{"canonical":"https://sealedbidder.com/opportunities/75n98026q00400","key":"75N98026Q00400","url":"https://sealedbidder.com/opportunities/75n98026q00400","title":"​Consol Tower Sterilizer​","solicitation_number":"75N98026Q00400","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-01T13:00:00Z","first_posted":"2026-05-19","last_posted":"2026-05-19","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"NATIONAL INSTITUTES OF HEALTH","office":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":"8AN","place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"14e258d101ee422ea087dae9cbd6e9cf","title":"​Consol Tower Sterilizer​","solicitation_number":"75N98026Q00400","notice_type":"k","base_type":"k","posted":"2026-05-19","posted_at":"2026-05-19T20:23:30.359Z","due_at":"2026-06-01T13:00:00Z","due_date":"2026-06-01","cancelled":false,"archived":true,"archive_date":"2026-06-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/14e258d101ee422ea087dae9cbd6e9cf/view","enriched":true,"history":[{"index":3,"title":"​Consol Tower Sterilizer​","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T20:23:30.359Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"14e258d101ee422ea087dae9cbd6e9cf","solicitation_number":"75N98026Q00400"}]}],"latest_notice_id":"14e258d101ee422ea087dae9cbd6e9cf","first_type":"k","notices":[{"dates":{"posted":"2026-05-19","posted_at":"2026-05-19T20:23:30.359Z","created_at":"2026-05-19T19:32:52.190Z","modified_at":"2026-06-02T04:00:07.158Z","response_deadline":{"raw":"2026-06-01T09:00:00-04:00","utc":"2026-06-01T13:00:00Z","date":"2026-06-01","time":"09:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/14e258d101ee422ea087dae9cbd6e9cf/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"​Consol Tower Sterilizer​","agency":{"office":{"code":"75N980","name":"NATIONAL INSTITUTES OF HEALTH OLAO"},"subtier":{"code":"7529","name":"NATIONAL INSTITUTES OF HEALTH"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"organization_id":"100189057","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-01","archive_type":"auto_custom"},"history":[{"index":3,"title":"​Consol Tower Sterilizer​","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-19T20:23:30.359Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"14e258d101ee422ea087dae9cbd6e9cf","solicitation_number":"75N98026Q00400"}],"contacts":[{"name":"John Burton","role":"primary","email":"burtonjo@mail.nih.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"14e258d101ee422ea087dae9cbd6e9cf","set_aside":{"code":"8AN","label":"8(a) Sole Source (FAR 19.8)"},"lineage_id":"14e258d101ee422ea087dae9cbd6e9cf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-03T07:27:37.458796208Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"51e1522cf23567fbc7992b029eef08e35e028f7374fd8be9aaa336de284f29a0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-03T07:27:37.458796208Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>An autoclave is an essential, reliable, and cost-effective scientific instrument that uses high-pressure steam to sterilize equipment, media, and biohazardous waste. It ensures the elimination of microorganisms, prevents contamination of microbiological cultures and laboratory tools, and safely sterilizes infectious waste prior to disposal.&nbsp;</p>\n\n<p>The following product features/characteristics are required for this requirement.</p>\n\n<p>Equipment Specifications:</p>\n\n<p>&middot; Dual chamber tower sterilizer with approximate chamber dimensions of 20&quot; &times; 20&quot; &times; 38&quot;</p>\n\n<p>&middot; 316L stainless steel chamber with carbon steel jacket and passivated finish</p>\n\n<p>&middot; Double chamber configuration with stainless steel recessed panels and cabinet-mounted design</p>\n\n<p>&middot; Hinged, fully opening manual door with right-side hinge</p>\n\n<p>&middot; Chamber configuration includes:</p>\n\n<p>- Top chamber with two (2) standard shelves</p>\n\n<p>- Bottom chamber with two (2) extendable shelves</p>\n\n<p>&middot; Integrated control system with:</p>\n\n<p>- 7-inch color touchscreen interface</p>\n\n<p>- Minimum of 50 programmable sterilization cycles</p>\n\n<p>- Password protection supporting multiple users</p>\n\n<p>- Lockable cycle parameters</p>\n\n<p>&middot; Data and monitoring capabilities including:</p>\n\n<p>- Thermal printer for cycle documentation</p>\n\n<p>- USB dataport for data export</p>\n\n<p>&middot; High-performance sterilization system including:</p>\n\n<p>- High-vacuum system with water ejector (minimum 45 psi required)</p>\n\n<p>- Automatic jacket blowdown for liquid cycles</p>\n\n<p>- Compatibility with house steam supply</p>\n\n<p>&middot; Water and energy efficiency features including:</p>\n\n<p>- Water conservation and monitoring system</p>\n\n<p>- Automatic idle shut-off and energy management functionality</p>\n\n<p>&middot; Safety and compliance features including:</p>\n\n<p>- Emergency stop button</p>\n\n<p>- ASME U-1 code stamped pressure vessel</p>\n\n<p>- UL and cUL certification</p>\n\n<p>- Thermocouple port for validation</p>\n\n<p>&middot; Constructed with brass, bronze, and copper piping</p>\n\n<p>&middot; Includes starter kit with cleaning supplies, autoclave gloves, printer supplies, and manuals.</p>\n\n<p></p>","text":"An autoclave is an essential, reliable, and cost-effective scientific instrument that uses high-pressure steam to sterilize equipment, media, and biohazardous waste. It ensures the elimination of microorganisms, prevents contamination of microbiological cultures and laboratory tools, and safely sterilizes infectious waste prior to disposal.\n\nThe following product features/characteristics are required for this requirement.\n\nEquipment Specifications:\n\n· Dual chamber tower sterilizer with approximate chamber dimensions of 20\" × 20\" × 38\"\n\n· 316L stainless steel chamber with carbon steel jacket and passivated finish\n\n· Double chamber configuration with stainless steel recessed panels and cabinet-mounted design\n\n· Hinged, fully opening manual door with right-side hinge\n\n· Chamber configuration includes:\n\n- Top chamber with two (2) standard shelves\n\n- Bottom chamber with two (2) extendable shelves\n\n· Integrated control system with:\n\n- 7-inch color touchscreen interface\n\n- Minimum of 50 programmable sterilization cycles\n\n- Password protection supporting multiple users\n\n- Lockable cycle parameters\n\n· Data and monitoring capabilities including:\n\n- Thermal printer for cycle documentation\n\n- USB dataport for data export\n\n· High-performance sterilization system including:\n\n- High-vacuum system with water ejector (minimum 45 psi required)\n\n- Automatic jacket blowdown for liquid cycles\n\n- Compatibility with house steam supply\n\n· Water and energy efficiency features including:\n\n- Water conservation and monitoring system\n\n- Automatic idle shut-off and energy management functionality\n\n· Safety and compliance features including:\n\n- Emergency stop button\n\n- ASME U-1 code stamped pressure vessel\n\n- UL and cUL certification\n\n- Thermocouple port for validation\n\n· Constructed with brass, bronze, and copper piping\n\n· Includes starter kit with cleaning supplies, autoclave gloves, printer supplies, and manuals.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"75N98026Q00400","place_of_performance":{"zip":"20892","state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"}],"due_at":"2026-06-01T13:00:00Z","due_date":"2026-06-01","closes_at":"2026-06-01T13:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","state":"MD","county":"24031","county_name":"Montgomery County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-03T08:11:27.711804Z","principal_notice_id":"14e258d101ee422ea087dae9cbd6e9cf","description":{"text":"An autoclave is an essential, reliable, and cost-effective scientific instrument that uses high-pressure steam to sterilize equipment, media, and biohazardous waste. It ensures the elimination of microorganisms, prevents contamination of microbiological cultures and laboratory tools, and safely sterilizes infectious waste prior to disposal.\n\nThe following product features/characteristics are required for this requirement.\n\nEquipment Specifications:\n\n· Dual chamber tower sterilizer with approximate chamber dimensions of 20\" × 20\" × 38\"\n\n· 316L stainless steel chamber with carbon steel jacket and passivated finish\n\n· Double chamber configuration with stainless steel recessed panels and cabinet-mounted design\n\n· Hinged, fully opening manual door with right-side hinge\n\n· Chamber configuration includes:\n\n- Top chamber with two (2) standard shelves\n\n- Bottom chamber with two (2) extendable shelves\n\n· Integrated control system with:\n\n- 7-inch color touchscreen interface\n\n- Minimum of 50 programmable sterilization cycles\n\n- Password protection supporting multiple users\n\n- Lockable cycle parameters\n\n· Data and monitoring capabilities including:\n\n- Thermal printer for cycle documentation\n\n- USB dataport for data export\n\n· High-performance sterilization system including:\n\n- High-vacuum system with water ejector (minimum 45 psi required)\n\n- Automatic jacket blowdown for liquid cycles\n\n- Compatibility with house steam supply\n\n· Water and energy efficiency features including:\n\n- Water conservation and monitoring system\n\n- Automatic idle shut-off and energy management functionality\n\n· Safety and compliance features including:\n\n- Emergency stop button\n\n- ASME U-1 code stamped pressure vessel\n\n- UL and cUL certification\n\n- Thermocouple port for validation\n\n· Constructed with brass, bronze, and copper piping\n\n· Includes starter kit with cleaning supplies, autoclave gloves, printer supplies, and manuals.","html":"<p>An autoclave is an essential, reliable, and cost-effective scientific instrument that uses high-pressure steam to sterilize equipment, media, and biohazardous waste. It ensures the elimination of microorganisms, prevents contamination of microbiological cultures and laboratory tools, and safely sterilizes infectious waste prior to disposal.&nbsp;</p>\n\n<p>The following product features/characteristics are required for this requirement.</p>\n\n<p>Equipment Specifications:</p>\n\n<p>&middot; Dual chamber tower sterilizer with approximate chamber dimensions of 20&quot; &times; 20&quot; &times; 38&quot;</p>\n\n<p>&middot; 316L stainless steel chamber with carbon steel jacket and passivated finish</p>\n\n<p>&middot; Double chamber configuration with stainless steel recessed panels and cabinet-mounted design</p>\n\n<p>&middot; Hinged, fully opening manual door with right-side hinge</p>\n\n<p>&middot; Chamber configuration includes:</p>\n\n<p>- Top chamber with two (2) standard shelves</p>\n\n<p>- Bottom chamber with two (2) extendable shelves</p>\n\n<p>&middot; Integrated control system with:</p>\n\n<p>- 7-inch color touchscreen interface</p>\n\n<p>- Minimum of 50 programmable sterilization cycles</p>\n\n<p>- Password protection supporting multiple users</p>\n\n<p>- Lockable cycle parameters</p>\n\n<p>&middot; Data and monitoring capabilities including:</p>\n\n<p>- Thermal printer for cycle documentation</p>\n\n<p>- USB dataport for data export</p>\n\n<p>&middot; High-performance sterilization system including:</p>\n\n<p>- High-vacuum system with water ejector (minimum 45 psi required)</p>\n\n<p>- Automatic jacket blowdown for liquid cycles</p>\n\n<p>- Compatibility with house steam supply</p>\n\n<p>&middot; Water and energy efficiency features including:</p>\n\n<p>- Water conservation and monitoring system</p>\n\n<p>- Automatic idle shut-off and energy management functionality</p>\n\n<p>&middot; Safety and compliance features including:</p>\n\n<p>- Emergency stop button</p>\n\n<p>- ASME U-1 code stamped pressure vessel</p>\n\n<p>- UL and cUL certification</p>\n\n<p>- Thermocouple port for validation</p>\n\n<p>&middot; Constructed with brass, bronze, and copper piping</p>\n\n<p>&middot; Includes starter kit with cleaning supplies, autoclave gloves, printer supplies, and manuals.</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"John Burton","role":"primary","email":"burtonjo@mail.nih.gov"}],"place_of_performance":{"zip":"20892","state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20892","city":"BETHESDA","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"502d01ce3c984eaa99b8cf9eb9d5b90e","name":"SON for Consol Tower Sterilizer.pdf","kind":"file","mime_type":".pdf","size_bytes":208137,"posted_at":"2026-05-19T20:23:30.359Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/502d01ce3c984eaa99b8cf9eb9d5b90e/download","mirrored":false}],"awards":[],"related":[{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"NOIOD27000713","latest_notice_id":"a3fe6af21d9943e1a009483e9b326b40","title":"Notice of Intent to Sole Source – Werfen USA LLC – ACL TOP 750 Analyzers kits and reagents","solicitation_number":"NOI-OD-27-000713","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"J066","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98026Q00083","latest_notice_id":"32e71d66f9cf4440835ca571c1834aac","title":"ChemiDoc Go Imaging System","solicitation_number":"75N98026Q00083","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-28T14:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334516","psc":"6640","set_aside":null,"state":"CA","county":"06013","county_name":"Contra Costa County","city":"0633308","city_name":"Hercules","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}