Award notice
Illumina Maintenance
36C26325Q0051
Department of Veterans Affairs, Network Contract Office 23. Electronic and Precision Equipment Repair and Maintenance.
Awarded
$44,352.28 on the award notice, October 24, 2024, contract 36C26325P0059
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one was awarded in 2024
63 like it are open now in electronic and precision equipment repair and maintenance
- 124PSA27Q0045 - Sources Sought for Autoclave and Washer Bi-Annual Maintenance Services Ames IA
Usda, Departmental Administration, Ocp Service and Supply Div
Sources soughtSmall businessNAICS 811210Ames, IA124PSA27Q0045Due in 5 daysDec 1 - Preventive Maintenance Service - GE TracerLab
National Institutes of Health, National Institutes of Health Olao
Combined synopsis and solicitationNAICS 811210Location not published75N98027Q00080Due tomorrowNov 27 - ALCON CONSTELLATION LXT AND EMBEDDED LASERS & ALCON CENTURION VISION PHACOEMULSIFICATION PMI SVCS
Department of Veterans Affairs, 262-Network Contract Office 22
Combined synopsis and solicitationSDVOSBNAICS 811210Long Beach, CA36C26227Q0063Due tomorrowNov 27
All 63 open in electronic and precision equipment repair and maintenance
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Award notice. Who won, when, and for how much. Glossary
- How it ended
- Awarded to Illumina, Inc. on October 24, 2024. The contracting office reported 1 offer (not competed).
Description
As published on SAM.gov.
Statement of Work Requirement for existing equipment Illumina NEXTSeq 2000 located at The State Hygienic Lab, 2490 Crosspark Rd, Coralville, IA 52241. The period of performance shall be 11/11/24 11/10/25 with two options periods.
Option Year 1:
11/11/25 11/10/26 Option Year 2: 11/11/26 11/10/27 The support includes the following:
The Contractor shall provide reagent replacement upon instrument failures, one annual Preventative Maintenance and 18 hour a day 5 days a week remote technician support. The Contractor shall provide emergency on-site repair services with a 48-hour response time. The Contractor shall provide documentation (e.g., service report) detailing all repair services performed upon completion of services. The Contractor shall respond within 48-hours (Monday through Friday).
Prior to reporting to a service call, the contract s services representation shall notify the COR (Contracting Officers Representative) via email or telephonically before commencing services during normal duty operating hours (0800 to 1630 CST). During other than normal operating hours, the Contractor's representative shall arrange for access with the COR. The Government and the Contractor's service representative will exchange hazard communication information before the commencement of any repair.
When required, the Contractor's service representative will comply with the Occupational Safety and Health Administration (OSHA) lockout/tag-out standards while performing maintenance on Medical Devices/Medical Device Systems (MD/MDS). Upon completion of services by the Contractor's service representative, a service report shall be provided to the COR. The service report shall provide detailed information regarding the cause of the MD/MDS malfunction and corrective action taken.
It shall include, at a minimum, the time required to complete the work and a list of parts replaced with part numbers prior to leaving the facility. In the event all information is not available to the Contractor's service representative when services are performed, the initial service report shall include all available information to close work order within five days. The Contractor shall provide the balance of the required information to the COR no later than ten days after services are completed.
The Contractor shall have access to all necessary diagnostic software (if applicable). The Contractor shall use only Original Equipment Manufacturer (OEM) new or OEM refurbished repair parts. The Contractor's service representative will be factory trained and have desired to have a minimum of two years of experience working on the contracted MD/MDS The Contractor shall furnish all software updates/patches issued by the MD/MDS manufacturer.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Illumina, Inc.
- UEI
- KMW3CRWNAAF3
- CAGE
- 1WCS2
- Vendor location
- San Diego, CA
- Contract
- 36C26325P0059, purchase order
- Obligated
- $90,921.28, potential $137,768
- Actions
- 3 between October 24, 2024 and June 24, 2026
- Competition
- Not Competed, 1 offer received
- Set-aside reported
- No Set Aside Used.
- Described as
- Maintenance Services for Illumina Nextseq 2000 for the Iowa City VA Health Care System
- Match
- award number 36C26325P0059 equals the contract number; same awarding office 36C263 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
October 24, 2024
Award notice
Awarded to Illumina, Inc. San Diego 92122 for $44,352. SAM.gov, notice e5446a25802840b782e1b147b75fed87
Points of contact
- Amanda Patterson-Elliott, Contract Specialistamanda.patterson-Elliott-elliott@va.gov319-338-0581 x636290