{"canonical":"https://sealedbidder.com/opportunities/75f40125q130500","key":"75F40125Q130500","url":"https://sealedbidder.com/opportunities/75f40125q130500","title":"Litron Multiflow and Microflow Kits","solicitation_number":"75F40125Q130500","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-07-16T06:00:00Z","first_posted":"2025-07-10","last_posted":"2025-07-10","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"FOOD AND DRUG ADMINISTRATION","office":"FDA OFFICE OF ACQ GRANT SVCS","naics":"325414","psc":"6505","set_aside":null,"place_state":"AR","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"05069","place_county_name":"Jefferson County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"11e8d07185a74031891aee59ad5d42d5","title":"Litron Multiflow and Microflow Kits","solicitation_number":"75F40125Q130500","notice_type":"k","base_type":"k","posted":"2025-07-10","posted_at":"2025-07-10T18:15:24.143Z","due_at":"2025-07-16T06:00:00Z","due_date":"2025-07-16","cancelled":false,"archived":true,"archive_date":"2025-07-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/11e8d07185a74031891aee59ad5d42d5/view","enriched":true,"history":[{"index":3,"title":"Litron Multiflow and Microflow Kits","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-10T18:15:24.143Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"11e8d07185a74031891aee59ad5d42d5","solicitation_number":"75F40125Q130500"}]}],"latest_notice_id":"11e8d07185a74031891aee59ad5d42d5","first_type":"k","notices":[{"dates":{"posted":"2025-07-10","posted_at":"2025-07-10T18:15:24.143Z","created_at":"2025-07-10T18:09:34.957Z","modified_at":"2025-08-01T03:55:47.581Z","response_deadline":{"raw":"2025-07-16T01:00:00-05:00","utc":"2025-07-16T06:00:00Z","date":"2025-07-16","time":"01:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/11e8d07185a74031891aee59ad5d42d5/view"},"naics":{"codes":["325414"],"primary":"325414"},"title":"Litron Multiflow and Microflow Kits","agency":{"office":{"code":"75F401","name":"FDA OFFICE OF ACQ GRANT SVCS"},"subtier":{"code":"7524","name":"FOOD AND DRUG ADMINISTRATION"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"organization_id":"100188033","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-31","archive_type":"auto15"},"history":[{"index":3,"title":"Litron Multiflow and Microflow Kits","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-10T18:15:24.143Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"11e8d07185a74031891aee59ad5d42d5","solicitation_number":"75F40125Q130500"}],"contacts":[{"name":"Howard Nesmith","role":"primary","email":"howard.nesmith@fda.hhs.gov","phone":"8705437459"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"11e8d07185a74031891aee59ad5d42d5","lineage_id":"11e8d07185a74031891aee59ad5d42d5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-10T03:35:31.737740121Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"9349bbbfd8c58b787321565e91a49249034b0fc90055001b883514ebe6321797","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-10T03:35:31.737740121Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>Single Source Acquisition Notification&nbsp;75F40125Q130500</p>\n\n<p><br />\nThe Food and Drug Administration (FDA)/National Center for Toxicological Research (NCTR intends to award a Purchase Order on a Single Source basis to Litron Laboratories LTD, 3500 Winton Pl, Rochester, NY 14623, under the authority of FAR 13.106-1(b)(1), Only one Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements.</p>\n\n<p>The FDA/NCTR requires four (4) MicroFlow In-vitro-1,000/200 kits and six (6) MultiFlow DNA Damage &ndash; p53, yH2AX, and Phospho-Histone H3 kits, which will be used for assessing potential genotoxicity of FDA-regulated products (ICH guideline approved).</p>\n\n<p>The associated North American Industry Classification System (NAICS) Code 325414 - Biological Product (except Diagnostic) Manufacturing; with a Small Business Size Standard of 1,250 employees</p>\n\n<p>This notice is being published in accordance with Federal Acquisition Regulation (FAR) Part 5.101(a)(1) requiring the dissemination of information on proposed contract actions. This is a notice of intent to award a sole source contract and is not a request for competitive proposals. The statutory authority for this sole-source procurement is FAR 13.106-1(b)(1).</p>\n\n<p>Any firm that believes they can provide the required item(s) as stated herein may submit their capability statement referencing Solicitation 75F40125Q130500 to document their ability on or before July 16, 2025 by 1:00 PM Central Time - Local Prevailing Time in Jefferson, Arkansas by e-Mail to howard.nesmith@fda.hhs.gov. A determination to compete this procurement based on<br />\na response to this notice is solely within the discretion of the government.</p>\n\n<p>Minimum Technical Requirements:<br />\n&bull; In-vitro Micronucleus Kit shall be capable of being used to analyze in vitro samples via flow cytometer using a Becton Dickinson FACSCanto II with a High Throughput auto Sampler (HTS).<br />\n&nbsp; o Each kit shall contain sufficient quality assured reagents and supplies to analyze 1,000 samples in 96-well plate format or 200 samples in larger microtube format.<br />\n&nbsp; o Each kit shall allow automated scoring by flow cytometry.<br />\n&nbsp; o Each kit shall be compatible with 96 well plates, as well as autosamplers and robotics.<br />\n&nbsp; o Each kit shall be compatible with many different cell lines (more than one type).<br />\n&nbsp; o Each kit shall be compatible with cells which grow in attachment or suspension.<br />\n&nbsp; o Supplier shall provide unlimited technical support.<br />\n&nbsp; o Each kit shall be compatible for use with a variety of attachment and suspension cell lines including L5178Y, CHO-K1, TK6, V79, WIL-2, and HepG2, among others.<br />\n&nbsp; o Each kit shall be capable of detecting multiple Modes-of-Action.<br />\n&bull; Each MultiFlow DNA Damage Kit shall contain all of the quality assured supplies and reagents to study multiple endpoints associated with DNA damage response pathways.<br />\n&nbsp; o Endpoints shall include p53 as an indicator of nuclear p53, &gamma;H2AX as a measure<br />\nof DNA double strand breaks, and phospho-histone H3 to label mitotic cells.<br />\n&bull; Kits shall arrive in multiple boxes due to the various temperature requirements (some on<br />\ndry ice, some on wet ice, and some at room temperature).<br />\n&bull; Kits shall be delivered in a single delivery to NCTR within 90 days of contract award<br />\nusing the required shipping method to ensure safe and proper arrival of item.</p>\n\n<p>Single Source Determination Based Upon:<br />\n&bull; The required kits have been used for more than 10years to assess the genotoxicity of<br />\nvarious chemicals or chemical mixtures in several protocols.<br />\n&bull; Litron Laboratories is the owner and manufacturer of the assay kits and is the only known<br />\nseller of the kits.<br />\n&bull; No additional sources have been identified as being capable of providing the required<br />\nkits.<br />\n&bull; Data generated from associated projects have been used to support other FDA Centers for<br />\nregulatory decision-making and published in peer-reviewed journals.<br />\n&bull; Competing this requirement would result in significant detrimental delays in fulfilling<br />\nAgency&rsquo;s requirement.<br />\n&bull; Acquisition of these kits are essential for the continuity of the data collection; past,<br />\npresent, and future.<br />\n&bull; A change in provider would compromise the integrity of future study and impact the<br />\nentire research program.<br />\n&bull; In an effort to maintain continuity and consistency, FDA/NCTR intends to purchase the<br />\nrequired kits from Litron Laboratories.</p>","text":"Single Source Acquisition Notification 75F40125Q130500\n\nThe Food and Drug Administration (FDA)/National Center for Toxicological Research (NCTR intends to award a Purchase Order on a Single Source basis to Litron Laboratories LTD, 3500 Winton Pl, Rochester, NY 14623, under the authority of FAR 13.106-1(b)(1), Only one Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements.\n\nThe FDA/NCTR requires four (4) MicroFlow In-vitro-1,000/200 kits and six (6) MultiFlow DNA Damage – p53, yH2AX, and Phospho-Histone H3 kits, which will be used for assessing potential genotoxicity of FDA-regulated products (ICH guideline approved).\n\nThe associated North American Industry Classification System (NAICS) Code 325414 - Biological Product (except Diagnostic) Manufacturing; with a Small Business Size Standard of 1,250 employees\n\nThis notice is being published in accordance with Federal Acquisition Regulation (FAR) Part 5.101(a)(1) requiring the dissemination of information on proposed contract actions. This is a notice of intent to award a sole source contract and is not a request for competitive proposals. The statutory authority for this sole-source procurement is FAR 13.106-1(b)(1).\n\nAny firm that believes they can provide the required item(s) as stated herein may submit their capability statement referencing Solicitation 75F40125Q130500 to document their ability on or before July 16, 2025 by 1:00 PM Central Time - Local Prevailing Time in Jefferson, Arkansas by e-Mail to howard.nesmith@fda.hhs.gov. A determination to compete this procurement based on\n\na response to this notice is solely within the discretion of the government.\n\nMinimum Technical Requirements:\n\n• In-vitro Micronucleus Kit shall be capable of being used to analyze in vitro samples via flow cytometer using a Becton Dickinson FACSCanto II with a High Throughput auto Sampler (HTS).\n\no Each kit shall contain sufficient quality assured reagents and supplies to analyze 1,000 samples in 96-well plate format or 200 samples in larger microtube format.\n\no Each kit shall allow automated scoring by flow cytometry.\n\no Each kit shall be compatible with 96 well plates, as well as autosamplers and robotics.\n\no Each kit shall be compatible with many different cell lines (more than one type).\n\no Each kit shall be compatible with cells which grow in attachment or suspension.\n\no Supplier shall provide unlimited technical support.\n\no Each kit shall be compatible for use with a variety of attachment and suspension cell lines including L5178Y, CHO-K1, TK6, V79, WIL-2, and HepG2, among others.\n\no Each kit shall be capable of detecting multiple Modes-of-Action.\n\n• Each MultiFlow DNA Damage Kit shall contain all of the quality assured supplies and reagents to study multiple endpoints associated with DNA damage response pathways.\n\no Endpoints shall include p53 as an indicator of nuclear p53, γH2AX as a measure\n\nof DNA double strand breaks, and phospho-histone H3 to label mitotic cells.\n\n• Kits shall arrive in multiple boxes due to the various temperature requirements (some on\n\ndry ice, some on wet ice, and some at room temperature).\n\n• Kits shall be delivered in a single delivery to NCTR within 90 days of contract award\n\nusing the required shipping method to ensure safe and proper arrival of item.\n\nSingle Source Determination Based Upon:\n\n• The required kits have been used for more than 10years to assess the genotoxicity of\n\nvarious chemicals or chemical mixtures in several protocols.\n\n• Litron Laboratories is the owner and manufacturer of the assay kits and is the only known\n\nseller of the kits.\n\n• No additional sources have been identified as being capable of providing the required\n\nkits.\n\n• Data generated from associated projects have been used to support other FDA Centers for\n\nregulatory decision-making and published in peer-reviewed journals.\n\n• Competing this requirement would result in significant detrimental delays in fulfilling\n\nAgency’s requirement.\n\n• Acquisition of these kits are essential for the continuity of the data collection; past,\n\npresent, and future.\n\n• A change in provider would compromise the integrity of future study and impact the\n\nentire research program.\n\n• In an effort to maintain continuity and consistency, FDA/NCTR intends to purchase the\n\nrequired kits from Litron Laboratories.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"75F40125Q130500","place_of_performance":{"zip":"72079","city":{"code":"34945","name":"Jefferson"},"state":{"code":"AR","name":"Arkansas"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6505"}],"due_at":"2025-07-16T06:00:00Z","due_date":"2025-07-16","closes_at":"2025-07-16T06:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","state":"AR","county":"05069","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-10T03:36:52.626874Z","principal_notice_id":"11e8d07185a74031891aee59ad5d42d5","description":{"text":"Single Source Acquisition Notification 75F40125Q130500\n\nThe Food and Drug Administration (FDA)/National Center for Toxicological Research (NCTR intends to award a Purchase Order on a Single Source basis to Litron Laboratories LTD, 3500 Winton Pl, Rochester, NY 14623, under the authority of FAR 13.106-1(b)(1), Only one Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements.\n\nThe FDA/NCTR requires four (4) MicroFlow In-vitro-1,000/200 kits and six (6) MultiFlow DNA Damage – p53, yH2AX, and Phospho-Histone H3 kits, which will be used for assessing potential genotoxicity of FDA-regulated products (ICH guideline approved).\n\nThe associated North American Industry Classification System (NAICS) Code 325414 - Biological Product (except Diagnostic) Manufacturing; with a Small Business Size Standard of 1,250 employees\n\nThis notice is being published in accordance with Federal Acquisition Regulation (FAR) Part 5.101(a)(1) requiring the dissemination of information on proposed contract actions. This is a notice of intent to award a sole source contract and is not a request for competitive proposals. The statutory authority for this sole-source procurement is FAR 13.106-1(b)(1).\n\nAny firm that believes they can provide the required item(s) as stated herein may submit their capability statement referencing Solicitation 75F40125Q130500 to document their ability on or before July 16, 2025 by 1:00 PM Central Time - Local Prevailing Time in Jefferson, Arkansas by e-Mail to howard.nesmith@fda.hhs.gov. A determination to compete this procurement based on\n\na response to this notice is solely within the discretion of the government.\n\nMinimum Technical Requirements:\n\n• In-vitro Micronucleus Kit shall be capable of being used to analyze in vitro samples via flow cytometer using a Becton Dickinson FACSCanto II with a High Throughput auto Sampler (HTS).\n\no Each kit shall contain sufficient quality assured reagents and supplies to analyze 1,000 samples in 96-well plate format or 200 samples in larger microtube format.\n\no Each kit shall allow automated scoring by flow cytometry.\n\no Each kit shall be compatible with 96 well plates, as well as autosamplers and robotics.\n\no Each kit shall be compatible with many different cell lines (more than one type).\n\no Each kit shall be compatible with cells which grow in attachment or suspension.\n\no Supplier shall provide unlimited technical support.\n\no Each kit shall be compatible for use with a variety of attachment and suspension cell lines including L5178Y, CHO-K1, TK6, V79, WIL-2, and HepG2, among others.\n\no Each kit shall be capable of detecting multiple Modes-of-Action.\n\n• Each MultiFlow DNA Damage Kit shall contain all of the quality assured supplies and reagents to study multiple endpoints associated with DNA damage response pathways.\n\no Endpoints shall include p53 as an indicator of nuclear p53, γH2AX as a measure\n\nof DNA double strand breaks, and phospho-histone H3 to label mitotic cells.\n\n• Kits shall arrive in multiple boxes due to the various temperature requirements (some on\n\ndry ice, some on wet ice, and some at room temperature).\n\n• Kits shall be delivered in a single delivery to NCTR within 90 days of contract award\n\nusing the required shipping method to ensure safe and proper arrival of item.\n\nSingle Source Determination Based Upon:\n\n• The required kits have been used for more than 10years to assess the genotoxicity of\n\nvarious chemicals or chemical mixtures in several protocols.\n\n• Litron Laboratories is the owner and manufacturer of the assay kits and is the only known\n\nseller of the kits.\n\n• No additional sources have been identified as being capable of providing the required\n\nkits.\n\n• Data generated from associated projects have been used to support other FDA Centers for\n\nregulatory decision-making and published in peer-reviewed journals.\n\n• Competing this requirement would result in significant detrimental delays in fulfilling\n\nAgency’s requirement.\n\n• Acquisition of these kits are essential for the continuity of the data collection; past,\n\npresent, and future.\n\n• A change in provider would compromise the integrity of future study and impact the\n\nentire research program.\n\n• In an effort to maintain continuity and consistency, FDA/NCTR intends to purchase the\n\nrequired kits from Litron Laboratories.","html":"<p>Single Source Acquisition Notification&nbsp;75F40125Q130500</p>\n\n<p><br />\nThe Food and Drug Administration (FDA)/National Center for Toxicological Research (NCTR intends to award a Purchase Order on a Single Source basis to Litron Laboratories LTD, 3500 Winton Pl, Rochester, NY 14623, under the authority of FAR 13.106-1(b)(1), Only one Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements.</p>\n\n<p>The FDA/NCTR requires four (4) MicroFlow In-vitro-1,000/200 kits and six (6) MultiFlow DNA Damage &ndash; p53, yH2AX, and Phospho-Histone H3 kits, which will be used for assessing potential genotoxicity of FDA-regulated products (ICH guideline approved).</p>\n\n<p>The associated North American Industry Classification System (NAICS) Code 325414 - Biological Product (except Diagnostic) Manufacturing; with a Small Business Size Standard of 1,250 employees</p>\n\n<p>This notice is being published in accordance with Federal Acquisition Regulation (FAR) Part 5.101(a)(1) requiring the dissemination of information on proposed contract actions. This is a notice of intent to award a sole source contract and is not a request for competitive proposals. The statutory authority for this sole-source procurement is FAR 13.106-1(b)(1).</p>\n\n<p>Any firm that believes they can provide the required item(s) as stated herein may submit their capability statement referencing Solicitation 75F40125Q130500 to document their ability on or before July 16, 2025 by 1:00 PM Central Time - Local Prevailing Time in Jefferson, Arkansas by e-Mail to howard.nesmith@fda.hhs.gov. A determination to compete this procurement based on<br />\na response to this notice is solely within the discretion of the government.</p>\n\n<p>Minimum Technical Requirements:<br />\n&bull; In-vitro Micronucleus Kit shall be capable of being used to analyze in vitro samples via flow cytometer using a Becton Dickinson FACSCanto II with a High Throughput auto Sampler (HTS).<br />\n&nbsp; o Each kit shall contain sufficient quality assured reagents and supplies to analyze 1,000 samples in 96-well plate format or 200 samples in larger microtube format.<br />\n&nbsp; o Each kit shall allow automated scoring by flow cytometry.<br />\n&nbsp; o Each kit shall be compatible with 96 well plates, as well as autosamplers and robotics.<br />\n&nbsp; o Each kit shall be compatible with many different cell lines (more than one type).<br />\n&nbsp; o Each kit shall be compatible with cells which grow in attachment or suspension.<br />\n&nbsp; o Supplier shall provide unlimited technical support.<br />\n&nbsp; o Each kit shall be compatible for use with a variety of attachment and suspension cell lines including L5178Y, CHO-K1, TK6, V79, WIL-2, and HepG2, among others.<br />\n&nbsp; o Each kit shall be capable of detecting multiple Modes-of-Action.<br />\n&bull; Each MultiFlow DNA Damage Kit shall contain all of the quality assured supplies and reagents to study multiple endpoints associated with DNA damage response pathways.<br />\n&nbsp; o Endpoints shall include p53 as an indicator of nuclear p53, &gamma;H2AX as a measure<br />\nof DNA double strand breaks, and phospho-histone H3 to label mitotic cells.<br />\n&bull; Kits shall arrive in multiple boxes due to the various temperature requirements (some on<br />\ndry ice, some on wet ice, and some at room temperature).<br />\n&bull; Kits shall be delivered in a single delivery to NCTR within 90 days of contract award<br />\nusing the required shipping method to ensure safe and proper arrival of item.</p>\n\n<p>Single Source Determination Based Upon:<br />\n&bull; The required kits have been used for more than 10years to assess the genotoxicity of<br />\nvarious chemicals or chemical mixtures in several protocols.<br />\n&bull; Litron Laboratories is the owner and manufacturer of the assay kits and is the only known<br />\nseller of the kits.<br />\n&bull; No additional sources have been identified as being capable of providing the required<br />\nkits.<br />\n&bull; Data generated from associated projects have been used to support other FDA Centers for<br />\nregulatory decision-making and published in peer-reviewed journals.<br />\n&bull; Competing this requirement would result in significant detrimental delays in fulfilling<br />\nAgency&rsquo;s requirement.<br />\n&bull; Acquisition of these kits are essential for the continuity of the data collection; past,<br />\npresent, and future.<br />\n&bull; A change in provider would compromise the integrity of future study and impact the<br />\nentire research program.<br />\n&bull; In an effort to maintain continuity and consistency, FDA/NCTR intends to purchase the<br />\nrequired kits from Litron Laboratories.</p>","origin":"detail"},"contacts":[{"name":"Howard Nesmith","role":"primary","email":"howard.nesmith@fda.hhs.gov","phone":"8705437459"}],"place_of_performance":{"zip":"72079","city":{"code":"34945","name":"Jefferson"},"state":{"code":"AR","name":"Arkansas"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"naics_codes":["325414"],"award":null,"attachments":[],"awards":[],"related":[{"key":"75F40126Q136817","latest_notice_id":"955053716c304fb9b9627b268abe4a42","title":"Service agreement on a Randox Daytona Plus Chemistry Analyzer Instrument","solicitation_number":"75F40126Q136817","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"811210","psc":"J066","set_aside":null,"state":"AR","county":"05069","county_name":"Jefferson County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"FDA2026136896","latest_notice_id":"2e4e031f692445cab046a32280d4215a","title":"Adverse Events Monitoring Systems (AEMS)","solicitation_number":"FDA-2026-136896","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-03T17:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":null,"psc":null,"set_aside":null,"state":"MD","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"75F40127R00002","latest_notice_id":"780583ad411042e2a84176f5a8d15163","title":"Preventative Maintenance of Above Standard Equipment (ASE) FDA National Capital Region","solicitation_number":"75F40127R00002","notice_type":"p","first_type":"p","first_posted":"2026-11-21","last_posted":"2026-11-21","notices":1,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"811210","psc":"J066","set_aside":"SBA","state":"MD","county":"24031","county_name":"Montgomery County","city":"2472450","city_name":"Silver Spring","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-22T05:17:48.835238Z"},{"key":"FDARFQ136450","latest_notice_id":"f5ae38bc3a004364b3e486c0f046d6dd","title":"JamF Software Licenses","solicitation_number":"FDA_RFQ_136450","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-07T18:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"513210","psc":"7A20","set_aside":"SBA","state":"MD","county":"24031","county_name":"Montgomery County","city":"2467675","city_name":"Rockville","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FDA27137158","latest_notice_id":"b3625b61a12d41bc93867c0d5ee840db","title":"NOTICE OF INTENT TO AWARD SOLE SOURCE FOR POLICE ORDERS","solicitation_number":"FDA-27-137158","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-07T22:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"922120","psc":"R499","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2467675","city_name":"Rockville","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open":[{"key":"SPE2DP26R0004","latest_notice_id":"a25be3e127094e7c9821b9a56b6d85ba","title":"Injectable Egg-Free Influenza Vaccine 2027","solicitation_number":"SPE2DP26R0004","notice_type":"o","first_type":"r","first_posted":"2026-08-24","last_posted":"2026-11-23","notices":4,"due_at":"2026-12-03T20:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE2DP","office_name":"DLA TROOP SUPPORT","naics":"325414","psc":"6505","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6505)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"SPE2DP26R0003","latest_notice_id":"7d2824e34a5e4120bfe59994ad6b58de","title":"Injectable Influenza Vaccine 2027","solicitation_number":"SPE2DP26R0003","notice_type":"o","first_type":"r","first_posted":"2026-08-24","last_posted":"2026-11-23","notices":4,"due_at":"2026-12-03T20:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE2DP","office_name":"DLA TROOP SUPPORT","naics":"325414","psc":"6505","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6505)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":2,"indexable":false}