{"canonical":"https://sealedbidder.com/opportunities/36c26226q1387","key":"36C26226Q1387","url":"https://sealedbidder.com/opportunities/36c26226q1387","title":"J035--ELEVATOR INSPECTION SERVICE","solicitation_number":"36C26226Q1387","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-27T20:00:00Z","first_posted":"2026-08-20","last_posted":"2026-08-20","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"811310","psc":"J035","set_aside":"SDVOSBC","place_state":"CA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"06073","place_county_name":"San Diego County","place_city":"0666000","place_city_name":"San Diego","winner":"VETERAN ELEVATOR INSPECTION SERVICES, LLC","award_amount":null,"publications":[{"notice_id":"e10b8c50725944f889771ac6d54d49ae","title":"J035--ELEVATOR INSPECTION SERVICE","solicitation_number":"36C26226Q1387","notice_type":"k","base_type":"k","posted":"2026-08-20","posted_at":"2026-08-20T21:32:05.511Z","due_at":"2026-08-27T20:00:00Z","due_date":"2026-08-27","cancelled":false,"archived":true,"archive_date":"2026-10-26","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e10b8c50725944f889771ac6d54d49ae/view","enriched":true,"history":[{"index":1,"title":"J035--ELEVATOR INSPECTION SERVICE","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-20T21:32:05.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"e10b8c50725944f889771ac6d54d49ae","solicitation_number":"36C26226Q1387"}]}],"latest_notice_id":"e10b8c50725944f889771ac6d54d49ae","first_type":"k","notices":[{"dates":{"posted":"2026-08-20","posted_at":"2026-08-20T21:32:05.511Z","created_at":"2026-08-20T21:32:04.323Z","modified_at":"2026-08-20T21:32:05.511Z","response_deadline":{"raw":"2026-08-27T13:00:00-07:00","utc":"2026-08-27T20:00:00Z","date":"2026-08-27","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e10b8c50725944f889771ac6d54d49ae/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J035--ELEVATOR INSPECTION SERVICE","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-26","archive_type":"auto_custom"},"history":[{"index":1,"title":"J035--ELEVATOR INSPECTION SERVICE","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-20T21:32:05.511Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"e10b8c50725944f889771ac6d54d49ae","solicitation_number":"36C26226Q1387"}],"contacts":[{"name":"Stephanie Naron","role":"primary","email":"stephanie.naron@va.gov","phone":"520-792-1450 14387","title":"CONTRACT SPECIALIST"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"e10b8c50725944f889771ac6d54d49ae","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"e10b8c50725944f889771ac6d54d49ae","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-18T00:16:06.485899837Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"59a41ae88609c74dd915ff91b73bb745a97a49a2497a89b5ad8ddb74b9e51a3c","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"2\n\nEffective Date:  01/15/2026\nRevision: 03\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-06. \n\nThis solicitation is set aside for SDVOSB business concerns.\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Phone calls with questions will not be accepted.\nPoint of Contact\nStephanie Naron, Contract Specialist, Stephanie.Naron@va.gov. \n\nStatement Of Work\n\nCONTRACT TITLE:\nElevator Inspections & Certification\n\nPLACE OF PERFORMANCES:\nVA San Diego Healthcare System\n3350 La Jolla Village Dr.\nSan Diego, CA 92161\n\nPERIOD OF PERFORMANCE:\nOne base year and four (4) option years.\n\nCONTRACT TYPE:\nFirm Fixed Price\n\nBACKGROUND:\nThis contract is for semi-annual inspections and maintenance review, annual/CAT 1 inspections, and safety testing of Government owned Vertical Transportation Units (VTUs) at the VA San Diego Healthcare System, to include elevators, dumbwaiters, wheelchair lifts, and cart lifts. All VTUs additionally require a 5-year/CAT 5 elevator test.\n\nGENERAL REQUIREMENTS:\n6.1. The Contractor shall furnish all equipment, expertise, incidentals, labor, materials, parts, supervision, supplies, tools, transportation, and qualified personnel required and necessary to conduct inspection services in accordance/compliance with manufacturer guidelines/recommendations, current code(s), directives, regulations, Joint Commission, and industry standards at VA San Deigo Healthcare System.\n6.2. Contractor shall check in with Electric Shop Supervisor or appointed prior to performing any work.\n6.3. Contractor and employees shall be issued temporary ID badges from the VA Police Department that must always be worn while on station.\n6.4. All damages incurred during the performance of this scope of work will be repaired by the Contractor at no cost to the VA.\n6.5. Contractor is responsible for providing and utilizing all OSHA regulated Personal Protective Equipment (PPE) while performing all inspection and testing requirements.\n6.6. Contractor shall follow all VA regulations and provide the means to meet these regulations.\n\nSPECIFIC REQUIREMENTS: \nThe Contractor shall provide independent elevator inspection services that include inspection, verification, and certification of annual and semi-annual inspection, semi-annual maintenance reviews, safety tests, and 5-year load testing to ensure reliable and continuous safe operation of Government owned VTU' s. A list of all VTUs  can be found in SUPPLEMENT 1 - MASTER ELEVATOR INVENTORY (See Section 8). The list is subject to change throughout the performance of the contract and all parties involved will be notified of any changes within five (5) business days.\n7.1. Prior to performing independent inspection services, The Contractor shall provide notification to the COR and the Government Elevator Maintenance and Repair Contractor of the dates of proposed services. The notification should reach the Government and Elevator Maintenance and Repair Contractor at least fifteen (15) calendar days prior to the proposed inspection. The notification shall be in writing and shall include the proposed inspection and testing dates, estimated time of arrival and completion of services, name and local contact information of the technician performing the services.\n7.2. Inspections and tests shall be completed in accordance with the most current edition of the American Society of Mechanical Engineers (ASME) 17.1 Safety Code for Elevators and Escalators, ASME 17 .2 Guide for Inspection of Elevators, Escalators, and Moving Walks and ASME 17.3 Safety Code for Existing Elevators and Escalators. In addition, the Contractor shall be aware of and adhere to all applicable Federal, State, County and City, rules, recommendations, regulations, guidelines and laws pertaining to the execution of all inspection services.\n7.3. The Contractor shall provide the necessary labels, metal tags or other tagging and labeling according to requirements.\n7.4. The Contractor is responsible for ensuring services are provided by qualified and competent personnel for all Elevator Inspections pertinent to this contract. At a minimum, contractor personnel shall maintain a CURRENT ASME QEI 1 Certification.\n\nINVENTORY: \nThe Contractor responsible for providing required inspection for all VA San Diego Medical Center VTU s according to SUPPLEMENT 1 - MASTER ELEVATOR INVENTORY:\nBldg 1\nP1, P2, P3, P4, P5, P6, S1, S2, S3, S4, Research, dumbwaiter\n\n12\nMRI\nP1\n\n1\nBldg 11\nP1, P2, P3, P4, S1\n\n5\nBldg 26\nP1, P2, P5, P6, S1, S2, S3, S4\n\n8\nBldg 27\nP1, P2\n\n2\nBldg 28\nPG1\n\n1\nBldg 31\nPG2\n\n1\nBldg 32\nPG1, PG2, PG3, PG4\n\n4\nTotal\nÂ \n\n34\n\nDOCUMENTATION AND REPORTS: \nWithin ten (10) business days of the completion of an inspection or test, the Contractor shall complete and submit a separate written narrative report for each VTU inspected. The report shall include the date and time of the inspection or test, the location, the equipment, the type of service performed, actual hours spent performing requested service, and the name of the technician performing the service. The Contractor shall submit two (2) copies of each report in written format and one (1) copy in digital format to the designated COR of the facility inspected/tested, and the Elevator Maintenance Contractor of the facility inspected/tested on VA supplied forms.\n9.1. The report shall identify each VTU inspected or tested by building, serial and unit number. The report shall describe any needed adjustments, repairs, worn parts and other items required or recommended for keeping the-VTU operating safely. The report shall make specific reference to safety code violations, including the title of the code being cited, the section or clause which refers to the specific violation and other reference that will assist the COR and Elevator Maintenance and Repair contractor in making necessary repairs or adjustments.\n9.2. The report shall adhere to the reporting requirements of the publications listed in VA supplied forms and describe the general condition; state of repair and cleanliness of each VTU. The report shall describe the state of the surrounding pits, access, lighting, machine rooms, cabs and landings. In addition, the report shall include any Contractor recommendation(s) that will assist the Government in maintaining the equipment in optimum operating condition.\n9.3. The contractor shall fully complete and submit with report one (1) digital and two (2) paper copies of the most current version of SUPPLEMENT 2 - Checklist for Inspection of Electric Elevators and SUPPLEMENT 3 - Five (5) Year Full Load Test Inspection In lieu of the ASME approved forms listed above.\n9.4. During an inspection or test if the contractor discovers a defective VTU that requires immediate repair or service, he/she shall notify the COR and the Elevator Maintenance and Repair Contractor prior to leaving the facility where the defective VTU is located. The Contractor shall describe the location of the defective VTU, repairs or adjustment needed, and if the VTU can or should remain in service. Contractor shall follow-up in 24 hours with a written report of the defective VTU and describes the action taken to report needed repairs.\n\nCONTRACTOR'S QUALIFICATIONS: \nContractor's personnel performing on this Contract must be fully qualified competent service technician(s). \"Fully qualified\" is defined as meeting the requirements of the most current edition of ASME QEI-1 for the Qualification of Elevator Inspectors. The Contractor will be required to update competency information throughout the life of the contract as changes occur. The Contractor must provide for Government approval credentials of each service technician. Credentials must be provided prior to the employee being assigned services responsibilities on Government equipment listed herein. Contractors shall provide proof and adequacy of past performance history, references, and required qualifications.\n\nAPPLICABLE DOCUMENTS, STANDARDS, LAWS AND/OR REGULATIONS: \nThe following are a list of various applicable standards, policies, regulations, and/or governing bodies. This list isÂ· not an all-inclusive list, therefore it is the responsibility of the contractor to ensure all applicable standards, policies, regulations, and/or governing bodies not listed here are adhere to. Furthermore, contractor is responsible to adhere to all current addition of applicable standards, policies, regulations, and/or governing bodies.\n11.1. The American Society of Mechanical Engineers (ASME), www.asme.org\n11.2. ASME -A17 -Elevators and Escalators\n11.3. ASME -A17 .1 - Safety Code for Elevators and Escalators\n11.4. ASME-A17 .2 -Guide for Inspection of Elevators, Escalators, and Moving W a1ks\n11.5. ASME-A17.3 -Safety Code for Existing Elevators and Escalators (Includes Requirements for Electric and Hydraulic Elevators and Escalators)\n11.6. ASME-A18-.1-Safety Standards for Platform Lifts and Stairway Chairlifts\n11.7. ASME-QEI-1-Standard for the Qualification of Elevator Inspectors\n11.8. National Association of Elevator Safety Authorities International (NAESAI), www.naesai.org\n11.9. NFPA 70-National Electrical Code\n11.10. NFPA 70E -Standard for Electrical Safety in the Workplace\n\nSAFETY REQUIREMENTS:\nAll personnel employed by the Contractor in the performance of this contract, or any representative of the Contractor entering on VASDHS shall comply with applicable Federal, State, and VA safety and fire regulations and codes, which are in effect during the performance period of the contract.\nContractor shall perform work in strict accordance with existing relevant, accredited standards and codes to minimize the possibility of injury to personnel, or damage to Government equipment.  Every effort shall be made to safeguard human life and property.  \nContractor shall comply with all applicable Federal, State, and local requirements regarding workers  health and safety. The requirements include, but are not limited to, those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR), Parts 1910 and 1926, NFPA 70E, Article 130.7 29 CFR 1910.132(d)(1)(iii), 29CFR1910.137\nContractor shall provide all necessary tools, and Personal Protective Equipment (PPE) to perform the work safely, effectively, and timely. \nThe VAMC San Diego building 1, main building, contains asbestos. Any worker entering these asbestos containing areas must have an asbestos certification of no less than 16 hours and a valid fit test certification. Certifications must be presented to the VA project manager before any work in an asbestos area may begin. \n\nCHANGES:\nThe awarded Contractor is advised that only the Contracting Officer, acting within the scope of the contract has the authority to make changes which affect the contract in terms of quality, quantity, price or delivery.\n\nIn the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered to have been made without authority and no adjustment shall be made in the contract price to cover any increase in costs incurred as a result thereof.\n\nVA POLICY:\nPossession of weapons is prohibited. Enclosed containers, including tool kits, are subject to search. Violations of VA regulations may result in citations answerable in the United States (Federal) District Court.\n\nPARKING POLICY:\nIt is the responsibility of Contractor personnel to park only in designated parking areas.  Parking information is available from the VA Police. The VA shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nIDENTIFICATION BADGES:\nAll Contractor personnel are required to wear identification (I.D.) badges during the \nentire time they are on the VA Healthcare System grounds. I.D. badges must have an identification picture and shall state the name of the individual and the company represented.\n\nSMOKING POLICY:\nSmoking is not permitted within the VA Healthcare System facilities campus.\n\nNORMAL WORKING HOURS:\nNormal hours of operation are Monday through Friday from 08:00 am to 4:30 pm Pacific time. All work is expected to be performed generally during normal hours of coverage unless requested or approved by the COR or his/her designee.\n\nBefore commencement of work, the Contractor shall confer with the VA COR and Contracting Office to agree on a sequence of procedures; means of access to premises and building. All work performed, to include delivery of materials and equipment, shall be made with minimal interference to Government operations and personnel.\n\nWork performed outside the normal hours of coverage must be approved by the COR or his/her designee.\n\nOVERTIME AND NATIONAL HOLIDAYS:\nAny overtime or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government.\n\nThe Contractor is not required to provide service on the following U.S. Government holidays nor shall the Contractor be paid for these days:\n\nNew Year s Day\nJanuary 1\nMartin Luther King  s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day \nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day \nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day \nSecond Monday in October\nVeterans Day \nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25","text":"2\n\nEffective Date: 01/15/2026\nRevision: 03\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-06.\n\nThis solicitation is set aside for SDVOSB business concerns.\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Phone calls with questions will not be accepted.\nPoint of Contact\nStephanie Naron, Contract Specialist, Stephanie.Naron@va.gov.\n\nStatement Of Work\n\nCONTRACT TITLE:\nElevator Inspections & Certification\n\nPLACE OF PERFORMANCES:\nVA San Diego Healthcare System\n3350 La Jolla Village Dr.\nSan Diego, CA 92161\n\nPERIOD OF PERFORMANCE:\nOne base year and four (4) option years.\n\nCONTRACT TYPE:\nFirm Fixed Price\n\nBACKGROUND:\nThis contract is for semi-annual inspections and maintenance review, annual/CAT 1 inspections, and safety testing of Government owned Vertical Transportation Units (VTUs) at the VA San Diego Healthcare System, to include elevators, dumbwaiters, wheelchair lifts, and cart lifts. All VTUs additionally require a 5-year/CAT 5 elevator test.\n\nGENERAL REQUIREMENTS:\n6.1. The Contractor shall furnish all equipment, expertise, incidentals, labor, materials, parts, supervision, supplies, tools, transportation, and qualified personnel required and necessary to conduct inspection services in accordance/compliance with manufacturer guidelines/recommendations, current code(s), directives, regulations, Joint Commission, and industry standards at VA San Deigo Healthcare System.\n6.2. Contractor shall check in with Electric Shop Supervisor or appointed prior to performing any work.\n6.3. Contractor and employees shall be issued temporary ID badges from the VA Police Department that must always be worn while on station.\n6.4. All damages incurred during the performance of this scope of work will be repaired by the Contractor at no cost to the VA.\n6.5. Contractor is responsible for providing and utilizing all OSHA regulated Personal Protective Equipment (PPE) while performing all inspection and testing requirements.\n6.6. Contractor shall follow all VA regulations and provide the means to meet these regulations.\n\nSPECIFIC REQUIREMENTS:\nThe Contractor shall provide independent elevator inspection services that include inspection, verification, and certification of annual and semi-annual inspection, semi-annual maintenance reviews, safety tests, and 5-year load testing to ensure reliable and continuous safe operation of Government owned VTU' s. A list of all VTUs can be found in SUPPLEMENT 1 - MASTER ELEVATOR INVENTORY (See Section 8). The list is subject to change throughout the performance of the contract and all parties involved will be notified of any changes within five (5) business days.\n7.1. Prior to performing independent inspection services, The Contractor shall provide notification to the COR and the Government Elevator Maintenance and Repair Contractor of the dates of proposed services. The notification should reach the Government and Elevator Maintenance and Repair Contractor at least fifteen (15) calendar days prior to the proposed inspection. The notification shall be in writing and shall include the proposed inspection and testing dates, estimated time of arrival and completion of services, name and local contact information of the technician performing the services.\n7.2. Inspections and tests shall be completed in accordance with the most current edition of the American Society of Mechanical Engineers (ASME) 17.1 Safety Code for Elevators and Escalators, ASME 17 .2 Guide for Inspection of Elevators, Escalators, and Moving Walks and ASME 17.3 Safety Code for Existing Elevators and Escalators. In addition, the Contractor shall be aware of and adhere to all applicable Federal, State, County and City, rules, recommendations, regulations, guidelines and laws pertaining to the execution of all inspection services.\n7.3. The Contractor shall provide the necessary labels, metal tags or other tagging and labeling according to requirements.\n7.4. The Contractor is responsible for ensuring services are provided by qualified and competent personnel for all Elevator Inspections pertinent to this contract. At a minimum, contractor personnel shall maintain a CURRENT ASME QEI 1 Certification.\n\nINVENTORY:\nThe Contractor responsible for providing required inspection for all VA San Diego Medical Center VTU s according to SUPPLEMENT 1 - MASTER ELEVATOR INVENTORY:\nBldg 1\nP1, P2, P3, P4, P5, P6, S1, S2, S3, S4, Research, dumbwaiter\n\n12\nMRI\nP1\n\n1\nBldg 11\nP1, P2, P3, P4, S1\n\n5\nBldg 26\nP1, P2, P5, P6, S1, S2, S3, S4\n\n8\nBldg 27\nP1, P2\n\n2\nBldg 28\nPG1\n\n1\nBldg 31\nPG2\n\n1\nBldg 32\nPG1, PG2, PG3, PG4\n\n4\nTotal\nÂ\n\n34\n\nDOCUMENTATION AND REPORTS:\nWithin ten (10) business days of the completion of an inspection or test, the Contractor shall complete and submit a separate written narrative report for each VTU inspected. The report shall include the date and time of the inspection or test, the location, the equipment, the type of service performed, actual hours spent performing requested service, and the name of the technician performing the service. The Contractor shall submit two (2) copies of each report in written format and one (1) copy in digital format to the designated COR of the facility inspected/tested, and the Elevator Maintenance Contractor of the facility inspected/tested on VA supplied forms.\n9.1. The report shall identify each VTU inspected or tested by building, serial and unit number. The report shall describe any needed adjustments, repairs, worn parts and other items required or recommended for keeping the-VTU operating safely. The report shall make specific reference to safety code violations, including the title of the code being cited, the section or clause which refers to the specific violation and other reference that will assist the COR and Elevator Maintenance and Repair contractor in making necessary repairs or adjustments.\n9.2. The report shall adhere to the reporting requirements of the publications listed in VA supplied forms and describe the general condition; state of repair and cleanliness of each VTU. The report shall describe the state of the surrounding pits, access, lighting, machine rooms, cabs and landings. In addition, the report shall include any Contractor recommendation(s) that will assist the Government in maintaining the equipment in optimum operating condition.\n9.3. The contractor shall fully complete and submit with report one (1) digital and two (2) paper copies of the most current version of SUPPLEMENT 2 - Checklist for Inspection of Electric Elevators and SUPPLEMENT 3 - Five (5) Year Full Load Test Inspection In lieu of the ASME approved forms listed above.\n9.4. During an inspection or test if the contractor discovers a defective VTU that requires immediate repair or service, he/she shall notify the COR and the Elevator Maintenance and Repair Contractor prior to leaving the facility where the defective VTU is located. The Contractor shall describe the location of the defective VTU, repairs or adjustment needed, and if the VTU can or should remain in service. Contractor shall follow-up in 24 hours with a written report of the defective VTU and describes the action taken to report needed repairs.\n\nCONTRACTOR'S QUALIFICATIONS:\nContractor's personnel performing on this Contract must be fully qualified competent service technician(s). \"Fully qualified\" is defined as meeting the requirements of the most current edition of ASME QEI-1 for the Qualification of Elevator Inspectors. The Contractor will be required to update competency information throughout the life of the contract as changes occur. The Contractor must provide for Government approval credentials of each service technician. Credentials must be provided prior to the employee being assigned services responsibilities on Government equipment listed herein. Contractors shall provide proof and adequacy of past performance history, references, and required qualifications.\n\nAPPLICABLE DOCUMENTS, STANDARDS, LAWS AND/OR REGULATIONS:\nThe following are a list of various applicable standards, policies, regulations, and/or governing bodies. This list isÂ· not an all-inclusive list, therefore it is the responsibility of the contractor to ensure all applicable standards, policies, regulations, and/or governing bodies not listed here are adhere to. Furthermore, contractor is responsible to adhere to all current addition of applicable standards, policies, regulations, and/or governing bodies.\n11.1. The American Society of Mechanical Engineers (ASME), www.asme.org\n11.2. ASME -A17 -Elevators and Escalators\n11.3. ASME -A17 .1 - Safety Code for Elevators and Escalators\n11.4. ASME-A17 .2 -Guide for Inspection of Elevators, Escalators, and Moving W a1ks\n11.5. ASME-A17.3 -Safety Code for Existing Elevators and Escalators (Includes Requirements for Electric and Hydraulic Elevators and Escalators)\n11.6. ASME-A18-.1-Safety Standards for Platform Lifts and Stairway Chairlifts\n11.7. ASME-QEI-1-Standard for the Qualification of Elevator Inspectors\n11.8. National Association of Elevator Safety Authorities International (NAESAI), www.naesai.org\n11.9. NFPA 70-National Electrical Code\n11.10. NFPA 70E -Standard for Electrical Safety in the Workplace\n\nSAFETY REQUIREMENTS:\nAll personnel employed by the Contractor in the performance of this contract, or any representative of the Contractor entering on VASDHS shall comply with applicable Federal, State, and VA safety and fire regulations and codes, which are in effect during the performance period of the contract.\nContractor shall perform work in strict accordance with existing relevant, accredited standards and codes to minimize the possibility of injury to personnel, or damage to Government equipment. Every effort shall be made to safeguard human life and property.\nContractor shall comply with all applicable Federal, State, and local requirements regarding workers health and safety. The requirements include, but are not limited to, those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR), Parts 1910 and 1926, NFPA 70E, Article 130.7 29 CFR 1910.132(d)(1)(iii), 29CFR1910.137\nContractor shall provide all necessary tools, and Personal Protective Equipment (PPE) to perform the work safely, effectively, and timely.\nThe VAMC San Diego building 1, main building, contains asbestos. Any worker entering these asbestos containing areas must have an asbestos certification of no less than 16 hours and a valid fit test certification. Certifications must be presented to the VA project manager before any work in an asbestos area may begin.\n\nCHANGES:\nThe awarded Contractor is advised that only the Contracting Officer, acting within the scope of the contract has the authority to make changes which affect the contract in terms of quality, quantity, price or delivery.\n\nIn the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered to have been made without authority and no adjustment shall be made in the contract price to cover any increase in costs incurred as a result thereof.\n\nVA POLICY:\nPossession of weapons is prohibited. Enclosed containers, including tool kits, are subject to search. Violations of VA regulations may result in citations answerable in the United States (Federal) District Court.\n\nPARKING POLICY:\nIt is the responsibility of Contractor personnel to park only in designated parking areas. Parking information is available from the VA Police. The VA shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nIDENTIFICATION BADGES:\nAll Contractor personnel are required to wear identification (I.D.) badges during the\nentire time they are on the VA Healthcare System grounds. I.D. badges must have an identification picture and shall state the name of the individual and the company represented.\n\nSMOKING POLICY:\nSmoking is not permitted within the VA Healthcare System facilities campus.\n\nNORMAL WORKING HOURS:\nNormal hours of operation are Monday through Friday from 08:00 am to 4:30 pm Pacific time. All work is expected to be performed generally during normal hours of coverage unless requested or approved by the COR or his/her designee.\n\nBefore commencement of work, the Contractor shall confer with the VA COR and Contracting Office to agree on a sequence of procedures; means of access to premises and building. All work performed, to include delivery of materials and equipment, shall be made with minimal interference to Government operations and personnel.\n\nWork performed outside the normal hours of coverage must be approved by the COR or his/her designee.\n\nOVERTIME AND NATIONAL HOLIDAYS:\nAny overtime or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government.\n\nThe Contractor is not required to provide service on the following U.S. Government holidays nor shall the Contractor be paid for these days:\n\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeterans Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26226Q1387","place_of_performance":{"zip":"92161-0002","city":{"name":"San Diego"},"street":"Jennifer Moreno Department of Veterans Affairs Med Department of Veterans Affairs 3350 La Jolla Village Drive"},"product_service_code":"J035"}],"due_at":"2026-08-27T20:00:00Z","due_date":"2026-08-27","closes_at":"2026-08-27T20:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":null,"state_source":null,"state_evidence":null,"site_key":null,"winner_key":"GDYANG3BBHR6","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-10-27T04:48:32.497036Z","principal_notice_id":"e10b8c50725944f889771ac6d54d49ae","description":{"text":"2\n\nEffective Date: 01/15/2026\nRevision: 03\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-06.\n\nThis solicitation is set aside for SDVOSB business concerns.\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Phone calls with questions will not be accepted.\nPoint of Contact\nStephanie Naron, Contract Specialist, Stephanie.Naron@va.gov.\n\nStatement Of Work\n\nCONTRACT TITLE:\nElevator Inspections & Certification\n\nPLACE OF PERFORMANCES:\nVA San Diego Healthcare System\n3350 La Jolla Village Dr.\nSan Diego, CA 92161\n\nPERIOD OF PERFORMANCE:\nOne base year and four (4) option years.\n\nCONTRACT TYPE:\nFirm Fixed Price\n\nBACKGROUND:\nThis contract is for semi-annual inspections and maintenance review, annual/CAT 1 inspections, and safety testing of Government owned Vertical Transportation Units (VTUs) at the VA San Diego Healthcare System, to include elevators, dumbwaiters, wheelchair lifts, and cart lifts. All VTUs additionally require a 5-year/CAT 5 elevator test.\n\nGENERAL REQUIREMENTS:\n6.1. The Contractor shall furnish all equipment, expertise, incidentals, labor, materials, parts, supervision, supplies, tools, transportation, and qualified personnel required and necessary to conduct inspection services in accordance/compliance with manufacturer guidelines/recommendations, current code(s), directives, regulations, Joint Commission, and industry standards at VA San Deigo Healthcare System.\n6.2. Contractor shall check in with Electric Shop Supervisor or appointed prior to performing any work.\n6.3. Contractor and employees shall be issued temporary ID badges from the VA Police Department that must always be worn while on station.\n6.4. All damages incurred during the performance of this scope of work will be repaired by the Contractor at no cost to the VA.\n6.5. Contractor is responsible for providing and utilizing all OSHA regulated Personal Protective Equipment (PPE) while performing all inspection and testing requirements.\n6.6. Contractor shall follow all VA regulations and provide the means to meet these regulations.\n\nSPECIFIC REQUIREMENTS:\nThe Contractor shall provide independent elevator inspection services that include inspection, verification, and certification of annual and semi-annual inspection, semi-annual maintenance reviews, safety tests, and 5-year load testing to ensure reliable and continuous safe operation of Government owned VTU' s. A list of all VTUs can be found in SUPPLEMENT 1 - MASTER ELEVATOR INVENTORY (See Section 8). The list is subject to change throughout the performance of the contract and all parties involved will be notified of any changes within five (5) business days.\n7.1. Prior to performing independent inspection services, The Contractor shall provide notification to the COR and the Government Elevator Maintenance and Repair Contractor of the dates of proposed services. The notification should reach the Government and Elevator Maintenance and Repair Contractor at least fifteen (15) calendar days prior to the proposed inspection. The notification shall be in writing and shall include the proposed inspection and testing dates, estimated time of arrival and completion of services, name and local contact information of the technician performing the services.\n7.2. Inspections and tests shall be completed in accordance with the most current edition of the American Society of Mechanical Engineers (ASME) 17.1 Safety Code for Elevators and Escalators, ASME 17 .2 Guide for Inspection of Elevators, Escalators, and Moving Walks and ASME 17.3 Safety Code for Existing Elevators and Escalators. In addition, the Contractor shall be aware of and adhere to all applicable Federal, State, County and City, rules, recommendations, regulations, guidelines and laws pertaining to the execution of all inspection services.\n7.3. The Contractor shall provide the necessary labels, metal tags or other tagging and labeling according to requirements.\n7.4. The Contractor is responsible for ensuring services are provided by qualified and competent personnel for all Elevator Inspections pertinent to this contract. At a minimum, contractor personnel shall maintain a CURRENT ASME QEI 1 Certification.\n\nINVENTORY:\nThe Contractor responsible for providing required inspection for all VA San Diego Medical Center VTU s according to SUPPLEMENT 1 - MASTER ELEVATOR INVENTORY:\nBldg 1\nP1, P2, P3, P4, P5, P6, S1, S2, S3, S4, Research, dumbwaiter\n\n12\nMRI\nP1\n\n1\nBldg 11\nP1, P2, P3, P4, S1\n\n5\nBldg 26\nP1, P2, P5, P6, S1, S2, S3, S4\n\n8\nBldg 27\nP1, P2\n\n2\nBldg 28\nPG1\n\n1\nBldg 31\nPG2\n\n1\nBldg 32\nPG1, PG2, PG3, PG4\n\n4\nTotal\nÂ\n\n34\n\nDOCUMENTATION AND REPORTS:\nWithin ten (10) business days of the completion of an inspection or test, the Contractor shall complete and submit a separate written narrative report for each VTU inspected. The report shall include the date and time of the inspection or test, the location, the equipment, the type of service performed, actual hours spent performing requested service, and the name of the technician performing the service. The Contractor shall submit two (2) copies of each report in written format and one (1) copy in digital format to the designated COR of the facility inspected/tested, and the Elevator Maintenance Contractor of the facility inspected/tested on VA supplied forms.\n9.1. The report shall identify each VTU inspected or tested by building, serial and unit number. The report shall describe any needed adjustments, repairs, worn parts and other items required or recommended for keeping the-VTU operating safely. The report shall make specific reference to safety code violations, including the title of the code being cited, the section or clause which refers to the specific violation and other reference that will assist the COR and Elevator Maintenance and Repair contractor in making necessary repairs or adjustments.\n9.2. The report shall adhere to the reporting requirements of the publications listed in VA supplied forms and describe the general condition; state of repair and cleanliness of each VTU. The report shall describe the state of the surrounding pits, access, lighting, machine rooms, cabs and landings. In addition, the report shall include any Contractor recommendation(s) that will assist the Government in maintaining the equipment in optimum operating condition.\n9.3. The contractor shall fully complete and submit with report one (1) digital and two (2) paper copies of the most current version of SUPPLEMENT 2 - Checklist for Inspection of Electric Elevators and SUPPLEMENT 3 - Five (5) Year Full Load Test Inspection In lieu of the ASME approved forms listed above.\n9.4. During an inspection or test if the contractor discovers a defective VTU that requires immediate repair or service, he/she shall notify the COR and the Elevator Maintenance and Repair Contractor prior to leaving the facility where the defective VTU is located. The Contractor shall describe the location of the defective VTU, repairs or adjustment needed, and if the VTU can or should remain in service. Contractor shall follow-up in 24 hours with a written report of the defective VTU and describes the action taken to report needed repairs.\n\nCONTRACTOR'S QUALIFICATIONS:\nContractor's personnel performing on this Contract must be fully qualified competent service technician(s). \"Fully qualified\" is defined as meeting the requirements of the most current edition of ASME QEI-1 for the Qualification of Elevator Inspectors. The Contractor will be required to update competency information throughout the life of the contract as changes occur. The Contractor must provide for Government approval credentials of each service technician. Credentials must be provided prior to the employee being assigned services responsibilities on Government equipment listed herein. Contractors shall provide proof and adequacy of past performance history, references, and required qualifications.\n\nAPPLICABLE DOCUMENTS, STANDARDS, LAWS AND/OR REGULATIONS:\nThe following are a list of various applicable standards, policies, regulations, and/or governing bodies. This list isÂ· not an all-inclusive list, therefore it is the responsibility of the contractor to ensure all applicable standards, policies, regulations, and/or governing bodies not listed here are adhere to. Furthermore, contractor is responsible to adhere to all current addition of applicable standards, policies, regulations, and/or governing bodies.\n11.1. The American Society of Mechanical Engineers (ASME), www.asme.org\n11.2. ASME -A17 -Elevators and Escalators\n11.3. ASME -A17 .1 - Safety Code for Elevators and Escalators\n11.4. ASME-A17 .2 -Guide for Inspection of Elevators, Escalators, and Moving W a1ks\n11.5. ASME-A17.3 -Safety Code for Existing Elevators and Escalators (Includes Requirements for Electric and Hydraulic Elevators and Escalators)\n11.6. ASME-A18-.1-Safety Standards for Platform Lifts and Stairway Chairlifts\n11.7. ASME-QEI-1-Standard for the Qualification of Elevator Inspectors\n11.8. National Association of Elevator Safety Authorities International (NAESAI), www.naesai.org\n11.9. NFPA 70-National Electrical Code\n11.10. NFPA 70E -Standard for Electrical Safety in the Workplace\n\nSAFETY REQUIREMENTS:\nAll personnel employed by the Contractor in the performance of this contract, or any representative of the Contractor entering on VASDHS shall comply with applicable Federal, State, and VA safety and fire regulations and codes, which are in effect during the performance period of the contract.\nContractor shall perform work in strict accordance with existing relevant, accredited standards and codes to minimize the possibility of injury to personnel, or damage to Government equipment. Every effort shall be made to safeguard human life and property.\nContractor shall comply with all applicable Federal, State, and local requirements regarding workers health and safety. The requirements include, but are not limited to, those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR), Parts 1910 and 1926, NFPA 70E, Article 130.7 29 CFR 1910.132(d)(1)(iii), 29CFR1910.137\nContractor shall provide all necessary tools, and Personal Protective Equipment (PPE) to perform the work safely, effectively, and timely.\nThe VAMC San Diego building 1, main building, contains asbestos. Any worker entering these asbestos containing areas must have an asbestos certification of no less than 16 hours and a valid fit test certification. Certifications must be presented to the VA project manager before any work in an asbestos area may begin.\n\nCHANGES:\nThe awarded Contractor is advised that only the Contracting Officer, acting within the scope of the contract has the authority to make changes which affect the contract in terms of quality, quantity, price or delivery.\n\nIn the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered to have been made without authority and no adjustment shall be made in the contract price to cover any increase in costs incurred as a result thereof.\n\nVA POLICY:\nPossession of weapons is prohibited. Enclosed containers, including tool kits, are subject to search. Violations of VA regulations may result in citations answerable in the United States (Federal) District Court.\n\nPARKING POLICY:\nIt is the responsibility of Contractor personnel to park only in designated parking areas. Parking information is available from the VA Police. The VA shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nIDENTIFICATION BADGES:\nAll Contractor personnel are required to wear identification (I.D.) badges during the\nentire time they are on the VA Healthcare System grounds. I.D. badges must have an identification picture and shall state the name of the individual and the company represented.\n\nSMOKING POLICY:\nSmoking is not permitted within the VA Healthcare System facilities campus.\n\nNORMAL WORKING HOURS:\nNormal hours of operation are Monday through Friday from 08:00 am to 4:30 pm Pacific time. All work is expected to be performed generally during normal hours of coverage unless requested or approved by the COR or his/her designee.\n\nBefore commencement of work, the Contractor shall confer with the VA COR and Contracting Office to agree on a sequence of procedures; means of access to premises and building. All work performed, to include delivery of materials and equipment, shall be made with minimal interference to Government operations and personnel.\n\nWork performed outside the normal hours of coverage must be approved by the COR or his/her designee.\n\nOVERTIME AND NATIONAL HOLIDAYS:\nAny overtime or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government.\n\nThe Contractor is not required to provide service on the following U.S. Government holidays nor shall the Contractor be paid for these days:\n\nNew Year s Day\nJanuary 1\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day\nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day\nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeterans Day\nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25","html":"2\n\nEffective Date:  01/15/2026\nRevision: 03\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-06. \n\nThis solicitation is set aside for SDVOSB business concerns.\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Phone calls with questions will not be accepted.\nPoint of Contact\nStephanie Naron, Contract Specialist, Stephanie.Naron@va.gov. \n\nStatement Of Work\n\nCONTRACT TITLE:\nElevator Inspections & Certification\n\nPLACE OF PERFORMANCES:\nVA San Diego Healthcare System\n3350 La Jolla Village Dr.\nSan Diego, CA 92161\n\nPERIOD OF PERFORMANCE:\nOne base year and four (4) option years.\n\nCONTRACT TYPE:\nFirm Fixed Price\n\nBACKGROUND:\nThis contract is for semi-annual inspections and maintenance review, annual/CAT 1 inspections, and safety testing of Government owned Vertical Transportation Units (VTUs) at the VA San Diego Healthcare System, to include elevators, dumbwaiters, wheelchair lifts, and cart lifts. All VTUs additionally require a 5-year/CAT 5 elevator test.\n\nGENERAL REQUIREMENTS:\n6.1. The Contractor shall furnish all equipment, expertise, incidentals, labor, materials, parts, supervision, supplies, tools, transportation, and qualified personnel required and necessary to conduct inspection services in accordance/compliance with manufacturer guidelines/recommendations, current code(s), directives, regulations, Joint Commission, and industry standards at VA San Deigo Healthcare System.\n6.2. Contractor shall check in with Electric Shop Supervisor or appointed prior to performing any work.\n6.3. Contractor and employees shall be issued temporary ID badges from the VA Police Department that must always be worn while on station.\n6.4. All damages incurred during the performance of this scope of work will be repaired by the Contractor at no cost to the VA.\n6.5. Contractor is responsible for providing and utilizing all OSHA regulated Personal Protective Equipment (PPE) while performing all inspection and testing requirements.\n6.6. Contractor shall follow all VA regulations and provide the means to meet these regulations.\n\nSPECIFIC REQUIREMENTS: \nThe Contractor shall provide independent elevator inspection services that include inspection, verification, and certification of annual and semi-annual inspection, semi-annual maintenance reviews, safety tests, and 5-year load testing to ensure reliable and continuous safe operation of Government owned VTU' s. A list of all VTUs  can be found in SUPPLEMENT 1 - MASTER ELEVATOR INVENTORY (See Section 8). The list is subject to change throughout the performance of the contract and all parties involved will be notified of any changes within five (5) business days.\n7.1. Prior to performing independent inspection services, The Contractor shall provide notification to the COR and the Government Elevator Maintenance and Repair Contractor of the dates of proposed services. The notification should reach the Government and Elevator Maintenance and Repair Contractor at least fifteen (15) calendar days prior to the proposed inspection. The notification shall be in writing and shall include the proposed inspection and testing dates, estimated time of arrival and completion of services, name and local contact information of the technician performing the services.\n7.2. Inspections and tests shall be completed in accordance with the most current edition of the American Society of Mechanical Engineers (ASME) 17.1 Safety Code for Elevators and Escalators, ASME 17 .2 Guide for Inspection of Elevators, Escalators, and Moving Walks and ASME 17.3 Safety Code for Existing Elevators and Escalators. In addition, the Contractor shall be aware of and adhere to all applicable Federal, State, County and City, rules, recommendations, regulations, guidelines and laws pertaining to the execution of all inspection services.\n7.3. The Contractor shall provide the necessary labels, metal tags or other tagging and labeling according to requirements.\n7.4. The Contractor is responsible for ensuring services are provided by qualified and competent personnel for all Elevator Inspections pertinent to this contract. At a minimum, contractor personnel shall maintain a CURRENT ASME QEI 1 Certification.\n\nINVENTORY: \nThe Contractor responsible for providing required inspection for all VA San Diego Medical Center VTU s according to SUPPLEMENT 1 - MASTER ELEVATOR INVENTORY:\nBldg 1\nP1, P2, P3, P4, P5, P6, S1, S2, S3, S4, Research, dumbwaiter\n\n12\nMRI\nP1\n\n1\nBldg 11\nP1, P2, P3, P4, S1\n\n5\nBldg 26\nP1, P2, P5, P6, S1, S2, S3, S4\n\n8\nBldg 27\nP1, P2\n\n2\nBldg 28\nPG1\n\n1\nBldg 31\nPG2\n\n1\nBldg 32\nPG1, PG2, PG3, PG4\n\n4\nTotal\nÂ \n\n34\n\nDOCUMENTATION AND REPORTS: \nWithin ten (10) business days of the completion of an inspection or test, the Contractor shall complete and submit a separate written narrative report for each VTU inspected. The report shall include the date and time of the inspection or test, the location, the equipment, the type of service performed, actual hours spent performing requested service, and the name of the technician performing the service. The Contractor shall submit two (2) copies of each report in written format and one (1) copy in digital format to the designated COR of the facility inspected/tested, and the Elevator Maintenance Contractor of the facility inspected/tested on VA supplied forms.\n9.1. The report shall identify each VTU inspected or tested by building, serial and unit number. The report shall describe any needed adjustments, repairs, worn parts and other items required or recommended for keeping the-VTU operating safely. The report shall make specific reference to safety code violations, including the title of the code being cited, the section or clause which refers to the specific violation and other reference that will assist the COR and Elevator Maintenance and Repair contractor in making necessary repairs or adjustments.\n9.2. The report shall adhere to the reporting requirements of the publications listed in VA supplied forms and describe the general condition; state of repair and cleanliness of each VTU. The report shall describe the state of the surrounding pits, access, lighting, machine rooms, cabs and landings. In addition, the report shall include any Contractor recommendation(s) that will assist the Government in maintaining the equipment in optimum operating condition.\n9.3. The contractor shall fully complete and submit with report one (1) digital and two (2) paper copies of the most current version of SUPPLEMENT 2 - Checklist for Inspection of Electric Elevators and SUPPLEMENT 3 - Five (5) Year Full Load Test Inspection In lieu of the ASME approved forms listed above.\n9.4. During an inspection or test if the contractor discovers a defective VTU that requires immediate repair or service, he/she shall notify the COR and the Elevator Maintenance and Repair Contractor prior to leaving the facility where the defective VTU is located. The Contractor shall describe the location of the defective VTU, repairs or adjustment needed, and if the VTU can or should remain in service. Contractor shall follow-up in 24 hours with a written report of the defective VTU and describes the action taken to report needed repairs.\n\nCONTRACTOR'S QUALIFICATIONS: \nContractor's personnel performing on this Contract must be fully qualified competent service technician(s). \"Fully qualified\" is defined as meeting the requirements of the most current edition of ASME QEI-1 for the Qualification of Elevator Inspectors. The Contractor will be required to update competency information throughout the life of the contract as changes occur. The Contractor must provide for Government approval credentials of each service technician. Credentials must be provided prior to the employee being assigned services responsibilities on Government equipment listed herein. Contractors shall provide proof and adequacy of past performance history, references, and required qualifications.\n\nAPPLICABLE DOCUMENTS, STANDARDS, LAWS AND/OR REGULATIONS: \nThe following are a list of various applicable standards, policies, regulations, and/or governing bodies. This list isÂ· not an all-inclusive list, therefore it is the responsibility of the contractor to ensure all applicable standards, policies, regulations, and/or governing bodies not listed here are adhere to. Furthermore, contractor is responsible to adhere to all current addition of applicable standards, policies, regulations, and/or governing bodies.\n11.1. The American Society of Mechanical Engineers (ASME), www.asme.org\n11.2. ASME -A17 -Elevators and Escalators\n11.3. ASME -A17 .1 - Safety Code for Elevators and Escalators\n11.4. ASME-A17 .2 -Guide for Inspection of Elevators, Escalators, and Moving W a1ks\n11.5. ASME-A17.3 -Safety Code for Existing Elevators and Escalators (Includes Requirements for Electric and Hydraulic Elevators and Escalators)\n11.6. ASME-A18-.1-Safety Standards for Platform Lifts and Stairway Chairlifts\n11.7. ASME-QEI-1-Standard for the Qualification of Elevator Inspectors\n11.8. National Association of Elevator Safety Authorities International (NAESAI), www.naesai.org\n11.9. NFPA 70-National Electrical Code\n11.10. NFPA 70E -Standard for Electrical Safety in the Workplace\n\nSAFETY REQUIREMENTS:\nAll personnel employed by the Contractor in the performance of this contract, or any representative of the Contractor entering on VASDHS shall comply with applicable Federal, State, and VA safety and fire regulations and codes, which are in effect during the performance period of the contract.\nContractor shall perform work in strict accordance with existing relevant, accredited standards and codes to minimize the possibility of injury to personnel, or damage to Government equipment.  Every effort shall be made to safeguard human life and property.  \nContractor shall comply with all applicable Federal, State, and local requirements regarding workers  health and safety. The requirements include, but are not limited to, those found in Federal and State Occupational Safety and Health Act (OSHA) statutes and regulations, such as applicable provisions of Title 29, Code of Federal Regulations (CFR), Parts 1910 and 1926, NFPA 70E, Article 130.7 29 CFR 1910.132(d)(1)(iii), 29CFR1910.137\nContractor shall provide all necessary tools, and Personal Protective Equipment (PPE) to perform the work safely, effectively, and timely. \nThe VAMC San Diego building 1, main building, contains asbestos. Any worker entering these asbestos containing areas must have an asbestos certification of no less than 16 hours and a valid fit test certification. Certifications must be presented to the VA project manager before any work in an asbestos area may begin. \n\nCHANGES:\nThe awarded Contractor is advised that only the Contracting Officer, acting within the scope of the contract has the authority to make changes which affect the contract in terms of quality, quantity, price or delivery.\n\nIn the event the Contractor effects any such change at the direction of any person other than the Contracting Officer, the change shall be considered to have been made without authority and no adjustment shall be made in the contract price to cover any increase in costs incurred as a result thereof.\n\nVA POLICY:\nPossession of weapons is prohibited. Enclosed containers, including tool kits, are subject to search. Violations of VA regulations may result in citations answerable in the United States (Federal) District Court.\n\nPARKING POLICY:\nIt is the responsibility of Contractor personnel to park only in designated parking areas.  Parking information is available from the VA Police. The VA shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nIDENTIFICATION BADGES:\nAll Contractor personnel are required to wear identification (I.D.) badges during the \nentire time they are on the VA Healthcare System grounds. I.D. badges must have an identification picture and shall state the name of the individual and the company represented.\n\nSMOKING POLICY:\nSmoking is not permitted within the VA Healthcare System facilities campus.\n\nNORMAL WORKING HOURS:\nNormal hours of operation are Monday through Friday from 08:00 am to 4:30 pm Pacific time. All work is expected to be performed generally during normal hours of coverage unless requested or approved by the COR or his/her designee.\n\nBefore commencement of work, the Contractor shall confer with the VA COR and Contracting Office to agree on a sequence of procedures; means of access to premises and building. All work performed, to include delivery of materials and equipment, shall be made with minimal interference to Government operations and personnel.\n\nWork performed outside the normal hours of coverage must be approved by the COR or his/her designee.\n\nOVERTIME AND NATIONAL HOLIDAYS:\nAny overtime or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government.\n\nThe Contractor is not required to provide service on the following U.S. Government holidays nor shall the Contractor be paid for these days:\n\nNew Year s Day\nJanuary 1\nMartin Luther King  s Birthday\nThird Monday in January\nPresident s Day\nThird Monday in February\nMemorial Day \nLast Monday in May\nJuneteenth\nJune 19\nIndependence Day \nJuly 4\nLabor Day\nFirst Monday in September\nColumbus Day \nSecond Monday in October\nVeterans Day \nNovember 11\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25","origin":"detail"},"contacts":[{"name":"Stephanie Naron","role":"primary","email":"stephanie.naron@va.gov","phone":"520-792-1450 14387","title":"CONTRACT SPECIALIST"}],"place_of_performance":{"zip":"92161-0002","city":{"name":"San Diego"},"street":"Jennifer Moreno Department of Veterans Affairs Med Department of Veterans Affairs 3350 La Jolla Village Drive"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"naics_codes":["811310"],"award":null,"attachments":[{"resource_id":"ac3b4173795c4e72bd0b7c5bfa8a958b","name":"36C26226Q1387.docx","kind":"file","mime_type":".docx","size_bytes":26257,"posted_at":"2026-08-20T21:32:05.511Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ac3b4173795c4e72bd0b7c5bfa8a958b/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C26226P1664_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C26226P1664_3600_-NONE-_-NONE-/","piid":"36C26226P1664","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"GDYANG3BBHR6","recipient_name":"VETERAN ELEVATOR INSPECTION SERVICES, LLC","recipient_uei":"GDYANG3BBHR6","recipient_cage":"846S5","recipient_city":"KINSTON","recipient_state":"NC","sub_name":"Department of Veterans Affairs","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","office_key":"o-36C262","first_action_date":"2026-09-11","last_action_date":"2026-10-29","actions":2,"obligated":"21560.00","current_total_value":"21560.00","potential_total_value":"73580.00","naics":"811310","psc":"J035","extent_competed":"COMPETED UNDER SAP","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":3,"description":"ELEVATOR INSPECTION SERVICE","method":"solicitation","confidence":"high","evidence":["solicitation number 36C26226Q1387 equals the FPDS solicitation identifier","same awarding office 36C262"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C26227Q0085","latest_notice_id":"cdde3a94bda84b199f9d3db72af657a6","title":"S215--SDVOSB Furniture Installation Labor Storage - Base Plus Four Option Years | POP: (12/31/2026 - 12/30/2031) |","solicitation_number":"36C26227Q0085","notice_type":"o","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-23","notices":4,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"493190","psc":"S215","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C26227Q0079","latest_notice_id":"00646e7746494ab38ce53bbe9f7e0f59","title":"W065--RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT","solicitation_number":"36C26227Q0079","notice_type":"k","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-26T20:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"532490","psc":"W065","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0139","latest_notice_id":"156fef93406e495486eb1d4e805bb675","title":"6515--PYXIS IV PREP","solicitation_number":"36C26227Q0139","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541519","psc":"6515","set_aside":"SDVOSBC","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26227Q0146","latest_notice_id":"e2fc7d7b106d4b448a5b57cba568ddb4","title":"J041--KITCHEN HOOD PMIR - Base +4 ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0146","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"561790","psc":"J041","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T08:15:06.508374Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open":[{"key":"W912PL27QA001","latest_notice_id":"55fd39a8c25743939ed3ffe95d292b4e","title":"Material Handling Equipment (MHE) and Industrial Equipment (IE) Maintenance and Repair Services","solicitation_number":"W912PL27QA001","notice_type":"k","first_type":"k","first_posted":"2026-10-23","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-27T22:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","naics":"811310","psc":"J039","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"SOUTH EL MONTE, CA 91733","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0107","latest_notice_id":"6a5b19d6e316483386c61a63f786b4fa","title":"J041--VA Long Beach Healthcare System (VALBHS) Recurring Maintenance for Metasys Building Automation System and four (4) YORK Chillers","solicitation_number":"36C26227Q0107","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"811310","psc":"J041","set_aside":null,"state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C26127Q0169","latest_notice_id":"9989888cf8614c8e87f9894ee00a31e7","title":"J012--Dry-Type Fire Suppression System","solicitation_number":"36C26127Q0169","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-30T23:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"811310","psc":"J012","set_aside":null,"state":"CA","county":"06085","county_name":"Santa Clara County","city":"0655282","city_name":"Palo Alto","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":56,"indexable":false}