{"canonical":"https://sealedbidder.com/opportunities/75f40126q00375","key":"75F40126Q00375","url":"https://sealedbidder.com/opportunities/75f40126q00375","title":"Sodium Iodide Detector for Thyroid Counting","solicitation_number":"75F40126Q00375","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-31T18:00:00Z","first_posted":"2026-08-25","last_posted":"2026-08-25","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"FOOD AND DRUG ADMINISTRATION","office":"FDA Office of Acquisitions and Grants Services","naics":"334516","psc":"6630","set_aside":"SBA","place_state":"MA","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"25017","place_county_name":"Middlesex County","place_city":"2580545","place_city_name":"Winchester","winner":null,"award_amount":null,"publications":[{"notice_id":"d3c5244a4a9a4cce939b61b0fb4802ef","title":"Sodium Iodide Detector for Thyroid Counting","solicitation_number":"75F40126Q00375","notice_type":"k","base_type":"k","posted":"2026-08-25","posted_at":"2026-08-25T13:58:34.099Z","due_at":"2026-08-31T18:00:00Z","due_date":"2026-08-31","cancelled":false,"archived":true,"archive_date":"2026-09-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d3c5244a4a9a4cce939b61b0fb4802ef/view","enriched":true,"history":[{"index":3,"title":"Sodium Iodide Detector for Thyroid Counting","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-25T13:58:34.099Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d3c5244a4a9a4cce939b61b0fb4802ef","solicitation_number":"75F40126Q00375"}]}],"latest_notice_id":"d3c5244a4a9a4cce939b61b0fb4802ef","first_type":"k","notices":[{"dates":{"posted":"2026-08-25","posted_at":"2026-08-25T13:58:34.099Z","created_at":"2026-08-25T13:38:05.517Z","modified_at":"2026-09-15T05:07:31.448Z","response_deadline":{"raw":"2026-08-31T14:00:00-04:00","utc":"2026-08-31T18:00:00Z","date":"2026-08-31","time":"14:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d3c5244a4a9a4cce939b61b0fb4802ef/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Sodium Iodide Detector for Thyroid Counting","agency":{"office":{"code":"75FDA1","name":"FDA Office of Acquisitions and Grants Services"},"subtier":{"code":"7524","name":"FOOD AND DRUG ADMINISTRATION"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20857","city":"Rockville","state":"MD","country":"USA"},"organization_id":"500035507","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-15","archive_type":"auto15"},"history":[{"index":3,"title":"Sodium Iodide Detector for Thyroid Counting","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-25T13:58:34.099Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"d3c5244a4a9a4cce939b61b0fb4802ef","solicitation_number":"75F40126Q00375"}],"contacts":[{"name":"Lilibeth Deato","role":"primary","email":"lilibeth.deato@fda.hhs.gov","phone":"3017960349"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"d3c5244a4a9a4cce939b61b0fb4802ef","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"d3c5244a4a9a4cce939b61b0fb4802ef","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T10:20:54.095303865Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"1571ce30698fe7b740fc98b2cfaecbac-30\"","fetched_at":"2026-09-16T00:55:28.845070Z","row_sha256":"ae0f15cbdd5700bbbec2449355a2c4271b13cfa14ee142503e07da115398a44e","last_modified":"2026-09-15T03:30:54Z"},"updated_at":"2026-09-24T10:20:54.095303865Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"<p>This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested, and a written solicitation will not be issued separately.</p>\n\n<p><strong>Solicitation No.:</strong> <strong>75F40126Q00375&nbsp;</strong><br />\n<strong>Contracting Activity:</strong> Food and Drug Administration (FDA)<br />\n<strong>Office/Center:</strong> Office of the Commissioner (OC)<br />\n<strong>Acquisition Type:</strong> Commercial Product<br />\n<strong>Solicitation Type:</strong> Request for Quotation (RFQ)<br />\n<strong>Contract Type:</strong> Firm-Fixed-Price Purchase Order<br />\n<strong>Estimated Value:</strong> $20,000<br />\n<strong>Required Delivery:</strong> September 15, 2026</p>\n\n<p><u><strong>DELIVERABLE:</strong></u></p>\n\n<p>1. 3X3 LED Temperature stabilized Sodium Iodide Probe compatible with Mirion Osprey Multi Channel Analyzer</p>\n\n<p>Delivery Date: 9/15/2026</p>\n\n<p></p>\n\n<p>2. Digital Tube Based Multichannel Analyzer with USB and Ethernet output</p>\n\n<p>Delivery Date: 09/15/2026</p>\n\n<p><u><strong>Salient Characteristics</strong></u></p>\n\n<p>The equipment offered shall meet or exceed all requirements listed below.</p>\n\n<p><strong><u>Detector Characteristics</u></strong></p>\n\n<ul>\n\t<li>3&rdquo;X 3&rdquo; NaI(Tl) LED Stabilized Scintillation Detector</li>\n\t<li>Energy Range 30 keV to 3 MeV</li>\n\t<li>Resolution &gt;7%</li>\n\t<li>Available with generic efficiency characterization</li>\n\t<li>OPERATING HUMIDITY &ndash; 85% non-condensing</li>\n\t<li>OPERATING TEMPERATURE &ndash; -20 to +50 &deg;C (-4 to 122 &deg;F).</li>\n\t<li>Must be compatible and seamlessly compatible with Apex InVivo Software and Mirion Osprey Multichannel Digital Analyzer</li>\n\t<li>Diameter less than 3.5&rdquo;</li>\n\t<li>Weight &lt; 6 lbs</li>\n</ul>\n\n<p></p>\n\n<p><strong><u>Multi-Channel Digital Analyzer Characteristics</u></strong></p>\n\n<ul>\n\t<li>Includes HVPS, Preamplifier and Digital MCA</li>\n\t<li>Gain Coarse Gain: x1, x2, x4, x8 software programmable</li>\n\t<li>Fine Gain: x1 &ndash; x5 software programmable</li>\n\t<li>Total Gain: Product of Fine Gain and Coarse Gain, x1 &ndash; x40</li>\n\t<li>ADC: ADC 14-Bit 20 MHz Sampling</li>\n\t<li>ULD/LLD ULD: 0% to 100% of Full Scale software programmable</li>\n\t<li>LLD: 0% to 100% of Full Scale software programmable</li>\n\t<li>Detector Voltage: HVPS 0 to +1300 V dc: 100 V/s ramping on power up and down</li>\n\t<li>Shaping DSP Based Trapezoidal shaping filter operating at 80 MHz</li>\n\t<li>Rise Time: 0.2 &mu;s &ndash; 5 &mu;s in 200 ns steps. Default: 1 &mu;s for NaI probe</li>\n\t<li>Flat Top: 0 to 3 &mu;s in 100 ns steps. Default: 1 &mu;s for NaI probe</li>\n\t<li>Digital Spectrum Stabilization</li>\n\t<li>Automatic Baseline Restore</li>\n\t<li>Automatic Fast Discriminator threshold</li>\n\t<li>Seamlessly compatible with Apex InVivo Software</li>\n\t<li>USB 2.0 and Ethernet 10/100BaseTX Output</li>\n\t<li>14 pin and 8 pin PMT socket compatible</li>\n\t<li>Diameter less than 3.5&rdquo;</li>\n\t<li>Weight &lt; 6 lbs</li>\n\t<li>ACQUISITION MODES\n\t<ul>\n\t\t<li>PHA PHA Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each</li>\n\t\t<li>Preset: ROI Counts (Integral), Real or Live Time timers</li>\n\t\t<li>Real and Live Time Resolution: 0.01 s</li>\n\t\t<li>Preset Time: 0 to &gt;4 x 107 s</li>\n\t\t<li>Control: Internal or External Start/Stop control</li>\n\t\t<li>LTC accuracy: 5% (3% typical) up to 50 kcps</li>\n\t</ul>\n\t</li>\n\t<li>MCS\n\t<ul>\n\t\t<li>MCS Dwell range: 1 &mu;s to 999 seconds in 1 &mu;s steps</li>\n\t\t<li>Sweep range: 1 to 232 -1</li>\n\t\t<li>Preset Sweep Counter: 0 to 232 -1 Sweeps (0 implies &quot;Forever&quot;)</li>\n\t\t<li>MCS input selection: PHA ROI, external TTL or Fast Discriminator</li>\n\t\t<li>Dwell selection: internal or external</li>\n\t\t<li>MCS Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each</li>\n\t</ul>\n\t</li>\n\t<li>8192 Channels Configurable as two groups of 2048, 1024, 512 or 256 channels for PHA and MCS with 32 bits per channel</li>\n\t<li>Integral Non-linearity: &plusmn;0.025% of full scale over the top 99% of the selected range</li>\n\t<li>Differential Non-linearity: &plusmn;1% over the top 99% of the range including the effects from integral non-linearity</li>\n\t<li>Gain Drift: &lt;75 ppm/&deg;C after 15 minutes of operation</li>\n\t<li>Incoming Count Rate (ICR): &gt;250 K cps ICR if not limited by probe/detector</li>\n\t<li>Short Circuit Protection</li>\n\t<li>High Voltage Power Supply\n\t<ul>\n\t\t<li>OUTPUT: 0-1300 V at 50 &mu;A max</li>\n\t\t<li>RIPPLE: 1 mV &mdash; ACCURACY: 3% Full Scale</li>\n\t\t<li>SETTING RESOLUTION: 14-bit (1/16 384)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p></p>\n\n<p><strong>WARRANTY AND SUPPORT</strong></p>\n\n<p>The Contractor shall provide a minimum <strong>12-calendar-month warranty</strong> covering all parts and labor.</p>\n\n<p>The warranty period shall begin on the date of formal Government acceptance.</p>\n\n<p>Warranty service shall include repair or replacement of defective components necessary to maintain operation of the delivered system.</p>\n\n<p></p>\n\n<p>Review the attached document for complete description of the requirement.</p>\n\n<p></p>","text":"This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested, and a written solicitation will not be issued separately.\n\nSolicitation No.: 75F40126Q00375\n\nContracting Activity: Food and Drug Administration (FDA)\n\nOffice/Center: Office of the Commissioner (OC)\n\nAcquisition Type: Commercial Product\n\nSolicitation Type: Request for Quotation (RFQ)\n\nContract Type: Firm-Fixed-Price Purchase Order\n\nEstimated Value: $20,000\n\nRequired Delivery: September 15, 2026\n\nDELIVERABLE:\n\n1. 3X3 LED Temperature stabilized Sodium Iodide Probe compatible with Mirion Osprey Multi Channel Analyzer\n\nDelivery Date: 9/15/2026\n\n2. Digital Tube Based Multichannel Analyzer with USB and Ethernet output\n\nDelivery Date: 09/15/2026\n\nSalient Characteristics\n\nThe equipment offered shall meet or exceed all requirements listed below.\n\nDetector Characteristics\n\n• 3”X 3” NaI(Tl) LED Stabilized Scintillation Detector\n\n• Energy Range 30 keV to 3 MeV\n\n• Resolution >7%\n\n• Available with generic efficiency characterization\n\n• OPERATING HUMIDITY – 85% non-condensing\n\n• OPERATING TEMPERATURE – -20 to +50 °C (-4 to 122 °F).\n\n• Must be compatible and seamlessly compatible with Apex InVivo Software and Mirion Osprey Multichannel Digital Analyzer\n\n• Diameter less than 3.5”\n\n• Weight < 6 lbs\n\nMulti-Channel Digital Analyzer Characteristics\n\n• Includes HVPS, Preamplifier and Digital MCA\n\n• Gain Coarse Gain: x1, x2, x4, x8 software programmable\n\n• Fine Gain: x1 – x5 software programmable\n\n• Total Gain: Product of Fine Gain and Coarse Gain, x1 – x40\n\n• ADC: ADC 14-Bit 20 MHz Sampling\n\n• ULD/LLD ULD: 0% to 100% of Full Scale software programmable\n\n• LLD: 0% to 100% of Full Scale software programmable\n\n• Detector Voltage: HVPS 0 to +1300 V dc: 100 V/s ramping on power up and down\n\n• Shaping DSP Based Trapezoidal shaping filter operating at 80 MHz\n\n• Rise Time: 0.2 μs – 5 μs in 200 ns steps. Default: 1 μs for NaI probe\n\n• Flat Top: 0 to 3 μs in 100 ns steps. Default: 1 μs for NaI probe\n\n• Digital Spectrum Stabilization\n\n• Automatic Baseline Restore\n\n• Automatic Fast Discriminator threshold\n\n• Seamlessly compatible with Apex InVivo Software\n\n• USB 2.0 and Ethernet 10/100BaseTX Output\n\n• 14 pin and 8 pin PMT socket compatible\n\n• Diameter less than 3.5”\n\n• Weight < 6 lbs\n\n• ACQUISITION MODES\n\n• PHA PHA Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each\n\n• Preset: ROI Counts (Integral), Real or Live Time timers\n\n• Real and Live Time Resolution: 0.01 s\n\n• Preset Time: 0 to >4 x 107 s\n\n• Control: Internal or External Start/Stop control\n\n• LTC accuracy: 5% (3% typical) up to 50 kcps\n\n• MCS\n\n• MCS Dwell range: 1 μs to 999 seconds in 1 μs steps\n\n• Sweep range: 1 to 232 -1\n\n• Preset Sweep Counter: 0 to 232 -1 Sweeps (0 implies \"Forever\")\n\n• MCS input selection: PHA ROI, external TTL or Fast Discriminator\n\n• Dwell selection: internal or external\n\n• MCS Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each\n\n• 8192 Channels Configurable as two groups of 2048, 1024, 512 or 256 channels for PHA and MCS with 32 bits per channel\n\n• Integral Non-linearity: ±0.025% of full scale over the top 99% of the selected range\n\n• Differential Non-linearity: ±1% over the top 99% of the range including the effects from integral non-linearity\n\n• Gain Drift: <75 ppm/°C after 15 minutes of operation\n\n• Incoming Count Rate (ICR): >250 K cps ICR if not limited by probe/detector\n\n• Short Circuit Protection\n\n• High Voltage Power Supply\n\n• OUTPUT: 0-1300 V at 50 μA max\n\n• RIPPLE: 1 mV — ACCURACY: 3% Full Scale\n\n• SETTING RESOLUTION: 14-bit (1/16 384)\n\nWARRANTY AND SUPPORT\n\nThe Contractor shall provide a minimum 12-calendar-month warranty covering all parts and labor.\n\nThe warranty period shall begin on the date of formal Government acceptance.\n\nWarranty service shall include repair or replacement of defective components necessary to maintain operation of the delivered system.\n\nReview the attached document for complete description of the requirement.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"75F40126Q00375","place_of_performance":{"zip":"01890","city":{"code":"80510","name":"Winchester"},"state":{"code":"MA","name":"Massachusetts"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6630"}],"due_at":"2026-08-31T18:00:00Z","due_date":"2026-08-31","closes_at":"2026-08-31T18:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75FDA1","office_name":"FDA Office of Acquisitions and Grants Services","state":"MA","county":"25017","county_name":"Middlesex County","city":"2580545","city_name":"Winchester","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-24T10:32:42.474880Z","principal_notice_id":"d3c5244a4a9a4cce939b61b0fb4802ef","description":{"text":"This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested, and a written solicitation will not be issued separately.\n\nSolicitation No.: 75F40126Q00375\n\nContracting Activity: Food and Drug Administration (FDA)\n\nOffice/Center: Office of the Commissioner (OC)\n\nAcquisition Type: Commercial Product\n\nSolicitation Type: Request for Quotation (RFQ)\n\nContract Type: Firm-Fixed-Price Purchase Order\n\nEstimated Value: $20,000\n\nRequired Delivery: September 15, 2026\n\nDELIVERABLE:\n\n1. 3X3 LED Temperature stabilized Sodium Iodide Probe compatible with Mirion Osprey Multi Channel Analyzer\n\nDelivery Date: 9/15/2026\n\n2. Digital Tube Based Multichannel Analyzer with USB and Ethernet output\n\nDelivery Date: 09/15/2026\n\nSalient Characteristics\n\nThe equipment offered shall meet or exceed all requirements listed below.\n\nDetector Characteristics\n\n• 3”X 3” NaI(Tl) LED Stabilized Scintillation Detector\n\n• Energy Range 30 keV to 3 MeV\n\n• Resolution >7%\n\n• Available with generic efficiency characterization\n\n• OPERATING HUMIDITY – 85% non-condensing\n\n• OPERATING TEMPERATURE – -20 to +50 °C (-4 to 122 °F).\n\n• Must be compatible and seamlessly compatible with Apex InVivo Software and Mirion Osprey Multichannel Digital Analyzer\n\n• Diameter less than 3.5”\n\n• Weight < 6 lbs\n\nMulti-Channel Digital Analyzer Characteristics\n\n• Includes HVPS, Preamplifier and Digital MCA\n\n• Gain Coarse Gain: x1, x2, x4, x8 software programmable\n\n• Fine Gain: x1 – x5 software programmable\n\n• Total Gain: Product of Fine Gain and Coarse Gain, x1 – x40\n\n• ADC: ADC 14-Bit 20 MHz Sampling\n\n• ULD/LLD ULD: 0% to 100% of Full Scale software programmable\n\n• LLD: 0% to 100% of Full Scale software programmable\n\n• Detector Voltage: HVPS 0 to +1300 V dc: 100 V/s ramping on power up and down\n\n• Shaping DSP Based Trapezoidal shaping filter operating at 80 MHz\n\n• Rise Time: 0.2 μs – 5 μs in 200 ns steps. Default: 1 μs for NaI probe\n\n• Flat Top: 0 to 3 μs in 100 ns steps. Default: 1 μs for NaI probe\n\n• Digital Spectrum Stabilization\n\n• Automatic Baseline Restore\n\n• Automatic Fast Discriminator threshold\n\n• Seamlessly compatible with Apex InVivo Software\n\n• USB 2.0 and Ethernet 10/100BaseTX Output\n\n• 14 pin and 8 pin PMT socket compatible\n\n• Diameter less than 3.5”\n\n• Weight < 6 lbs\n\n• ACQUISITION MODES\n\n• PHA PHA Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each\n\n• Preset: ROI Counts (Integral), Real or Live Time timers\n\n• Real and Live Time Resolution: 0.01 s\n\n• Preset Time: 0 to >4 x 107 s\n\n• Control: Internal or External Start/Stop control\n\n• LTC accuracy: 5% (3% typical) up to 50 kcps\n\n• MCS\n\n• MCS Dwell range: 1 μs to 999 seconds in 1 μs steps\n\n• Sweep range: 1 to 232 -1\n\n• Preset Sweep Counter: 0 to 232 -1 Sweeps (0 implies \"Forever\")\n\n• MCS input selection: PHA ROI, external TTL or Fast Discriminator\n\n• Dwell selection: internal or external\n\n• MCS Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each\n\n• 8192 Channels Configurable as two groups of 2048, 1024, 512 or 256 channels for PHA and MCS with 32 bits per channel\n\n• Integral Non-linearity: ±0.025% of full scale over the top 99% of the selected range\n\n• Differential Non-linearity: ±1% over the top 99% of the range including the effects from integral non-linearity\n\n• Gain Drift: <75 ppm/°C after 15 minutes of operation\n\n• Incoming Count Rate (ICR): >250 K cps ICR if not limited by probe/detector\n\n• Short Circuit Protection\n\n• High Voltage Power Supply\n\n• OUTPUT: 0-1300 V at 50 μA max\n\n• RIPPLE: 1 mV — ACCURACY: 3% Full Scale\n\n• SETTING RESOLUTION: 14-bit (1/16 384)\n\nWARRANTY AND SUPPORT\n\nThe Contractor shall provide a minimum 12-calendar-month warranty covering all parts and labor.\n\nThe warranty period shall begin on the date of formal Government acceptance.\n\nWarranty service shall include repair or replacement of defective components necessary to maintain operation of the delivered system.\n\nReview the attached document for complete description of the requirement.","html":"<p>This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested, and a written solicitation will not be issued separately.</p>\n\n<p><strong>Solicitation No.:</strong> <strong>75F40126Q00375&nbsp;</strong><br />\n<strong>Contracting Activity:</strong> Food and Drug Administration (FDA)<br />\n<strong>Office/Center:</strong> Office of the Commissioner (OC)<br />\n<strong>Acquisition Type:</strong> Commercial Product<br />\n<strong>Solicitation Type:</strong> Request for Quotation (RFQ)<br />\n<strong>Contract Type:</strong> Firm-Fixed-Price Purchase Order<br />\n<strong>Estimated Value:</strong> $20,000<br />\n<strong>Required Delivery:</strong> September 15, 2026</p>\n\n<p><u><strong>DELIVERABLE:</strong></u></p>\n\n<p>1. 3X3 LED Temperature stabilized Sodium Iodide Probe compatible with Mirion Osprey Multi Channel Analyzer</p>\n\n<p>Delivery Date: 9/15/2026</p>\n\n<p></p>\n\n<p>2. Digital Tube Based Multichannel Analyzer with USB and Ethernet output</p>\n\n<p>Delivery Date: 09/15/2026</p>\n\n<p><u><strong>Salient Characteristics</strong></u></p>\n\n<p>The equipment offered shall meet or exceed all requirements listed below.</p>\n\n<p><strong><u>Detector Characteristics</u></strong></p>\n\n<ul>\n\t<li>3&rdquo;X 3&rdquo; NaI(Tl) LED Stabilized Scintillation Detector</li>\n\t<li>Energy Range 30 keV to 3 MeV</li>\n\t<li>Resolution &gt;7%</li>\n\t<li>Available with generic efficiency characterization</li>\n\t<li>OPERATING HUMIDITY &ndash; 85% non-condensing</li>\n\t<li>OPERATING TEMPERATURE &ndash; -20 to +50 &deg;C (-4 to 122 &deg;F).</li>\n\t<li>Must be compatible and seamlessly compatible with Apex InVivo Software and Mirion Osprey Multichannel Digital Analyzer</li>\n\t<li>Diameter less than 3.5&rdquo;</li>\n\t<li>Weight &lt; 6 lbs</li>\n</ul>\n\n<p></p>\n\n<p><strong><u>Multi-Channel Digital Analyzer Characteristics</u></strong></p>\n\n<ul>\n\t<li>Includes HVPS, Preamplifier and Digital MCA</li>\n\t<li>Gain Coarse Gain: x1, x2, x4, x8 software programmable</li>\n\t<li>Fine Gain: x1 &ndash; x5 software programmable</li>\n\t<li>Total Gain: Product of Fine Gain and Coarse Gain, x1 &ndash; x40</li>\n\t<li>ADC: ADC 14-Bit 20 MHz Sampling</li>\n\t<li>ULD/LLD ULD: 0% to 100% of Full Scale software programmable</li>\n\t<li>LLD: 0% to 100% of Full Scale software programmable</li>\n\t<li>Detector Voltage: HVPS 0 to +1300 V dc: 100 V/s ramping on power up and down</li>\n\t<li>Shaping DSP Based Trapezoidal shaping filter operating at 80 MHz</li>\n\t<li>Rise Time: 0.2 &mu;s &ndash; 5 &mu;s in 200 ns steps. Default: 1 &mu;s for NaI probe</li>\n\t<li>Flat Top: 0 to 3 &mu;s in 100 ns steps. Default: 1 &mu;s for NaI probe</li>\n\t<li>Digital Spectrum Stabilization</li>\n\t<li>Automatic Baseline Restore</li>\n\t<li>Automatic Fast Discriminator threshold</li>\n\t<li>Seamlessly compatible with Apex InVivo Software</li>\n\t<li>USB 2.0 and Ethernet 10/100BaseTX Output</li>\n\t<li>14 pin and 8 pin PMT socket compatible</li>\n\t<li>Diameter less than 3.5&rdquo;</li>\n\t<li>Weight &lt; 6 lbs</li>\n\t<li>ACQUISITION MODES\n\t<ul>\n\t\t<li>PHA PHA Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each</li>\n\t\t<li>Preset: ROI Counts (Integral), Real or Live Time timers</li>\n\t\t<li>Real and Live Time Resolution: 0.01 s</li>\n\t\t<li>Preset Time: 0 to &gt;4 x 107 s</li>\n\t\t<li>Control: Internal or External Start/Stop control</li>\n\t\t<li>LTC accuracy: 5% (3% typical) up to 50 kcps</li>\n\t</ul>\n\t</li>\n\t<li>MCS\n\t<ul>\n\t\t<li>MCS Dwell range: 1 &mu;s to 999 seconds in 1 &mu;s steps</li>\n\t\t<li>Sweep range: 1 to 232 -1</li>\n\t\t<li>Preset Sweep Counter: 0 to 232 -1 Sweeps (0 implies &quot;Forever&quot;)</li>\n\t\t<li>MCS input selection: PHA ROI, external TTL or Fast Discriminator</li>\n\t\t<li>Dwell selection: internal or external</li>\n\t\t<li>MCS Channels: 256 to 2048 Channels, supports two memory groups of up to 2048 channels each</li>\n\t</ul>\n\t</li>\n\t<li>8192 Channels Configurable as two groups of 2048, 1024, 512 or 256 channels for PHA and MCS with 32 bits per channel</li>\n\t<li>Integral Non-linearity: &plusmn;0.025% of full scale over the top 99% of the selected range</li>\n\t<li>Differential Non-linearity: &plusmn;1% over the top 99% of the range including the effects from integral non-linearity</li>\n\t<li>Gain Drift: &lt;75 ppm/&deg;C after 15 minutes of operation</li>\n\t<li>Incoming Count Rate (ICR): &gt;250 K cps ICR if not limited by probe/detector</li>\n\t<li>Short Circuit Protection</li>\n\t<li>High Voltage Power Supply\n\t<ul>\n\t\t<li>OUTPUT: 0-1300 V at 50 &mu;A max</li>\n\t\t<li>RIPPLE: 1 mV &mdash; ACCURACY: 3% Full Scale</li>\n\t\t<li>SETTING RESOLUTION: 14-bit (1/16 384)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p></p>\n\n<p><strong>WARRANTY AND SUPPORT</strong></p>\n\n<p>The Contractor shall provide a minimum <strong>12-calendar-month warranty</strong> covering all parts and labor.</p>\n\n<p>The warranty period shall begin on the date of formal Government acceptance.</p>\n\n<p>Warranty service shall include repair or replacement of defective components necessary to maintain operation of the delivered system.</p>\n\n<p></p>\n\n<p>Review the attached document for complete description of the requirement.</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Lilibeth Deato","role":"primary","email":"lilibeth.deato@fda.hhs.gov","phone":"3017960349"}],"place_of_performance":{"zip":"01890","city":{"code":"80510","name":"Winchester"},"state":{"code":"MA","name":"Massachusetts"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20857","city":"Rockville","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"6936eee0a7ed48539460810b08f4aee1","name":"SOW.pdf","kind":"file","mime_type":".pdf","size_bytes":369329,"posted_at":"2026-08-25T13:58:34.099Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6936eee0a7ed48539460810b08f4aee1/download","mirrored":false}],"awards":[],"related":[],"similar_open":[{"key":"N0016427Q0014","latest_notice_id":"cbeccf2c409f4c48aedff76a3b4a4359","title":"ARBITRARY WAVEFORM GENERATOR","solicitation_number":"N0016427Q0014","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00164","office_name":"NSWC CRANE","naics":"334516","psc":"6115","set_aside":null,"state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"89243327QEX000002","latest_notice_id":"2507c3f1a48c4f2bad80f7ae604ba05a","title":"66--Brand Name or Equal Teledyne Instruments Liquid Sy","solicitation_number":"89243327QEX000002","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-892433","office_name":"NATIONAL ENERGY TECHNOLOGY LABORATORY","naics":"334516","psc":"6640","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"89243327QEX000003","latest_notice_id":"1dee4e8cc79a4245a52ca82c963125bd","title":"Brand Name or Equal Across International 2R50f.110","solicitation_number":"89243327QEX000003","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-892433","office_name":"NATIONAL ENERGY TECHNOLOGY LABORATORY","naics":"334516","psc":"6640","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open_total":59,"indexable":false}