{"canonical":"https://sealedbidder.com/opportunities/36c26226q0424","key":"36C26226Q0424","url":"https://sealedbidder.com/opportunities/36c26226q0424","title":"6515--Radiation Therapy Phantom","solicitation_number":"36C26226Q0424","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-05T00:00:00Z","first_posted":"2026-02-26","last_posted":"2026-02-26","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"334510","psc":"6515","set_aside":null,"place_state":"CA","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"06037","place_county_name":"Los Angeles County","place_city":"0644000","place_city_name":"Los Angeles","winner":null,"award_amount":null,"publications":[{"notice_id":"1b98b0eca09149c3acdda6a79231624e","title":"6515--Radiation Therapy Phantom","solicitation_number":"36C26226Q0424","notice_type":"p","base_type":"p","posted":"2026-02-26","posted_at":"2026-02-26T20:25:18.351Z","due_at":"2026-03-05T00:00:00Z","due_date":"2026-03-04","cancelled":false,"archived":true,"archive_date":"2026-04-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1b98b0eca09149c3acdda6a79231624e/view","enriched":true,"history":[{"index":3,"title":"6515--Radiation Therapy Phantom","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-26T20:25:18.351Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"1b98b0eca09149c3acdda6a79231624e","solicitation_number":"36C26226Q0424"}]}],"latest_notice_id":"1b98b0eca09149c3acdda6a79231624e","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-02-26","posted_at":"2026-02-26T20:25:18.351Z","created_at":"2026-02-26T20:25:15.846Z","modified_at":"2026-04-04T03:55:52.536Z","response_deadline":{"raw":"2026-03-04T16:00:00-08:00","utc":"2026-03-05T00:00:00Z","date":"2026-03-04","time":"16:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1b98b0eca09149c3acdda6a79231624e/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6515--Radiation Therapy Phantom","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-03","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Radiation Therapy Phantom","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-26T20:25:18.351Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"1b98b0eca09149c3acdda6a79231624e","solicitation_number":"36C26226Q0424"}],"contacts":[{"name":"Nate Munson","role":"primary","email":"nathan.munson@va.gov","phone":"562-681-2951","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"1b98b0eca09149c3acdda6a79231624e","lineage_id":"1b98b0eca09149c3acdda6a79231624e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-12T02:41:56.371725500Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"26fa6a6dcfc5ade1dfb0a87a6f15f13a74428b1344659e936a85b87c76171227","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-12T02:41:56.371725500Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"This request for information (RFI/Sources Sought) is issued solely for information and planning purposes. This is NOT a solicitation.\nTHERE ARE 19 QUESTIONS AT THE BOTTOM OF THIS DOCUMENT. PLEASE ANSWER THEM COMPLETELY AND THOROUGHLY.\nThe submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI in accordance with (IAW) Far 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought Notice / RFI only.  The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1,250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.  \nThe Department of Veterans Affairs (VA) is seeking sources capable of providing a Radiation Therapy Phantom. \n(1) \nManufacturer: Sun Nuclear\nItem Description: Radiation Therapy Phantom\nQuantity: 1 \nComponents must include: \nDaily ISO Phantom (Part #: 023)\n6DOF ISO Base (Part #: 023-08)\nInsert Rod   Aluminum   Advanced Electron Density Phantom Model 1467 (Part #805779)\nInsert Rod - Titanium - Advanced Electron Density Phantom Model 1467 (Part #805780)\nInsert Rod - Stainless Steel - Advanced Electron Density Phantom Model 1467 (Part #805781)\nAdvanced Electron Density Phantom (Part #805810)\nRapidCHECK Automation Analysis Software Platform (Part #806017)\n\nEqual to product Information:\nMain component: Radiation Therapy Phantom\n\nSalient Characteristics\nDaily Isocenter Phantom + Six Degrees of Freedom Isocenter Base \nMust provide a repeatable method for verifying alignment of image guidance\nsystems, including but not limited to: megavoltage, kilovoltage, Cone-Beamed Computed Tomography, laser, and couch positioning.\nMust ensure coincidence between the radiation field, light field, and imaging isocenter.\nMust meet the American Association of Physicists in Medicine Task Group 142 recommendations for daily imaging Quality Assurance.\nMust be compatible with automated analysis platforms for consistent reporting and trending.\nMust provide a precision base compatible with the Daily Isocenter Phantom.\nMust enable accurate three dimensional and 6-degree-of-freedom shift calculations to verify robotic couch accuracy.\nMust allow stable and repeatable phantom positioning for daily Quality Assurance checks.\nMust be compatible with Sun Nuclear Quality Assurance tools and analysis software currently in use at the Greater Los Angeles VA.\n\nAdvanced Electron Density Phantom + extra Insert Rods   for Advanced Electron Density Phantom (Aluminum Insert Rod, Titanium Insert Rod, Stainless Steel Insert Rod) + software\nMust include full-length (exactly 16.5 cm) material-specific inserts for Computed Tomography to-electron density calibration.\nMust simulate various tissue-equivalent materials for accurate Hounsfield Units-to-density correlation.\nMust be compatible with the Advanced Electron Density Phantom currently in use at the Greater Los Angeles VA.\nMust meet calibration requirements for treatment planning system commissioning.\nMust provide a precision-molded phantom for Computed Tomography Quality Assurance and electron density calibration.\nMust represent head and torso geometry with known density inserts based on International Commission on Radiation Units and Measurements Report 44 standards.\nMust allow correlation between Hounsfield Units and electron density for accurate dose calculation.\nMust support periodic calibration and verification procedures required by regulatory and clinical standards.\nSoftware must be able to do Computed Tomography-to density calibration automated on Advanced Electron Density Phantom, and CT image Quality Analysis, browser-based, platform and data to be stored locally.Â  \n\n\nThe list of salient characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. \nIf your company is interested and capable of providing the required supplies, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) As defined in FAR Part 52.225-1 regarding the Buy American Act, please list the country of origin for each line item.\n(2) Submit your capabilities statement illustrating how your organization can/cannot meet the list of salient characteristics requirements.  For instances where your company cannot meet the salient characteristics requirement(s), please explain.  For instances where your company can meet the salient characteristics requirement(s), please show how your company meets/exceeds each requirement.  \n(3) Please review the list of salient characteristics requirements and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(4) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(5) Is your company considered small under the NAICS code identified in this RFI?\n(6) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of salient characteristics?\n(7) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(8) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(9) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(10) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(11) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(12) What is your lead time to deliver a single unit with all components?  Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution?  What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance?  Please specify what FDA clearance(s) have been obtained.\n(15) Does your organization offer a leasing solution?  Please elaborate.\n(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Nathan.munson@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Wednesday, March 4th, 2026 by 4:00 PM EST.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only.  Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","text":"This request for information (RFI/Sources Sought) is issued solely for information and planning purposes. This is NOT a solicitation.\nTHERE ARE 19 QUESTIONS AT THE BOTTOM OF THIS DOCUMENT. PLEASE ANSWER THEM COMPLETELY AND THOROUGHLY.\nThe submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI in accordance with (IAW) Far 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1,250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA) is seeking sources capable of providing a Radiation Therapy Phantom.\n(1)\nManufacturer: Sun Nuclear\nItem Description: Radiation Therapy Phantom\nQuantity: 1\nComponents must include:\nDaily ISO Phantom (Part #: 023)\n6DOF ISO Base (Part #: 023-08)\nInsert Rod Aluminum Advanced Electron Density Phantom Model 1467 (Part #805779)\nInsert Rod - Titanium - Advanced Electron Density Phantom Model 1467 (Part #805780)\nInsert Rod - Stainless Steel - Advanced Electron Density Phantom Model 1467 (Part #805781)\nAdvanced Electron Density Phantom (Part #805810)\nRapidCHECK Automation Analysis Software Platform (Part #806017)\n\nEqual to product Information:\nMain component: Radiation Therapy Phantom\n\nSalient Characteristics\nDaily Isocenter Phantom + Six Degrees of Freedom Isocenter Base\nMust provide a repeatable method for verifying alignment of image guidance\nsystems, including but not limited to: megavoltage, kilovoltage, Cone-Beamed Computed Tomography, laser, and couch positioning.\nMust ensure coincidence between the radiation field, light field, and imaging isocenter.\nMust meet the American Association of Physicists in Medicine Task Group 142 recommendations for daily imaging Quality Assurance.\nMust be compatible with automated analysis platforms for consistent reporting and trending.\nMust provide a precision base compatible with the Daily Isocenter Phantom.\nMust enable accurate three dimensional and 6-degree-of-freedom shift calculations to verify robotic couch accuracy.\nMust allow stable and repeatable phantom positioning for daily Quality Assurance checks.\nMust be compatible with Sun Nuclear Quality Assurance tools and analysis software currently in use at the Greater Los Angeles VA.\n\nAdvanced Electron Density Phantom + extra Insert Rods for Advanced Electron Density Phantom (Aluminum Insert Rod, Titanium Insert Rod, Stainless Steel Insert Rod) + software\nMust include full-length (exactly 16.5 cm) material-specific inserts for Computed Tomography to-electron density calibration.\nMust simulate various tissue-equivalent materials for accurate Hounsfield Units-to-density correlation.\nMust be compatible with the Advanced Electron Density Phantom currently in use at the Greater Los Angeles VA.\nMust meet calibration requirements for treatment planning system commissioning.\nMust provide a precision-molded phantom for Computed Tomography Quality Assurance and electron density calibration.\nMust represent head and torso geometry with known density inserts based on International Commission on Radiation Units and Measurements Report 44 standards.\nMust allow correlation between Hounsfield Units and electron density for accurate dose calculation.\nMust support periodic calibration and verification procedures required by regulatory and clinical standards.\nSoftware must be able to do Computed Tomography-to density calibration automated on Advanced Electron Density Phantom, and CT image Quality Analysis, browser-based, platform and data to be stored locally.Â\n\nThe list of salient characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.\nIf your company is interested and capable of providing the required supplies, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) As defined in FAR Part 52.225-1 regarding the Buy American Act, please list the country of origin for each line item.\n(2) Submit your capabilities statement illustrating how your organization can/cannot meet the list of salient characteristics requirements. For instances where your company cannot meet the salient characteristics requirement(s), please explain. For instances where your company can meet the salient characteristics requirement(s), please show how your company meets/exceeds each requirement.\n(3) Please review the list of salient characteristics requirements and provide any additional feedback or suggestions. If none, please reply as N/A.\n(4) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(5) Is your company considered small under the NAICS code identified in this RFI?\n(6) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of salient characteristics?\n(7) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(8) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(9) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(10) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(11) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution? What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.\n(15) Does your organization offer a leasing solution? Please elaborate.\n(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Nathan.munson@va.gov. Telephone responses will not be accepted. Responses must be received no later than Wednesday, March 4th, 2026 by 4:00 PM EST.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C26226Q0424","place_of_performance":{"zip":"90073","city":{"name":"Los Angeles"},"state":{"name":"CA"},"street":"VAMC Greater Los Angeles","country":{"code":"USA","name":"UNITED STATES"},"street2":"11301 Wilshire Blvd"},"product_service_code":"6515"}],"due_at":"2026-03-05T00:00:00Z","due_date":"2026-03-04","closes_at":"2026-03-05T00:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0644000","city_name":"Los Angeles","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-12T03:18:41.156832Z","principal_notice_id":"1b98b0eca09149c3acdda6a79231624e","description":{"text":"This request for information (RFI/Sources Sought) is issued solely for information and planning purposes. This is NOT a solicitation.\nTHERE ARE 19 QUESTIONS AT THE BOTTOM OF THIS DOCUMENT. PLEASE ANSWER THEM COMPLETELY AND THOROUGHLY.\nThe submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI in accordance with (IAW) Far 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1,250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA) is seeking sources capable of providing a Radiation Therapy Phantom.\n(1)\nManufacturer: Sun Nuclear\nItem Description: Radiation Therapy Phantom\nQuantity: 1\nComponents must include:\nDaily ISO Phantom (Part #: 023)\n6DOF ISO Base (Part #: 023-08)\nInsert Rod Aluminum Advanced Electron Density Phantom Model 1467 (Part #805779)\nInsert Rod - Titanium - Advanced Electron Density Phantom Model 1467 (Part #805780)\nInsert Rod - Stainless Steel - Advanced Electron Density Phantom Model 1467 (Part #805781)\nAdvanced Electron Density Phantom (Part #805810)\nRapidCHECK Automation Analysis Software Platform (Part #806017)\n\nEqual to product Information:\nMain component: Radiation Therapy Phantom\n\nSalient Characteristics\nDaily Isocenter Phantom + Six Degrees of Freedom Isocenter Base\nMust provide a repeatable method for verifying alignment of image guidance\nsystems, including but not limited to: megavoltage, kilovoltage, Cone-Beamed Computed Tomography, laser, and couch positioning.\nMust ensure coincidence between the radiation field, light field, and imaging isocenter.\nMust meet the American Association of Physicists in Medicine Task Group 142 recommendations for daily imaging Quality Assurance.\nMust be compatible with automated analysis platforms for consistent reporting and trending.\nMust provide a precision base compatible with the Daily Isocenter Phantom.\nMust enable accurate three dimensional and 6-degree-of-freedom shift calculations to verify robotic couch accuracy.\nMust allow stable and repeatable phantom positioning for daily Quality Assurance checks.\nMust be compatible with Sun Nuclear Quality Assurance tools and analysis software currently in use at the Greater Los Angeles VA.\n\nAdvanced Electron Density Phantom + extra Insert Rods for Advanced Electron Density Phantom (Aluminum Insert Rod, Titanium Insert Rod, Stainless Steel Insert Rod) + software\nMust include full-length (exactly 16.5 cm) material-specific inserts for Computed Tomography to-electron density calibration.\nMust simulate various tissue-equivalent materials for accurate Hounsfield Units-to-density correlation.\nMust be compatible with the Advanced Electron Density Phantom currently in use at the Greater Los Angeles VA.\nMust meet calibration requirements for treatment planning system commissioning.\nMust provide a precision-molded phantom for Computed Tomography Quality Assurance and electron density calibration.\nMust represent head and torso geometry with known density inserts based on International Commission on Radiation Units and Measurements Report 44 standards.\nMust allow correlation between Hounsfield Units and electron density for accurate dose calculation.\nMust support periodic calibration and verification procedures required by regulatory and clinical standards.\nSoftware must be able to do Computed Tomography-to density calibration automated on Advanced Electron Density Phantom, and CT image Quality Analysis, browser-based, platform and data to be stored locally.Â\n\nThe list of salient characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.\nIf your company is interested and capable of providing the required supplies, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) As defined in FAR Part 52.225-1 regarding the Buy American Act, please list the country of origin for each line item.\n(2) Submit your capabilities statement illustrating how your organization can/cannot meet the list of salient characteristics requirements. For instances where your company cannot meet the salient characteristics requirement(s), please explain. For instances where your company can meet the salient characteristics requirement(s), please show how your company meets/exceeds each requirement.\n(3) Please review the list of salient characteristics requirements and provide any additional feedback or suggestions. If none, please reply as N/A.\n(4) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(5) Is your company considered small under the NAICS code identified in this RFI?\n(6) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of salient characteristics?\n(7) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(8) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(9) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(10) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(11) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution? What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.\n(15) Does your organization offer a leasing solution? Please elaborate.\n(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Nathan.munson@va.gov. Telephone responses will not be accepted. Responses must be received no later than Wednesday, March 4th, 2026 by 4:00 PM EST.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","html":"This request for information (RFI/Sources Sought) is issued solely for information and planning purposes. This is NOT a solicitation.\nTHERE ARE 19 QUESTIONS AT THE BOTTOM OF THIS DOCUMENT. PLEASE ANSWER THEM COMPLETELY AND THOROUGHLY.\nThe submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this RFI in accordance with (IAW) Far 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought Notice / RFI only.  The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 334510 (size standard of 1,250 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.  \nThe Department of Veterans Affairs (VA) is seeking sources capable of providing a Radiation Therapy Phantom. \n(1) \nManufacturer: Sun Nuclear\nItem Description: Radiation Therapy Phantom\nQuantity: 1 \nComponents must include: \nDaily ISO Phantom (Part #: 023)\n6DOF ISO Base (Part #: 023-08)\nInsert Rod   Aluminum   Advanced Electron Density Phantom Model 1467 (Part #805779)\nInsert Rod - Titanium - Advanced Electron Density Phantom Model 1467 (Part #805780)\nInsert Rod - Stainless Steel - Advanced Electron Density Phantom Model 1467 (Part #805781)\nAdvanced Electron Density Phantom (Part #805810)\nRapidCHECK Automation Analysis Software Platform (Part #806017)\n\nEqual to product Information:\nMain component: Radiation Therapy Phantom\n\nSalient Characteristics\nDaily Isocenter Phantom + Six Degrees of Freedom Isocenter Base \nMust provide a repeatable method for verifying alignment of image guidance\nsystems, including but not limited to: megavoltage, kilovoltage, Cone-Beamed Computed Tomography, laser, and couch positioning.\nMust ensure coincidence between the radiation field, light field, and imaging isocenter.\nMust meet the American Association of Physicists in Medicine Task Group 142 recommendations for daily imaging Quality Assurance.\nMust be compatible with automated analysis platforms for consistent reporting and trending.\nMust provide a precision base compatible with the Daily Isocenter Phantom.\nMust enable accurate three dimensional and 6-degree-of-freedom shift calculations to verify robotic couch accuracy.\nMust allow stable and repeatable phantom positioning for daily Quality Assurance checks.\nMust be compatible with Sun Nuclear Quality Assurance tools and analysis software currently in use at the Greater Los Angeles VA.\n\nAdvanced Electron Density Phantom + extra Insert Rods   for Advanced Electron Density Phantom (Aluminum Insert Rod, Titanium Insert Rod, Stainless Steel Insert Rod) + software\nMust include full-length (exactly 16.5 cm) material-specific inserts for Computed Tomography to-electron density calibration.\nMust simulate various tissue-equivalent materials for accurate Hounsfield Units-to-density correlation.\nMust be compatible with the Advanced Electron Density Phantom currently in use at the Greater Los Angeles VA.\nMust meet calibration requirements for treatment planning system commissioning.\nMust provide a precision-molded phantom for Computed Tomography Quality Assurance and electron density calibration.\nMust represent head and torso geometry with known density inserts based on International Commission on Radiation Units and Measurements Report 44 standards.\nMust allow correlation between Hounsfield Units and electron density for accurate dose calculation.\nMust support periodic calibration and verification procedures required by regulatory and clinical standards.\nSoftware must be able to do Computed Tomography-to density calibration automated on Advanced Electron Density Phantom, and CT image Quality Analysis, browser-based, platform and data to be stored locally.Â  \n\n\nThe list of salient characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. \nIf your company is interested and capable of providing the required supplies, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) As defined in FAR Part 52.225-1 regarding the Buy American Act, please list the country of origin for each line item.\n(2) Submit your capabilities statement illustrating how your organization can/cannot meet the list of salient characteristics requirements.  For instances where your company cannot meet the salient characteristics requirement(s), please explain.  For instances where your company can meet the salient characteristics requirement(s), please show how your company meets/exceeds each requirement.  \n(3) Please review the list of salient characteristics requirements and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(4) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(5) Is your company considered small under the NAICS code identified in this RFI?\n(6) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of salient characteristics?\n(7) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(8) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(9) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(10) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(11) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(12) What is your lead time to deliver a single unit with all components?  Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution?  What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance?  Please specify what FDA clearance(s) have been obtained.\n(15) Does your organization offer a leasing solution?  Please elaborate.\n(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Nathan.munson@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Wednesday, March 4th, 2026 by 4:00 PM EST.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only.  Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","origin":"detail"},"contacts":[{"name":"Nate Munson","role":"primary","email":"nathan.munson@va.gov","phone":"562-681-2951","title":"Contract Specialist"}],"place_of_performance":{"zip":"90073","city":{"name":"Los Angeles"},"state":{"name":"CA"},"street":"VAMC Greater Los Angeles","country":{"code":"USA","name":"UNITED STATES"},"street2":"11301 Wilshire Blvd"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"naics_codes":["334510"],"award":{"awardee":{}},"attachments":[{"resource_id":"5be9333e89af44daae4d1cde248bc38e","name":"36C26226Q0424.docx","kind":"file","mime_type":".docx","size_bytes":22011,"posted_at":"2026-02-26T20:25:18.351Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5be9333e89af44daae4d1cde248bc38e/download","mirrored":false}],"awards":[],"related":[{"key":"36C26227Q0085","latest_notice_id":"cdde3a94bda84b199f9d3db72af657a6","title":"S215--SDVOSB Furniture Installation Labor Storage - Base Plus Four Option Years | POP: (12/31/2026 - 12/30/2031) |","solicitation_number":"36C26227Q0085","notice_type":"o","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-23","notices":4,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"493190","psc":"S215","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C26227Q0079","latest_notice_id":"00646e7746494ab38ce53bbe9f7e0f59","title":"W065--RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT","solicitation_number":"36C26227Q0079","notice_type":"k","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-26T20:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"532490","psc":"W065","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0139","latest_notice_id":"156fef93406e495486eb1d4e805bb675","title":"6515--PYXIS IV PREP","solicitation_number":"36C26227Q0139","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541519","psc":"6515","set_aside":"SDVOSBC","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26227Q0146","latest_notice_id":"e2fc7d7b106d4b448a5b57cba568ddb4","title":"J041--KITCHEN HOOD PMIR - Base +4 ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0146","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"561790","psc":"J041","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T08:15:06.508374Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open":[{"key":"36C24W27Q0015","latest_notice_id":"43d6da02565949a2894d236e511e6d21","title":"Audiological Diagnostic Testing Equipment","solicitation_number":"36C24W27Q0015","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-09T16:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C24W","office_name":"RPO WEST (36C24W)","naics":"334510","psc":"6515","set_aside":null,"state":"CA","county":"06001","county_name":"Alameda County","city":"0653000","city_name":"Oakland","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"REQTIHS202600220","latest_notice_id":"ef16a1513b85491d928fcb190b3fe772","title":"Vital Signs Monitoring and Physical Assessment Units","solicitation_number":"REQT-IHS-2026-00220","notice_type":"r","first_type":"r","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-26T01:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H713","office_name":"INDIAN HEALTH SERVICE","naics":"334510","psc":"6515","set_aside":null,"state":"OR","county":"41047","county_name":"Marion County","city":"4164900","city_name":"Salem","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":12,"indexable":false}