Solicitation
Component Repair and Calibration
75301-26-Q-79276
Centers for Disease Control and Prevention, CDC Office of Acquisition Services. Electronic and Precision Equipment Repair and Maintenance.
Response deadline
September 21, 2026 at 10:00 AM EDT
Closed 65 days ago. Posted September 17, 2026, first published September 17, 2026. Scheduled to archive September 21, 2026.
Get the next one like this from Centers for Disease Control and Prevention by email, the day it is posted.Find my opportunities
This one closed in 2026
63 like it are open now in electronic and precision equipment repair and maintenance
- Repair/Overhaul of Flat Panel Up Front Controller (FPUFC)
Department of the Air Force, FA8538 AFSC Pzaab
SolicitationNAICS 811210Warner Robins, GAFA853826R0017Due todayNov 25 - Sole Source to United Electronic Industries Inc for Long Term Channel CAMS Single Board Computer Control Alarm and Monitor Systems Unit Evaluation and Repair Services Per Attachments
Department of the Navy, Naval Surface Warfare Center
Combined synopsis and solicitationNAICS 811210Panama City Beach, FLN61331-27-Q-JK06Due todayNov 25 - Neptune Rover Medical Surgical Maintenance Base plus Four (4) Option Years
Department of Veterans Affairs, 248-Network Contract Office 8
SolicitationNAICS 811210Bay Pines, FL36C24827Q0051Due todayNov 25
All 63 open in electronic and precision equipment repair and maintenance
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Solicitation. A formal request for proposals, quotes or bids. Offers are due by the response deadline. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 811210 (electronic and precision equipment repair and maintenance), means no more than $34 million in average annual receipts, counted with affiliates. What a set-aside is
- Time to respond
- Bidders had 4 days from the day the solicitation was posted, September 17, 2026, to the deadline.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Notice of Intent
The Centers for Disease Control and Prevention intends to award a sole source firm fixed price
purchase order to TSI Incorporated 500 Cardigan Road Shoreview, MN 55126 (CAGE Code:
24575) for the purchase of repair and calibration services for Government owned equipment.
Only the manufacturer (TSI Inc.) can repair and calibrate the Aerodynamic Particle Sizer because
proprietary models must be adjusted for the calibration, proprietary knowledge of internal flow
regulators is needed for the repair, and unique access to instrument components that are located
behind embedded electronics is required. Alternative service providers are not available because
proprietary information on the instrument operating model and flow regulation system is
required.
Description
TCI shall repair and calibrate 3 Aerodynamic Particle Sizers with an expected turnaround of 21
days. Upon receipt of instruments, TSI Inc. shall bring the 3 Aerodynamic Particle Sizers to a
calibration flow rate of 5 liters per minute (lpm) (1 lpm for sample + 4 lpm for sheath) and
maintain the calibration flow rate, even with a pressure drop of up to 50 inH20 at the inlet by
adjusting microprocessor controlled volumetric flow control, barometric pressure correction, and
separate pumps for sheath and total flows, to enable the Aerodynamic Particle Sizers to operate
under a wide range of conditions and still maintain calibration.
TSI Inc. shall also calibrate the 3 Aerodynamic Particle sizers for precise and accurate numbersize
distributions for 0.37 to 20 micrometers aerodynamic diameter using a time-of-flight
technique, and a patented, double-crest optical system to detect the occurrence of particle
coincidence (when more than one particle is in the detection area) and to identify poor signals
near the instrument’s lower detection threshold. The Government will provide the following
components for repair and calibration:
1. Aerodynamic Particle Sizer-S/N 1169
2. Aerodynamic Particle Sizer-S/N 1203
3. Aerodynamic Particle Sizer-S/N 72321006
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- Notice of Intent.pdf20 KB, September 17, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
September 17, 2026
Solicitation
Due September 21, 2026 at 10:00 AM EDT. SAM.gov, notice 083c6e2cc5164aeeba27305905a52a30
2 revisions on SAM
- September 17, 2026: publish, solicitation
- September 17, 2026: publish, solicitation
September 17, 2026
Solicitation
Due September 21, 2026 at 10:00 AM EDT. SAM.gov, notice 9eb57fd9e4e34da6bccc5f72bd6c556e
2 revisions on SAM
- September 17, 2026: publish, solicitation
- September 17, 2026: publish, solicitation
Points of contact
- Sandra Adamsab41@cdc.gov7704885543