{"canonical":"https://sealedbidder.com/opportunities/70z08526q026671","key":"70Z08526Q026671","url":"https://sealedbidder.com/opportunities/70z08526q026671","title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","solicitation_number":"70Z08526Q026671","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-24T15:00:00Z","first_posted":"2026-07-15","last_posted":"2026-07-20","department":"HOMELAND SECURITY, DEPARTMENT OF","subagency":"US COAST GUARD","office":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"33661","psc":"J020","set_aside":"SBA","place_state":"CA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"06073","place_county_name":"San Diego County","place_city":"0666000","place_city_name":"San Diego","winner":null,"award_amount":null,"publications":[{"notice_id":"116de0e8724d4cd995cc7c4db5c1fe1b","title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","solicitation_number":"70Z08526Q026671","notice_type":"o","base_type":"o","posted":"2026-07-15","posted_at":"2026-07-15T19:21:16.830Z","due_at":"2026-07-21T15:00:00Z","due_date":"2026-07-21","cancelled":false,"archived":true,"archive_date":"2026-08-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/116de0e8724d4cd995cc7c4db5c1fe1b/view","enriched":true,"history":[{"index":3,"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T19:24:17.730Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9256ab77e5c84ff78c961e265f761bb6","solicitation_number":"70Z08526Q026671","parent_opportunity_id":"116de0e8724d4cd995cc7c4db5c1fe1b"},{"index":1,"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T19:21:16.830Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"116de0e8724d4cd995cc7c4db5c1fe1b","solicitation_number":"70Z08526Q026671"}]},{"notice_id":"9256ab77e5c84ff78c961e265f761bb6","title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","solicitation_number":"70Z08526Q026671","notice_type":"o","base_type":"o","posted":"2026-07-15","posted_at":"2026-07-15T19:24:17.730Z","due_at":"2026-07-21T15:00:00Z","due_date":"2026-07-21","cancelled":false,"archived":true,"archive_date":"2026-08-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9256ab77e5c84ff78c961e265f761bb6/view","enriched":true,"history":[{"index":3,"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T19:24:17.730Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9256ab77e5c84ff78c961e265f761bb6","solicitation_number":"70Z08526Q026671","parent_opportunity_id":"116de0e8724d4cd995cc7c4db5c1fe1b"},{"index":1,"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T19:21:16.830Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"116de0e8724d4cd995cc7c4db5c1fe1b","solicitation_number":"70Z08526Q026671"}]},{"notice_id":"30c26d1d64774d7797ef552366624193","title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","solicitation_number":"70Z08526Q026671","notice_type":"k","base_type":"k","posted":"2026-07-20","posted_at":"2026-07-20T21:47:24.549Z","due_at":"2026-07-24T15:00:00Z","due_date":"2026-07-24","cancelled":false,"archived":true,"archive_date":"2026-08-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/30c26d1d64774d7797ef552366624193/view","enriched":true,"history":[{"index":3,"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-20T21:47:24.549Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"30c26d1d64774d7797ef552366624193","solicitation_number":"70Z08526Q026671","parent_opportunity_id":"e0e4e99377394f37af870966ef71026b"},{"index":1,"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-20T21:44:55.747Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"e0e4e99377394f37af870966ef71026b","solicitation_number":"70Z08526Q026671"}]},{"notice_id":"e0e4e99377394f37af870966ef71026b","title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","solicitation_number":"70Z08526Q026671","notice_type":"k","base_type":"k","posted":"2026-07-20","posted_at":"2026-07-20T21:44:55.747Z","due_at":"2026-07-24T15:00:00Z","due_date":"2026-07-24","cancelled":false,"archived":true,"archive_date":"2026-08-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e0e4e99377394f37af870966ef71026b/view","enriched":true,"history":[{"index":3,"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-20T21:47:24.549Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"30c26d1d64774d7797ef552366624193","solicitation_number":"70Z08526Q026671","parent_opportunity_id":"e0e4e99377394f37af870966ef71026b"},{"index":1,"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-20T21:44:55.747Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"e0e4e99377394f37af870966ef71026b","solicitation_number":"70Z08526Q026671"}]}],"latest_notice_id":"e0e4e99377394f37af870966ef71026b","first_type":"o","notices":[{"dates":{"posted":"2026-07-15","posted_at":"2026-07-15T19:21:16.830Z","created_at":"2026-07-15T19:13:32.171Z","modified_at":"2026-08-05T05:06:25.107Z","response_deadline":{"raw":"2026-07-21T08:00:00-07:00","utc":"2026-07-21T15:00:00Z","date":"2026-07-21","time":"08:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/116de0e8724d4cd995cc7c4db5c1fe1b/view"},"naics":{"codes":["336611"],"primary":"336611"},"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","agency":{"office":{"code":"70Z085","name":"SFLC PROCUREMENT BRANCH 2(00085)"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"organization_id":"100187922","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-05","archive_type":"auto15"},"history":[{"index":3,"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T19:24:17.730Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9256ab77e5c84ff78c961e265f761bb6","solicitation_number":"70Z08526Q026671","parent_opportunity_id":"116de0e8724d4cd995cc7c4db5c1fe1b"},{"index":1,"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T19:21:16.830Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"116de0e8724d4cd995cc7c4db5c1fe1b","solicitation_number":"70Z08526Q026671"}],"contacts":[{"name":"ULISES BALMACEDA","role":"primary","email":"Ulises.O.Balmaceda@uscg.mil","phone":"2068200307"},{"name":"Lindsay Mongiovi","role":"secondary","email":"lindsay.n.mongiovi@uscg.mil","phone":"5716086752"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"116de0e8724d4cd995cc7c4db5c1fe1b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"116de0e8724d4cd995cc7c4db5c1fe1b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T02:34:45.047883529Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"66e0b40d569424076230e16cf7a7b66404a49d1274ebdbd11796c1936b7df23d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T02:34:45.047883529Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p><strong>General Requirements</strong>&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p><strong>1. SCOPE</strong> &nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>1.1&nbsp;<u>Intent</u>. This standard specification invokes general requirements for conducting vessel repairs performed by commercial contractors at a Commercial facility for Coast Guard vessels.   &nbsp;</p>\n\n<p>  &nbsp;<br />\n<strong>2. REFERENCES</strong>&nbsp;</p>\n\n<p>  &nbsp;<br />\n<strong>COAST GUARD DRAWINGS</strong>&nbsp;</p>\n\n<p>  &nbsp;<br />\nNone.&nbsp;</p>\n\n<p>  &nbsp;<br />\n<strong>COAST GUARD PUBLICATIONS</strong>   &nbsp;</p>\n\n<p>Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p><strong>OTHER REFERENCES</strong>&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>None.&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p><strong>3. REQUIREMENTS</strong>&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>3.1&nbsp;<u>General</u>. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and in this item, as applicable, during the performance of this availability. The requirements of this WI apply to all work under the scope of this contract, whether explicitly stated in all following work items or not, and to all other work subsequently authorized by changes, modifications, or extensions to the contract.&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>3.2 <u>Period of Performance</u>. The period of performance for this work is 31JUL26 to 04AUG26.&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>3.3 <u>Location</u>. The Contractor must perform the work while the USCGC BERTHOLF is alongside the pier&nbsp;at:</p>\n\n<p>San Diego B Street Pier</p>\n\n<p>San Diego CA 92132</p>\n\n<p></p>\n\n<p> </p>\n\n<p><em>S26_093_51200_MLA_0726_750</em></p>\n\n<ol>\n\t<li><strong>ITEM 1: Vaneaxial Fan, Renew</strong></li>\n</ol>\n\n<p><strong>1. SCOPE</strong></p>\n\n<p>1.1 <u>Intent</u>.&nbsp; This work item describes the requirements for the Contractor to renew the ventilation fan(s) listed in Table 1.</p>\n\n<p><strong>TABLE 1 &ndash; Ventilation Fans for renewal</strong></p>\n\n<p><strong>SYSTEM / FAN NUMBER</strong></p>\n\n<p><strong>model number</strong></p>\n\n<p><strong>LOCATION</strong></p>\n\n<p><strong>dimension / APPROX. WEIGHTS</strong></p>\n\n<p><strong>coast guard DRAWING </strong></p>\n\n<p>SS-64 / 02-48-1</p>\n\n<p>XA20A4W5</p>\n\n<p>Fan Space</p>\n\n<p>(02-46-1-Q)</p>\n\n<p>48 in. x 39 in.</p>\n\n<p>&nbsp;1250 lbs.</p>\n\n<p>750-WSML-512-049</p>\n\n<p>1.2 <u>Government-furnished property</u>.</p>\n\n<p><strong>MTI</strong></p>\n\n<p><strong>ITEM DESCRIPTION</strong></p>\n\n<p><strong>NSN/PN</strong></p>\n\n<p><strong>QTY</strong></p>\n\n<p><strong>ESTIMATED COST<br />\n($/UNIT)</strong></p>\n\n<p>N</p>\n\n<p>Fan, Vaneaxial</p>\n\n<p>4140-01-603-5356 / XA20A4W5</p>\n\n<p>1 EA</p>\n\n<p></p>\n\n<p><strong>2. REFERENCES</strong></p>\n\n<p><strong>Coast Guard Drawings</strong></p>\n\n<p>Coast Guard Drawing 418A-WMSL-100-001, Rev C, General Arrangements</p>\n\n<p>Coast Guard Drawing 418A-WMSL-512-001, Rev E, HVAC System Diagram</p>\n\n<p>Coast Guard Drawing 418A-WMSL-801-002, Rev (-), Booklet of General Plans</p>\n\n<p>Coast Guard Drawing 750-WMSL-512-049, Rev C, Vent Arr Stack Unit 4320</p>\n\n<p>Coast Guard Drawing 750-WMSL-512-534, Rev D, HVAC Equipment List</p>\n\n<p><strong>Coast Guard Publications</strong></p>\n\n<p>Coast Guard Technical Publication (TP) 7148, SWBS 512, June 2025, Standard XA Vaneaxial Fan</p>\n\n<p>Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements</p>\n\n<p>Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes</p>\n\n<p>Surface Forces Logistics Center Standard Specification 3020 (SFLC Std Spec 3020), 2022, Overhaul AC Electric Motors</p>\n\n<p>Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3041), 2022, Shipboard Electrical Cable Test</p>\n\n<p>Surface Forces Logistics Center Standard Specification 3042 (SFLC Std Spec 3042),&nbsp;2022, Shipboard Electrical Cable Removal, Relocation, Splice, Repair, And Installation&nbsp;</p>\n\n<p>Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures</p>\n\n<p><strong>Other References</strong></p>\n\n<p>None.</p>\n\n<p><strong>3. REQUIREMENTS</strong></p>\n\n<p>3.1 <u>General</u>.</p>\n\n<p>3.1.1 <u>CIR</u>.</p>\n\n<p>None.</p>\n\n<p>3.1.2 <u>Technical Representative</u>.&nbsp;</p>\n\n<p>Not applicable.</p>\n\n<p>3.1.3 <u>Protective measures</u>. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).</p>\n\n<p>3.1.4 <u>Interferences</u>. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, (Interferences). Known interferences include, but are not limited to the following:</p>\n\n<ul>\n\t<li>Ventilation screens</li>\n\t<li>Ventilation ducting</li>\n\t<li>Piping</li>\n\t<li>Wiring</li>\n\t<li>Fan mounting and fan supports</li>\n\t<li>Electrical cables</li>\n</ul>\n\n<p>3.1.5 <u>Disposal</u>. The Contractor must dispose of the removed vaneaxial fan and new fan shipping materials in compliance with applicable local, state, and Federal regulations.</p>\n\n<p>3.1.6 <u>Elevated surfaces</u>. The Contractor must, in accordance with CFR Title 29, Part 1915, Subpart E, erect suitable staging or scaffolding, as required, to facilitate work. The Contractor must provide all lifting equipment to remove and re-install the vaneaxial fan assembly in Table 1.</p>\n\n<p>3.1.7 Small boat. Ship&rsquo;s force will remove the small boat located in the Dual Point Davit.</p>\n\n<p><strong>NOTE</strong></p>\n\n<p><strong>Coast Guard personnel will operate all shipboard machinery and equipment.</strong></p>\n\n<p>3.2 <u>Operational test, initial</u>. Prior to commencement of work, the Contractor must witness Coast Guard personnel perform an initial operational test of all items or shipboard devices to be disturbed, used, repaired, or altered, to demonstrate existing operational condition. Submit a CFR</p>\n\n<p>3.3 <u>Temporary ventilation</u>. Not required.</p>\n\n<p>3.4 <u>Vaneaxial fan assembly removal</u>. The Contractor must remove vaneaxial fan assemblies listed in Table 1 from their ventilation ducts. The Contractor must temporarily support the ventilation duct on each side of removed vaneaxial fan assembly.</p>\n\n<p><strong>CAUTION</strong></p>\n\n<p><strong>Multiple sources of power may be present.&nbsp; Ensure that all power sources are secured and tagged prior to the start of any work.&nbsp; All auxiliary circuits in the machine must be de-energized.</strong></p>\n\n<p>3.4.1 Ship Forces will disconnect electric cables to vaneaxial fan assembly in accordance with SFLC Std Spec 3042. Pull back cables and temporarily insulate cable ends for safety. Record wiring information for later re-connection.</p>\n\n<p>3.4.2 The Contractor must clean and inspect three feet of ductwork connected to inlet and outlet of the removed fan. Submit a CFR with inspection results.</p>\n\n<p>3.4.3 The Contractor must test cables between electric motor and control equipment in accordance with SFLC Std Spec 3041. Submit CFR with test results.</p>\n\n<p>3.5 <u>Vaneaxial fan installation</u>. The Contractor must install <u>vaneaxial fan assembly provided as GFM. Follow the installation procedures outlined in CG Tech Pub 7148 Chapter 8. Submit pre-installation testing results via CFR. </u></p>\n\n<p><u>3.5.1 </u>Secure ducting flanges to fan flanges using new stainless steel cap screws, washers, and locknuts.</p>\n\n<p>3.5.2 Restore all ventilation ductwork and ventilation screen to original configuration as shown on Coast Guard Drawing <u>references listed in Section 2</u>. Attach screen using new stainless steel hardware.</p>\n\n<p>3.5.3 Re-connect cables with previously recorded information and firmly secure the cables.&nbsp; Test cables in accordance with SFLC Std Spec 3042 and re-connect the cables with previously recorded wiring information in accordance with SFLC Std Spec 3041.</p>\n\n<p>3.6 <u>Verification</u>.&nbsp; Prior to re-energization, a final closeout inspection must be performed in the presence of the Coast Guard Inspector. Follow the Checkout Procedures outlined in CG Tech Pub 7148. The Contractor must submit a signed completed copy of the inspection checklist via CFR.</p>\n\n<p><strong>CAUTION</strong></p>\n\n<p><strong>To prevent damage to multi-speed motors with possible opposite shaft rotation in different speeds, always start motor directly from off and never shift directly from one speed to another until direction of rotation checks are completed satisfactorily and shaft completely stopped in all speeds.&nbsp; Ensure shaft is not rotating (completely stopped) prior to any restarting of the motor.</strong></p>\n\n<p><strong>NOTE</strong></p>\n\n<p><strong>Coast Guard personnel will operate all shipboard machinery and equipment.</strong></p>\n\n<p>3.7 <u>Operational test, post repairs</u>. After completion of work, the Contractor must thoroughly test, in the presence of the Coast Guard Inspector, and demonstrate all items or shipboard devices that have been disturbed, used, repaired, altered, or installed to be in satisfactory operating condition. Verify that vaneaxial fan assembly is rotating in the proper direction in all speeds. Verify that Vaneaxial Fan Assembly is quiet and vibration free. Operate the fan assembly at its rated speed for 30 minutes. Record current and voltage during the test. Submit a CFR.</p>\n\n<p><strong>4. NOTES</strong></p>\n\n<p>This section is not applicable to this work item.</p>","text":"General Requirements\n\n1. SCOPE\n\n1.1 Intent. This standard specification invokes general requirements for conducting vessel repairs performed by commercial contractors at a Commercial facility for Coast Guard vessels.\n\n2. REFERENCES\n\nCOAST GUARD DRAWINGS\n\nNone.\n\nCOAST GUARD PUBLICATIONS\n\nSurface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements\n\nOTHER REFERENCES\n\nNone.\n\n3. REQUIREMENTS\n\n3.1 General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and in this item, as applicable, during the performance of this availability. The requirements of this WI apply to all work under the scope of this contract, whether explicitly stated in all following work items or not, and to all other work subsequently authorized by changes, modifications, or extensions to the contract.\n\n3.2 Period of Performance. The period of performance for this work is 31JUL26 to 04AUG26.\n\n3.3 Location. The Contractor must perform the work while the USCGC BERTHOLF is alongside the pier at:\n\nSan Diego B Street Pier\n\nSan Diego CA 92132\n\nS26_093_51200_MLA_0726_750\n\n• ITEM 1: Vaneaxial Fan, Renew\n\n1. SCOPE\n\n1.1 Intent. This work item describes the requirements for the Contractor to renew the ventilation fan(s) listed in Table 1.\n\nTABLE 1 – Ventilation Fans for renewal\n\nSYSTEM / FAN NUMBER\n\nmodel number\n\nLOCATION\n\ndimension / APPROX. WEIGHTS\n\ncoast guard DRAWING\n\nSS-64 / 02-48-1\n\nXA20A4W5\n\nFan Space\n\n(02-46-1-Q)\n\n48 in. x 39 in.\n\n1250 lbs.\n\n750-WSML-512-049\n\n1.2 Government-furnished property.\n\nMTI\n\nITEM DESCRIPTION\n\nNSN/PN\n\nQTY\n\nESTIMATED COST\n\n($/UNIT)\n\nN\n\nFan, Vaneaxial\n\n4140-01-603-5356 / XA20A4W5\n\n1 EA\n\n2. REFERENCES\n\nCoast Guard Drawings\n\nCoast Guard Drawing 418A-WMSL-100-001, Rev C, General Arrangements\n\nCoast Guard Drawing 418A-WMSL-512-001, Rev E, HVAC System Diagram\n\nCoast Guard Drawing 418A-WMSL-801-002, Rev (-), Booklet of General Plans\n\nCoast Guard Drawing 750-WMSL-512-049, Rev C, Vent Arr Stack Unit 4320\n\nCoast Guard Drawing 750-WMSL-512-534, Rev D, HVAC Equipment List\n\nCoast Guard Publications\n\nCoast Guard Technical Publication (TP) 7148, SWBS 512, June 2025, Standard XA Vaneaxial Fan\n\nSurface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements\n\nSurface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes\n\nSurface Forces Logistics Center Standard Specification 3020 (SFLC Std Spec 3020), 2022, Overhaul AC Electric Motors\n\nSurface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3041), 2022, Shipboard Electrical Cable Test\n\nSurface Forces Logistics Center Standard Specification 3042 (SFLC Std Spec 3042), 2022, Shipboard Electrical Cable Removal, Relocation, Splice, Repair, And Installation\n\nSurface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures\n\nOther References\n\nNone.\n\n3. REQUIREMENTS\n\n3.1 General.\n\n3.1.1 CIR.\n\nNone.\n\n3.1.2 Technical Representative.\n\nNot applicable.\n\n3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).\n\n3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, (Interferences). Known interferences include, but are not limited to the following:\n\n• Ventilation screens\n\n• Ventilation ducting\n\n• Piping\n\n• Wiring\n\n• Fan mounting and fan supports\n\n• Electrical cables\n\n3.1.5 Disposal. The Contractor must dispose of the removed vaneaxial fan and new fan shipping materials in compliance with applicable local, state, and Federal regulations.\n\n3.1.6 Elevated surfaces. The Contractor must, in accordance with CFR Title 29, Part 1915, Subpart E, erect suitable staging or scaffolding, as required, to facilitate work. The Contractor must provide all lifting equipment to remove and re-install the vaneaxial fan assembly in Table 1.\n\n3.1.7 Small boat. Ship’s force will remove the small boat located in the Dual Point Davit.\n\nNOTE\n\nCoast Guard personnel will operate all shipboard machinery and equipment.\n\n3.2 Operational test, initial. Prior to commencement of work, the Contractor must witness Coast Guard personnel perform an initial operational test of all items or shipboard devices to be disturbed, used, repaired, or altered, to demonstrate existing operational condition. Submit a CFR\n\n3.3 Temporary ventilation. Not required.\n\n3.4 Vaneaxial fan assembly removal. The Contractor must remove vaneaxial fan assemblies listed in Table 1 from their ventilation ducts. The Contractor must temporarily support the ventilation duct on each side of removed vaneaxial fan assembly.\n\nCAUTION\n\nMultiple sources of power may be present. Ensure that all power sources are secured and tagged prior to the start of any work. All auxiliary circuits in the machine must be de-energized.\n\n3.4.1 Ship Forces will disconnect electric cables to vaneaxial fan assembly in accordance with SFLC Std Spec 3042. Pull back cables and temporarily insulate cable ends for safety. Record wiring information for later re-connection.\n\n3.4.2 The Contractor must clean and inspect three feet of ductwork connected to inlet and outlet of the removed fan. Submit a CFR with inspection results.\n\n3.4.3 The Contractor must test cables between electric motor and control equipment in accordance with SFLC Std Spec 3041. Submit CFR with test results.\n\n3.5 Vaneaxial fan installation. The Contractor must install vaneaxial fan assembly provided as GFM. Follow the installation procedures outlined in CG Tech Pub 7148 Chapter 8. Submit pre-installation testing results via CFR.\n\n3.5.1 Secure ducting flanges to fan flanges using new stainless steel cap screws, washers, and locknuts.\n\n3.5.2 Restore all ventilation ductwork and ventilation screen to original configuration as shown on Coast Guard Drawing references listed in Section 2. Attach screen using new stainless steel hardware.\n\n3.5.3 Re-connect cables with previously recorded information and firmly secure the cables. Test cables in accordance with SFLC Std Spec 3042 and re-connect the cables with previously recorded wiring information in accordance with SFLC Std Spec 3041.\n\n3.6 Verification. Prior to re-energization, a final closeout inspection must be performed in the presence of the Coast Guard Inspector. Follow the Checkout Procedures outlined in CG Tech Pub 7148. The Contractor must submit a signed completed copy of the inspection checklist via CFR.\n\nCAUTION\n\nTo prevent damage to multi-speed motors with possible opposite shaft rotation in different speeds, always start motor directly from off and never shift directly from one speed to another until direction of rotation checks are completed satisfactorily and shaft completely stopped in all speeds. Ensure shaft is not rotating (completely stopped) prior to any restarting of the motor.\n\nNOTE\n\nCoast Guard personnel will operate all shipboard machinery and equipment.\n\n3.7 Operational test, post repairs. After completion of work, the Contractor must thoroughly test, in the presence of the Coast Guard Inspector, and demonstrate all items or shipboard devices that have been disturbed, used, repaired, altered, or installed to be in satisfactory operating condition. Verify that vaneaxial fan assembly is rotating in the proper direction in all speeds. Verify that Vaneaxial Fan Assembly is quiet and vibration free. Operate the fan assembly at its rated speed for 30 minutes. Record current and voltage during the test. Submit a CFR.\n\n4. NOTES\n\nThis section is not applicable to this work item.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"70Z08526Q026671","place_of_performance":{"zip":"92132","city":{"code":"66000","name":"San Diego"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J020"},{"dates":{"posted":"2026-07-15","posted_at":"2026-07-15T19:24:17.730Z","created_at":"2026-07-15T19:22:01.923Z","modified_at":"2026-08-05T05:06:25.107Z","response_deadline":{"raw":"2026-07-21T08:00:00-07:00","utc":"2026-07-21T15:00:00Z","date":"2026-07-21","time":"08:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9256ab77e5c84ff78c961e265f761bb6/view"},"naics":{"codes":["336611"],"primary":"336611"},"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","agency":{"office":{"code":"70Z085","name":"SFLC PROCUREMENT BRANCH 2(00085)"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"organization_id":"100187922","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-05","archive_type":"auto15"},"history":[{"index":3,"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T19:24:17.730Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9256ab77e5c84ff78c961e265f761bb6","solicitation_number":"70Z08526Q026671","parent_opportunity_id":"116de0e8724d4cd995cc7c4db5c1fe1b"},{"index":1,"title":"USCGC BERTHOLF VANEAXIAL FAN SERVICE","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-15T19:21:16.830Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"116de0e8724d4cd995cc7c4db5c1fe1b","solicitation_number":"70Z08526Q026671"}],"contacts":[{"name":"DONNA O'NEAL","role":"primary","email":"Donna.J.O'Neal@uscg.mil","phone":"5103931145"},{"name":"Lindsay Mongiovi","role":"secondary","email":"lindsay.n.mongiovi@uscg.mil","phone":"5716086752"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"9256ab77e5c84ff78c961e265f761bb6","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"116de0e8724d4cd995cc7c4db5c1fe1b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T02:55:41.780768151Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"7f0212140a3d691f45a8286fa5eeaff178377d5f50225c6d50cdf91f8bdcdde1","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T02:55:41.780768151Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p><strong>General Requirements</strong>&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p><strong>1. SCOPE</strong> &nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>1.1&nbsp;<u>Intent</u>. This standard specification invokes general requirements for conducting vessel repairs performed by commercial contractors at a Commercial facility for Coast Guard vessels.   &nbsp;</p>\n\n<p>  &nbsp;<br />\n<strong>2. REFERENCES</strong>&nbsp;</p>\n\n<p>  &nbsp;<br />\n<strong>COAST GUARD DRAWINGS</strong>&nbsp;</p>\n\n<p>  &nbsp;<br />\nNone.&nbsp;</p>\n\n<p>  &nbsp;<br />\n<strong>COAST GUARD PUBLICATIONS</strong>   &nbsp;</p>\n\n<p>Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p><strong>OTHER REFERENCES</strong>&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>None.&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p><strong>3. REQUIREMENTS</strong>&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>3.1&nbsp;<u>General</u>. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and in this item, as applicable, during the performance of this availability. The requirements of this WI apply to all work under the scope of this contract, whether explicitly stated in all following work items or not, and to all other work subsequently authorized by changes, modifications, or extensions to the contract.&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>3.2 <u>Period of Performance</u>. The period of performance for this work is 31JUL26 to 04AUG26.&nbsp;</p>\n\n<p>  &nbsp;</p>\n\n<p>3.3 <u>Location</u>. The Contractor must perform the work while the USCGC BERTHOLF is alongside the pier&nbsp;at:</p>\n\n<p>San Diego B Street Pier</p>\n\n<p>San Diego CA 92132</p>\n\n<p></p>\n\n<p> </p>\n\n<p><em>S26_093_51200_MLA_0726_750</em></p>\n\n<ol>\n\t<li><strong>ITEM 1: Vaneaxial Fan, Renew</strong></li>\n</ol>\n\n<p><strong>1. SCOPE</strong></p>\n\n<p>1.1 <u>Intent</u>.&nbsp; This work item describes the requirements for the Contractor to renew the ventilation fan(s) listed in Table 1.</p>\n\n<p><strong>TABLE 1 &ndash; Ventilation Fans for renewal</strong></p>\n\n<p><strong>SYSTEM / FAN NUMBER</strong></p>\n\n<p><strong>model number</strong></p>\n\n<p><strong>LOCATION</strong></p>\n\n<p><strong>dimension / APPROX. WEIGHTS</strong></p>\n\n<p><strong>coast guard DRAWING </strong></p>\n\n<p>SS-64 / 02-48-1</p>\n\n<p>XA20A4W5</p>\n\n<p>Fan Space</p>\n\n<p>(02-46-1-Q)</p>\n\n<p>48 in. x 39 in.</p>\n\n<p>&nbsp;1250 lbs.</p>\n\n<p>750-WSML-512-049</p>\n\n<p>1.2 <u>Government-furnished property</u>.</p>\n\n<p><strong>MTI</strong></p>\n\n<p><strong>ITEM DESCRIPTION</strong></p>\n\n<p><strong>NSN/PN</strong></p>\n\n<p><strong>QTY</strong></p>\n\n<p><strong>ESTIMATED COST<br />\n($/UNIT)</strong></p>\n\n<p>N</p>\n\n<p>Fan, Vaneaxial</p>\n\n<p>4140-01-603-5356 / XA20A4W5</p>\n\n<p>1 EA</p>\n\n<p></p>\n\n<p><strong>2. REFERENCES</strong></p>\n\n<p><strong>Coast Guard Drawings</strong></p>\n\n<p>Coast Guard Drawing 418A-WMSL-100-001, Rev C, General Arrangements</p>\n\n<p>Coast Guard Drawing 418A-WMSL-512-001, Rev E, HVAC System Diagram</p>\n\n<p>Coast Guard Drawing 418A-WMSL-801-002, Rev (-), Booklet of General Plans</p>\n\n<p>Coast Guard Drawing 750-WMSL-512-049, Rev C, Vent Arr Stack Unit 4320</p>\n\n<p>Coast Guard Drawing 750-WMSL-512-534, Rev D, HVAC Equipment List</p>\n\n<p><strong>Coast Guard Publications</strong></p>\n\n<p>Coast Guard Technical Publication (TP) 7148, SWBS 512, June 2025, Standard XA Vaneaxial Fan</p>\n\n<p>Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements</p>\n\n<p>Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes</p>\n\n<p>Surface Forces Logistics Center Standard Specification 3020 (SFLC Std Spec 3020), 2022, Overhaul AC Electric Motors</p>\n\n<p>Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3041), 2022, Shipboard Electrical Cable Test</p>\n\n<p>Surface Forces Logistics Center Standard Specification 3042 (SFLC Std Spec 3042),&nbsp;2022, Shipboard Electrical Cable Removal, Relocation, Splice, Repair, And Installation&nbsp;</p>\n\n<p>Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures</p>\n\n<p><strong>Other References</strong></p>\n\n<p>None.</p>\n\n<p><strong>3. REQUIREMENTS</strong></p>\n\n<p>3.1 <u>General</u>.</p>\n\n<p>3.1.1 <u>CIR</u>.</p>\n\n<p>None.</p>\n\n<p>3.1.2 <u>Technical Representative</u>.&nbsp;</p>\n\n<p>Not applicable.</p>\n\n<p>3.1.3 <u>Protective measures</u>. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).</p>\n\n<p>3.1.4 <u>Interferences</u>. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, (Interferences). Known interferences include, but are not limited to the following:</p>\n\n<ul>\n\t<li>Ventilation screens</li>\n\t<li>Ventilation ducting</li>\n\t<li>Piping</li>\n\t<li>Wiring</li>\n\t<li>Fan mounting and fan supports</li>\n\t<li>Electrical cables</li>\n</ul>\n\n<p>3.1.5 <u>Disposal</u>. The Contractor must dispose of the removed vaneaxial fan and new fan shipping materials in compliance with applicable local, state, and Federal regulations.</p>\n\n<p>3.1.6 <u>Elevated surfaces</u>. The Contractor must, in accordance with CFR Title 29, Part 1915, Subpart E, erect suitable staging or scaffolding, as required, to facilitate work. The Contractor must provide all lifting equipment to remove and re-install the vaneaxial fan assembly in Table 1.</p>\n\n<p>3.1.7 Small boat. Ship&rsquo;s force will remove the small boat located in the Dual Point Davit.</p>\n\n<p><strong>NOTE</strong></p>\n\n<p><strong>Coast Guard personnel will operate all shipboard machinery and equipment.</strong></p>\n\n<p>3.2 <u>Operational test, initial</u>. Prior to commencement of work, the Contractor must witness Coast Guard personnel perform an initial operational test of all items or shipboard devices to be disturbed, used, repaired, or altered, to demonstrate existing operational condition. Submit a CFR</p>\n\n<p>3.3 <u>Temporary ventilation</u>. Not required.</p>\n\n<p>3.4 <u>Vaneaxial fan assembly removal</u>. The Contractor must remove vaneaxial fan assemblies listed in Table 1 from their ventilation ducts. The Contractor must temporarily support the ventilation duct on each side of removed vaneaxial fan assembly.</p>\n\n<p><strong>CAUTION</strong></p>\n\n<p><strong>Multiple sources of power may be present.&nbsp; Ensure that all power sources are secured and tagged prior to the start of any work.&nbsp; All auxiliary circuits in the machine must be de-energized.</strong></p>\n\n<p>3.4.1 Ship Forces will disconnect electric cables to vaneaxial fan assembly in accordance with SFLC Std Spec 3042. Pull back cables and temporarily insulate cable ends for safety. Record wiring information for later re-connection.</p>\n\n<p>3.4.2 The Contractor must clean and inspect three feet of ductwork connected to inlet and outlet of the removed fan. Submit a CFR with inspection results.</p>\n\n<p>3.4.3 The Contractor must test cables between electric motor and control equipment in accordance with SFLC Std Spec 3041. Submit CFR with test results.</p>\n\n<p>3.5 <u>Vaneaxial fan installation</u>. The Contractor must install <u>vaneaxial fan assembly provided as GFM. Follow the installation procedures outlined in CG Tech Pub 7148 Chapter 8. Submit pre-installation testing results via CFR. </u></p>\n\n<p><u>3.5.1 </u>Secure ducting flanges to fan flanges using new stainless steel cap screws, washers, and locknuts.</p>\n\n<p>3.5.2 Restore all ventilation ductwork and ventilation screen to original configuration as shown on Coast Guard Drawing <u>references listed in Section 2</u>. Attach screen using new stainless steel hardware.</p>\n\n<p>3.5.3 Re-connect cables with previously recorded information and firmly secure the cables.&nbsp; Test cables in accordance with SFLC Std Spec 3042 and re-connect the cables with previously recorded wiring information in accordance with SFLC Std Spec 3041.</p>\n\n<p>3.6 <u>Verification</u>.&nbsp; Prior to re-energization, a final closeout inspection must be performed in the presence of the Coast Guard Inspector. Follow the Checkout Procedures outlined in CG Tech Pub 7148. The Contractor must submit a signed completed copy of the inspection checklist via CFR.</p>\n\n<p><strong>CAUTION</strong></p>\n\n<p><strong>To prevent damage to multi-speed motors with possible opposite shaft rotation in different speeds, always start motor directly from off and never shift directly from one speed to another until direction of rotation checks are completed satisfactorily and shaft completely stopped in all speeds.&nbsp; Ensure shaft is not rotating (completely stopped) prior to any restarting of the motor.</strong></p>\n\n<p><strong>NOTE</strong></p>\n\n<p><strong>Coast Guard personnel will operate all shipboard machinery and equipment.</strong></p>\n\n<p>3.7 <u>Operational test, post repairs</u>. After completion of work, the Contractor must thoroughly test, in the presence of the Coast Guard Inspector, and demonstrate all items or shipboard devices that have been disturbed, used, repaired, altered, or installed to be in satisfactory operating condition. Verify that vaneaxial fan assembly is rotating in the proper direction in all speeds. Verify that Vaneaxial Fan Assembly is quiet and vibration free. Operate the fan assembly at its rated speed for 30 minutes. Record current and voltage during the test. Submit a CFR.</p>\n\n<p><strong>4. NOTES</strong></p>\n\n<p>This section is not applicable to this work item.</p>","text":"General Requirements\n\n1. SCOPE\n\n1.1 Intent. This standard specification invokes general requirements for conducting vessel repairs performed by commercial contractors at a Commercial facility for Coast Guard vessels.\n\n2. REFERENCES\n\nCOAST GUARD DRAWINGS\n\nNone.\n\nCOAST GUARD PUBLICATIONS\n\nSurface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements\n\nOTHER REFERENCES\n\nNone.\n\n3. REQUIREMENTS\n\n3.1 General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and in this item, as applicable, during the performance of this availability. The requirements of this WI apply to all work under the scope of this contract, whether explicitly stated in all following work items or not, and to all other work subsequently authorized by changes, modifications, or extensions to the contract.\n\n3.2 Period of Performance. The period of performance for this work is 31JUL26 to 04AUG26.\n\n3.3 Location. The Contractor must perform the work while the USCGC BERTHOLF is alongside the pier at:\n\nSan Diego B Street Pier\n\nSan Diego CA 92132\n\nS26_093_51200_MLA_0726_750\n\n• ITEM 1: Vaneaxial Fan, Renew\n\n1. SCOPE\n\n1.1 Intent. This work item describes the requirements for the Contractor to renew the ventilation fan(s) listed in Table 1.\n\nTABLE 1 – Ventilation Fans for renewal\n\nSYSTEM / FAN NUMBER\n\nmodel number\n\nLOCATION\n\ndimension / APPROX. WEIGHTS\n\ncoast guard DRAWING\n\nSS-64 / 02-48-1\n\nXA20A4W5\n\nFan Space\n\n(02-46-1-Q)\n\n48 in. x 39 in.\n\n1250 lbs.\n\n750-WSML-512-049\n\n1.2 Government-furnished property.\n\nMTI\n\nITEM DESCRIPTION\n\nNSN/PN\n\nQTY\n\nESTIMATED COST\n\n($/UNIT)\n\nN\n\nFan, Vaneaxial\n\n4140-01-603-5356 / XA20A4W5\n\n1 EA\n\n2. REFERENCES\n\nCoast Guard Drawings\n\nCoast Guard Drawing 418A-WMSL-100-001, Rev C, General Arrangements\n\nCoast Guard Drawing 418A-WMSL-512-001, Rev E, HVAC System Diagram\n\nCoast Guard Drawing 418A-WMSL-801-002, Rev (-), Booklet of General Plans\n\nCoast Guard Drawing 750-WMSL-512-049, Rev C, Vent Arr Stack Unit 4320\n\nCoast Guard Drawing 750-WMSL-512-534, Rev D, HVAC Equipment List\n\nCoast Guard Publications\n\nCoast Guard Technical Publication (TP) 7148, SWBS 512, June 2025, Standard XA Vaneaxial Fan\n\nSurface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements\n\nSurface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2022, Welding and Allied Processes\n\nSurface Forces Logistics Center Standard Specification 3020 (SFLC Std Spec 3020), 2022, Overhaul AC Electric Motors\n\nSurface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3041), 2022, Shipboard Electrical Cable Test\n\nSurface Forces Logistics Center Standard Specification 3042 (SFLC Std Spec 3042), 2022, Shipboard Electrical Cable Removal, Relocation, Splice, Repair, And Installation\n\nSurface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2022, Requirements for Preservation of Ship Structures\n\nOther References\n\nNone.\n\n3. REQUIREMENTS\n\n3.1 General.\n\n3.1.1 CIR.\n\nNone.\n\n3.1.2 Technical Representative.\n\nNot applicable.\n\n3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).\n\n3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, (Interferences). Known interferences include, but are not limited to the following:\n\n• Ventilation screens\n\n• Ventilation ducting\n\n• Piping\n\n• Wiring\n\n• Fan mounting and fan supports\n\n• Electrical cables\n\n3.1.5 Disposal. The Contractor must dispose of the removed vaneaxial fan and new fan shipping materials in compliance with applicable local, state, and Federal regulations.\n\n3.1.6 Elevated surfaces. The Contractor must, in accordance with CFR Title 29, Part 1915, Subpart E, erect suitable staging or scaffolding, as required, to facilitate work. The Contractor must provide all lifting equipment to remove and re-install the vaneaxial fan assembly in Table 1.\n\n3.1.7 Small boat. Ship’s force will remove the small boat located in the Dual Point Davit.\n\nNOTE\n\nCoast Guard personnel will operate all shipboard machinery and equipment.\n\n3.2 Operational test, initial. Prior to commencement of work, the Contractor must witness Coast Guard personnel perform an initial operational test of all items or shipboard devices to be disturbed, used, repaired, or altered, to demonstrate existing operational condition. Submit a CFR\n\n3.3 Temporary ventilation. Not required.\n\n3.4 Vaneaxial fan assembly removal. The Contractor must remove vaneaxial fan assemblies listed in Table 1 from their ventilation ducts. The Contractor must temporarily support the ventilation duct on each side of removed vaneaxial fan assembly.\n\nCAUTION\n\nMultiple sources of power may be present. Ensure that all power sources are secured and tagged prior to the start of any work. All auxiliary circuits in the machine must be de-energized.\n\n3.4.1 Ship Forces will disconnect electric cables to vaneaxial fan assembly in accordance with SFLC Std Spec 3042. Pull back cables and temporarily insulate cable ends for safety. Record wiring information for later re-connection.\n\n3.4.2 The Contractor must clean and inspect three feet of ductwork connected to inlet and outlet of the removed fan. Submit a CFR with inspection results.\n\n3.4.3 The Contractor must test cables between electric motor and control equipment in accordance with SFLC Std Spec 3041. Submit CFR with test results.\n\n3.5 Vaneaxial fan installation. The Contractor must install vaneaxial fan assembly provided as GFM. Follow the installation procedures outlined in CG Tech Pub 7148 Chapter 8. Submit pre-installation testing results via CFR.\n\n3.5.1 Secure ducting flanges to fan flanges using new stainless steel cap screws, washers, and locknuts.\n\n3.5.2 Restore all ventilation ductwork and ventilation screen to original configuration as shown on Coast Guard Drawing references listed in Section 2. Attach screen using new stainless steel hardware.\n\n3.5.3 Re-connect cables with previously recorded information and firmly secure the cables. Test cables in accordance with SFLC Std Spec 3042 and re-connect the cables with previously recorded wiring information in accordance with SFLC Std Spec 3041.\n\n3.6 Verification. Prior to re-energization, a final closeout inspection must be performed in the presence of the Coast Guard Inspector. Follow the Checkout Procedures outlined in CG Tech Pub 7148. The Contractor must submit a signed completed copy of the inspection checklist via CFR.\n\nCAUTION\n\nTo prevent damage to multi-speed motors with possible opposite shaft rotation in different speeds, always start motor directly from off and never shift directly from one speed to another until direction of rotation checks are completed satisfactorily and shaft completely stopped in all speeds. Ensure shaft is not rotating (completely stopped) prior to any restarting of the motor.\n\nNOTE\n\nCoast Guard personnel will operate all shipboard machinery and equipment.\n\n3.7 Operational test, post repairs. After completion of work, the Contractor must thoroughly test, in the presence of the Coast Guard Inspector, and demonstrate all items or shipboard devices that have been disturbed, used, repaired, altered, or installed to be in satisfactory operating condition. Verify that vaneaxial fan assembly is rotating in the proper direction in all speeds. Verify that Vaneaxial Fan Assembly is quiet and vibration free. Operate the fan assembly at its rated speed for 30 minutes. Record current and voltage during the test. Submit a CFR.\n\n4. NOTES\n\nThis section is not applicable to this work item.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"70Z08526Q026671","place_of_performance":{"zip":"92132","city":{"code":"66000","name":"San Diego"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J020"},{"dates":{"posted":"2026-07-20","posted_at":"2026-07-20T21:47:24.549Z","created_at":"2026-07-20T21:46:36.202Z","modified_at":"2026-08-08T05:06:44.098Z","response_deadline":{"raw":"2026-07-24T08:00:00-07:00","utc":"2026-07-24T15:00:00Z","date":"2026-07-24","time":"08:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/30c26d1d64774d7797ef552366624193/view"},"naics":{"codes":["33661"],"primary":"33661"},"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","agency":{"office":{"code":"70Z085","name":"SFLC PROCUREMENT BRANCH 2(00085)"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"organization_id":"100187922","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-08","archive_type":"auto15"},"history":[{"index":3,"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-20T21:47:24.549Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"30c26d1d64774d7797ef552366624193","solicitation_number":"70Z08526Q026671","parent_opportunity_id":"e0e4e99377394f37af870966ef71026b"},{"index":1,"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-20T21:44:55.747Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"e0e4e99377394f37af870966ef71026b","solicitation_number":"70Z08526Q026671"}],"contacts":[{"name":"McTague, Sean","role":"primary","email":"Sean.P.McTague@uscg.mil","phone":"15716143888"},{"name":"Lindsay Mongiovi","role":"secondary","email":"lindsay.n.mongiovi@uscg.mil","phone":"5716086752"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"30c26d1d64774d7797ef552366624193","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"e0e4e99377394f37af870966ef71026b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-28T04:34:22.758857415Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"9ee8b4135160a1f8ca59c97c1d97ef80028fae2307d42027c58a56db5048bc7c","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-28T04:34:22.758857415Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Solicitation Number:&nbsp;70Z08526Q026671<br />\nProject Title:&nbsp;CGC Bertholf Oil Purifiers Technical Service.<br />\nResponse Deadline:&nbsp;24JUL 2026</p>\n\n<p><strong>COMBINED SYNOPSIS/SOLICITATION</strong></p>\n\n<p>This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is&nbsp;70Z08526Q026671 and is issued as a request for quotations (RFQ). This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set-aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before&nbsp;24 JUL 2026 and will be reviewed by the Government.</p>\n\n<p>The United States Coast Guard Surface Force Logistics Center has a requirement for the following:<br />\nContractor shall provide parts requested for&nbsp;&nbsp;CGC Bertholf Oil Purifiers Technical Service</p>\n\n<p>TECHNICAL SERVICES FOR INSPECTION AND CORRECTION of the Fuel Oil Purifiers (FOP) onboard USCGC BERTHOLF</p>\n\n<p></p>\n\n<p><strong>Background. </strong>This requirement is for the contractor to Install the parts provided on previous inspection and overhaul both FOP&rsquo;s.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Scope</strong>. The Contractor shall assist cutter personnel with troubleshooting the FOP&rsquo;s :</li>\n</ol>\n\n<ul>\n\t<li>Advise on manufacturer&#39;s proprietary information pertinent to the system.</li>\n\t<li>Assist with proper repair methods and ensure compliance with manufacturer&#39;s procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.</li>\n\t<li>Ensure compliance with manufacturer&#39;s procedures and standards during disassembly, inspection, and reassembly of the FOP.</li>\n</ul>\n\n<p></p>\n\n<ol>\n\t<li><strong>CLIN 0001</strong>: Inspection and Diagnosis (Firm-Fixed-Price)</li>\n</ol>\n\n<p>2.1. Inspection was conducted.</p>\n\n<p>2.2. CFR was submitted by Contractor on previous inspection.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>CLIN 0002</strong>: Repairs.&nbsp;The contractor shall install the parts provided in the attached quote &amp; perform</li>\n</ol>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; a system overhaul.&nbsp;</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Security Requirement</strong>. B Street Pier. Vendor shall have a valid driver&rsquo;s license and show identification. Forms will be provided for base access. A CG representative from the cutter may sponsor and escort vendor to the cutter.</li>\n</ol>\n\n<p></p>\n\n<p><strong>Place of Performance</strong>- CGC BERTHOLF, San Diego CA</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; B Street Pier</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; San Diego CA 92132</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Period of Performance</strong>- 01AUG26 &ndash; 02AUG26 Contractor shall coordinate with POC for 2 days of overhauling &amp; parts replacement withing this POP.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li><strong>Points of Contact</strong>.</li>\n</ol>\n\n<p>USCG-SFLC-LRE PL Asset Management:</p>\n\n<p>MKCM Armando Perez</p>\n\n<p>(757) 560-7289</p>\n\n<p></p>\n\n<p>CGC BERTHOLF Engineer Officer</p>\n\n<p>LCDR Joseph Lacorte</p>\n\n<p>(571) 610-3946</p>","text":"Solicitation Number: 70Z08526Q026671\n\nProject Title: CGC Bertholf Oil Purifiers Technical Service.\n\nResponse Deadline: 24JUL 2026\n\nCOMBINED SYNOPSIS/SOLICITATION\n\nThis is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z08526Q026671 and is issued as a request for quotations (RFQ). This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set-aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 24 JUL 2026 and will be reviewed by the Government.\n\nThe United States Coast Guard Surface Force Logistics Center has a requirement for the following:\n\nContractor shall provide parts requested for CGC Bertholf Oil Purifiers Technical Service\n\nTECHNICAL SERVICES FOR INSPECTION AND CORRECTION of the Fuel Oil Purifiers (FOP) onboard USCGC BERTHOLF\n\nBackground. This requirement is for the contractor to Install the parts provided on previous inspection and overhaul both FOP’s.\n\n• Scope. The Contractor shall assist cutter personnel with troubleshooting the FOP’s :\n\n• Advise on manufacturer's proprietary information pertinent to the system.\n\n• Assist with proper repair methods and ensure compliance with manufacturer's procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.\n\n• Ensure compliance with manufacturer's procedures and standards during disassembly, inspection, and reassembly of the FOP.\n\n• CLIN 0001: Inspection and Diagnosis (Firm-Fixed-Price)\n\n2.1. Inspection was conducted.\n\n2.2. CFR was submitted by Contractor on previous inspection.\n\n• CLIN 0002: Repairs. The contractor shall install the parts provided in the attached quote & perform\n\na system overhaul.\n\n• Security Requirement. B Street Pier. Vendor shall have a valid driver’s license and show identification. Forms will be provided for base access. A CG representative from the cutter may sponsor and escort vendor to the cutter.\n\nPlace of Performance- CGC BERTHOLF, San Diego CA\n\nB Street Pier\n\nSan Diego CA 92132\n\n• Period of Performance- 01AUG26 – 02AUG26 Contractor shall coordinate with POC for 2 days of overhauling & parts replacement withing this POP.\n\n• Points of Contact.\n\nUSCG-SFLC-LRE PL Asset Management:\n\nMKCM Armando Perez\n\n(757) 560-7289\n\nCGC BERTHOLF Engineer Officer\n\nLCDR Joseph Lacorte\n\n(571) 610-3946","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70Z08526Q026671","place_of_performance":{"zip":"92132","city":{"code":"66000","name":"San Diego"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J020"},{"dates":{"posted":"2026-07-20","posted_at":"2026-07-20T21:44:55.747Z","created_at":"2026-07-20T21:26:41.297Z","modified_at":"2026-08-08T05:06:44.098Z","response_deadline":{"raw":"2026-07-24T08:00:00-07:00","utc":"2026-07-24T15:00:00Z","date":"2026-07-24","time":"08:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e0e4e99377394f37af870966ef71026b/view"},"naics":{"codes":["33661"],"primary":"33661"},"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","agency":{"office":{"code":"70Z085","name":"SFLC PROCUREMENT BRANCH 2(00085)"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"organization_id":"100187922","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-08","archive_type":"auto15"},"history":[{"index":3,"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-20T21:47:24.549Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"30c26d1d64774d7797ef552366624193","solicitation_number":"70Z08526Q026671","parent_opportunity_id":"e0e4e99377394f37af870966ef71026b"},{"index":1,"title":"USCGC BERTHOLF OIL PURIFIERS TECHNICAL SERVICE","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-20T21:44:55.747Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"e0e4e99377394f37af870966ef71026b","solicitation_number":"70Z08526Q026671"}],"contacts":[{"name":"ULISES BALMACEDA","role":"primary","email":"Ulises.O.Balmaceda@uscg.mil","phone":"2068200307"},{"name":"Lindsay Mongiovi","role":"secondary","email":"lindsay.n.mongiovi@uscg.mil","phone":"5716086752"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"e0e4e99377394f37af870966ef71026b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"e0e4e99377394f37af870966ef71026b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T00:26:11.153537083Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"3b1b852bac34905b265ac9826cc1a1d15ea6fddc0e05efc5685e53acd9353465","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T00:26:11.153537083Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Solicitation Number:&nbsp;70Z08526Q026671<br />\nProject Title:&nbsp;CGC Bertholf Oil Purifiers Technical Service.<br />\nResponse Deadline:&nbsp;24JUL 2026</p>\n\n<p><strong>COMBINED SYNOPSIS/SOLICITATION</strong></p>\n\n<p>This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is&nbsp;70Z08526Q026671 and is issued as a request for quotations (RFQ). This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set-aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before&nbsp;24 JUL 2026 and will be reviewed by the Government.</p>\n\n<p>The United States Coast Guard Surface Force Logistics Center has a requirement for the following:<br />\nContractor shall provide parts requested for&nbsp;&nbsp;CGC Bertholf Oil Purifiers Technical Service</p>\n\n<p>TECHNICAL SERVICES FOR INSPECTION AND CORRECTION of the Fuel Oil Purifiers (FOP) onboard USCGC BERTHOLF</p>\n\n<p></p>\n\n<p><strong>Background. </strong>This requirement is for the contractor to Install the parts provided on previous inspection and overhaul both FOP&rsquo;s.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Scope</strong>. The Contractor shall assist cutter personnel with troubleshooting the FOP&rsquo;s :</li>\n</ol>\n\n<ul>\n\t<li>Advise on manufacturer&#39;s proprietary information pertinent to the system.</li>\n\t<li>Assist with proper repair methods and ensure compliance with manufacturer&#39;s procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.</li>\n\t<li>Ensure compliance with manufacturer&#39;s procedures and standards during disassembly, inspection, and reassembly of the FOP.</li>\n</ul>\n\n<p></p>\n\n<ol>\n\t<li><strong>CLIN 0001</strong>: Inspection and Diagnosis (Firm-Fixed-Price)</li>\n</ol>\n\n<p>2.1. Inspection was conducted.</p>\n\n<p>2.2. CFR was submitted by Contractor on previous inspection.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>CLIN 0002</strong>: Repairs.&nbsp;The contractor shall install the parts provided in the attached quote &amp; perform</li>\n</ol>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; a system overhaul.&nbsp;</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Security Requirement</strong>. B Street Pier. Vendor shall have a valid driver&rsquo;s license and show identification. Forms will be provided for base access. A CG representative from the cutter may sponsor and escort vendor to the cutter.</li>\n</ol>\n\n<p></p>\n\n<p><strong>Place of Performance</strong>- CGC BERTHOLF, San Diego CA</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; B Street Pier</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; San Diego CA 92132</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Period of Performance</strong>- 01AUG26 &ndash; 02AUG26 Contractor shall coordinate with POC for 2 days of overhauling &amp; parts replacement withing this POP.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li><strong>Points of Contact</strong>.</li>\n</ol>\n\n<p>USCG-SFLC-LRE PL Asset Management:</p>\n\n<p>MKCM Armando Perez</p>\n\n<p>(757) 560-7289</p>\n\n<p></p>\n\n<p>CGC BERTHOLF Engineer Officer</p>\n\n<p>LCDR Joseph Lacorte</p>\n\n<p>(571) 610-3946</p>","text":"Solicitation Number: 70Z08526Q026671\n\nProject Title: CGC Bertholf Oil Purifiers Technical Service.\n\nResponse Deadline: 24JUL 2026\n\nCOMBINED SYNOPSIS/SOLICITATION\n\nThis is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z08526Q026671 and is issued as a request for quotations (RFQ). This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set-aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 24 JUL 2026 and will be reviewed by the Government.\n\nThe United States Coast Guard Surface Force Logistics Center has a requirement for the following:\n\nContractor shall provide parts requested for CGC Bertholf Oil Purifiers Technical Service\n\nTECHNICAL SERVICES FOR INSPECTION AND CORRECTION of the Fuel Oil Purifiers (FOP) onboard USCGC BERTHOLF\n\nBackground. This requirement is for the contractor to Install the parts provided on previous inspection and overhaul both FOP’s.\n\n• Scope. The Contractor shall assist cutter personnel with troubleshooting the FOP’s :\n\n• Advise on manufacturer's proprietary information pertinent to the system.\n\n• Assist with proper repair methods and ensure compliance with manufacturer's procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.\n\n• Ensure compliance with manufacturer's procedures and standards during disassembly, inspection, and reassembly of the FOP.\n\n• CLIN 0001: Inspection and Diagnosis (Firm-Fixed-Price)\n\n2.1. Inspection was conducted.\n\n2.2. CFR was submitted by Contractor on previous inspection.\n\n• CLIN 0002: Repairs. The contractor shall install the parts provided in the attached quote & perform\n\na system overhaul.\n\n• Security Requirement. B Street Pier. Vendor shall have a valid driver’s license and show identification. Forms will be provided for base access. A CG representative from the cutter may sponsor and escort vendor to the cutter.\n\nPlace of Performance- CGC BERTHOLF, San Diego CA\n\nB Street Pier\n\nSan Diego CA 92132\n\n• Period of Performance- 01AUG26 – 02AUG26 Contractor shall coordinate with POC for 2 days of overhauling & parts replacement withing this POP.\n\n• Points of Contact.\n\nUSCG-SFLC-LRE PL Asset Management:\n\nMKCM Armando Perez\n\n(757) 560-7289\n\nCGC BERTHOLF Engineer Officer\n\nLCDR Joseph Lacorte\n\n(571) 610-3946","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"70Z08526Q026671","place_of_performance":{"zip":"92132","city":{"code":"66000","name":"San Diego"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J020"}],"due_at":"2026-07-24T15:00:00Z","due_date":"2026-07-24","closes_at":"2026-07-24T15:00:00Z","awardable":true,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-29T01:07:38.873437Z","principal_notice_id":"e0e4e99377394f37af870966ef71026b","description":{"text":"Solicitation Number: 70Z08526Q026671\n\nProject Title: CGC Bertholf Oil Purifiers Technical Service.\n\nResponse Deadline: 24JUL 2026\n\nCOMBINED SYNOPSIS/SOLICITATION\n\nThis is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z08526Q026671 and is issued as a request for quotations (RFQ). This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set-aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 24 JUL 2026 and will be reviewed by the Government.\n\nThe United States Coast Guard Surface Force Logistics Center has a requirement for the following:\n\nContractor shall provide parts requested for CGC Bertholf Oil Purifiers Technical Service\n\nTECHNICAL SERVICES FOR INSPECTION AND CORRECTION of the Fuel Oil Purifiers (FOP) onboard USCGC BERTHOLF\n\nBackground. This requirement is for the contractor to Install the parts provided on previous inspection and overhaul both FOP’s.\n\n• Scope. The Contractor shall assist cutter personnel with troubleshooting the FOP’s :\n\n• Advise on manufacturer's proprietary information pertinent to the system.\n\n• Assist with proper repair methods and ensure compliance with manufacturer's procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.\n\n• Ensure compliance with manufacturer's procedures and standards during disassembly, inspection, and reassembly of the FOP.\n\n• CLIN 0001: Inspection and Diagnosis (Firm-Fixed-Price)\n\n2.1. Inspection was conducted.\n\n2.2. CFR was submitted by Contractor on previous inspection.\n\n• CLIN 0002: Repairs. The contractor shall install the parts provided in the attached quote & perform\n\na system overhaul.\n\n• Security Requirement. B Street Pier. Vendor shall have a valid driver’s license and show identification. Forms will be provided for base access. A CG representative from the cutter may sponsor and escort vendor to the cutter.\n\nPlace of Performance- CGC BERTHOLF, San Diego CA\n\nB Street Pier\n\nSan Diego CA 92132\n\n• Period of Performance- 01AUG26 – 02AUG26 Contractor shall coordinate with POC for 2 days of overhauling & parts replacement withing this POP.\n\n• Points of Contact.\n\nUSCG-SFLC-LRE PL Asset Management:\n\nMKCM Armando Perez\n\n(757) 560-7289\n\nCGC BERTHOLF Engineer Officer\n\nLCDR Joseph Lacorte\n\n(571) 610-3946","html":"<p>Solicitation Number:&nbsp;70Z08526Q026671<br />\nProject Title:&nbsp;CGC Bertholf Oil Purifiers Technical Service.<br />\nResponse Deadline:&nbsp;24JUL 2026</p>\n\n<p><strong>COMBINED SYNOPSIS/SOLICITATION</strong></p>\n\n<p>This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is&nbsp;70Z08526Q026671 and is issued as a request for quotations (RFQ). This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set-aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before&nbsp;24 JUL 2026 and will be reviewed by the Government.</p>\n\n<p>The United States Coast Guard Surface Force Logistics Center has a requirement for the following:<br />\nContractor shall provide parts requested for&nbsp;&nbsp;CGC Bertholf Oil Purifiers Technical Service</p>\n\n<p>TECHNICAL SERVICES FOR INSPECTION AND CORRECTION of the Fuel Oil Purifiers (FOP) onboard USCGC BERTHOLF</p>\n\n<p></p>\n\n<p><strong>Background. </strong>This requirement is for the contractor to Install the parts provided on previous inspection and overhaul both FOP&rsquo;s.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Scope</strong>. The Contractor shall assist cutter personnel with troubleshooting the FOP&rsquo;s :</li>\n</ol>\n\n<ul>\n\t<li>Advise on manufacturer&#39;s proprietary information pertinent to the system.</li>\n\t<li>Assist with proper repair methods and ensure compliance with manufacturer&#39;s procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.</li>\n\t<li>Ensure compliance with manufacturer&#39;s procedures and standards during disassembly, inspection, and reassembly of the FOP.</li>\n</ul>\n\n<p></p>\n\n<ol>\n\t<li><strong>CLIN 0001</strong>: Inspection and Diagnosis (Firm-Fixed-Price)</li>\n</ol>\n\n<p>2.1. Inspection was conducted.</p>\n\n<p>2.2. CFR was submitted by Contractor on previous inspection.</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>CLIN 0002</strong>: Repairs.&nbsp;The contractor shall install the parts provided in the attached quote &amp; perform</li>\n</ol>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; a system overhaul.&nbsp;</p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Security Requirement</strong>. B Street Pier. Vendor shall have a valid driver&rsquo;s license and show identification. Forms will be provided for base access. A CG representative from the cutter may sponsor and escort vendor to the cutter.</li>\n</ol>\n\n<p></p>\n\n<p><strong>Place of Performance</strong>- CGC BERTHOLF, San Diego CA</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; B Street Pier</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; San Diego CA 92132</p>\n\n<p></p>\n\n<p></p>\n\n<ol>\n\t<li><strong>Period of Performance</strong>- 01AUG26 &ndash; 02AUG26 Contractor shall coordinate with POC for 2 days of overhauling &amp; parts replacement withing this POP.</li>\n</ol>\n\n<p></p>\n\n<ol>\n\t<li><strong>Points of Contact</strong>.</li>\n</ol>\n\n<p>USCG-SFLC-LRE PL Asset Management:</p>\n\n<p>MKCM Armando Perez</p>\n\n<p>(757) 560-7289</p>\n\n<p></p>\n\n<p>CGC BERTHOLF Engineer Officer</p>\n\n<p>LCDR Joseph Lacorte</p>\n\n<p>(571) 610-3946</p>","origin":"detail"},"contacts":[{"name":"ULISES BALMACEDA","role":"primary","email":"Ulises.O.Balmaceda@uscg.mil","phone":"2068200307"},{"name":"Lindsay Mongiovi","role":"secondary","email":"lindsay.n.mongiovi@uscg.mil","phone":"5716086752"}],"place_of_performance":{"zip":"92132","city":{"code":"66000","name":"San Diego"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"94501","city":"ALAMEDA","state":"CA","country":"USA"},"naics_codes":["33661"],"award":null,"attachments":[{"resource_id":"b9b29bda1fc04da39ba3d0ee54abff6f","name":"26091 - SOW - Bertholf FOP.docx","kind":"file","mime_type":".docx","size_bytes":27567,"posted_at":"2026-07-20T21:44:55.747Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b9b29bda1fc04da39ba3d0ee54abff6f/download","mirrored":false},{"resource_id":"4e1d7e877e094ee49e87c0c10e642905","name":"SOW_Bertholf Solicitation.docx","kind":"file","mime_type":".docx","size_bytes":48435,"posted_at":"2026-07-15T19:21:16.830Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4e1d7e877e094ee49e87c0c10e642905/download","mirrored":false}],"awards":[],"related":[{"key":"70Z08526RRJ001B00","latest_notice_id":"79adb3e9f10f4bceafdeca530cb99fdf","title":"TRS-3D /AN/SPS-75 Radar repairs/ overhaul services","solicitation_number":"70Z08526RRJ001B00","notice_type":"o","first_type":"o","first_posted":"2026-07-15","last_posted":"2026-11-19","notices":8,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"811210","psc":"J059","set_aside":null,"state":"MD","county":"24510","county_name":"City of Baltimore","city":"2404000","city_name":"Baltimore","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"70Z08526Q39002B00","latest_notice_id":"c2c828ffaf9848a1a975736420ad55cf","title":"ACTUATOR,GOVERNOR","solicitation_number":"70Z08526Q39002B00","notice_type":"o","first_type":"o","first_posted":"2025-12-10","last_posted":"2025-12-10","notices":1,"due_at":"2026-12-19T16:00:00Z","due_date":"2026-12-19","closes_at":"2026-12-19T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z085","office_name":"SFLC PROCUREMENT BRANCH 2(00085)","naics":"336611","psc":"2990","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 2990)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open":[{"key":"N6117727R5000","latest_notice_id":"4e39cdb3eaed481ca0ce10d27f0fd6f0","title":"Southwest Regional Maintenance Center (SWRMC) Indefinite Delivery Indefinite Quantity-Multiple Award Contract (IDIQ-MAC) for Non-Nuclear Surface Ship Maintenance, Repair and Modernization","solicitation_number":"N6117727R5000","notice_type":"o","first_type":"p","first_posted":"2026-10-15","last_posted":"2026-11-19","notices":3,"due_at":"2027-01-20T19:00:00Z","due_date":"2027-01-20","closes_at":"2027-01-20T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N61177","office_name":"PAE MARITIME","naics":"33661","psc":"J999","set_aside":"SBP","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"11242026","latest_notice_id":"ed4a149d4abf4297a96eb802ef3f7895","title":"MARAD Small Business, Shipyard & VCM Market Research Agenda","solicitation_number":"11242026","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-14T18:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-069","dept_name":"TRANSPORTATION, DEPARTMENT OF","sub_key":"s-6938","sub_name":"MARITIME ADMINISTRATION","office_key":"o-693JF7","office_name":"693JF7 DOT MARITIME ADMINISTRATION","naics":"33661","psc":"1910","set_aside":"SBA","state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":2,"indexable":false}