{"canonical":"https://sealedbidder.com/opportunities/70zh1526qcga00009","key":"70ZH1526QCGA00009","url":"https://sealedbidder.com/opportunities/70zh1526qcga00009","title":"Inspect and Repair of 13.2KV Main Switchgear","solicitation_number":"70ZH1526QCGA00009","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-11-12T13:00:00Z","first_posted":"2026-10-30","last_posted":"2026-11-05","department":"HOMELAND SECURITY, DEPARTMENT OF","subagency":"US COAST GUARD","office":"USCG ACADEMY","naics":"238210","psc":"J061","set_aside":"SBA","place_state":"CT","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"09180","place_county_name":"Southeastern Connecticut Planning Region","place_city":"0952280","place_city_name":"New London","winner":null,"award_amount":null,"publications":[{"notice_id":"fe4d282a81414b2ba27f32e30140b0fa","title":"Inspect and Repair of 13.2KV Main Switchgear","solicitation_number":"70ZH1526QCGA00009","notice_type":"k","base_type":"k","posted":"2026-10-30","posted_at":"2026-10-30T15:20:45.433Z","due_at":"2026-11-12T13:00:00Z","due_date":"2026-11-12","cancelled":false,"archived":false,"archive_date":"2026-11-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fe4d282a81414b2ba27f32e30140b0fa/view","enriched":true,"history":[{"index":1,"title":"Inspect and Repair of 13.2KV Main Switchgear","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T15:20:45.433Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"fe4d282a81414b2ba27f32e30140b0fa","solicitation_number":"70ZH1526QCGA00009"}]},{"notice_id":"74ff5bb933da4d4ea11b225bd7b96b82","title":"Inspect and Repair of 13.2KV Main Switchgear","solicitation_number":"70ZH1526QCGA00009","notice_type":"k","base_type":"k","posted":"2026-11-05","posted_at":"2026-11-06T00:24:46.229Z","due_at":"2026-11-12T13:00:00Z","due_date":"2026-11-12","cancelled":false,"archived":false,"archive_date":"2026-11-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/74ff5bb933da4d4ea11b225bd7b96b82/view","enriched":true,"history":[{"index":2,"title":"Inspect and Repair of 13.2KV Main Switchgear","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T00:24:46.229Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"74ff5bb933da4d4ea11b225bd7b96b82","solicitation_number":"70ZH1526QCGA00009","parent_opportunity_id":"fe4d282a81414b2ba27f32e30140b0fa"},{"index":1,"title":"Inspect and Repair of 13.2KV Main Switchgear","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T15:20:45.433Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"fe4d282a81414b2ba27f32e30140b0fa","solicitation_number":"70ZH1526QCGA00009"}]}],"latest_notice_id":"74ff5bb933da4d4ea11b225bd7b96b82","first_type":"k","notices":[{"dates":{"posted":"2026-10-30","posted_at":"2026-10-30T15:20:45.433Z","created_at":"2026-10-30T15:17:51.788Z","modified_at":"2026-10-30T15:20:45.438Z","response_deadline":{"raw":"2026-11-12T08:00:00-05:00","utc":"2026-11-12T13:00:00Z","date":"2026-11-12","time":"08:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fe4d282a81414b2ba27f32e30140b0fa/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Inspect and Repair of 13.2KV Main Switchgear","agency":{"office":{"code":"70ZH15","name":"USCG ACADEMY"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"06320","city":"New London","state":"CT","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-27","archive_type":"auto15"},"history":[{"index":1,"title":"Inspect and Repair of 13.2KV Main Switchgear","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T15:20:45.433Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"fe4d282a81414b2ba27f32e30140b0fa","solicitation_number":"70ZH1526QCGA00009"}],"contacts":[{"name":"Jerome Manuel","role":"primary","email":"Jerome.R.Manuel@uscg.mil"},{"name":"CDR Avery Weston","role":"secondary","email":"Avery.L.Weston@uscg.mil","phone":"(787) 729-2339"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"fe4d282a81414b2ba27f32e30140b0fa","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"fe4d282a81414b2ba27f32e30140b0fa","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-31T04:19:49.679408882Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"1735de0b5e774e4b75efe1dc9e3810dc7a404588d2e6fdb21fd0bea5e3fc6dc7","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-31T03:47:30.063427912Z"},"description":{"html":"<p>The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.</p>","text":"The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70ZH1526QCGA00009","place_of_performance":{"zip":"06320","city":{"code":"52280","name":"New London"},"state":{"code":"CT","name":"Connecticut"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J061"},{"dates":{"posted":"2026-11-05","posted_at":"2026-11-06T00:24:46.229Z","created_at":"2026-11-05T19:09:07.970Z","modified_at":"2026-11-06T00:24:46.237Z","response_deadline":{"raw":"2026-11-12T08:00:00-05:00","utc":"2026-11-12T13:00:00Z","date":"2026-11-12","time":"08:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/74ff5bb933da4d4ea11b225bd7b96b82/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Inspect and Repair of 13.2KV Main Switchgear","agency":{"office":{"code":"70ZH15","name":"USCG ACADEMY"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"06320","city":"New London","state":"CT","country":"USA"},"organization_id":"500211731","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-27","archive_type":"auto15"},"history":[{"index":2,"title":"Inspect and Repair of 13.2KV Main Switchgear","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T00:24:46.229Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"74ff5bb933da4d4ea11b225bd7b96b82","solicitation_number":"70ZH1526QCGA00009","parent_opportunity_id":"fe4d282a81414b2ba27f32e30140b0fa"},{"index":1,"title":"Inspect and Repair of 13.2KV Main Switchgear","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T15:20:45.433Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"fe4d282a81414b2ba27f32e30140b0fa","solicitation_number":"70ZH1526QCGA00009"}],"contacts":[{"name":"Jerome Manuel","role":"primary","email":"Jerome.R.Manuel@uscg.mil"},{"name":"CDR Avery Weston","role":"secondary","email":"Avery.L.Weston@uscg.mil","phone":"(787) 729-2339"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"74ff5bb933da4d4ea11b225bd7b96b82","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"fe4d282a81414b2ba27f32e30140b0fa","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T09:45:13.510884260Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"d24fffa745785facb71786d3b9637d8d5f72b746ef533f2bd05ded911182c599","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-11T09:45:13.510884260Z","first_seen_at":"2026-11-06T04:42:59.950874882Z"},"description":{"html":"<p>The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.</p>","text":"The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70ZH1526QCGA00009","place_of_performance":{"zip":"06320","city":{"code":"52280","name":"New London"},"state":{"code":"CT","name":"Connecticut"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J061"}],"due_at":"2026-11-12T13:00:00Z","due_date":"2026-11-12","closes_at":"2026-11-12T13:00:00Z","awardable":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZH15","office_name":"USCG ACADEMY","state":"CT","county":"09180","county_name":"Southeastern Connecticut Planning Region","city":"0952280","city_name":"New London","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-06T04:46:59.158685Z","principal_notice_id":"74ff5bb933da4d4ea11b225bd7b96b82","description":{"text":"The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.","html":"<p>The U.S. Coast Guard Academy requires a qualified, licensed electrical contractor to inspect, repair as necessary, test, and restore Eaton/Cutler-Hammer MVS2 13.2 kV medium-voltage load interrupter switchgear, with primary work focused on Cabinet 5 and the associated 15 kV feeder cable serving Smith Hall. The contractor shall inspect Cabinet 5 for damage or missing/cannibalized components; remove and replace three Eaton 15CLE-250E fuses; procure and deliver three additional matching fuses for on-site spares; perform insulation-resistance testing of the feeder cable in accordance with current ANSI/NETA standards; provide certified test and field-service reports; coordinate all required outages and lockout/tagout procedures with the Government; and safely re-energize the cabinet and feeder upon successful completion of repairs and testing. All work shall comply with applicable OSHA, NFPA 70E, federal, state, and local requirements, including proper licensed personnel, arc-flash personal protective equipment, site protection, cleanup, and disposal of waste materials.</p>","origin":"detail"},"contacts":[{"name":"Jerome Manuel","role":"primary","email":"Jerome.R.Manuel@uscg.mil"},{"name":"CDR Avery Weston","role":"secondary","email":"Avery.L.Weston@uscg.mil","phone":"(787) 729-2339"}],"place_of_performance":{"zip":"06320","city":{"code":"52280","name":"New London"},"state":{"code":"CT","name":"Connecticut"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"06320","city":"New London","state":"CT","country":"USA"},"naics_codes":["238210"],"award":null,"attachments":[{"resource_id":"4d07a0f7ddc14e1684b766114cec831a","name":"Combined Synopsis Solicitation CGC Switchgear FY27.pdf","kind":"file","mime_type":".pdf","size_bytes":265135,"posted_at":"2026-10-30T15:20:45.433Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4d07a0f7ddc14e1684b766114cec831a/download","mirrored":false},{"resource_id":"26b92960c4c54b999b1e4b205c2e3ec8","name":"SOW Inspect and Repair Main Switchgear at CGA.pdf","kind":"file","mime_type":".pdf","size_bytes":1268530,"posted_at":"2026-10-30T15:20:45.433Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/26b92960c4c54b999b1e4b205c2e3ec8/download","mirrored":false},{"resource_id":"877e54cc0fa049af90126703f01ccad7","name":"SwithGear QA CGA Response 5NOV26.pdf","kind":"file","mime_type":".pdf","size_bytes":65715,"posted_at":"2026-11-06T00:24:46.229Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/877e54cc0fa049af90126703f01ccad7/download","mirrored":false}],"awards":[],"related":[{"key":"70ZH1526QCGA00004","latest_notice_id":"8ade577b9ab54cb5a3eef8a224904738","title":"Floor Refinishing Services","solicitation_number":"70ZH1526QCGA00004","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-15T14:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZH15","office_name":"USCG ACADEMY","naics":"238330","psc":"S299","set_aside":"SBA","state":"CT","county":"09180","county_name":"Southeastern Connecticut Planning Region","city":"0952280","city_name":"New London","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"127EAW27Q0002","latest_notice_id":"59c24c6aad3541448f35b465324ba88b","title":"Forest Service - Solar Batteries Frenchman Work Center","solicitation_number":"127EAW27Q0002","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-28T00:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-127EAW","office_name":"USDA-FS, CSA SOUTHWEST 6","naics":"238210","psc":"N061","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"FA706027R0001","latest_notice_id":"541189d6ec7b40e2b7a0dcf9030d56ec","title":"Request for Information/Market Intelligence Notice: Repair Electrical Distribution System Switchgear Stations & Addition of Redundancy Cable Use of Progressive Design Build (PDB) with Other Transaction Authority (OTA)","solicitation_number":"FA706027R0001","notice_type":"r","first_type":"r","first_posted":"2026-10-23","last_posted":"2026-10-23","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA7060","office_name":"FA7060 11TH CONTRACTING SQ PK","naics":"238210","psc":"Z2JZ","set_aside":null,"state":"DC","county":"11001","county_name":"District of Columbia","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-24T03:56:54.139438Z"}],"similar_open_total":40,"indexable":true}