{"canonical":"https://sealedbidder.com/opportunities/75n98026q00714","key":"75N98026Q00714","url":"https://sealedbidder.com/opportunities/75n98026q00714","title":"Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System","solicitation_number":"75N98026Q00714","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-20T13:00:00Z","first_posted":"2026-07-09","last_posted":"2026-07-09","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"NATIONAL INSTITUTES OF HEALTH","office":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":"2407125","place_city_name":"Bethesda","winner":null,"award_amount":null,"publications":[{"notice_id":"3200a68293ae4a1e8cf459207cf69cc5","title":"Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System","solicitation_number":"75N98026Q00714","notice_type":"k","base_type":"k","posted":"2026-07-09","posted_at":"2026-07-09T14:50:48.638Z","due_at":"2026-07-20T13:00:00Z","due_date":"2026-07-20","cancelled":false,"archived":true,"archive_date":"2026-07-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3200a68293ae4a1e8cf459207cf69cc5/view","enriched":true,"history":[{"index":3,"title":"Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-09T14:50:48.638Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3200a68293ae4a1e8cf459207cf69cc5","solicitation_number":"75N98026Q00714"}]}],"latest_notice_id":"3200a68293ae4a1e8cf459207cf69cc5","first_type":"k","notices":[{"dates":{"posted":"2026-07-09","posted_at":"2026-07-09T14:50:48.638Z","created_at":"2026-07-09T14:17:29.742Z","modified_at":"2026-07-22T03:55:45.426Z","response_deadline":{"raw":"2026-07-20T09:00:00-04:00","utc":"2026-07-20T13:00:00Z","date":"2026-07-20","time":"09:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3200a68293ae4a1e8cf459207cf69cc5/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System","agency":{"office":{"code":"75N980","name":"NATIONAL INSTITUTES OF HEALTH OLAO"},"subtier":{"code":"7529","name":"NATIONAL INSTITUTES OF HEALTH"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"organization_id":"100189057","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-21","archive_type":"auto_custom"},"history":[{"index":3,"title":"Acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-09T14:50:48.638Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3200a68293ae4a1e8cf459207cf69cc5","solicitation_number":"75N98026Q00714"}],"contacts":[{"name":"John Burton","role":"primary","email":"burtonjo@mail.nih.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"3200a68293ae4a1e8cf459207cf69cc5","lineage_id":"3200a68293ae4a1e8cf459207cf69cc5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T02:27:15.004493952Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"4dee0992a803904b056aebd14869be1974849952c759d4f737a72008b1b61dc6","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-30T02:27:15.004493952Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Requirements:</p>\n\n<p>To ensure continuity of research, NIAMS proposes the acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System. qPCR is a core technology used for nucleic acid amplification, quantification, and analysis and supports a wide range of research applications, including gene expression studies, pathogen detection, transcript quantification, and validation of experimental results. The QuantStudio 3 is the closest replacement to the current StepOnePlus systems, allowing researchers to maintain established workflows and consistency in experimental design and data interpretation. The QuantStudio 3 offers several operational advantages, including user-friendly software, compatibility with both Mac and PC platforms, touchscreen operation, and the ability to function as a standalone instrument or in conjunction with a computer. Its thermal block design is similar to the existing systems, minimizing the learning curve for users and supporting a broad range of genomic applications. In addition, the manufacturer offers trade-in credit for the current instruments, reducing the overall acquisition cost while providing access to a fully supported platform with available parts and technical support. Acquiring the QuantStudio 3 at this time will help prevent interruptions to research activities, maintain reliable and consistent data generation, and ensure that NIAMS laboratories have access to a supported and dependable qPCR platform.</p>\n\n<p>4.1 PRODUCT FEATURES/SALIENT CHARACTERISTICS The contractor shall provide one Applied Biosystems QuantStudio 3 Real-Time PCR System or an equal system that meets all the following minimum requirements. 4.1.1. System Features/Benefits The system shall: &bull; Utilize a platform providing 1 TB or storage space for data sharing at user discretion &bull; be used with online scientific apps &bull; come with desktop-based software, allowing single-plate run setup and analysis.</p>\n\n<p>4.1.2. Technical specifications &ndash; Instrument The instrument shall: &bull; have a 96 well 0.1 ml plate block format and the option to run fast protocols &lt;30 minutes &bull; not require a field service engineer for set up by end user. Set up should be easy for end user &ndash; directly out of the box. &bull; not require a computer for installation &bull; use an RNase P verification plate to verify performance &bull; not require dye calibration upon installation &bull; have dimensions fo 27 x 50 x 40 cm and be designed to maximize horizonal and vertical bench space &bull; be capable of analyzing 96 samples simultaneously in various formats incluing both 96-well plates, 8-tube strips and individual tubes &bull; the 96-well block should be made of at least 3 separated Peltier elements &ndash; VeriFlex Blocks. The maximum temperature difference programmable across the block should be 10 degrees C. 5 degrees C should be the maximum difference in temperature allowed between adjacent blocks. &bull; Support reaction volumes of 10-30 uL on 0.1mL the 96-well block &bull; Be factory calibrated with FAM, SYBR Green 1, VIC, NED, ABY, JUN, TAMRA, and ROX dyes &bull; Have melt or dissociation curves that take place in steps with deltaT varying between 0.015 degrees C and 3.66 degrees C &bull; Have a maximum block ramp rate of 9.0 degrees C/sec for the 0.1 mL block &bull; Have a block with a temperature range of 4-99.9 degrees celcius &bull; Have a heated cover with temperature range of 50-110 degreesC 2</p>\n\n<p>&bull; Have a long-lasting bright white LED source with median lifetime of at least 60,000 hours &bull; Have a CMOS imager for data acquisition and collects data for each filter combination in less than 2 seconds &bull; be used with 120-240 V outlets without modification or special plug requirements &bull; Include a heated lid assembly to heat tops of sample plates and minimize reaction evaporation.</p>\n\n<p>&nbsp;4.1.3 Technical specifications &ndash; Instrument onboard computer The system shall: &bull; Possess the capability to run in stand-alone mode, without an attached computer &bull; Include a touchscreen interface and store protocols for quick starts with no computer needed &bull; Have a touchscreen interface that enables viewing amplification plots and filtering them by sample, target and task &bull; Have a touchscreen interface that facilitates uploading of protocols or downloading of run files via a USB, local network and the Connect platform &bull; Have a touchscreen interface that allows uploading of protocols and run files directly to the Connect platform &bull; Contain onboard storage with memory capacity of 10 GB for storing 1,000-5,000 standard absolute quantification run files, and be designed for run protection in case of power outages &bull; Be able to be customized through the touchscreen for time zones and service/calibration notification settings &bull; Have a touchscreen interface that supports the creation of local user accounts with PIN-protected access that can be linked to the Connect platform to online accounts on thermofisher.com &bull; Have a touchscreen interface that allows creation and running of protocols as guests &bull; Have a touchscreen interface that allows for editing of protocols at all stages of the reaction cycle as well as block settings, temperature settings duration, ramp rate, etc. &bull; Have a touchscreen interface that allows a template to be loaded from a USB, local network or the Connect platform &bull; Have a touchscreen interface that allows user to enter reagent information &bull; Have a touchscreen interface that allows a run to be paused and during that pause for the block temperature to be set as well as for the drawer to be opened and closed &bull; Have a touchscreen interface that allows editing of sample and target assignments &bull; Have a touchscreen interface that allows the repeat of a previous run 3 &bull; Have a touchscreen interface that allows users to perform dye calibrations and view results on the touchscreen &bull; Have a touchscreen interface that allows RNase P verification runs and automatically provides pass/fail results &bull; Have a touchscreen interface that allows a user to run a self-verification test &bull; Have a touchscreen interface that allows the user to view the cure QC assessment after calibration and RNase P plate runs are finished &bull; Have a touchscreen interface that allows progress monitoring.</p>\n\n<p>&nbsp;4.1.4 Performance Requirements The instrument shall: &bull; Complete 40-cycle real-time PCR runs using fluorogenic 5&rsquo; nuclease assay and Fast chemistry in a standard 96-well plate in less than 30 minutes as well as being able to run in standard ramping mode with standard chemistry &bull; Include an OptiFlex system that combines four coupled excitation, and emission filter sets to allow multiplexing up to four unique wavelengths &bull; Support at least two reaction chemistries-TaqMan&reg; Probes and SYBR Green dye &bull; Have real-time quantitative PCR installation specifications to be able to distinguish between 5,000 and 10,000 template copies at a 99.7% confidence level.</p>\n\n<p>&nbsp;4.1.5 Software Requirements The software shall: &bull; Allow flexible customization of run protocols &bull; Allow the creation of secure templates that are locked with a password to limit modification of run setup &bull; Provide run monitoring of connected instruments &bull; Include preoptimized run protocols for applications like standard curve, relative standard curve, relative quantification of gene expression, and SNP genotyping with TaqMan&reg; or SYBR Green chemistries &bull; Include a copy of free software to analyze data for absolute and relative quantification, SNP detection and other assays. &bull; Collect information on both TaqMan and SYBR assays in the same run &bull; Have a genotyping optimization tool that uses real-time data &bull; Provide raw fluorescence data and multicomponent data for troubleshooting &bull; Allow conversion of protocols for the Applied Biosystems StepOnePlus and 7500 to the QuantStudio 3 system protocols &bull; Allow batch analysis of up to 500 experiments simultaneously &bull; Can control the instrument and analyze data from a remote computer on the same network 4 &bull; Provide status monitoring of connected instruments and real-time plots STATEMENT OF NEED (SON) &bull; Have the ability to send user notifications when a run is started, stopped or has an error &bull; Allow registered users of the Connect platform to monitor any connected instrument &bull; Allow users to run an assay plate without performing plate setup prior to beginning of run and to correct plate set up after the run &bull; Allow export of all run results to excel and save graphs as .jpg files &bull; Provide the ability to import a standard curve from one plate for analysis of another plate of the same instrument type &bull; Allow for the selection of endogenous controls for gene expression experiments &bull; Include statistical analysis tools including box-whisker plots, scatter plots and heat maps &bull; Allow preselection of data to export and the location of the exported file &bull; Allow for command-line functions for batch exporting of analyzed run files &bull; Allow users to save predefined analysis settings for auto-exporting run data into format of choice &bull; Contain online high-resolution melt application so user can specify number of clusters/variants and save defined controls and analysis setting.</p>\n\n<p>&nbsp;4.1.6 Instrument Ecosystem The instrument ecosystem shall: &bull; Be part of a desktop ecosystem that consists of a suite of qPCR applications. Instrument data can be grouped (multi-plate) for relative quantitation, SNP genotyping, standard curve, HRM analysis, and presence/absence analysis. &bull; Be part of the Connect platform &bull; Be able to connect to the Connect platform for run setup download and data uploads &bull; Allow a run to be monitored by a web browser or mobile device &bull; Allow batch-analysis of up to 500 experiments simultaneously through an online relative quantitation module &bull; Provide an endogenous control selection tool for gene expression experiments in both the desktop and online quantitation software &bull; Contain statistical anaylsis tools with both the desktop and online quantitation software &bull; Contain a genotyping optimization tool that uses real-time data to pick the best cycle number for calling genotype in both the desktop and online genotyping software &bull; Allow the user to specify number of clusters/variants and save defined controls and analysis settings with both desktop and online software.</p>\n\n<p>&nbsp;4.1.7. &nbsp;Design 5 The system shall: &bull; Have an application programming interface (API) included that allows programming routines to be developed for controlling the instrument &bull; Be cUL, UL, CE, C-TICK, and WEEE compliant &bull; Be developed and manufactured in a facility with quality system requirements that comply with ISO 13485 standards and ISO 9001 standards 4.1.8 Gene expression profiling &bull; Users shall be able to select from more than 61,000 predesigned human, mouse and rat Applied BiosystemsTMTaqMan&reg; Assays.</p>\n\n<p>&nbsp;4.1.9 Able to accept the trade-in of Model STEPONEPLUS. Serial number 272008444 4.1.10 Must be compatible with protocols from Applied Biosystems StepOnePlus Real Time PCR (qPCR) allowing for consistency in experimental set-up 4.2 DELIVERY / INSTALLATION The contractor shall deliver and install the equipment within thirty (30) calendar days after receipt of award.</p>\n\n<p></p>","text":"Requirements:\n\nTo ensure continuity of research, NIAMS proposes the acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System. qPCR is a core technology used for nucleic acid amplification, quantification, and analysis and supports a wide range of research applications, including gene expression studies, pathogen detection, transcript quantification, and validation of experimental results. The QuantStudio 3 is the closest replacement to the current StepOnePlus systems, allowing researchers to maintain established workflows and consistency in experimental design and data interpretation. The QuantStudio 3 offers several operational advantages, including user-friendly software, compatibility with both Mac and PC platforms, touchscreen operation, and the ability to function as a standalone instrument or in conjunction with a computer. Its thermal block design is similar to the existing systems, minimizing the learning curve for users and supporting a broad range of genomic applications. In addition, the manufacturer offers trade-in credit for the current instruments, reducing the overall acquisition cost while providing access to a fully supported platform with available parts and technical support. Acquiring the QuantStudio 3 at this time will help prevent interruptions to research activities, maintain reliable and consistent data generation, and ensure that NIAMS laboratories have access to a supported and dependable qPCR platform.\n\n4.1 PRODUCT FEATURES/SALIENT CHARACTERISTICS The contractor shall provide one Applied Biosystems QuantStudio 3 Real-Time PCR System or an equal system that meets all the following minimum requirements. 4.1.1. System Features/Benefits The system shall: • Utilize a platform providing 1 TB or storage space for data sharing at user discretion • be used with online scientific apps • come with desktop-based software, allowing single-plate run setup and analysis.\n\n4.1.2. Technical specifications – Instrument The instrument shall: • have a 96 well 0.1 ml plate block format and the option to run fast protocols <30 minutes • not require a field service engineer for set up by end user. Set up should be easy for end user – directly out of the box. • not require a computer for installation • use an RNase P verification plate to verify performance • not require dye calibration upon installation • have dimensions fo 27 x 50 x 40 cm and be designed to maximize horizonal and vertical bench space • be capable of analyzing 96 samples simultaneously in various formats incluing both 96-well plates, 8-tube strips and individual tubes • the 96-well block should be made of at least 3 separated Peltier elements – VeriFlex Blocks. The maximum temperature difference programmable across the block should be 10 degrees C. 5 degrees C should be the maximum difference in temperature allowed between adjacent blocks. • Support reaction volumes of 10-30 uL on 0.1mL the 96-well block • Be factory calibrated with FAM, SYBR Green 1, VIC, NED, ABY, JUN, TAMRA, and ROX dyes • Have melt or dissociation curves that take place in steps with deltaT varying between 0.015 degrees C and 3.66 degrees C • Have a maximum block ramp rate of 9.0 degrees C/sec for the 0.1 mL block • Have a block with a temperature range of 4-99.9 degrees celcius • Have a heated cover with temperature range of 50-110 degreesC 2\n\n• Have a long-lasting bright white LED source with median lifetime of at least 60,000 hours • Have a CMOS imager for data acquisition and collects data for each filter combination in less than 2 seconds • be used with 120-240 V outlets without modification or special plug requirements • Include a heated lid assembly to heat tops of sample plates and minimize reaction evaporation.\n\n4.1.3 Technical specifications – Instrument onboard computer The system shall: • Possess the capability to run in stand-alone mode, without an attached computer • Include a touchscreen interface and store protocols for quick starts with no computer needed • Have a touchscreen interface that enables viewing amplification plots and filtering them by sample, target and task • Have a touchscreen interface that facilitates uploading of protocols or downloading of run files via a USB, local network and the Connect platform • Have a touchscreen interface that allows uploading of protocols and run files directly to the Connect platform • Contain onboard storage with memory capacity of 10 GB for storing 1,000-5,000 standard absolute quantification run files, and be designed for run protection in case of power outages • Be able to be customized through the touchscreen for time zones and service/calibration notification settings • Have a touchscreen interface that supports the creation of local user accounts with PIN-protected access that can be linked to the Connect platform to online accounts on thermofisher.com • Have a touchscreen interface that allows creation and running of protocols as guests • Have a touchscreen interface that allows for editing of protocols at all stages of the reaction cycle as well as block settings, temperature settings duration, ramp rate, etc. • Have a touchscreen interface that allows a template to be loaded from a USB, local network or the Connect platform • Have a touchscreen interface that allows user to enter reagent information • Have a touchscreen interface that allows a run to be paused and during that pause for the block temperature to be set as well as for the drawer to be opened and closed • Have a touchscreen interface that allows editing of sample and target assignments • Have a touchscreen interface that allows the repeat of a previous run 3 • Have a touchscreen interface that allows users to perform dye calibrations and view results on the touchscreen • Have a touchscreen interface that allows RNase P verification runs and automatically provides pass/fail results • Have a touchscreen interface that allows a user to run a self-verification test • Have a touchscreen interface that allows the user to view the cure QC assessment after calibration and RNase P plate runs are finished • Have a touchscreen interface that allows progress monitoring.\n\n4.1.4 Performance Requirements The instrument shall: • Complete 40-cycle real-time PCR runs using fluorogenic 5’ nuclease assay and Fast chemistry in a standard 96-well plate in less than 30 minutes as well as being able to run in standard ramping mode with standard chemistry • Include an OptiFlex system that combines four coupled excitation, and emission filter sets to allow multiplexing up to four unique wavelengths • Support at least two reaction chemistries-TaqMan® Probes and SYBR Green dye • Have real-time quantitative PCR installation specifications to be able to distinguish between 5,000 and 10,000 template copies at a 99.7% confidence level.\n\n4.1.5 Software Requirements The software shall: • Allow flexible customization of run protocols • Allow the creation of secure templates that are locked with a password to limit modification of run setup • Provide run monitoring of connected instruments • Include preoptimized run protocols for applications like standard curve, relative standard curve, relative quantification of gene expression, and SNP genotyping with TaqMan® or SYBR Green chemistries • Include a copy of free software to analyze data for absolute and relative quantification, SNP detection and other assays. • Collect information on both TaqMan and SYBR assays in the same run • Have a genotyping optimization tool that uses real-time data • Provide raw fluorescence data and multicomponent data for troubleshooting • Allow conversion of protocols for the Applied Biosystems StepOnePlus and 7500 to the QuantStudio 3 system protocols • Allow batch analysis of up to 500 experiments simultaneously • Can control the instrument and analyze data from a remote computer on the same network 4 • Provide status monitoring of connected instruments and real-time plots STATEMENT OF NEED (SON) • Have the ability to send user notifications when a run is started, stopped or has an error • Allow registered users of the Connect platform to monitor any connected instrument • Allow users to run an assay plate without performing plate setup prior to beginning of run and to correct plate set up after the run • Allow export of all run results to excel and save graphs as .jpg files • Provide the ability to import a standard curve from one plate for analysis of another plate of the same instrument type • Allow for the selection of endogenous controls for gene expression experiments • Include statistical analysis tools including box-whisker plots, scatter plots and heat maps • Allow preselection of data to export and the location of the exported file • Allow for command-line functions for batch exporting of analyzed run files • Allow users to save predefined analysis settings for auto-exporting run data into format of choice • Contain online high-resolution melt application so user can specify number of clusters/variants and save defined controls and analysis setting.\n\n4.1.6 Instrument Ecosystem The instrument ecosystem shall: • Be part of a desktop ecosystem that consists of a suite of qPCR applications. Instrument data can be grouped (multi-plate) for relative quantitation, SNP genotyping, standard curve, HRM analysis, and presence/absence analysis. • Be part of the Connect platform • Be able to connect to the Connect platform for run setup download and data uploads • Allow a run to be monitored by a web browser or mobile device • Allow batch-analysis of up to 500 experiments simultaneously through an online relative quantitation module • Provide an endogenous control selection tool for gene expression experiments in both the desktop and online quantitation software • Contain statistical anaylsis tools with both the desktop and online quantitation software • Contain a genotyping optimization tool that uses real-time data to pick the best cycle number for calling genotype in both the desktop and online genotyping software • Allow the user to specify number of clusters/variants and save defined controls and analysis settings with both desktop and online software.\n\n4.1.7. Design 5 The system shall: • Have an application programming interface (API) included that allows programming routines to be developed for controlling the instrument • Be cUL, UL, CE, C-TICK, and WEEE compliant • Be developed and manufactured in a facility with quality system requirements that comply with ISO 13485 standards and ISO 9001 standards 4.1.8 Gene expression profiling • Users shall be able to select from more than 61,000 predesigned human, mouse and rat Applied BiosystemsTMTaqMan® Assays.\n\n4.1.9 Able to accept the trade-in of Model STEPONEPLUS. Serial number 272008444 4.1.10 Must be compatible with protocols from Applied Biosystems StepOnePlus Real Time PCR (qPCR) allowing for consistency in experimental set-up 4.2 DELIVERY / INSTALLATION The contractor shall deliver and install the equipment within thirty (30) calendar days after receipt of award.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"75N98026Q00714","place_of_performance":{"zip":"20892","city":{"code":"7125","name":"Bethesda"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"}],"due_at":"2026-07-20T13:00:00Z","due_date":"2026-07-20","closes_at":"2026-07-20T13:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-30T03:29:01.199186Z","principal_notice_id":"3200a68293ae4a1e8cf459207cf69cc5","description":{"text":"Requirements:\n\nTo ensure continuity of research, NIAMS proposes the acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System. qPCR is a core technology used for nucleic acid amplification, quantification, and analysis and supports a wide range of research applications, including gene expression studies, pathogen detection, transcript quantification, and validation of experimental results. The QuantStudio 3 is the closest replacement to the current StepOnePlus systems, allowing researchers to maintain established workflows and consistency in experimental design and data interpretation. The QuantStudio 3 offers several operational advantages, including user-friendly software, compatibility with both Mac and PC platforms, touchscreen operation, and the ability to function as a standalone instrument or in conjunction with a computer. Its thermal block design is similar to the existing systems, minimizing the learning curve for users and supporting a broad range of genomic applications. In addition, the manufacturer offers trade-in credit for the current instruments, reducing the overall acquisition cost while providing access to a fully supported platform with available parts and technical support. Acquiring the QuantStudio 3 at this time will help prevent interruptions to research activities, maintain reliable and consistent data generation, and ensure that NIAMS laboratories have access to a supported and dependable qPCR platform.\n\n4.1 PRODUCT FEATURES/SALIENT CHARACTERISTICS The contractor shall provide one Applied Biosystems QuantStudio 3 Real-Time PCR System or an equal system that meets all the following minimum requirements. 4.1.1. System Features/Benefits The system shall: • Utilize a platform providing 1 TB or storage space for data sharing at user discretion • be used with online scientific apps • come with desktop-based software, allowing single-plate run setup and analysis.\n\n4.1.2. Technical specifications – Instrument The instrument shall: • have a 96 well 0.1 ml plate block format and the option to run fast protocols <30 minutes • not require a field service engineer for set up by end user. Set up should be easy for end user – directly out of the box. • not require a computer for installation • use an RNase P verification plate to verify performance • not require dye calibration upon installation • have dimensions fo 27 x 50 x 40 cm and be designed to maximize horizonal and vertical bench space • be capable of analyzing 96 samples simultaneously in various formats incluing both 96-well plates, 8-tube strips and individual tubes • the 96-well block should be made of at least 3 separated Peltier elements – VeriFlex Blocks. The maximum temperature difference programmable across the block should be 10 degrees C. 5 degrees C should be the maximum difference in temperature allowed between adjacent blocks. • Support reaction volumes of 10-30 uL on 0.1mL the 96-well block • Be factory calibrated with FAM, SYBR Green 1, VIC, NED, ABY, JUN, TAMRA, and ROX dyes • Have melt or dissociation curves that take place in steps with deltaT varying between 0.015 degrees C and 3.66 degrees C • Have a maximum block ramp rate of 9.0 degrees C/sec for the 0.1 mL block • Have a block with a temperature range of 4-99.9 degrees celcius • Have a heated cover with temperature range of 50-110 degreesC 2\n\n• Have a long-lasting bright white LED source with median lifetime of at least 60,000 hours • Have a CMOS imager for data acquisition and collects data for each filter combination in less than 2 seconds • be used with 120-240 V outlets without modification or special plug requirements • Include a heated lid assembly to heat tops of sample plates and minimize reaction evaporation.\n\n4.1.3 Technical specifications – Instrument onboard computer The system shall: • Possess the capability to run in stand-alone mode, without an attached computer • Include a touchscreen interface and store protocols for quick starts with no computer needed • Have a touchscreen interface that enables viewing amplification plots and filtering them by sample, target and task • Have a touchscreen interface that facilitates uploading of protocols or downloading of run files via a USB, local network and the Connect platform • Have a touchscreen interface that allows uploading of protocols and run files directly to the Connect platform • Contain onboard storage with memory capacity of 10 GB for storing 1,000-5,000 standard absolute quantification run files, and be designed for run protection in case of power outages • Be able to be customized through the touchscreen for time zones and service/calibration notification settings • Have a touchscreen interface that supports the creation of local user accounts with PIN-protected access that can be linked to the Connect platform to online accounts on thermofisher.com • Have a touchscreen interface that allows creation and running of protocols as guests • Have a touchscreen interface that allows for editing of protocols at all stages of the reaction cycle as well as block settings, temperature settings duration, ramp rate, etc. • Have a touchscreen interface that allows a template to be loaded from a USB, local network or the Connect platform • Have a touchscreen interface that allows user to enter reagent information • Have a touchscreen interface that allows a run to be paused and during that pause for the block temperature to be set as well as for the drawer to be opened and closed • Have a touchscreen interface that allows editing of sample and target assignments • Have a touchscreen interface that allows the repeat of a previous run 3 • Have a touchscreen interface that allows users to perform dye calibrations and view results on the touchscreen • Have a touchscreen interface that allows RNase P verification runs and automatically provides pass/fail results • Have a touchscreen interface that allows a user to run a self-verification test • Have a touchscreen interface that allows the user to view the cure QC assessment after calibration and RNase P plate runs are finished • Have a touchscreen interface that allows progress monitoring.\n\n4.1.4 Performance Requirements The instrument shall: • Complete 40-cycle real-time PCR runs using fluorogenic 5’ nuclease assay and Fast chemistry in a standard 96-well plate in less than 30 minutes as well as being able to run in standard ramping mode with standard chemistry • Include an OptiFlex system that combines four coupled excitation, and emission filter sets to allow multiplexing up to four unique wavelengths • Support at least two reaction chemistries-TaqMan® Probes and SYBR Green dye • Have real-time quantitative PCR installation specifications to be able to distinguish between 5,000 and 10,000 template copies at a 99.7% confidence level.\n\n4.1.5 Software Requirements The software shall: • Allow flexible customization of run protocols • Allow the creation of secure templates that are locked with a password to limit modification of run setup • Provide run monitoring of connected instruments • Include preoptimized run protocols for applications like standard curve, relative standard curve, relative quantification of gene expression, and SNP genotyping with TaqMan® or SYBR Green chemistries • Include a copy of free software to analyze data for absolute and relative quantification, SNP detection and other assays. • Collect information on both TaqMan and SYBR assays in the same run • Have a genotyping optimization tool that uses real-time data • Provide raw fluorescence data and multicomponent data for troubleshooting • Allow conversion of protocols for the Applied Biosystems StepOnePlus and 7500 to the QuantStudio 3 system protocols • Allow batch analysis of up to 500 experiments simultaneously • Can control the instrument and analyze data from a remote computer on the same network 4 • Provide status monitoring of connected instruments and real-time plots STATEMENT OF NEED (SON) • Have the ability to send user notifications when a run is started, stopped or has an error • Allow registered users of the Connect platform to monitor any connected instrument • Allow users to run an assay plate without performing plate setup prior to beginning of run and to correct plate set up after the run • Allow export of all run results to excel and save graphs as .jpg files • Provide the ability to import a standard curve from one plate for analysis of another plate of the same instrument type • Allow for the selection of endogenous controls for gene expression experiments • Include statistical analysis tools including box-whisker plots, scatter plots and heat maps • Allow preselection of data to export and the location of the exported file • Allow for command-line functions for batch exporting of analyzed run files • Allow users to save predefined analysis settings for auto-exporting run data into format of choice • Contain online high-resolution melt application so user can specify number of clusters/variants and save defined controls and analysis setting.\n\n4.1.6 Instrument Ecosystem The instrument ecosystem shall: • Be part of a desktop ecosystem that consists of a suite of qPCR applications. Instrument data can be grouped (multi-plate) for relative quantitation, SNP genotyping, standard curve, HRM analysis, and presence/absence analysis. • Be part of the Connect platform • Be able to connect to the Connect platform for run setup download and data uploads • Allow a run to be monitored by a web browser or mobile device • Allow batch-analysis of up to 500 experiments simultaneously through an online relative quantitation module • Provide an endogenous control selection tool for gene expression experiments in both the desktop and online quantitation software • Contain statistical anaylsis tools with both the desktop and online quantitation software • Contain a genotyping optimization tool that uses real-time data to pick the best cycle number for calling genotype in both the desktop and online genotyping software • Allow the user to specify number of clusters/variants and save defined controls and analysis settings with both desktop and online software.\n\n4.1.7. Design 5 The system shall: • Have an application programming interface (API) included that allows programming routines to be developed for controlling the instrument • Be cUL, UL, CE, C-TICK, and WEEE compliant • Be developed and manufactured in a facility with quality system requirements that comply with ISO 13485 standards and ISO 9001 standards 4.1.8 Gene expression profiling • Users shall be able to select from more than 61,000 predesigned human, mouse and rat Applied BiosystemsTMTaqMan® Assays.\n\n4.1.9 Able to accept the trade-in of Model STEPONEPLUS. Serial number 272008444 4.1.10 Must be compatible with protocols from Applied Biosystems StepOnePlus Real Time PCR (qPCR) allowing for consistency in experimental set-up 4.2 DELIVERY / INSTALLATION The contractor shall deliver and install the equipment within thirty (30) calendar days after receipt of award.","html":"<p>Requirements:</p>\n\n<p>To ensure continuity of research, NIAMS proposes the acquisition of an Applied Biosystems QuantStudio 3 Real-Time PCR System. qPCR is a core technology used for nucleic acid amplification, quantification, and analysis and supports a wide range of research applications, including gene expression studies, pathogen detection, transcript quantification, and validation of experimental results. The QuantStudio 3 is the closest replacement to the current StepOnePlus systems, allowing researchers to maintain established workflows and consistency in experimental design and data interpretation. The QuantStudio 3 offers several operational advantages, including user-friendly software, compatibility with both Mac and PC platforms, touchscreen operation, and the ability to function as a standalone instrument or in conjunction with a computer. Its thermal block design is similar to the existing systems, minimizing the learning curve for users and supporting a broad range of genomic applications. In addition, the manufacturer offers trade-in credit for the current instruments, reducing the overall acquisition cost while providing access to a fully supported platform with available parts and technical support. Acquiring the QuantStudio 3 at this time will help prevent interruptions to research activities, maintain reliable and consistent data generation, and ensure that NIAMS laboratories have access to a supported and dependable qPCR platform.</p>\n\n<p>4.1 PRODUCT FEATURES/SALIENT CHARACTERISTICS The contractor shall provide one Applied Biosystems QuantStudio 3 Real-Time PCR System or an equal system that meets all the following minimum requirements. 4.1.1. System Features/Benefits The system shall: &bull; Utilize a platform providing 1 TB or storage space for data sharing at user discretion &bull; be used with online scientific apps &bull; come with desktop-based software, allowing single-plate run setup and analysis.</p>\n\n<p>4.1.2. Technical specifications &ndash; Instrument The instrument shall: &bull; have a 96 well 0.1 ml plate block format and the option to run fast protocols &lt;30 minutes &bull; not require a field service engineer for set up by end user. Set up should be easy for end user &ndash; directly out of the box. &bull; not require a computer for installation &bull; use an RNase P verification plate to verify performance &bull; not require dye calibration upon installation &bull; have dimensions fo 27 x 50 x 40 cm and be designed to maximize horizonal and vertical bench space &bull; be capable of analyzing 96 samples simultaneously in various formats incluing both 96-well plates, 8-tube strips and individual tubes &bull; the 96-well block should be made of at least 3 separated Peltier elements &ndash; VeriFlex Blocks. The maximum temperature difference programmable across the block should be 10 degrees C. 5 degrees C should be the maximum difference in temperature allowed between adjacent blocks. &bull; Support reaction volumes of 10-30 uL on 0.1mL the 96-well block &bull; Be factory calibrated with FAM, SYBR Green 1, VIC, NED, ABY, JUN, TAMRA, and ROX dyes &bull; Have melt or dissociation curves that take place in steps with deltaT varying between 0.015 degrees C and 3.66 degrees C &bull; Have a maximum block ramp rate of 9.0 degrees C/sec for the 0.1 mL block &bull; Have a block with a temperature range of 4-99.9 degrees celcius &bull; Have a heated cover with temperature range of 50-110 degreesC 2</p>\n\n<p>&bull; Have a long-lasting bright white LED source with median lifetime of at least 60,000 hours &bull; Have a CMOS imager for data acquisition and collects data for each filter combination in less than 2 seconds &bull; be used with 120-240 V outlets without modification or special plug requirements &bull; Include a heated lid assembly to heat tops of sample plates and minimize reaction evaporation.</p>\n\n<p>&nbsp;4.1.3 Technical specifications &ndash; Instrument onboard computer The system shall: &bull; Possess the capability to run in stand-alone mode, without an attached computer &bull; Include a touchscreen interface and store protocols for quick starts with no computer needed &bull; Have a touchscreen interface that enables viewing amplification plots and filtering them by sample, target and task &bull; Have a touchscreen interface that facilitates uploading of protocols or downloading of run files via a USB, local network and the Connect platform &bull; Have a touchscreen interface that allows uploading of protocols and run files directly to the Connect platform &bull; Contain onboard storage with memory capacity of 10 GB for storing 1,000-5,000 standard absolute quantification run files, and be designed for run protection in case of power outages &bull; Be able to be customized through the touchscreen for time zones and service/calibration notification settings &bull; Have a touchscreen interface that supports the creation of local user accounts with PIN-protected access that can be linked to the Connect platform to online accounts on thermofisher.com &bull; Have a touchscreen interface that allows creation and running of protocols as guests &bull; Have a touchscreen interface that allows for editing of protocols at all stages of the reaction cycle as well as block settings, temperature settings duration, ramp rate, etc. &bull; Have a touchscreen interface that allows a template to be loaded from a USB, local network or the Connect platform &bull; Have a touchscreen interface that allows user to enter reagent information &bull; Have a touchscreen interface that allows a run to be paused and during that pause for the block temperature to be set as well as for the drawer to be opened and closed &bull; Have a touchscreen interface that allows editing of sample and target assignments &bull; Have a touchscreen interface that allows the repeat of a previous run 3 &bull; Have a touchscreen interface that allows users to perform dye calibrations and view results on the touchscreen &bull; Have a touchscreen interface that allows RNase P verification runs and automatically provides pass/fail results &bull; Have a touchscreen interface that allows a user to run a self-verification test &bull; Have a touchscreen interface that allows the user to view the cure QC assessment after calibration and RNase P plate runs are finished &bull; Have a touchscreen interface that allows progress monitoring.</p>\n\n<p>&nbsp;4.1.4 Performance Requirements The instrument shall: &bull; Complete 40-cycle real-time PCR runs using fluorogenic 5&rsquo; nuclease assay and Fast chemistry in a standard 96-well plate in less than 30 minutes as well as being able to run in standard ramping mode with standard chemistry &bull; Include an OptiFlex system that combines four coupled excitation, and emission filter sets to allow multiplexing up to four unique wavelengths &bull; Support at least two reaction chemistries-TaqMan&reg; Probes and SYBR Green dye &bull; Have real-time quantitative PCR installation specifications to be able to distinguish between 5,000 and 10,000 template copies at a 99.7% confidence level.</p>\n\n<p>&nbsp;4.1.5 Software Requirements The software shall: &bull; Allow flexible customization of run protocols &bull; Allow the creation of secure templates that are locked with a password to limit modification of run setup &bull; Provide run monitoring of connected instruments &bull; Include preoptimized run protocols for applications like standard curve, relative standard curve, relative quantification of gene expression, and SNP genotyping with TaqMan&reg; or SYBR Green chemistries &bull; Include a copy of free software to analyze data for absolute and relative quantification, SNP detection and other assays. &bull; Collect information on both TaqMan and SYBR assays in the same run &bull; Have a genotyping optimization tool that uses real-time data &bull; Provide raw fluorescence data and multicomponent data for troubleshooting &bull; Allow conversion of protocols for the Applied Biosystems StepOnePlus and 7500 to the QuantStudio 3 system protocols &bull; Allow batch analysis of up to 500 experiments simultaneously &bull; Can control the instrument and analyze data from a remote computer on the same network 4 &bull; Provide status monitoring of connected instruments and real-time plots STATEMENT OF NEED (SON) &bull; Have the ability to send user notifications when a run is started, stopped or has an error &bull; Allow registered users of the Connect platform to monitor any connected instrument &bull; Allow users to run an assay plate without performing plate setup prior to beginning of run and to correct plate set up after the run &bull; Allow export of all run results to excel and save graphs as .jpg files &bull; Provide the ability to import a standard curve from one plate for analysis of another plate of the same instrument type &bull; Allow for the selection of endogenous controls for gene expression experiments &bull; Include statistical analysis tools including box-whisker plots, scatter plots and heat maps &bull; Allow preselection of data to export and the location of the exported file &bull; Allow for command-line functions for batch exporting of analyzed run files &bull; Allow users to save predefined analysis settings for auto-exporting run data into format of choice &bull; Contain online high-resolution melt application so user can specify number of clusters/variants and save defined controls and analysis setting.</p>\n\n<p>&nbsp;4.1.6 Instrument Ecosystem The instrument ecosystem shall: &bull; Be part of a desktop ecosystem that consists of a suite of qPCR applications. Instrument data can be grouped (multi-plate) for relative quantitation, SNP genotyping, standard curve, HRM analysis, and presence/absence analysis. &bull; Be part of the Connect platform &bull; Be able to connect to the Connect platform for run setup download and data uploads &bull; Allow a run to be monitored by a web browser or mobile device &bull; Allow batch-analysis of up to 500 experiments simultaneously through an online relative quantitation module &bull; Provide an endogenous control selection tool for gene expression experiments in both the desktop and online quantitation software &bull; Contain statistical anaylsis tools with both the desktop and online quantitation software &bull; Contain a genotyping optimization tool that uses real-time data to pick the best cycle number for calling genotype in both the desktop and online genotyping software &bull; Allow the user to specify number of clusters/variants and save defined controls and analysis settings with both desktop and online software.</p>\n\n<p>&nbsp;4.1.7. &nbsp;Design 5 The system shall: &bull; Have an application programming interface (API) included that allows programming routines to be developed for controlling the instrument &bull; Be cUL, UL, CE, C-TICK, and WEEE compliant &bull; Be developed and manufactured in a facility with quality system requirements that comply with ISO 13485 standards and ISO 9001 standards 4.1.8 Gene expression profiling &bull; Users shall be able to select from more than 61,000 predesigned human, mouse and rat Applied BiosystemsTMTaqMan&reg; Assays.</p>\n\n<p>&nbsp;4.1.9 Able to accept the trade-in of Model STEPONEPLUS. Serial number 272008444 4.1.10 Must be compatible with protocols from Applied Biosystems StepOnePlus Real Time PCR (qPCR) allowing for consistency in experimental set-up 4.2 DELIVERY / INSTALLATION The contractor shall deliver and install the equipment within thirty (30) calendar days after receipt of award.</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"John Burton","role":"primary","email":"burtonjo@mail.nih.gov"}],"place_of_performance":{"zip":"20892","city":{"code":"7125","name":"Bethesda"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"5e8b61c585064d978a2e3b5234727ebd","name":"Requirements rev8.docx","kind":"file","mime_type":".docx","size_bytes":18540,"posted_at":"2026-07-09T14:50:48.638Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5e8b61c585064d978a2e3b5234727ebd/download","mirrored":false}],"awards":[],"related":[{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"NOIOD27000713","latest_notice_id":"a3fe6af21d9943e1a009483e9b326b40","title":"Notice of Intent to Sole Source – Werfen USA LLC – ACL TOP 750 Analyzers kits and reagents","solicitation_number":"NOI-OD-27-000713","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"J066","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98026Q00083","latest_notice_id":"32e71d66f9cf4440835ca571c1834aac","title":"ChemiDoc Go Imaging System","solicitation_number":"75N98026Q00083","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-28T14:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"state":"CA","county":"06013","county_name":"Contra Costa County","city":"0633308","city_name":"Hercules","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}