Combined synopsis and solicitation, total small business set-aside
CGC STURGEON BAY WATER MIST FIRE SUPRESSION TESTING WITH UPDATE SOW
70Z08526Q0000855
US Coast Guard, SFLC Procurement Branch 2. Ship Building and Repairing.
Response deadline
December 19, 2025 at 11:00 AM EST
Closed 341 days ago. Posted December 11, 2025, first published November 21, 2025. Scheduled to archive January 3, 2026.
Get the next one like this from US Coast Guard by email, the day it is posted.Find my opportunities
This one closed in 2025
103 like it are open now in ship building and repairing
- USNS CITY OF BISMARCK (T-EPF 9) VRA KR
Department of the Navy, NAVSUP FLT Log CTR Yokosuka
SolicitationNAICS 336611Outside the USN6264927RK003Due in 2 daysNov 27 - Ship Repair
Department of the Navy, NAVSUP FLC Sigonella Naples Office
SolicitationNAICS 336611Outside the USN6817127QN013Due in 2 daysNov 27 - WATCH SUPV CHAIR
Department of the Navy, NAVSUP Weapon Systems Support Mech
SolicitationNAICS 336611Ship to the buyerN0010427QBB55Due in 2 daysNov 27
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Combined synopsis and solicitation. A streamlined commercial-item buy where the notice itself is the solicitation. Glossary
- Who may compete
- Total small business set-aside. Only small businesses may compete. Small, under NAICS 336611 (ship building and repairing), means no more than 1,300 employees, counted with affiliates. Open Small business opportunities
- Time to respond
- Bidders had 28 days from the day the solicitation was posted, November 21, 2025, to the deadline. The deadline moved once: it was first November 28, 2025 and ended as December 19, 2025.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
This is a combined synopsis/solicitation
This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z08526Q0000855 and is issued as a request for quotations (RFQ). This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 0800 Pacific Time, December 29th, 2025, and will be reviewed by the Government.
The United States Coast Guard Surface Force Logistics Center has a requirement for the following:
Contractor shall provide parts requested for USCGC STURGEON BAY Fire Suppression System Testing:
STATEMENT OF WORK
CGC STURGEON BAY OPFAC: 17509 LOCATION: Bayonne, NJ
EQUIPMENT: Hi-Fog Water Mist Fire Suppression System
COMPONENT AFFECTED: 5yr and ANNUAL INSPECTION OF SYSTEM/ Renewal of 29 Bottles and certified
MPC: R-A-13380, R-M-13373, R-C-14526
Contractor must be HI-FOG certified Technician. Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractor must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractor shall use MPC R-A-13380, R-M-13373, R-C-14526 as guidance.
Replacement Parts to be included in 5-Year Annual Inspection
1 - PNEUMATIC REPAIR KIT WITH SILENCER (G40090) 1 - HYDRAULICREPAIR KIT (G40095) 30 - HOSE 36INCH 8MM FOR GPU (UU1168) 1 - HOSE ASSEMBLY - N2 REGULATOR (A20079.1) 2 - FILTER WATERFILTER R1 1/2, 60-MICROMETER (E31048) 1 - LOW PRESSURE FRESH WATER SAFETY VALVES (M-0010165) 2 - SVM20 DNV VALVEREBUILD KITS (V14020)
Any discrepancies found shall be noted; and corrected only if no other cost is needed. If any discrepancy causes cost outside the quote, this shall be routed through customer before discrepancy is corrected.
POP: 22DEC2025-29DEC2025
LOCATION/POC:
MCKM Thaddeus Brandt
Engineer Petty Officer
USCGSC Sturgeon Bay
85 PORT TERMINAL BLVD, SLIP 3
BAYONNE, NJ 07002
US
(201) 912-7910 (work)
(631) 655-4034 (personal)
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 25033-Sturgeon Bay-SOW FOR ANNUAL WATER MIST INSPECTION.docx15 KB, November 22, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
November 22, 2025
Combined synopsis and solicitation
CGC STURGEON BAY WATER MIST FIRE SUPRESSION TESTING
Due November 28, 2025 at 11:00 AM EST. SAM.gov, notice 3da038ffa16148bb88ee551a92c797f4
2 revisions on SAM
- December 11, 2025: publish, combined synopsis and solicitation
- November 22, 2025: publish, combined synopsis and solicitation
December 11, 2025
Combined synopsis and solicitation
Due December 19, 2025 at 11:00 AM EST. SAM.gov, notice ce79bcc49c724f28b10c693db288c56a
2 revisions on SAM
- December 11, 2025: publish, combined synopsis and solicitation
- November 22, 2025: publish, combined synopsis and solicitation
Points of contact
- DONNA O'NEALDonna.J.O'Neal@uscg.mil5103931145
- ULISES BALMACEDAUlises.O.Balmaceda@uscg.mil2068200307