{"canonical":"https://sealedbidder.com/opportunities/36c26227q0022","key":"36C26227Q0022","url":"https://sealedbidder.com/opportunities/36c26227q0022","title":"H365--ANNUAL MEDICAL GAS TESTING POP: 12/01/2026 - 09/30/2031","solicitation_number":"36C26227Q0022","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-11-12T18:00:00Z","first_posted":"2026-09-23","last_posted":"2026-11-06","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541380","psc":"H365","set_aside":"SDVOSBC","place_state":"CA","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"06071","place_county_name":"San Bernardino County","place_city":"0642370","place_city_name":"Loma Linda","winner":null,"award_amount":null,"publications":[{"notice_id":"f2dd10e4902448de9bbde5be77c31a07","title":"J065--ANNUAL MEDICAL GAS TESTING Loma Linda VA POP: 12/01/2026 - 11/30/2031","solicitation_number":"36C26227Q0022","notice_type":"r","base_type":"r","posted":"2026-09-23","posted_at":"2026-09-24T00:40:49.832Z","due_at":"2026-09-30T17:00:00Z","due_date":"2026-09-30","cancelled":false,"archived":false,"archive_date":"2026-11-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f2dd10e4902448de9bbde5be77c31a07/view","enriched":true,"history":[{"index":1,"title":"J065--ANNUAL MEDICAL GAS TESTING Loma Linda VA POP: 12/01/2026 - 11/30/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-24T00:40:49.832Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f2dd10e4902448de9bbde5be77c31a07","solicitation_number":"36C26227Q0022"}]},{"notice_id":"74391079a7f54655986d2066b40ef3f9","title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","solicitation_number":"36C26227Q0022","notice_type":"k","base_type":"r","posted":"2026-10-30","posted_at":"2026-10-30T20:48:13.709Z","due_at":"2026-11-09T18:00:00Z","due_date":"2026-11-09","cancelled":false,"archived":false,"archive_date":"2027-01-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/74391079a7f54655986d2066b40ef3f9/view","enriched":true,"history":[{"index":2,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T20:48:13.709Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"74391079a7f54655986d2066b40ef3f9","solicitation_number":"36C26227Q0022","related_opportunity_id":"f2dd10e4902448de9bbde5be77c31a07"},{"index":1,"title":"J065--ANNUAL MEDICAL GAS TESTING Loma Linda VA POP: 12/01/2026 - 11/30/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-24T00:40:49.832Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f2dd10e4902448de9bbde5be77c31a07","solicitation_number":"36C26227Q0022"}]},{"notice_id":"1c061ac1bdf148e19982bb5f68914c1c","title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","solicitation_number":"36C26227Q0022","notice_type":"k","base_type":"k","posted":"2026-11-02","posted_at":"2026-11-02T18:46:35.906Z","due_at":"2026-11-09T18:00:00Z","due_date":"2026-11-09","cancelled":false,"archived":false,"archive_date":"2027-01-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1c061ac1bdf148e19982bb5f68914c1c/view","enriched":true,"history":[{"index":2,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T18:46:35.906Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1c061ac1bdf148e19982bb5f68914c1c","solicitation_number":"36C26227Q0022","parent_opportunity_id":"74391079a7f54655986d2066b40ef3f9"},{"index":1,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T20:48:13.709Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"74391079a7f54655986d2066b40ef3f9","solicitation_number":"36C26227Q0022","related_opportunity_id":"f2dd10e4902448de9bbde5be77c31a07"}]},{"notice_id":"cf4147a2278a475fbce5c140a7b7165e","title":"H365--ANNUAL MEDICAL GAS TESTING POP: 12/01/2026 - 09/30/2031","solicitation_number":"36C26227Q0022","notice_type":"k","base_type":"k","posted":"2026-11-06","posted_at":"2026-11-06T20:50:56.783Z","due_at":"2026-11-12T18:00:00Z","due_date":"2026-11-12","cancelled":false,"archived":false,"archive_date":"2027-01-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cf4147a2278a475fbce5c140a7b7165e/view","enriched":true,"history":[{"index":3,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 12/01/2026 - 09/30/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T20:50:56.783Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf4147a2278a475fbce5c140a7b7165e","solicitation_number":"36C26227Q0022","parent_opportunity_id":"74391079a7f54655986d2066b40ef3f9"},{"index":2,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T18:46:35.906Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1c061ac1bdf148e19982bb5f68914c1c","solicitation_number":"36C26227Q0022","parent_opportunity_id":"74391079a7f54655986d2066b40ef3f9"},{"index":1,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T20:48:13.709Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"74391079a7f54655986d2066b40ef3f9","solicitation_number":"36C26227Q0022","related_opportunity_id":"f2dd10e4902448de9bbde5be77c31a07"}]}],"latest_notice_id":"cf4147a2278a475fbce5c140a7b7165e","first_type":"r","notices":[{"dates":{"posted":"2026-09-23","posted_at":"2026-09-24T00:40:49.832Z","created_at":"2026-09-24T00:40:47.604Z","modified_at":"2026-09-24T00:40:49.832Z","response_deadline":{"raw":"2026-09-30T10:00:00-07:00","utc":"2026-09-30T17:00:00Z","date":"2026-09-30","time":"10:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f2dd10e4902448de9bbde5be77c31a07/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J065--ANNUAL MEDICAL GAS TESTING Loma Linda VA POP: 12/01/2026 - 11/30/2031","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-29","archive_type":"auto_custom"},"history":[{"index":1,"title":"J065--ANNUAL MEDICAL GAS TESTING Loma Linda VA POP: 12/01/2026 - 11/30/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-24T00:40:49.832Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f2dd10e4902448de9bbde5be77c31a07","solicitation_number":"36C26227Q0022"}],"contacts":[{"name":"Catherine Fernandez","role":"primary","email":"catherine.fernandezpedernera@va.gov","phone":"(480)-466-7937","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"f2dd10e4902448de9bbde5be77c31a07","lineage_id":"f2dd10e4902448de9bbde5be77c31a07","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T05:09:40.355064487Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"6d316c08a421839e24c2dd5248ee0690255718296333fbbaf3c5f3b8d987c69a","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-09-24T04:21:46.782462570Z"},"description":{"html":"This is a SOURCES SOUGHT ANNOUNCEMENT ONLY.  It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract.  Requests for a solicitation will not receive a response.  Responses to this-- sources sought announcement must be in writing.  The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below.  Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition.  Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) Unique Entity ID (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below.\n \nThe Loma Linda VA Health Care System (LLVAHCS) located at 11201 Benton St. Loma Linda, CA 92357 is seeking a potential qualified contractor that can provide: Medical Gas Inspection. \nImportant information: The Government is not obligated to/nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request.  This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach.  The Government will in no way be bound to this information if any solicitation is issued.  The VA is mandated by Public Law 109-461 to consider a total set-aside for Service-Disabled Veteran Owned Small Business set aside. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined.  No sub-contracting opportunity is anticipated.  The North American Classification System (NAICS) code for this acquisition is 811310   Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance   $12.5 Million.\n\n*******DRAFT*******DRAFT******DRAFT*******DRAFT*******\n\nD.1  STATEMENT OF WORK \n\nTITLE:\n                   VA Loma Linda Healthcare System s (VALLHCS) Annual Med Gas Inspection\nBACKGROUND INFORMATION:\nVA Loma Linda Healthcare System s (VALLHCS) requires a new maintenance and inspection contract for Medical Gas Distribution System. The Medical gas distribution system must undergo routine source and pipeline system inspections and maintenance to ensure continuous patient safety.\nPARTS and EQUIPMENT LIST:\n\nPARTS\nQUANTITY\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nOBJECTIVES:\nVA Loma Linda Healthcare System s (VALLHCS) Medical gas distribution system inspections shall comply with NFPA99 (Health Care Facilities Code), OSHA Life safety fire code, and the ASSE 6000 standard. They require annual central supply checks, routine alarm tests, and specialized third-party inspections by certified ASSE 6020 Inspectors. \nThe services performed shall conform to industry standards and this statement of work (SOW) and lockout and tagout procedures are to be done according to (OSHA Standard29 CFR 1910.147) VA Loma Linda Healthcare systems Policies and Regulations.\n\nSCOPE:\nContractors shall provide all labor, personnel, supplies, equipment, tools, materials, supervision and other necessary items. Inspection, testing and verification are mandatory for medical gas work and will be performed by licensed ASSE 6020 Medical Gas Inspectors and ASSE 6030 Medical Gas Verifiers.\nContractor shall perform Annual Medical Gas Distribution System Inspection on all Sources, Alarms, Zone Valves, and Patient Terminal Outlets / Inlets and bulk oxygen system.\nIncluding Areas as follows: \nMain Hospital\nFirst Floor:\nCLC, CLC Palliative Care, CLC Rehab, 1SW, Mod 3, Emergency department, \nSecond Floor: \nICU: 2SW, 2SE, \nThird Floor: \nOR 1 through 8, 3F-14, 3F-16, 3D-72, Recovery Room, SICU, X-Ray, MRI, Short Stay, G.I. Labs, 3NW, 3NE, 3SW, 3SE\nFourth Floor: 4NW, 4NE, 4SW, 4SE, Nuclear Med, Dialysis, Blood Laboratory, \n\n Oncology Building 31\n Eye Clinic Building 32\n Audiology Building 30\n  List of items provided for inspection:\nMedical Gas Sources \nMedical air compressors, vacuum pumps, gas manifolds, and any other device used to deliver medical gases to patients.\n1.Inventoried by location.\n2.Leak checked and documented.\n3.Recommendations to comply with NFPA 99, 2024 edition Health Care Facilities Code.\nMaster Alarm Panels \nAlarm panels are located at two separate locations throughout the facility. These panels monitor conditions directly from the medical gas sources.\n1.Inventoried by location\n2.Tested by removing existing pressure switches and other sensing devices to test the actuation points. No interruption of service is necessary if each device is mounted on code compliant demand fittings.\n3.Verify proper points are being monitored at each panel.\n4.Verify each panel is in the proper location.\n5.Verify proper labeling.\nArea Alarm Panels \nAlarm panels that are located throughout the facility monitor medical gas pressures for the area only.\n1.Inventoried by location.\n2.Tested by lowering pressure in each zone for each gas and documenting the alarm point.\n3.Verify proper location.\n4.Verify proper labeling.\nZone Valve Boxes \nAccessible valves typically found in a corridor covered by a plastic window used mostly for emergency purposes.\n1.Inventoried by location.\n2.Checked for leakage from packing, flange, and gauge port using oxygen safe leak detector.\n3.Verify proper labeling.\n4.Verify proper locations.\nMedical Gas Outlets/Inlets \nConnection points for each gas are located mostly in-patient areas.\n1.Inventoried by location in each room or area inspected left to right and then top to bottom.\n2.Complete an operational pressure test on each outlet and document pass/fail. (Test Parameters per NFPA 99, 2024 edition)\n3.Check function of outlet/inlet and latching mechanism.\n4.Check for leakage with equipment and without equipment attached.\n5.Document connection type and outlet/inlet manufacturer. \nOxygen Particulate Analysis \nParticulates are often found in existing medical gas systems due to improper installation methods that were used in the past.\n1.Samples are taken on each floor in each building.  \nMedical Air Dewpoint Analysis \nMoisture is removed from medical air systems at the source. Periodic Analysis of moisture throughout the facility is important to prevent possible contamination.\n1.Samples are taken on each floor in each building.  \n2.A sample will be taken at the medical air source to compare building samples.\nEmergency Oxygen Supply Connection Box \nThis box is typically mounted on the outside of a facility to facilitate the back feeding of the oxygen system if there is an interruption in service.\n1.Inventoried by location.\n2.Check existing location for proper compliance.\n3.Check existing piping arrangements to ensure proper order of components.\n4.Check to make sure box is secured.\nTesting to ensure all medical gas booms, and columns are leak free \nMost operating rooms and procedure rooms have some sort of device to help clinical personnel use the medical gases in the middle of the room by the patient. These devices are either medical gas booms or columns. The hoses and threaded connections inside these devices need to be checked periodically to ensure that there are no leaks.\n1. All hoses and secondary equipment were removed from the outlets on each boom and column.\n2. A test pressure for each system was observed and documented.\n3. All medical gas valves were shut over a period of 10 minutes.\n4. After the test period of 10 minutes passed the pressure was observed once again.\n5. Any pressure drop was recorded.\n6. Recommendations will be made to find existing leaks and to make repairs.\nFacilities responsibility:\nA.  The facility shall coordinate with all departments to notify of the medical gas/vacuum system inspection and or repairs to be completed.\nB. The facility shall supply Inspecting personnel with facility maintenance personnel to unlock secured areas that have medical gas/vacuum systems, or a master key may also be supplied to complete inspection services.\n\nREPORTS:\n\nThe contractor will annotate compliance with ASSE 6000, 6020 and 6030 Medical Gas specifications and requirements by submitting a detailed PM report to the Contracting Officer s Representative (COR) along with pictures for each equipment, after PM is completed. The reports shall be submitted to COR, within 14 days of work completion. The contractor shall provide additional reports as required by the COR.  \nThe contractor s report shall show the information listed below. The report shall contain, at a minimum, any other information required by the COR and all applicable NFPA and Joint Commission and OSHA specifications, the following:\nDate of P.M.\nTime of P.M.\nIdentification of the equipment descriptions, manufacturer, and serial number\nLocation of equipment under P.M. or repair\nProbable cause of repairs\nCorrection action (servicing, repair or replacement) \nWho was notified?\nComments and recommendations.\nCompletion date\nContractor shall complete scheduled preventive maintenance service, inspection and repairs to NFPA and Joint Commission and OSHA requirements for the Medical Gas Distribution System.\nOVER AND ABOVE REPAIR:\n\nUpon discovery of over and above repairs or unforeseen requirements, Contractor shall\nimmediately notify the POC. Parts shall not be procured, nor installation or repairs initiated until approval is obtained from the Contracting Officer and appropriate Facilities Staff/POC. Charges for repair, labor and parts shall originate only when required and upon prior approval being granted by the Contracting Officer. Any additional work performed must be by licensed ASSE 6010 Medical Gas System Installers and ASSE 6040 Medical Gas System Maintenance Personnel.\n\nPERIOD OF PERFORMANCE:\n\nBase Plus Four from performance start date.  Work may be scheduled during the day or night (Depending on load demand), Monday thru Friday and/or Saturday thru Sunday.\nDaytime hours: 6 am to 4 pm \nEvening hours: 4 pm to 4 am \nContractor shall initiate work within 2 weeks of being contacted by the designated Contracting Officer s Point of Contact (POC) or designee. Work shall be scheduled through the POC or designee, who will coordinate with VALLHCS staff. Timelines are subject to change due to VALLHCS operational requirements.  \n\nPLACE OF PERFORMANCE:\n\n        VA Loma Linda 11201 Benton St. Loma Linda, CA   92357\n\nLICENSING REQUIREMENTS:\n\nOfferor must possess a 30-hour Occupational Safety and Health Administration (OSHA) safety card.\nASSE Medical Gas Verifier 6030\nASSE Medical Gas inspector 6020\n\nSPECIFIC REQUIREMENTS:\nContractor shall schedule start date with POC or designee five (5) business days in advance.\nContactor personnel shall have valid Loma Linda PIV badges before starting work.\nContractor shall coordinate energy source LOCK OUT /TAG OUT procedures with VALLHCS Electrical Supervisor before starting work. When work is complete, Contractor shall notify the VALLHCS Electrical Supervisor that energy sources will be restored and require verification.\nContractor s supervisor or lead technician are to check in with VALLHCS Electrical Supervisor, or in their absence, with Graphics Control prior to work each day.\nContractor shall conform to the following standards, policies, regulations, governing agency, and any other local, state, or Federal guidelines that are not listed here.\nOSHA 29CFR Regulations, www.osha.gov \nNFPA 99, www.nfpa.org\nChapter 5 Gas and Vacuum Systems\n5.1 Category 1 Piped Gas and Vacuum Systems\n5.2 Category 2 Piped Gas and Vacuum Systems\n5.3 Category 3 Piped Gas and Vacuum Systems\nASSE\n\nAUTHORIZED SERVICES:\n\nOnly those services specified herein are authorized under this contract. Before permitting and/or performing any service of a non-contract nature, the Contractor shall advise the CO of the reason (s) for the additional work and/or service. The Contractor is cautioned that only the CO or his/her designee may authorize additional service that are within the scope of this contract and that reimbursement shall not be made unless prior authorization is obtained from the CO. All changes to the contract shall be issued through a contract modification in writing from the CO to the Contractor.\n\nDELEGATION OF AUTHORITY:\n\nNo additional service shall be provided without the approval from the Contracting Officer (CO) or his/her designee of this contract. The Contractor shall not accept any instructions issued by any other person(s) other than the CO or his/her delegated representative acting within the limits of his/her authority.\n\nGOVERNMENT-FURNISHED EQUIPMENT (GFE) GOVERNMENT FURNISHED INFORMATION (GFI):\n\n       No Government equipment will be used by the Vendor.\n\nRECOGNIZED HOLIDAYS:\n\nThe following is a list of all Government recognized holidays:\n\nIn accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following National holidays  are observed and for the purpose of this contract are defined as  Legal Federal official holidays :\n\n\nNew Year s Day: January 1\nMartin Luther King  s Birthday: Third Monday in January\nPresident s Day: Third Monday in February\nMemorial Day: Last Monday in May\nJuneteenth Independence Day: June 19\nIndependence Day: July 4\nLabor Day: First Monday in September\nColumbus Day: Second Monday in October\nVeterans Day: November 11\nThanksgiving Day: Fourth Thursday in November\nChristmas Day: December 25\n\n     If a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When    a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nCONTRACTOR EMPLOYEES AND BADGES:\n\n    Contractor personnel shall present a neat appearance and be easily recognized as Contractor    employees. Examples: wearing of distinctive clothing such as uniform, badges, patches, etc.\nAll contractor personnel shall be required to wear VA provided identification (I.D.) badges above the waist at all times while on the VA grounds. Contractor shall be required to coordinate with the COR to obtain the VA provided I.D. badges for all staff. All VA provided I.D. badges shall be returned at the end of the contract or upon completion of service. Failure to wear ID badges may result in removal from any of the VA facilities and/or otherwise referred to Government property.\n\n\nSAFETY AND PPE EQUIPMENT:\n\n  Personal Protective Equipment shall be provided for each Contractor employee by the    Contractor. Possession of weapons are prohibited.  \n\nSMOKING and VAPING POLICIES:\n\n      Smoking and vaping are prohibited on Government property.\n\nPARKING:\n\nIt is the responsibility of Contractor personnel to park only in designated parking areas. Parking information is    available from the VA Security Service. The VA shall not invalidate or make reimbursement for parking violations of the Contractor's personnel under any circumstances.     \n\nCOMPLAINTS:\n\nContractor shall promptly and courteously respond to complaints within three (3) working days to the COR. Including complaints brought to the contractor s attention by the CO. Contractor shall maintain a written record of all complaints, both written and oral showing the identity of the individual, the nature of the complaint, and contractor s response. Contractor shall permit the Government to inspect the written records of complaints upon reasonable notice from the CO.\n\nNotice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be certified by the Small Business Administration; Veteran Small Business Certification, (VetCert) https://veterans.certify.sba.gov/.     All interested Offerors should submit information by e-mail to: catherine.fernandezpedernera@va.gov . \n\nAll information submissions to be marked Attn: Catherine Fernandez, Contract Specialist and should be received no later than 10:00 AM PST on September 30, 2026.","text":"This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this-- sources sought announcement must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) Unique Entity ID (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below.\n\nThe Loma Linda VA Health Care System (LLVAHCS) located at 11201 Benton St. Loma Linda, CA 92357 is seeking a potential qualified contractor that can provide: Medical Gas Inspection.\nImportant information: The Government is not obligated to/nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service-Disabled Veteran Owned Small Business set aside. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance $12.5 Million.\n\n*******DRAFT*******DRAFT******DRAFT*******DRAFT*******\n\nD.1 STATEMENT OF WORK\n\nTITLE:\nVA Loma Linda Healthcare System s (VALLHCS) Annual Med Gas Inspection\nBACKGROUND INFORMATION:\nVA Loma Linda Healthcare System s (VALLHCS) requires a new maintenance and inspection contract for Medical Gas Distribution System. The Medical gas distribution system must undergo routine source and pipeline system inspections and maintenance to ensure continuous patient safety.\nPARTS and EQUIPMENT LIST:\n\nPARTS\nQUANTITY\n\nOBJECTIVES:\nVA Loma Linda Healthcare System s (VALLHCS) Medical gas distribution system inspections shall comply with NFPA99 (Health Care Facilities Code), OSHA Life safety fire code, and the ASSE 6000 standard. They require annual central supply checks, routine alarm tests, and specialized third-party inspections by certified ASSE 6020 Inspectors.\nThe services performed shall conform to industry standards and this statement of work (SOW) and lockout and tagout procedures are to be done according to (OSHA Standard29 CFR 1910.147) VA Loma Linda Healthcare systems Policies and Regulations.\n\nSCOPE:\nContractors shall provide all labor, personnel, supplies, equipment, tools, materials, supervision and other necessary items. Inspection, testing and verification are mandatory for medical gas work and will be performed by licensed ASSE 6020 Medical Gas Inspectors and ASSE 6030 Medical Gas Verifiers.\nContractor shall perform Annual Medical Gas Distribution System Inspection on all Sources, Alarms, Zone Valves, and Patient Terminal Outlets / Inlets and bulk oxygen system.\nIncluding Areas as follows:\nMain Hospital\nFirst Floor:\nCLC, CLC Palliative Care, CLC Rehab, 1SW, Mod 3, Emergency department,\nSecond Floor:\nICU: 2SW, 2SE,\nThird Floor:\nOR 1 through 8, 3F-14, 3F-16, 3D-72, Recovery Room, SICU, X-Ray, MRI, Short Stay, G.I. Labs, 3NW, 3NE, 3SW, 3SE\nFourth Floor: 4NW, 4NE, 4SW, 4SE, Nuclear Med, Dialysis, Blood Laboratory,\n\nOncology Building 31\nEye Clinic Building 32\nAudiology Building 30\nList of items provided for inspection:\nMedical Gas Sources\nMedical air compressors, vacuum pumps, gas manifolds, and any other device used to deliver medical gases to patients.\n1.Inventoried by location.\n2.Leak checked and documented.\n3.Recommendations to comply with NFPA 99, 2024 edition Health Care Facilities Code.\nMaster Alarm Panels\nAlarm panels are located at two separate locations throughout the facility. These panels monitor conditions directly from the medical gas sources.\n1.Inventoried by location\n2.Tested by removing existing pressure switches and other sensing devices to test the actuation points. No interruption of service is necessary if each device is mounted on code compliant demand fittings.\n3.Verify proper points are being monitored at each panel.\n4.Verify each panel is in the proper location.\n5.Verify proper labeling.\nArea Alarm Panels\nAlarm panels that are located throughout the facility monitor medical gas pressures for the area only.\n1.Inventoried by location.\n2.Tested by lowering pressure in each zone for each gas and documenting the alarm point.\n3.Verify proper location.\n4.Verify proper labeling.\nZone Valve Boxes\nAccessible valves typically found in a corridor covered by a plastic window used mostly for emergency purposes.\n1.Inventoried by location.\n2.Checked for leakage from packing, flange, and gauge port using oxygen safe leak detector.\n3.Verify proper labeling.\n4.Verify proper locations.\nMedical Gas Outlets/Inlets\nConnection points for each gas are located mostly in-patient areas.\n1.Inventoried by location in each room or area inspected left to right and then top to bottom.\n2.Complete an operational pressure test on each outlet and document pass/fail. (Test Parameters per NFPA 99, 2024 edition)\n3.Check function of outlet/inlet and latching mechanism.\n4.Check for leakage with equipment and without equipment attached.\n5.Document connection type and outlet/inlet manufacturer.\nOxygen Particulate Analysis\nParticulates are often found in existing medical gas systems due to improper installation methods that were used in the past.\n1.Samples are taken on each floor in each building.\nMedical Air Dewpoint Analysis\nMoisture is removed from medical air systems at the source. Periodic Analysis of moisture throughout the facility is important to prevent possible contamination.\n1.Samples are taken on each floor in each building.\n2.A sample will be taken at the medical air source to compare building samples.\nEmergency Oxygen Supply Connection Box\nThis box is typically mounted on the outside of a facility to facilitate the back feeding of the oxygen system if there is an interruption in service.\n1.Inventoried by location.\n2.Check existing location for proper compliance.\n3.Check existing piping arrangements to ensure proper order of components.\n4.Check to make sure box is secured.\nTesting to ensure all medical gas booms, and columns are leak free\nMost operating rooms and procedure rooms have some sort of device to help clinical personnel use the medical gases in the middle of the room by the patient. These devices are either medical gas booms or columns. The hoses and threaded connections inside these devices need to be checked periodically to ensure that there are no leaks.\n1. All hoses and secondary equipment were removed from the outlets on each boom and column.\n2. A test pressure for each system was observed and documented.\n3. All medical gas valves were shut over a period of 10 minutes.\n4. After the test period of 10 minutes passed the pressure was observed once again.\n5. Any pressure drop was recorded.\n6. Recommendations will be made to find existing leaks and to make repairs.\nFacilities responsibility:\nA. The facility shall coordinate with all departments to notify of the medical gas/vacuum system inspection and or repairs to be completed.\nB. The facility shall supply Inspecting personnel with facility maintenance personnel to unlock secured areas that have medical gas/vacuum systems, or a master key may also be supplied to complete inspection services.\n\nREPORTS:\n\nThe contractor will annotate compliance with ASSE 6000, 6020 and 6030 Medical Gas specifications and requirements by submitting a detailed PM report to the Contracting Officer s Representative (COR) along with pictures for each equipment, after PM is completed. The reports shall be submitted to COR, within 14 days of work completion. The contractor shall provide additional reports as required by the COR.\nThe contractor s report shall show the information listed below. The report shall contain, at a minimum, any other information required by the COR and all applicable NFPA and Joint Commission and OSHA specifications, the following:\nDate of P.M.\nTime of P.M.\nIdentification of the equipment descriptions, manufacturer, and serial number\nLocation of equipment under P.M. or repair\nProbable cause of repairs\nCorrection action (servicing, repair or replacement)\nWho was notified?\nComments and recommendations.\nCompletion date\nContractor shall complete scheduled preventive maintenance service, inspection and repairs to NFPA and Joint Commission and OSHA requirements for the Medical Gas Distribution System.\nOVER AND ABOVE REPAIR:\n\nUpon discovery of over and above repairs or unforeseen requirements, Contractor shall\nimmediately notify the POC. Parts shall not be procured, nor installation or repairs initiated until approval is obtained from the Contracting Officer and appropriate Facilities Staff/POC. Charges for repair, labor and parts shall originate only when required and upon prior approval being granted by the Contracting Officer. Any additional work performed must be by licensed ASSE 6010 Medical Gas System Installers and ASSE 6040 Medical Gas System Maintenance Personnel.\n\nPERIOD OF PERFORMANCE:\n\nBase Plus Four from performance start date. Work may be scheduled during the day or night (Depending on load demand), Monday thru Friday and/or Saturday thru Sunday.\nDaytime hours: 6 am to 4 pm\nEvening hours: 4 pm to 4 am\nContractor shall initiate work within 2 weeks of being contacted by the designated Contracting Officer s Point of Contact (POC) or designee. Work shall be scheduled through the POC or designee, who will coordinate with VALLHCS staff. Timelines are subject to change due to VALLHCS operational requirements.\n\nPLACE OF PERFORMANCE:\n\nVA Loma Linda 11201 Benton St. Loma Linda, CA 92357\n\nLICENSING REQUIREMENTS:\n\nOfferor must possess a 30-hour Occupational Safety and Health Administration (OSHA) safety card.\nASSE Medical Gas Verifier 6030\nASSE Medical Gas inspector 6020\n\nSPECIFIC REQUIREMENTS:\nContractor shall schedule start date with POC or designee five (5) business days in advance.\nContactor personnel shall have valid Loma Linda PIV badges before starting work.\nContractor shall coordinate energy source LOCK OUT /TAG OUT procedures with VALLHCS Electrical Supervisor before starting work. When work is complete, Contractor shall notify the VALLHCS Electrical Supervisor that energy sources will be restored and require verification.\nContractor s supervisor or lead technician are to check in with VALLHCS Electrical Supervisor, or in their absence, with Graphics Control prior to work each day.\nContractor shall conform to the following standards, policies, regulations, governing agency, and any other local, state, or Federal guidelines that are not listed here.\nOSHA 29CFR Regulations, www.osha.gov\nNFPA 99, www.nfpa.org\nChapter 5 Gas and Vacuum Systems\n5.1 Category 1 Piped Gas and Vacuum Systems\n5.2 Category 2 Piped Gas and Vacuum Systems\n5.3 Category 3 Piped Gas and Vacuum Systems\nASSE\n\nAUTHORIZED SERVICES:\n\nOnly those services specified herein are authorized under this contract. Before permitting and/or performing any service of a non-contract nature, the Contractor shall advise the CO of the reason (s) for the additional work and/or service. The Contractor is cautioned that only the CO or his/her designee may authorize additional service that are within the scope of this contract and that reimbursement shall not be made unless prior authorization is obtained from the CO. All changes to the contract shall be issued through a contract modification in writing from the CO to the Contractor.\n\nDELEGATION OF AUTHORITY:\n\nNo additional service shall be provided without the approval from the Contracting Officer (CO) or his/her designee of this contract. The Contractor shall not accept any instructions issued by any other person(s) other than the CO or his/her delegated representative acting within the limits of his/her authority.\n\nGOVERNMENT-FURNISHED EQUIPMENT (GFE) GOVERNMENT FURNISHED INFORMATION (GFI):\n\nNo Government equipment will be used by the Vendor.\n\nRECOGNIZED HOLIDAYS:\n\nThe following is a list of all Government recognized holidays:\n\nIn accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following National holidays are observed and for the purpose of this contract are defined as Legal Federal official holidays :\n\nNew Year s Day: January 1\nMartin Luther King s Birthday: Third Monday in January\nPresident s Day: Third Monday in February\nMemorial Day: Last Monday in May\nJuneteenth Independence Day: June 19\nIndependence Day: July 4\nLabor Day: First Monday in September\nColumbus Day: Second Monday in October\nVeterans Day: November 11\nThanksgiving Day: Fourth Thursday in November\nChristmas Day: December 25\n\nIf a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nCONTRACTOR EMPLOYEES AND BADGES:\n\nContractor personnel shall present a neat appearance and be easily recognized as Contractor employees. Examples: wearing of distinctive clothing such as uniform, badges, patches, etc.\nAll contractor personnel shall be required to wear VA provided identification (I.D.) badges above the waist at all times while on the VA grounds. Contractor shall be required to coordinate with the COR to obtain the VA provided I.D. badges for all staff. All VA provided I.D. badges shall be returned at the end of the contract or upon completion of service. Failure to wear ID badges may result in removal from any of the VA facilities and/or otherwise referred to Government property.\n\nSAFETY AND PPE EQUIPMENT:\n\nPersonal Protective Equipment shall be provided for each Contractor employee by the Contractor. Possession of weapons are prohibited.\n\nSMOKING and VAPING POLICIES:\n\nSmoking and vaping are prohibited on Government property.\n\nPARKING:\n\nIt is the responsibility of Contractor personnel to park only in designated parking areas. Parking information is available from the VA Security Service. The VA shall not invalidate or make reimbursement for parking violations of the Contractor's personnel under any circumstances.\n\nCOMPLAINTS:\n\nContractor shall promptly and courteously respond to complaints within three (3) working days to the COR. Including complaints brought to the contractor s attention by the CO. Contractor shall maintain a written record of all complaints, both written and oral showing the identity of the individual, the nature of the complaint, and contractor s response. Contractor shall permit the Government to inspect the written records of complaints upon reasonable notice from the CO.\n\nNotice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov. Additionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be certified by the Small Business Administration; Veteran Small Business Certification, (VetCert) https://veterans.certify.sba.gov/. All interested Offerors should submit information by e-mail to: catherine.fernandezpedernera@va.gov .\n\nAll information submissions to be marked Attn: Catherine Fernandez, Contract Specialist and should be received no later than 10:00 AM PST on September 30, 2026.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26227Q0022","place_of_performance":{"zip":"92357","city":{"name":"Loma Linda"},"street":"Department of Veterans Affairs Loma Linda VA Health Care System 11201 Benton St.","country":{"code":"USA"}},"product_service_code":"J065"},{"dates":{"posted":"2026-10-30","posted_at":"2026-10-30T20:48:13.709Z","created_at":"2026-10-30T20:48:11.248Z","modified_at":"2026-10-30T20:48:13.709Z","response_deadline":{"raw":"2026-11-09T10:00:00-08:00","utc":"2026-11-09T18:00:00Z","date":"2026-11-09","time":"10:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/74391079a7f54655986d2066b40ef3f9/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-08","archive_type":"auto_custom"},"history":[{"index":2,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T20:48:13.709Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"74391079a7f54655986d2066b40ef3f9","solicitation_number":"36C26227Q0022","related_opportunity_id":"f2dd10e4902448de9bbde5be77c31a07"},{"index":1,"title":"J065--ANNUAL MEDICAL GAS TESTING Loma Linda VA POP: 12/01/2026 - 11/30/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-24T00:40:49.832Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"f2dd10e4902448de9bbde5be77c31a07","solicitation_number":"36C26227Q0022"}],"contacts":[{"name":"Catherine Fernandez","role":"primary","email":"Catherine.fernandezpedernera@va.gov","phone":"(480)-466-7937","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"74391079a7f54655986d2066b40ef3f9","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"f2dd10e4902448de9bbde5be77c31a07","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-31T04:12:06.896292057Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"af52296c9106dd943e14069dcd601245d76d219eb3374a2e4814642271720b8d","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-31T03:47:30.063427912Z"},"description":{"html":"This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2025-06 (eff. 10/01/2025), FAR Deviation NOV 2025 (eff. 11/19/2025), VAAR DEVIATION APR 2025 (eff. 04/01/2025), VAAM Alert 26-01 (eff. 10/01/2025), and Acquisition Policy Flash 26-23 eff. 11/19/2025).\n\nThis solicitation is set-aside for 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) concerns IAW FAR 19.1405 SDVOSB Set-aside procedures, and VAAR Subpart 819.70, the VA Veterans First Contracting Program.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 541380, with a small business size standard of $19 Million.\nThe FSC/PSC is H365.\n\nThe VA Loma Linda Healthcare System (VALLHCS), located at 11201 Benton Street, Loma Linda, CA 92357-1000 is seeking for a professional contractor to perform the annual medical gas distribution system inspection and testing.\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nRefer to Price/Cost Schedule (Attached)\n\nSTATEMENT OF WORK (SOW)\n\nTITLE:\n\n                        VA Loma Linda Healthcare System s (VALLHCS) Annual Med Gas Inspection\n\nBACKGROUND INFORMATION:\n\nVA Loma Linda Healthcare System s (VALLHCS) requires a new inspection contract for Medical Gas Distribution System. The Medical gas distribution system must undergo routine source and pipeline system inspections and maintenance to ensure continuous patient safety.\n\nOBJECTIVES:\n\nVA Loma Linda Healthcare System s (VALLHCS) Medical gas distribution system inspections shall comply with NFPA99 (Health Care Facilities Code), OSHA Life safety fire code, and the ASSE 6000 standard. They require annual central supply checks, routine alarm tests, and specialized third-party inspections by certified ASSE 6020 Inspectors. \n\nThe services performed shall conform to industry standards and this statement of work (SOW) and lockout and tagout procedures are to be done according to (OSHA Standard29 CFR 1910.147) VA Loma Linda Healthcare systems Policies and Regulations.\n\nSCOPE:\n\nContractors shall provide all labor, personnel, supplies, equipment, tools, materials, supervision and other necessary items. Inspection, testing and verification are mandatory for medical gas work and will be performed by licensed ASSE 6020 Medical Gas Inspectors and ASSE 6030 Medical Gas Verifiers.\nContractor shall perform Annual Medical Gas Distribution System Inspection on all Sources, Alarms, Zone Valves, and Patient Terminal Outlets / Inlets and bulk oxygen system.\n\nIncluding Areas as follows: \nMain Hospital\nFirst Floor:\nCLC, CLC Palliative Care, CLC Rehab, 1SW, Mod 3, Emergency department, \nSecond Floor: \nICU: 2SW, 2SE, \nThird Floor: \nOR 1 through 8, 3F-14, 3F-16, 3D-72, Recovery Room, SICU, X-Ray, MRI, Short Stay, G.I. Labs, 3NW, 3NE, 3SW, 3SE\nFourth Floor: 4NW, 4NE, 4SW, 4SE, Nuclear Med, Dialysis, Blood Laboratory, \n Oncology Building 31\n Eye Clinic Building 32\n Audiology Building 30\n\n  List of items provided for inspection:\n\nMedical Gas Sources \n\nMedical air compressors, vacuum pumps, gas manifolds, and any other device used to deliver medical gases to patients.\n\n1.Inventoried by location.\n2.Leak checked and documented.\n3.Recommendations to comply with NFPA 99, 2024 edition Health Care Facilities Code.\n\nMaster Alarm Panels \n\nAlarm panels are located at two separate locations throughout the facility. These panels monitor conditions directly from the medical gas sources.\n\n1.Inventoried by location\n2.Tested by removing existing pressure switches and other sensing devices to test the actuation points. No interruption of service is necessary if each device is mounted on code compliant demand fittings.\n3.Verify proper points are being monitored at each panel.\n4.Verify each panel is in the proper location.\n5.Verify proper labeling.\n\nArea Alarm Panels \n\nAlarm panels that are located throughout the facility monitor medical gas pressures for the area only.\n\n1.Inventoried by location.\n2.Tested by lowering pressure in each zone for each gas and documenting the alarm point.\n3.Verify proper location.\n4.Verify proper labeling.\n\nZone Valve Boxes \n\nAccessible valves typically found in a corridor covered by a plastic window used mostly for emergency purposes.\n\n1.Inventoried by location.\n2.Checked for leakage from packing, flange, and gauge port using oxygen safe leak detector.\n3.Verify proper labeling.\n4.Verify proper locations.\n\nMedical Gas Outlets/Inlets \n\nConnection points for each gas are located mostly in-patient areas.\n\n1.Inventoried by location in each room or area inspected left to right and then top to bottom.\n2.Complete an operational pressure test on each outlet and document pass/fail. (Test Parameters per NFPA 99, 2024 edition)\n3.Check function of outlet/inlet and latching mechanism.\n4.Check for leakage with equipment and without equipment attached.\n5.Document connection type and outlet/inlet manufacturer. \n\nOxygen Particulate Analysis \n\nParticulates are often found in existing medical gas systems due to improper installation methods that were used in the past.\n\n1.Samples are taken on each floor in each building.  \n\nMedical Air Dewpoint Analysis \n\nMoisture is removed from medical air systems at the source. Periodic Analysis of moisture throughout the facility is important to prevent possible contamination.\n\n1.Samples are taken on each floor in each building.  \n2.A sample will be taken at the medical air source to compare building samples.\n\nEmergency Oxygen Supply Connection Box \n\nThis box is typically mounted on the outside of a facility to facilitate the back feeding of the oxygen system if there is an interruption in service.\n\n1.Inventoried by location.\n2.Check existing location for proper compliance.\n3.Check existing piping arrangements to ensure proper order of components.\n4.Check to make sure box is secured.\n\nTesting to ensure all medical gas booms, and columns are leak free \n\nMost operating rooms and procedure rooms have some sort of device to help clinical personnel use the medical gases in the middle of the room by the patient. \nThese devices are either medical gas booms or columns. The hoses and threaded connections inside these devices need to be checked periodically to ensure that there are no leaks.\n\n1. All hoses and secondary equipment were removed from the outlets on each boom and column.\n2. A test pressure for each system was observed and documented.\n3. All medical gas valves were shut over a period of 10 minutes.\n4. After the test period of 10 minutes passed the pressure was observed once again.\n5. Any pressure drop was recorded.\n6. Recommendations will be made to find existing leaks and to make repairs.\n\nFacilities responsibility:\n\nA.  The facility shall coordinate with all departments to notify of the medical gas/vacuum system inspection and or repairs to be completed.\nB. The facility shall supply Inspecting personnel with facility maintenance personnel to unlock secured areas that have medical gas/vacuum systems, or a master key may also be supplied to complete inspection services.\n\nREPORTS:\n\nThe contractor will annotate compliance with ASSE 6000, 6020 and 6030 Medical Gas specifications and requirements by submitting a detailed PM report to the Contracting Officer s Representative (COR) along with pictures for each equipment, after PM is completed. The reports shall be submitted to COR, within 14 days of work completion. The contractor shall provide additional reports as required by the COR.  \nThe contractor s report shall show the information listed below. The report shall contain, at a minimum, any other information required by the COR and all applicable NFPA and Joint Commission and OSHA specifications, the following:\n\nDate of P.M.\nTime of P.M.\nIdentification of the equipment descriptions, manufacturer, and serial number\nLocation of equipment under P.M. or repair\nProbable cause of repairs\nCorrection action (servicing, repair or replacement) \nWho was notified?\nComments and recommendations.\nCompletion date\n\nContractor shall complete scheduled preventive maintenance service, inspection and repairs to NFPA and Joint Commission and OSHA requirements for the Medical Gas Distribution System.\n\nOVER AND ABOVE REPAIR:\n\nUpon discovery of over and above repairs or unforeseen requirements, Contractor shall\nimmediately notify the POC. Parts shall not be procured, nor installation or repairs initiated until approval is obtained from the Contracting Officer and appropriate Facilities Staff/POC. Charges for repair, labor and parts shall originate only when required and upon prior approval being granted by the Contracting Officer. Any additional work performed must be by licensed ASSE 6010 Medical Gas System Installers and ASSE 6040 Medical Gas System Maintenance Personnel.\n\nPERIOD OF PERFORMANCE:\n\nBase Plus Four from performance start date.  Work may be scheduled during the day or night (Depending on load demand), Monday thru Friday and/or Saturday thru Sunday.\n\nDaytime hours: 6 am to 4 pm \nEvening hours: 4 pm to 4 am \n\nContractor shall initiate work within 2 weeks of being contacted by the designated Contracting Officer s Point of Contact (POC) or designee. Work shall be scheduled through the POC or designee, who will coordinate with VALLHCS staff. Timelines are subject to change due to VALLHCS operational requirements.  \n\nPLACE OF PERFORMANCE:\n\n        VA Loma Linda 11201 Benton St. Loma Linda, CA   92357\n\nLICENSING REQUIREMENTS:\n\nOfferor must possess a 30-hour Occupational Safety and Health Administration (OSHA) safety card.\nASSE Medical Gas Verifier 6030\nASSE Medical Gas inspector 6020\n\nSPECIFIC REQUIREMENTS:\n\nContractor shall schedule start date with POC or designee five (5) business days in advance.\nContactor personnel shall have valid Loma Linda PIV badges before starting work.\nContractor shall coordinate energy source LOCK OUT /TAG OUT procedures with VALLHCS Electrical Supervisor before starting work. When work is complete, Contractor shall notify the VALLHCS Electrical Supervisor that energy sources will be restored and require verification.\nContractor s supervisor or lead technician are to check in with VALLHCS Electrical Supervisor, or in their absence, with Graphics Control prior to work each day.\nContractor shall conform to the following standards, policies, regulations, governing agency, and any other local, state, or Federal guidelines that are not listed here.\nOSHA 29CFR Regulations, www.osha.gov \nNFPA 99, www.nfpa.org\nChapter 5 Gas and Vacuum Systems\n5.1 Category 1 Piped Gas and Vacuum Systems\n5.2 Category 2 Piped Gas and Vacuum Systems\n5.3 Category 3 Piped Gas and Vacuum Systems\nASSE\n\nAUTHORIZED SERVICES:\n\nOnly those services specified herein are authorized under this contract. Before permitting and/or performing any service of a non-contract nature, the Contractor shall advise the CO of the reason (s) for the additional work and/or service. The Contractor is cautioned that only the CO or his/her designee may authorize additional service that are within the scope of this contract and that reimbursement shall not be made unless prior authorization is obtained from the CO. All changes to the contract shall be issued through a contract modification in writing from the CO to the Contractor.\n\nDELEGATION OF AUTHORITY:\n\nNo additional service shall be provided without the approval from the Contracting Officer (CO) or his/her designee of this contract. The Contractor shall not accept any instructions issued by any other person(s) other than the CO or his/her delegated representative acting within the limits of his/her authority.\n\nGOVERNMENT-FURNISHED EQUIPMENT (GFE) GOVERNMENT FURNISHED INFORMATION (GFI):\n\n       No Government equipment will be used by the Vendor.\n\nRECOGNIZED HOLIDAYS:\n\nThe following is a list of all Government recognized holidays:\n\nIn accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following National holidays  are observed and for the purpose of this contract are defined as  Legal Federal official holidays :\n\nNew Year s Day: January 1\nMartin Luther King  s Birthday: Third Monday in January\nPresident s Day: Third Monday in February\nMemorial Day: Last Monday in May\nJuneteenth Independence Day: June 19\nIndependence Day: July 4\nLabor Day: First Monday in September\nColumbus Day: Second Monday in October\nVeterans Day: November 11\nThanksgiving Day: Fourth Thursday in November\nChristmas Day: December 25\n\n     If a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When    a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nCONTRACTOR EMPLOYEES AND BADGES:\n\n    Contractor personnel shall present a neat appearance and be easily recognized as Contractor    employees. Examples: wearing of distinctive clothing such as uniform, badges, patches, etc.\n\nAll contractor personnel shall be required to wear VA provided identification (I.D.) badges above the waist at all times while on the VA grounds. Contractor shall be required to coordinate with the COR to obtain the VA provided I.D. badges for all staff. All VA provided I.D. badges shall be returned at the end of the contract or upon completion of service. Failure to wear ID badges may result in removal from any of the VA facilities and/or otherwise referred to Government property.\n\nSAFETY AND PPE EQUIPMENT:\n\n  Personal Protective Equipment shall be provided for each Contractor employee by the    Contractor. Possession of weapons are prohibited.  \n\nSMOKING and VAPING POLICIES:\n\n      Smoking and vaping are prohibited on Government property.\n\nPARKING:\n\nIt is the responsibility of Contractor personnel to park only in designated parking areas. Parking information is    available from the VA Security Service. The VA shall not invalidate or make reimbursement for parking violations of the Contractor's personnel under any circumstances.     \n\nCOMPLAINTS:\n\nContractor shall promptly and courteously respond to complaints within three (3) working days to the COR. Including complaints brought to the contractor s attention by the CO. Contractor shall maintain a written record of all complaints, both written and oral showing the identity of the individual, the nature of the complaint, and contractor s response. Contractor shall permit the Government to inspect the written records of complaints upon reasonable notice from the CO.\n**End of Statement of Work**\n\nThe purchase order period of performance is 11/09/2026 - 11/08/2031.\n\nFree on Board Origin (FOB) is destination.\n\nPlace of Performance/Place of Delivery\n\nAddress:\nDepartment of Veterans Affairs\nVA Loma Linda Healthcare System (VALLHCS)\nJerry L. Pettis VA Medical Center (VAMC)\n11201 Benton Street\nLoma Linda, CA\nPostal Code:\n92357-1000\nCountry:\nUNITED STATES\n\nThe full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far. \n\nThe following solicitation provisions and clause apply to this acquisition:\n\nFAR 52.212-1,  Instructions to Offerors-Commercial Products and Commercial Services (SEP 2023) (DEVIATION OCT 2025) \nFAR 52.252-1,  Solicitation Provisions Incorporated by Reference (FEB 1998) \nFAR 52.203-18,  Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements-Representation. (JAN 2017) \nFAR 52.204-7,  System for Award Management Registration. (NOV 2024) (DEVIATION NOV 2025) \nFAR 52.217-3,  Evaluation Exclusive of Options (APR 1983) \nFAR 52.229-11,  Tax on Certain Foreign Procurements   Notice and Representation (NOV 2007)(DEVEATION SEP 2025)  RC\nFAR 52.217-5,  Evaluation of Options. (JULY 1990) (DEVIATION NOV 2025) \nFAR 52.216-1,  Type of Contract (APR 1984) (DEVIATION NOV 2025)  \nFAR 52.219-1,  Small Business Program Representations. (FEB 2024) (DEVIATION NOV 2025)  \nFAR 52.252-5,  Authorized Deviations in Provisions (NOV 2020)  \nVAAR 852.209-70,  Organizational Conflicts of Interest (OCT 2026) (DEVIATION) \nVAAR 852.273-74,  Award without Negotiations (OCT 2026) (DEVIATION) \n\nVAAR 852.252-70,  Solicitation Provisions or Clauses Incorporated by Reference (JAN 2008)  \nThe following contract clauses apply to this acquisition: \n\nFAR 52.212-4,  Contract Terms and Conditions-Commercial Products and Commercial Services. (NOV 2023) (DEVIATION OCT 2025) \nFAR 52.252-2,  Clauses Incorporated by Reference. (FEB 1998)  \nFAR 52.203-17,  Contractor Employee Whistleblower Rights. (NOV 2023) \nFAR 52.203-19,  Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements. (JAN 2017) \nFAR 52.204-9,  Personal Identity Verification of Contractor Personnel (JAN 2011) \nFAR 52.204-13,  System for Award Management-Maintenance. (OCT 2018) (DEVIATION NOV 2025) \nFAR 52.209-6,  Protecting the Government's Interest When Subcontracting With Contractors Debarred, Suspended, Proposed for Debarment, or Voluntarily Excluded. (JAN 2025) (DEVIATION NOV 2025) \nFAR 52.209-10,  Prohibition on Contracting With Inverted Domestic Corporations. (NOV 2015) (DEVIATION NOV 2025) \nFAR 52.217-8,  Option to Extend Services (NOV 1999) \nFAR 52.217-9,  Option to Extend the Term of the Contract (MAR 2000) \nFAR 52.219-4,  Notice of Price Evaluation Preference for HUBZone Small Business Concerns. (OCT 2022) (DEVIATION NOV 2025) \nFAR 52.219-6,  Notice of Total Small Business Set-Aside. (NOV 2020) (DEVIATION NOV 2025) \nFAR 52.219-28,  Post award Small Business Program Rerepresentation (JAN 2025) (DEVIATION NOV 2025) \nFAR 52.222-36,  Equal Opportunity for Workers with Disabilities. (JUN 2020) (DEVIATION NOV 2025) \nFAR 52.222-41,  Service Contract Labor Standards. (AUG 2018) (DEVIATION NOV 2025) \nFAR 52.222-42,  Statement of Equivalent Rates for Federal Hires. (MAY 2014) \nFAR 52.222-43,  Fair Labor Standards Act and Service Contract Labor Standards-Price Adjustment (Multiple Year and Option Contracts). (AUG 2018) (DEVIATION NOV 2025) \nFAR 52.222-50,  Combating Trafficking in Persons. (NOV 2021) (DEVIATION NOV 2025) \nFAR 52.222-55,  Minimum Wages for Contractor Workers Under Executive Order 14026 (JAN 2022) (DEVIATION NOV 2025) \nFAR 52.222-62,  Paid Sick Leave Under Executive Order 13706. (JAN 2022) (DEVIATION NOV 2025) \nFAR 52.223-5,  Pollution Prevention and Right-to-Know Information (MAY 2024) \nFAR 52.226-8,  Encouraging Contractor Policies to Ban Text Messaging While Driving. (MAY 2024) \nFAR 52.232-33,  Payment by Electronic Funds Transfer-System for Award Management. (OCT 2018) \nFAR 52.232-40,  Providing Accelerated Payments to Small Business Subcontractors. (MAR 2023) \nFAR 52.233-3,  Protest after Award. (AUG 1996) (DEVIATION NOV 2025) \nFAR 52.233-4,  Applicable Law for Breach of Contract Claim. (OCT 2004) (DEVIATION NOV 2025) \nFAR 52.244-6,  Subcontracts for Commercial Products and Commercial Services. (Jan 2025) (DEVIATION APR 2026) \nFAR 52.222-90,  Addressing DEI Discrimination by Federal Contractors (APR 2026)  FC\nFAR 52.240-91,  Security Prohibitions and Exclusions. (DEVIATION NOV 2025)  \nFAR 52.240-92,  Security Requirements. (DEVIATION NOV 2025)  \nFAR 52.252-6,  Authorized Deviations in Clauses (NOV 2020)  \nVAAR 852.203-70,  Commercial Advertising (MAY 2018)  \nVAAR 852.204-70,  Personal Identity Verification of Contractor Personnel (OCT 2026) (DEVIATION)  \nVAR 852.219-74,  VA Notice of Total Set-Aside for Veteran-Owned Small Businesses (OCT 2026) (DEVIATION)  \nVAAR 852.232-72,  Electronic Submission of Payment Requests (OCT 2026) (DEVIATION) \nVAAR 852.204-72,  Personnel Vetting and Credentialing (OCT 2026) (DEVIATION)  \nVAAR 852.219-75,  VA Notice of Limitations on Subcontracting   Certificate of Compliance for Services and Construction (JAN 2023) (DEVIATION)  \nAll Invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests. This is accomplished through the Tungsten Network located at: http://www.fsc.va.gov/einvoice.asp. This is mandatory and the sole method for submitting invoices.\n\nAll quoters shall submit the following: All information required by FAR 52.212-1(b) Submission of Offers to include, but not limited to, SAM UEI.\n\nAll quotes shall be sent to the Network Contracting Office (NCO) Catherine.fernandezpedernera@va.gov\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.\n\nThe following are the decision factors: Price, and past performance, with price more important.\n\nPast performance will be based on CPARS and FAPIIS ratings. No rating in CPARS is equal to a neutral rating.\n\nLICENSING REQUIREMENTS:\nÂ \nOfferor must possess a 30-hour Occupational Safety and Health Administration (OSHA) safety card.\nASSE Medical Gas Verifier 6030\nASSE Medical Gas inspector 6020\nThe award will be made to the response most advantageous to the Government.\nResponses should contain your best terms, conditions.\n*** Licenses must be submitted with the solicitation. \n\nNOTE: RFO FAR 52.212-3 is RESERVED and replaced with: https://sam.gov/ registration is required to be complete at time of submission of response. Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/.\n\nFAR 52.212-4,  Contract Terms and Conditions Commercial Products and Commercial Services  (NOV 2023) (DEVIATION OCT 2025)\n\nAddenda to FAR 52.212-4 are attached.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\n\n Quoters shall list exception(s) and rationale for the exception(s), if any.\n\nNote: It is  Encouraged  for all interested parties to attend the site visit on the date and time stated below.\nSite visit: Site visit will be conducted by the COR Raymond Stockman,Â Raymond.Stockman@va.govÂ  909-841-1782 on November 04, 2026 at 11:00 am (PST) and will meet at the front main lobby located at 11201 Benton St., Loma Linda CA 92357.Â  Please email Raymond Stockman.  Â RSVP with your contact information if you plan to attend the site visit. Contractors are to measure on site visit areas.\nQuestions shall be received electronically only not later than 10:00 PDT on 11/05/2026 at Catherine.fernandezpedernera@va.gov.\n\nSubmission of your final response shall be received electronically not later than 10:00 AM PDT on 11/09/2026 at Catherine.fernandezpedernera@va.gov. Subject line should include  RESPONSE TO RFQ 36C26226Q0022. \n\nSubmissions shall include your quote using the attached schedule as well as a capabilities statement with qualifications proving all certifications and education required for the work being conducted in the SOW. Submissions NOT meeting all requirements of the SOW will be considered ineligible for award.\n\nQuotes should be based on the information provided as no discussions will be allowed. This solicitation is being made under FAR 12.201-1 Simplified Procedures.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Phone calls with questions will not be accepted.\n\nPoint of Contact\nCatherine Fernadez, Contract Specialist, Catherine.fernandezpedernera@va.gov.","text":"This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2025-06 (eff. 10/01/2025), FAR Deviation NOV 2025 (eff. 11/19/2025), VAAR DEVIATION APR 2025 (eff. 04/01/2025), VAAM Alert 26-01 (eff. 10/01/2025), and Acquisition Policy Flash 26-23 eff. 11/19/2025).\n\nThis solicitation is set-aside for 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) concerns IAW FAR 19.1405 SDVOSB Set-aside procedures, and VAAR Subpart 819.70, the VA Veterans First Contracting Program.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 541380, with a small business size standard of $19 Million.\nThe FSC/PSC is H365.\n\nThe VA Loma Linda Healthcare System (VALLHCS), located at 11201 Benton Street, Loma Linda, CA 92357-1000 is seeking for a professional contractor to perform the annual medical gas distribution system inspection and testing.\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nRefer to Price/Cost Schedule (Attached)\n\nSTATEMENT OF WORK (SOW)\n\nTITLE:\n\nVA Loma Linda Healthcare System s (VALLHCS) Annual Med Gas Inspection\n\nBACKGROUND INFORMATION:\n\nVA Loma Linda Healthcare System s (VALLHCS) requires a new inspection contract for Medical Gas Distribution System. The Medical gas distribution system must undergo routine source and pipeline system inspections and maintenance to ensure continuous patient safety.\n\nOBJECTIVES:\n\nVA Loma Linda Healthcare System s (VALLHCS) Medical gas distribution system inspections shall comply with NFPA99 (Health Care Facilities Code), OSHA Life safety fire code, and the ASSE 6000 standard. They require annual central supply checks, routine alarm tests, and specialized third-party inspections by certified ASSE 6020 Inspectors.\n\nThe services performed shall conform to industry standards and this statement of work (SOW) and lockout and tagout procedures are to be done according to (OSHA Standard29 CFR 1910.147) VA Loma Linda Healthcare systems Policies and Regulations.\n\nSCOPE:\n\nContractors shall provide all labor, personnel, supplies, equipment, tools, materials, supervision and other necessary items. Inspection, testing and verification are mandatory for medical gas work and will be performed by licensed ASSE 6020 Medical Gas Inspectors and ASSE 6030 Medical Gas Verifiers.\nContractor shall perform Annual Medical Gas Distribution System Inspection on all Sources, Alarms, Zone Valves, and Patient Terminal Outlets / Inlets and bulk oxygen system.\n\nIncluding Areas as follows:\nMain Hospital\nFirst Floor:\nCLC, CLC Palliative Care, CLC Rehab, 1SW, Mod 3, Emergency department,\nSecond Floor:\nICU: 2SW, 2SE,\nThird Floor:\nOR 1 through 8, 3F-14, 3F-16, 3D-72, Recovery Room, SICU, X-Ray, MRI, Short Stay, G.I. Labs, 3NW, 3NE, 3SW, 3SE\nFourth Floor: 4NW, 4NE, 4SW, 4SE, Nuclear Med, Dialysis, Blood Laboratory,\nOncology Building 31\nEye Clinic Building 32\nAudiology Building 30\n\nList of items provided for inspection:\n\nMedical Gas Sources\n\nMedical air compressors, vacuum pumps, gas manifolds, and any other device used to deliver medical gases to patients.\n\n1.Inventoried by location.\n2.Leak checked and documented.\n3.Recommendations to comply with NFPA 99, 2024 edition Health Care Facilities Code.\n\nMaster Alarm Panels\n\nAlarm panels are located at two separate locations throughout the facility. These panels monitor conditions directly from the medical gas sources.\n\n1.Inventoried by location\n2.Tested by removing existing pressure switches and other sensing devices to test the actuation points. No interruption of service is necessary if each device is mounted on code compliant demand fittings.\n3.Verify proper points are being monitored at each panel.\n4.Verify each panel is in the proper location.\n5.Verify proper labeling.\n\nArea Alarm Panels\n\nAlarm panels that are located throughout the facility monitor medical gas pressures for the area only.\n\n1.Inventoried by location.\n2.Tested by lowering pressure in each zone for each gas and documenting the alarm point.\n3.Verify proper location.\n4.Verify proper labeling.\n\nZone Valve Boxes\n\nAccessible valves typically found in a corridor covered by a plastic window used mostly for emergency purposes.\n\n1.Inventoried by location.\n2.Checked for leakage from packing, flange, and gauge port using oxygen safe leak detector.\n3.Verify proper labeling.\n4.Verify proper locations.\n\nMedical Gas Outlets/Inlets\n\nConnection points for each gas are located mostly in-patient areas.\n\n1.Inventoried by location in each room or area inspected left to right and then top to bottom.\n2.Complete an operational pressure test on each outlet and document pass/fail. (Test Parameters per NFPA 99, 2024 edition)\n3.Check function of outlet/inlet and latching mechanism.\n4.Check for leakage with equipment and without equipment attached.\n5.Document connection type and outlet/inlet manufacturer.\n\nOxygen Particulate Analysis\n\nParticulates are often found in existing medical gas systems due to improper installation methods that were used in the past.\n\n1.Samples are taken on each floor in each building.\n\nMedical Air Dewpoint Analysis\n\nMoisture is removed from medical air systems at the source. Periodic Analysis of moisture throughout the facility is important to prevent possible contamination.\n\n1.Samples are taken on each floor in each building.\n2.A sample will be taken at the medical air source to compare building samples.\n\nEmergency Oxygen Supply Connection Box\n\nThis box is typically mounted on the outside of a facility to facilitate the back feeding of the oxygen system if there is an interruption in service.\n\n1.Inventoried by location.\n2.Check existing location for proper compliance.\n3.Check existing piping arrangements to ensure proper order of components.\n4.Check to make sure box is secured.\n\nTesting to ensure all medical gas booms, and columns are leak free\n\nMost operating rooms and procedure rooms have some sort of device to help clinical personnel use the medical gases in the middle of the room by the patient.\nThese devices are either medical gas booms or columns. The hoses and threaded connections inside these devices need to be checked periodically to ensure that there are no leaks.\n\n1. All hoses and secondary equipment were removed from the outlets on each boom and column.\n2. A test pressure for each system was observed and documented.\n3. All medical gas valves were shut over a period of 10 minutes.\n4. After the test period of 10 minutes passed the pressure was observed once again.\n5. Any pressure drop was recorded.\n6. Recommendations will be made to find existing leaks and to make repairs.\n\nFacilities responsibility:\n\nA. The facility shall coordinate with all departments to notify of the medical gas/vacuum system inspection and or repairs to be completed.\nB. The facility shall supply Inspecting personnel with facility maintenance personnel to unlock secured areas that have medical gas/vacuum systems, or a master key may also be supplied to complete inspection services.\n\nREPORTS:\n\nThe contractor will annotate compliance with ASSE 6000, 6020 and 6030 Medical Gas specifications and requirements by submitting a detailed PM report to the Contracting Officer s Representative (COR) along with pictures for each equipment, after PM is completed. The reports shall be submitted to COR, within 14 days of work completion. The contractor shall provide additional reports as required by the COR.\nThe contractor s report shall show the information listed below. The report shall contain, at a minimum, any other information required by the COR and all applicable NFPA and Joint Commission and OSHA specifications, the following:\n\nDate of P.M.\nTime of P.M.\nIdentification of the equipment descriptions, manufacturer, and serial number\nLocation of equipment under P.M. or repair\nProbable cause of repairs\nCorrection action (servicing, repair or replacement)\nWho was notified?\nComments and recommendations.\nCompletion date\n\nContractor shall complete scheduled preventive maintenance service, inspection and repairs to NFPA and Joint Commission and OSHA requirements for the Medical Gas Distribution System.\n\nOVER AND ABOVE REPAIR:\n\nUpon discovery of over and above repairs or unforeseen requirements, Contractor shall\nimmediately notify the POC. Parts shall not be procured, nor installation or repairs initiated until approval is obtained from the Contracting Officer and appropriate Facilities Staff/POC. Charges for repair, labor and parts shall originate only when required and upon prior approval being granted by the Contracting Officer. Any additional work performed must be by licensed ASSE 6010 Medical Gas System Installers and ASSE 6040 Medical Gas System Maintenance Personnel.\n\nPERIOD OF PERFORMANCE:\n\nBase Plus Four from performance start date. Work may be scheduled during the day or night (Depending on load demand), Monday thru Friday and/or Saturday thru Sunday.\n\nDaytime hours: 6 am to 4 pm\nEvening hours: 4 pm to 4 am\n\nContractor shall initiate work within 2 weeks of being contacted by the designated Contracting Officer s Point of Contact (POC) or designee. Work shall be scheduled through the POC or designee, who will coordinate with VALLHCS staff. Timelines are subject to change due to VALLHCS operational requirements.\n\nPLACE OF PERFORMANCE:\n\nVA Loma Linda 11201 Benton St. Loma Linda, CA 92357\n\nLICENSING REQUIREMENTS:\n\nOfferor must possess a 30-hour Occupational Safety and Health Administration (OSHA) safety card.\nASSE Medical Gas Verifier 6030\nASSE Medical Gas inspector 6020\n\nSPECIFIC REQUIREMENTS:\n\nContractor shall schedule start date with POC or designee five (5) business days in advance.\nContactor personnel shall have valid Loma Linda PIV badges before starting work.\nContractor shall coordinate energy source LOCK OUT /TAG OUT procedures with VALLHCS Electrical Supervisor before starting work. When work is complete, Contractor shall notify the VALLHCS Electrical Supervisor that energy sources will be restored and require verification.\nContractor s supervisor or lead technician are to check in with VALLHCS Electrical Supervisor, or in their absence, with Graphics Control prior to work each day.\nContractor shall conform to the following standards, policies, regulations, governing agency, and any other local, state, or Federal guidelines that are not listed here.\nOSHA 29CFR Regulations, www.osha.gov\nNFPA 99, www.nfpa.org\nChapter 5 Gas and Vacuum Systems\n5.1 Category 1 Piped Gas and Vacuum Systems\n5.2 Category 2 Piped Gas and Vacuum Systems\n5.3 Category 3 Piped Gas and Vacuum Systems\nASSE\n\nAUTHORIZED SERVICES:\n\nOnly those services specified herein are authorized under this contract. Before permitting and/or performing any service of a non-contract nature, the Contractor shall advise the CO of the reason (s) for the additional work and/or service. The Contractor is cautioned that only the CO or his/her designee may authorize additional service that are within the scope of this contract and that reimbursement shall not be made unless prior authorization is obtained from the CO. All changes to the contract shall be issued through a contract modification in writing from the CO to the Contractor.\n\nDELEGATION OF AUTHORITY:\n\nNo additional service shall be provided without the approval from the Contracting Officer (CO) or his/her designee of this contract. The Contractor shall not accept any instructions issued by any other person(s) other than the CO or his/her delegated representative acting within the limits of his/her authority.\n\nGOVERNMENT-FURNISHED EQUIPMENT (GFE) GOVERNMENT FURNISHED INFORMATION (GFI):\n\nNo Government equipment will be used by the Vendor.\n\nRECOGNIZED HOLIDAYS:\n\nThe following is a list of all Government recognized holidays:\n\nIn accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following National holidays are observed and for the purpose of this contract are defined as Legal Federal official holidays :\n\nNew Year s Day: January 1\nMartin Luther King s Birthday: Third Monday in January\nPresident s Day: Third Monday in February\nMemorial Day: Last Monday in May\nJuneteenth Independence Day: June 19\nIndependence Day: July 4\nLabor Day: First Monday in September\nColumbus Day: Second Monday in October\nVeterans Day: November 11\nThanksgiving Day: Fourth Thursday in November\nChristmas Day: December 25\n\nIf a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nCONTRACTOR EMPLOYEES AND BADGES:\n\nContractor personnel shall present a neat appearance and be easily recognized as Contractor employees. Examples: wearing of distinctive clothing such as uniform, badges, patches, etc.\n\nAll contractor personnel shall be required to wear VA provided identification (I.D.) badges above the waist at all times while on the VA grounds. Contractor shall be required to coordinate with the COR to obtain the VA provided I.D. badges for all staff. All VA provided I.D. badges shall be returned at the end of the contract or upon completion of service. Failure to wear ID badges may result in removal from any of the VA facilities and/or otherwise referred to Government property.\n\nSAFETY AND PPE EQUIPMENT:\n\nPersonal Protective Equipment shall be provided for each Contractor employee by the Contractor. Possession of weapons are prohibited.\n\nSMOKING and VAPING POLICIES:\n\nSmoking and vaping are prohibited on Government property.\n\nPARKING:\n\nIt is the responsibility of Contractor personnel to park only in designated parking areas. Parking information is available from the VA Security Service. The VA shall not invalidate or make reimbursement for parking violations of the Contractor's personnel under any circumstances.\n\nCOMPLAINTS:\n\nContractor shall promptly and courteously respond to complaints within three (3) working days to the COR. Including complaints brought to the contractor s attention by the CO. Contractor shall maintain a written record of all complaints, both written and oral showing the identity of the individual, the nature of the complaint, and contractor s response. Contractor shall permit the Government to inspect the written records of complaints upon reasonable notice from the CO.\n**End of Statement of Work**\n\nThe purchase order period of performance is 11/09/2026 - 11/08/2031.\n\nFree on Board Origin (FOB) is destination.\n\nPlace of Performance/Place of Delivery\n\nAddress:\nDepartment of Veterans Affairs\nVA Loma Linda Healthcare System (VALLHCS)\nJerry L. Pettis VA Medical Center (VAMC)\n11201 Benton Street\nLoma Linda, CA\nPostal Code:\n92357-1000\nCountry:\nUNITED STATES\n\nThe full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far.\n\nThe following solicitation provisions and clause apply to this acquisition:\n\nFAR 52.212-1, Instructions to Offerors-Commercial Products and Commercial Services (SEP 2023) (DEVIATION OCT 2025)\nFAR 52.252-1, Solicitation Provisions Incorporated by Reference (FEB 1998)\nFAR 52.203-18, Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements or Statements-Representation. (JAN 2017)\nFAR 52.204-7, System for Award Management Registration. (NOV 2024) (DEVIATION NOV 2025)\nFAR 52.217-3, Evaluation Exclusive of Options (APR 1983)\nFAR 52.229-11, Tax on Certain Foreign Procurements Notice and Representation (NOV 2007)(DEVEATION SEP 2025) RC\nFAR 52.217-5, Evaluation of Options. (JULY 1990) (DEVIATION NOV 2025)\nFAR 52.216-1, Type of Contract (APR 1984) (DEVIATION NOV 2025)\nFAR 52.219-1, Small Business Program Representations. (FEB 2024) (DEVIATION NOV 2025)\nFAR 52.252-5, Authorized Deviations in Provisions (NOV 2020)\nVAAR 852.209-70, Organizational Conflicts of Interest (OCT 2026) (DEVIATION)\nVAAR 852.273-74, Award without Negotiations (OCT 2026) (DEVIATION)\n\nVAAR 852.252-70, Solicitation Provisions or Clauses Incorporated by Reference (JAN 2008)\nThe following contract clauses apply to this acquisition:\n\nFAR 52.212-4, Contract Terms and Conditions-Commercial Products and Commercial Services. (NOV 2023) (DEVIATION OCT 2025)\nFAR 52.252-2, Clauses Incorporated by Reference. (FEB 1998)\nFAR 52.203-17, Contractor Employee Whistleblower Rights. (NOV 2023)\nFAR 52.203-19, Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements. (JAN 2017)\nFAR 52.204-9, Personal Identity Verification of Contractor Personnel (JAN 2011)\nFAR 52.204-13, System for Award Management-Maintenance. (OCT 2018) (DEVIATION NOV 2025)\nFAR 52.209-6, Protecting the Government's Interest When Subcontracting With Contractors Debarred, Suspended, Proposed for Debarment, or Voluntarily Excluded. (JAN 2025) (DEVIATION NOV 2025)\nFAR 52.209-10, Prohibition on Contracting With Inverted Domestic Corporations. (NOV 2015) (DEVIATION NOV 2025)\nFAR 52.217-8, Option to Extend Services (NOV 1999)\nFAR 52.217-9, Option to Extend the Term of the Contract (MAR 2000)\nFAR 52.219-4, Notice of Price Evaluation Preference for HUBZone Small Business Concerns. (OCT 2022) (DEVIATION NOV 2025)\nFAR 52.219-6, Notice of Total Small Business Set-Aside. (NOV 2020) (DEVIATION NOV 2025)\nFAR 52.219-28, Post award Small Business Program Rerepresentation (JAN 2025) (DEVIATION NOV 2025)\nFAR 52.222-36, Equal Opportunity for Workers with Disabilities. (JUN 2020) (DEVIATION NOV 2025)\nFAR 52.222-41, Service Contract Labor Standards. (AUG 2018) (DEVIATION NOV 2025)\nFAR 52.222-42, Statement of Equivalent Rates for Federal Hires. (MAY 2014)\nFAR 52.222-43, Fair Labor Standards Act and Service Contract Labor Standards-Price Adjustment (Multiple Year and Option Contracts). (AUG 2018) (DEVIATION NOV 2025)\nFAR 52.222-50, Combating Trafficking in Persons. (NOV 2021) (DEVIATION NOV 2025)\nFAR 52.222-55, Minimum Wages for Contractor Workers Under Executive Order 14026 (JAN 2022) (DEVIATION NOV 2025)\nFAR 52.222-62, Paid Sick Leave Under Executive Order 13706. (JAN 2022) (DEVIATION NOV 2025)\nFAR 52.223-5, Pollution Prevention and Right-to-Know Information (MAY 2024)\nFAR 52.226-8, Encouraging Contractor Policies to Ban Text Messaging While Driving. (MAY 2024)\nFAR 52.232-33, Payment by Electronic Funds Transfer-System for Award Management. (OCT 2018)\nFAR 52.232-40, Providing Accelerated Payments to Small Business Subcontractors. (MAR 2023)\nFAR 52.233-3, Protest after Award. (AUG 1996) (DEVIATION NOV 2025)\nFAR 52.233-4, Applicable Law for Breach of Contract Claim. (OCT 2004) (DEVIATION NOV 2025)\nFAR 52.244-6, Subcontracts for Commercial Products and Commercial Services. (Jan 2025) (DEVIATION APR 2026)\nFAR 52.222-90, Addressing DEI Discrimination by Federal Contractors (APR 2026) FC\nFAR 52.240-91, Security Prohibitions and Exclusions. (DEVIATION NOV 2025)\nFAR 52.240-92, Security Requirements. (DEVIATION NOV 2025)\nFAR 52.252-6, Authorized Deviations in Clauses (NOV 2020)\nVAAR 852.203-70, Commercial Advertising (MAY 2018)\nVAAR 852.204-70, Personal Identity Verification of Contractor Personnel (OCT 2026) (DEVIATION)\nVAR 852.219-74, VA Notice of Total Set-Aside for Veteran-Owned Small Businesses (OCT 2026) (DEVIATION)\nVAAR 852.232-72, Electronic Submission of Payment Requests (OCT 2026) (DEVIATION)\nVAAR 852.204-72, Personnel Vetting and Credentialing (OCT 2026) (DEVIATION)\nVAAR 852.219-75, VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction (JAN 2023) (DEVIATION)\nAll Invoices from the contractor shall be submitted electronically in accordance with VAAR Clause 852.232-72 Electronic Submission of Payment Requests. This is accomplished through the Tungsten Network located at: http://www.fsc.va.gov/einvoice.asp. This is mandatory and the sole method for submitting invoices.\n\nAll quoters shall submit the following: All information required by FAR 52.212-1(b) Submission of Offers to include, but not limited to, SAM UEI.\n\nAll quotes shall be sent to the Network Contracting Office (NCO) Catherine.fernandezpedernera@va.gov\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.\n\nThe following are the decision factors: Price, and past performance, with price more important.\n\nPast performance will be based on CPARS and FAPIIS ratings. No rating in CPARS is equal to a neutral rating.\n\nLICENSING REQUIREMENTS:\nÂ\nOfferor must possess a 30-hour Occupational Safety and Health Administration (OSHA) safety card.\nASSE Medical Gas Verifier 6030\nASSE Medical Gas inspector 6020\nThe award will be made to the response most advantageous to the Government.\nResponses should contain your best terms, conditions.\n*** Licenses must be submitted with the solicitation.\n\nNOTE: RFO FAR 52.212-3 is RESERVED and replaced with: https://sam.gov/ registration is required to be complete at time of submission of response. Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/.\n\nFAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (NOV 2023) (DEVIATION OCT 2025)\n\nAddenda to FAR 52.212-4 are attached.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\n\nQuoters shall list exception(s) and rationale for the exception(s), if any.\n\nNote: It is Encouraged for all interested parties to attend the site visit on the date and time stated below.\nSite visit: Site visit will be conducted by the COR Raymond Stockman,Â Raymond.Stockman@va.govÂ 909-841-1782 on November 04, 2026 at 11:00 am (PST) and will meet at the front main lobby located at 11201 Benton St., Loma Linda CA 92357.Â Please email Raymond Stockman. Â RSVP with your contact information if you plan to attend the site visit. Contractors are to measure on site visit areas.\nQuestions shall be received electronically only not later than 10:00 PDT on 11/05/2026 at Catherine.fernandezpedernera@va.gov.\n\nSubmission of your final response shall be received electronically not later than 10:00 AM PDT on 11/09/2026 at Catherine.fernandezpedernera@va.gov. Subject line should include RESPONSE TO RFQ 36C26226Q0022.\n\nSubmissions shall include your quote using the attached schedule as well as a capabilities statement with qualifications proving all certifications and education required for the work being conducted in the SOW. Submissions NOT meeting all requirements of the SOW will be considered ineligible for award.\n\nQuotes should be based on the information provided as no discussions will be allowed. This solicitation is being made under FAR 12.201-1 Simplified Procedures.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Phone calls with questions will not be accepted.\n\nPoint of Contact\nCatherine Fernadez, Contract Specialist, Catherine.fernandezpedernera@va.gov.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26227Q0022","place_of_performance":{"zip":"92357","city":{"name":"Loma Linda"},"state":{"name":"CA"},"street":"VA Loma Linda Healthcare System 11201 Benton Street","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H365"},{"dates":{"posted":"2026-11-02","posted_at":"2026-11-02T18:46:35.906Z","created_at":"2026-11-02T18:46:33.582Z","modified_at":"2026-11-02T18:46:35.906Z","response_deadline":{"raw":"2026-11-09T10:00:00-08:00","utc":"2026-11-09T18:00:00Z","date":"2026-11-09","time":"10:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1c061ac1bdf148e19982bb5f68914c1c/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-08","archive_type":"auto_custom"},"history":[{"index":2,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T18:46:35.906Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1c061ac1bdf148e19982bb5f68914c1c","solicitation_number":"36C26227Q0022","parent_opportunity_id":"74391079a7f54655986d2066b40ef3f9"},{"index":1,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T20:48:13.709Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"74391079a7f54655986d2066b40ef3f9","solicitation_number":"36C26227Q0022","related_opportunity_id":"f2dd10e4902448de9bbde5be77c31a07"}],"contacts":[{"name":"Catherine Fernandez","role":"primary","email":"Catherine.fernandezpedernera@va.gov","phone":"(480)-466-7937","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"1c061ac1bdf148e19982bb5f68914c1c","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"74391079a7f54655986d2066b40ef3f9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-03T06:36:59.477495307Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"52d45175f19247f6f95471634d5142fe6ab8a6e9fcd4b3e29041a18dd9acf98f","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-11-03T04:48:34.968936277Z"},"description":{"html":"36C26227Q0022\n\n***The purpose of this amendment is to change the time of the site visit from 11:00 AM PST to 1:00 PM PST. (the date has not changed)\n\nSite visit: Site visit will be conducted by the COR Raymond Stockman,Â Raymond.Stockman@va.govÂ  909-841-1782 on November 04, 2026 at 1:00 PM (PST) and will meet at the front main lobby located at 11201 Benton St., Loma Linda CA 92357.Â  Please email Raymond Stockman.  Â RSVP with your contact information if you plan to attend the site visit.","text":"36C26227Q0022\n\n***The purpose of this amendment is to change the time of the site visit from 11:00 AM PST to 1:00 PM PST. (the date has not changed)\n\nSite visit: Site visit will be conducted by the COR Raymond Stockman,Â Raymond.Stockman@va.govÂ 909-841-1782 on November 04, 2026 at 1:00 PM (PST) and will meet at the front main lobby located at 11201 Benton St., Loma Linda CA 92357.Â Please email Raymond Stockman. Â RSVP with your contact information if you plan to attend the site visit.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26227Q0022","place_of_performance":{"zip":"92357","city":{"name":"Loma Linda"},"state":{"name":"CA"},"street":"VA Loma Linda Healthcare System 11201 Benton Street"},"product_service_code":"H365"},{"award":{"awardee":{}},"dates":{"posted":"2026-11-06","posted_at":"2026-11-06T20:50:56.783Z","created_at":"2026-11-06T20:50:55.241Z","modified_at":"2026-11-06T20:50:56.783Z","response_deadline":{"raw":"2026-11-12T10:00:00-08:00","utc":"2026-11-12T18:00:00Z","date":"2026-11-12","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cf4147a2278a475fbce5c140a7b7165e/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 12/01/2026 - 09/30/2031","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-11","archive_type":"auto_custom"},"history":[{"index":3,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 12/01/2026 - 09/30/2031","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T20:50:56.783Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf4147a2278a475fbce5c140a7b7165e","solicitation_number":"36C26227Q0022","parent_opportunity_id":"74391079a7f54655986d2066b40ef3f9"},{"index":2,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T18:46:35.906Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"1c061ac1bdf148e19982bb5f68914c1c","solicitation_number":"36C26227Q0022","parent_opportunity_id":"74391079a7f54655986d2066b40ef3f9"},{"index":1,"title":"H365--ANNUAL MEDICAL GAS TESTING POP: 11/20/2026 - 11/19/2031","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T20:48:13.709Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"74391079a7f54655986d2066b40ef3f9","solicitation_number":"36C26227Q0022","related_opportunity_id":"f2dd10e4902448de9bbde5be77c31a07"}],"contacts":[{"name":"Catherine Fernandez","role":"primary","email":"Catherine.fernandezpedernera@va.gov","phone":"(480)-466-7937","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"cf4147a2278a475fbce5c140a7b7165e","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"74391079a7f54655986d2066b40ef3f9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T09:18:50.935565485Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"57c8b2c7b6efa6082d148b072197517b-27\"","fetched_at":"2026-11-07T04:49:22.571963856Z","row_sha256":"8c52f9522b56b6d4be8d8c32bb2ec826f644ef6794802c6ccceadb912062a77a","last_modified":"2026-11-07T04:30:20Z"},"updated_at":"2026-11-11T09:18:50.935565485Z","first_seen_at":"2026-11-07T04:49:22.571963856Z"},"description":{"html":"36C26227Q0022\n\n******* The purpose of this amendment is to: \n1. Respond to questions asked regarding this solicitation. \n2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. \nBase: 12/01/2026   09/30/2027\nOY 1: 10/01/2027   09/30/2028\nOY 2: 10/01/2028   09/30/2029\nOY 3: 10/01/2029   09/30/2030\nOY 4: 10/01/2030   09/30/2031\n3. Change the response due date from 11/09/2026 to 11/12/2026. \n\nQuestions and Answers:\nQ. Can you please let me know the total number of outlets to be tested.Â \nA. 3,000 Total.\nQ. # vacuum inlets\nA. 3,000\nQ. # of medical gas system source equipment & location\nBulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center)\nQ. # of medical gas booms/columns\nA. 38, Please see attachment named  BOOM INVENTORY . \nQ. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications?\nA. ASSE 6020 and ASSE 6030 certifications are required. \nQ. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible?\nA. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached  Boom Inventory  which has the Make, Model and location.   \nQ. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment?\nA. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached  Boom Inventory .  \nQ. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? \nA. No\nQ. If this is a follow-on requirement, what is the prior contract number? \nA.  Prior Contract No. : 36C26222C0020\nQ. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? \nA. Please refer to statement of work section  V. Scope  \nQ. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? \nA. The bulk oxygen is owned and maintained by the supplier.\nQ. Are Category 3 systems, such as dental air and vacuum, in scope? \nA. Yes\nQ. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year?\nA. Only Annual.\nQ. Does each annual CLIN cover a single inspection event per year? \nA. Yes\nQ. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? \nA. Certs. Must be held by the prime and subcontractor.\nQ. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? \nA. Yes\nQ. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? \nA. Yes.\nQ. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? \nA. Yes, a brief moment.\nQ. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? \nA. Only deficiencies.\nQ. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? \nA. No. This test will only to be performed for installation,Â repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas.\nQ. When was the last annual inspection done, and when was the first inspection due under this contract? \nA. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. \nQ. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection.\nA. No particulate test performed during verification of newly installed or modified medical gas piping systems only.\n Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. \nA. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs.\nQ. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. \nA. VA requires this test to be performed annually.\nQ. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. \nA. Yes\nQ. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. \nA. Yes, if any deficiencies are found.\nQ. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. \nA. Only main Hospital and building 31 (cancer center) will be tested annually. \nQ. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI?\nA. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include \"Over and Above Repair\" to clarify that the contractor must notify the POC immediately if any repairs needs to be made.","text":"36C26227Q0022\n\n******* The purpose of this amendment is to:\n1. Respond to questions asked regarding this solicitation.\n2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026.\nBase: 12/01/2026 09/30/2027\nOY 1: 10/01/2027 09/30/2028\nOY 2: 10/01/2028 09/30/2029\nOY 3: 10/01/2029 09/30/2030\nOY 4: 10/01/2030 09/30/2031\n3. Change the response due date from 11/09/2026 to 11/12/2026.\n\nQuestions and Answers:\nQ. Can you please let me know the total number of outlets to be tested.Â\nA. 3,000 Total.\nQ. # vacuum inlets\nA. 3,000\nQ. # of medical gas system source equipment & location\nBulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center)\nQ. # of medical gas booms/columns\nA. 38, Please see attachment named BOOM INVENTORY .\nQ. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications?\nA. ASSE 6020 and ASSE 6030 certifications are required.\nQ. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible?\nA. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location.\nQ. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment?\nA. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory .\nQ. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment?\nA. No\nQ. If this is a follow-on requirement, what is the prior contract number?\nA. Prior Contract No. : 36C26222C0020\nQ. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)?\nA. Please refer to statement of work section V. Scope\nQ. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side?\nA. The bulk oxygen is owned and maintained by the supplier.\nQ. Are Category 3 systems, such as dental air and vacuum, in scope?\nA. Yes\nQ. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year?\nA. Only Annual.\nQ. Does each annual CLIN cover a single inspection event per year?\nA. Yes\nQ. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees?\nA. Certs. Must be held by the prime and subcontractor.\nQ. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing?\nA. Yes\nQ. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones?\nA. Yes.\nQ. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded?\nA. Yes, a brief moment.\nQ. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies?\nA. Only deficiencies.\nQ. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32?\nA. No. This test will only to be performed for installation,Â repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas.\nQ. When was the last annual inspection done, and when was the first inspection due under this contract?\nA. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26.\nQ. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection.\nA. No particulate test performed during verification of newly installed or modified medical gas piping systems only.\nQ. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99.\nA. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs.\nQ. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months.\nA. VA requires this test to be performed annually.\nQ. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot.\nA. Yes\nQ. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs.\nA. Yes, if any deficiencies are found.\nQ. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm.\nA. Only main Hospital and building 31 (cancer center) will be tested annually.\nQ. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI?\nA. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include \"Over and Above Repair\" to clarify that the contractor must notify the POC immediately if any repairs needs to be made.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26227Q0022","place_of_performance":{"zip":"92357","city":{"name":"Loma Linda"},"state":{"name":"CA"},"street":"VA Loma Linda Healthcare System 11201 Benton Street","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"H365"}],"due_at":"2026-11-12T18:00:00Z","due_date":"2026-11-12","closes_at":"2026-11-12T18:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-07T04:54:53.607561Z","principal_notice_id":"cf4147a2278a475fbce5c140a7b7165e","description":{"text":"36C26227Q0022\n\n******* The purpose of this amendment is to:\n1. Respond to questions asked regarding this solicitation.\n2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026.\nBase: 12/01/2026 09/30/2027\nOY 1: 10/01/2027 09/30/2028\nOY 2: 10/01/2028 09/30/2029\nOY 3: 10/01/2029 09/30/2030\nOY 4: 10/01/2030 09/30/2031\n3. Change the response due date from 11/09/2026 to 11/12/2026.\n\nQuestions and Answers:\nQ. Can you please let me know the total number of outlets to be tested.Â\nA. 3,000 Total.\nQ. # vacuum inlets\nA. 3,000\nQ. # of medical gas system source equipment & location\nBulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center)\nQ. # of medical gas booms/columns\nA. 38, Please see attachment named BOOM INVENTORY .\nQ. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications?\nA. ASSE 6020 and ASSE 6030 certifications are required.\nQ. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible?\nA. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location.\nQ. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment?\nA. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory .\nQ. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment?\nA. No\nQ. If this is a follow-on requirement, what is the prior contract number?\nA. Prior Contract No. : 36C26222C0020\nQ. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)?\nA. Please refer to statement of work section V. Scope\nQ. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side?\nA. The bulk oxygen is owned and maintained by the supplier.\nQ. Are Category 3 systems, such as dental air and vacuum, in scope?\nA. Yes\nQ. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year?\nA. Only Annual.\nQ. Does each annual CLIN cover a single inspection event per year?\nA. Yes\nQ. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees?\nA. Certs. Must be held by the prime and subcontractor.\nQ. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing?\nA. Yes\nQ. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones?\nA. Yes.\nQ. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded?\nA. Yes, a brief moment.\nQ. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies?\nA. Only deficiencies.\nQ. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32?\nA. No. This test will only to be performed for installation,Â repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas.\nQ. When was the last annual inspection done, and when was the first inspection due under this contract?\nA. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26.\nQ. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection.\nA. No particulate test performed during verification of newly installed or modified medical gas piping systems only.\nQ. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99.\nA. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs.\nQ. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months.\nA. VA requires this test to be performed annually.\nQ. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot.\nA. Yes\nQ. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs.\nA. Yes, if any deficiencies are found.\nQ. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm.\nA. Only main Hospital and building 31 (cancer center) will be tested annually.\nQ. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI?\nA. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include \"Over and Above Repair\" to clarify that the contractor must notify the POC immediately if any repairs needs to be made.","html":"36C26227Q0022\n\n******* The purpose of this amendment is to: \n1. Respond to questions asked regarding this solicitation. \n2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. \nBase: 12/01/2026   09/30/2027\nOY 1: 10/01/2027   09/30/2028\nOY 2: 10/01/2028   09/30/2029\nOY 3: 10/01/2029   09/30/2030\nOY 4: 10/01/2030   09/30/2031\n3. Change the response due date from 11/09/2026 to 11/12/2026. \n\nQuestions and Answers:\nQ. Can you please let me know the total number of outlets to be tested.Â \nA. 3,000 Total.\nQ. # vacuum inlets\nA. 3,000\nQ. # of medical gas system source equipment & location\nBulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center)\nQ. # of medical gas booms/columns\nA. 38, Please see attachment named  BOOM INVENTORY . \nQ. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications?\nA. ASSE 6020 and ASSE 6030 certifications are required. \nQ. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible?\nA. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached  Boom Inventory  which has the Make, Model and location.   \nQ. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment?\nA. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached  Boom Inventory .  \nQ. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? \nA. No\nQ. If this is a follow-on requirement, what is the prior contract number? \nA.  Prior Contract No. : 36C26222C0020\nQ. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? \nA. Please refer to statement of work section  V. Scope  \nQ. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? \nA. The bulk oxygen is owned and maintained by the supplier.\nQ. Are Category 3 systems, such as dental air and vacuum, in scope? \nA. Yes\nQ. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year?\nA. Only Annual.\nQ. Does each annual CLIN cover a single inspection event per year? \nA. Yes\nQ. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? \nA. Certs. Must be held by the prime and subcontractor.\nQ. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? \nA. Yes\nQ. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? \nA. Yes.\nQ. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? \nA. Yes, a brief moment.\nQ. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? \nA. Only deficiencies.\nQ. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? \nA. No. This test will only to be performed for installation,Â repair, or modification of any medical gas piping systems, Building 29, 30 has no medical gas.\nQ. When was the last annual inspection done, and when was the first inspection due under this contract? \nA. The last inspection was completed on 11/24/25 - 2026 inspection needs to be completed before 12/21/26. \nQ. Oxygen particulate analysis: This filter test is typically performed as a pre-test during construction projects under NFPA 99. The results would generally be expected to remain unchanged unless the pipeline is breached during construction. Please confirm whether this test is required as part of the annual inspection.\nA. No particulate test performed during verification of newly installed or modified medical gas piping systems only.\n Q. ASSE 6010 certification: Please confirm whether ASSE 6010 certification is required. Our understanding is that this is a medical gas installer certification, rather than an annual inspection requirement under NFPA 99. \nA. No, only if repairs need to be performed, contractor shall be 6010 certified to make repairs.\nQ. Boom testing frequency: Please confirm whether boom testing is required annually. Our understanding is that NFPA 99 recommends testing every 18 months. \nA. VA requires this test to be performed annually.\nQ. Boom testing scope: Please confirm whether the testing includes disassembly of the booms to inspect for leaks and dry rot. \nA. Yes\nQ. Boom testing report: Please confirm whether the detailed report should include photographs of disassembled booms and a comprehensive list of recommended repairs. \nA. Yes, if any deficiencies are found.\nQ. Building confirmation: Mr. Stockman indicated that Eye Clinic Building 32 and Audiology Building 30 should be excluded from the proposal. Please confirm. \nA. Only main Hospital and building 31 (cancer center) will be tested annually. \nQ. Could you please clarify what repair work, if any, must be included in the annual fixed price? Specifically, should the contractor include any routine repairs or corrective maintenance, or will all repairs, replacement parts, and installation services be treated as separately authorized work under Section VI?\nA. This solicitation is only for Inspection, not for repairs. In the Statement of Work (Section VII) we have to include \"Over and Above Repair\" to clarify that the contractor must notify the POC immediately if any repairs needs to be made.","origin":"detail"},"contacts":[{"name":"Catherine Fernandez","role":"primary","email":"Catherine.fernandezpedernera@va.gov","phone":"(480)-466-7937","title":"Contract Specialist"}],"place_of_performance":{"zip":"92357","city":{"name":"Loma Linda"},"state":{"name":"CA"},"street":"VA Loma Linda Healthcare System 11201 Benton Street","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"naics_codes":["541380"],"award":{"awardee":{}},"attachments":[{"resource_id":"fde168f5e9b044729fffdf2d8e6b5a44","name":"36C26227Q0022.docx","kind":"file","mime_type":".docx","size_bytes":39381,"posted_at":"2026-09-24T00:40:49.832Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fde168f5e9b044729fffdf2d8e6b5a44/download","mirrored":false},{"resource_id":"aa7d3fd55a5b4860a44cd7439b4a19b6","name":"36C26227Q0022_1.docx","kind":"file","mime_type":".docx","size_bytes":73081,"posted_at":"2026-10-30T20:48:13.709Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/aa7d3fd55a5b4860a44cd7439b4a19b6/download","mirrored":false},{"resource_id":"bfaa2593a8104dd6bc4c5263104276b5","name":"Price Cost Schedule.docx","kind":"file","mime_type":".docx","size_bytes":24667,"posted_at":"2026-10-30T20:48:13.709Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/bfaa2593a8104dd6bc4c5263104276b5/download","mirrored":false},{"resource_id":"e7674e7068f440db87ca0175e74d968e","name":"36C26227Q0022_2.docx","kind":"file","mime_type":".docx","size_bytes":25907,"posted_at":"2026-11-02T18:46:35.906Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e7674e7068f440db87ca0175e74d968e/download","mirrored":false},{"resource_id":"ca312e8107c94844a664f9edd4c484b1","name":"36C26227Q0022_3.docx","kind":"file","mime_type":".docx","size_bytes":29647,"posted_at":"2026-11-06T20:50:56.783Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ca312e8107c94844a664f9edd4c484b1/download","mirrored":false},{"resource_id":"078bec02d1b34e2583d42ce68b5a6698","name":"BOOM INVENTORY.xlsx","kind":"file","mime_type":".xlsx","size_bytes":13554,"posted_at":"2026-11-06T20:50:56.783Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/078bec02d1b34e2583d42ce68b5a6698/download","mirrored":false},{"resource_id":"05ee161b146c40b2b4af26d1c9950bdc","name":"Price Cost Schedule - Revised.docx","kind":"file","mime_type":".docx","size_bytes":24849,"posted_at":"2026-11-06T20:50:56.783Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/05ee161b146c40b2b4af26d1c9950bdc/download","mirrored":false}],"awards":[],"related":[{"key":"36C26227Q0085","latest_notice_id":"cdde3a94bda84b199f9d3db72af657a6","title":"S215--SDVOSB Furniture Installation Labor Storage - Base Plus Four Option Years | POP: (12/31/2026 - 12/30/2031) |","solicitation_number":"36C26227Q0085","notice_type":"o","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-23","notices":4,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"493190","psc":"S215","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C26227Q0079","latest_notice_id":"00646e7746494ab38ce53bbe9f7e0f59","title":"W065--RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT","solicitation_number":"36C26227Q0079","notice_type":"k","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-26T20:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"532490","psc":"W065","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0139","latest_notice_id":"156fef93406e495486eb1d4e805bb675","title":"6515--PYXIS IV PREP","solicitation_number":"36C26227Q0139","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541519","psc":"6515","set_aside":"SDVOSBC","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26227Q0146","latest_notice_id":"e2fc7d7b106d4b448a5b57cba568ddb4","title":"J041--KITCHEN HOOD PMIR - Base +4 ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0146","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"561790","psc":"J041","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T08:15:06.508374Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open":[{"key":"FA442727Q1009","latest_notice_id":"182e0fcc027e4ae0b87bb2e52b42c8d1","title":"Hot Sticks and Gloves Testing Services, Travis AFB","solicitation_number":"FA442727Q1009","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4427","office_name":"FA4427 60 CONS LGC","naics":"541380","psc":"H259","set_aside":"SBA","state":"CA","county":"06095","county_name":"Solano County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Travis Air Force Base","site_key":"travis-air-force-base-ca","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SP330027Q0011","latest_notice_id":"45066985ccdb460a8380113ba1f54d04","title":"Cross Connection Hazard Assessment","solicitation_number":"SP330027Q0011","notice_type":"k","first_type":"k","first_posted":"2026-11-06","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-14T17:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP3300","office_name":"DLA DISTRIBUTION","naics":"541380","psc":"F107","set_aside":"SBA","state":"CA","county":"06077","county_name":"San Joaquin County","city":"0680238","city_name":"Tracy","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":34,"indexable":true}