{"canonical":"https://sealedbidder.com/opportunities/70z085q12625","key":"70Z085Q12625","url":"https://sealedbidder.com/opportunities/70z085q12625","title":"USCGC HEALY OIL WASTE SYSTEM","solicitation_number":"70Z085Q12625","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-21T15:00:00Z","first_posted":"2025-04-16","last_posted":"2025-04-16","department":"HOMELAND SECURITY, DEPARTMENT OF","subagency":"US COAST GUARD","office":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"336611","psc":"J020","set_aside":"SBA","place_state":"WA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"53033","place_county_name":"King County","place_city":"5363000","place_city_name":"Seattle","winner":null,"award_amount":null,"publications":[{"notice_id":"3cd6f0c33e1d4525a780314a2d535ec7","title":"USCGC HEALY OIL WASTE SYSTEM","solicitation_number":"70Z085Q12625","notice_type":"k","base_type":"k","posted":"2025-04-16","posted_at":"2025-04-16T15:55:57.145Z","due_at":"2025-04-21T15:00:00Z","due_date":"2025-04-21","cancelled":false,"archived":true,"archive_date":"2025-04-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3cd6f0c33e1d4525a780314a2d535ec7/view","enriched":true,"history":[{"index":3,"title":"USCGC HEALY OIL WASTE SYSTEM","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T15:55:57.145Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3cd6f0c33e1d4525a780314a2d535ec7","solicitation_number":"70Z085Q12625"}]}],"latest_notice_id":"3cd6f0c33e1d4525a780314a2d535ec7","first_type":"k","notices":[{"dates":{"posted":"2025-04-16","posted_at":"2025-04-16T15:55:57.145Z","created_at":"2025-04-16T15:12:18.103Z","modified_at":"2025-04-22T03:55:49.162Z","response_deadline":{"raw":"2025-04-21T08:00:00-07:00","utc":"2025-04-21T15:00:00Z","date":"2025-04-21","time":"08:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3cd6f0c33e1d4525a780314a2d535ec7/view"},"naics":{"codes":["336611"],"primary":"336611"},"title":"USCGC HEALY OIL WASTE SYSTEM","agency":{"office":{"code":"70Z085","name":"SFLC PROCUREMENT BRANCH 2(00085)"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"organization_id":"100187922","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-21","archive_type":"auto_custom"},"history":[{"index":3,"title":"USCGC HEALY OIL WASTE SYSTEM","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-16T15:55:57.145Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3cd6f0c33e1d4525a780314a2d535ec7","solicitation_number":"70Z085Q12625"}],"contacts":[{"name":"BRENDEN COX","role":"primary","email":"BRENDEN.S.COX@USCG.MIL","phone":"12068315347"},{"name":"Isaiah C. Ragan","role":"secondary","email":"isaiah.c.ragan@uscg.mil","phone":"5104375429"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"3cd6f0c33e1d4525a780314a2d535ec7","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"3cd6f0c33e1d4525a780314a2d535ec7","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-17T10:46:05.516435869Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"65966986c78f19be392de033d5d7fe58c9fba80e99906afe9d2c5c0f0641f93d","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-17T10:46:05.516435869Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>STATEMENT OF WORK (SOW)</strong></p>\n\n<p><strong>FOR </strong></p>\n\n<p><strong>Oily Waste System (OWS) Separator Inspect and Repair</strong></p>\n\n<p></p>\n\n<p>During dry dock, an install was performed to modernize the Oily Water Separator system. The OWS starts up and is able to achieve an effluent below 15 ppm in recirculation mode. When the OWS attempts to shift to overboard, the flow sensor is indicating insufficient flow through the system to maintain a discharge overboard state, goes back into recirculation mode, and continues to attempt to discharge every 10 seconds.</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; OWS Model: Bilge Master E 500</p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li><strong>OBJECTIVE </strong></li>\n\t</ol>\n\t</li>\n</ol>\n\n<p>The goal is to supply CGC Healy with a service technician familiar in GEA oily waste system to troubleshoot the cause of insufficient pressure to discharge overboard:</p>\n\n<p></p>\n\n<ol>\n\t<li>The Contractor must provide the services of an OEM authorized/ licensed Tech Rep for the OWS to accomplish the following on site:\n\t<ol>\n\t\t<li>Inspect the OWS for root causes of insufficient flow to overboard discharge and repair to those issues.</li>\n\t\t<li>Submit CFRs for inspection and repair plan.</li>\n\t\t<li>Provide manufacturer&#39;s proprietary system/ equipment information, software, and tools.</li>\n\t\t<li>Assist with and ensure compliance with manufacturer&#39;s procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.</li>\n\t\t<li>&nbsp;Ensure the Tech Rep is an OEM Certified Representative for the system/equipment stated above and demonstrated on their r&eacute;sum&eacute;.&nbsp;</li>\n\t\t<li>Conduct an operational test post repairs to ensure the system is working in accordance with OEM parameters.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Site visit: </strong>contractors may conduct site visits at their own expense prior to conducting work.</p>\n\n<p></p>\n\n<p><strong>Planned Period of Performance</strong>: 5 - 9 May 2025, alternate date 2 - 6 June 2025</p>\n\n<p></p>\n\n<p><strong>Delivery Address:</strong> 1519 Alaskan Way S, Seattle, WA 98134</p>\n\n<p><strong>RDD/POP: 05-09 May 2025</strong></p>","text":"STATEMENT OF WORK (SOW)\n\nFOR\n\nOily Waste System (OWS) Separator Inspect and Repair\n\nDuring dry dock, an install was performed to modernize the Oily Water Separator system. The OWS starts up and is able to achieve an effluent below 15 ppm in recirculation mode. When the OWS attempts to shift to overboard, the flow sensor is indicating insufficient flow through the system to maintain a discharge overboard state, goes back into recirculation mode, and continues to attempt to discharge every 10 seconds.\n\nOWS Model: Bilge Master E 500\n\n•\n\n• OBJECTIVE\n\nThe goal is to supply CGC Healy with a service technician familiar in GEA oily waste system to troubleshoot the cause of insufficient pressure to discharge overboard:\n\n• The Contractor must provide the services of an OEM authorized/ licensed Tech Rep for the OWS to accomplish the following on site:\n\n• Inspect the OWS for root causes of insufficient flow to overboard discharge and repair to those issues.\n\n• Submit CFRs for inspection and repair plan.\n\n• Provide manufacturer's proprietary system/ equipment information, software, and tools.\n\n• Assist with and ensure compliance with manufacturer's procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.\n\n• Ensure the Tech Rep is an OEM Certified Representative for the system/equipment stated above and demonstrated on their résumé.\n\n• Conduct an operational test post repairs to ensure the system is working in accordance with OEM parameters.\n\nSite visit: contractors may conduct site visits at their own expense prior to conducting work.\n\nPlanned Period of Performance: 5 - 9 May 2025, alternate date 2 - 6 June 2025\n\nDelivery Address: 1519 Alaskan Way S, Seattle, WA 98134\n\nRDD/POP: 05-09 May 2025","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70Z085Q12625","place_of_performance":{"zip":"98134","city":{"code":"63000","name":"Seattle"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J020"}],"due_at":"2025-04-21T15:00:00Z","due_date":"2025-04-21","closes_at":"2025-04-21T15:00:00Z","awardable":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","state":"WA","county":"53033","county_name":"King County","city":"5363000","city_name":"Seattle","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-17T11:35:07.281678Z","principal_notice_id":"3cd6f0c33e1d4525a780314a2d535ec7","description":{"text":"STATEMENT OF WORK (SOW)\n\nFOR\n\nOily Waste System (OWS) Separator Inspect and Repair\n\nDuring dry dock, an install was performed to modernize the Oily Water Separator system. The OWS starts up and is able to achieve an effluent below 15 ppm in recirculation mode. When the OWS attempts to shift to overboard, the flow sensor is indicating insufficient flow through the system to maintain a discharge overboard state, goes back into recirculation mode, and continues to attempt to discharge every 10 seconds.\n\nOWS Model: Bilge Master E 500\n\n•\n\n• OBJECTIVE\n\nThe goal is to supply CGC Healy with a service technician familiar in GEA oily waste system to troubleshoot the cause of insufficient pressure to discharge overboard:\n\n• The Contractor must provide the services of an OEM authorized/ licensed Tech Rep for the OWS to accomplish the following on site:\n\n• Inspect the OWS for root causes of insufficient flow to overboard discharge and repair to those issues.\n\n• Submit CFRs for inspection and repair plan.\n\n• Provide manufacturer's proprietary system/ equipment information, software, and tools.\n\n• Assist with and ensure compliance with manufacturer's procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.\n\n• Ensure the Tech Rep is an OEM Certified Representative for the system/equipment stated above and demonstrated on their résumé.\n\n• Conduct an operational test post repairs to ensure the system is working in accordance with OEM parameters.\n\nSite visit: contractors may conduct site visits at their own expense prior to conducting work.\n\nPlanned Period of Performance: 5 - 9 May 2025, alternate date 2 - 6 June 2025\n\nDelivery Address: 1519 Alaskan Way S, Seattle, WA 98134\n\nRDD/POP: 05-09 May 2025","html":"<p><strong>STATEMENT OF WORK (SOW)</strong></p>\n\n<p><strong>FOR </strong></p>\n\n<p><strong>Oily Waste System (OWS) Separator Inspect and Repair</strong></p>\n\n<p></p>\n\n<p>During dry dock, an install was performed to modernize the Oily Water Separator system. The OWS starts up and is able to achieve an effluent below 15 ppm in recirculation mode. When the OWS attempts to shift to overboard, the flow sensor is indicating insufficient flow through the system to maintain a discharge overboard state, goes back into recirculation mode, and continues to attempt to discharge every 10 seconds.</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; OWS Model: Bilge Master E 500</p>\n\n<p></p>\n\n<ol>\n\t<li>\n\t<ol>\n\t\t<li><strong>OBJECTIVE </strong></li>\n\t</ol>\n\t</li>\n</ol>\n\n<p>The goal is to supply CGC Healy with a service technician familiar in GEA oily waste system to troubleshoot the cause of insufficient pressure to discharge overboard:</p>\n\n<p></p>\n\n<ol>\n\t<li>The Contractor must provide the services of an OEM authorized/ licensed Tech Rep for the OWS to accomplish the following on site:\n\t<ol>\n\t\t<li>Inspect the OWS for root causes of insufficient flow to overboard discharge and repair to those issues.</li>\n\t\t<li>Submit CFRs for inspection and repair plan.</li>\n\t\t<li>Provide manufacturer&#39;s proprietary system/ equipment information, software, and tools.</li>\n\t\t<li>Assist with and ensure compliance with manufacturer&#39;s procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.</li>\n\t\t<li>&nbsp;Ensure the Tech Rep is an OEM Certified Representative for the system/equipment stated above and demonstrated on their r&eacute;sum&eacute;.&nbsp;</li>\n\t\t<li>Conduct an operational test post repairs to ensure the system is working in accordance with OEM parameters.</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p></p>\n\n<p></p>\n\n<p><strong>Site visit: </strong>contractors may conduct site visits at their own expense prior to conducting work.</p>\n\n<p></p>\n\n<p><strong>Planned Period of Performance</strong>: 5 - 9 May 2025, alternate date 2 - 6 June 2025</p>\n\n<p></p>\n\n<p><strong>Delivery Address:</strong> 1519 Alaskan Way S, Seattle, WA 98134</p>\n\n<p><strong>RDD/POP: 05-09 May 2025</strong></p>","origin":"detail"},"contacts":[{"name":"BRENDEN COX","role":"primary","email":"BRENDEN.S.COX@USCG.MIL","phone":"12068315347"},{"name":"Isaiah C. Ragan","role":"secondary","email":"isaiah.c.ragan@uscg.mil","phone":"5104375429"}],"place_of_performance":{"zip":"98134","city":{"code":"63000","name":"Seattle"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"naics_codes":["336611"],"award":null,"attachments":[{"resource_id":"96ddde2448a543998f0395f30e101b1b","name":"SOW_OWS.docx","kind":"file","mime_type":".docx","size_bytes":30262,"posted_at":"2025-04-16T15:55:57.145Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/96ddde2448a543998f0395f30e101b1b/download","mirrored":false}],"awards":[],"related":[{"key":"70Z08526RRJ001B00","latest_notice_id":"79adb3e9f10f4bceafdeca530cb99fdf","title":"TRS-3D /AN/SPS-75 Radar repairs/ overhaul services","solicitation_number":"70Z08526RRJ001B00","notice_type":"o","first_type":"o","first_posted":"2026-07-15","last_posted":"2026-11-19","notices":8,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"811210","psc":"J059","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"70Z08526Q39002B00","latest_notice_id":"c2c828ffaf9848a1a975736420ad55cf","title":"ACTUATOR,GOVERNOR","solicitation_number":"70Z08526Q39002B00","notice_type":"o","first_type":"o","first_posted":"2025-12-10","last_posted":"2025-12-10","notices":1,"due_at":"2026-12-19T16:00:00Z","due_date":"2026-12-19","closes_at":"2026-12-19T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"336611","psc":"2990","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 2990)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open":[{"key":"N4523A27Q1005","latest_notice_id":"81d2591e008d4f70b55d402404fa9e71","title":"Maintenance, Repair, and Preservation of 60DS1701","solicitation_number":"N4523A27Q1005","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T22:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N4523A","office_name":"PUGET SOUND NAVAL SHIPYARD IMF","naics":"336611","psc":"J019","set_aside":null,"state":"WA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"70ZU027ILREP1113","latest_notice_id":"69763ae38fbf45afbd8469b581d31f8f","title":"USCGC HEALY Integrated Power Plant Support Services Contract Fiscal Year 2028-2033","solicitation_number":"70ZU027ILREP1113","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-16","notices":4,"due_at":"2026-11-30T01:00:00Z","due_date":"2026-11-29","closes_at":"2026-11-30T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZU02","office_name":"CG-SEA-C22","naics":"336611","psc":"J999","set_aside":null,"state":"WA","county":"53033","county_name":"King County","city":"5363000","city_name":"Seattle","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"70Z08526QLREP0026","latest_notice_id":"879af80d060c4ae9b72f1e0077416d12","title":"Dockside (DS) – USCGC STORIS Fiscal Year 2027","solicitation_number":"70Z08526QLREP0026","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-21T20:00:00Z","due_date":"2026-12-21","closes_at":"2026-12-21T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZU02","office_name":"CG-SEA-C22","naics":"336611","psc":"J999","set_aside":"SBA","state":"WA","county":"53033","county_name":"King County","city":"5363000","city_name":"Seattle","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":104,"indexable":false}