{"canonical":"https://sealedbidder.com/opportunities/75d30126q79012","key":"75D30126Q79012","url":"https://sealedbidder.com/opportunities/75d30126q79012","title":"Pipette Calibration Systems","solicitation_number":"75D30126Q79012","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-07T12:00:00Z","first_posted":"2026-07-22","last_posted":"2026-07-22","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office":"CDC OFFICE OF ACQUISITION SERVICES","naics":"334515","psc":"H252","set_aside":null,"place_state":"GA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"13089","place_county_name":"DeKalb County","place_city":"1304000","place_city_name":"Atlanta","winner":"SARTORIUS CORPORATION","award_amount":null,"publications":[{"notice_id":"8ec28bdcc1b24654a386c3415fc7798e","title":"Pipette Calibration Systems","solicitation_number":"75D30126Q79012","notice_type":"p","base_type":"p","posted":"2026-07-22","posted_at":"2026-07-22T18:55:29.591Z","due_at":"2026-08-07T12:00:00Z","due_date":"2026-08-07","cancelled":false,"archived":true,"archive_date":"2026-08-22","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8ec28bdcc1b24654a386c3415fc7798e/view","enriched":true,"history":[{"index":3,"title":"Pipette Calibration Systems","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-22T18:55:29.591Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"8ec28bdcc1b24654a386c3415fc7798e","solicitation_number":"75D30126Q79012"}]}],"latest_notice_id":"8ec28bdcc1b24654a386c3415fc7798e","first_type":"p","notices":[{"dates":{"posted":"2026-07-22","posted_at":"2026-07-22T18:55:29.591Z","created_at":"2026-07-22T18:44:49.729Z","modified_at":"2026-08-22T05:06:37.264Z","response_deadline":{"raw":"2026-08-07T08:00:00-04:00","utc":"2026-08-07T12:00:00Z","date":"2026-08-07","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8ec28bdcc1b24654a386c3415fc7798e/view"},"naics":{"codes":["334515"],"primary":"334515"},"title":"Pipette Calibration Systems","agency":{"office":{"code":"75D301","name":"CDC OFFICE OF ACQUISITION SERVICES"},"subtier":{"code":"7523","name":"CENTERS FOR DISEASE CONTROL AND PREVENTION"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"30333","city":"ATLANTA","state":"GA","country":"USA"},"organization_id":"100188028","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-22","archive_type":"auto15"},"history":[{"index":3,"title":"Pipette Calibration Systems","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-22T18:55:29.591Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"8ec28bdcc1b24654a386c3415fc7798e","solicitation_number":"75D30126Q79012"}],"contacts":[{"name":"Cole Mullis","role":"primary","email":"ttu3@cdc.gov","phone":"7704881596"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"8ec28bdcc1b24654a386c3415fc7798e","lineage_id":"8ec28bdcc1b24654a386c3415fc7798e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-28T02:52:06.246396921Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"ff2c47076fe352be76b87ed9a096e27974452104e603743aed4fc34eba1cabe8","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-28T02:52:06.246396921Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>The program is requesting purchase of one SpeedCal Mobile multichannel pipette calibration system for the&nbsp;gravimetric testing of multichannel pipettes according to DIN EN ISO 8655 and one Cubis II single channel pipette&nbsp;calibration system with moisture trap, automated draft shield and proximity sensor. These items are manufactured by Sartorius Corporation.</p>\n\n<p>In order for NCIRD to achieve their mission, laboratory equipment must be compliant with either the Clinical&nbsp;Laboratory Improvement Amendments (CLIA) regulations or with the International Standards Organization (ISO)&nbsp;requirements. These regulations and standards require calibration and maintenance of laboratory equipment,&nbsp;including pipettes, to ensure the accuracy and reliability of test results and uphold quality control standards in&nbsp;clinical labs. This purchase is for two new calibration units that will be used for this purpose.<br />\nThere are two gold-standard approaches to checking the accuracy of a pipette&rsquo;s calibration&mdash;photometric, where the&nbsp;absorbance of a dye is measured to determine the volume actually delivered; and gravimetric, where distilled water&nbsp;is weighed to determine how much volume was delivered. The photometric method requires costly consumables in&nbsp;addition to equipment acquisition costs. In contrast, the gravimetric method only requires distilled water, and&nbsp;therefore the main associated cost is the equipment acquisition cost.</p>\n\n<p>When calibrating a large number of pipettes using the gravimetric method, it is optimal to use a balance designed for the purpose of pipette calibrations. This specially-designed balance integrates with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors from the redundancy of a repetitive task. The number of manufacturers of such systems is very limited.</p>\n\n<p>The Sartorius Cubis&reg; II MPS 116S single-channel pipette calibration balance and SpeedCal Mobile 12 multichannel pipette calibration system are specially designed for pipette calibration and integrate with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors.<br />\nWeb API &ndash; Both Sartorius systems use a web API to transfer data. A web API is a standardized way for different systems to talk to each other, regardless of who made them. In practical terms, this means data from the pipette calibration system can be sent directly into other lab systems without staff having to manually record, transform, or transfer results. Instead of relying on proprietary connections that only work within a single vendor&rsquo;s ecosystem, a web API uses open, widely accepted communication methods&mdash;similar to how websites interact over the internet&mdash;allowing systems from different&nbsp;manufacturers to work together seamlessly. This saves staff time, reduces transcription errors, improves data reliability, and enables integration across systems.<br />\nMultichannel calibration system with 12 independent load cells - Weighing distilled water is how pipette calibrations are performed gravimetrically. A load cell is the portion of a balance that weighs the water. Twelve independent load cells means the system can measure weights simultaneously (i.e. in parallel). This improves speed and reduces the impact of environmental changes and other sources of&nbsp;drift. The Sartorius system meets this requirement. Other systems have a single load cell and their systems can only measure the weights sequentially. This translates to both longer wait times while the system is measuring, and an increased impact of environmental changes, like the evaporation of water, which has a negative effect on pipette calibrations.<br />\nMobile-ready single channel and multichannel pipette calibration systems - The NCIRD team providing pipette calibration service does not have dedicated laboratory space at the Roybal campus. Instead, pipette calibrations are performed in the space owned by the requesting lab. Therefore the systems used must be designed for mobility.&nbsp;<br />\nAn equipment manufacturer with an established U.S presence and responsive technical support -<br />\nBoth the single channel and multichannel pipette calibration systems will be used to calibrate pipettes for NCIRD labs. When a pipette&rsquo;s calibration expires, it cannot be used to perform laboratory work. Timely recalibration is necessary to prevent disruptions to laboratory testing. If the system used to perform calibration is out of service, then pipettes cannot be recalibrated in a timely manner. A vendor&nbsp;with responsive, U.S.-based field service technicians is essential for continuity of NCIRD laboratory operations.<br />\n&nbsp;</p>\n\n<p>The technical requirements necessitating sole source for this procurement are as follows:</p>\n\n<p>1. API/Web Integration</p>\n\n<p>2. Mobility</p>\n\n<p>3. Multichannel calibration system with 12 independent load cells</p>\n\n<p>4. Established US customer support</p>","text":"The program is requesting purchase of one SpeedCal Mobile multichannel pipette calibration system for the gravimetric testing of multichannel pipettes according to DIN EN ISO 8655 and one Cubis II single channel pipette calibration system with moisture trap, automated draft shield and proximity sensor. These items are manufactured by Sartorius Corporation.\n\nIn order for NCIRD to achieve their mission, laboratory equipment must be compliant with either the Clinical Laboratory Improvement Amendments (CLIA) regulations or with the International Standards Organization (ISO) requirements. These regulations and standards require calibration and maintenance of laboratory equipment, including pipettes, to ensure the accuracy and reliability of test results and uphold quality control standards in clinical labs. This purchase is for two new calibration units that will be used for this purpose.\n\nThere are two gold-standard approaches to checking the accuracy of a pipette’s calibration—photometric, where the absorbance of a dye is measured to determine the volume actually delivered; and gravimetric, where distilled water is weighed to determine how much volume was delivered. The photometric method requires costly consumables in addition to equipment acquisition costs. In contrast, the gravimetric method only requires distilled water, and therefore the main associated cost is the equipment acquisition cost.\n\nWhen calibrating a large number of pipettes using the gravimetric method, it is optimal to use a balance designed for the purpose of pipette calibrations. This specially-designed balance integrates with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors from the redundancy of a repetitive task. The number of manufacturers of such systems is very limited.\n\nThe Sartorius Cubis® II MPS 116S single-channel pipette calibration balance and SpeedCal Mobile 12 multichannel pipette calibration system are specially designed for pipette calibration and integrate with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors.\n\nWeb API – Both Sartorius systems use a web API to transfer data. A web API is a standardized way for different systems to talk to each other, regardless of who made them. In practical terms, this means data from the pipette calibration system can be sent directly into other lab systems without staff having to manually record, transform, or transfer results. Instead of relying on proprietary connections that only work within a single vendor’s ecosystem, a web API uses open, widely accepted communication methods—similar to how websites interact over the internet—allowing systems from different manufacturers to work together seamlessly. This saves staff time, reduces transcription errors, improves data reliability, and enables integration across systems.\n\nMultichannel calibration system with 12 independent load cells - Weighing distilled water is how pipette calibrations are performed gravimetrically. A load cell is the portion of a balance that weighs the water. Twelve independent load cells means the system can measure weights simultaneously (i.e. in parallel). This improves speed and reduces the impact of environmental changes and other sources of drift. The Sartorius system meets this requirement. Other systems have a single load cell and their systems can only measure the weights sequentially. This translates to both longer wait times while the system is measuring, and an increased impact of environmental changes, like the evaporation of water, which has a negative effect on pipette calibrations.\n\nMobile-ready single channel and multichannel pipette calibration systems - The NCIRD team providing pipette calibration service does not have dedicated laboratory space at the Roybal campus. Instead, pipette calibrations are performed in the space owned by the requesting lab. Therefore the systems used must be designed for mobility.\n\nAn equipment manufacturer with an established U.S presence and responsive technical support -\n\nBoth the single channel and multichannel pipette calibration systems will be used to calibrate pipettes for NCIRD labs. When a pipette’s calibration expires, it cannot be used to perform laboratory work. Timely recalibration is necessary to prevent disruptions to laboratory testing. If the system used to perform calibration is out of service, then pipettes cannot be recalibrated in a timely manner. A vendor with responsive, U.S.-based field service technicians is essential for continuity of NCIRD laboratory operations.\n\nThe technical requirements necessitating sole source for this procurement are as follows:\n\n1. API/Web Integration\n\n2. Mobility\n\n3. Multichannel calibration system with 12 independent load cells\n\n4. Established US customer support","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"75D30126Q79012","place_of_performance":{"city":{"code":"2946","name":"Atlanta"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H252"}],"due_at":"2026-08-07T12:00:00Z","due_date":"2026-08-07","closes_at":"2026-08-07T12:00:00Z","awardable":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","state":"GA","county":"13089","county_name":"DeKalb County","city":"1304000","city_name":"Atlanta","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"Z867UMB3LJJ1","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-09-28T03:23:42.673067Z","principal_notice_id":"8ec28bdcc1b24654a386c3415fc7798e","description":{"text":"The program is requesting purchase of one SpeedCal Mobile multichannel pipette calibration system for the gravimetric testing of multichannel pipettes according to DIN EN ISO 8655 and one Cubis II single channel pipette calibration system with moisture trap, automated draft shield and proximity sensor. These items are manufactured by Sartorius Corporation.\n\nIn order for NCIRD to achieve their mission, laboratory equipment must be compliant with either the Clinical Laboratory Improvement Amendments (CLIA) regulations or with the International Standards Organization (ISO) requirements. These regulations and standards require calibration and maintenance of laboratory equipment, including pipettes, to ensure the accuracy and reliability of test results and uphold quality control standards in clinical labs. This purchase is for two new calibration units that will be used for this purpose.\n\nThere are two gold-standard approaches to checking the accuracy of a pipette’s calibration—photometric, where the absorbance of a dye is measured to determine the volume actually delivered; and gravimetric, where distilled water is weighed to determine how much volume was delivered. The photometric method requires costly consumables in addition to equipment acquisition costs. In contrast, the gravimetric method only requires distilled water, and therefore the main associated cost is the equipment acquisition cost.\n\nWhen calibrating a large number of pipettes using the gravimetric method, it is optimal to use a balance designed for the purpose of pipette calibrations. This specially-designed balance integrates with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors from the redundancy of a repetitive task. The number of manufacturers of such systems is very limited.\n\nThe Sartorius Cubis® II MPS 116S single-channel pipette calibration balance and SpeedCal Mobile 12 multichannel pipette calibration system are specially designed for pipette calibration and integrate with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors.\n\nWeb API – Both Sartorius systems use a web API to transfer data. A web API is a standardized way for different systems to talk to each other, regardless of who made them. In practical terms, this means data from the pipette calibration system can be sent directly into other lab systems without staff having to manually record, transform, or transfer results. Instead of relying on proprietary connections that only work within a single vendor’s ecosystem, a web API uses open, widely accepted communication methods—similar to how websites interact over the internet—allowing systems from different manufacturers to work together seamlessly. This saves staff time, reduces transcription errors, improves data reliability, and enables integration across systems.\n\nMultichannel calibration system with 12 independent load cells - Weighing distilled water is how pipette calibrations are performed gravimetrically. A load cell is the portion of a balance that weighs the water. Twelve independent load cells means the system can measure weights simultaneously (i.e. in parallel). This improves speed and reduces the impact of environmental changes and other sources of drift. The Sartorius system meets this requirement. Other systems have a single load cell and their systems can only measure the weights sequentially. This translates to both longer wait times while the system is measuring, and an increased impact of environmental changes, like the evaporation of water, which has a negative effect on pipette calibrations.\n\nMobile-ready single channel and multichannel pipette calibration systems - The NCIRD team providing pipette calibration service does not have dedicated laboratory space at the Roybal campus. Instead, pipette calibrations are performed in the space owned by the requesting lab. Therefore the systems used must be designed for mobility.\n\nAn equipment manufacturer with an established U.S presence and responsive technical support -\n\nBoth the single channel and multichannel pipette calibration systems will be used to calibrate pipettes for NCIRD labs. When a pipette’s calibration expires, it cannot be used to perform laboratory work. Timely recalibration is necessary to prevent disruptions to laboratory testing. If the system used to perform calibration is out of service, then pipettes cannot be recalibrated in a timely manner. A vendor with responsive, U.S.-based field service technicians is essential for continuity of NCIRD laboratory operations.\n\nThe technical requirements necessitating sole source for this procurement are as follows:\n\n1. API/Web Integration\n\n2. Mobility\n\n3. Multichannel calibration system with 12 independent load cells\n\n4. Established US customer support","html":"<p>The program is requesting purchase of one SpeedCal Mobile multichannel pipette calibration system for the&nbsp;gravimetric testing of multichannel pipettes according to DIN EN ISO 8655 and one Cubis II single channel pipette&nbsp;calibration system with moisture trap, automated draft shield and proximity sensor. These items are manufactured by Sartorius Corporation.</p>\n\n<p>In order for NCIRD to achieve their mission, laboratory equipment must be compliant with either the Clinical&nbsp;Laboratory Improvement Amendments (CLIA) regulations or with the International Standards Organization (ISO)&nbsp;requirements. These regulations and standards require calibration and maintenance of laboratory equipment,&nbsp;including pipettes, to ensure the accuracy and reliability of test results and uphold quality control standards in&nbsp;clinical labs. This purchase is for two new calibration units that will be used for this purpose.<br />\nThere are two gold-standard approaches to checking the accuracy of a pipette&rsquo;s calibration&mdash;photometric, where the&nbsp;absorbance of a dye is measured to determine the volume actually delivered; and gravimetric, where distilled water&nbsp;is weighed to determine how much volume was delivered. The photometric method requires costly consumables in&nbsp;addition to equipment acquisition costs. In contrast, the gravimetric method only requires distilled water, and&nbsp;therefore the main associated cost is the equipment acquisition cost.</p>\n\n<p>When calibrating a large number of pipettes using the gravimetric method, it is optimal to use a balance designed for the purpose of pipette calibrations. This specially-designed balance integrates with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors from the redundancy of a repetitive task. The number of manufacturers of such systems is very limited.</p>\n\n<p>The Sartorius Cubis&reg; II MPS 116S single-channel pipette calibration balance and SpeedCal Mobile 12 multichannel pipette calibration system are specially designed for pipette calibration and integrate with software to automatically capture the data (reducing transcription errors), and tares for the next reading to save the operator time and reduce errors.<br />\nWeb API &ndash; Both Sartorius systems use a web API to transfer data. A web API is a standardized way for different systems to talk to each other, regardless of who made them. In practical terms, this means data from the pipette calibration system can be sent directly into other lab systems without staff having to manually record, transform, or transfer results. Instead of relying on proprietary connections that only work within a single vendor&rsquo;s ecosystem, a web API uses open, widely accepted communication methods&mdash;similar to how websites interact over the internet&mdash;allowing systems from different&nbsp;manufacturers to work together seamlessly. This saves staff time, reduces transcription errors, improves data reliability, and enables integration across systems.<br />\nMultichannel calibration system with 12 independent load cells - Weighing distilled water is how pipette calibrations are performed gravimetrically. A load cell is the portion of a balance that weighs the water. Twelve independent load cells means the system can measure weights simultaneously (i.e. in parallel). This improves speed and reduces the impact of environmental changes and other sources of&nbsp;drift. The Sartorius system meets this requirement. Other systems have a single load cell and their systems can only measure the weights sequentially. This translates to both longer wait times while the system is measuring, and an increased impact of environmental changes, like the evaporation of water, which has a negative effect on pipette calibrations.<br />\nMobile-ready single channel and multichannel pipette calibration systems - The NCIRD team providing pipette calibration service does not have dedicated laboratory space at the Roybal campus. Instead, pipette calibrations are performed in the space owned by the requesting lab. Therefore the systems used must be designed for mobility.&nbsp;<br />\nAn equipment manufacturer with an established U.S presence and responsive technical support -<br />\nBoth the single channel and multichannel pipette calibration systems will be used to calibrate pipettes for NCIRD labs. When a pipette&rsquo;s calibration expires, it cannot be used to perform laboratory work. Timely recalibration is necessary to prevent disruptions to laboratory testing. If the system used to perform calibration is out of service, then pipettes cannot be recalibrated in a timely manner. A vendor&nbsp;with responsive, U.S.-based field service technicians is essential for continuity of NCIRD laboratory operations.<br />\n&nbsp;</p>\n\n<p>The technical requirements necessitating sole source for this procurement are as follows:</p>\n\n<p>1. API/Web Integration</p>\n\n<p>2. Mobility</p>\n\n<p>3. Multichannel calibration system with 12 independent load cells</p>\n\n<p>4. Established US customer support</p>","origin":"detail"},"contacts":[{"name":"Cole Mullis","role":"primary","email":"ttu3@cdc.gov","phone":"7704881596"}],"place_of_performance":{"city":{"code":"2946","name":"Atlanta"},"state":{"code":"GA","name":"Georgia"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"30333","city":"ATLANTA","state":"GA","country":"USA"},"naics_codes":["334515"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_75D30126P21137_7523_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_75D30126P21137_7523_-NONE-_-NONE-/","piid":"75D30126P21137","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"Z867UMB3LJJ1","recipient_name":"SARTORIUS CORPORATION","recipient_uei":"Z867UMB3LJJ1","recipient_cage":"0DNR2","recipient_city":"BOHEMIA","recipient_state":"NY","sub_name":"Centers for Disease Control and Prevention","office_name":"CDC OFFICE OF ACQUISITION SERVICES","office_key":"o-75D301","first_action_date":"2026-08-11","last_action_date":"2026-08-11","actions":1,"obligated":"172891.25","current_total_value":"172891.25","potential_total_value":"172891.25","naics":"334515","psc":"6640","extent_competed":"NOT COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":1,"description":"PIPETTE CALIBRATION SYSTEMS EO 14398","method":"solicitation","confidence":"high","evidence":["solicitation number 75D30126Q79012 equals the FPDS solicitation identifier","same awarding office 75D301"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"SSDS1142026NCIRDID","latest_notice_id":"71915a7ca3cf474c99e2c11a87b00e75","title":"A Virtual Network to Investigate the Clinical Epidemiology of Influenza and the Effectiveness of Influenza Vaccines","solicitation_number":"SSDS-11-4-2026-NCIRD-ID","notice_type":"r","first_type":"r","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"541380","psc":"Q301","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"A VIRTUAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"63EB121AF73647EFAC9EFE2A407DA85F","latest_notice_id":"63eb121af73647efac9efe2a407da85f","title":"MSHA Approved Portable, Inflatable Refuge Alternative","solicitation_number":"00879","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-04T20:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"333131","psc":"4240","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"B8164D58E343480FAF72E235E2A2B7BA","latest_notice_id":"b8164d58e343480faf72e235e2a2b7ba","title":"Notice of Intent to Sole Source - Rigaku Americas Holding, Inc","solicitation_number":"00844","notice_type":"p","first_type":"p","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-12-08T21:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"811210","psc":"J066","set_aside":null,"state":"PA","county":"42003","county_name":"Allegheny County","city":"4261000","city_name":"Pittsburgh","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"4BADF0FAA275492A8898366F3CFCB4F9","latest_notice_id":"4badf0faa275492a8898366f3cfcb4f9","title":"Notice of Intent to Sole Source - SmartLab X-ray Diffractometer (XRD) Service Agreement - Rigaku Americas Holding, Inc","solicitation_number":"00844","notice_type":"p","first_type":"p","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T21:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"811210","psc":"J066","set_aside":null,"state":"PA","county":"42003","county_name":"Allegheny County","city":"4261000","city_name":"Pittsburgh","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"202695987","latest_notice_id":"a777b0e867174da0a855e8ed547719c9","title":"Notice of Intent to Sole Source a Thermo Orbitrap Fusion Lumos and Thermo RSLCnano UPLC Maintenance Agreement","solicitation_number":"2026-95987","notice_type":"p","first_type":"p","first_posted":"2025-12-09","last_posted":"2025-12-09","notices":1,"due_at":"2026-12-24T21:00:00Z","due_date":"2026-12-24","closes_at":"2026-12-24T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7523","sub_name":"CENTERS FOR DISEASE CONTROL AND PREVENTION","office_key":"o-75D301","office_name":"CDC OFFICE OF ACQUISITION SERVICES","naics":"811210","psc":"J066","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open":[{"key":"SPRHA426R0388","latest_notice_id":"60856cddebe74c5bbad8d9f34c209a77","title":"Transducer","solicitation_number":"SPRHA4-26-R-0388","notice_type":"o","first_type":"p","first_posted":"2026-05-14","last_posted":"2026-11-17","notices":4,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPRHA4","office_name":"DLA AVIATION AT OGDEN, UT","naics":"334515","psc":"6695","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6695)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N6833526RFPREQBL310000026","latest_notice_id":"238ef98fbffe40dcb3f4c0cecc2f707e","title":"Request for Information Authorized Distributors/Resellers of Keysight Technologies Products","solicitation_number":"N68335-26-RFPREQ-BL31000-0026","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-26T22:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N68335","office_name":"NAVAIR WARFARE CTR AIRCRAFT DIV","naics":"334515","psc":"6625","set_aside":null,"state":"MS","county":"28047","county_name":"Harrison County","city":"2829700","city_name":"Gulfport","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-11T05:50:21.226923Z"},{"key":"N0010426QNF12","latest_notice_id":"6983ef64eae84b6789638a6497ae12c9","title":"SERVER,AUTOMATIC DA","solicitation_number":"N0010426QNF12","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-10-21","notices":3,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"334515","psc":"7E20","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7E20)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"}],"similar_open_total":41,"indexable":false}