{"canonical":"https://sealedbidder.com/opportunities/75n98026q00794","key":"75N98026Q00794","url":"https://sealedbidder.com/opportunities/75n98026q00794","title":"Tokai Hit STXG-GSI2X stage top incubator for Leica Stellaris STED microscope","solicitation_number":"75N98026Q00794","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-25T13:00:00Z","first_posted":"2026-07-15","last_posted":"2026-07-15","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"NATIONAL INSTITUTES OF HEALTH","office":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":"SBA","place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":"2407125","place_city_name":"Bethesda","winner":null,"award_amount":null,"publications":[{"notice_id":"7f0309dced09447697a2aca2279013b4","title":"Tokai Hit STXG-GSI2X stage top incubator for Leica Stellaris STED microscope","solicitation_number":"75N98026Q00794","notice_type":"k","base_type":"k","posted":"2026-07-15","posted_at":"2026-07-15T13:25:25.772Z","due_at":"2026-07-25T13:00:00Z","due_date":"2026-07-25","cancelled":false,"archived":true,"archive_date":"2026-07-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7f0309dced09447697a2aca2279013b4/view","enriched":true,"history":[{"index":3,"title":"Tokai Hit STXG-GSI2X stage top incubator for Leica Stellaris STED microscope","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T13:25:25.772Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7f0309dced09447697a2aca2279013b4","solicitation_number":"75N98026Q00794"}]}],"latest_notice_id":"7f0309dced09447697a2aca2279013b4","first_type":"k","notices":[{"dates":{"posted":"2026-07-15","posted_at":"2026-07-15T13:25:25.772Z","created_at":"2026-07-15T12:58:52.678Z","modified_at":"2026-07-26T04:13:13.097Z","response_deadline":{"raw":"2026-07-25T09:00:00-04:00","utc":"2026-07-25T13:00:00Z","date":"2026-07-25","time":"09:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7f0309dced09447697a2aca2279013b4/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Tokai Hit STXG-GSI2X stage top incubator for Leica Stellaris STED microscope","agency":{"office":{"code":"75N980","name":"NATIONAL INSTITUTES OF HEALTH OLAO"},"subtier":{"code":"7529","name":"NATIONAL INSTITUTES OF HEALTH"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"organization_id":"100189057","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-26","archive_type":"auto_custom"},"history":[{"index":3,"title":"Tokai Hit STXG-GSI2X stage top incubator for Leica Stellaris STED microscope","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T13:25:25.772Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"7f0309dced09447697a2aca2279013b4","solicitation_number":"75N98026Q00794"}],"contacts":[{"name":"John Burton","role":"primary","email":"burtonjo@mail.nih.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"7f0309dced09447697a2aca2279013b4","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"7f0309dced09447697a2aca2279013b4","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T02:52:42.911472099Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"61d2aaf4e36735d2afe4b6a511487a2aae1318dcc8a32f22ee470f41b0588df1","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T02:52:42.911472099Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Requirements:</p>\n\n<p>Provides&nbsp;accurate&nbsp;dynamic control of temperature, humidity,&nbsp;CO2&nbsp;and oxygen to&nbsp;maintain&nbsp;required cell culture conditions for live cell confocal&nbsp;and STED super-resolution&nbsp;imaging. The stage top incubator is&nbsp;required&nbsp;in order to&nbsp;perform live cell imaging with the unique resolution capabilities of&nbsp;our&nbsp;Leica Stellaris 5 STED microscope. It currently does not have a stage top incubator, and therefore, is unable to perform this type of imaging requested by NCI researchers.</p>\n\n<p>Stage top incubator&nbsp;controller must have two feedback modes, chamber temperature or specimen temperature, while it also continuously&nbsp;monitors&nbsp;the room temperature to&nbsp;maintain&nbsp;specimen temperature within set point&nbsp;anywhere&nbsp;between 25 &ndash; 50&nbsp;degrees&nbsp;Celsius. The&nbsp;built-in&nbsp;digital gas mixer&nbsp;controller&nbsp;accepts 100% CO2 from lab supply to&nbsp;regulate CO2 concentration&nbsp;at the sample, with a CO2 range of&nbsp;5.0 to 20%&nbsp;with real-time sample feedback.&nbsp;In addition, humidity is actively controlled with an&nbsp;internal humidifier to sense sample chamber humidity.&nbsp;The electrically heated stage top incubator chamber must have magnets for easy interchange of specimen holders, including inserts for&nbsp;35&nbsp;mm&nbsp;coverglass&nbsp;dish, 50/60mm&nbsp;coverglass&nbsp;dish, chamber slide,&nbsp;coverglass&nbsp;chamber, and open frame insert for imaging multi-well&nbsp;chambers. A flexible heated collar that accommodates a range of objective lens diameters must also be included.</p>\n\n<p>The components of the stage top incubator must include:&nbsp;</p>\n\n<ul>\n\t<li>Tokai&nbsp;Hit STXG-GSI2X-SET Stage Top Incubator for Super Z galvo stage (inverted microscope stands)&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Pure (100%CO2) gas use (110- 240V) for individual temperature settings to create&nbsp;optimum&nbsp;temperature and humidity conditions without difficulty for long term live cell imaging.&nbsp;&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Setting temperature range from&nbsp;25&nbsp;to 50&deg;C.&nbsp;&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Dimensions of&nbsp;112 x 87 mm&nbsp;compatible with Leica Super Z galvo stage on existing Leica Stellaris 5 STED microscope.&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>the lightest chamber (less than 140g) for Super Z&nbsp;Glavo&nbsp;stage&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>temperature controller with built-in digital gas mixer (CO2: 5.0 - 20.0%)&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Objective heater&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Magnetic Dish holder and fixing lid for 35mm, 50/60mm dish, chamber slide, slide&nbsp;glass&nbsp;and chamber slide use.&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>External Sensor, enable to autoclave repeatability for Sample Feedback regulation.&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Tokai Hit original data logging, temp/CO2 program control, software&nbsp;compatible to use with LAS-X software&nbsp;</li>\n</ul>\n\n<p></p>","text":"Requirements:\n\nProvides accurate dynamic control of temperature, humidity, CO2 and oxygen to maintain required cell culture conditions for live cell confocal and STED super-resolution imaging. The stage top incubator is required in order to perform live cell imaging with the unique resolution capabilities of our Leica Stellaris 5 STED microscope. It currently does not have a stage top incubator, and therefore, is unable to perform this type of imaging requested by NCI researchers.\n\nStage top incubator controller must have two feedback modes, chamber temperature or specimen temperature, while it also continuously monitors the room temperature to maintain specimen temperature within set point anywhere between 25 – 50 degrees Celsius. The built-in digital gas mixer controller accepts 100% CO2 from lab supply to regulate CO2 concentration at the sample, with a CO2 range of 5.0 to 20% with real-time sample feedback. In addition, humidity is actively controlled with an internal humidifier to sense sample chamber humidity. The electrically heated stage top incubator chamber must have magnets for easy interchange of specimen holders, including inserts for 35 mm coverglass dish, 50/60mm coverglass dish, chamber slide, coverglass chamber, and open frame insert for imaging multi-well chambers. A flexible heated collar that accommodates a range of objective lens diameters must also be included.\n\nThe components of the stage top incubator must include:\n\n• Tokai Hit STXG-GSI2X-SET Stage Top Incubator for Super Z galvo stage (inverted microscope stands)\n\n• Pure (100%CO2) gas use (110- 240V) for individual temperature settings to create optimum temperature and humidity conditions without difficulty for long term live cell imaging.\n\n• Setting temperature range from 25 to 50°C.\n\n• Dimensions of 112 x 87 mm compatible with Leica Super Z galvo stage on existing Leica Stellaris 5 STED microscope.\n\n• the lightest chamber (less than 140g) for Super Z Glavo stage\n\n• temperature controller with built-in digital gas mixer (CO2: 5.0 - 20.0%)\n\n• Objective heater\n\n• Magnetic Dish holder and fixing lid for 35mm, 50/60mm dish, chamber slide, slide glass and chamber slide use.\n\n• External Sensor, enable to autoclave repeatability for Sample Feedback regulation.\n\n• Tokai Hit original data logging, temp/CO2 program control, software compatible to use with LAS-X software","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"75N98026Q00794","place_of_performance":{"zip":"20892","city":{"code":"7125","name":"Bethesda"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"}],"due_at":"2026-07-25T13:00:00Z","due_date":"2026-07-25","closes_at":"2026-07-25T13:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-29T03:13:57.714553Z","principal_notice_id":"7f0309dced09447697a2aca2279013b4","description":{"text":"Requirements:\n\nProvides accurate dynamic control of temperature, humidity, CO2 and oxygen to maintain required cell culture conditions for live cell confocal and STED super-resolution imaging. The stage top incubator is required in order to perform live cell imaging with the unique resolution capabilities of our Leica Stellaris 5 STED microscope. It currently does not have a stage top incubator, and therefore, is unable to perform this type of imaging requested by NCI researchers.\n\nStage top incubator controller must have two feedback modes, chamber temperature or specimen temperature, while it also continuously monitors the room temperature to maintain specimen temperature within set point anywhere between 25 – 50 degrees Celsius. The built-in digital gas mixer controller accepts 100% CO2 from lab supply to regulate CO2 concentration at the sample, with a CO2 range of 5.0 to 20% with real-time sample feedback. In addition, humidity is actively controlled with an internal humidifier to sense sample chamber humidity. The electrically heated stage top incubator chamber must have magnets for easy interchange of specimen holders, including inserts for 35 mm coverglass dish, 50/60mm coverglass dish, chamber slide, coverglass chamber, and open frame insert for imaging multi-well chambers. A flexible heated collar that accommodates a range of objective lens diameters must also be included.\n\nThe components of the stage top incubator must include:\n\n• Tokai Hit STXG-GSI2X-SET Stage Top Incubator for Super Z galvo stage (inverted microscope stands)\n\n• Pure (100%CO2) gas use (110- 240V) for individual temperature settings to create optimum temperature and humidity conditions without difficulty for long term live cell imaging.\n\n• Setting temperature range from 25 to 50°C.\n\n• Dimensions of 112 x 87 mm compatible with Leica Super Z galvo stage on existing Leica Stellaris 5 STED microscope.\n\n• the lightest chamber (less than 140g) for Super Z Glavo stage\n\n• temperature controller with built-in digital gas mixer (CO2: 5.0 - 20.0%)\n\n• Objective heater\n\n• Magnetic Dish holder and fixing lid for 35mm, 50/60mm dish, chamber slide, slide glass and chamber slide use.\n\n• External Sensor, enable to autoclave repeatability for Sample Feedback regulation.\n\n• Tokai Hit original data logging, temp/CO2 program control, software compatible to use with LAS-X software","html":"<p>Requirements:</p>\n\n<p>Provides&nbsp;accurate&nbsp;dynamic control of temperature, humidity,&nbsp;CO2&nbsp;and oxygen to&nbsp;maintain&nbsp;required cell culture conditions for live cell confocal&nbsp;and STED super-resolution&nbsp;imaging. The stage top incubator is&nbsp;required&nbsp;in order to&nbsp;perform live cell imaging with the unique resolution capabilities of&nbsp;our&nbsp;Leica Stellaris 5 STED microscope. It currently does not have a stage top incubator, and therefore, is unable to perform this type of imaging requested by NCI researchers.</p>\n\n<p>Stage top incubator&nbsp;controller must have two feedback modes, chamber temperature or specimen temperature, while it also continuously&nbsp;monitors&nbsp;the room temperature to&nbsp;maintain&nbsp;specimen temperature within set point&nbsp;anywhere&nbsp;between 25 &ndash; 50&nbsp;degrees&nbsp;Celsius. The&nbsp;built-in&nbsp;digital gas mixer&nbsp;controller&nbsp;accepts 100% CO2 from lab supply to&nbsp;regulate CO2 concentration&nbsp;at the sample, with a CO2 range of&nbsp;5.0 to 20%&nbsp;with real-time sample feedback.&nbsp;In addition, humidity is actively controlled with an&nbsp;internal humidifier to sense sample chamber humidity.&nbsp;The electrically heated stage top incubator chamber must have magnets for easy interchange of specimen holders, including inserts for&nbsp;35&nbsp;mm&nbsp;coverglass&nbsp;dish, 50/60mm&nbsp;coverglass&nbsp;dish, chamber slide,&nbsp;coverglass&nbsp;chamber, and open frame insert for imaging multi-well&nbsp;chambers. A flexible heated collar that accommodates a range of objective lens diameters must also be included.</p>\n\n<p>The components of the stage top incubator must include:&nbsp;</p>\n\n<ul>\n\t<li>Tokai&nbsp;Hit STXG-GSI2X-SET Stage Top Incubator for Super Z galvo stage (inverted microscope stands)&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Pure (100%CO2) gas use (110- 240V) for individual temperature settings to create&nbsp;optimum&nbsp;temperature and humidity conditions without difficulty for long term live cell imaging.&nbsp;&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Setting temperature range from&nbsp;25&nbsp;to 50&deg;C.&nbsp;&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Dimensions of&nbsp;112 x 87 mm&nbsp;compatible with Leica Super Z galvo stage on existing Leica Stellaris 5 STED microscope.&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>the lightest chamber (less than 140g) for Super Z&nbsp;Glavo&nbsp;stage&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>temperature controller with built-in digital gas mixer (CO2: 5.0 - 20.0%)&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Objective heater&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Magnetic Dish holder and fixing lid for 35mm, 50/60mm dish, chamber slide, slide&nbsp;glass&nbsp;and chamber slide use.&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>External Sensor, enable to autoclave repeatability for Sample Feedback regulation.&nbsp;</li>\n</ul>\n\n<ul>\n\t<li>Tokai Hit original data logging, temp/CO2 program control, software&nbsp;compatible to use with LAS-X software&nbsp;</li>\n</ul>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"John Burton","role":"primary","email":"burtonjo@mail.nih.gov"}],"place_of_performance":{"zip":"20892","city":{"code":"7125","name":"Bethesda"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"d37e4a2c9b9d42948bff48e0d17a7218","name":"Requirement 33.docx","kind":"file","mime_type":".docx","size_bytes":17718,"posted_at":"2026-07-15T13:25:25.772Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d37e4a2c9b9d42948bff48e0d17a7218/download","mirrored":false}],"awards":[],"related":[{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"NOIOD27000713","latest_notice_id":"a3fe6af21d9943e1a009483e9b326b40","title":"Notice of Intent to Sole Source – Werfen USA LLC – ACL TOP 750 Analyzers kits and reagents","solicitation_number":"NOI-OD-27-000713","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"J066","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98026Q00083","latest_notice_id":"32e71d66f9cf4440835ca571c1834aac","title":"ChemiDoc Go Imaging System","solicitation_number":"75N98026Q00083","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-28T14:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"state":"CA","county":"06013","county_name":"Contra Costa County","city":"0633308","city_name":"Hercules","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"PCANIDDK12835","latest_notice_id":"12bcdd2c0d4b431091cd615c8259722e","title":"Liquid Chromatography System","solicitation_number":"PCA-NIDDK-12835","notice_type":"p","first_type":"p","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-28T17:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"H149","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}