{"canonical":"https://sealedbidder.com/opportunities/70z085q12971","key":"70Z085Q12971","url":"https://sealedbidder.com/opportunities/70z085q12971","title":"USCGC ALEX HALEY","solicitation_number":"70Z085Q12971","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-05-05T15:00:00Z","first_posted":"2025-04-25","last_posted":"2025-04-25","department":"HOMELAND SECURITY, DEPARTMENT OF","subagency":"US COAST GUARD","office":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"336611","psc":"J020","set_aside":"SBA","place_state":"AK","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"02150","place_county_name":"Kodiak Island Borough","place_city":"0240950","place_city_name":"Kodiak","winner":null,"award_amount":null,"publications":[{"notice_id":"131f6567affe45f49cd116bfdf6c8722","title":"USCGC ALEX HALEY","solicitation_number":"70Z085Q12971","notice_type":"k","base_type":"k","posted":"2025-04-25","posted_at":"2025-04-25T20:30:33.859Z","due_at":"2025-05-05T15:00:00Z","due_date":"2025-05-05","cancelled":false,"archived":true,"archive_date":"2025-05-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/131f6567affe45f49cd116bfdf6c8722/view","enriched":true,"history":[{"index":3,"title":"USCGC ALEX HALEY","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-25T20:30:33.859Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"131f6567affe45f49cd116bfdf6c8722","solicitation_number":"70Z085Q12971"}]}],"latest_notice_id":"131f6567affe45f49cd116bfdf6c8722","first_type":"k","notices":[{"dates":{"posted":"2025-04-25","posted_at":"2025-04-25T20:30:33.859Z","created_at":"2025-04-25T20:23:29.146Z","modified_at":"2025-05-06T04:00:10.294Z","response_deadline":{"raw":"2025-05-05T08:00:00-07:00","utc":"2025-05-05T15:00:00Z","date":"2025-05-05","time":"08:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/131f6567affe45f49cd116bfdf6c8722/view"},"naics":{"codes":["336611"],"primary":"336611"},"title":"USCGC ALEX HALEY","agency":{"office":{"code":"70Z085","name":"SFLC PROCUREMENT BRANCH 2(00085)"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"organization_id":"100187922","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-05-05","archive_type":"auto_custom"},"history":[{"index":3,"title":"USCGC ALEX HALEY","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-25T20:30:33.859Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"131f6567affe45f49cd116bfdf6c8722","solicitation_number":"70Z085Q12971"}],"contacts":[{"name":"BRENDEN COX","role":"primary","email":"BRENDEN.S.COX@USCG.MIL","phone":"12068315347"},{"name":"Isaiah C. Ragan","role":"secondary","email":"isaiah.c.ragan@uscg.mil","phone":"5104375429"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"131f6567affe45f49cd116bfdf6c8722","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"131f6567affe45f49cd116bfdf6c8722","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-16T03:21:52.669508083Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"f947ebc5023b774b0833068f5a49f2f6833cedd0528ec8e73044ec6ee416c0b8","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-16T03:21:52.669508083Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>TECHNICAL SERVICES<br />\nUSCGC ALEX HALEY (WMEC-282) - Z12204<br />\nEVALUATION AND REPAIR FAN UNIT(S)<br />\n1. Objective. The objective of this document sets forth the receipt, disassembly, inspections,<br />\ncondition/test reports, overhaul/repair, reassembly, testing, preservation, packaging, packing, and<br />\nmarking of Navy standard fan unit(s) used on the U.S. Coast Guard Cutter ALEX HALEY.<br />\n2. References. For any listed references to be distributed, the contractor must be registered in the Joint<br />\nCertification Program (JCP) through Defense Logistics Agency (DLA) and provide your JCP number<br />\nand expiration date to the listed point of contact (POC) for this work.<br />\n2 .1. Specification Order of Precedence. In the event of a conflict between the text of this specification<br />\nand the references cited herein, the text of this specification shall take precedence. Nothing in this<br />\nspecification, however, supersedes applicable laws and regulations unless a specific ex emption<br />\nhas been obtained.<br />\n2.2. Government Documents. The following specifications and standards form a part of this<br />\nspecification to the extent specified herein. Unless otherwise specified, the documents listed here<br />\nby number and date shall be those in the current Department of Defense Single Stock Point of<br />\nSpecification and Standards (DODSSP) and supplements thereto.<br />\n2.2.1.Naval Ships Technical Manual (NSTM), S9512-A3-MMA-010, Chapter 512, Fan,<br />\nVaneaxial and Tubeaxial, 1987<br />\n2.2.2.Federal Standard, FED-STD-595C, dated 07/31/2008, Colors Used in Government<br />\nProcurement<br />\n2.3. United States Coast Guard Drawings and Publications. The following specifications and<br />\nstandards form a part of this specification to the extent specified herein.<br />\n2.3.1.United States Coast Guard Commandant Instruction (COMDTINST) M10360.3 (series),<br />\nCoatings and Color Manual<br />\n2.3.2.United States Coast Guard Technical Manual TP: 7148-512-A, dated08/24/2007, Standard<br />\nXA Vaneaxial Fan<br />\n2.3.3.Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022,<br />\nGeneral Requirements<br />\n2.3.4.Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3020), 2022,<br />\nOverhaul AC Electrical Motors<br />\n2.3.5.Specification Packaging and Labeling SP-PP&amp;M Rev D dated 6/6/11<br />\n2.4. Commercial Documents. The following documents form a part of this specification to the extent<br />\nspecified herein. The documents shall be the version listed by number and date from the<br />\nreferenced industry organization. Commercial documents may be listed in the Department of<br />\nDefense Index of Specifications and Standards (DODISS).<br />\n2.4.1.American Society for Testing &amp; Materials (ASTM) D3951-98, dated 2004, Standard<br />\nPractice for Commercial Packaging<br />\n2.4.2.International Standard Organization (ISO) 2953, 1999, Mechanical Vibration, Balancing<br />\nMachines, Description and Evaluation<br />\n2.4.3.Steel Structure Painting Council, SSPC-SP 3, dated 11/01/1982, Power Tool Cleaning<br />\n3. Background. This requirement is for the contractor to evaluate and repair the ventilation fan(s)<br />\n(vaneaxial) listed below Table 1 and Section 5. The fan units are designated as Supply Fan 1-22-2 and<br />\nSupply Fan 2-40-1.Table 1 - Ventilation Fan(s) for Overhaul<br />\nSystem / Fan Number Model Number Location<br />\nApproximate<br />\nDimensions/Weight<br />\nSl-22-2<br />\nAl-1/2 Class Z, 1,799<br />\nDry Stores (1-23-0-A)<br />\n20&quot; long x 17 .5&quot;<br />\nCFM 1.25 HP Diameter / 160 lbs.<br />\nS2-40-1 Al-1/2 Class Z, 1,450 Salvage Storeroom #4 20&quot; long x 17 .5&quot;<br />\nCFM 1.25 HP (2-36-0-A) Diameter / 160 lbs.<br />\n4. Tasks. The contractor shall provide services of which includes but may not limited to:<br />\n4.1. General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and<br />\nin this item, as applicable, during the performance of this availability. The requirements of this<br />\nwork apply to all work under the scope of this contract, whether explicitly stated in all following<br />\nwork items or not, and to all other work subsequently authorized by changes, modifications, or<br />\nextensions to the contract.<br />\n4.2. The Contractor shall submit a Receiving Inspection Report to the Coast Guard Contracting<br />\nOfficer (KO), Contracting Office&#39;s Representative (COR), and other listed Points of Contacts<br />\n(POCs) within 2 days of receiving the government furnished property (GFP). The report shall<br />\ndocument the make, part number, and/or model. This report shall also include digital<br />\nphotographic documentation of the crate and its contents.<br />\n4.2.1.It is assumed that the fan unit(s) will arrive in a re-usable container. In the event the<br />\ncontainer is deemed unusable the contractor shall state so as part of the inspection report and<br />\nprovide photo documentation.<br />\n4.3. Inspections, repair/overhaul and testing of the fan unit(s) shall be accomplished in accordance<br />\nwith the OEM procedures, specifications, references, and standard practices. The Contractor shall<br />\nconform to all requirements specified throughout this specification during performance of this<br />\ncontract. In the event of a conflict between the text of this specification and the references cited<br />\nherein, the text of this specification takes precedence. Nothing in this specification; however,<br />\nsupersedes applicable laws and regulations unless a specific exemption has been obtained.<br />\n4.3.1.The overhaul requirements described herein are considered the minimumnecessary and are<br />\nnot intended to replace any procedures, controls, examinations, or tests normally employed<br />\nby the Contractor to assure the quality of the product.<br />\n4 .3 .2. The overhaul of the fan unit( s) is intended to return the unit&#39;s performance and appearance<br />\nto a condition capable of functioning and performing in the same manner as an identical new<br />\nunit, as referred to as serviceable &quot;A&quot; condition.<br />\n4.4. Condition Found Report (CFR).<br />\n4.4.1.Preliminary disassembly and inspection of each fan unit shall be conducted in accordance<br />\nwith OEM procedures, specifications, references, and standard practices to determine the<br />\ntotal estimated cost to repair, including material, labor, testing, Preservation, Packing and<br />\nMarking (PP&amp;M) costs. A CFR shall be submitted to the KO, COR, and other listed POCs<br />\nwithin 5 days of the completion of the Receiving Inspection Report detailing the repair parts<br />\nrecommended for replacement and a total repair cost.<br />\n4.4.2. The CFR shall be submitted to the KO, COR, and other listed POCs for review and approval<br />\nprior to the start of any repair or order of any material. The Contractor shall also provide the<br />\nreplacement cost of an identical new fan unit for comparison to the overhaul cost. At a<br />\nminimum, mandatory replacement parts shall include all bearings, bushings, seals and<br />\ngaskets. All parts that are worn, have an improper fit and or damaged beyond the OEM<br />\ntolerances, shall be repaired or replaced as determined by the Contractor.<br />\n4.4.3.The detailed cost estimate shall contain the following as a minimum: the part number, NSN<br />\nand serial number of the fan unit, the contract number and deliveiy order number for the fan<br />\nunit, a listing of individual parts by part number, cost and quantity, a listing of labor hoursand labor rate to perform the overhaul, testing, and packaging, the cost of an identical new<br />\nfan unit.<br />\n4.4.4.Upon acceptance of the cost estimate and authorization to proceed by the KO, the Contractor<br />\nshall overhaul the fan unit in accordance with the OEM procedures, specifications,<br />\nreferences, standard practices and the references cited in section 2 of this specification.<br />\n4.4.5.The government reserves the right to dispose of the fan unit(s) if is Beyond Economic<br />\nRepair (BER). The contractor will dispose of the unit at a predetermined cost to the<br />\ngovernment. The contractor shall provide a scrap credit to the government or a price to<br />\ndiscard any fan unit BER.<br />\n4.4.5.1. The Coast Guard KO will determine the disposition of any fan unit delivered for<br />\noverhaul that is Beyond Economical Repair (BER).<br />\n4.4.5.2. If the fan unit is BER, the government reserves the right to purchase an identical<br />\nnew fan unit from the Contractor.<br />\n4.5. Fan- Overhaul. The Contractor shall accomplish the following tasks for each fan unit, using<br />\nreferences sited in Section 2 of this specification. The Contractor shall test, remove, overhaul,<br />\nand balance each fan unit.<br />\n4.5.1.Disassembly. The Contractor must disassemble the fan assembly for overhaul; follow the<br />\nsteps outlined in TP S9512-A3-MMA-010 Chapter 6. Prior to fan disassembly, the<br />\nContractor must measure air gap reading and bearing clearances. Submit a CFR. Take care<br />\nto match mark components to avoid the need for wheel rebalancing.<br />\n4.5.2.Cleaning. Clean the interior and exterior fan assembly surfaces, including housing, fan<br />\nblade, and end bell surf aces by first using suction, then with a soapy water solution, and<br />\nfallowed by a thorough rinsing of all metal surfaces. Ensure that there are no cleaning fluid<br />\nresidues or injurious effects on cleaned surfaces.<br />\n4 .5 .3 .Inspection and documentation. After surface preparation and before surface coating, visually<br />\ninspect the fan assembly surfaces including bearing surfaces for cracks, areas of distortion,<br />\nand deterioration.<br />\n4.5.4.Preservation. Prepare and coat the fan casing surfaces in using the system specified for<br />\n&quot;Machinery, Operating Temperatures Under 200-degree F, Unmachined Surfaces&quot; in<br />\nCOMDTINST Ml 0360.3, Appendix B (Cutter and Boat Interior Paint Systems). Select<br />\nfinish/topcoat color to match existing adjacent surfaces.<br />\n4.6. Motor - Overhaul. The Contractor shall accomplish the following tasks for each ventilation motor<br />\nassembly, using references sited in Section 2 of this specification.<br />\n4.6.1.Disassembly. The Contractor shall disassemble each ventilation fan motor from its fan.<br />\nDuring disassembly, ensure that each fan motor is properly marked to indicate the fan it was<br />\nremoved from. Remove end plates and rotor from motor frame. Remove existing motor<br />\nbearings and dispose of properly.<br />\n4.6.2.Inspection. The Contractor must disassemble, clean, inspect, and test all fan motor<br />\ncomponents in accordance with SFLC Std Spec 3020 paragraph 3.3. Submit CFR all<br />\nperformed inspections and testing, including but not limited to, initial visual conditions,<br />\ninitial insulation resistance tests, winding tests and final acceptance tests.<br />\n4.6.2.1. Rewind shall not be part of the overhaul process unless test results by the<br />\nContractor support rewind and is approved by the COR. High Potential tests shall only<br />\nbe performed for ventilation fan motors which require rewind.<br />\n4 .6 .3 .Re-assembly. Renew all motor bearings in accordance with SFLC Std Spec 3 02 0 paragraph<br />\n3.4.3. The Contractor must reassemble the motor in accordance with SFLC Std Spec 3020<br />\nparagraph 3.4.6. The Contractor must perform motor testing in with SFLC Std Spec 3020<br />\nparagraph 3 .5.<br />\n4.7. Fan and Motor Assembly Restoration. The Contractor shall reassemble each fan and motor<br />\nassembly using new gaskets and stainless-steel hardware; couple the fan to the motor assembly.<br />\nRenew all original data or label plates after completing external preservation. A separate labelplate made of similar material as the original label plate shall be attached to the fan unit stating<br />\nthe Contractor&#39;s name, contract number and date of overhaul.<br />\n4.8. Dynamic Balancing. The Contractor shall dynamically balance the rotating elements along with<br />\nassociated equipment as a unit (fan blade and motor installed and in casing), in accordance with<br />\nISO 2953. Submit a written balance report.<br />\n4.9. Operational Test- Post Repairs. After completion of work, the Contractor shall conduct an<br />\noperational test of each fan and motor assembly to prove satisfactory operating condition.<br />\nPerform an operational test of each overhauled ventilation fan, ensuring the fan operates in the<br />\ncorrect direction, with no excessive vibration or noise. Operate the fan assembly at its rated speed<br />\nfor 30 minutes. Measure and record the overhauled tube axial fan&#39;s CFM output to verify it is<br />\nwithin the manufacturer&#39;s rated tolerances. Submit a CFR.<br />\n4.10. Preservation, Packing, and Marking. The overhauled fan unit shall be delivered to the<br />\nCoast Guard completely assembled and in a ready to operate condition and configuration. The<br />\nContractor must return to the appropriate USCG representative via delivery or third-party<br />\nshipping. Contractor must provide any new gaskets for connections. The fan unit must be<br />\npackaged that protects it from moisture, rain, rust, corrosion, and vibration, which may constitute<br />\na standard export wooden box with plastic foam. The fan unit shall be completely sealed within a<br />\n6 mil (minimum) clear plastic bag, with sufficient units of desiccant to prevent moisture build up<br />\nand corrosion<br />\n5. Government Furnished Property.<br />\n5.1.Ventilation Fan (Vaneaxial), Model Al-1/2A4W5, QTY 2<br />\n6. Security Requirement. Base access is not required. If needed, contractor shall have a valid<br />\ngovernment issued ID (or driver&#39;s license) and show identification at the security gate. A Coast Guard<br />\nrepresentative from the cutter or Product Line will sponsor and escort vendor to the cutter. The<br />\ncontractor must coordinate any base access with the designated point of contact ahead of time to<br />\nensure administrative processing.<br />\n7. Place of Performance. Contractor&#39;s repair facility.<br />\n8. Period of Performance. 5-May-2025 to 5-June-2025<br />\n9. Points of Contact.<br />\n9 .1. USCG-SFLC-LREPL Asset Management: LTJG Mikael Axelsson, Mikael.J.Axelsson@uscg.mil,<br />\n(510) 493-1827<br />\n10. Contractor&#39;s Proposal.<br />\n10.1. Documentation. The Contractor must include at least the following in their proposal for<br />\nthis requirement: basic information (name, company name, contact details, the date, Unique<br />\nEntity ID), company overview and relevant qualifications, past performance, scope of work for<br />\nthe tasks and deliverables, project timeline, cost including a breakdown of the cost of each item<br />\nor service, terms and conditions, attachments/bid sheet, description of subcontractors (if any), and<br />\nsignature of the authorized person.<br />\n10.2. Proposal Evaluation Criteria. Award of this requirement shall be made to the vendor<br />\nwhose proposal offers the greatest value to the government regarding price, ability to meet all<br />\ntechnical requirements of the specification, and past performance.<br />\n11. Notes.<br />\n11. 1. Vaneaxial Fan Data - Supply Fan 1-22-2<br />\no Model: XA1-1/2A4W6, 1.25 HP, single speed, 3600 RPM for 440VAC/60HZ/3-<br />\nphase, steel housing and aluminum impeller, fixed pitch vaneaxial, motor shall<br />\nconform to IEEE-45 specifications and rated for 65-degree Celsius ambient operation.<br />\no Serial Number: N-1248 Item 16Vaneaxial Fan Data - Supply Fan 2-40-1<br />\n12. Photos.<br />\no Model: XA1-1/2A4W6, 1.25 HP, single speed, 3600 RPM for 440VAC/60HZ/3-<br />\nphase, steel housing and aluminum impeller, fixed pitch vaneaxial, motor shall<br />\nconform to IEEE-45 specifications and rated for 65-degree Celsius ambient operation.<br />\no Serial Number: SN14955-01-08<br />\n12.1. Motor data for Supply Fan 1-22-2.</p>","text":"TECHNICAL SERVICES\n\nUSCGC ALEX HALEY (WMEC-282) - Z12204\n\nEVALUATION AND REPAIR FAN UNIT(S)\n\n1. Objective. The objective of this document sets forth the receipt, disassembly, inspections,\n\ncondition/test reports, overhaul/repair, reassembly, testing, preservation, packaging, packing, and\n\nmarking of Navy standard fan unit(s) used on the U.S. Coast Guard Cutter ALEX HALEY.\n\n2. References. For any listed references to be distributed, the contractor must be registered in the Joint\n\nCertification Program (JCP) through Defense Logistics Agency (DLA) and provide your JCP number\n\nand expiration date to the listed point of contact (POC) for this work.\n\n2 .1. Specification Order of Precedence. In the event of a conflict between the text of this specification\n\nand the references cited herein, the text of this specification shall take precedence. Nothing in this\n\nspecification, however, supersedes applicable laws and regulations unless a specific ex emption\n\nhas been obtained.\n\n2.2. Government Documents. The following specifications and standards form a part of this\n\nspecification to the extent specified herein. Unless otherwise specified, the documents listed here\n\nby number and date shall be those in the current Department of Defense Single Stock Point of\n\nSpecification and Standards (DODSSP) and supplements thereto.\n\n2.2.1.Naval Ships Technical Manual (NSTM), S9512-A3-MMA-010, Chapter 512, Fan,\n\nVaneaxial and Tubeaxial, 1987\n\n2.2.2.Federal Standard, FED-STD-595C, dated 07/31/2008, Colors Used in Government\n\nProcurement\n\n2.3. United States Coast Guard Drawings and Publications. The following specifications and\n\nstandards form a part of this specification to the extent specified herein.\n\n2.3.1.United States Coast Guard Commandant Instruction (COMDTINST) M10360.3 (series),\n\nCoatings and Color Manual\n\n2.3.2.United States Coast Guard Technical Manual TP: 7148-512-A, dated08/24/2007, Standard\n\nXA Vaneaxial Fan\n\n2.3.3.Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022,\n\nGeneral Requirements\n\n2.3.4.Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3020), 2022,\n\nOverhaul AC Electrical Motors\n\n2.3.5.Specification Packaging and Labeling SP-PP&M Rev D dated 6/6/11\n\n2.4. Commercial Documents. The following documents form a part of this specification to the extent\n\nspecified herein. The documents shall be the version listed by number and date from the\n\nreferenced industry organization. Commercial documents may be listed in the Department of\n\nDefense Index of Specifications and Standards (DODISS).\n\n2.4.1.American Society for Testing & Materials (ASTM) D3951-98, dated 2004, Standard\n\nPractice for Commercial Packaging\n\n2.4.2.International Standard Organization (ISO) 2953, 1999, Mechanical Vibration, Balancing\n\nMachines, Description and Evaluation\n\n2.4.3.Steel Structure Painting Council, SSPC-SP 3, dated 11/01/1982, Power Tool Cleaning\n\n3. Background. This requirement is for the contractor to evaluate and repair the ventilation fan(s)\n\n(vaneaxial) listed below Table 1 and Section 5. The fan units are designated as Supply Fan 1-22-2 and\n\nSupply Fan 2-40-1.Table 1 - Ventilation Fan(s) for Overhaul\n\nSystem / Fan Number Model Number Location\n\nApproximate\n\nDimensions/Weight\n\nSl-22-2\n\nAl-1/2 Class Z, 1,799\n\nDry Stores (1-23-0-A)\n\n20\" long x 17 .5\"\n\nCFM 1.25 HP Diameter / 160 lbs.\n\nS2-40-1 Al-1/2 Class Z, 1,450 Salvage Storeroom #4 20\" long x 17 .5\"\n\nCFM 1.25 HP (2-36-0-A) Diameter / 160 lbs.\n\n4. Tasks. The contractor shall provide services of which includes but may not limited to:\n\n4.1. General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and\n\nin this item, as applicable, during the performance of this availability. The requirements of this\n\nwork apply to all work under the scope of this contract, whether explicitly stated in all following\n\nwork items or not, and to all other work subsequently authorized by changes, modifications, or\n\nextensions to the contract.\n\n4.2. The Contractor shall submit a Receiving Inspection Report to the Coast Guard Contracting\n\nOfficer (KO), Contracting Office's Representative (COR), and other listed Points of Contacts\n\n(POCs) within 2 days of receiving the government furnished property (GFP). The report shall\n\ndocument the make, part number, and/or model. This report shall also include digital\n\nphotographic documentation of the crate and its contents.\n\n4.2.1.It is assumed that the fan unit(s) will arrive in a re-usable container. In the event the\n\ncontainer is deemed unusable the contractor shall state so as part of the inspection report and\n\nprovide photo documentation.\n\n4.3. Inspections, repair/overhaul and testing of the fan unit(s) shall be accomplished in accordance\n\nwith the OEM procedures, specifications, references, and standard practices. The Contractor shall\n\nconform to all requirements specified throughout this specification during performance of this\n\ncontract. In the event of a conflict between the text of this specification and the references cited\n\nherein, the text of this specification takes precedence. Nothing in this specification; however,\n\nsupersedes applicable laws and regulations unless a specific exemption has been obtained.\n\n4.3.1.The overhaul requirements described herein are considered the minimumnecessary and are\n\nnot intended to replace any procedures, controls, examinations, or tests normally employed\n\nby the Contractor to assure the quality of the product.\n\n4 .3 .2. The overhaul of the fan unit( s) is intended to return the unit's performance and appearance\n\nto a condition capable of functioning and performing in the same manner as an identical new\n\nunit, as referred to as serviceable \"A\" condition.\n\n4.4. Condition Found Report (CFR).\n\n4.4.1.Preliminary disassembly and inspection of each fan unit shall be conducted in accordance\n\nwith OEM procedures, specifications, references, and standard practices to determine the\n\ntotal estimated cost to repair, including material, labor, testing, Preservation, Packing and\n\nMarking (PP&M) costs. A CFR shall be submitted to the KO, COR, and other listed POCs\n\nwithin 5 days of the completion of the Receiving Inspection Report detailing the repair parts\n\nrecommended for replacement and a total repair cost.\n\n4.4.2. The CFR shall be submitted to the KO, COR, and other listed POCs for review and approval\n\nprior to the start of any repair or order of any material. The Contractor shall also provide the\n\nreplacement cost of an identical new fan unit for comparison to the overhaul cost. At a\n\nminimum, mandatory replacement parts shall include all bearings, bushings, seals and\n\ngaskets. All parts that are worn, have an improper fit and or damaged beyond the OEM\n\ntolerances, shall be repaired or replaced as determined by the Contractor.\n\n4.4.3.The detailed cost estimate shall contain the following as a minimum: the part number, NSN\n\nand serial number of the fan unit, the contract number and deliveiy order number for the fan\n\nunit, a listing of individual parts by part number, cost and quantity, a listing of labor hoursand labor rate to perform the overhaul, testing, and packaging, the cost of an identical new\n\nfan unit.\n\n4.4.4.Upon acceptance of the cost estimate and authorization to proceed by the KO, the Contractor\n\nshall overhaul the fan unit in accordance with the OEM procedures, specifications,\n\nreferences, standard practices and the references cited in section 2 of this specification.\n\n4.4.5.The government reserves the right to dispose of the fan unit(s) if is Beyond Economic\n\nRepair (BER). The contractor will dispose of the unit at a predetermined cost to the\n\ngovernment. The contractor shall provide a scrap credit to the government or a price to\n\ndiscard any fan unit BER.\n\n4.4.5.1. The Coast Guard KO will determine the disposition of any fan unit delivered for\n\noverhaul that is Beyond Economical Repair (BER).\n\n4.4.5.2. If the fan unit is BER, the government reserves the right to purchase an identical\n\nnew fan unit from the Contractor.\n\n4.5. Fan- Overhaul. The Contractor shall accomplish the following tasks for each fan unit, using\n\nreferences sited in Section 2 of this specification. The Contractor shall test, remove, overhaul,\n\nand balance each fan unit.\n\n4.5.1.Disassembly. The Contractor must disassemble the fan assembly for overhaul; follow the\n\nsteps outlined in TP S9512-A3-MMA-010 Chapter 6. Prior to fan disassembly, the\n\nContractor must measure air gap reading and bearing clearances. Submit a CFR. Take care\n\nto match mark components to avoid the need for wheel rebalancing.\n\n4.5.2.Cleaning. Clean the interior and exterior fan assembly surfaces, including housing, fan\n\nblade, and end bell surf aces by first using suction, then with a soapy water solution, and\n\nfallowed by a thorough rinsing of all metal surfaces. Ensure that there are no cleaning fluid\n\nresidues or injurious effects on cleaned surfaces.\n\n4 .5 .3 .Inspection and documentation. After surface preparation and before surface coating, visually\n\ninspect the fan assembly surfaces including bearing surfaces for cracks, areas of distortion,\n\nand deterioration.\n\n4.5.4.Preservation. Prepare and coat the fan casing surfaces in using the system specified for\n\n\"Machinery, Operating Temperatures Under 200-degree F, Unmachined Surfaces\" in\n\nCOMDTINST Ml 0360.3, Appendix B (Cutter and Boat Interior Paint Systems). Select\n\nfinish/topcoat color to match existing adjacent surfaces.\n\n4.6. Motor - Overhaul. The Contractor shall accomplish the following tasks for each ventilation motor\n\nassembly, using references sited in Section 2 of this specification.\n\n4.6.1.Disassembly. The Contractor shall disassemble each ventilation fan motor from its fan.\n\nDuring disassembly, ensure that each fan motor is properly marked to indicate the fan it was\n\nremoved from. Remove end plates and rotor from motor frame. Remove existing motor\n\nbearings and dispose of properly.\n\n4.6.2.Inspection. The Contractor must disassemble, clean, inspect, and test all fan motor\n\ncomponents in accordance with SFLC Std Spec 3020 paragraph 3.3. Submit CFR all\n\nperformed inspections and testing, including but not limited to, initial visual conditions,\n\ninitial insulation resistance tests, winding tests and final acceptance tests.\n\n4.6.2.1. Rewind shall not be part of the overhaul process unless test results by the\n\nContractor support rewind and is approved by the COR. High Potential tests shall only\n\nbe performed for ventilation fan motors which require rewind.\n\n4 .6 .3 .Re-assembly. Renew all motor bearings in accordance with SFLC Std Spec 3 02 0 paragraph\n\n3.4.3. The Contractor must reassemble the motor in accordance with SFLC Std Spec 3020\n\nparagraph 3.4.6. The Contractor must perform motor testing in with SFLC Std Spec 3020\n\nparagraph 3 .5.\n\n4.7. Fan and Motor Assembly Restoration. The Contractor shall reassemble each fan and motor\n\nassembly using new gaskets and stainless-steel hardware; couple the fan to the motor assembly.\n\nRenew all original data or label plates after completing external preservation. A separate labelplate made of similar material as the original label plate shall be attached to the fan unit stating\n\nthe Contractor's name, contract number and date of overhaul.\n\n4.8. Dynamic Balancing. The Contractor shall dynamically balance the rotating elements along with\n\nassociated equipment as a unit (fan blade and motor installed and in casing), in accordance with\n\nISO 2953. Submit a written balance report.\n\n4.9. Operational Test- Post Repairs. After completion of work, the Contractor shall conduct an\n\noperational test of each fan and motor assembly to prove satisfactory operating condition.\n\nPerform an operational test of each overhauled ventilation fan, ensuring the fan operates in the\n\ncorrect direction, with no excessive vibration or noise. Operate the fan assembly at its rated speed\n\nfor 30 minutes. Measure and record the overhauled tube axial fan's CFM output to verify it is\n\nwithin the manufacturer's rated tolerances. Submit a CFR.\n\n4.10. Preservation, Packing, and Marking. The overhauled fan unit shall be delivered to the\n\nCoast Guard completely assembled and in a ready to operate condition and configuration. The\n\nContractor must return to the appropriate USCG representative via delivery or third-party\n\nshipping. Contractor must provide any new gaskets for connections. The fan unit must be\n\npackaged that protects it from moisture, rain, rust, corrosion, and vibration, which may constitute\n\na standard export wooden box with plastic foam. The fan unit shall be completely sealed within a\n\n6 mil (minimum) clear plastic bag, with sufficient units of desiccant to prevent moisture build up\n\nand corrosion\n\n5. Government Furnished Property.\n\n5.1.Ventilation Fan (Vaneaxial), Model Al-1/2A4W5, QTY 2\n\n6. Security Requirement. Base access is not required. If needed, contractor shall have a valid\n\ngovernment issued ID (or driver's license) and show identification at the security gate. A Coast Guard\n\nrepresentative from the cutter or Product Line will sponsor and escort vendor to the cutter. The\n\ncontractor must coordinate any base access with the designated point of contact ahead of time to\n\nensure administrative processing.\n\n7. Place of Performance. Contractor's repair facility.\n\n8. Period of Performance. 5-May-2025 to 5-June-2025\n\n9. Points of Contact.\n\n9 .1. USCG-SFLC-LREPL Asset Management: LTJG Mikael Axelsson, Mikael.J.Axelsson@uscg.mil,\n\n(510) 493-1827\n\n10. Contractor's Proposal.\n\n10.1. Documentation. The Contractor must include at least the following in their proposal for\n\nthis requirement: basic information (name, company name, contact details, the date, Unique\n\nEntity ID), company overview and relevant qualifications, past performance, scope of work for\n\nthe tasks and deliverables, project timeline, cost including a breakdown of the cost of each item\n\nor service, terms and conditions, attachments/bid sheet, description of subcontractors (if any), and\n\nsignature of the authorized person.\n\n10.2. Proposal Evaluation Criteria. Award of this requirement shall be made to the vendor\n\nwhose proposal offers the greatest value to the government regarding price, ability to meet all\n\ntechnical requirements of the specification, and past performance.\n\n11. Notes.\n\n11. 1. Vaneaxial Fan Data - Supply Fan 1-22-2\n\no Model: XA1-1/2A4W6, 1.25 HP, single speed, 3600 RPM for 440VAC/60HZ/3-\n\nphase, steel housing and aluminum impeller, fixed pitch vaneaxial, motor shall\n\nconform to IEEE-45 specifications and rated for 65-degree Celsius ambient operation.\n\no Serial Number: N-1248 Item 16Vaneaxial Fan Data - Supply Fan 2-40-1\n\n12. Photos.\n\no Model: XA1-1/2A4W6, 1.25 HP, single speed, 3600 RPM for 440VAC/60HZ/3-\n\nphase, steel housing and aluminum impeller, fixed pitch vaneaxial, motor shall\n\nconform to IEEE-45 specifications and rated for 65-degree Celsius ambient operation.\n\no Serial Number: SN14955-01-08\n\n12.1. Motor data for Supply Fan 1-22-2.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70Z085Q12971","place_of_performance":{"zip":"99619","city":{"code":"40950","name":"Kodiak"},"state":{"code":"AK","name":"Alaska"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J020"}],"due_at":"2025-05-05T15:00:00Z","due_date":"2025-05-05","closes_at":"2025-05-05T15:00:00Z","awardable":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","state":"AK","county":"02150","county_name":"Kodiak Island Borough","city":"0240950","city_name":"Kodiak","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-16T03:27:42.731603Z","principal_notice_id":"131f6567affe45f49cd116bfdf6c8722","description":{"text":"TECHNICAL SERVICES\n\nUSCGC ALEX HALEY (WMEC-282) - Z12204\n\nEVALUATION AND REPAIR FAN UNIT(S)\n\n1. Objective. The objective of this document sets forth the receipt, disassembly, inspections,\n\ncondition/test reports, overhaul/repair, reassembly, testing, preservation, packaging, packing, and\n\nmarking of Navy standard fan unit(s) used on the U.S. Coast Guard Cutter ALEX HALEY.\n\n2. References. For any listed references to be distributed, the contractor must be registered in the Joint\n\nCertification Program (JCP) through Defense Logistics Agency (DLA) and provide your JCP number\n\nand expiration date to the listed point of contact (POC) for this work.\n\n2 .1. Specification Order of Precedence. In the event of a conflict between the text of this specification\n\nand the references cited herein, the text of this specification shall take precedence. Nothing in this\n\nspecification, however, supersedes applicable laws and regulations unless a specific ex emption\n\nhas been obtained.\n\n2.2. Government Documents. The following specifications and standards form a part of this\n\nspecification to the extent specified herein. Unless otherwise specified, the documents listed here\n\nby number and date shall be those in the current Department of Defense Single Stock Point of\n\nSpecification and Standards (DODSSP) and supplements thereto.\n\n2.2.1.Naval Ships Technical Manual (NSTM), S9512-A3-MMA-010, Chapter 512, Fan,\n\nVaneaxial and Tubeaxial, 1987\n\n2.2.2.Federal Standard, FED-STD-595C, dated 07/31/2008, Colors Used in Government\n\nProcurement\n\n2.3. United States Coast Guard Drawings and Publications. The following specifications and\n\nstandards form a part of this specification to the extent specified herein.\n\n2.3.1.United States Coast Guard Commandant Instruction (COMDTINST) M10360.3 (series),\n\nCoatings and Color Manual\n\n2.3.2.United States Coast Guard Technical Manual TP: 7148-512-A, dated08/24/2007, Standard\n\nXA Vaneaxial Fan\n\n2.3.3.Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022,\n\nGeneral Requirements\n\n2.3.4.Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3020), 2022,\n\nOverhaul AC Electrical Motors\n\n2.3.5.Specification Packaging and Labeling SP-PP&M Rev D dated 6/6/11\n\n2.4. Commercial Documents. The following documents form a part of this specification to the extent\n\nspecified herein. The documents shall be the version listed by number and date from the\n\nreferenced industry organization. Commercial documents may be listed in the Department of\n\nDefense Index of Specifications and Standards (DODISS).\n\n2.4.1.American Society for Testing & Materials (ASTM) D3951-98, dated 2004, Standard\n\nPractice for Commercial Packaging\n\n2.4.2.International Standard Organization (ISO) 2953, 1999, Mechanical Vibration, Balancing\n\nMachines, Description and Evaluation\n\n2.4.3.Steel Structure Painting Council, SSPC-SP 3, dated 11/01/1982, Power Tool Cleaning\n\n3. Background. This requirement is for the contractor to evaluate and repair the ventilation fan(s)\n\n(vaneaxial) listed below Table 1 and Section 5. The fan units are designated as Supply Fan 1-22-2 and\n\nSupply Fan 2-40-1.Table 1 - Ventilation Fan(s) for Overhaul\n\nSystem / Fan Number Model Number Location\n\nApproximate\n\nDimensions/Weight\n\nSl-22-2\n\nAl-1/2 Class Z, 1,799\n\nDry Stores (1-23-0-A)\n\n20\" long x 17 .5\"\n\nCFM 1.25 HP Diameter / 160 lbs.\n\nS2-40-1 Al-1/2 Class Z, 1,450 Salvage Storeroom #4 20\" long x 17 .5\"\n\nCFM 1.25 HP (2-36-0-A) Diameter / 160 lbs.\n\n4. Tasks. The contractor shall provide services of which includes but may not limited to:\n\n4.1. General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and\n\nin this item, as applicable, during the performance of this availability. The requirements of this\n\nwork apply to all work under the scope of this contract, whether explicitly stated in all following\n\nwork items or not, and to all other work subsequently authorized by changes, modifications, or\n\nextensions to the contract.\n\n4.2. The Contractor shall submit a Receiving Inspection Report to the Coast Guard Contracting\n\nOfficer (KO), Contracting Office's Representative (COR), and other listed Points of Contacts\n\n(POCs) within 2 days of receiving the government furnished property (GFP). The report shall\n\ndocument the make, part number, and/or model. This report shall also include digital\n\nphotographic documentation of the crate and its contents.\n\n4.2.1.It is assumed that the fan unit(s) will arrive in a re-usable container. In the event the\n\ncontainer is deemed unusable the contractor shall state so as part of the inspection report and\n\nprovide photo documentation.\n\n4.3. Inspections, repair/overhaul and testing of the fan unit(s) shall be accomplished in accordance\n\nwith the OEM procedures, specifications, references, and standard practices. The Contractor shall\n\nconform to all requirements specified throughout this specification during performance of this\n\ncontract. In the event of a conflict between the text of this specification and the references cited\n\nherein, the text of this specification takes precedence. Nothing in this specification; however,\n\nsupersedes applicable laws and regulations unless a specific exemption has been obtained.\n\n4.3.1.The overhaul requirements described herein are considered the minimumnecessary and are\n\nnot intended to replace any procedures, controls, examinations, or tests normally employed\n\nby the Contractor to assure the quality of the product.\n\n4 .3 .2. The overhaul of the fan unit( s) is intended to return the unit's performance and appearance\n\nto a condition capable of functioning and performing in the same manner as an identical new\n\nunit, as referred to as serviceable \"A\" condition.\n\n4.4. Condition Found Report (CFR).\n\n4.4.1.Preliminary disassembly and inspection of each fan unit shall be conducted in accordance\n\nwith OEM procedures, specifications, references, and standard practices to determine the\n\ntotal estimated cost to repair, including material, labor, testing, Preservation, Packing and\n\nMarking (PP&M) costs. A CFR shall be submitted to the KO, COR, and other listed POCs\n\nwithin 5 days of the completion of the Receiving Inspection Report detailing the repair parts\n\nrecommended for replacement and a total repair cost.\n\n4.4.2. The CFR shall be submitted to the KO, COR, and other listed POCs for review and approval\n\nprior to the start of any repair or order of any material. The Contractor shall also provide the\n\nreplacement cost of an identical new fan unit for comparison to the overhaul cost. At a\n\nminimum, mandatory replacement parts shall include all bearings, bushings, seals and\n\ngaskets. All parts that are worn, have an improper fit and or damaged beyond the OEM\n\ntolerances, shall be repaired or replaced as determined by the Contractor.\n\n4.4.3.The detailed cost estimate shall contain the following as a minimum: the part number, NSN\n\nand serial number of the fan unit, the contract number and deliveiy order number for the fan\n\nunit, a listing of individual parts by part number, cost and quantity, a listing of labor hoursand labor rate to perform the overhaul, testing, and packaging, the cost of an identical new\n\nfan unit.\n\n4.4.4.Upon acceptance of the cost estimate and authorization to proceed by the KO, the Contractor\n\nshall overhaul the fan unit in accordance with the OEM procedures, specifications,\n\nreferences, standard practices and the references cited in section 2 of this specification.\n\n4.4.5.The government reserves the right to dispose of the fan unit(s) if is Beyond Economic\n\nRepair (BER). The contractor will dispose of the unit at a predetermined cost to the\n\ngovernment. The contractor shall provide a scrap credit to the government or a price to\n\ndiscard any fan unit BER.\n\n4.4.5.1. The Coast Guard KO will determine the disposition of any fan unit delivered for\n\noverhaul that is Beyond Economical Repair (BER).\n\n4.4.5.2. If the fan unit is BER, the government reserves the right to purchase an identical\n\nnew fan unit from the Contractor.\n\n4.5. Fan- Overhaul. The Contractor shall accomplish the following tasks for each fan unit, using\n\nreferences sited in Section 2 of this specification. The Contractor shall test, remove, overhaul,\n\nand balance each fan unit.\n\n4.5.1.Disassembly. The Contractor must disassemble the fan assembly for overhaul; follow the\n\nsteps outlined in TP S9512-A3-MMA-010 Chapter 6. Prior to fan disassembly, the\n\nContractor must measure air gap reading and bearing clearances. Submit a CFR. Take care\n\nto match mark components to avoid the need for wheel rebalancing.\n\n4.5.2.Cleaning. Clean the interior and exterior fan assembly surfaces, including housing, fan\n\nblade, and end bell surf aces by first using suction, then with a soapy water solution, and\n\nfallowed by a thorough rinsing of all metal surfaces. Ensure that there are no cleaning fluid\n\nresidues or injurious effects on cleaned surfaces.\n\n4 .5 .3 .Inspection and documentation. After surface preparation and before surface coating, visually\n\ninspect the fan assembly surfaces including bearing surfaces for cracks, areas of distortion,\n\nand deterioration.\n\n4.5.4.Preservation. Prepare and coat the fan casing surfaces in using the system specified for\n\n\"Machinery, Operating Temperatures Under 200-degree F, Unmachined Surfaces\" in\n\nCOMDTINST Ml 0360.3, Appendix B (Cutter and Boat Interior Paint Systems). Select\n\nfinish/topcoat color to match existing adjacent surfaces.\n\n4.6. Motor - Overhaul. The Contractor shall accomplish the following tasks for each ventilation motor\n\nassembly, using references sited in Section 2 of this specification.\n\n4.6.1.Disassembly. The Contractor shall disassemble each ventilation fan motor from its fan.\n\nDuring disassembly, ensure that each fan motor is properly marked to indicate the fan it was\n\nremoved from. Remove end plates and rotor from motor frame. Remove existing motor\n\nbearings and dispose of properly.\n\n4.6.2.Inspection. The Contractor must disassemble, clean, inspect, and test all fan motor\n\ncomponents in accordance with SFLC Std Spec 3020 paragraph 3.3. Submit CFR all\n\nperformed inspections and testing, including but not limited to, initial visual conditions,\n\ninitial insulation resistance tests, winding tests and final acceptance tests.\n\n4.6.2.1. Rewind shall not be part of the overhaul process unless test results by the\n\nContractor support rewind and is approved by the COR. High Potential tests shall only\n\nbe performed for ventilation fan motors which require rewind.\n\n4 .6 .3 .Re-assembly. Renew all motor bearings in accordance with SFLC Std Spec 3 02 0 paragraph\n\n3.4.3. The Contractor must reassemble the motor in accordance with SFLC Std Spec 3020\n\nparagraph 3.4.6. The Contractor must perform motor testing in with SFLC Std Spec 3020\n\nparagraph 3 .5.\n\n4.7. Fan and Motor Assembly Restoration. The Contractor shall reassemble each fan and motor\n\nassembly using new gaskets and stainless-steel hardware; couple the fan to the motor assembly.\n\nRenew all original data or label plates after completing external preservation. A separate labelplate made of similar material as the original label plate shall be attached to the fan unit stating\n\nthe Contractor's name, contract number and date of overhaul.\n\n4.8. Dynamic Balancing. The Contractor shall dynamically balance the rotating elements along with\n\nassociated equipment as a unit (fan blade and motor installed and in casing), in accordance with\n\nISO 2953. Submit a written balance report.\n\n4.9. Operational Test- Post Repairs. After completion of work, the Contractor shall conduct an\n\noperational test of each fan and motor assembly to prove satisfactory operating condition.\n\nPerform an operational test of each overhauled ventilation fan, ensuring the fan operates in the\n\ncorrect direction, with no excessive vibration or noise. Operate the fan assembly at its rated speed\n\nfor 30 minutes. Measure and record the overhauled tube axial fan's CFM output to verify it is\n\nwithin the manufacturer's rated tolerances. Submit a CFR.\n\n4.10. Preservation, Packing, and Marking. The overhauled fan unit shall be delivered to the\n\nCoast Guard completely assembled and in a ready to operate condition and configuration. The\n\nContractor must return to the appropriate USCG representative via delivery or third-party\n\nshipping. Contractor must provide any new gaskets for connections. The fan unit must be\n\npackaged that protects it from moisture, rain, rust, corrosion, and vibration, which may constitute\n\na standard export wooden box with plastic foam. The fan unit shall be completely sealed within a\n\n6 mil (minimum) clear plastic bag, with sufficient units of desiccant to prevent moisture build up\n\nand corrosion\n\n5. Government Furnished Property.\n\n5.1.Ventilation Fan (Vaneaxial), Model Al-1/2A4W5, QTY 2\n\n6. Security Requirement. Base access is not required. If needed, contractor shall have a valid\n\ngovernment issued ID (or driver's license) and show identification at the security gate. A Coast Guard\n\nrepresentative from the cutter or Product Line will sponsor and escort vendor to the cutter. The\n\ncontractor must coordinate any base access with the designated point of contact ahead of time to\n\nensure administrative processing.\n\n7. Place of Performance. Contractor's repair facility.\n\n8. Period of Performance. 5-May-2025 to 5-June-2025\n\n9. Points of Contact.\n\n9 .1. USCG-SFLC-LREPL Asset Management: LTJG Mikael Axelsson, Mikael.J.Axelsson@uscg.mil,\n\n(510) 493-1827\n\n10. Contractor's Proposal.\n\n10.1. Documentation. The Contractor must include at least the following in their proposal for\n\nthis requirement: basic information (name, company name, contact details, the date, Unique\n\nEntity ID), company overview and relevant qualifications, past performance, scope of work for\n\nthe tasks and deliverables, project timeline, cost including a breakdown of the cost of each item\n\nor service, terms and conditions, attachments/bid sheet, description of subcontractors (if any), and\n\nsignature of the authorized person.\n\n10.2. Proposal Evaluation Criteria. Award of this requirement shall be made to the vendor\n\nwhose proposal offers the greatest value to the government regarding price, ability to meet all\n\ntechnical requirements of the specification, and past performance.\n\n11. Notes.\n\n11. 1. Vaneaxial Fan Data - Supply Fan 1-22-2\n\no Model: XA1-1/2A4W6, 1.25 HP, single speed, 3600 RPM for 440VAC/60HZ/3-\n\nphase, steel housing and aluminum impeller, fixed pitch vaneaxial, motor shall\n\nconform to IEEE-45 specifications and rated for 65-degree Celsius ambient operation.\n\no Serial Number: N-1248 Item 16Vaneaxial Fan Data - Supply Fan 2-40-1\n\n12. Photos.\n\no Model: XA1-1/2A4W6, 1.25 HP, single speed, 3600 RPM for 440VAC/60HZ/3-\n\nphase, steel housing and aluminum impeller, fixed pitch vaneaxial, motor shall\n\nconform to IEEE-45 specifications and rated for 65-degree Celsius ambient operation.\n\no Serial Number: SN14955-01-08\n\n12.1. Motor data for Supply Fan 1-22-2.","html":"<p>TECHNICAL SERVICES<br />\nUSCGC ALEX HALEY (WMEC-282) - Z12204<br />\nEVALUATION AND REPAIR FAN UNIT(S)<br />\n1. Objective. The objective of this document sets forth the receipt, disassembly, inspections,<br />\ncondition/test reports, overhaul/repair, reassembly, testing, preservation, packaging, packing, and<br />\nmarking of Navy standard fan unit(s) used on the U.S. Coast Guard Cutter ALEX HALEY.<br />\n2. References. For any listed references to be distributed, the contractor must be registered in the Joint<br />\nCertification Program (JCP) through Defense Logistics Agency (DLA) and provide your JCP number<br />\nand expiration date to the listed point of contact (POC) for this work.<br />\n2 .1. Specification Order of Precedence. In the event of a conflict between the text of this specification<br />\nand the references cited herein, the text of this specification shall take precedence. Nothing in this<br />\nspecification, however, supersedes applicable laws and regulations unless a specific ex emption<br />\nhas been obtained.<br />\n2.2. Government Documents. The following specifications and standards form a part of this<br />\nspecification to the extent specified herein. Unless otherwise specified, the documents listed here<br />\nby number and date shall be those in the current Department of Defense Single Stock Point of<br />\nSpecification and Standards (DODSSP) and supplements thereto.<br />\n2.2.1.Naval Ships Technical Manual (NSTM), S9512-A3-MMA-010, Chapter 512, Fan,<br />\nVaneaxial and Tubeaxial, 1987<br />\n2.2.2.Federal Standard, FED-STD-595C, dated 07/31/2008, Colors Used in Government<br />\nProcurement<br />\n2.3. United States Coast Guard Drawings and Publications. The following specifications and<br />\nstandards form a part of this specification to the extent specified herein.<br />\n2.3.1.United States Coast Guard Commandant Instruction (COMDTINST) M10360.3 (series),<br />\nCoatings and Color Manual<br />\n2.3.2.United States Coast Guard Technical Manual TP: 7148-512-A, dated08/24/2007, Standard<br />\nXA Vaneaxial Fan<br />\n2.3.3.Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022,<br />\nGeneral Requirements<br />\n2.3.4.Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3020), 2022,<br />\nOverhaul AC Electrical Motors<br />\n2.3.5.Specification Packaging and Labeling SP-PP&amp;M Rev D dated 6/6/11<br />\n2.4. Commercial Documents. The following documents form a part of this specification to the extent<br />\nspecified herein. The documents shall be the version listed by number and date from the<br />\nreferenced industry organization. Commercial documents may be listed in the Department of<br />\nDefense Index of Specifications and Standards (DODISS).<br />\n2.4.1.American Society for Testing &amp; Materials (ASTM) D3951-98, dated 2004, Standard<br />\nPractice for Commercial Packaging<br />\n2.4.2.International Standard Organization (ISO) 2953, 1999, Mechanical Vibration, Balancing<br />\nMachines, Description and Evaluation<br />\n2.4.3.Steel Structure Painting Council, SSPC-SP 3, dated 11/01/1982, Power Tool Cleaning<br />\n3. Background. This requirement is for the contractor to evaluate and repair the ventilation fan(s)<br />\n(vaneaxial) listed below Table 1 and Section 5. The fan units are designated as Supply Fan 1-22-2 and<br />\nSupply Fan 2-40-1.Table 1 - Ventilation Fan(s) for Overhaul<br />\nSystem / Fan Number Model Number Location<br />\nApproximate<br />\nDimensions/Weight<br />\nSl-22-2<br />\nAl-1/2 Class Z, 1,799<br />\nDry Stores (1-23-0-A)<br />\n20&quot; long x 17 .5&quot;<br />\nCFM 1.25 HP Diameter / 160 lbs.<br />\nS2-40-1 Al-1/2 Class Z, 1,450 Salvage Storeroom #4 20&quot; long x 17 .5&quot;<br />\nCFM 1.25 HP (2-36-0-A) Diameter / 160 lbs.<br />\n4. Tasks. The contractor shall provide services of which includes but may not limited to:<br />\n4.1. General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and<br />\nin this item, as applicable, during the performance of this availability. The requirements of this<br />\nwork apply to all work under the scope of this contract, whether explicitly stated in all following<br />\nwork items or not, and to all other work subsequently authorized by changes, modifications, or<br />\nextensions to the contract.<br />\n4.2. The Contractor shall submit a Receiving Inspection Report to the Coast Guard Contracting<br />\nOfficer (KO), Contracting Office&#39;s Representative (COR), and other listed Points of Contacts<br />\n(POCs) within 2 days of receiving the government furnished property (GFP). The report shall<br />\ndocument the make, part number, and/or model. This report shall also include digital<br />\nphotographic documentation of the crate and its contents.<br />\n4.2.1.It is assumed that the fan unit(s) will arrive in a re-usable container. In the event the<br />\ncontainer is deemed unusable the contractor shall state so as part of the inspection report and<br />\nprovide photo documentation.<br />\n4.3. Inspections, repair/overhaul and testing of the fan unit(s) shall be accomplished in accordance<br />\nwith the OEM procedures, specifications, references, and standard practices. The Contractor shall<br />\nconform to all requirements specified throughout this specification during performance of this<br />\ncontract. In the event of a conflict between the text of this specification and the references cited<br />\nherein, the text of this specification takes precedence. Nothing in this specification; however,<br />\nsupersedes applicable laws and regulations unless a specific exemption has been obtained.<br />\n4.3.1.The overhaul requirements described herein are considered the minimumnecessary and are<br />\nnot intended to replace any procedures, controls, examinations, or tests normally employed<br />\nby the Contractor to assure the quality of the product.<br />\n4 .3 .2. The overhaul of the fan unit( s) is intended to return the unit&#39;s performance and appearance<br />\nto a condition capable of functioning and performing in the same manner as an identical new<br />\nunit, as referred to as serviceable &quot;A&quot; condition.<br />\n4.4. Condition Found Report (CFR).<br />\n4.4.1.Preliminary disassembly and inspection of each fan unit shall be conducted in accordance<br />\nwith OEM procedures, specifications, references, and standard practices to determine the<br />\ntotal estimated cost to repair, including material, labor, testing, Preservation, Packing and<br />\nMarking (PP&amp;M) costs. A CFR shall be submitted to the KO, COR, and other listed POCs<br />\nwithin 5 days of the completion of the Receiving Inspection Report detailing the repair parts<br />\nrecommended for replacement and a total repair cost.<br />\n4.4.2. The CFR shall be submitted to the KO, COR, and other listed POCs for review and approval<br />\nprior to the start of any repair or order of any material. The Contractor shall also provide the<br />\nreplacement cost of an identical new fan unit for comparison to the overhaul cost. At a<br />\nminimum, mandatory replacement parts shall include all bearings, bushings, seals and<br />\ngaskets. All parts that are worn, have an improper fit and or damaged beyond the OEM<br />\ntolerances, shall be repaired or replaced as determined by the Contractor.<br />\n4.4.3.The detailed cost estimate shall contain the following as a minimum: the part number, NSN<br />\nand serial number of the fan unit, the contract number and deliveiy order number for the fan<br />\nunit, a listing of individual parts by part number, cost and quantity, a listing of labor hoursand labor rate to perform the overhaul, testing, and packaging, the cost of an identical new<br />\nfan unit.<br />\n4.4.4.Upon acceptance of the cost estimate and authorization to proceed by the KO, the Contractor<br />\nshall overhaul the fan unit in accordance with the OEM procedures, specifications,<br />\nreferences, standard practices and the references cited in section 2 of this specification.<br />\n4.4.5.The government reserves the right to dispose of the fan unit(s) if is Beyond Economic<br />\nRepair (BER). The contractor will dispose of the unit at a predetermined cost to the<br />\ngovernment. The contractor shall provide a scrap credit to the government or a price to<br />\ndiscard any fan unit BER.<br />\n4.4.5.1. The Coast Guard KO will determine the disposition of any fan unit delivered for<br />\noverhaul that is Beyond Economical Repair (BER).<br />\n4.4.5.2. If the fan unit is BER, the government reserves the right to purchase an identical<br />\nnew fan unit from the Contractor.<br />\n4.5. Fan- Overhaul. The Contractor shall accomplish the following tasks for each fan unit, using<br />\nreferences sited in Section 2 of this specification. The Contractor shall test, remove, overhaul,<br />\nand balance each fan unit.<br />\n4.5.1.Disassembly. The Contractor must disassemble the fan assembly for overhaul; follow the<br />\nsteps outlined in TP S9512-A3-MMA-010 Chapter 6. Prior to fan disassembly, the<br />\nContractor must measure air gap reading and bearing clearances. Submit a CFR. Take care<br />\nto match mark components to avoid the need for wheel rebalancing.<br />\n4.5.2.Cleaning. Clean the interior and exterior fan assembly surfaces, including housing, fan<br />\nblade, and end bell surf aces by first using suction, then with a soapy water solution, and<br />\nfallowed by a thorough rinsing of all metal surfaces. Ensure that there are no cleaning fluid<br />\nresidues or injurious effects on cleaned surfaces.<br />\n4 .5 .3 .Inspection and documentation. After surface preparation and before surface coating, visually<br />\ninspect the fan assembly surfaces including bearing surfaces for cracks, areas of distortion,<br />\nand deterioration.<br />\n4.5.4.Preservation. Prepare and coat the fan casing surfaces in using the system specified for<br />\n&quot;Machinery, Operating Temperatures Under 200-degree F, Unmachined Surfaces&quot; in<br />\nCOMDTINST Ml 0360.3, Appendix B (Cutter and Boat Interior Paint Systems). Select<br />\nfinish/topcoat color to match existing adjacent surfaces.<br />\n4.6. Motor - Overhaul. The Contractor shall accomplish the following tasks for each ventilation motor<br />\nassembly, using references sited in Section 2 of this specification.<br />\n4.6.1.Disassembly. The Contractor shall disassemble each ventilation fan motor from its fan.<br />\nDuring disassembly, ensure that each fan motor is properly marked to indicate the fan it was<br />\nremoved from. Remove end plates and rotor from motor frame. Remove existing motor<br />\nbearings and dispose of properly.<br />\n4.6.2.Inspection. The Contractor must disassemble, clean, inspect, and test all fan motor<br />\ncomponents in accordance with SFLC Std Spec 3020 paragraph 3.3. Submit CFR all<br />\nperformed inspections and testing, including but not limited to, initial visual conditions,<br />\ninitial insulation resistance tests, winding tests and final acceptance tests.<br />\n4.6.2.1. Rewind shall not be part of the overhaul process unless test results by the<br />\nContractor support rewind and is approved by the COR. High Potential tests shall only<br />\nbe performed for ventilation fan motors which require rewind.<br />\n4 .6 .3 .Re-assembly. Renew all motor bearings in accordance with SFLC Std Spec 3 02 0 paragraph<br />\n3.4.3. The Contractor must reassemble the motor in accordance with SFLC Std Spec 3020<br />\nparagraph 3.4.6. The Contractor must perform motor testing in with SFLC Std Spec 3020<br />\nparagraph 3 .5.<br />\n4.7. Fan and Motor Assembly Restoration. The Contractor shall reassemble each fan and motor<br />\nassembly using new gaskets and stainless-steel hardware; couple the fan to the motor assembly.<br />\nRenew all original data or label plates after completing external preservation. A separate labelplate made of similar material as the original label plate shall be attached to the fan unit stating<br />\nthe Contractor&#39;s name, contract number and date of overhaul.<br />\n4.8. Dynamic Balancing. The Contractor shall dynamically balance the rotating elements along with<br />\nassociated equipment as a unit (fan blade and motor installed and in casing), in accordance with<br />\nISO 2953. Submit a written balance report.<br />\n4.9. Operational Test- Post Repairs. After completion of work, the Contractor shall conduct an<br />\noperational test of each fan and motor assembly to prove satisfactory operating condition.<br />\nPerform an operational test of each overhauled ventilation fan, ensuring the fan operates in the<br />\ncorrect direction, with no excessive vibration or noise. Operate the fan assembly at its rated speed<br />\nfor 30 minutes. Measure and record the overhauled tube axial fan&#39;s CFM output to verify it is<br />\nwithin the manufacturer&#39;s rated tolerances. Submit a CFR.<br />\n4.10. Preservation, Packing, and Marking. The overhauled fan unit shall be delivered to the<br />\nCoast Guard completely assembled and in a ready to operate condition and configuration. The<br />\nContractor must return to the appropriate USCG representative via delivery or third-party<br />\nshipping. Contractor must provide any new gaskets for connections. The fan unit must be<br />\npackaged that protects it from moisture, rain, rust, corrosion, and vibration, which may constitute<br />\na standard export wooden box with plastic foam. The fan unit shall be completely sealed within a<br />\n6 mil (minimum) clear plastic bag, with sufficient units of desiccant to prevent moisture build up<br />\nand corrosion<br />\n5. Government Furnished Property.<br />\n5.1.Ventilation Fan (Vaneaxial), Model Al-1/2A4W5, QTY 2<br />\n6. Security Requirement. Base access is not required. If needed, contractor shall have a valid<br />\ngovernment issued ID (or driver&#39;s license) and show identification at the security gate. A Coast Guard<br />\nrepresentative from the cutter or Product Line will sponsor and escort vendor to the cutter. The<br />\ncontractor must coordinate any base access with the designated point of contact ahead of time to<br />\nensure administrative processing.<br />\n7. Place of Performance. Contractor&#39;s repair facility.<br />\n8. Period of Performance. 5-May-2025 to 5-June-2025<br />\n9. Points of Contact.<br />\n9 .1. USCG-SFLC-LREPL Asset Management: LTJG Mikael Axelsson, Mikael.J.Axelsson@uscg.mil,<br />\n(510) 493-1827<br />\n10. Contractor&#39;s Proposal.<br />\n10.1. Documentation. The Contractor must include at least the following in their proposal for<br />\nthis requirement: basic information (name, company name, contact details, the date, Unique<br />\nEntity ID), company overview and relevant qualifications, past performance, scope of work for<br />\nthe tasks and deliverables, project timeline, cost including a breakdown of the cost of each item<br />\nor service, terms and conditions, attachments/bid sheet, description of subcontractors (if any), and<br />\nsignature of the authorized person.<br />\n10.2. Proposal Evaluation Criteria. Award of this requirement shall be made to the vendor<br />\nwhose proposal offers the greatest value to the government regarding price, ability to meet all<br />\ntechnical requirements of the specification, and past performance.<br />\n11. Notes.<br />\n11. 1. Vaneaxial Fan Data - Supply Fan 1-22-2<br />\no Model: XA1-1/2A4W6, 1.25 HP, single speed, 3600 RPM for 440VAC/60HZ/3-<br />\nphase, steel housing and aluminum impeller, fixed pitch vaneaxial, motor shall<br />\nconform to IEEE-45 specifications and rated for 65-degree Celsius ambient operation.<br />\no Serial Number: N-1248 Item 16Vaneaxial Fan Data - Supply Fan 2-40-1<br />\n12. Photos.<br />\no Model: XA1-1/2A4W6, 1.25 HP, single speed, 3600 RPM for 440VAC/60HZ/3-<br />\nphase, steel housing and aluminum impeller, fixed pitch vaneaxial, motor shall<br />\nconform to IEEE-45 specifications and rated for 65-degree Celsius ambient operation.<br />\no Serial Number: SN14955-01-08<br />\n12.1. Motor data for Supply Fan 1-22-2.</p>","origin":"detail"},"contacts":[{"name":"BRENDEN COX","role":"primary","email":"BRENDEN.S.COX@USCG.MIL","phone":"12068315347"},{"name":"Isaiah C. Ragan","role":"secondary","email":"isaiah.c.ragan@uscg.mil","phone":"5104375429"}],"place_of_performance":{"zip":"99619","city":{"code":"40950","name":"Kodiak"},"state":{"code":"AK","name":"Alaska"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"naics_codes":["336611"],"award":null,"attachments":[{"resource_id":"b049318746a640689c81b8a575bf5451","name":"SOW_FanUnit-InspectRepair_CGCALEXHALEY.pdf","kind":"file","mime_type":".pdf","size_bytes":2781612,"posted_at":"2025-04-25T20:30:33.859Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b049318746a640689c81b8a575bf5451/download","mirrored":false}],"awards":[],"related":[{"key":"70Z08526RRJ001B00","latest_notice_id":"79adb3e9f10f4bceafdeca530cb99fdf","title":"TRS-3D /AN/SPS-75 Radar repairs/ overhaul services","solicitation_number":"70Z08526RRJ001B00","notice_type":"o","first_type":"o","first_posted":"2026-07-15","last_posted":"2026-11-19","notices":8,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"811210","psc":"J059","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"70Z08526Q39002B00","latest_notice_id":"c2c828ffaf9848a1a975736420ad55cf","title":"ACTUATOR,GOVERNOR","solicitation_number":"70Z08526Q39002B00","notice_type":"o","first_type":"o","first_posted":"2025-12-10","last_posted":"2025-12-10","notices":1,"due_at":"2026-12-19T16:00:00Z","due_date":"2026-12-19","closes_at":"2026-12-19T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"336611","psc":"2990","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 2990)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open":[{"key":"70ZU0227Q0001147","latest_notice_id":"2773e8d114d34eef8aea000151f1e601","title":"CGC NEAH BAY ANCHOR WINDLASS REPAIRS","solicitation_number":"70ZU0227Q0001147","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-25T16:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZU02","office_name":"CG-SEA-C22","naics":"336611","psc":"2030","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"N0040627Q0039","latest_notice_id":"8bbae1dcf0f84e03963c2c676fd943ec","title":"BOAT DAVIT OEM SERVICE","solicitation_number":"N0040627Q0039","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-25T20:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00406","office_name":"NAVSUP FLT LOG CTR PUGET SOUND","naics":"336611","psc":"J999","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"JPN","place_scope":"overseas","state_source":null,"state_evidence":"JPN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"N6264927RK003","latest_notice_id":"a5ed6a1c385f485792cc56d46933645f","title":"USNS CITY OF BISMARCK (T-EPF 9) VRA KR","solicitation_number":"N6264927RK003","notice_type":"o","first_type":"o","first_posted":"2026-11-20","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T01:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62649","office_name":"NAVSUP FLT LOG CTR YOKOSUKA","naics":"336611","psc":"J999","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"KOR","place_scope":"overseas","state_source":null,"state_evidence":"KOR","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":105,"indexable":false}