09","time":"09:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e02fa0cb6f074b6aa1bede71a30c598f/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system","agency":{"office":{"code":"75N980","name":"NATIONAL INSTITUTES OF HEALTH OLAO"},"subtier":{"code":"7529","name":"NATIONAL INSTITUTES OF HEALTH"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-09-24","archive_type":"auto15"},"history":[{"index":1,"title":"Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-03T03:23:41.137Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"e02fa0cb6f074b6aa1bede71a30c598f","solicitation_number":"75N98026Q01138"}],"contacts":[{"name":"MAI VENSON","role":"primary","email":"vensonm@mail.nih.gov"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"e02fa0cb6f074b6aa1bede71a30c598f","lineage_id":"e02fa0cb6f074b6aa1bede71a30c598f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-17T02:01:28.848502923Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"95a38dcc808142de51137f8402e52049-29\"","fetched_at":"2026-09-24T04:21:46.782462570Z","row_sha256":"8816e1739e055ab131ecce29b07e97c6f4a5076cb9abad5873709661ab381b15","last_modified":"2026-09-24T03:30:47Z"},"updated_at":"2026-09-24T04:21:46.782462570Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"<p>Notice of Intent: Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system.</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; (75N98026Q01138)</p>\n\n<p>The National Institutes of Health (NIH) intends to award a Firm-Fixed-Price Purchase Order to Bridge12 Technologies under the authority of FAR 6.302-1, <em>Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements</em>.</p>\n\n<p>The National Institutes of Health (NIH), [Institute/Center], intends to solicit and negotiate on a sole-source basis with&nbsp;<strong>Bridge12 Technologies, Inc.</strong>&nbsp;for the acquisition of an automated high-velocity microsecond freeze hyper-quenching system for use with Q-band electron paramagnetic resonance (EPR) research applications.</p>\n\n<p>The Government requires a rapid mix/freeze-quench system capable of achieving a&nbsp;<strong>dead time of less than or equal to 500 microseconds (&le; 0.5 milliseconds)</strong>&nbsp;and compatible with Q-band EPR applications. This rapid dead-time capability is a critical minimum technical requirement because the system will be used to capture and preserve short-lived chemical intermediates and transient reaction states that would not be adequately resolved using conventional millisecond-scale freeze-quench technology.</p>\n\n<p><strong>Market Research</strong></p>\n\n<p>Market research was conducted through review of commercial vendor catalogs, published product specifications, technical literature, and consultation with subject matter experts within the EPR instrumentation community.</p>\n\n<p>The market research identified&nbsp;<strong>Bio-Logic</strong>&nbsp;as another commercial manufacturer offering freeze-quench instrumentation. However, published Bio-Logic specifications indicate a minimum dead time of approximately&nbsp;<strong>9 milliseconds</strong>. This performance is substantially slower than the Government&#39;s required maximum dead time of&nbsp;<strong>500 microseconds (0.5 milliseconds)</strong>&nbsp;and therefore does not satisfy the Government&#39;s minimum technical requirement.</p>\n\n<p>No additional commercial sources were identified through the Government&#39;s market research that offer a microsecond rapid mix/freeze-quench system compatible with Q-band EPR applications and capable of achieving the required &le;500-microsecond dead time.</p>\n\n<p>This notice is not a request for competitive quotations. However, any responsible source, including small business concerns (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, Veteran-Owned Small Business, Women-Owned Small Business, and Small Disadvantaged Business), that believes it can satisfy the Government&#39;s requirement may submit a capability statement demonstrating its ability to provide a product that meets the Government&#39;s minimum technical requirements. Capability statements must include sufficient documentation to establish the ability to furnish an equivalent system.</p>\n\n<p>A determination by the Government not to compete this proposed acquisition based upon responses to this notice is solely within the discretion of the Government.</p>\n\n<p>Responses must be submitted via email to vensonm@mail.nih.gov no later than <strong>9:00 a.m. EDT on September 09, 2026</strong>. It is anticipated that an award will be issued approximately five (5) days after the closing date of this notice, provided no acceptable capability statements are received.</p>","text":"Notice of Intent: Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system.\n\n(75N98026Q01138)\n\nThe National Institutes of Health (NIH) intends to award a Firm-Fixed-Price Purchase Order to Bridge12 Technologies under the authority of FAR 6.302-1, Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements.\n\nThe National Institutes of Health (NIH), [Institute/Center], intends to solicit and negotiate on a sole-source basis with Bridge12 Technologies, Inc. for the acquisition of an automated high-velocity microsecond freeze hyper-quenching system for use with Q-band electron paramagnetic resonance (EPR) research applications.\n\nThe Government requires a rapid mix/freeze-quench system capable of achieving a dead time of less than or equal to 500 microseconds (≤ 0.5 milliseconds) and compatible with Q-band EPR applications. This rapid dead-time capability is a critical minimum technical requirement because the system will be used to capture and preserve short-lived chemical intermediates and transient reaction states that would not be adequately resolved using conventional millisecond-scale freeze-quench technology.\n\nMarket Research\n\nMarket research was conducted through review of commercial vendor catalogs, published product specifications, technical literature, and consultation with subject matter experts within the EPR instrumentation community.\n\nThe market research identified Bio-Logic as another commercial manufacturer offering freeze-quench instrumentation. However, published Bio-Logic specifications indicate a minimum dead time of approximately 9 milliseconds. This performance is substantially slower than the Government's required maximum dead time of 500 microseconds (0.5 milliseconds) and therefore does not satisfy the Government's minimum technical requirement.\n\nNo additional commercial sources were identified through the Government's market research that offer a microsecond rapid mix/freeze-quench system compatible with Q-band EPR applications and capable of achieving the required ≤500-microsecond dead time.\n\nThis notice is not a request for competitive quotations. However, any responsible source, including small business concerns (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, Veteran-Owned Small Business, Women-Owned Small Business, and Small Disadvantaged Business), that believes it can satisfy the Government's requirement may submit a capability statement demonstrating its ability to provide a product that meets the Government's minimum technical requirements. Capability statements must include sufficient documentation to establish the ability to furnish an equivalent system.\n\nA determination by the Government not to compete this proposed acquisition based upon responses to this notice is solely within the discretion of the Government.\n\nResponses must be submitted via email to vensonm@mail.nih.gov no later than 9:00 a.m. EDT on September 09, 2026. It is anticipated that an award will be issued approximately five (5) days after the closing date of this notice, provided no acceptable capability statements are received.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"75N98026Q01138","place_of_performance":{"zip":"20892","city":{"name":"Bethesda"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"6640"}],"due_at":"2026-09-09T13:00:00Z","due_date":"2026-09-09","closes_at":"2026-09-09T13:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-25T06:24:04.566710Z","principal_notice_id":"e02fa0cb6f074b6aa1bede71a30c598f","description":{"text":"Notice of Intent: Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system.\n\n(75N98026Q01138)\n\nThe National Institutes of Health (NIH) intends to award a Firm-Fixed-Price Purchase Order to Bridge12 Technologies under the authority of FAR 6.302-1, Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements.\n\nThe National Institutes of Health (NIH), [Institute/Center], intends to solicit and negotiate on a sole-source basis with Bridge12 Technologies, Inc. for the acquisition of an automated high-velocity microsecond freeze hyper-quenching system for use with Q-band electron paramagnetic resonance (EPR) research applications.\n\nThe Government requires a rapid mix/freeze-quench system capable of achieving a dead time of less than or equal to 500 microseconds (≤ 0.5 milliseconds) and compatible with Q-band EPR applications. This rapid dead-time capability is a critical minimum technical requirement because the system will be used to capture and preserve short-lived chemical intermediates and transient reaction states that would not be adequately resolved using conventional millisecond-scale freeze-quench technology.\n\nMarket Research\n\nMarket research was conducted through review of commercial vendor catalogs, published product specifications, technical literature, and consultation with subject matter experts within the EPR instrumentation community.\n\nThe market research identified Bio-Logic as another commercial manufacturer offering freeze-quench instrumentation. However, published Bio-Logic specifications indicate a minimum dead time of approximately 9 milliseconds. This performance is substantially slower than the Government's required maximum dead time of 500 microseconds (0.5 milliseconds) and therefore does not satisfy the Government's minimum technical requirement.\n\nNo additional commercial sources were identified through the Government's market research that offer a microsecond rapid mix/freeze-quench system compatible with Q-band EPR applications and capable of achieving the required ≤500-microsecond dead time.\n\nThis notice is not a request for competitive quotations. However, any responsible source, including small business concerns (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, Veteran-Owned Small Business, Women-Owned Small Business, and Small Disadvantaged Business), that believes it can satisfy the Government's requirement may submit a capability statement demonstrating its ability to provide a product that meets the Government's minimum technical requirements. Capability statements must include sufficient documentation to establish the ability to furnish an equivalent system.\n\nA determination by the Government not to compete this proposed acquisition based upon responses to this notice is solely within the discretion of the Government.\n\nResponses must be submitted via email to vensonm@mail.nih.gov no later than 9:00 a.m. EDT on September 09, 2026. It is anticipated that an award will be issued approximately five (5) days after the closing date of this notice, provided no acceptable capability statements are received.","html":"<p>Notice of Intent: Bridge12 Technologies automated high-velocity microsecond freeze hyper-quenching system.</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; (75N98026Q01138)</p>\n\n<p>The National Institutes of Health (NIH) intends to award a Firm-Fixed-Price Purchase Order to Bridge12 Technologies under the authority of FAR 6.302-1, <em>Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements</em>.</p>\n\n<p>The National Institutes of Health (NIH), [Institute/Center], intends to solicit and negotiate on a sole-source basis with&nbsp;<strong>Bridge12 Technologies, Inc.</strong>&nbsp;for the acquisition of an automated high-velocity microsecond freeze hyper-quenching system for use with Q-band electron paramagnetic resonance (EPR) research applications.</p>\n\n<p>The Government requires a rapid mix/freeze-quench system capable of achieving a&nbsp;<strong>dead time of less than or equal to 500 microseconds (&le; 0.5 milliseconds)</strong>&nbsp;and compatible with Q-band EPR applications. This rapid dead-time capability is a critical minimum technical requirement because the system will be used to capture and preserve short-lived chemical intermediates and transient reaction states that would not be adequately resolved using conventional millisecond-scale freeze-quench technology.</p>\n\n<p><strong>Market Research</strong></p>\n\n<p>Market research was conducted through review of commercial vendor catalogs, published product specifications, technical literature, and consultation with subject matter experts within the EPR instrumentation community.</p>\n\n<p>The market research identified&nbsp;<strong>Bio-Logic</strong>&nbsp;as another commercial manufacturer offering freeze-quench instrumentation. However, published Bio-Logic specifications indicate a minimum dead time of approximately&nbsp;<strong>9 milliseconds</strong>. This performance is substantially slower than the Government&#39;s required maximum dead time of&nbsp;<strong>500 microseconds (0.5 milliseconds)</strong>&nbsp;and therefore does not satisfy the Government&#39;s minimum technical requirement.</p>\n\n<p>No additional commercial sources were identified through the Government&#39;s market research that offer a microsecond rapid mix/freeze-quench system compatible with Q-band EPR applications and capable of achieving the required &le;500-microsecond dead time.</p>\n\n<p>This notice is not a request for competitive quotations. However, any responsible source, including small business concerns (e.g., 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, Veteran-Owned Small Business, Women-Owned Small Business, and Small Disadvantaged Business), that believes it can satisfy the Government&#39;s requirement may submit a capability statement demonstrating its ability to provide a product that meets the Government&#39;s minimum technical requirements. Capability statements must include sufficient documentation to establish the ability to furnish an equivalent system.</p>\n\n<p>A determination by the Government not to compete this proposed acquisition based upon responses to this notice is solely within the discretion of the Government.</p>\n\n<p>Responses must be submitted via email to vensonm@mail.nih.gov no later than <strong>9:00 a.m. EDT on September 09, 2026</strong>. It is anticipated that an award will be issued approximately five (5) days after the closing date of this notice, provided no acceptable capability statements are received.</p>","origin":"detail"},"contacts":[{"name":"MAI VENSON","role":"primary","email":"vensonm@mail.nih.gov"}],"place_of_performance":{"zip":"20892","city":{"name":"Bethesda"},"state":{"code":"MD"},"country":{"code":"USA"}},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[],"awards":[],"related":[{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"NOIOD27000713","latest_notice_id":"a3fe6af21d9943e1a009483e9b326b40","title":"Notice of Intent to Sole Source – Werfen USA LLC – ACL TOP 750 Analyzers kits and reagents","solicitation_number":"NOI-OD-27-000713","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"J066","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98026Q00083","latest_notice_id":"32e71d66f9cf4440835ca571c1834aac","title":"ChemiDoc Go Imaging System","solicitation_number":"75N98026Q00083","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-28T14:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"state":"CA","county":"06013","county_name":"Contra Costa County","city":"0633308","city_name":"Hercules","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}