Sources sought
Cesium Cassette -
36C26325Q0713
Department of Veterans Affairs, Network Contract Office 23. Irradiation Apparatus Manufacturing.
Response deadline
April 29, 2025 at 12:00 PM EDT
Closed 576 days ago. Posted April 23, 2025, first published April 23, 2025. Scheduled to archive May 30, 2025.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2025
2 like it are open now in irradiation apparatus manufacturing
- SEP 2026 Equipment Only Consolidation
Department of Veterans Affairs, Nac High Tech Orders
SolicitationNAICS 334517Ship to the buyer36A79727Q0002Closes in 70 daysFeb 4, 2027 - SEP 2026 Consolidation - HTME with Extended Installation Services (includes Turnkey Services)
Department of Veterans Affairs, Nac High Tech Orders
SolicitationNAICS 334517Ship to the buyer36A79727Q0001Closes in 257 daysAug 10, 2027
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334517 (irradiation apparatus manufacturing), means no more than 1,200 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of April 23, 2025. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Page 2 of 2 Cesium Cassette Panel in support of Central Iowa VA Healthcare System This is a sources sought notice only and it is not a solicitation announcement. The purpose of this sources sought notice is to gain knowledge of qualified potential contractors and their socioeconomic size classification in accordance with NAICS code 334517 Irradiation Apparatus Manufacturing, size standard 1,500 employees for small business. Responses will be used by the Government to make appropriate acquisition decisions. After a review of the responses to this sources sought notice, a solicitation announcement may be posted. A response to this sources sought notice is not an adequate reply to a potentially forthcoming solicitation. The VA Central Iowa Health Care System located in Des Moines, Iowa is seeking qualified potential contractors to provide Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panel for Central Iowa VA. Refer to the attached documents titled P09 Final Specifications Wireless 14x17 Cesium Cassette Panel for additional details and information. To respond to this sources sought notice, please complete the attached form titled Response Form to Sources Sought Notice and email the information requested to Marie Weathers, Contracting Specialist, at Michael.wicht@va.gov. The closing date and time of this sources sought notice is April 29 at 11:00 AM Central Time. This is not a solicitation and in no way obligates the Government to award any contract. Additionally, a response to this sources sought notice is not a request to be added to a prospective bidders list or to receive a copy of any forthcoming solicitation. Specification: Konica Minolta Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panel 2237 Funding/ General Equipment Name: Konica Minolta Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panel Description: The VA-CIHCS Imaging/Radiology/ Department has an immediate requirement for: two (2) Konica Minolta Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panel This is an accessory/additional cassette for existing equipment in a larger size (14X17 vs 10X12). The cassettes must be able to interface (compatible with) with PXS710 High Frequency X-ray Machine, DELL Precision T3450 XE Acquire and Konica Minolta AeroDr Battery Charger 2. Only the Konica Minolta brand is compatible with the Konica Minolta battery charger per attached email from a vendor. This will accommodate foot x-rays for Veterans with larger, swollen or casted/booted anatomy. It enables us to take 1 exposure instead of 2 (less radiation) and provide better imaging quality. Must be 20/20 Imaging HD Momentum DR panel. Salient Characteristics (at least 5), The item must: be/ have/ do these things No tethered cables (wireless) Light weight imaging detector/cassette (less than 6 lbs) Cesium Digital Radiography (DR) panel Minimum of 16 bit image detector Full charge (empty to full) less than 15 min Must be compatible with Konica Minolta AeroDr Battery Charger 2 Evaluation Criteria Technically acceptable (meets or exceeds salient characteristics of 14X17 Momentum DR Cesium Detector) Small business consideration Cost Required Individual Line Items & Quantity of Items Item # Description/Part Number* Qty 1 14X17 DR Panel 2 (1 each) Cleaning Instructions for all equipment, supplies and accessories. 3-year warranty Optional Line Items Trade-In Items (include make, model and serial # of all items to be used as a trade-in) no trade in for this requirement. Product Specifications (CD, PDF or Word) available on Hospital Grade Wireless Digital DR Panel for Digital X-Ray 10x12 & 14x17, Cassette Sized true Flatpanel (2020imaging.net) Discount for Volume Purchase Not available for this purchase Expendable Supplies There are no expendable supplies for this equipment Maintenance and Full-Service Repair Contracts After 1 year Warranty Information - 3-year warranty (parts and labor) included in cost. In Service Training Training not required. Bio-Med Training Bio-med staff training not required. Installation and/or De-Installation Services (does this equipment require special electrical, gas, steam, oxygen, or network connectivity?) This equipment has no special install/de-install
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- 36C26325Q0713.docx30 KB, April 23, 2025
- Response Form to Sources Sought Notice 1.pdf150 KB, April 23, 2025
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 23, 2025
Sources sought
Due April 29, 2025 at 12:00 PM EDT. SAM.gov, notice 043517e9b9f949cdafb76c8849abe56c
3 revisions on SAM
- April 23, 2025: publish, sources sought
- April 23, 2025: publish, sources sought
- April 23, 2025: publish, sources sought
April 23, 2025
Sources sought
Due April 30, 2025 at 12:00 PM EDT. SAM.gov, notice 0b1e0c8ea0954c88a555b3815aac9914
3 revisions on SAM
- April 23, 2025: publish, sources sought
- April 23, 2025: publish, sources sought
- April 23, 2025: publish, sources sought
April 23, 2025
Sources sought
Due April 29, 2025 at 12:00 PM EDT. SAM.gov, notice 407f7dc460374e0b81cf34a89632a4d1
3 revisions on SAM
- April 23, 2025: publish, sources sought
- April 23, 2025: publish, sources sought
- April 23, 2025: publish, sources sought
Points of contact
- Michael Wicht, Contract Specialistmichael.wicht@va.gov4029963630