Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,696 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans

Combined synopsis and solicitation, total small business set-aside

USCGC Alex Haley MRG Coolers Repair

70Z08526Q0023411

US Coast Guard, SFLC Procurement Branch 2. Ship Building and Repairing.

Response deadline

March 12, 2026 at 11:00 AM EDT

Closed 259 days ago. Posted March 8, 2026. Scheduled to archive March 27, 2026.

Get the next one like this from US Coast Guard by email, the day it is posted.Find my opportunities

This one closed in 2026

107 like it are open now in ship building and repairing

  • USNS CITY OF BISMARCK (T-EPF 9) VRA KR

    Department of the Navy, NAVSUP FLT Log CTR Yokosuka

    SolicitationNAICS 336611Outside the USN6264927RK003
    Due tomorrowNov 27
  • Ship Repair

    Department of the Navy, NAVSUP FLC Sigonella Naples Office

    SolicitationNAICS 336611Outside the USN6817127QN013
    Due tomorrowNov 27
  • WATCH SUPV CHAIR

    Department of the Navy, NAVSUP Weapon Systems Support Mech

    SolicitationNAICS 336611Ship to the buyerN0010427QBB55
    Due tomorrowNov 27

All 107 open in ship building and repairing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
Who may compete
Total small business set-aside. Only small businesses may compete. Small, under NAICS 336611 (ship building and repairing), means no more than 1,300 employees, counted with affiliates. Open Small business opportunities
Time to respond
Bidders had 4 days from the day the solicitation was posted, March 8, 2026, to the deadline.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

TECHNICAL SERVICES

USCGC ALEX HALEY (WMEC-39) – Z12204

REPAIRS TO REDUCTION GEAR COOLERS

  1. Objective. The objective of this requirement is to conduct repairs to the salt water and lube oil shell and tube cooler(s) for a shipboard propulsion reduction gear on CGC Alex Haley.

  1. References. For any listed references to be distributed, the contractor must be registered in the Joint Certification Program (JCP) through Defense Logistics Agency (DLA) and provide your JCP number to the listed point of contact for this work.
    1. COMDTINST 9077.1 (series), Equipment Tag Out Procedures
    2. Technical Publication 0942-LP-013-2010-241-A, Reduction Gear & Associated Equipment - ATS-1-Salvage Tugs
    3. Naval Ships Technical Manual (NSTM) S9086-HY-STM-010, Chapter 254, Condensers, Heat Exchangers and Air Ejectors. (28 March 2024).
    4. NAVSEA S9531-BH-MMI-010, Technical Manual for Heat Exchanger Repair of Heat Exchangers, Coolers, and Distilling Plants, Rev 3.
    5. COMDTINST M10360.3 (series), Coatings and Color Manual
    6. SFLC Standard Specification 6310, Requirements for Preservation of Ship Structures
  2. Background. During an inspection, the ship’s technicians identified multiple tubes leaking and plugged for both port and starboard reduction gear heat exchangers. This requirement is for the contractor to inspect, test, and repair the port and starboard coolers for further operations. Per reference in section 2, only 10% of tubes are allowed to be plugged for efficient heat transfer and reduction gears to operation as designed.

  1. Tasks. The contractor shall provide material and labor services, of which includes but may not limited to:
    1. The contractor must receive the cooler(s) from the USCG and provide a Material Receiving Report to the listed technical points of contact (TPOCs) within 24 hours of receipt.
    2. The contractor must chemically clean and inspect the cooler(s) in accordance with (IAW) references in section 2. Provide a written Condition Found Report (CFR) for the coolers to the listed TPOCs and the Contracting Officer within 24 hours of the completion of the inspection.
      1. The Contractor is responsible for all safety precautions and for the disposal of all cleaning solutions and chemicals IAW local, state, and federal hazardous waste regulations. Under no circumstances are cleaning solutions, chemicals or rinsing and flushing water to be discharged to the vessel’s bilges. In that eventuality, the Contractor is responsible for their removal and disposal and the restoration of the effected compartments to the satisfaction of the TPOCs.
    3. The contractor must perform a hydrostatic test on the cooler, using clean potable water (no substitutes are allowed) IAW references in section 2. The Contractor must provide a CFR with results and repair plan to the listed TPOCs and the Contracting Officer within 24 hours of the test. If discrepancies are found, provide a detailed repair plan with associated costs to the listed TPOCs within 24 hours of the test. The CFR shall be limited to technical findings and recommended repairs; it shall not include pricing or cost information.
    4. For proposal purposes, the base requirement shall include replacement of up to six (6) tubes per cooler. The contractor shall provide technical findings and the number of additional tubes recommended for replacement (if any) to the TPOCs and the Contracting Officer. Pricing for any additional tube replacements beyond six (6) per cooler will be requested and handled by the Contracting Officer under the terms of the contract any repairs beyond the base scope identified as a result of the inspection and testing shall be documented in a Condition Found Report (CFR) with a technical description of the recommended repairs. The CFR shall be provided to the TPOCs and the Contracting Officer. Any additional work will be authorized only by the Contracting Officer through a written contract modification. The contractor shall not perform any repairs beyond the base scope until specifically authorized in writing by the Contracting Officer. If the Government elects to proceed with additional repairs, the Contracting Officer will issue a written contract modification that identifies the authorized additional work and associated firm fixed price. The contractor shall base any proposal for additional repairs on the findings in the CFR. Repeat hydrostatic testing and demonstrate no leaking tubes to the TPOCs. Submit a CFR detailing satisfactory hydrostatic test and note the parameters of throughout the test. Affix a metal tag or brass plate using lock wire to the cooler noting ship name and hull number, hydrostatic test pressure, date tested, name and location of repair facility (contractor).
    5. After any repairs, the contractor shall re-assembly the cooler with newly furnished gaskets and/or rings. Ensure all internal surfaces are clean. Perform touch-up surface preservation IAW references in section 2.
    6. The Contractor shall delivery the repaired cooler in suitable crates or boxes to protect the component during rigging and transporting. The Contractor is responsible for freight costs to return address.

  1. Government Furnished Property.
    1. Government‑Furnished Property.
      The Government will furnish the following coolers to the contractor for inspection, testing, and repair under this requirement:

Reduction gear cooler #1, Serial Number TL 7616, NSN 4420‑01‑275‑9019, P/N 44254‑1021, Serck Radiators LTD, MFR DWG 1009677, 36 tubes, tube size 0.625 OD x 0.049 x 45.375 inches. Reduction gear cooler #2, Serial Number TL 7617, same configuration as above.

  1. Security Requirement. Base access is not required. If access needed, Contractor shall have a valid government issued ID (or driver’s license) and show identification at the security gate. Contractor must provide full name, date of birth, and driver’s license #. Only REAL ID Act compliant driver’s licenses and ID cards are authorized for base access. Upon request, USCG members can escort Contractor on and off the facility.

  1. Place of Performance. Contractor’s designated repair facility. Delivery to USCGC Alex Haley (WMEC-39), 26 Albatross Ave, Kodiak, AK 99619, United States

  1. Period of Performance. 9-March to 17-April 2026

  1. Technical Points of Contact.
    1. USCG-SFLC-LREPL Asset Management: LT Mikael Axelsson, Mikael.J.Axelsson@uscg.mil, 571-607-1134
    2. USCGC ALEX HALEY, Engineer Officer: LT Alex Murdoch, Alexander.S.Murdoch@uscg.mil

  1. Notes.
    1. Cooler Fluid, NSN: 4420-01-275-9019, P/N: 44254-1021, Serck Radiators LTD, MFR DWG 1009677, number of tubes: 36, tube sizing: 0.625 OD x 0.049 x 45.375 [inches]
    2. Data Plate Information
      1. Serial Number: 1 Cooler: TL 7616, and #2 Cooler: TL 7617
      2. Test Pressures: L/O Test PSI (shell): 150 PSI, R/W Test PSI (tubes): 100 PSI

  1. Photos.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. March 9, 2026

    Combined synopsis and solicitation

    Due March 12, 2026 at 11:00 AM EDT. SAM.gov, notice 2905fe9bace04c35a73df9d5fae443f3

    1 revision on SAM
    • March 9, 2026: publish, combined synopsis and solicitation

Points of contact