Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,710 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Combined synopsis and solicitation

Acquisition of Two Triple Multitron Standard Incubation Shakers with Top Cooling

75N98026Q00394

National Institutes of Health, National Institutes of Health Olao. Analytical Laboratory Instrument Manufacturing.

Response deadline

June 1, 2026 at 9:00 AM EDT

Closed 178 days ago. Posted May 19, 2026. Scheduled to archive June 1, 2026.

Get the next one like this from National Institutes of Health by email, the day it is posted.Find my opportunities

This one closed in 2026

55 like it are open now in analytical laboratory instrument manufacturing

All 55 open in analytical laboratory instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
Time to respond
Bidders had 13 days from the day the solicitation was posted, May 19, 2026, to the deadline.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

NIDDK owns two Triple Multitron Standard Incubation Shakers with Top Cooling.  Each Triple Multitron consists of three stacked incubation shakers within a small footprint.  Each of the three incubation shakers within a Triple Multitron is capable of independent temperature and speed control.  These features maximize the total amount of cultures that can be grown at the same time, as well as, maximizing the possible growth conditions.  Currently, none of the incubation shakers within the two Multitrons cool properly; and they do not reliably maintain a constant temperature.  This procurement is to buy two new Triple Multitron Standard Incubation Shakers with Top Cooling.    

The following product features/characteristics are required for this requirement:  

  • Each triple incubation shaker unit must consist of three stacked incubation shakers in a small footprint to fit within the available space in the laboratory (not wider than 43 inches and not deeper than 35 inches) 

  • Each incubation shaker per triple stacked unit must be capable of independently reaching a temperature that is 15 degrees C below ambient temperature to 65 degrees C to accommodate a large range of temperatures to grow cultures. 

  • Each incubation shaker per triple stacked unit must have a capacity of 6 x 5L Erlenmeyer flasks (total of 18 flasks per triple-stacked unit) to maximize the volume of cultures grown within the small footprint. 

  • The temperature and speed of each incubation shaker per triple stacked unit must be able to be set independently of the others to maximize the variety of growth conditions within the small footprint.   

  • Each incubation shaker must have a single bearing eccentric drive to move the main shaft for quiet operation and very little vibration. 

  • Each incubation shaker must have the entire shaking mechanism enclosed to ensure temperature uniformity. 

  • Each incubation shaker must have four blowers to eliminate dead spots within the cabinet to maintain temperature uniformity.   

  • The height of the triple stacked unit must allow it to fit through standard laboratory doors. 

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. May 19, 2026

    Combined synopsis and solicitation

    Due June 1, 2026 at 9:00 AM EDT. SAM.gov, notice 9a0f474e08b44638ade3a36d8ed2138f

    1 revision on SAM
    • May 19, 2026: publish, combined synopsis and solicitation

Points of contact