{"canonical":"https://sealedbidder.com/opportunities/36c26326q0227","key":"36C26326Q0227","url":"https://sealedbidder.com/opportunities/36c26326q0227","title":"6640--EQ Stereotaxic Instrument in support of the Sioux Falls VAHC System","solicitation_number":"36C26326Q0227","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-01-06T16:00:00Z","first_posted":"2025-12-18","last_posted":"2025-12-18","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"339112","psc":"6640","set_aside":null,"place_state":"SD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"46099","place_county_name":"Minnehaha County","place_city":"4659020","place_city_name":"Sioux Falls","winner":null,"award_amount":null,"publications":[{"notice_id":"bdffc965404348bbbc9be1d39253efea","title":"6640--EQ Stereotaxic Instrument in support of the Sioux Falls VAHC System","solicitation_number":"36C26326Q0227","notice_type":"r","base_type":"r","posted":"2025-12-18","posted_at":"2025-12-18T19:18:43.204Z","due_at":"2026-01-06T16:00:00Z","due_date":"2026-01-06","cancelled":false,"archived":true,"archive_date":"2026-03-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/bdffc965404348bbbc9be1d39253efea/view","enriched":true,"history":[{"index":3,"title":"6640--EQ Stereotaxic Instrument in support of the Sioux Falls VAHC System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-18T19:18:43.204Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"bdffc965404348bbbc9be1d39253efea","solicitation_number":"36C26326Q0227"}]}],"latest_notice_id":"bdffc965404348bbbc9be1d39253efea","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-12-18","posted_at":"2025-12-18T19:18:43.204Z","created_at":"2025-12-18T19:18:40.562Z","modified_at":"2026-03-08T04:55:43.778Z","response_deadline":{"raw":"2026-01-06T10:00:00-06:00","utc":"2026-01-06T16:00:00Z","date":"2026-01-06","time":"10:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/bdffc965404348bbbc9be1d39253efea/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6640--EQ Stereotaxic Instrument in support of the Sioux Falls VAHC System","agency":{"office":{"code":"36C263","name":"NETWORK CONTRACT OFFICE 23 (36C263)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"55101","city":"Saint Paul","state":"MN","country":"USA"},"organization_id":"100183219","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-07","archive_type":"auto_custom"},"history":[{"index":3,"title":"6640--EQ Stereotaxic Instrument in support of the Sioux Falls VAHC System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-18T19:18:43.204Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"bdffc965404348bbbc9be1d39253efea","solicitation_number":"36C26326Q0227"}],"contacts":[{"name":"Marie Weathers","role":"primary","email":"marie.weathers@va.gov","phone":"605-347-2511","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"bdffc965404348bbbc9be1d39253efea","lineage_id":"bdffc965404348bbbc9be1d39253efea","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-18T04:13:24.114003749Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"c85b5c64106acfa622b89af3078b0ec43769899e95c1e5a8df61fe1f0ef8f027","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-18T04:13:24.114003749Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"REQUEST FOR INFORMATION / SOURCES SOUGHT for Stereotaxic Instrument, Brand-Name Only\n\nDEPARTMENT OF VETERANS AFFAIRS, VISN 23 Source Sought:  The VA is seeking business sources qualified to provide the items listed below as Brand Name or Equal.  This is NOT a solicitation. \n\nINTERESTED SOURCES SHALL RESPOND BY:\n\nPlease submit response no later than 10:00am CST Tuesday, January 06, 2026\n\nAll responses and questions must be emailed to marie.weathers@va.gov and must include in the subject line:  Sources Sought Stereotaxic Instrument 36C26326Q0227\n\nPOTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:\n\n1. Company name, address, phone number, primary contact(s), e-mail address.\n\n2. State if your firm distributes the Brand Name items, or Equal items. \n\n3. SAM UEI number.\n\n4. NAICS (North American Industry Classification System) code 339112 that your firm uses for injection pumps and modules.\n\n5. State if your firm is a large business, small business, service-disabled-veteran-owned \nsmall business, veteran-owned small business, HUB zone 8(a), women-owned small business or a small disadvantaged business.\n\n 6. State if your firm has the required items on Schedule (FSS, GSA, SEWP, other ).\n\n7. Provide a letter from the manufacturer verifying your firm is an authorized distributor.\n\n 8. Provide the country of origin for each of the required items.\n \nREQUIRED ITEM and Salient Characteristics:\nContractor shall provide brand-name only Kopf Instruments: \n Model 942 Small Animal Stereotaxic Instrument with Digital Display Console\n  Must allow for X, Y, Z adjustments to include 10-micron resolution and include a compact digital display console. The digital display control must allow the user to  zero  reset at any position. Metric scale 80 mm calibrated 0.1 mm vernier scale.\n  Must ensure that angle adjustment is available through a universal joint calibrated on two planes for access from any angle. Must have the ability to remove the vertical alignment pin to allow angled settings from 0Â°   90Â° either side of vertical, 2Â° increments.\n  Must provide rotation adjustment through a manipulator swivel base that can be rotated up to 360Â°. Manipulator X/Z axis must be able to reposition at 90Â° increments. \n  The stereotaxic frame must be mounted to a 13.9 L x 10 W base plate and elevated to bring ear bar height to 53 mm. \n  Ear bar slots on the  U  frame must have 0.1 mm verniers for centering the animal. Ear bar zero to posterior end of base plate is 8.763 .\n\nB. Model 923-B Mouse Gas Anesthesia Head Holder\n  Gas Anesthesia Mask must have an inlet/outlet ports (1/8  dia.)\n  Must be compatible with Ear Bar Model 1922 Non-Rupture 60Â° Tip Mouse Ear Bars.\n\nC. Model 921 Zygoma Ear Cups\n  Must allow for a 25Â° with 5Â° graduations in tilt for Dorsal/Ventral tilt\n  Must provide a 35Â° (5Â° graduations) coronal adjustment\n  Must provide a 44mm Adaptor Plate A/P adjustment\n\nD. Model 1474 Stereotaxic Drill includes tabletop\n*** Includes tabletop motor controller, foot pedal, and piece holder.\n  Must include tabletop motor controller, foot pedal and piece holder\n  Drill size must be 6  in overall length\n  Must have a 5/8  grip diameter\n  Must have a 1  motor diameter\n\nE. Model 1772 Universal Holder\n\nF. Model 1771-A-Mod Electrode Holder with Straight Clamp\n\nG. Model 905 Head Alignment Tool (leveling device)\n\nH. Estimated UPS 3 Day freight charges\n\nDISCLAIMER AND ADDITIONAL NOTICES:\n\nResponses may be used as research to better understand the marketplace or for creating a potential future acquisition.  Response is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this or future information requests.\n\nAT THIS TIME NO SOLICITATION EXISTS.  (DO NOT REQUEST A COPY OF THE SOLICITATION).\n\nThis notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.\n\nNo Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s.)","text":"REQUEST FOR INFORMATION / SOURCES SOUGHT for Stereotaxic Instrument, Brand-Name Only\n\nDEPARTMENT OF VETERANS AFFAIRS, VISN 23 Source Sought: The VA is seeking business sources qualified to provide the items listed below as Brand Name or Equal. This is NOT a solicitation.\n\nINTERESTED SOURCES SHALL RESPOND BY:\n\nPlease submit response no later than 10:00am CST Tuesday, January 06, 2026\n\nAll responses and questions must be emailed to marie.weathers@va.gov and must include in the subject line: Sources Sought Stereotaxic Instrument 36C26326Q0227\n\nPOTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:\n\n1. Company name, address, phone number, primary contact(s), e-mail address.\n\n2. State if your firm distributes the Brand Name items, or Equal items.\n\n3. SAM UEI number.\n\n4. NAICS (North American Industry Classification System) code 339112 that your firm uses for injection pumps and modules.\n\n5. State if your firm is a large business, small business, service-disabled-veteran-owned\nsmall business, veteran-owned small business, HUB zone 8(a), women-owned small business or a small disadvantaged business.\n\n6. State if your firm has the required items on Schedule (FSS, GSA, SEWP, other ).\n\n7. Provide a letter from the manufacturer verifying your firm is an authorized distributor.\n\n8. Provide the country of origin for each of the required items.\n\nREQUIRED ITEM and Salient Characteristics:\nContractor shall provide brand-name only Kopf Instruments:\nModel 942 Small Animal Stereotaxic Instrument with Digital Display Console\nMust allow for X, Y, Z adjustments to include 10-micron resolution and include a compact digital display console. The digital display control must allow the user to zero reset at any position. Metric scale 80 mm calibrated 0.1 mm vernier scale.\nMust ensure that angle adjustment is available through a universal joint calibrated on two planes for access from any angle. Must have the ability to remove the vertical alignment pin to allow angled settings from 0Â° 90Â° either side of vertical, 2Â° increments.\nMust provide rotation adjustment through a manipulator swivel base that can be rotated up to 360Â°. Manipulator X/Z axis must be able to reposition at 90Â° increments.\nThe stereotaxic frame must be mounted to a 13.9 L x 10 W base plate and elevated to bring ear bar height to 53 mm.\nEar bar slots on the U frame must have 0.1 mm verniers for centering the animal. Ear bar zero to posterior end of base plate is 8.763 .\n\nB. Model 923-B Mouse Gas Anesthesia Head Holder\nGas Anesthesia Mask must have an inlet/outlet ports (1/8 dia.)\nMust be compatible with Ear Bar Model 1922 Non-Rupture 60Â° Tip Mouse Ear Bars.\n\nC. Model 921 Zygoma Ear Cups\nMust allow for a 25Â° with 5Â° graduations in tilt for Dorsal/Ventral tilt\nMust provide a 35Â° (5Â° graduations) coronal adjustment\nMust provide a 44mm Adaptor Plate A/P adjustment\n\nD. Model 1474 Stereotaxic Drill includes tabletop\n*** Includes tabletop motor controller, foot pedal, and piece holder.\nMust include tabletop motor controller, foot pedal and piece holder\nDrill size must be 6 in overall length\nMust have a 5/8 grip diameter\nMust have a 1 motor diameter\n\nE. Model 1772 Universal Holder\n\nF. Model 1771-A-Mod Electrode Holder with Straight Clamp\n\nG. Model 905 Head Alignment Tool (leveling device)\n\nH. Estimated UPS 3 Day freight charges\n\nDISCLAIMER AND ADDITIONAL NOTICES:\n\nResponses may be used as research to better understand the marketplace or for creating a potential future acquisition. Response is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this or future information requests.\n\nAT THIS TIME NO SOLICITATION EXISTS. (DO NOT REQUEST A COPY OF THE SOLICITATION).\n\nThis notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.\n\nNo Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s.)","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26326Q0227","place_of_performance":{"zip":"57105","city":{"code":"59020","name":"Sioux Falls"},"state":{"code":"SD","name":"South Dakota"},"street":"Department of Veterans Affairs Sioux Falls VA Healthcare System","country":{"code":"USA","name":"UNITED STATES"},"street2":"2501 W. 22nd St."},"product_service_code":"6640"}],"due_at":"2026-01-06T16:00:00Z","due_date":"2026-01-06","closes_at":"2026-01-06T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","state":"SD","county":"46099","county_name":"Minnehaha County","city":"4659020","city_name":"Sioux Falls","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-18T04:56:43.547826Z","principal_notice_id":"bdffc965404348bbbc9be1d39253efea","description":{"text":"REQUEST FOR INFORMATION / SOURCES SOUGHT for Stereotaxic Instrument, Brand-Name Only\n\nDEPARTMENT OF VETERANS AFFAIRS, VISN 23 Source Sought: The VA is seeking business sources qualified to provide the items listed below as Brand Name or Equal. This is NOT a solicitation.\n\nINTERESTED SOURCES SHALL RESPOND BY:\n\nPlease submit response no later than 10:00am CST Tuesday, January 06, 2026\n\nAll responses and questions must be emailed to marie.weathers@va.gov and must include in the subject line: Sources Sought Stereotaxic Instrument 36C26326Q0227\n\nPOTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:\n\n1. Company name, address, phone number, primary contact(s), e-mail address.\n\n2. State if your firm distributes the Brand Name items, or Equal items.\n\n3. SAM UEI number.\n\n4. NAICS (North American Industry Classification System) code 339112 that your firm uses for injection pumps and modules.\n\n5. State if your firm is a large business, small business, service-disabled-veteran-owned\nsmall business, veteran-owned small business, HUB zone 8(a), women-owned small business or a small disadvantaged business.\n\n6. State if your firm has the required items on Schedule (FSS, GSA, SEWP, other ).\n\n7. Provide a letter from the manufacturer verifying your firm is an authorized distributor.\n\n8. Provide the country of origin for each of the required items.\n\nREQUIRED ITEM and Salient Characteristics:\nContractor shall provide brand-name only Kopf Instruments:\nModel 942 Small Animal Stereotaxic Instrument with Digital Display Console\nMust allow for X, Y, Z adjustments to include 10-micron resolution and include a compact digital display console. The digital display control must allow the user to zero reset at any position. Metric scale 80 mm calibrated 0.1 mm vernier scale.\nMust ensure that angle adjustment is available through a universal joint calibrated on two planes for access from any angle. Must have the ability to remove the vertical alignment pin to allow angled settings from 0Â° 90Â° either side of vertical, 2Â° increments.\nMust provide rotation adjustment through a manipulator swivel base that can be rotated up to 360Â°. Manipulator X/Z axis must be able to reposition at 90Â° increments.\nThe stereotaxic frame must be mounted to a 13.9 L x 10 W base plate and elevated to bring ear bar height to 53 mm.\nEar bar slots on the U frame must have 0.1 mm verniers for centering the animal. Ear bar zero to posterior end of base plate is 8.763 .\n\nB. Model 923-B Mouse Gas Anesthesia Head Holder\nGas Anesthesia Mask must have an inlet/outlet ports (1/8 dia.)\nMust be compatible with Ear Bar Model 1922 Non-Rupture 60Â° Tip Mouse Ear Bars.\n\nC. Model 921 Zygoma Ear Cups\nMust allow for a 25Â° with 5Â° graduations in tilt for Dorsal/Ventral tilt\nMust provide a 35Â° (5Â° graduations) coronal adjustment\nMust provide a 44mm Adaptor Plate A/P adjustment\n\nD. Model 1474 Stereotaxic Drill includes tabletop\n*** Includes tabletop motor controller, foot pedal, and piece holder.\nMust include tabletop motor controller, foot pedal and piece holder\nDrill size must be 6 in overall length\nMust have a 5/8 grip diameter\nMust have a 1 motor diameter\n\nE. Model 1772 Universal Holder\n\nF. Model 1771-A-Mod Electrode Holder with Straight Clamp\n\nG. Model 905 Head Alignment Tool (leveling device)\n\nH. Estimated UPS 3 Day freight charges\n\nDISCLAIMER AND ADDITIONAL NOTICES:\n\nResponses may be used as research to better understand the marketplace or for creating a potential future acquisition. Response is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this or future information requests.\n\nAT THIS TIME NO SOLICITATION EXISTS. (DO NOT REQUEST A COPY OF THE SOLICITATION).\n\nThis notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.\n\nNo Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s.)","html":"REQUEST FOR INFORMATION / SOURCES SOUGHT for Stereotaxic Instrument, Brand-Name Only\n\nDEPARTMENT OF VETERANS AFFAIRS, VISN 23 Source Sought:  The VA is seeking business sources qualified to provide the items listed below as Brand Name or Equal.  This is NOT a solicitation. \n\nINTERESTED SOURCES SHALL RESPOND BY:\n\nPlease submit response no later than 10:00am CST Tuesday, January 06, 2026\n\nAll responses and questions must be emailed to marie.weathers@va.gov and must include in the subject line:  Sources Sought Stereotaxic Instrument 36C26326Q0227\n\nPOTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:\n\n1. Company name, address, phone number, primary contact(s), e-mail address.\n\n2. State if your firm distributes the Brand Name items, or Equal items. \n\n3. SAM UEI number.\n\n4. NAICS (North American Industry Classification System) code 339112 that your firm uses for injection pumps and modules.\n\n5. State if your firm is a large business, small business, service-disabled-veteran-owned \nsmall business, veteran-owned small business, HUB zone 8(a), women-owned small business or a small disadvantaged business.\n\n 6. State if your firm has the required items on Schedule (FSS, GSA, SEWP, other ).\n\n7. Provide a letter from the manufacturer verifying your firm is an authorized distributor.\n\n 8. Provide the country of origin for each of the required items.\n \nREQUIRED ITEM and Salient Characteristics:\nContractor shall provide brand-name only Kopf Instruments: \n Model 942 Small Animal Stereotaxic Instrument with Digital Display Console\n  Must allow for X, Y, Z adjustments to include 10-micron resolution and include a compact digital display console. The digital display control must allow the user to  zero  reset at any position. Metric scale 80 mm calibrated 0.1 mm vernier scale.\n  Must ensure that angle adjustment is available through a universal joint calibrated on two planes for access from any angle. Must have the ability to remove the vertical alignment pin to allow angled settings from 0Â°   90Â° either side of vertical, 2Â° increments.\n  Must provide rotation adjustment through a manipulator swivel base that can be rotated up to 360Â°. Manipulator X/Z axis must be able to reposition at 90Â° increments. \n  The stereotaxic frame must be mounted to a 13.9 L x 10 W base plate and elevated to bring ear bar height to 53 mm. \n  Ear bar slots on the  U  frame must have 0.1 mm verniers for centering the animal. Ear bar zero to posterior end of base plate is 8.763 .\n\nB. Model 923-B Mouse Gas Anesthesia Head Holder\n  Gas Anesthesia Mask must have an inlet/outlet ports (1/8  dia.)\n  Must be compatible with Ear Bar Model 1922 Non-Rupture 60Â° Tip Mouse Ear Bars.\n\nC. Model 921 Zygoma Ear Cups\n  Must allow for a 25Â° with 5Â° graduations in tilt for Dorsal/Ventral tilt\n  Must provide a 35Â° (5Â° graduations) coronal adjustment\n  Must provide a 44mm Adaptor Plate A/P adjustment\n\nD. Model 1474 Stereotaxic Drill includes tabletop\n*** Includes tabletop motor controller, foot pedal, and piece holder.\n  Must include tabletop motor controller, foot pedal and piece holder\n  Drill size must be 6  in overall length\n  Must have a 5/8  grip diameter\n  Must have a 1  motor diameter\n\nE. Model 1772 Universal Holder\n\nF. Model 1771-A-Mod Electrode Holder with Straight Clamp\n\nG. Model 905 Head Alignment Tool (leveling device)\n\nH. Estimated UPS 3 Day freight charges\n\nDISCLAIMER AND ADDITIONAL NOTICES:\n\nResponses may be used as research to better understand the marketplace or for creating a potential future acquisition.  Response is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this or future information requests.\n\nAT THIS TIME NO SOLICITATION EXISTS.  (DO NOT REQUEST A COPY OF THE SOLICITATION).\n\nThis notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.\n\nNo Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s.)","origin":"detail"},"contacts":[{"name":"Marie Weathers","role":"primary","email":"marie.weathers@va.gov","phone":"605-347-2511","title":"Contracting Officer"}],"place_of_performance":{"zip":"57105","city":{"code":"59020","name":"Sioux Falls"},"state":{"code":"SD","name":"South Dakota"},"street":"Department of Veterans Affairs Sioux Falls VA Healthcare System","country":{"code":"USA","name":"UNITED STATES"},"street2":"2501 W. 22nd St."},"office_address":{"zip":"55101","city":"Saint Paul","state":"MN","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"ac63a26905db4a9eba30674c0537074b","name":"36C26326Q0227.docx","kind":"file","mime_type":".docx","size_bytes":18010,"posted_at":"2025-12-18T19:18:43.204Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ac63a26905db4a9eba30674c0537074b/download","mirrored":false}],"awards":[],"related":[{"key":"36C26327R0007","latest_notice_id":"95bb4c1f961f4f338e8e9b4b060e07cc","title":"W065--V23 Home Oxygen Emergency Bridge Contract (VA-27-00021984)","solicitation_number":"36C26327R0007","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"532283","psc":"W065","set_aside":null,"state":"MN","county":"27037","county_name":"Dakota County","city":"2717288","city_name":"Eagan","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T09:15:14.204648Z"},{"key":"36C26327Q0008","latest_notice_id":"8125dedb922a4a6faede820c70a19007","title":"Minneapolis VA Medical Library Serials & Periodicals Solicitation","solicitation_number":"36C26327Q0008","notice_type":"o","first_type":"o","first_posted":"2026-08-20","last_posted":"2026-11-13","notices":8,"due_at":"2026-11-27T23:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"513120","psc":"7630","set_aside":"SBA","state":"MN","county":"27053","county_name":"Hennepin County","city":"2743000","city_name":"Minneapolis","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26326R0063","latest_notice_id":"d70c843cc4d84fd69905d2e17ce78771","title":"NWI Offsite Pathology Services","solicitation_number":"36C26326R0063","notice_type":"o","first_type":"o","first_posted":"2026-10-09","last_posted":"2026-11-20","notices":5,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"621511","psc":"Q515","set_aside":"SBA","state":"NE","county":"31055","county_name":"Douglas County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26327Q0131","latest_notice_id":"885e687dd48e45c295666a91fc27da2b","title":"6515--Medtronic FT10 Series Cauterizer","solicitation_number":"36C26327Q0131","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":"ND","county":"38017","county_name":"Cass County","city":"3825700","city_name":"Fargo","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"},{"key":"36C26327Q0124","latest_notice_id":"20b13f623c264277af31f93dde8fdcff","title":"J041--Service - AHU PM & Filter Evaluation - NWI","solicitation_number":"36C26327Q0124","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"238220","psc":"J041","set_aside":null,"state":"NE","county":"31055","county_name":"Douglas County","city":"3137000","city_name":"Omaha","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24727Q0119","latest_notice_id":"81776fecabf149c9867d6253acdc2478","title":"Vivarium Tunnel Washer","solicitation_number":"36C24727Q0119","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T13:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T13:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C247","office_name":"247-NETWORK CONTRACT OFFICE 7 (36C247)","naics":"339112","psc":"6640","set_aside":null,"state":"GA","county":"13089","county_name":"DeKalb County","city":"1322052","city_name":"Decatur","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"}],"similar_open_total":15,"indexable":false}