{"canonical":"https://sealedbidder.com/opportunities/75f40126q00088","key":"75F40126Q00088","url":"https://sealedbidder.com/opportunities/75f40126q00088","title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","solicitation_number":"75F40126Q00088","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-05-07T16:00:00Z","first_posted":"2026-05-01","last_posted":"2026-05-06","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"FOOD AND DRUG ADMINISTRATION","office":"FDA OFFICE OF ACQ GRANT SVCS","naics":"334516","psc":"6640","set_aside":"SBA","place_state":"MO","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"29510","place_county_name":"City of St. Louis","place_city":"2965000","place_city_name":"St. Louis","winner":null,"award_amount":null,"publications":[{"notice_id":"cd2ff363de66495aa17b5ae4d474557e","title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","solicitation_number":"75F40126Q00088","notice_type":"k","base_type":"k","posted":"2026-05-01","posted_at":"2026-05-01T18:47:24.296Z","due_at":"2026-05-06T16:00:00Z","due_date":"2026-05-06","cancelled":false,"archived":true,"archive_date":"2026-05-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cd2ff363de66495aa17b5ae4d474557e/view","enriched":true,"history":[{"index":3,"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-06T15:15:20.141Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"daa8b5446379478e9536342d5cd69982","solicitation_number":"75F40126Q00088","parent_opportunity_id":"cd2ff363de66495aa17b5ae4d474557e"},{"index":1,"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-01T18:47:24.296Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"cd2ff363de66495aa17b5ae4d474557e","solicitation_number":"75F40126Q00088"}]},{"notice_id":"daa8b5446379478e9536342d5cd69982","title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","solicitation_number":"75F40126Q00088","notice_type":"k","base_type":"k","posted":"2026-05-06","posted_at":"2026-05-06T15:15:20.141Z","due_at":"2026-05-07T16:00:00Z","due_date":"2026-05-07","cancelled":false,"archived":true,"archive_date":"2026-05-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/daa8b5446379478e9536342d5cd69982/view","enriched":true,"history":[{"index":3,"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-06T15:15:20.141Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"daa8b5446379478e9536342d5cd69982","solicitation_number":"75F40126Q00088","parent_opportunity_id":"cd2ff363de66495aa17b5ae4d474557e"},{"index":1,"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-01T18:47:24.296Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"cd2ff363de66495aa17b5ae4d474557e","solicitation_number":"75F40126Q00088"}]}],"latest_notice_id":"daa8b5446379478e9536342d5cd69982","first_type":"k","notices":[{"dates":{"posted":"2026-05-01","posted_at":"2026-05-01T18:47:24.296Z","created_at":"2026-05-01T18:40:45.228Z","modified_at":"2026-05-09T04:06:38.805Z","response_deadline":{"raw":"2026-05-06T12:00:00-04:00","utc":"2026-05-06T16:00:00Z","date":"2026-05-06","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cd2ff363de66495aa17b5ae4d474557e/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","agency":{"office":{"code":"75F401","name":"FDA OFFICE OF ACQ GRANT SVCS"},"subtier":{"code":"7524","name":"FOOD AND DRUG ADMINISTRATION"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"organization_id":"100188033","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-07","archive_type":"auto_custom"},"history":[{"index":3,"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-06T15:15:20.141Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"daa8b5446379478e9536342d5cd69982","solicitation_number":"75F40126Q00088","parent_opportunity_id":"cd2ff363de66495aa17b5ae4d474557e"},{"index":1,"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-01T18:47:24.296Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"cd2ff363de66495aa17b5ae4d474557e","solicitation_number":"75F40126Q00088"}],"contacts":[{"name":"Reagan Davis","role":"primary","email":"reagan.davis@fda.hhs.gov","phone":"3017960910"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"cd2ff363de66495aa17b5ae4d474557e","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"cd2ff363de66495aa17b5ae4d474557e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-05T11:03:58.394550838Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"6ab61322eb082bf16ae60980c1c65798490162de557fc1d9b6c50dacf258a936","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-05T11:03:58.394550838Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The Government intends to acquire a high-resolution mass spectrometry system with ultra-high-performance liquid chromatography capability to support the analysis of pharmaceutical drug substances and drug products, including detection and characterization of nitrosamine impurities, small molecules, peptides, and other biomolecules. The Thermo Scientific Orbitrap Excedion Pro BioPharma MS and UHPLC system is referenced as the brand-name product used to define the level of performance and functionality required.</p>\n\n<p>This acquisition is conducted on a brand-name-or-equal basis. Products offered as an &ldquo;equal&rdquo; must meet or exceed the salient characteristics identified below in order to be considered technically acceptable.</p>\n\n<p>The Government requires an integrated LC-MS analytical system capable of supporting regulatory-grade analytical workflows for pharmaceutical quality evaluation and impurity characterization. The system must provide high-resolution, accurate-mass detection across a wide mass range to support both small molecule and biomolecule applications, including trace-level impurity detection and characterization of peptide-based therapeutics.</p>\n\n<p>At a minimum, the offered system shall meet the following <strong>salient characteristics</strong>:</p>\n\n<p>&bull; High-resolution accurate-mass (HRAM) mass spectrometry system capable of resolving complex mixtures and trace-level impurities in pharmaceutical samples<br />\n&bull; Mass analyzer capable of achieving resolving power sufficient for high-confidence molecular identification and impurity characterization<br />\n&bull; Extended mass range capability to analyze both small molecules and larger biomolecules (minimum mass range approximately up to m/z 12,000)<br />\n&bull; Sensitivity sufficient for trace-level detection of pharmaceutical impurities, including nitrosamines<br />\n&bull; Compatibility with an integrated ultra-high-performance liquid chromatography (UHPLC) system suitable for biocompatible analytical applications<br />\n&bull; Integrated instrument control and data analysis software capable of supporting advanced analytical workflows for small molecule and peptide characterization<br />\n&bull; Capability for automated data processing, spectral deconvolution, and identification workflows for complex pharmaceutical samples<br />\n&bull; Centralized data management capability supporting secure instrument operation, workflow automation, and laboratory data integration<br />\n&bull; Delivery, installation, and instrument qualification (IQ/OQ) services for the complete LC-MS system<br />\n&bull; Vendor-provided instrument familiarization and operational training</p>\n\n<p>&bull; Minimum one (1) year manufacturer warranty covering parts, labor, travel, and OEM-certified service support, beginning upon Government acceptance of the system</p>\n\n<p>The Government will evaluate quotations offering the referenced brand-name product or <strong>equal products</strong> that meet the above salient characteristics. Offerors proposing an equal product must clearly demonstrate in their quotation how the proposed equipment meets or exceeds each of the required salient characteristics.</p>","text":"The Government intends to acquire a high-resolution mass spectrometry system with ultra-high-performance liquid chromatography capability to support the analysis of pharmaceutical drug substances and drug products, including detection and characterization of nitrosamine impurities, small molecules, peptides, and other biomolecules. The Thermo Scientific Orbitrap Excedion Pro BioPharma MS and UHPLC system is referenced as the brand-name product used to define the level of performance and functionality required.\n\nThis acquisition is conducted on a brand-name-or-equal basis. Products offered as an “equal” must meet or exceed the salient characteristics identified below in order to be considered technically acceptable.\n\nThe Government requires an integrated LC-MS analytical system capable of supporting regulatory-grade analytical workflows for pharmaceutical quality evaluation and impurity characterization. The system must provide high-resolution, accurate-mass detection across a wide mass range to support both small molecule and biomolecule applications, including trace-level impurity detection and characterization of peptide-based therapeutics.\n\nAt a minimum, the offered system shall meet the following salient characteristics:\n\n• High-resolution accurate-mass (HRAM) mass spectrometry system capable of resolving complex mixtures and trace-level impurities in pharmaceutical samples\n\n• Mass analyzer capable of achieving resolving power sufficient for high-confidence molecular identification and impurity characterization\n\n• Extended mass range capability to analyze both small molecules and larger biomolecules (minimum mass range approximately up to m/z 12,000)\n\n• Sensitivity sufficient for trace-level detection of pharmaceutical impurities, including nitrosamines\n\n• Compatibility with an integrated ultra-high-performance liquid chromatography (UHPLC) system suitable for biocompatible analytical applications\n\n• Integrated instrument control and data analysis software capable of supporting advanced analytical workflows for small molecule and peptide characterization\n\n• Capability for automated data processing, spectral deconvolution, and identification workflows for complex pharmaceutical samples\n\n• Centralized data management capability supporting secure instrument operation, workflow automation, and laboratory data integration\n\n• Delivery, installation, and instrument qualification (IQ/OQ) services for the complete LC-MS system\n\n• Vendor-provided instrument familiarization and operational training\n\n• Minimum one (1) year manufacturer warranty covering parts, labor, travel, and OEM-certified service support, beginning upon Government acceptance of the system\n\nThe Government will evaluate quotations offering the referenced brand-name product or equal products that meet the above salient characteristics. Offerors proposing an equal product must clearly demonstrate in their quotation how the proposed equipment meets or exceeds each of the required salient characteristics.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"75F40126Q00088","place_of_performance":{"zip":"63110","city":{"code":"65000","name":"Saint Louis"},"state":{"code":"MO","name":"Missouri"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"},{"dates":{"posted":"2026-05-06","posted_at":"2026-05-06T15:15:20.141Z","created_at":"2026-05-06T15:14:26.236Z","modified_at":"2026-05-09T04:06:38.805Z","response_deadline":{"raw":"2026-05-07T12:00:00-04:00","utc":"2026-05-07T16:00:00Z","date":"2026-05-07","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/daa8b5446379478e9536342d5cd69982/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","agency":{"office":{"code":"75F401","name":"FDA OFFICE OF ACQ GRANT SVCS"},"subtier":{"code":"7524","name":"FOOD AND DRUG ADMINISTRATION"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"organization_id":"100188033","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-08","archive_type":"auto_custom"},"history":[{"index":3,"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-06T15:15:20.141Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"daa8b5446379478e9536342d5cd69982","solicitation_number":"75F40126Q00088","parent_opportunity_id":"cd2ff363de66495aa17b5ae4d474557e"},{"index":1,"title":"Orbitrap Excedion Pro BioPharma Mass Spectrometer and UHPLC","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-01T18:47:24.296Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"cd2ff363de66495aa17b5ae4d474557e","solicitation_number":"75F40126Q00088"}],"contacts":[{"name":"Reagan Davis","role":"primary","email":"reagan.davis@fda.hhs.gov","phone":"3017960910"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"daa8b5446379478e9536342d5cd69982","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"cd2ff363de66495aa17b5ae4d474557e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-05T04:13:20.088449917Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"ea5a375841d15748b95c5b765ba00127f1afa67dc3013ff10f006ddeb46f26a8","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-05T04:13:20.088449917Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The Government intends to acquire a high-resolution mass spectrometry system with ultra-high-performance liquid chromatography capability to support the analysis of pharmaceutical drug substances and drug products, including detection and characterization of nitrosamine impurities, small molecules, peptides, and other biomolecules. The Thermo Scientific Orbitrap Excedion Pro BioPharma MS and UHPLC system is referenced as the brand-name product used to define the level of performance and functionality required.</p>\n\n<p>This acquisition is conducted on a brand-name-or-equal basis. Products offered as an &ldquo;equal&rdquo; must meet or exceed the salient characteristics identified below in order to be considered technically acceptable.</p>\n\n<p>The Government requires an integrated LC-MS analytical system capable of supporting regulatory-grade analytical workflows for pharmaceutical quality evaluation and impurity characterization. The system must provide high-resolution, accurate-mass detection across a wide mass range to support both small molecule and biomolecule applications, including trace-level impurity detection and characterization of peptide-based therapeutics.</p>\n\n<p>At a minimum, the offered system shall meet the following <strong>salient characteristics</strong>:</p>\n\n<p>&bull; High-resolution accurate-mass (HRAM) mass spectrometry system capable of resolving complex mixtures and trace-level impurities in pharmaceutical samples<br />\n&bull; Mass analyzer capable of achieving resolving power sufficient for high-confidence molecular identification and impurity characterization<br />\n&bull; Extended mass range capability to analyze both small molecules and larger biomolecules (minimum mass range approximately up to m/z 12,000)<br />\n&bull; Sensitivity sufficient for trace-level detection of pharmaceutical impurities, including nitrosamines<br />\n&bull; Compatibility with an integrated ultra-high-performance liquid chromatography (UHPLC) system suitable for biocompatible analytical applications<br />\n&bull; Integrated instrument control and data analysis software capable of supporting advanced analytical workflows for small molecule and peptide characterization<br />\n&bull; Capability for automated data processing, spectral deconvolution, and identification workflows for complex pharmaceutical samples<br />\n&bull; Centralized data management capability supporting secure instrument operation, workflow automation, and laboratory data integration<br />\n&bull; Delivery, installation, and instrument qualification (IQ/OQ) services for the complete LC-MS system<br />\n&bull; Vendor-provided instrument familiarization and operational training</p>\n\n<p>&bull; Minimum one (1) year manufacturer warranty covering parts, labor, travel, and OEM-certified service support, beginning upon Government acceptance of the system</p>\n\n<p>The Government will evaluate quotations offering the referenced brand-name product or <strong>equal products</strong> that meet the above salient characteristics. Offerors proposing an equal product must clearly demonstrate in their quotation how the proposed equipment meets or exceeds each of the required salient characteristics.</p>","text":"The Government intends to acquire a high-resolution mass spectrometry system with ultra-high-performance liquid chromatography capability to support the analysis of pharmaceutical drug substances and drug products, including detection and characterization of nitrosamine impurities, small molecules, peptides, and other biomolecules. The Thermo Scientific Orbitrap Excedion Pro BioPharma MS and UHPLC system is referenced as the brand-name product used to define the level of performance and functionality required.\n\nThis acquisition is conducted on a brand-name-or-equal basis. Products offered as an “equal” must meet or exceed the salient characteristics identified below in order to be considered technically acceptable.\n\nThe Government requires an integrated LC-MS analytical system capable of supporting regulatory-grade analytical workflows for pharmaceutical quality evaluation and impurity characterization. The system must provide high-resolution, accurate-mass detection across a wide mass range to support both small molecule and biomolecule applications, including trace-level impurity detection and characterization of peptide-based therapeutics.\n\nAt a minimum, the offered system shall meet the following salient characteristics:\n\n• High-resolution accurate-mass (HRAM) mass spectrometry system capable of resolving complex mixtures and trace-level impurities in pharmaceutical samples\n\n• Mass analyzer capable of achieving resolving power sufficient for high-confidence molecular identification and impurity characterization\n\n• Extended mass range capability to analyze both small molecules and larger biomolecules (minimum mass range approximately up to m/z 12,000)\n\n• Sensitivity sufficient for trace-level detection of pharmaceutical impurities, including nitrosamines\n\n• Compatibility with an integrated ultra-high-performance liquid chromatography (UHPLC) system suitable for biocompatible analytical applications\n\n• Integrated instrument control and data analysis software capable of supporting advanced analytical workflows for small molecule and peptide characterization\n\n• Capability for automated data processing, spectral deconvolution, and identification workflows for complex pharmaceutical samples\n\n• Centralized data management capability supporting secure instrument operation, workflow automation, and laboratory data integration\n\n• Delivery, installation, and instrument qualification (IQ/OQ) services for the complete LC-MS system\n\n• Vendor-provided instrument familiarization and operational training\n\n• Minimum one (1) year manufacturer warranty covering parts, labor, travel, and OEM-certified service support, beginning upon Government acceptance of the system\n\nThe Government will evaluate quotations offering the referenced brand-name product or equal products that meet the above salient characteristics. Offerors proposing an equal product must clearly demonstrate in their quotation how the proposed equipment meets or exceeds each of the required salient characteristics.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"75F40126Q00088","place_of_performance":{"zip":"63110","city":{"code":"65000","name":"Saint Louis"},"state":{"code":"MO","name":"Missouri"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6640"}],"due_at":"2026-05-07T16:00:00Z","due_date":"2026-05-07","closes_at":"2026-05-07T16:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","state":"MO","county":"29510","county_name":"City of St. Louis","city":"2965000","city_name":"St. Louis","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-05T04:46:55.746237Z","principal_notice_id":"daa8b5446379478e9536342d5cd69982","description":{"text":"The Government intends to acquire a high-resolution mass spectrometry system with ultra-high-performance liquid chromatography capability to support the analysis of pharmaceutical drug substances and drug products, including detection and characterization of nitrosamine impurities, small molecules, peptides, and other biomolecules. The Thermo Scientific Orbitrap Excedion Pro BioPharma MS and UHPLC system is referenced as the brand-name product used to define the level of performance and functionality required.\n\nThis acquisition is conducted on a brand-name-or-equal basis. Products offered as an “equal” must meet or exceed the salient characteristics identified below in order to be considered technically acceptable.\n\nThe Government requires an integrated LC-MS analytical system capable of supporting regulatory-grade analytical workflows for pharmaceutical quality evaluation and impurity characterization. The system must provide high-resolution, accurate-mass detection across a wide mass range to support both small molecule and biomolecule applications, including trace-level impurity detection and characterization of peptide-based therapeutics.\n\nAt a minimum, the offered system shall meet the following salient characteristics:\n\n• High-resolution accurate-mass (HRAM) mass spectrometry system capable of resolving complex mixtures and trace-level impurities in pharmaceutical samples\n\n• Mass analyzer capable of achieving resolving power sufficient for high-confidence molecular identification and impurity characterization\n\n• Extended mass range capability to analyze both small molecules and larger biomolecules (minimum mass range approximately up to m/z 12,000)\n\n• Sensitivity sufficient for trace-level detection of pharmaceutical impurities, including nitrosamines\n\n• Compatibility with an integrated ultra-high-performance liquid chromatography (UHPLC) system suitable for biocompatible analytical applications\n\n• Integrated instrument control and data analysis software capable of supporting advanced analytical workflows for small molecule and peptide characterization\n\n• Capability for automated data processing, spectral deconvolution, and identification workflows for complex pharmaceutical samples\n\n• Centralized data management capability supporting secure instrument operation, workflow automation, and laboratory data integration\n\n• Delivery, installation, and instrument qualification (IQ/OQ) services for the complete LC-MS system\n\n• Vendor-provided instrument familiarization and operational training\n\n• Minimum one (1) year manufacturer warranty covering parts, labor, travel, and OEM-certified service support, beginning upon Government acceptance of the system\n\nThe Government will evaluate quotations offering the referenced brand-name product or equal products that meet the above salient characteristics. Offerors proposing an equal product must clearly demonstrate in their quotation how the proposed equipment meets or exceeds each of the required salient characteristics.","html":"<p>The Government intends to acquire a high-resolution mass spectrometry system with ultra-high-performance liquid chromatography capability to support the analysis of pharmaceutical drug substances and drug products, including detection and characterization of nitrosamine impurities, small molecules, peptides, and other biomolecules. The Thermo Scientific Orbitrap Excedion Pro BioPharma MS and UHPLC system is referenced as the brand-name product used to define the level of performance and functionality required.</p>\n\n<p>This acquisition is conducted on a brand-name-or-equal basis. Products offered as an &ldquo;equal&rdquo; must meet or exceed the salient characteristics identified below in order to be considered technically acceptable.</p>\n\n<p>The Government requires an integrated LC-MS analytical system capable of supporting regulatory-grade analytical workflows for pharmaceutical quality evaluation and impurity characterization. The system must provide high-resolution, accurate-mass detection across a wide mass range to support both small molecule and biomolecule applications, including trace-level impurity detection and characterization of peptide-based therapeutics.</p>\n\n<p>At a minimum, the offered system shall meet the following <strong>salient characteristics</strong>:</p>\n\n<p>&bull; High-resolution accurate-mass (HRAM) mass spectrometry system capable of resolving complex mixtures and trace-level impurities in pharmaceutical samples<br />\n&bull; Mass analyzer capable of achieving resolving power sufficient for high-confidence molecular identification and impurity characterization<br />\n&bull; Extended mass range capability to analyze both small molecules and larger biomolecules (minimum mass range approximately up to m/z 12,000)<br />\n&bull; Sensitivity sufficient for trace-level detection of pharmaceutical impurities, including nitrosamines<br />\n&bull; Compatibility with an integrated ultra-high-performance liquid chromatography (UHPLC) system suitable for biocompatible analytical applications<br />\n&bull; Integrated instrument control and data analysis software capable of supporting advanced analytical workflows for small molecule and peptide characterization<br />\n&bull; Capability for automated data processing, spectral deconvolution, and identification workflows for complex pharmaceutical samples<br />\n&bull; Centralized data management capability supporting secure instrument operation, workflow automation, and laboratory data integration<br />\n&bull; Delivery, installation, and instrument qualification (IQ/OQ) services for the complete LC-MS system<br />\n&bull; Vendor-provided instrument familiarization and operational training</p>\n\n<p>&bull; Minimum one (1) year manufacturer warranty covering parts, labor, travel, and OEM-certified service support, beginning upon Government acceptance of the system</p>\n\n<p>The Government will evaluate quotations offering the referenced brand-name product or <strong>equal products</strong> that meet the above salient characteristics. Offerors proposing an equal product must clearly demonstrate in their quotation how the proposed equipment meets or exceeds each of the required salient characteristics.</p>","origin":"detail"},"contacts":[{"name":"Reagan Davis","role":"primary","email":"reagan.davis@fda.hhs.gov","phone":"3017960910"}],"place_of_performance":{"zip":"63110","city":{"code":"65000","name":"Saint Louis"},"state":{"code":"MO","name":"Missouri"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"6fdfca20ed0c4ae0ac9658be7f7e8450","name":"Combined_Syn.docx","kind":"file","mime_type":".docx","size_bytes":56725,"posted_at":"2026-05-01T18:47:24.296Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6fdfca20ed0c4ae0ac9658be7f7e8450/download","mirrored":false}],"awards":[],"related":[{"key":"75F40126Q136817","latest_notice_id":"955053716c304fb9b9627b268abe4a42","title":"Service agreement on a Randox Daytona Plus Chemistry Analyzer Instrument","solicitation_number":"75F40126Q136817","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"811210","psc":"J066","set_aside":null,"state":"AR","county":"05069","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"FDA2026136896","latest_notice_id":"2e4e031f692445cab046a32280d4215a","title":"Adverse Events Monitoring Systems (AEMS)","solicitation_number":"FDA-2026-136896","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-03T17:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":null,"psc":null,"set_aside":null,"state":"MD","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"75F40127R00002","latest_notice_id":"780583ad411042e2a84176f5a8d15163","title":"Preventative Maintenance of Above Standard Equipment (ASE) FDA National Capital Region","solicitation_number":"75F40127R00002","notice_type":"p","first_type":"p","first_posted":"2026-11-21","last_posted":"2026-11-21","notices":1,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"811210","psc":"J066","set_aside":"SBA","state":"MD","county":"24031","county_name":"Montgomery County","city":"2472450","city_name":"Silver Spring","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-22T05:17:48.835238Z"},{"key":"FDARFQ136450","latest_notice_id":"f5ae38bc3a004364b3e486c0f046d6dd","title":"JamF Software Licenses","solicitation_number":"FDA_RFQ_136450","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-07T18:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"513210","psc":"7A20","set_aside":"SBA","state":"MD","county":"24031","county_name":"Montgomery County","city":"2467675","city_name":"Rockville","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FDA27137158","latest_notice_id":"b3625b61a12d41bc93867c0d5ee840db","title":"NOTICE OF INTENT TO AWARD SOLE SOURCE FOR POLICE ORDERS","solicitation_number":"FDA-27-137158","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-07T22:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"922120","psc":"R499","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2467675","city_name":"Rockville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open":[{"key":"W911S227U0167","latest_notice_id":"329dd9aaa84845dbba2130418ce2ad17","title":"Incubator Shaker","solicitation_number":"W911S227U0167","notice_type":"k","first_type":"k","first_posted":"2026-11-11","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"BUILDING 753 CULLUM ROAD, WEST POINT NY, 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"W911S227U0166","latest_notice_id":"55af918bb27d41c29cf8b4f1c1cd01e9","title":"iWorx","solicitation_number":"W911S227U0166","notice_type":"k","first_type":"k","first_posted":"2026-11-11","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-26T16:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"BUILDING 753 CULLUM ROAD, WEST POINT NY, 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"FA860127Q0031","latest_notice_id":"f5af57335c7f467ab5c22552405fa16b","title":"NANO-AEROSOL HYGROSCOPICITY- CLOUD CONDENSATION ANALYZER","solicitation_number":"FA860127Q0031","notice_type":"r","first_type":"r","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8601","office_name":"FA8601 AFLCMC PZIO","naics":"334516","psc":"6640","set_aside":null,"state":"OH","county":"39057","county_name":"Greene County","city":"3986660","city_name":"Wright-Patterson AFB","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open_total":53,"indexable":false}