{"canonical":"https://sealedbidder.com/opportunities/36c26325q1047","key":"36C26325Q1047","url":"https://sealedbidder.com/opportunities/36c26325q1047","title":"J041--Service - Fire Damper Inspection - SF IDIQ - Ordering Periods 09-30-2025","solicitation_number":"36C26325Q1047","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-08-08T16:00:00Z","first_posted":"2025-07-28","last_posted":"2025-07-28","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"238220","psc":"J041","set_aside":"SDVOSBC","place_state":"SD","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"46099","place_county_name":"Minnehaha County","place_city":"4659020","place_city_name":"Sioux Falls","winner":null,"award_amount":null,"publications":[{"notice_id":"07be6199c63248b6b4b6598a7a154afe","title":"J041--Service - Fire Damper Inspection - SF IDIQ - Ordering Periods 09-30-2025","solicitation_number":"36C26325Q1047","notice_type":"r","base_type":"r","posted":"2025-07-28","posted_at":"2025-07-29T00:51:03.443Z","due_at":"2025-08-08T16:00:00Z","due_date":"2025-08-08","cancelled":false,"archived":true,"archive_date":"2025-09-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/07be6199c63248b6b4b6598a7a154afe/view","enriched":true,"history":[{"index":3,"title":"J041--Service - Fire Damper Inspection - SF IDIQ - Ordering Periods 09-30-2025","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-29T00:51:03.443Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"07be6199c63248b6b4b6598a7a154afe","solicitation_number":"36C26325Q1047"}]}],"latest_notice_id":"07be6199c63248b6b4b6598a7a154afe","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-07-28","posted_at":"2025-07-29T00:51:03.443Z","created_at":"2025-07-29T00:50:49.134Z","modified_at":"2025-09-08T04:00:15.246Z","response_deadline":{"raw":"2025-08-08T11:00:00-05:00","utc":"2025-08-08T16:00:00Z","date":"2025-08-08","time":"11:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/07be6199c63248b6b4b6598a7a154afe/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"J041--Service - Fire Damper Inspection - SF IDIQ - Ordering Periods 09-30-2025","agency":{"office":{"code":"36C263","name":"NETWORK CONTRACT OFFICE 23 (36C263)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"55101","city":"Saint Paul","state":"MN","country":"USA"},"organization_id":"100183219","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-07","archive_type":"auto_custom"},"history":[{"index":3,"title":"J041--Service - Fire Damper Inspection - SF IDIQ - Ordering Periods 09-30-2025","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-29T00:51:03.443Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"07be6199c63248b6b4b6598a7a154afe","solicitation_number":"36C26325Q1047"}],"contacts":[{"name":"Michael Wicht","role":"primary","email":"Michael.wicht@va.gov","phone":"4029963630","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"07be6199c63248b6b4b6598a7a154afe","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"07be6199c63248b6b4b6598a7a154afe","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-07T03:33:26.354719948Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"840f957cbda8b4c75a432ea090a42af79d2509c9e5c66af70acc14637b4e6700","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-07T03:33:26.354719948Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought\n\nPage 2 of 2\n\nThis is a request for information only and it is not a solicitation announcement.\nThe purpose of this sources sought notice is to gain knowledge of qualified potential contractors and their socio-economic size classification in accordance with NAICS code 238220.\nNAICS Code 238220   Plumbing heating and air conditioning.\nResponses will be used by the Government to make appropriate acquisition decisions.\nStatement of Work:\nFire, Smoke, and Combination Fire/Smoke Damper Testing Sioux Falls VA Healthcare System\nSee the (Functional/Performance/Specification below.\nThe scope of this SOW is the procurement of a Service Agreement to provide inspection and testing of the fire, smoke, and combination fire/smoke dampers at the Sioux Falls V.A. Healthcare System, Sioux Falls South Dakota according to the terms and conditions stated herein.\nPERFORMANCE:\nThe contractor shall provide appropriate number of trips to the Sioux Falls V.A. Healthcare Systems in Sioux Falls South Dakota during the Service Agreement period to perform the inspection/testing during our business hours. See Hours of Services section below. Testing in critical areas may be required to occur during non-business hours. These activities will be coordinated with the service lines through the Contracting Officers Representative.\nContractor shall request in writing to COR a minimum of 2-weeks prior to when the activities are desired to occur, and when anticipating to move into a new area, to allow for service line coordination. Actual time given to the contractor tom complete activities will be dependent on operational requirements of the service line. Prior to the start of activities, the contractor will be required to attend a Preconstruction Risk Assessment (PCRA) and implement any protective measures deemed required by the PCRA.\nHOURS OF SERVICES:\nThe Contractor shall perform the services as specified herein Monday through Friday with the exception of National Holidays between the hours of 8:00a.m.   4:30p.m.\nGOVERNMENT NATIONAL HOLIDAYS:\nThe Contractor is not required to provide services on the following national holidays nor shall the Contractor be paid for these holidays unless previously coordinated with the COR:\n\nNew Year s Day\nJanuary 1\nMartin Luther King  s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeterans Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25\n\nWhen a holiday falls on a Sunday, the following Monday will be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by the\nU.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\nContractor Responsibilities:\nThe Contractor shall take all precautions necessary to protect against injury or damage during the performance of this contract. The Contractor shall be responsible for any injury to Contractor s employees as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by contractor s employees  fault or negligence.\nContractor shall coordinate a work schedule with the VA contact. Work may be required to be performed outside of normal duty hours as required by hospital operations. Any work resulting in hours outside of 8:00am to 4:30pm CT because of operational impacts shall occur at no additional expense to the Government.\nContractor shall provide personnel on-site at the SFVAHCS to perform services under this Statement of Work within 10 calendar days of request.\nContractor shall respond within five (5) calendar days to SFVAHCS inquiries or questions and provide revised documents (if necessary).\nThe contractor shall provide all labor, resources, and travel necessary to complete the services as required within this statement of work.\nTechnicians shall provide all tools and labor necessary to perform inspections, installations, repairs, as required by this statement of work.\nSafety Requirements: The Contractor shall be responsible for providing safety measures to conduct the work. The Contractor shall comply with all VA and OSHA safety and security measure such as, the lock-out-tag program and special work permits. The contractor is also required to coordinate with the VATR or designee to gain access to the specific work area along with obtaining identification badges for all personnel prior to commencement of services.\nIt shall be understood that, throughout performance of the contract, the Contractor s personnel, while on VA property, shall adhere to all requirements and regulations that govern the VA Health Care System and its property.\nAmong all other requirements, the VA Health Care System and its property is entirely smoke- free.\nContractor and their personnel shall follow all U.S. Department of Veterans Affairs (VA) policies, standard operating procedures, applicable laws, and applicable regulations while on VA property. Violations of this may result in citation and disciplinary measures for persons violating the law.\nContractor and their personnel shall always wear visible identification while they are on premises.\nPossession of weapons is prohibited.\nContractor shall take all reasonable precautions necessary to protect persons and property from injury or damage during the performance of this contract.\nSFVAHCS Responsibilities:\nProvide AutoCAD and PDF formats of damper locations.\nProvide excel spreadsheet which will be used as a shared resource to update inventories, track findings, and everything necessary for documentation purposes for this contract.\nSFVAHCS will consider requests made by the contractor that are considered reasonable by SFVAHCS and have been presented in writing as indicated in paragraph 2.2\nCONTRACTOR PERSONNEL ACCEPTANCE: The Government reserves the right to accept or reject Contractor s staff for the rendering of services. Complaints concerning Contract Personnel s performance or conduct shall be dealt with by the Contractor, VA representative and the final decision made by the Contracting Officer.\nOverall reporting requirements\nSpreadsheet:\nContractor shall track changes in provided excel spreadsheet to aid in updating VHA records.\nDrawings:\nProvide updated drawings in AutoCAD and pdf format.\nField Verification (CLIN1)\nApplicable to Active Fire, Active Smoke, and Abandoned Fire dampers.\nConfirm access for each damper and document deficiencies. Note which access panel or inspection fitting from paragraph 9 provide access to inspect damper for inaccessible dampers.\nConfirm damper at location can be tested or witnessed from access point.\nLabel every damper on the VA provided inventory and any found that are not included in the inventory in the  Description/Location  column.\nRed background with white font. Size 12 print minimum.\nDampers above lay-in ceilings.\nCeiling grid labeled with damper number found in spreadsheet. 7.1.3.1.1.2. Damper labeled above ceiling with damper number found in\nspreadsheet.\nDampers in mechanical room areas.\nLabel by applicable access panel with damper number found in spreadsheet.\nContractor shall remove all old labels found for all dampers covered by this statement of work.\nRelocate fire alarm devices to gain access as required.\nReporting:\nUpdate details in VA provided spreadsheet where found incorrect, incomplete or in addition to existing information in the description column.\nDuct size\nWhat ductwork is serving. Supply air, exhaust air, and return air.\nDescription where to find damper.\nRoom number.\n\nDamper orientation (Vertical = perpendicular to ground and Horizontal = parallel to ground).\nEliminate duplicates.\nDocument access in the  deficiencies  column for each damper in VA provided spreadsheet. Include details for which damper access device size would provide access to observe or test damper. Contractor must note largest possible access panel that ductwork can support.\nInspection and Testing\nAbandoned Damper inspection (CLIN2)\nApplicable to abandoned Fire dampers.\nConfirm fire dampers are closed at locations identified in inventory.\nReporting:\nDocument observations in VA provided spreadsheet.\nSmoke and Fire/Smoke Damper Testing and Inspection (CLIN3)\nApplicable to Fire/Smoke dampers.\nTest as per current adopted NFPA 80 requirements\nContractor shall include personal required to operate fire alarm panel.\nContractor shall include personal required to safely operate elevators for contractor to access dampers in elevator shafts.\nReporting:\nDocument observations in VA provided spreadsheet for all eight entries for inspection of damper.\nFire damper Testing and Inspection (CLIN4)\nApplicable to active Fire dampers.\nTest as per current adopted NFPA 80 requirements.\nReporting:\nDocument observations in VA provided spreadsheet for all entries for inspection of damper.\nParts for repair (CLIN9)\nIf repairs resultant from inspections are identified, the Contractor shall provide all replacement parts needed to keep the failed component in operating condition as originally designed by the manufacturer. Parts may be repaired or replaced, as the contractor deems appropriate, so long as amount listed in CLINs for Parts Repair cited in Section B.2 (Price/Cost Schedule) are not exceeded. No used parts will be used to repair this equipment.\nFor repairs, Contractor shall furnish the VATR with a written estimate of the cost to make necessary repairs. Contractor shall also provide a comparison quote to the VATR for what that item would have cost for commercial pricing so Government has basis for making price fair and reasonableness determination, or as alternative, Contractor shall provide a quote\n\nprovided to another federal agency for similar item for determination purposes. If cost exceeds cost listed for applicable line item in Section B.2 (Price/Cost Schedule), the Contracting Officer shall consider issuing a bilateral contract modification to increase funding for this line item per coordination with VATR, that includes supporting documentation as cited above.\nAccess Panels\nSmall access panel (CLIN5)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 6/6, 8/8, or 10/10.\nSquare door with double cam.1\nMedium access panel (CLIN6)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 10/10, 12/12, or 14/14.\nSquare door with double cam.1\nLarge access panel (CLIN7)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 16/16, 18/18, 20/20, 22/22 or 24/24.\nSquare door with double cam.1\nAccess Panel Requirements: Ductmate industries or approved equal double cam access doors. To provide easy access into air ducts and units. This door was developed as an inexpensive alternative to the Ductmate SandwichÂ® Access Door, for low pressure applications.\nTECHNICAL INFORMATION:\nDOOR Consists of two, 24 gauge galvanized steel panels mechanically locked together\nINSULATION 1  High density fiberglass insulation with UL classification: FHC25/50 and R-value 4.2.\nGASKET Closed cell cross-linked polyethylene gasket with a service temperature range of -70Â°F to 175Â°F. The gasket is bonded to the inside of both the Dovetail and Press-On frames and also to the outside of the Dovetail frame only. Double Sided Adhesive Gasket: Closed cell cross-linked polyethylene is UL94HF1 listed with a service temperature range of -110Â°F to 158Â°F. This gasket is bonded to the outside of the Press-On frame only.\nDOVETAIL FRAME Frames measuring 6  x 6  to 12  x 12  are manufactured from 24 gauge galvanized steel. Frames measuring 14  x 14  to 24  x 24  are manufactured from 22 gauge galvanized steel. All frames are manufactured with fastened corners for increased strength and an improved Dovetail design for easy installation on Metal Duct, 1  Duct Board or 1Â½  Duct Board.\n\nPRESS-ON FRAME Frames measuring 6  x 6  to 12  x 12  are manufactured from 24 gauge galvanized steel. Frames measuring 14  x 14  to 24  x 24  are manufactured from 22 gauge galvanized steel. A durable double sided adhesive gasket allows for easy installation to metal ductwork.\nCAM & LATCH The cam is manufactured from 16 gauge galvanized steel and the latch is manufactured from 20 gauge galvanized steel. Each cam is secured to the door with a rivet. The latch is securely fastened to the frame.\nCamera Inspection Instrument Fitting (CLIN8)\nContractor shall provide, modify ductwork, patch and repair insulation, and install instrument test fittings.\nInstrument Test Fitting Requirements: Manufactured type with a minimum 50 mm (2 inch) length for insulated duct, and a minimum 25 mm (1 inch) length for duct not insulated. Test hole shall have a flat gasket for rectangular ducts and a concave gasket for round ducts at the base, and a screw cap to prevent air leakage.\nBADGES AND PARKING:\nAll Contractor personnel are required to wear identification (I.D.) badges issued by the SFVAHCS Engineering office during the entire time they are on the SFVAHCS grounds.\nIt is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the SFVAHCS security office. The SFVAHCS shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstance.\nAUTHORIZED SERVICES:\nOnly those services specified herein are authorized under this contract. Prior to performing any service of a non-contract nature, the Contracting Officer (CO) must be advised of the reasons for this additional work. Only the Contracting Officer may authorize additional services, and reimbursement will not be made unless prior authorization has been obtained.\nATTACHMENTS:\nAttachment A: Damper Location Drawings (Bldgs. 1,5 and 54)\nAttachment B: Current Damper Inventory Tracker","text":"Sources Sought\n\nPage 2 of 2\n\nThis is a request for information only and it is not a solicitation announcement.\nThe purpose of this sources sought notice is to gain knowledge of qualified potential contractors and their socio-economic size classification in accordance with NAICS code 238220.\nNAICS Code 238220 Plumbing heating and air conditioning.\nResponses will be used by the Government to make appropriate acquisition decisions.\nStatement of Work:\nFire, Smoke, and Combination Fire/Smoke Damper Testing Sioux Falls VA Healthcare System\nSee the (Functional/Performance/Specification below.\nThe scope of this SOW is the procurement of a Service Agreement to provide inspection and testing of the fire, smoke, and combination fire/smoke dampers at the Sioux Falls V.A. Healthcare System, Sioux Falls South Dakota according to the terms and conditions stated herein.\nPERFORMANCE:\nThe contractor shall provide appropriate number of trips to the Sioux Falls V.A. Healthcare Systems in Sioux Falls South Dakota during the Service Agreement period to perform the inspection/testing during our business hours. See Hours of Services section below. Testing in critical areas may be required to occur during non-business hours. These activities will be coordinated with the service lines through the Contracting Officers Representative.\nContractor shall request in writing to COR a minimum of 2-weeks prior to when the activities are desired to occur, and when anticipating to move into a new area, to allow for service line coordination. Actual time given to the contractor tom complete activities will be dependent on operational requirements of the service line. Prior to the start of activities, the contractor will be required to attend a Preconstruction Risk Assessment (PCRA) and implement any protective measures deemed required by the PCRA.\nHOURS OF SERVICES:\nThe Contractor shall perform the services as specified herein Monday through Friday with the exception of National Holidays between the hours of 8:00a.m. 4:30p.m.\nGOVERNMENT NATIONAL HOLIDAYS:\nThe Contractor is not required to provide services on the following national holidays nor shall the Contractor be paid for these holidays unless previously coordinated with the COR:\n\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeterans Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25\n\nWhen a holiday falls on a Sunday, the following Monday will be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by the\nU.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\nContractor Responsibilities:\nThe Contractor shall take all precautions necessary to protect against injury or damage during the performance of this contract. The Contractor shall be responsible for any injury to Contractor s employees as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by contractor s employees fault or negligence.\nContractor shall coordinate a work schedule with the VA contact. Work may be required to be performed outside of normal duty hours as required by hospital operations. Any work resulting in hours outside of 8:00am to 4:30pm CT because of operational impacts shall occur at no additional expense to the Government.\nContractor shall provide personnel on-site at the SFVAHCS to perform services under this Statement of Work within 10 calendar days of request.\nContractor shall respond within five (5) calendar days to SFVAHCS inquiries or questions and provide revised documents (if necessary).\nThe contractor shall provide all labor, resources, and travel necessary to complete the services as required within this statement of work.\nTechnicians shall provide all tools and labor necessary to perform inspections, installations, repairs, as required by this statement of work.\nSafety Requirements: The Contractor shall be responsible for providing safety measures to conduct the work. The Contractor shall comply with all VA and OSHA safety and security measure such as, the lock-out-tag program and special work permits. The contractor is also required to coordinate with the VATR or designee to gain access to the specific work area along with obtaining identification badges for all personnel prior to commencement of services.\nIt shall be understood that, throughout performance of the contract, the Contractor s personnel, while on VA property, shall adhere to all requirements and regulations that govern the VA Health Care System and its property.\nAmong all other requirements, the VA Health Care System and its property is entirely smoke- free.\nContractor and their personnel shall follow all U.S. Department of Veterans Affairs (VA) policies, standard operating procedures, applicable laws, and applicable regulations while on VA property. Violations of this may result in citation and disciplinary measures for persons violating the law.\nContractor and their personnel shall always wear visible identification while they are on premises.\nPossession of weapons is prohibited.\nContractor shall take all reasonable precautions necessary to protect persons and property from injury or damage during the performance of this contract.\nSFVAHCS Responsibilities:\nProvide AutoCAD and PDF formats of damper locations.\nProvide excel spreadsheet which will be used as a shared resource to update inventories, track findings, and everything necessary for documentation purposes for this contract.\nSFVAHCS will consider requests made by the contractor that are considered reasonable by SFVAHCS and have been presented in writing as indicated in paragraph 2.2\nCONTRACTOR PERSONNEL ACCEPTANCE: The Government reserves the right to accept or reject Contractor s staff for the rendering of services. Complaints concerning Contract Personnel s performance or conduct shall be dealt with by the Contractor, VA representative and the final decision made by the Contracting Officer.\nOverall reporting requirements\nSpreadsheet:\nContractor shall track changes in provided excel spreadsheet to aid in updating VHA records.\nDrawings:\nProvide updated drawings in AutoCAD and pdf format.\nField Verification (CLIN1)\nApplicable to Active Fire, Active Smoke, and Abandoned Fire dampers.\nConfirm access for each damper and document deficiencies. Note which access panel or inspection fitting from paragraph 9 provide access to inspect damper for inaccessible dampers.\nConfirm damper at location can be tested or witnessed from access point.\nLabel every damper on the VA provided inventory and any found that are not included in the inventory in the Description/Location column.\nRed background with white font. Size 12 print minimum.\nDampers above lay-in ceilings.\nCeiling grid labeled with damper number found in spreadsheet. 7.1.3.1.1.2. Damper labeled above ceiling with damper number found in\nspreadsheet.\nDampers in mechanical room areas.\nLabel by applicable access panel with damper number found in spreadsheet.\nContractor shall remove all old labels found for all dampers covered by this statement of work.\nRelocate fire alarm devices to gain access as required.\nReporting:\nUpdate details in VA provided spreadsheet where found incorrect, incomplete or in addition to existing information in the description column.\nDuct size\nWhat ductwork is serving. Supply air, exhaust air, and return air.\nDescription where to find damper.\nRoom number.\n\nDamper orientation (Vertical = perpendicular to ground and Horizontal = parallel to ground).\nEliminate duplicates.\nDocument access in the deficiencies column for each damper in VA provided spreadsheet. Include details for which damper access device size would provide access to observe or test damper. Contractor must note largest possible access panel that ductwork can support.\nInspection and Testing\nAbandoned Damper inspection (CLIN2)\nApplicable to abandoned Fire dampers.\nConfirm fire dampers are closed at locations identified in inventory.\nReporting:\nDocument observations in VA provided spreadsheet.\nSmoke and Fire/Smoke Damper Testing and Inspection (CLIN3)\nApplicable to Fire/Smoke dampers.\nTest as per current adopted NFPA 80 requirements\nContractor shall include personal required to operate fire alarm panel.\nContractor shall include personal required to safely operate elevators for contractor to access dampers in elevator shafts.\nReporting:\nDocument observations in VA provided spreadsheet for all eight entries for inspection of damper.\nFire damper Testing and Inspection (CLIN4)\nApplicable to active Fire dampers.\nTest as per current adopted NFPA 80 requirements.\nReporting:\nDocument observations in VA provided spreadsheet for all entries for inspection of damper.\nParts for repair (CLIN9)\nIf repairs resultant from inspections are identified, the Contractor shall provide all replacement parts needed to keep the failed component in operating condition as originally designed by the manufacturer. Parts may be repaired or replaced, as the contractor deems appropriate, so long as amount listed in CLINs for Parts Repair cited in Section B.2 (Price/Cost Schedule) are not exceeded. No used parts will be used to repair this equipment.\nFor repairs, Contractor shall furnish the VATR with a written estimate of the cost to make necessary repairs. Contractor shall also provide a comparison quote to the VATR for what that item would have cost for commercial pricing so Government has basis for making price fair and reasonableness determination, or as alternative, Contractor shall provide a quote\n\nprovided to another federal agency for similar item for determination purposes. If cost exceeds cost listed for applicable line item in Section B.2 (Price/Cost Schedule), the Contracting Officer shall consider issuing a bilateral contract modification to increase funding for this line item per coordination with VATR, that includes supporting documentation as cited above.\nAccess Panels\nSmall access panel (CLIN5)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 6/6, 8/8, or 10/10.\nSquare door with double cam.1\nMedium access panel (CLIN6)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 10/10, 12/12, or 14/14.\nSquare door with double cam.1\nLarge access panel (CLIN7)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 16/16, 18/18, 20/20, 22/22 or 24/24.\nSquare door with double cam.1\nAccess Panel Requirements: Ductmate industries or approved equal double cam access doors. To provide easy access into air ducts and units. This door was developed as an inexpensive alternative to the Ductmate SandwichÂ® Access Door, for low pressure applications.\nTECHNICAL INFORMATION:\nDOOR Consists of two, 24 gauge galvanized steel panels mechanically locked together\nINSULATION 1 High density fiberglass insulation with UL classification: FHC25/50 and R-value 4.2.\nGASKET Closed cell cross-linked polyethylene gasket with a service temperature range of -70Â°F to 175Â°F. The gasket is bonded to the inside of both the Dovetail and Press-On frames and also to the outside of the Dovetail frame only. Double Sided Adhesive Gasket: Closed cell cross-linked polyethylene is UL94HF1 listed with a service temperature range of -110Â°F to 158Â°F. This gasket is bonded to the outside of the Press-On frame only.\nDOVETAIL FRAME Frames measuring 6 x 6 to 12 x 12 are manufactured from 24 gauge galvanized steel. Frames measuring 14 x 14 to 24 x 24 are manufactured from 22 gauge galvanized steel. All frames are manufactured with fastened corners for increased strength and an improved Dovetail design for easy installation on Metal Duct, 1 Duct Board or 1Â½ Duct Board.\n\nPRESS-ON FRAME Frames measuring 6 x 6 to 12 x 12 are manufactured from 24 gauge galvanized steel. Frames measuring 14 x 14 to 24 x 24 are manufactured from 22 gauge galvanized steel. A durable double sided adhesive gasket allows for easy installation to metal ductwork.\nCAM & LATCH The cam is manufactured from 16 gauge galvanized steel and the latch is manufactured from 20 gauge galvanized steel. Each cam is secured to the door with a rivet. The latch is securely fastened to the frame.\nCamera Inspection Instrument Fitting (CLIN8)\nContractor shall provide, modify ductwork, patch and repair insulation, and install instrument test fittings.\nInstrument Test Fitting Requirements: Manufactured type with a minimum 50 mm (2 inch) length for insulated duct, and a minimum 25 mm (1 inch) length for duct not insulated. Test hole shall have a flat gasket for rectangular ducts and a concave gasket for round ducts at the base, and a screw cap to prevent air leakage.\nBADGES AND PARKING:\nAll Contractor personnel are required to wear identification (I.D.) badges issued by the SFVAHCS Engineering office during the entire time they are on the SFVAHCS grounds.\nIt is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the SFVAHCS security office. The SFVAHCS shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstance.\nAUTHORIZED SERVICES:\nOnly those services specified herein are authorized under this contract. Prior to performing any service of a non-contract nature, the Contracting Officer (CO) must be advised of the reasons for this additional work. Only the Contracting Officer may authorize additional services, and reimbursement will not be made unless prior authorization has been obtained.\nATTACHMENTS:\nAttachment A: Damper Location Drawings (Bldgs. 1,5 and 54)\nAttachment B: Current Damper Inventory Tracker","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26325Q1047","place_of_performance":{"zip":"57105","city":{"code":"59020","name":"Sioux Falls"},"state":{"code":"SD","name":"South Dakota"},"street":"Sioux Falls VA Health Care System","country":{"code":"USA","name":"UNITED STATES"},"street2":"2501 West 22nd Street"},"product_service_code":"J041"}],"due_at":"2025-08-08T16:00:00Z","due_date":"2025-08-08","closes_at":"2025-08-08T16:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","state":"SD","county":"46099","county_name":"Minnehaha County","city":"4659020","city_name":"Sioux Falls","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-07T04:14:40.554925Z","principal_notice_id":"07be6199c63248b6b4b6598a7a154afe","description":{"text":"Sources Sought\n\nPage 2 of 2\n\nThis is a request for information only and it is not a solicitation announcement.\nThe purpose of this sources sought notice is to gain knowledge of qualified potential contractors and their socio-economic size classification in accordance with NAICS code 238220.\nNAICS Code 238220 Plumbing heating and air conditioning.\nResponses will be used by the Government to make appropriate acquisition decisions.\nStatement of Work:\nFire, Smoke, and Combination Fire/Smoke Damper Testing Sioux Falls VA Healthcare System\nSee the (Functional/Performance/Specification below.\nThe scope of this SOW is the procurement of a Service Agreement to provide inspection and testing of the fire, smoke, and combination fire/smoke dampers at the Sioux Falls V.A. Healthcare System, Sioux Falls South Dakota according to the terms and conditions stated herein.\nPERFORMANCE:\nThe contractor shall provide appropriate number of trips to the Sioux Falls V.A. Healthcare Systems in Sioux Falls South Dakota during the Service Agreement period to perform the inspection/testing during our business hours. See Hours of Services section below. Testing in critical areas may be required to occur during non-business hours. These activities will be coordinated with the service lines through the Contracting Officers Representative.\nContractor shall request in writing to COR a minimum of 2-weeks prior to when the activities are desired to occur, and when anticipating to move into a new area, to allow for service line coordination. Actual time given to the contractor tom complete activities will be dependent on operational requirements of the service line. Prior to the start of activities, the contractor will be required to attend a Preconstruction Risk Assessment (PCRA) and implement any protective measures deemed required by the PCRA.\nHOURS OF SERVICES:\nThe Contractor shall perform the services as specified herein Monday through Friday with the exception of National Holidays between the hours of 8:00a.m. 4:30p.m.\nGOVERNMENT NATIONAL HOLIDAYS:\nThe Contractor is not required to provide services on the following national holidays nor shall the Contractor be paid for these holidays unless previously coordinated with the COR:\n\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeterans Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25\n\nWhen a holiday falls on a Sunday, the following Monday will be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by the\nU.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\nContractor Responsibilities:\nThe Contractor shall take all precautions necessary to protect against injury or damage during the performance of this contract. The Contractor shall be responsible for any injury to Contractor s employees as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by contractor s employees fault or negligence.\nContractor shall coordinate a work schedule with the VA contact. Work may be required to be performed outside of normal duty hours as required by hospital operations. Any work resulting in hours outside of 8:00am to 4:30pm CT because of operational impacts shall occur at no additional expense to the Government.\nContractor shall provide personnel on-site at the SFVAHCS to perform services under this Statement of Work within 10 calendar days of request.\nContractor shall respond within five (5) calendar days to SFVAHCS inquiries or questions and provide revised documents (if necessary).\nThe contractor shall provide all labor, resources, and travel necessary to complete the services as required within this statement of work.\nTechnicians shall provide all tools and labor necessary to perform inspections, installations, repairs, as required by this statement of work.\nSafety Requirements: The Contractor shall be responsible for providing safety measures to conduct the work. The Contractor shall comply with all VA and OSHA safety and security measure such as, the lock-out-tag program and special work permits. The contractor is also required to coordinate with the VATR or designee to gain access to the specific work area along with obtaining identification badges for all personnel prior to commencement of services.\nIt shall be understood that, throughout performance of the contract, the Contractor s personnel, while on VA property, shall adhere to all requirements and regulations that govern the VA Health Care System and its property.\nAmong all other requirements, the VA Health Care System and its property is entirely smoke- free.\nContractor and their personnel shall follow all U.S. Department of Veterans Affairs (VA) policies, standard operating procedures, applicable laws, and applicable regulations while on VA property. Violations of this may result in citation and disciplinary measures for persons violating the law.\nContractor and their personnel shall always wear visible identification while they are on premises.\nPossession of weapons is prohibited.\nContractor shall take all reasonable precautions necessary to protect persons and property from injury or damage during the performance of this contract.\nSFVAHCS Responsibilities:\nProvide AutoCAD and PDF formats of damper locations.\nProvide excel spreadsheet which will be used as a shared resource to update inventories, track findings, and everything necessary for documentation purposes for this contract.\nSFVAHCS will consider requests made by the contractor that are considered reasonable by SFVAHCS and have been presented in writing as indicated in paragraph 2.2\nCONTRACTOR PERSONNEL ACCEPTANCE: The Government reserves the right to accept or reject Contractor s staff for the rendering of services. Complaints concerning Contract Personnel s performance or conduct shall be dealt with by the Contractor, VA representative and the final decision made by the Contracting Officer.\nOverall reporting requirements\nSpreadsheet:\nContractor shall track changes in provided excel spreadsheet to aid in updating VHA records.\nDrawings:\nProvide updated drawings in AutoCAD and pdf format.\nField Verification (CLIN1)\nApplicable to Active Fire, Active Smoke, and Abandoned Fire dampers.\nConfirm access for each damper and document deficiencies. Note which access panel or inspection fitting from paragraph 9 provide access to inspect damper for inaccessible dampers.\nConfirm damper at location can be tested or witnessed from access point.\nLabel every damper on the VA provided inventory and any found that are not included in the inventory in the Description/Location column.\nRed background with white font. Size 12 print minimum.\nDampers above lay-in ceilings.\nCeiling grid labeled with damper number found in spreadsheet. 7.1.3.1.1.2. Damper labeled above ceiling with damper number found in\nspreadsheet.\nDampers in mechanical room areas.\nLabel by applicable access panel with damper number found in spreadsheet.\nContractor shall remove all old labels found for all dampers covered by this statement of work.\nRelocate fire alarm devices to gain access as required.\nReporting:\nUpdate details in VA provided spreadsheet where found incorrect, incomplete or in addition to existing information in the description column.\nDuct size\nWhat ductwork is serving. Supply air, exhaust air, and return air.\nDescription where to find damper.\nRoom number.\n\nDamper orientation (Vertical = perpendicular to ground and Horizontal = parallel to ground).\nEliminate duplicates.\nDocument access in the deficiencies column for each damper in VA provided spreadsheet. Include details for which damper access device size would provide access to observe or test damper. Contractor must note largest possible access panel that ductwork can support.\nInspection and Testing\nAbandoned Damper inspection (CLIN2)\nApplicable to abandoned Fire dampers.\nConfirm fire dampers are closed at locations identified in inventory.\nReporting:\nDocument observations in VA provided spreadsheet.\nSmoke and Fire/Smoke Damper Testing and Inspection (CLIN3)\nApplicable to Fire/Smoke dampers.\nTest as per current adopted NFPA 80 requirements\nContractor shall include personal required to operate fire alarm panel.\nContractor shall include personal required to safely operate elevators for contractor to access dampers in elevator shafts.\nReporting:\nDocument observations in VA provided spreadsheet for all eight entries for inspection of damper.\nFire damper Testing and Inspection (CLIN4)\nApplicable to active Fire dampers.\nTest as per current adopted NFPA 80 requirements.\nReporting:\nDocument observations in VA provided spreadsheet for all entries for inspection of damper.\nParts for repair (CLIN9)\nIf repairs resultant from inspections are identified, the Contractor shall provide all replacement parts needed to keep the failed component in operating condition as originally designed by the manufacturer. Parts may be repaired or replaced, as the contractor deems appropriate, so long as amount listed in CLINs for Parts Repair cited in Section B.2 (Price/Cost Schedule) are not exceeded. No used parts will be used to repair this equipment.\nFor repairs, Contractor shall furnish the VATR with a written estimate of the cost to make necessary repairs. Contractor shall also provide a comparison quote to the VATR for what that item would have cost for commercial pricing so Government has basis for making price fair and reasonableness determination, or as alternative, Contractor shall provide a quote\n\nprovided to another federal agency for similar item for determination purposes. If cost exceeds cost listed for applicable line item in Section B.2 (Price/Cost Schedule), the Contracting Officer shall consider issuing a bilateral contract modification to increase funding for this line item per coordination with VATR, that includes supporting documentation as cited above.\nAccess Panels\nSmall access panel (CLIN5)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 6/6, 8/8, or 10/10.\nSquare door with double cam.1\nMedium access panel (CLIN6)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 10/10, 12/12, or 14/14.\nSquare door with double cam.1\nLarge access panel (CLIN7)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 16/16, 18/18, 20/20, 22/22 or 24/24.\nSquare door with double cam.1\nAccess Panel Requirements: Ductmate industries or approved equal double cam access doors. To provide easy access into air ducts and units. This door was developed as an inexpensive alternative to the Ductmate SandwichÂ® Access Door, for low pressure applications.\nTECHNICAL INFORMATION:\nDOOR Consists of two, 24 gauge galvanized steel panels mechanically locked together\nINSULATION 1 High density fiberglass insulation with UL classification: FHC25/50 and R-value 4.2.\nGASKET Closed cell cross-linked polyethylene gasket with a service temperature range of -70Â°F to 175Â°F. The gasket is bonded to the inside of both the Dovetail and Press-On frames and also to the outside of the Dovetail frame only. Double Sided Adhesive Gasket: Closed cell cross-linked polyethylene is UL94HF1 listed with a service temperature range of -110Â°F to 158Â°F. This gasket is bonded to the outside of the Press-On frame only.\nDOVETAIL FRAME Frames measuring 6 x 6 to 12 x 12 are manufactured from 24 gauge galvanized steel. Frames measuring 14 x 14 to 24 x 24 are manufactured from 22 gauge galvanized steel. All frames are manufactured with fastened corners for increased strength and an improved Dovetail design for easy installation on Metal Duct, 1 Duct Board or 1Â½ Duct Board.\n\nPRESS-ON FRAME Frames measuring 6 x 6 to 12 x 12 are manufactured from 24 gauge galvanized steel. Frames measuring 14 x 14 to 24 x 24 are manufactured from 22 gauge galvanized steel. A durable double sided adhesive gasket allows for easy installation to metal ductwork.\nCAM & LATCH The cam is manufactured from 16 gauge galvanized steel and the latch is manufactured from 20 gauge galvanized steel. Each cam is secured to the door with a rivet. The latch is securely fastened to the frame.\nCamera Inspection Instrument Fitting (CLIN8)\nContractor shall provide, modify ductwork, patch and repair insulation, and install instrument test fittings.\nInstrument Test Fitting Requirements: Manufactured type with a minimum 50 mm (2 inch) length for insulated duct, and a minimum 25 mm (1 inch) length for duct not insulated. Test hole shall have a flat gasket for rectangular ducts and a concave gasket for round ducts at the base, and a screw cap to prevent air leakage.\nBADGES AND PARKING:\nAll Contractor personnel are required to wear identification (I.D.) badges issued by the SFVAHCS Engineering office during the entire time they are on the SFVAHCS grounds.\nIt is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the SFVAHCS security office. The SFVAHCS shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstance.\nAUTHORIZED SERVICES:\nOnly those services specified herein are authorized under this contract. Prior to performing any service of a non-contract nature, the Contracting Officer (CO) must be advised of the reasons for this additional work. Only the Contracting Officer may authorize additional services, and reimbursement will not be made unless prior authorization has been obtained.\nATTACHMENTS:\nAttachment A: Damper Location Drawings (Bldgs. 1,5 and 54)\nAttachment B: Current Damper Inventory Tracker","html":"Sources Sought\n\nPage 2 of 2\n\nThis is a request for information only and it is not a solicitation announcement.\nThe purpose of this sources sought notice is to gain knowledge of qualified potential contractors and their socio-economic size classification in accordance with NAICS code 238220.\nNAICS Code 238220   Plumbing heating and air conditioning.\nResponses will be used by the Government to make appropriate acquisition decisions.\nStatement of Work:\nFire, Smoke, and Combination Fire/Smoke Damper Testing Sioux Falls VA Healthcare System\nSee the (Functional/Performance/Specification below.\nThe scope of this SOW is the procurement of a Service Agreement to provide inspection and testing of the fire, smoke, and combination fire/smoke dampers at the Sioux Falls V.A. Healthcare System, Sioux Falls South Dakota according to the terms and conditions stated herein.\nPERFORMANCE:\nThe contractor shall provide appropriate number of trips to the Sioux Falls V.A. Healthcare Systems in Sioux Falls South Dakota during the Service Agreement period to perform the inspection/testing during our business hours. See Hours of Services section below. Testing in critical areas may be required to occur during non-business hours. These activities will be coordinated with the service lines through the Contracting Officers Representative.\nContractor shall request in writing to COR a minimum of 2-weeks prior to when the activities are desired to occur, and when anticipating to move into a new area, to allow for service line coordination. Actual time given to the contractor tom complete activities will be dependent on operational requirements of the service line. Prior to the start of activities, the contractor will be required to attend a Preconstruction Risk Assessment (PCRA) and implement any protective measures deemed required by the PCRA.\nHOURS OF SERVICES:\nThe Contractor shall perform the services as specified herein Monday through Friday with the exception of National Holidays between the hours of 8:00a.m.   4:30p.m.\nGOVERNMENT NATIONAL HOLIDAYS:\nThe Contractor is not required to provide services on the following national holidays nor shall the Contractor be paid for these holidays unless previously coordinated with the COR:\n\nNew Year s Day\nJanuary 1\nMartin Luther King  s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeterans Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25\n\nWhen a holiday falls on a Sunday, the following Monday will be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by the\nU.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\nContractor Responsibilities:\nThe Contractor shall take all precautions necessary to protect against injury or damage during the performance of this contract. The Contractor shall be responsible for any injury to Contractor s employees as well as for any damage to personal or public property that occurs during the performance of this contract that is caused by contractor s employees  fault or negligence.\nContractor shall coordinate a work schedule with the VA contact. Work may be required to be performed outside of normal duty hours as required by hospital operations. Any work resulting in hours outside of 8:00am to 4:30pm CT because of operational impacts shall occur at no additional expense to the Government.\nContractor shall provide personnel on-site at the SFVAHCS to perform services under this Statement of Work within 10 calendar days of request.\nContractor shall respond within five (5) calendar days to SFVAHCS inquiries or questions and provide revised documents (if necessary).\nThe contractor shall provide all labor, resources, and travel necessary to complete the services as required within this statement of work.\nTechnicians shall provide all tools and labor necessary to perform inspections, installations, repairs, as required by this statement of work.\nSafety Requirements: The Contractor shall be responsible for providing safety measures to conduct the work. The Contractor shall comply with all VA and OSHA safety and security measure such as, the lock-out-tag program and special work permits. The contractor is also required to coordinate with the VATR or designee to gain access to the specific work area along with obtaining identification badges for all personnel prior to commencement of services.\nIt shall be understood that, throughout performance of the contract, the Contractor s personnel, while on VA property, shall adhere to all requirements and regulations that govern the VA Health Care System and its property.\nAmong all other requirements, the VA Health Care System and its property is entirely smoke- free.\nContractor and their personnel shall follow all U.S. Department of Veterans Affairs (VA) policies, standard operating procedures, applicable laws, and applicable regulations while on VA property. Violations of this may result in citation and disciplinary measures for persons violating the law.\nContractor and their personnel shall always wear visible identification while they are on premises.\nPossession of weapons is prohibited.\nContractor shall take all reasonable precautions necessary to protect persons and property from injury or damage during the performance of this contract.\nSFVAHCS Responsibilities:\nProvide AutoCAD and PDF formats of damper locations.\nProvide excel spreadsheet which will be used as a shared resource to update inventories, track findings, and everything necessary for documentation purposes for this contract.\nSFVAHCS will consider requests made by the contractor that are considered reasonable by SFVAHCS and have been presented in writing as indicated in paragraph 2.2\nCONTRACTOR PERSONNEL ACCEPTANCE: The Government reserves the right to accept or reject Contractor s staff for the rendering of services. Complaints concerning Contract Personnel s performance or conduct shall be dealt with by the Contractor, VA representative and the final decision made by the Contracting Officer.\nOverall reporting requirements\nSpreadsheet:\nContractor shall track changes in provided excel spreadsheet to aid in updating VHA records.\nDrawings:\nProvide updated drawings in AutoCAD and pdf format.\nField Verification (CLIN1)\nApplicable to Active Fire, Active Smoke, and Abandoned Fire dampers.\nConfirm access for each damper and document deficiencies. Note which access panel or inspection fitting from paragraph 9 provide access to inspect damper for inaccessible dampers.\nConfirm damper at location can be tested or witnessed from access point.\nLabel every damper on the VA provided inventory and any found that are not included in the inventory in the  Description/Location  column.\nRed background with white font. Size 12 print minimum.\nDampers above lay-in ceilings.\nCeiling grid labeled with damper number found in spreadsheet. 7.1.3.1.1.2. Damper labeled above ceiling with damper number found in\nspreadsheet.\nDampers in mechanical room areas.\nLabel by applicable access panel with damper number found in spreadsheet.\nContractor shall remove all old labels found for all dampers covered by this statement of work.\nRelocate fire alarm devices to gain access as required.\nReporting:\nUpdate details in VA provided spreadsheet where found incorrect, incomplete or in addition to existing information in the description column.\nDuct size\nWhat ductwork is serving. Supply air, exhaust air, and return air.\nDescription where to find damper.\nRoom number.\n\nDamper orientation (Vertical = perpendicular to ground and Horizontal = parallel to ground).\nEliminate duplicates.\nDocument access in the  deficiencies  column for each damper in VA provided spreadsheet. Include details for which damper access device size would provide access to observe or test damper. Contractor must note largest possible access panel that ductwork can support.\nInspection and Testing\nAbandoned Damper inspection (CLIN2)\nApplicable to abandoned Fire dampers.\nConfirm fire dampers are closed at locations identified in inventory.\nReporting:\nDocument observations in VA provided spreadsheet.\nSmoke and Fire/Smoke Damper Testing and Inspection (CLIN3)\nApplicable to Fire/Smoke dampers.\nTest as per current adopted NFPA 80 requirements\nContractor shall include personal required to operate fire alarm panel.\nContractor shall include personal required to safely operate elevators for contractor to access dampers in elevator shafts.\nReporting:\nDocument observations in VA provided spreadsheet for all eight entries for inspection of damper.\nFire damper Testing and Inspection (CLIN4)\nApplicable to active Fire dampers.\nTest as per current adopted NFPA 80 requirements.\nReporting:\nDocument observations in VA provided spreadsheet for all entries for inspection of damper.\nParts for repair (CLIN9)\nIf repairs resultant from inspections are identified, the Contractor shall provide all replacement parts needed to keep the failed component in operating condition as originally designed by the manufacturer. Parts may be repaired or replaced, as the contractor deems appropriate, so long as amount listed in CLINs for Parts Repair cited in Section B.2 (Price/Cost Schedule) are not exceeded. No used parts will be used to repair this equipment.\nFor repairs, Contractor shall furnish the VATR with a written estimate of the cost to make necessary repairs. Contractor shall also provide a comparison quote to the VATR for what that item would have cost for commercial pricing so Government has basis for making price fair and reasonableness determination, or as alternative, Contractor shall provide a quote\n\nprovided to another federal agency for similar item for determination purposes. If cost exceeds cost listed for applicable line item in Section B.2 (Price/Cost Schedule), the Contracting Officer shall consider issuing a bilateral contract modification to increase funding for this line item per coordination with VATR, that includes supporting documentation as cited above.\nAccess Panels\nSmall access panel (CLIN5)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 6/6, 8/8, or 10/10.\nSquare door with double cam.1\nMedium access panel (CLIN6)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 10/10, 12/12, or 14/14.\nSquare door with double cam.1\nLarge access panel (CLIN7)\nContractor shall provide, modify ductwork, patch and repair insulation, and install access panels ranging from 16/16, 18/18, 20/20, 22/22 or 24/24.\nSquare door with double cam.1\nAccess Panel Requirements: Ductmate industries or approved equal double cam access doors. To provide easy access into air ducts and units. This door was developed as an inexpensive alternative to the Ductmate SandwichÂ® Access Door, for low pressure applications.\nTECHNICAL INFORMATION:\nDOOR Consists of two, 24 gauge galvanized steel panels mechanically locked together\nINSULATION 1  High density fiberglass insulation with UL classification: FHC25/50 and R-value 4.2.\nGASKET Closed cell cross-linked polyethylene gasket with a service temperature range of -70Â°F to 175Â°F. The gasket is bonded to the inside of both the Dovetail and Press-On frames and also to the outside of the Dovetail frame only. Double Sided Adhesive Gasket: Closed cell cross-linked polyethylene is UL94HF1 listed with a service temperature range of -110Â°F to 158Â°F. This gasket is bonded to the outside of the Press-On frame only.\nDOVETAIL FRAME Frames measuring 6  x 6  to 12  x 12  are manufactured from 24 gauge galvanized steel. Frames measuring 14  x 14  to 24  x 24  are manufactured from 22 gauge galvanized steel. All frames are manufactured with fastened corners for increased strength and an improved Dovetail design for easy installation on Metal Duct, 1  Duct Board or 1Â½  Duct Board.\n\nPRESS-ON FRAME Frames measuring 6  x 6  to 12  x 12  are manufactured from 24 gauge galvanized steel. Frames measuring 14  x 14  to 24  x 24  are manufactured from 22 gauge galvanized steel. A durable double sided adhesive gasket allows for easy installation to metal ductwork.\nCAM & LATCH The cam is manufactured from 16 gauge galvanized steel and the latch is manufactured from 20 gauge galvanized steel. Each cam is secured to the door with a rivet. The latch is securely fastened to the frame.\nCamera Inspection Instrument Fitting (CLIN8)\nContractor shall provide, modify ductwork, patch and repair insulation, and install instrument test fittings.\nInstrument Test Fitting Requirements: Manufactured type with a minimum 50 mm (2 inch) length for insulated duct, and a minimum 25 mm (1 inch) length for duct not insulated. Test hole shall have a flat gasket for rectangular ducts and a concave gasket for round ducts at the base, and a screw cap to prevent air leakage.\nBADGES AND PARKING:\nAll Contractor personnel are required to wear identification (I.D.) badges issued by the SFVAHCS Engineering office during the entire time they are on the SFVAHCS grounds.\nIt is the responsibility of the Contractor s personnel to park in the appropriate designated parking areas. Parking information is available from the SFVAHCS security office. The SFVAHCS shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstance.\nAUTHORIZED SERVICES:\nOnly those services specified herein are authorized under this contract. Prior to performing any service of a non-contract nature, the Contracting Officer (CO) must be advised of the reasons for this additional work. Only the Contracting Officer may authorize additional services, and reimbursement will not be made unless prior authorization has been obtained.\nATTACHMENTS:\nAttachment A: Damper Location Drawings (Bldgs. 1,5 and 54)\nAttachment B: Current Damper Inventory Tracker","origin":"detail"},"contacts":[{"name":"Michael Wicht","role":"primary","email":"Michael.wicht@va.gov","phone":"4029963630","title":"Contract Specialist"}],"place_of_performance":{"zip":"57105","city":{"code":"59020","name":"Sioux Falls"},"state":{"code":"SD","name":"South Dakota"},"street":"Sioux Falls VA Health Care System","country":{"code":"USA","name":"UNITED STATES"},"street2":"2501 West 22nd Street"},"office_address":{"zip":"55101","city":"Saint Paul","state":"MN","country":"USA"},"naics_codes":["238220"],"award":{"awardee":{}},"attachments":[{"resource_id":"dd8fbf8672f24622bb0f6fdf66f3b729","name":"36C26325Q1047.docx","kind":"file","mime_type":".docx","size_bytes":32183,"posted_at":"2025-07-29T00:51:03.443Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dd8fbf8672f24622bb0f6fdf66f3b729/download","mirrored":false}],"awards":[],"related":[{"key":"36C26327R0007","latest_notice_id":"95bb4c1f961f4f338e8e9b4b060e07cc","title":"W065--V23 Home Oxygen Emergency Bridge Contract (VA-27-00021984)","solicitation_number":"36C26327R0007","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"532283","psc":"W065","set_aside":null,"state":"MN","county":"27037","county_name":"Dakota County","city":"2717288","city_name":"Eagan","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T09:15:14.204648Z"},{"key":"36C26327Q0008","latest_notice_id":"8125dedb922a4a6faede820c70a19007","title":"Minneapolis VA Medical Library Serials & Periodicals Solicitation","solicitation_number":"36C26327Q0008","notice_type":"o","first_type":"o","first_posted":"2026-08-20","last_posted":"2026-11-13","notices":8,"due_at":"2026-11-27T23:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"513120","psc":"7630","set_aside":"SBA","state":"MN","county":"27053","county_name":"Hennepin County","city":"2743000","city_name":"Minneapolis","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26326R0063","latest_notice_id":"d70c843cc4d84fd69905d2e17ce78771","title":"NWI Offsite Pathology Services","solicitation_number":"36C26326R0063","notice_type":"o","first_type":"o","first_posted":"2026-10-09","last_posted":"2026-11-20","notices":5,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"621511","psc":"Q515","set_aside":"SBA","state":"NE","county":"31055","county_name":"Douglas County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26327Q0131","latest_notice_id":"885e687dd48e45c295666a91fc27da2b","title":"6515--Medtronic FT10 Series Cauterizer","solicitation_number":"36C26327Q0131","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":"ND","county":"38017","county_name":"Cass County","city":"3825700","city_name":"Fargo","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"},{"key":"36C26327Q0124","latest_notice_id":"20b13f623c264277af31f93dde8fdcff","title":"J041--Service - AHU PM & Filter Evaluation - NWI","solicitation_number":"36C26327Q0124","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T16:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C263","office_name":"NETWORK CONTRACT OFFICE 23 (36C263)","naics":"238220","psc":"J041","set_aside":null,"state":"NE","county":"31055","county_name":"Douglas County","city":"3137000","city_name":"Omaha","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"140FF027Q0080","latest_notice_id":"c706d18cc5e846508a63090d29caa934","title":"AK-AK MARITIME NWR-LEAK REPAIR","solicitation_number":"140FF027Q0080","notice_type":"o","first_type":"o","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-26T17:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140FF0","office_name":"FWS CONTRACTING ACTIVITY","naics":"238220","psc":"J045","set_aside":"SBA","state":"AK","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"title","state_evidence":"AK-A","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open_total":57,"indexable":false}