{"canonical":"https://sealedbidder.com/opportunities/36c26226q0377","key":"36C26226Q0377","url":"https://sealedbidder.com/opportunities/36c26226q0377","title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","solicitation_number":"36C26226Q0377","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-12T16:00:00Z","first_posted":"2026-03-03","last_posted":"2026-09-15","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541380","psc":"F107","set_aside":"SDVOSBC","place_state":"CA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"06037","place_county_name":"Los Angeles County","place_city":"0643000","place_city_name":"Long Beach","winner":"GDM-AE, INC.","award_amount":"3407203.00","publications":[{"notice_id":"b3e1e3ecfeb94cd7b303b42a2dca4086","title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","solicitation_number":"36C26226Q0377","notice_type":"r","base_type":"r","posted":"2026-03-03","posted_at":"2026-03-04T00:05:33.116Z","due_at":"2026-03-10T16:00:00Z","due_date":"2026-03-10","cancelled":false,"archived":true,"archive_date":"2026-04-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b3e1e3ecfeb94cd7b303b42a2dca4086/view","enriched":true,"history":[{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-04T00:05:33.116Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b3e1e3ecfeb94cd7b303b42a2dca4086","solicitation_number":"36C26226Q0377"}]},{"notice_id":"87ac12afb9c7474aba576e5ef17cf7dd","title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","solicitation_number":"36C26226Q0377","notice_type":"k","base_type":"k","posted":"2026-06-10","posted_at":"2026-06-10T20:21:09.816Z","due_at":"2026-06-16T16:00:00Z","due_date":"2026-06-16","cancelled":false,"archived":true,"archive_date":"2026-08-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/87ac12afb9c7474aba576e5ef17cf7dd/view","enriched":true,"history":[{"index":4,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-28T20:34:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"eafe5f131f5b4adb820db4f22592b89a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T17:59:53.488Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf2ef133b1e049a08ee95243f9fdb72b","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T20:21:09.816Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd","solicitation_number":"36C26226Q0377"}]},{"notice_id":"cf2ef133b1e049a08ee95243f9fdb72b","title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","solicitation_number":"36C26226Q0377","notice_type":"k","base_type":"k","posted":"2026-06-15","posted_at":"2026-06-15T17:59:53.488Z","due_at":"2026-06-22T16:00:00Z","due_date":"2026-06-22","cancelled":false,"archived":true,"archive_date":"2026-08-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cf2ef133b1e049a08ee95243f9fdb72b/view","enriched":true,"history":[{"index":4,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-28T20:34:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"eafe5f131f5b4adb820db4f22592b89a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T17:59:53.488Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf2ef133b1e049a08ee95243f9fdb72b","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T20:21:09.816Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd","solicitation_number":"36C26226Q0377"}]},{"notice_id":"eafe5f131f5b4adb820db4f22592b89a","title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","solicitation_number":"36C26226Q0377","notice_type":"k","base_type":"k","posted":"2026-07-28","posted_at":"2026-07-28T20:34:27.915Z","due_at":"2026-08-12T16:00:00Z","due_date":"2026-08-12","cancelled":false,"archived":true,"archive_date":"2026-11-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/eafe5f131f5b4adb820db4f22592b89a/view","enriched":true,"history":[{"index":4,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-28T20:34:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"eafe5f131f5b4adb820db4f22592b89a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T17:59:53.488Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf2ef133b1e049a08ee95243f9fdb72b","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T20:21:09.816Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd","solicitation_number":"36C26226Q0377"}]},{"notice_id":"0353a2ca22124c3ba58e31d2f8c46d3a","title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","solicitation_number":"36C26226Q0377","notice_type":"k","base_type":"k","posted":"2026-08-06","posted_at":"2026-08-06T21:20:45.857Z","due_at":"2026-08-12T16:00:00Z","due_date":"2026-08-12","cancelled":false,"archived":true,"archive_date":"2026-10-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0353a2ca22124c3ba58e31d2f8c46d3a/view","enriched":true,"history":[{"index":5,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-15T14:20:49.361Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"3a9b92fedffd4bdc8db52a58fc349144","solicitation_number":"36C26226Q0377","related_opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a"},{"index":4,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-28T20:34:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"eafe5f131f5b4adb820db4f22592b89a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T17:59:53.488Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf2ef133b1e049a08ee95243f9fdb72b","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T20:21:09.816Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd","solicitation_number":"36C26226Q0377"}]},{"notice_id":"3a9b92fedffd4bdc8db52a58fc349144","title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","solicitation_number":"36C26226Q0377","notice_type":"a","base_type":"k","posted":"2026-09-15","posted_at":"2026-09-15T14:20:49.361Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-15","removed_at":null,"award_number":"36C26226C0309","awardee_name":"GDM-AE, Inc.","amount":"3407203.00","link_sam":"https://sam.gov/workspace/contract/opp/3a9b92fedffd4bdc8db52a58fc349144/view","enriched":true,"history":[{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-15T14:20:49.361Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"3a9b92fedffd4bdc8db52a58fc349144","solicitation_number":"36C26226Q0377","related_opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"}]}],"latest_notice_id":"3a9b92fedffd4bdc8db52a58fc349144","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-03-03","posted_at":"2026-03-04T00:05:33.116Z","created_at":"2026-03-04T00:05:26.586Z","modified_at":"2026-04-10T04:04:31.638Z","response_deadline":{"raw":"2026-03-10T10:00:00-06:00","utc":"2026-03-10T16:00:00Z","date":"2026-03-10","time":"10:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b3e1e3ecfeb94cd7b303b42a2dca4086/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-09","archive_type":"auto_custom"},"history":[{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-04T00:05:33.116Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b3e1e3ecfeb94cd7b303b42a2dca4086","solicitation_number":"36C26226Q0377"}],"contacts":[{"name":"Lori Gammage","role":"primary","email":"lorenza.gammage@va.gov","phone":"602-795-4135","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"b3e1e3ecfeb94cd7b303b42a2dca4086","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"b3e1e3ecfeb94cd7b303b42a2dca4086","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-12T01:17:24.359093643Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"7d5d9e9e1469254f54152cc55a70666acb1b6526af364de7f2be622c9a5fb0e2","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-12T01:17:24.359093643Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 13, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is Sources Sought/RFI only.  The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 541620 (size standard $19M. Responses to this Sources Sought/RFI will be used by the Government to make appropriate acquisition decisions.  After reviewing the responses to this Sources Sought/RFI, a solicitation announcement may be published.  Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.  \nThe Department of Veterans Affairs (VA), Network Contracting Office 22, is seeking sources who can possibly provide asbestos, lead based paint, randon gas  and other hazardous materials testing, for the VA Medical Center located in Long Beach, CA. .\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the services that fulfill the required specifications. \nStatement of Work: \nThe U.S. Department of Veterans Affairs (VA) Tibor Rubin Long   Beach VA Hospital located at 5901 East 7th Street, Long Beach, CA 90822, is seeking a contractor to survey and assess all the buildings in the Tibor Rubin VA Medical Center for asbestos, lead based paint and other Hazardous materials (ALBHM).  \nContractor shall furnish all labor, equipment (including PPE), certification, supervision, and materials necessary to perform all operations in connection with this order.  Contract or shall perform work in strict accordance with the General Specifications, Statement of Work, schedule, and all other supporting documents. \nThe survey shall include a visual evaluation and sampling of the following: potential asbestos-containing materials (ACM), lead-based paint, radon gas and other potentially hazardous materials. This ALBHM survey will summarize the work conducted; discusses findings regarding the location, quantity, and condition of hazardous materials; and includes recommendations for addressing identified or potential hazards through abatement or management practices.\nThe survey location shall be for all buildings and structures at the Tibor Rubin VA Medical Center located at 5901 East 7th Street, Long Beach California 90822, consisting approximately of 1.2 million square feet on a 100-acre lot. All work shall be in accordance with the VALBMC, Local, State, and Federal codes and laws. \nIf you are interested and are capable of providing the sought-out services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n(2) Is your company considered small under the NAICS code identified in this RFI?\n(3) If you are a large business, do you have any designated subcontractors who can perform these services? If so, please provide their company name, telephone, point of Contact and size status (if available).\n(4) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\n(5) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number.\n(6) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the services you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract.\n(7) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award.\n(8) Please submit your capabilities statement illustrating your organization s ability to meet the described statement of work for planning purposes; show clear, compelling and convincing evidence that your organization meets all the requirements in the statement of work.\n(9) Please review statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n(10) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Lorenza.gammage@va.gov. Telephone responses will not be accepted.  Responses must be received no later than March 10, 2026, by 10:00 MST.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement. \nResponses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.\nNotice to Potential Offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM).\n\nAdditionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Veteran Small Business (VetCert) located at Veteran Small Business Certification (sba.gov).","text":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 13, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is Sources Sought/RFI only. The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 541620 (size standard $19M. Responses to this Sources Sought/RFI will be used by the Government to make appropriate acquisition decisions. After reviewing the responses to this Sources Sought/RFI, a solicitation announcement may be published. Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.\nThe Department of Veterans Affairs (VA), Network Contracting Office 22, is seeking sources who can possibly provide asbestos, lead based paint, randon gas and other hazardous materials testing, for the VA Medical Center located in Long Beach, CA. .\nThe information identified above is intended to be descriptive, not restrictive and to indicate the quality of the services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the services that fulfill the required specifications.\nStatement of Work:\nThe U.S. Department of Veterans Affairs (VA) Tibor Rubin Long Beach VA Hospital located at 5901 East 7th Street, Long Beach, CA 90822, is seeking a contractor to survey and assess all the buildings in the Tibor Rubin VA Medical Center for asbestos, lead based paint and other Hazardous materials (ALBHM).\nContractor shall furnish all labor, equipment (including PPE), certification, supervision, and materials necessary to perform all operations in connection with this order. Contract or shall perform work in strict accordance with the General Specifications, Statement of Work, schedule, and all other supporting documents.\nThe survey shall include a visual evaluation and sampling of the following: potential asbestos-containing materials (ACM), lead-based paint, radon gas and other potentially hazardous materials. This ALBHM survey will summarize the work conducted; discusses findings regarding the location, quantity, and condition of hazardous materials; and includes recommendations for addressing identified or potential hazards through abatement or management practices.\nThe survey location shall be for all buildings and structures at the Tibor Rubin VA Medical Center located at 5901 East 7th Street, Long Beach California 90822, consisting approximately of 1.2 million square feet on a 100-acre lot. All work shall be in accordance with the VALBMC, Local, State, and Federal codes and laws.\nIf you are interested and are capable of providing the sought-out services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n(2) Is your company considered small under the NAICS code identified in this RFI?\n(3) If you are a large business, do you have any designated subcontractors who can perform these services? If so, please provide their company name, telephone, point of Contact and size status (if available).\n(4) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\n(5) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number.\n(6) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the services you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract.\n(7) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award.\n(8) Please submit your capabilities statement illustrating your organization s ability to meet the described statement of work for planning purposes; show clear, compelling and convincing evidence that your organization meets all the requirements in the statement of work.\n(9) Please review statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n(10) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Lorenza.gammage@va.gov. Telephone responses will not be accepted. Responses must be received no later than March 10, 2026, by 10:00 MST.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement.\nResponses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.\nNotice to Potential Offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM).\n\nAdditionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Veteran Small Business (VetCert) located at Veteran Small Business Certification (sba.gov).","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26226Q0377","place_of_performance":{"zip":"90822-5201","street":"Department of Veterans Affairs","country":{"code":"USA","name":"UNITED STATES"},"street2":"Long Beach VA Healthcare System 5901 E. 7th Street"},"product_service_code":"F107"},{"award":{"awardee":{}},"dates":{"posted":"2026-06-10","posted_at":"2026-06-10T20:21:09.816Z","created_at":"2026-06-10T20:21:03.036Z","modified_at":"2026-06-15T17:59:53.488Z","response_deadline":{"raw":"2026-06-16T10:00:00-06:00","utc":"2026-06-16T16:00:00Z","date":"2026-06-16","time":"10:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/87ac12afb9c7474aba576e5ef17cf7dd/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-08-15","archive_type":"auto_custom"},"history":[{"index":4,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-28T20:34:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"eafe5f131f5b4adb820db4f22592b89a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T17:59:53.488Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf2ef133b1e049a08ee95243f9fdb72b","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T20:21:09.816Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd","solicitation_number":"36C26226Q0377"}],"contacts":[{"name":"Lori Gammage","role":"primary","email":"lorenza.gammage@va.gov","phone":"602-795-4135","title":"Contracting Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"87ac12afb9c7474aba576e5ef17cf7dd","lineage_id":"87ac12afb9c7474aba576e5ef17cf7dd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T01:00:28.051246900Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"d0773e87d6d62e5425a99cfa67f4cd13c73b342bc3040c18cee44e6489d1c379","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T01:00:28.051246900Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 13, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought/RFI/RFI only.  The purpose of this Sources Sought/RFI/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 541620 (size standard $19M. Responses to this Sources Sought/RFI/RFI will be used by the Government to make appropriate acquisition decisions.  After reviewing the responses to this Sources Sought/RFI, a solicitation announcement may be published.  Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.  \nThe information identified is intended to be descriptive, not restrictive and to indicate the quality of the services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the services that fulfill the required specifications. \nTibor Rubin VA Medical Center, Long Beach, CA (VALBMC) needs an updated Asbestos, Lead based paint and other Hazardous Materials (ALBHM) survey to assess all buildings for compliance with Veterans Health Administration Directive 7714 (Asbestos Management Plan).  No Phase I Site Assessment has been commissioned in the past 5 years. \nThe survey shall include a visual evaluation and sampling of the following: potential asbestos-containing materials (ACM), lead-based paint, radon gas, PCBs, mercury, and other potentially hazardous materials detailed below. This ALBHM survey will summarize the work conducted; discusses findings regarding the location, quantity, and condition of hazardous materials; and includes recommendations for addressing identified or potential hazards through abatement or management practices.\nThe survey location shall be for all buildings and structures at the Tibor Rubin VA Medical Center located at 5901 East 7th Street, Long Beach California 90822, consisting approximately of 1.2 million square feet on a 100-acre lot. All work shall be in accordance with the VALBMC, Local, State, and Federal codes and laws, and subject to the terms and conditions of this contract.\nA.2 Definitions/Acronyms, Regulatory References, VA References\nAsbestos. Asbestos is a generic term for a number of asbestiform hydrated silicates that, when crushed or processed, separate into flexible fibers made up of fibrils. Asbestos means chrysotile, cummingtonite-grunerite asbestos (amosite), crocidolite, anthophyllite asbestos, tremolite asbestos, and actinolite asbestos. \nAsbestos Containing Construction Materials (ACCM). Specifically refers to materials containing more than 1/10th of 1% (0.1%) asbestos by weight, which triggers specific, strict, and different regulations than the standard >1% definition.\nAsbestos Containing Material (ACM). Any material containing more than 1 percent asbestos. ACM can be divided into three major categories - thermal system insulation, surfacing and miscellaneous.\nAsbestos Containing Building Material (ACBM). Nonfriable suspected asbestos-containing building material, thermal system insulation Asbestos Containing Material (ACM), or miscellaneous ACM that is found in or on the interior structural members or other parts of a building and that when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.\nAsbestos Hazard Emergency Response Act (AHERA). Law required EPA to promulgate regulations (e.g., the Asbestos-Containing Materials in Schools Rule) requiring local educational agencies to inspect their school buildings for asbestos-containing building material, prepare asbestos management plans and perform asbestos response actions to prevent or reduce asbestos hazards.\nAmerican Conference of Governmental Industrial Hygiene (ACGIH). ACGIH develops occupational exposures, Threshold Limit Values (TLVsÂ®), and Biological Exposure Indices (BEIsÂ®) as guidelines to assist in the control of health hazards.\nContracting Officer Representative (COR). A representative for the contracting office ensuring that contractors meet the commitment of their contracts. They facilitate proper development of requirements and assist Contracting Officers in developing and managing their contracts.\nEnvironmental Lead Laboratory Accreditation Program (ELLAP). A program that accredits laboratories performing analysis of lead in environmental samples including paint, soil, dust wipes, composited wipes, and air.\nHeating, Ventilation, Air Conditioning (HVAC). A system that controls the ambient environment (temperature, humidity, airflow and air filtering).\nLead-Based Paint (LBP). Paint or other surface coatings that contain lead equal to or exceeding 1.0 milligram per square centimeter or 0.5 percent by weight or 5,000 parts per million (ppm) by weight.\nMercury and polychlorinated biphenyls (PCBs). PCBs belong to a broad family of man-made organic chemicals known as chlorinated hydrocarbons. PCBs were domestically manufactured from 1929 until manufacturing was banned in 1979. \nNational Lead Laboratory Accreditation Program (NLLAP). An EPA program that defines the minimum requirements and abilities that a laboratory must meet to attain EPA recognition as an accredited lead testing laboratory.\nNational Voluntary Laboratory Accreditation Program (NVLAP). An Agency that provides third-party accreditation to testing and calibration laboratories in response to legislative actions or requests from government agencies or private-sector organizations.\nOccupational Safety and Health Administration (OSHA). A federal agency that establishes on-the-job safety protections for workers\nPermissible Exposure Limit (PEL). Regulatory limit on the amount or concentration of a substance in the air.\nPresumed Asbestos-Containing Material (PACM). Thermal system insulation (TSI) and surfacing material found in a building constructed no later than 1980 or presumed area containing asbestos material.\nRadon is a naturally-occurring radioactive gas that changes into other radioactive substances, called progeny.  Radon is a gas that is colorless and odorless and comes from the natural decay of uranium or thorium, elements found in rocks, soils, and water.\nX-Ray Fluorescence (XRF). A non-destructive analytical technique used to determine the elemental composition of materials.\nA3 Regulatory Overview\nContractor shall be in compliance with all Federal and State Regulations.\nCode of Federal Regulations (CFR): Regulations can be accessed at Law and Regulations | OSHA\n\nB1 Scope of Work\nThe Contractor shall create a survey for results of findings from this contract.  The survey shall include accessible areas of all site buildings and, if present, suspect materials on the interior and exterior of buildings and in basements, penthouses, mechanical spaces, crawl spaces, roofs, to include above ceiling inspection for presence of Asbestos, Lead Based paint and other Hazardous Material (ALBHM). Specific tasks to be performed during the survey shall include but are not limited to the following:\nALBHM: Contractor shall test for the presence of Asbestos, Lead Based paint, and other Hazardous Materials (ALBHM) in all rooms on the survey locations overview B3 :\nAsbestos-containing materials (ACM), i.e.,\nMastic adhesive, TSI, fireproofing, drywall, joint compound, plaster, cement, electrical panels/systems, etc.\ni.e., ACM containing Vinyl Asbestos Tiles\ni.e., ACM containing 12x12 ceiling tiles\ni.e., ACM containing fibers (Roofing) \ni.e., Transite Water and Sewer Pipes\nLead-based paint (LBP)\nsurfaces coated with suspect lead-based paint.\nLead containing ceramic tile glaze.\nHazardous/Universal Waste \nMercury and polychlorinated biphenyls (PCBs) \ni.e., electrical switches and balances\ni.e., HVAC thermostat tilt switches\ni.e., hydraulic and lubricating oils\ni.e., ballasts on fluorescent lights \nRadon Testing\nAll ground-contact rooms, offices, or general use areas\n10% of all upper floor rooms\nContainerized Hazardous Substance\ni.e., HVAC Systems obtaining more than 50lbs of freon\nPotholing survey for soil sample \nSurvey to include soil samples for presence of gasoline range organics (GRO), diesel range organics (DRO), oil range organics (ORO), benzene, toluene, ethylbenzene, and xylenes (BTEX) and lead, Ground Penetrating Radar (GPR), Excavation & Site Potholing.\n\nMaterial Sampling and Handling: \nMaterial Sampling shall follow Section B2.\nThe Contractor shall identify, quantify, and assess all ALBHM and suspect during the survey and categorize each material according to the Asbestos Hazard Emergency Response Act (AHERA) physical and hazard assessment system and AHERA response categories. Inaccessible suspect material shall be noted in the database as presumed ACM and/or ALBHM. These areas of PACM shall be submitted to the VA. The VA will obtain contractor support to allow for testing of PACM as applicable.\nAll Samples shall be transported with a chain of custody to a National Voluntary Laboratory accreditation for program testing. \nThe bulk samples resulting from the survey shall be managed or disposed of by the contractor in accordance with established federal and state rules and regulations.\nAll construction material waste, debris, and any residual sampling material shall be collected, contained, and removed from the site immediately after sampling activities are completed, in compliance with applicable environmental and safety regulations. \n B2 Sampling Procedures \nAsbestos: The Contractor s accredited Building Inspector shall conduct a Physical Assessment that groups all friable and non-friable ACM and suspected ACM in each accessible building space into the following three AHERA homogeneous material categories: Thermal System Insulation (TSI), Surfacing Materials (SM) and Miscellaneous Materials (MM), type (e.g., for TSI    Magnesium silicate,   Aircell,   cork,  etc.), locations, quantities, and conditions of ACM and locations and quantities of presumed ACM present  then sampled in a representative manner in accordance with the appropriate AHERA protocol as necessary when confirmatory testing is needed.\nThe Contractor s accredited Building Inspector shall also conduct a Hazard Assessment in each functional space where friable and non-friable ACM and suspected ACM is present to evaluate the risk posed by each of the following factors: \nAccessibility \nOccupancy (e.g., continuous, intermittent or occasional and patients/staff/visitors), \nPotential for air erosion \nPotential for vibration damage and,\nPotential for disturbance / damage (e.g., exposed and in an accessible location) and (6) Potential for water damage\nAsbestos Samples shall be taken by a certified Site Surveillance Technician (CSST) shall sample under the supervision of a Certified Asbestos Consultant (CAC).\nThe Contractor shall collect all samples of suspected ACM in accordance with EPA and OSHA regulations preventing airborne fiber exposure to the surveyor, patients, visitors and staff. Samples taken in occupied office spaces shall be taken in locations that minimize the risk of potential exposure to occupants and visual impact of the resulting sample location. No sampling of ACM or suspect ACM in occupied areas shall be conducted without first notifying the VA COR, prior to the sampling event. The Contractor is responsible for restoring visible sample locations to a condition as close to original as possible. \nThe Contractor shall encapsulate all locations to prevent any subsequent release of asbestos fibers after sample collection (to include floor tile & mastic locations). The Contractor shall mark sample locations, an exception to this are conspicuous sample locations within occupied areas. The Contractor shall photograph sample locations at the time of sample collection to aid in future identification of sampling location. Prior to the commencement of the physical assessment, the contractor shall provide a current negative exposure assessment for the asbestos bulk sampling operations that are similar to the sampling operations that will be conducted at the Tibor Rubin VA Medical Center, Long Beach, CA (VALBMC). This is required to ensure that the asbestos bulk sampling operations are expected to be consistently below established OSHA permissible exposure limits (PELs). This information will be provided to the COR.\nWhere sampling is required of accessible suspect materials, Building Inspectors shall utilize inconspicuous sample locations and employ methods least destructive to finished surfaces. All destructive samples require VA COR approval prior to performing tasks. Building Inspectors shall use non-destructive means for collecting samples whenever possible.\nDue to possible presence of asbestos in vinyl asbestos tile the contractors must be capable of performing microscopy sampling. \nQuantities of ACM shall be measured wherever practical to minimize the use of estimated material quantities in the final report.\nSample results from the Baseline Asbestos Survey may be utilized in lieu of new sampling based upon the determination of the facility COR.\nRoofing materials, where required, shall be sampled to the extent that they do not compromise the integrity of the roof membrane or void the manufacturer s warranty.\nAll inaccessible or accessible areas (those requiring destructed access such as above plaster ceilings or behind plaster walls or pipe chases) shall be noted in the report and on the CAD drawings. Contractors are not required to, nor allowed to, cut through solid building structures that do not have access openings, in an attempt to reach suspect ACM for visualization and/or sampling. In these cases, contractor shall provide estimated quantities of presumed ACM.\nThe Contractor may implement a stop at first positive strategy of analysis to conserve limited funding resources. \nExcept where it is documented that areas are free of ACM, such as in new construction or areas that have been totally renovated, all accessible building interiors and exteriors shall be visually inspected to identify all friable and non-friable ACM, suspect ACM and presumed ACM.  Examples include but not limited to: B126OP all floors, B126 Kitchen area in the basement, Areas of B126 1st floor such as Phlebotomy and main entrance.\n\nLead Based Paint\nLead based paint (LBP) testing shall be divided into two subcategories: residential and nonresidential buildings. \nBuildings which are owned by the VA and used as a residence shall be comprehensively tested. \nNon-residential buildings owned by the VA shall be tested to identify patterns of LBP.\nThe results will be used by the VA to prepare lead in construction exposure assessments and LBP removal estimates. \nLead samples shall be taken by a California Department of Public Health (CDPH) certified Lead Sampling Technician under the supervision of a certified lead inspector/assessor.\nThe Contractor shall develop a sampling plan (the  Plan ) consistent with the HUD LBP inspection strategies for a multifamily housing development or building sites. The plan shall take into consideration construction and maintenance history. The plan shall determine which surfaces can be grouped together for inspection purposes based on similarity of construction materials and common maintenance histories, how representative surfaces will randomly be tested, and how test results will be statistically evaluated.\nLead surveys will utilize X-Ray testing as a means of establishing homogeneous areas. If necessary, paint chip samples may be collected for laboratory atomic absorption (AA) analysis.\nSuspect LBP shall be tested using an X-Ray Fluorescence (XRF) Analyzer or through the collection of paint chips when XRF results are inconclusive, which shall be analyzed by an American Industrial Hygiene Association (AIHA) accredited analytical laboratory. Testing shall be performed by a Lead Inspector licensed in the state where the facility is located, and who has at least 10 years  experience. Testing shall follow U.S. Housing and Urban Development (HUD) guidelines. \nAll laboratories used for analysis of bulk samples for lead shall have successfully participated in the Environmental Lead Proficiency Analytical Testing Program and shall have accreditation in the National Lead Laboratory Accreditation Program. All bulk sample analysis shall be conducted by laboratories who are accredited under the appropriate program such as: AIHA National Voluntary Laboratory Accreditation Program (NVLAP), or the EPA Environmental Lead Laboratory Accreditation Program (ELLAP), EPA National Lead Laboratory Accreditation Program (NLLAP)\n\nOther Hazardous Materials\nMercury and polychlorinated biphenyls (PCBs).\nThe contractor shall assure a sufficient sample size should be collected to ensure the laboratory can measure the concentrations of PCBs at levels required by the PCB cleanup and disposal regulations per 40 CFR 761.61. \nThe contractor shall adhere to EPA  How to test for PCB and Characterize Suspect Materials :\nBulk solid samples - Bulk solid samples include such materials as caulk, soil, and sand. Bulk solid sampling typically includes removing a small portion of the potentially contaminated material for analytical testing. For example, a caulk sample would be the quantity of caulk needed by the laboratory for analytical testing, removed directly from the suspect area. Take care to ensure that only the caulk is included in the final sample and no other adjacent materials, such as wood or concrete that may skew the sample analysis results. \nWhen soil or sand samples are collected, consider whether the PCBs are on the soil surface or if they could be located deeper in the soil. An example of when PCBs might be on the soil surface would be if fragments of weathered caulking were deposited on undisturbed soil surfaces. Alternatively, PCBs could be located deeper in the soil, in locations such as landscaping areas where the soil surface has been disturbed or where new soil has been added.\n\nNOTE: It is up to the contractor to determine the amount of soil samples needed for this facility in accordance with regulatory requirements regarding sampling methods.  Attached we have provided a site map of the facility as well as approximate locations of the fuel tanks (not to be considered as-built).\nPorous surface samples - Because PCBs can migrate into porous surfaces (e.g., brick, masonry, concrete or wood) surface wipe sampling is not adequate to characterize the PCB concentration of porous surfaces. Instead, core samples should be collected on a bulk basis (i.e., mg/kg) to collect the top 0.5 to 2 cm of the porous surface. For these porous surface samples, an adequate sample (as determined by the analytical laboratory) should be removed for analysis. Tools such as chisels, drills, and saws can be used to collect the sample, taking care to minimize dust generation. The samples should be collected from the top 0.5 cm to 2 cm of the surface closest to the likely source of PCB contamination.\nNon-porous surface samples - If the surface being sampled is smooth and impervious (e.g., unpainted metal surfaces), a hexane-saturated wipe sample can be collected to determine if the surface is contaminated with PCBs. A standard wipe test, as specified in 40 CFR 761.123, uses a 10 cm by 10 cm (or equivalent that equals 100 cm2) template to outline the sample area and a gauze pad or glass wool that has been saturated with hexane to collect the sample. The hexane-saturated wipe is used to thoroughly swab the area inside the 100 cm2 template. Care must be taken to ensure proper use of the sampling template, as the sample results will be based on the 100 cm2 sample area (i.e.,  g per 100 cm2).\nIndoor air samples - Collect indoor air samples in accordance with EPA Methods TO-10A, TO-4A, or equivalent. Sufficient sample volumes, as referenced in the EPA Methods, should be collected to prove a minimum laboratory reporting limit of less than 0.1  g/m3. Consult with the PCB Regional Coordinator for the number of samples to be taken and the type of sampling method to be used. Refer to epa.gov for Regional PCB Programs. \n\nRadon gas\nThe contractor shall take radon samples in 100% of ground contacting rooms unless under regulatory exception (hallways, closets, bathrooms, etc.) and at a minimum of 10% of upper floor rooms.\nRadon gas samples shall be taken by a certified Radon Measurement Professional (RMP) or a certified Radon Measurement Technician (RMT) under the supervision of a RMP.\nTesting of radon gas shall follow the testing procedures and options section of the ANSI/AARST MA-MFLB standards for protocol of conducting measurements of radon and radon decay products in multifamily, school, commercial and mixed used buildings and comply with local and state regulations.\nTesting device shall be utilized in compliance with manufacturers instructions and ANSI/AARST standards. Testing device shall be calibrated prior to use.\nTesting results shall be identified per room if radon mitigation is required per standard. Room result shall be in a pass/fail indication or similar in the testing results of the ALBHM survey report.\n\nHazardous/Universal Waste\nThe Contractor at minimum shall perform a visual inspection of the property building and surrounding areas on the property for the presence of other materials that might be considered hazardous and/or universal wastes. Visual inspection is limited to the following: \nRefrigerants and other ozone-depleting substances, and radioactive \nAny containerized hazardous substance observed at the property was identified, such as 55-gallon drums, petroleum storage containers, aboveground storage tanks, etc. \n\nB3 Survey Locations Overview\nBuildings and Rooms: Refer to LB Site Plan for building locations.\nBldg. 1 (01-0B, 01-0P, 01-01, 01-02, 01-03, 01-04, 01-05)   91,110 SQFT\nBldg. 2 (02-0B, 02-01, 02-02, 02-03)   80,742 SQFT\nBldg. 5 (05-0B, 05-01, 05-02)   36,403 SQFT\nBldg. 5A (5A-0B, 5A-01)   11,774 SQFT\nBldg. 5B   4,434 SQFT\nBldg. 5C   9,641 SQFT\nBldg. 6   12,366 SQFT\nBldg. 7 (07-0B, 07-01, 07-02, 07-03)   35,431 SQFT\nBldg. 8 (08-0B, 08-01, 08-02, 08-03)   35,073 SQFT\nBldg. 43   191 SQFT\nBldg. 48   2,407 SQFT \nBldg. 50   12,676 SQFT\nBldg. 88   1,310 SQFT\nBldg. 126 (126-0B, 126-01, 126-02, 126-03, 126-04, 126-05, 126-06, 126-07, 126-08, 126-09, 126-10, 126-11)   338,112 SQFT\nBldg. 126OP (126OP-0B, 126OP-01, 126OP-02, 126OP-03, 126OP-UP)   81,000 SQFT\nBldg. 136   1,049 SQFT\nBldg. 138 (138-0B, 138-01, 138-02)   61,658 SQFT\nBldg. 149   49,505 SQFT\nBldg. 150 (150-0B, 150-01, 150-02)   140,434 SQFT\nBldg. 151   1,659 SQFT\nBldg. 152   1,182 SQFT\nBldg. 153   300 SQFT\nBldg. 155   630 SQFT\nBldg. 160   5,791 SQFT\nBldg. 161   12,267 SQFT\nBldg. 167T   6,485 SQFT\nBldg. 171   13,847 SQFT\nBldg. 172   290 SQFT\n \nC1 Deliverables\nALBHM Survey Report: Following completion of the field survey and analysis of samples, a survey report shall be prepared and shall include the following:\nNote: The contractor shall provide a separate section for each building, with each building as a subsection to the report.\nAn introduction including a brief description of the buildings, the protocols followed to conduct the survey, findings and recommendations. The Contractor s inspectors shall use unique material location identifiers (using information such as building number, floor, number, room number, compass direction, room surface, sample ID number and material description) to describe Asbestos, Lead Based paint and other Hazardous Materials (ALBHM) and presumed ALBHM locations in the facility that is consistent throughout all reports to promote an ease of comprehension. \nThe Contractor must provide a CD or VA approved flash drive with all data on a summary table spreadsheet. This deliverable must be compatible with ArcGIS. Additionally, it shall capture reported data by building and room numbers. The spreadsheet must include, but not limited to, the following fields:\nSample ID or Sample No\nBuilding [1]\nFloor\nRoom\nSurface Tested [2]\nMaterial Category [3]\nMaterial Tested [4]\nSize\nALBHM Detected [5]\nType of ALBHM [6]\nQuantity\nNumerical priority ranking [6]\nDrawing Number and Photo ID (as applicable)\nFacility Totals at end of table to include each group individually\n[1] Example: B125, 1FL, E120; For all soil samples, contractor shall provide coordinates to show exact location on facility map.\n[2] Example: Floor, Ceiling, Door/Door Frame, Misc, Walls(s), Other (Specify)\n[3] Example: TSI, SM, MM\n[4] Example: Resilient Floor Tile, Plaster, Wood and Metal, Cove Base, Wallboard w Joint Compound, Ceramic Title, Dry wall and Joint Compound, Other (Specify)\n[5] Example: Yes; No, Other (Specify)\n[6] Example: Asbestos, Lead Based Paint, Other (specify)\n[7] Numerical priority ranking as determined by the AHERA-accredited Management Planner from 1-4 for response actions based on the AHERA-accredited Building Inspector s Hazard Assessment findings, where one (1) represents the highest priority (e.g., removal or encapsulation) and (4) represents the lowest priority (6-month O&M surveillance)\nA tabular listing of those surfaces determined to contain, or potentially contain, elevated levels of lead base paint and their locations. \nColor drawings shall be prepared, in an AutoCAD (.dwg vector based) format or similar showing the location of ALBHM as well as sample locations and sample IDs corresponding with summary table on the drawings or similar with VA approval. Initial drawings of buildings will be provided by the VA. Contractor shall submit a layering and key plan that will be approved by the VA. At a minimum ALBHM will be on separate layers and contrast significantly to discern different sampling results:\nLab findings will have a hatch pattern that is color coded base on the findings \nVisual indicators will be straight forward identifying the finding location and category\nThe Result Section of the report shall include a description of the physical condition of the material in question that is appropriate to the survey item (e.g., AHERA categories  Good ,  Damaged  or  Significantly Damaged  in the case of friable ACM). Digital photos shall be used where they help the reader to understand an aspect of the material in questions. The Results Section of the report shall be provided in a spreadsheet format. The Results Section shall at minimum include the following: thumbnail digital pictures, location, type, condition, risk score (1-4), quantity, and comments.\nThe Conclusion Section of the report shall explain how and why the response action recommendations of the report were determined and prioritized.\nAsbestos Management Plan: The Asbestos Management Plan shall include an Operation and Maintenance. Operation and Maintenance plan shall be in compliance with asbestos O&M requirements specified in 40 CFR 763.91 of the AHERA rule.\nC2 Quality Control Plan\nContractor shall establish a quality control plan for all work, including that of his or her subcontractors, to assure compliance with the EPA and State requirements, and ACGIH recommendations. Contractor shall notify appropriate State and/or Federal Environmental Agencies of Asbestos work as required. Contractor shall submit a copy of his/her quality control plan concurrently with the quote. Quality control measures shall include, but are not limited to:\nPerforming all required inspections and tests.\nListing all subcontractors and services they will perform.\nCompliance with applicable Federal, state and local codes and regulations and VHA directives related to conducting the survey. \nParticipation in laboratory quality control programs (e.g., NVLAP, or other appropriate programs recognized by the EPA).\nCorrection of unsatisfactory sampling and testing.\nUse of quality control samples and field blanks\nContractor s Building Inspectors shall use the federal AHERA protocol for bulk sample collection. Surveyors shall each be an AHERA-accredited Building Inspector; Management Planner shall be an AHERA-accredited Management Planner; and asbestos project managers shall be AHERA-accredited Project Designer. Building Inspectors, Management Planners, Project Designers and LBP Inspectors shall have at least 10 years of similar experience with projects of substantially similar size and scope.\nAll laboratories used for analysis of bulk asbestos samples shall be NVLAP-Accredited. Initial analysis will be performed with polarized light microscopy.\nPolarized light microscopy results ranging from less than one (1) percent to ten (10) percent may need additional analysis such as transmission electron microscopy. Therefore, the Contractor shall make arrangements with the laboratory to retain such samples if additional analysis is requested. Additional analysis shall not be completed without prior authorization from the Contracting Officer or the Contracting Officer s designee.\n\nIf you are interested and are capable of providing the sought-out services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n(2) Is your company considered small under the NAICS code identified in this RFI?\n(3) If you are a large business, do you have any designated subcontractors who can perform these services? If so, please provide their company name, telephone, point of Contact and size status (if available).\n(4) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\n(5) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number.\n(6) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the services you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract.\n(7) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award.\n(8) Please submit your capabilities statement illustrating your organization s ability to meet the described salient characteristics for planning purposes; show clear, compelling and convincing evidence that all  equal to items\" meet all the salient characteristics.\n(9) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n(10) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Lorenza.gammage@va.gov. Telephone responses will not be accepted.  Responses must be received no later than June 17, 2026, by 10:00 MST.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement. \nResponses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.\nNotice to Potential Offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM).\n\nAdditionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Veteran Small Business (VetCert) located at Veteran Small Business Certification (sba.gov). \n\nWe will review feedback provided.","text":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 13, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought/RFI/RFI only. The purpose of this Sources Sought/RFI/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 541620 (size standard $19M. Responses to this Sources Sought/RFI/RFI will be used by the Government to make appropriate acquisition decisions. After reviewing the responses to this Sources Sought/RFI, a solicitation announcement may be published. Responses to this Sources Sought/RFI synopsis are not considered adequate responses for a solicitation announcement.\nThe information identified is intended to be descriptive, not restrictive and to indicate the quality of the services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the services that fulfill the required specifications.\nTibor Rubin VA Medical Center, Long Beach, CA (VALBMC) needs an updated Asbestos, Lead based paint and other Hazardous Materials (ALBHM) survey to assess all buildings for compliance with Veterans Health Administration Directive 7714 (Asbestos Management Plan). No Phase I Site Assessment has been commissioned in the past 5 years.\nThe survey shall include a visual evaluation and sampling of the following: potential asbestos-containing materials (ACM), lead-based paint, radon gas, PCBs, mercury, and other potentially hazardous materials detailed below. This ALBHM survey will summarize the work conducted; discusses findings regarding the location, quantity, and condition of hazardous materials; and includes recommendations for addressing identified or potential hazards through abatement or management practices.\nThe survey location shall be for all buildings and structures at the Tibor Rubin VA Medical Center located at 5901 East 7th Street, Long Beach California 90822, consisting approximately of 1.2 million square feet on a 100-acre lot. All work shall be in accordance with the VALBMC, Local, State, and Federal codes and laws, and subject to the terms and conditions of this contract.\nA.2 Definitions/Acronyms, Regulatory References, VA References\nAsbestos. Asbestos is a generic term for a number of asbestiform hydrated silicates that, when crushed or processed, separate into flexible fibers made up of fibrils. Asbestos means chrysotile, cummingtonite-grunerite asbestos (amosite), crocidolite, anthophyllite asbestos, tremolite asbestos, and actinolite asbestos.\nAsbestos Containing Construction Materials (ACCM). Specifically refers to materials containing more than 1/10th of 1% (0.1%) asbestos by weight, which triggers specific, strict, and different regulations than the standard >1% definition.\nAsbestos Containing Material (ACM). Any material containing more than 1 percent asbestos. ACM can be divided into three major categories - thermal system insulation, surfacing and miscellaneous.\nAsbestos Containing Building Material (ACBM). Nonfriable suspected asbestos-containing building material, thermal system insulation Asbestos Containing Material (ACM), or miscellaneous ACM that is found in or on the interior structural members or other parts of a building and that when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.\nAsbestos Hazard Emergency Response Act (AHERA). Law required EPA to promulgate regulations (e.g., the Asbestos-Containing Materials in Schools Rule) requiring local educational agencies to inspect their school buildings for asbestos-containing building material, prepare asbestos management plans and perform asbestos response actions to prevent or reduce asbestos hazards.\nAmerican Conference of Governmental Industrial Hygiene (ACGIH). ACGIH develops occupational exposures, Threshold Limit Values (TLVsÂ®), and Biological Exposure Indices (BEIsÂ®) as guidelines to assist in the control of health hazards.\nContracting Officer Representative (COR). A representative for the contracting office ensuring that contractors meet the commitment of their contracts. They facilitate proper development of requirements and assist Contracting Officers in developing and managing their contracts.\nEnvironmental Lead Laboratory Accreditation Program (ELLAP). A program that accredits laboratories performing analysis of lead in environmental samples including paint, soil, dust wipes, composited wipes, and air.\nHeating, Ventilation, Air Conditioning (HVAC). A system that controls the ambient environment (temperature, humidity, airflow and air filtering).\nLead-Based Paint (LBP). Paint or other surface coatings that contain lead equal to or exceeding 1.0 milligram per square centimeter or 0.5 percent by weight or 5,000 parts per million (ppm) by weight.\nMercury and polychlorinated biphenyls (PCBs). PCBs belong to a broad family of man-made organic chemicals known as chlorinated hydrocarbons. PCBs were domestically manufactured from 1929 until manufacturing was banned in 1979.\nNational Lead Laboratory Accreditation Program (NLLAP). An EPA program that defines the minimum requirements and abilities that a laboratory must meet to attain EPA recognition as an accredited lead testing laboratory.\nNational Voluntary Laboratory Accreditation Program (NVLAP). An Agency that provides third-party accreditation to testing and calibration laboratories in response to legislative actions or requests from government agencies or private-sector organizations.\nOccupational Safety and Health Administration (OSHA). A federal agency that establishes on-the-job safety protections for workers\nPermissible Exposure Limit (PEL). Regulatory limit on the amount or concentration of a substance in the air.\nPresumed Asbestos-Containing Material (PACM). Thermal system insulation (TSI) and surfacing material found in a building constructed no later than 1980 or presumed area containing asbestos material.\nRadon is a naturally-occurring radioactive gas that changes into other radioactive substances, called progeny. Radon is a gas that is colorless and odorless and comes from the natural decay of uranium or thorium, elements found in rocks, soils, and water.\nX-Ray Fluorescence (XRF). A non-destructive analytical technique used to determine the elemental composition of materials.\nA3 Regulatory Overview\nContractor shall be in compliance with all Federal and State Regulations.\nCode of Federal Regulations (CFR): Regulations can be accessed at Law and Regulations | OSHA\n\nB1 Scope of Work\nThe Contractor shall create a survey for results of findings from this contract. The survey shall include accessible areas of all site buildings and, if present, suspect materials on the interior and exterior of buildings and in basements, penthouses, mechanical spaces, crawl spaces, roofs, to include above ceiling inspection for presence of Asbestos, Lead Based paint and other Hazardous Material (ALBHM). Specific tasks to be performed during the survey shall include but are not limited to the following:\nALBHM: Contractor shall test for the presence of Asbestos, Lead Based paint, and other Hazardous Materials (ALBHM) in all rooms on the survey locations overview B3 :\nAsbestos-containing materials (ACM), i.e.,\nMastic adhesive, TSI, fireproofing, drywall, joint compound, plaster, cement, electrical panels/systems, etc.\ni.e., ACM containing Vinyl Asbestos Tiles\ni.e., ACM containing 12x12 ceiling tiles\ni.e., ACM containing fibers (Roofing)\ni.e., Transite Water and Sewer Pipes\nLead-based paint (LBP)\nsurfaces coated with suspect lead-based paint.\nLead containing ceramic tile glaze.\nHazardous/Universal Waste\nMercury and polychlorinated biphenyls (PCBs)\ni.e., electrical switches and balances\ni.e., HVAC thermostat tilt switches\ni.e., hydraulic and lubricating oils\ni.e., ballasts on fluorescent lights\nRadon Testing\nAll ground-contact rooms, offices, or general use areas\n10% of all upper floor rooms\nContainerized Hazardous Substance\ni.e., HVAC Systems obtaining more than 50lbs of freon\nPotholing survey for soil sample\nSurvey to include soil samples for presence of gasoline range organics (GRO), diesel range organics (DRO), oil range organics (ORO), benzene, toluene, ethylbenzene, and xylenes (BTEX) and lead, Ground Penetrating Radar (GPR), Excavation & Site Potholing.\n\nMaterial Sampling and Handling:\nMaterial Sampling shall follow Section B2.\nThe Contractor shall identify, quantify, and assess all ALBHM and suspect during the survey and categorize each material according to the Asbestos Hazard Emergency Response Act (AHERA) physical and hazard assessment system and AHERA response categories. Inaccessible suspect material shall be noted in the database as presumed ACM and/or ALBHM. These areas of PACM shall be submitted to the VA. The VA will obtain contractor support to allow for testing of PACM as applicable.\nAll Samples shall be transported with a chain of custody to a National Voluntary Laboratory accreditation for program testing.\nThe bulk samples resulting from the survey shall be managed or disposed of by the contractor in accordance with established federal and state rules and regulations.\nAll construction material waste, debris, and any residual sampling material shall be collected, contained, and removed from the site immediately after sampling activities are completed, in compliance with applicable environmental and safety regulations.\nB2 Sampling Procedures\nAsbestos: The Contractor s accredited Building Inspector shall conduct a Physical Assessment that groups all friable and non-friable ACM and suspected ACM in each accessible building space into the following three AHERA homogeneous material categories: Thermal System Insulation (TSI), Surfacing Materials (SM) and Miscellaneous Materials (MM), type (e.g., for TSI Magnesium silicate, Aircell, cork, etc.), locations, quantities, and conditions of ACM and locations and quantities of presumed ACM present then sampled in a representative manner in accordance with the appropriate AHERA protocol as necessary when confirmatory testing is needed.\nThe Contractor s accredited Building Inspector shall also conduct a Hazard Assessment in each functional space where friable and non-friable ACM and suspected ACM is present to evaluate the risk posed by each of the following factors:\nAccessibility\nOccupancy (e.g., continuous, intermittent or occasional and patients/staff/visitors),\nPotential for air erosion\nPotential for vibration damage and,\nPotential for disturbance / damage (e.g., exposed and in an accessible location) and (6) Potential for water damage\nAsbestos Samples shall be taken by a certified Site Surveillance Technician (CSST) shall sample under the supervision of a Certified Asbestos Consultant (CAC).\nThe Contractor shall collect all samples of suspected ACM in accordance with EPA and OSHA regulations preventing airborne fiber exposure to the surveyor, patients, visitors and staff. Samples taken in occupied office spaces shall be taken in locations that minimize the risk of potential exposure to occupants and visual impact of the resulting sample location. No sampling of ACM or suspect ACM in occupied areas shall be conducted without first notifying the VA COR, prior to the sampling event. The Contractor is responsible for restoring visible sample locations to a condition as close to original as possible.\nThe Contractor shall encapsulate all locations to prevent any subsequent release of asbestos fibers after sample collection (to include floor tile & mastic locations). The Contractor shall mark sample locations, an exception to this are conspicuous sample locations within occupied areas. The Contractor shall photograph sample locations at the time of sample collection to aid in future identification of sampling location. Prior to the commencement of the physical assessment, the contractor shall provide a current negative exposure assessment for the asbestos bulk sampling operations that are similar to the sampling operations that will be conducted at the Tibor Rubin VA Medical Center, Long Beach, CA (VALBMC). This is required to ensure that the asbestos bulk sampling operations are expected to be consistently below established OSHA permissible exposure limits (PELs). This information will be provided to the COR.\nWhere sampling is required of accessible suspect materials, Building Inspectors shall utilize inconspicuous sample locations and employ methods least destructive to finished surfaces. All destructive samples require VA COR approval prior to performing tasks. Building Inspectors shall use non-destructive means for collecting samples whenever possible.\nDue to possible presence of asbestos in vinyl asbestos tile the contractors must be capable of performing microscopy sampling.\nQuantities of ACM shall be measured wherever practical to minimize the use of estimated material quantities in the final report.\nSample results from the Baseline Asbestos Survey may be utilized in lieu of new sampling based upon the determination of the facility COR.\nRoofing materials, where required, shall be sampled to the extent that they do not compromise the integrity of the roof membrane or void the manufacturer s warranty.\nAll inaccessible or accessible areas (those requiring destructed access such as above plaster ceilings or behind plaster walls or pipe chases) shall be noted in the report and on the CAD drawings. Contractors are not required to, nor allowed to, cut through solid building structures that do not have access openings, in an attempt to reach suspect ACM for visualization and/or sampling. In these cases, contractor shall provide estimated quantities of presumed ACM.\nThe Contractor may implement a stop at first positive strategy of analysis to conserve limited funding resources.\nExcept where it is documented that areas are free of ACM, such as in new construction or areas that have been totally renovated, all accessible building interiors and exteriors shall be visually inspected to identify all friable and non-friable ACM, suspect ACM and presumed ACM. Examples include but not limited to: B126OP all floors, B126 Kitchen area in the basement, Areas of B126 1st floor such as Phlebotomy and main entrance.\n\nLead Based Paint\nLead based paint (LBP) testing shall be divided into two subcategories: residential and nonresidential buildings.\nBuildings which are owned by the VA and used as a residence shall be comprehensively tested.\nNon-residential buildings owned by the VA shall be tested to identify patterns of LBP.\nThe results will be used by the VA to prepare lead in construction exposure assessments and LBP removal estimates.\nLead samples shall be taken by a California Department of Public Health (CDPH) certified Lead Sampling Technician under the supervision of a certified lead inspector/assessor.\nThe Contractor shall develop a sampling plan (the Plan ) consistent with the HUD LBP inspection strategies for a multifamily housing development or building sites. The plan shall take into consideration construction and maintenance history. The plan shall determine which surfaces can be grouped together for inspection purposes based on similarity of construction materials and common maintenance histories, how representative surfaces will randomly be tested, and how test results will be statistically evaluated.\nLead surveys will utilize X-Ray testing as a means of establishing homogeneous areas. If necessary, paint chip samples may be collected for laboratory atomic absorption (AA) analysis.\nSuspect LBP shall be tested using an X-Ray Fluorescence (XRF) Analyzer or through the collection of paint chips when XRF results are inconclusive, which shall be analyzed by an American Industrial Hygiene Association (AIHA) accredited analytical laboratory. Testing shall be performed by a Lead Inspector licensed in the state where the facility is located, and who has at least 10 years experience. Testing shall follow U.S. Housing and Urban Development (HUD) guidelines.\nAll laboratories used for analysis of bulk samples for lead shall have successfully participated in the Environmental Lead Proficiency Analytical Testing Program and shall have accreditation in the National Lead Laboratory Accreditation Program. All bulk sample analysis shall be conducted by laboratories who are accredited under the appropriate program such as: AIHA National Voluntary Laboratory Accreditation Program (NVLAP), or the EPA Environmental Lead Laboratory Accreditation Program (ELLAP), EPA National Lead Laboratory Accreditation Program (NLLAP)\n\nOther Hazardous Materials\nMercury and polychlorinated biphenyls (PCBs).\nThe contractor shall assure a sufficient sample size should be collected to ensure the laboratory can measure the concentrations of PCBs at levels required by the PCB cleanup and disposal regulations per 40 CFR 761.61.\nThe contractor shall adhere to EPA How to test for PCB and Characterize Suspect Materials :\nBulk solid samples - Bulk solid samples include such materials as caulk, soil, and sand. Bulk solid sampling typically includes removing a small portion of the potentially contaminated material for analytical testing. For example, a caulk sample would be the quantity of caulk needed by the laboratory for analytical testing, removed directly from the suspect area. Take care to ensure that only the caulk is included in the final sample and no other adjacent materials, such as wood or concrete that may skew the sample analysis results.\nWhen soil or sand samples are collected, consider whether the PCBs are on the soil surface or if they could be located deeper in the soil. An example of when PCBs might be on the soil surface would be if fragments of weathered caulking were deposited on undisturbed soil surfaces. Alternatively, PCBs could be located deeper in the soil, in locations such as landscaping areas where the soil surface has been disturbed or where new soil has been added.\n\nNOTE: It is up to the contractor to determine the amount of soil samples needed for this facility in accordance with regulatory requirements regarding sampling methods. Attached we have provided a site map of the facility as well as approximate locations of the fuel tanks (not to be considered as-built).\nPorous surface samples - Because PCBs can migrate into porous surfaces (e.g., brick, masonry, concrete or wood) surface wipe sampling is not adequate to characterize the PCB concentration of porous surfaces. Instead, core samples should be collected on a bulk basis (i.e., mg/kg) to collect the top 0.5 to 2 cm of the porous surface. For these porous surface samples, an adequate sample (as determined by the analytical laboratory) should be removed for analysis. Tools such as chisels, drills, and saws can be used to collect the sample, taking care to minimize dust generation. The samples should be collected from the top 0.5 cm to 2 cm of the surface closest to the likely source of PCB contamination.\nNon-porous surface samples - If the surface being sampled is smooth and impervious (e.g., unpainted metal surfaces), a hexane-saturated wipe sample can be collected to determine if the surface is contaminated with PCBs. A standard wipe test, as specified in 40 CFR 761.123, uses a 10 cm by 10 cm (or equivalent that equals 100 cm2) template to outline the sample area and a gauze pad or glass wool that has been saturated with hexane to collect the sample. The hexane-saturated wipe is used to thoroughly swab the area inside the 100 cm2 template. Care must be taken to ensure proper use of the sampling template, as the sample results will be based on the 100 cm2 sample area (i.e., g per 100 cm2).\nIndoor air samples - Collect indoor air samples in accordance with EPA Methods TO-10A, TO-4A, or equivalent. Sufficient sample volumes, as referenced in the EPA Methods, should be collected to prove a minimum laboratory reporting limit of less than 0.1 g/m3. Consult with the PCB Regional Coordinator for the number of samples to be taken and the type of sampling method to be used. Refer to epa.gov for Regional PCB Programs.\n\nRadon gas\nThe contractor shall take radon samples in 100% of ground contacting rooms unless under regulatory exception (hallways, closets, bathrooms, etc.) and at a minimum of 10% of upper floor rooms.\nRadon gas samples shall be taken by a certified Radon Measurement Professional (RMP) or a certified Radon Measurement Technician (RMT) under the supervision of a RMP.\nTesting of radon gas shall follow the testing procedures and options section of the ANSI/AARST MA-MFLB standards for protocol of conducting measurements of radon and radon decay products in multifamily, school, commercial and mixed used buildings and comply with local and state regulations.\nTesting device shall be utilized in compliance with manufacturers instructions and ANSI/AARST standards. Testing device shall be calibrated prior to use.\nTesting results shall be identified per room if radon mitigation is required per standard. Room result shall be in a pass/fail indication or similar in the testing results of the ALBHM survey report.\n\nHazardous/Universal Waste\nThe Contractor at minimum shall perform a visual inspection of the property building and surrounding areas on the property for the presence of other materials that might be considered hazardous and/or universal wastes. Visual inspection is limited to the following:\nRefrigerants and other ozone-depleting substances, and radioactive\nAny containerized hazardous substance observed at the property was identified, such as 55-gallon drums, petroleum storage containers, aboveground storage tanks, etc.\n\nB3 Survey Locations Overview\nBuildings and Rooms: Refer to LB Site Plan for building locations.\nBldg. 1 (01-0B, 01-0P, 01-01, 01-02, 01-03, 01-04, 01-05) 91,110 SQFT\nBldg. 2 (02-0B, 02-01, 02-02, 02-03) 80,742 SQFT\nBldg. 5 (05-0B, 05-01, 05-02) 36,403 SQFT\nBldg. 5A (5A-0B, 5A-01) 11,774 SQFT\nBldg. 5B 4,434 SQFT\nBldg. 5C 9,641 SQFT\nBldg. 6 12,366 SQFT\nBldg. 7 (07-0B, 07-01, 07-02, 07-03) 35,431 SQFT\nBldg. 8 (08-0B, 08-01, 08-02, 08-03) 35,073 SQFT\nBldg. 43 191 SQFT\nBldg. 48 2,407 SQFT\nBldg. 50 12,676 SQFT\nBldg. 88 1,310 SQFT\nBldg. 126 (126-0B, 126-01, 126-02, 126-03, 126-04, 126-05, 126-06, 126-07, 126-08, 126-09, 126-10, 126-11) 338,112 SQFT\nBldg. 126OP (126OP-0B, 126OP-01, 126OP-02, 126OP-03, 126OP-UP) 81,000 SQFT\nBldg. 136 1,049 SQFT\nBldg. 138 (138-0B, 138-01, 138-02) 61,658 SQFT\nBldg. 149 49,505 SQFT\nBldg. 150 (150-0B, 150-01, 150-02) 140,434 SQFT\nBldg. 151 1,659 SQFT\nBldg. 152 1,182 SQFT\nBldg. 153 300 SQFT\nBldg. 155 630 SQFT\nBldg. 160 5,791 SQFT\nBldg. 161 12,267 SQFT\nBldg. 167T 6,485 SQFT\nBldg. 171 13,847 SQFT\nBldg. 172 290 SQFT\n\nC1 Deliverables\nALBHM Survey Report: Following completion of the field survey and analysis of samples, a survey report shall be prepared and shall include the following:\nNote: The contractor shall provide a separate section for each building, with each building as a subsection to the report.\nAn introduction including a brief description of the buildings, the protocols followed to conduct the survey, findings and recommendations. The Contractor s inspectors shall use unique material location identifiers (using information such as building number, floor, number, room number, compass direction, room surface, sample ID number and material description) to describe Asbestos, Lead Based paint and other Hazardous Materials (ALBHM) and presumed ALBHM locations in the facility that is consistent throughout all reports to promote an ease of comprehension.\nThe Contractor must provide a CD or VA approved flash drive with all data on a summary table spreadsheet. This deliverable must be compatible with ArcGIS. Additionally, it shall capture reported data by building and room numbers. The spreadsheet must include, but not limited to, the following fields:\nSample ID or Sample No\nBuilding [1]\nFloor\nRoom\nSurface Tested [2]\nMaterial Category [3]\nMaterial Tested [4]\nSize\nALBHM Detected [5]\nType of ALBHM [6]\nQuantity\nNumerical priority ranking [6]\nDrawing Number and Photo ID (as applicable)\nFacility Totals at end of table to include each group individually\n[1] Example: B125, 1FL, E120; For all soil samples, contractor shall provide coordinates to show exact location on facility map.\n[2] Example: Floor, Ceiling, Door/Door Frame, Misc, Walls(s), Other (Specify)\n[3] Example: TSI, SM, MM\n[4] Example: Resilient Floor Tile, Plaster, Wood and Metal, Cove Base, Wallboard w Joint Compound, Ceramic Title, Dry wall and Joint Compound, Other (Specify)\n[5] Example: Yes; No, Other (Specify)\n[6] Example: Asbestos, Lead Based Paint, Other (specify)\n[7] Numerical priority ranking as determined by the AHERA-accredited Management Planner from 1-4 for response actions based on the AHERA-accredited Building Inspector s Hazard Assessment findings, where one (1) represents the highest priority (e.g., removal or encapsulation) and (4) represents the lowest priority (6-month O&M surveillance)\nA tabular listing of those surfaces determined to contain, or potentially contain, elevated levels of lead base paint and their locations.\nColor drawings shall be prepared, in an AutoCAD (.dwg vector based) format or similar showing the location of ALBHM as well as sample locations and sample IDs corresponding with summary table on the drawings or similar with VA approval. Initial drawings of buildings will be provided by the VA. Contractor shall submit a layering and key plan that will be approved by the VA. At a minimum ALBHM will be on separate layers and contrast significantly to discern different sampling results:\nLab findings will have a hatch pattern that is color coded base on the findings\nVisual indicators will be straight forward identifying the finding location and category\nThe Result Section of the report shall include a description of the physical condition of the material in question that is appropriate to the survey item (e.g., AHERA categories Good , Damaged or Significantly Damaged in the case of friable ACM). Digital photos shall be used where they help the reader to understand an aspect of the material in questions. The Results Section of the report shall be provided in a spreadsheet format. The Results Section shall at minimum include the following: thumbnail digital pictures, location, type, condition, risk score (1-4), quantity, and comments.\nThe Conclusion Section of the report shall explain how and why the response action recommendations of the report were determined and prioritized.\nAsbestos Management Plan: The Asbestos Management Plan shall include an Operation and Maintenance. Operation and Maintenance plan shall be in compliance with asbestos O&M requirements specified in 40 CFR 763.91 of the AHERA rule.\nC2 Quality Control Plan\nContractor shall establish a quality control plan for all work, including that of his or her subcontractors, to assure compliance with the EPA and State requirements, and ACGIH recommendations. Contractor shall notify appropriate State and/or Federal Environmental Agencies of Asbestos work as required. Contractor shall submit a copy of his/her quality control plan concurrently with the quote. Quality control measures shall include, but are not limited to:\nPerforming all required inspections and tests.\nListing all subcontractors and services they will perform.\nCompliance with applicable Federal, state and local codes and regulations and VHA directives related to conducting the survey.\nParticipation in laboratory quality control programs (e.g., NVLAP, or other appropriate programs recognized by the EPA).\nCorrection of unsatisfactory sampling and testing.\nUse of quality control samples and field blanks\nContractor s Building Inspectors shall use the federal AHERA protocol for bulk sample collection. Surveyors shall each be an AHERA-accredited Building Inspector; Management Planner shall be an AHERA-accredited Management Planner; and asbestos project managers shall be AHERA-accredited Project Designer. Building Inspectors, Management Planners, Project Designers and LBP Inspectors shall have at least 10 years of similar experience with projects of substantially similar size and scope.\nAll laboratories used for analysis of bulk asbestos samples shall be NVLAP-Accredited. Initial analysis will be performed with polarized light microscopy.\nPolarized light microscopy results ranging from less than one (1) percent to ten (10) percent may need additional analysis such as transmission electron microscopy. Therefore, the Contractor shall make arrangements with the laboratory to retain such samples if additional analysis is requested. Additional analysis shall not be completed without prior authorization from the Contracting Officer or the Contracting Officer s designee.\n\nIf you are interested and are capable of providing the sought-out services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)?\n(2) Is your company considered small under the NAICS code identified in this RFI?\n(3) If you are a large business, do you have any designated subcontractors who can perform these services? If so, please provide their company name, telephone, point of Contact and size status (if available).\n(4) If you intend to subcontract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to subcontracted work and completion of job.\n(5) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number.\n(6) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the services you are providing information for available on your schedule/contract? Please state if all or some items are available on the contract.\n(7) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award.\n(8) Please submit your capabilities statement illustrating your organization s ability to meet the described salient characteristics for planning purposes; show clear, compelling and convincing evidence that all equal to items\" meet all the salient characteristics.\n(9) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A.\n(10) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Lorenza.gammage@va.gov. Telephone responses will not be accepted. Responses must be received no later than June 17, 2026, by 10:00 MST.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. If a solicitation is issued as a result of the information provided from this RFI, all interested parties must respond to that solicitation separately IAW the specifications of that solicitation announcement.\nResponses to this Sources Sought/RFI notice is not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.\nNotice to Potential Offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM).\n\nAdditionally, all Service-Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Veteran Small Business (VetCert) located at Veteran Small Business Certification (sba.gov).\n\nWe will review feedback provided.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26226Q0377","place_of_performance":{"zip":"90822","city":{"name":"Long Beach"},"state":{"name":"CA"},"street":"Department of Veterans Affairs Tibor Rubin VA Medical Center","street2":"5901 East Seventh Street"},"product_service_code":"F107"},{"award":{"awardee":{}},"dates":{"posted":"2026-06-15","posted_at":"2026-06-15T17:59:53.488Z","created_at":"2026-06-15T17:59:51.243Z","modified_at":"2026-07-28T20:34:27.915Z","response_deadline":{"raw":"2026-06-22T10:00:00-06:00","utc":"2026-06-22T16:00:00Z","date":"2026-06-22","time":"10:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cf2ef133b1e049a08ee95243f9fdb72b/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-08-21","archive_type":"auto_custom"},"history":[{"index":4,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-28T20:34:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"eafe5f131f5b4adb820db4f22592b89a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T17:59:53.488Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf2ef133b1e049a08ee95243f9fdb72b","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T20:21:09.816Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd","solicitation_number":"36C26226Q0377"}],"contacts":[{"name":"Lori Gammage","role":"primary","email":"lorenza.gammage@va.gov","phone":"602-795-4135","title":"Contracting Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"cf2ef133b1e049a08ee95243f9fdb72b","lineage_id":"87ac12afb9c7474aba576e5ef17cf7dd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T00:37:38.185051950Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"c95e00a85b0eb97640ceed72fe023a3f7da5c8e352442e58a3aaa1f7b2c4b062","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T00:37:38.185051950Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"RFI due date has been extended to 6/22/2026 at 10:00 am Pacific Time, due to SAM.gov issues.","text":"RFI due date has been extended to 6/22/2026 at 10:00 am Pacific Time, due to SAM.gov issues.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26226Q0377","product_service_code":"F107"},{"dates":{"posted":"2026-07-28","posted_at":"2026-07-28T20:34:27.915Z","created_at":"2026-07-28T20:33:59.242Z","modified_at":"2026-08-06T21:20:45.857Z","response_deadline":{"raw":"2026-08-12T10:00:00-06:00","utc":"2026-08-12T16:00:00Z","date":"2026-08-12","time":"10:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/eafe5f131f5b4adb820db4f22592b89a/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2026-11-10","archive_type":"auto_custom"},"history":[{"index":4,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-28T20:34:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"eafe5f131f5b4adb820db4f22592b89a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T17:59:53.488Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf2ef133b1e049a08ee95243f9fdb72b","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T20:21:09.816Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd","solicitation_number":"36C26226Q0377"}],"contacts":[{"name":"Lori Gammage","role":"primary","email":"lorenza.gammage@va.gov","phone":"602-795-4135","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"eafe5f131f5b4adb820db4f22592b89a","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"87ac12afb9c7474aba576e5ef17cf7dd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T01:18:38.990913376Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"2df4f0ac6ce2af1a84aff4f58e967ea5967bda32d082b45231c760d523eaf932","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"RFQ 36C26226Q0377","text":"RFQ 36C26226Q0377","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26226Q0377","product_service_code":"F107"},{"dates":{"posted":"2026-08-06","posted_at":"2026-08-06T21:20:45.857Z","created_at":"2026-08-06T21:20:43.266Z","modified_at":"2026-08-06T21:20:45.857Z","response_deadline":{"raw":"2026-08-12T10:00:00-06:00","utc":"2026-08-12T16:00:00Z","date":"2026-08-12","time":"10:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0353a2ca22124c3ba58e31d2f8c46d3a/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-11","archive_type":"auto_custom"},"history":[{"index":5,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-15T14:20:49.361Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"3a9b92fedffd4bdc8db52a58fc349144","solicitation_number":"36C26226Q0377","related_opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a"},{"index":4,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":3,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-28T20:34:27.915Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"eafe5f131f5b4adb820db4f22592b89a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-15T17:59:53.488Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"cf2ef133b1e049a08ee95243f9fdb72b","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services - Updated","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-10T20:21:09.816Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd","solicitation_number":"36C26226Q0377"}],"contacts":[{"name":"Lori Gammage","role":"primary","email":"lorenza.gammage@va.gov","phone":"602-795-4135","title":"Contracting Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"0353a2ca22124c3ba58e31d2f8c46d3a","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"87ac12afb9c7474aba576e5ef17cf7dd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-19T02:28:53.459077594Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"8061b788148b5e53f104e1f04e52e237689ac28394e262922802ecac19ba8b4e","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"36C26225Q1331-S208 Landscape and Lawncare Services\nThe purpose of this amendment is to provide answers to questions submitted by contractors only. \nOffer Date submittal remains the same 8/12/2026 by 10:00 am MDT. \n1. Question: Is there an estimated number of labor days for this project? \nAnswer: Submissions are broken down into 4 phases, roughly 60 days between each for surveying, lab analysis, report production and meeting with the VA. Additional days at the end of phase 4 to compile full report for submission.  \n2. Question: Is there an estimated number of samples required for each type (asbestos, lead, radon, PCB, soil, etc.)? \nAnswer: Radon   Approximately 900 rooms per ANSI-AARST\nContractor to determine sample amounts based on regulations, provided space viewer, and floor plans https://experience.arcgis.com/experience/d57c6a8d262345e6a5ff7384bd852605/page/Buildings-by-Service/\n3. Question: Are there any existing survey reports that can be used for this project? \nAnswer: Yes, an ALBHM 2015 survey of the facility will be provided as guidance. As it has been a decade between survey performed and this current contract, some areas are no longer in use/have been renovated so information may no longer be accurate. \n4. Question: Will there be an on-site preproposal meeting and time to walk through all facilities to determine level of effort and fees?\nAnswer: No, there will not be an on-site proposal meeting, and this is a firm fixed priced contract. \n5. Question: What is the timeline for Q/A and responses? Will the proposal due date be extended?\nAnswer: No, please refer to the instructions per Clause 52.212-1 on page 53. \n6. Question: The Price/Cost schedule does not provide a mechanism to include required services other than ACM scope, such as PCB, Radon, Environmental Site Observation assessment, soil testing, air sampling for PCB...Please advise\nAnswer: The price is based on square footage of the facility, samples are based on CAC, CIH, and regulation requirements for those spaces.  Costs to include laboratory analysis and sample types required.  Contractor to determine what materials to sample. \n7. Question: What is the purpose of the 4 Phases, if they are all the same timeline?\nAnswer: The Price/Cost Schedule on page 5 lists the projected days the work is to be completed. The period of performance start date may vary depending on award of contract, so once contract is awarded Contractor must complete the work based on the total days listed on each of the phases. \nPhases to allow adjustment to this contract and are broken down into administrative spaces first to get a proper cadence of meetings, survey, samplings and notifications prior to more invasive patient occupied spaces of the facility.\n8. Question: How will all of this data be used by the end user?\nAnswer: The Government cannot disclose this information. \n9. Question: How does the end user manage environmental data currently?Â \nAnswer: To ensure facility compliance with VHA Directives and local regulations. Required environmental reports to state and federal authorities.\n10. Question: Radon:Â  in order to assign a value, we need a quantity of rooms.\nAnswer: Approximately 900 samples based on ANSI-AARST standards. \n11. Question: Potholing: WhatÂ does this look like to the VA? Without a Phase I, we are shooting in the dark.Â  In a competitive bid process, there will be a wide-ranging scope without a developed outcome resulting in poor data.Â  We recommend quantifying the number of sample locations, depths and analytes. Alternatively, we would recommend to include a Phase 1 as the base scope and any further exploration would be a contract mod (however, perhaps request a fee per hole for a given depth & analytes up front that can be used to determine the contract mod at a later time, if necessary). \nAnswer: Contractor shall consult with a CIH to determine amount of soil samples needed for our facility.  Contractor shall choose collection method and depth.  Contractor shall ensure to follow the lab s protocol on how samples should be taken and received.\n12: Question: Ground Penetrating Radar:Â What is the purpose and intent of this scope item?Â  Please identify specific area(s) in question as it is doubtful this would be used across the entire site. \nAnswer: Purpose of GPR is to avoid underground utilities when performing soil sampling around the USTs (map provided). Sample for B2 1.3.1.4\n13. Question PCBs in bulk material:Â This can be an extremely costly task item as written and without clarification, there will be a wide range of interpretation and costs.Â  Please identify which buildings, what features and provide a fee structure that is based on a known quantity with a unit cost thereafter.\nAnswer: Contractor shall consult with a CIH to determine the amount to be sampled. Contractor shall ensure to follow the lab s protocol on how samples should be taken and received.\n14. Question: PCB air sampling:Â Similar comment as to the bulk sampling, GPR, soil sampling and radon: Need context and quantification to develop a fee.\nAnswer: See answer 11, 12, and 13 above.\n15 Question: What is the purpose of the UST Map that was part of the solicitation? We didn t see a scope of work for USTs.\nAnswer: Soil sampling as listed in B1. 1.2.6.3.","text":"36C26225Q1331-S208 Landscape and Lawncare Services\nThe purpose of this amendment is to provide answers to questions submitted by contractors only.\nOffer Date submittal remains the same 8/12/2026 by 10:00 am MDT.\n1. Question: Is there an estimated number of labor days for this project?\nAnswer: Submissions are broken down into 4 phases, roughly 60 days between each for surveying, lab analysis, report production and meeting with the VA. Additional days at the end of phase 4 to compile full report for submission.\n2. Question: Is there an estimated number of samples required for each type (asbestos, lead, radon, PCB, soil, etc.)?\nAnswer: Radon Approximately 900 rooms per ANSI-AARST\nContractor to determine sample amounts based on regulations, provided space viewer, and floor plans https://experience.arcgis.com/experience/d57c6a8d262345e6a5ff7384bd852605/page/Buildings-by-Service/\n3. Question: Are there any existing survey reports that can be used for this project?\nAnswer: Yes, an ALBHM 2015 survey of the facility will be provided as guidance. As it has been a decade between survey performed and this current contract, some areas are no longer in use/have been renovated so information may no longer be accurate.\n4. Question: Will there be an on-site preproposal meeting and time to walk through all facilities to determine level of effort and fees?\nAnswer: No, there will not be an on-site proposal meeting, and this is a firm fixed priced contract.\n5. Question: What is the timeline for Q/A and responses? Will the proposal due date be extended?\nAnswer: No, please refer to the instructions per Clause 52.212-1 on page 53.\n6. Question: The Price/Cost schedule does not provide a mechanism to include required services other than ACM scope, such as PCB, Radon, Environmental Site Observation assessment, soil testing, air sampling for PCB...Please advise\nAnswer: The price is based on square footage of the facility, samples are based on CAC, CIH, and regulation requirements for those spaces. Costs to include laboratory analysis and sample types required. Contractor to determine what materials to sample.\n7. Question: What is the purpose of the 4 Phases, if they are all the same timeline?\nAnswer: The Price/Cost Schedule on page 5 lists the projected days the work is to be completed. The period of performance start date may vary depending on award of contract, so once contract is awarded Contractor must complete the work based on the total days listed on each of the phases.\nPhases to allow adjustment to this contract and are broken down into administrative spaces first to get a proper cadence of meetings, survey, samplings and notifications prior to more invasive patient occupied spaces of the facility.\n8. Question: How will all of this data be used by the end user?\nAnswer: The Government cannot disclose this information.\n9. Question: How does the end user manage environmental data currently?Â\nAnswer: To ensure facility compliance with VHA Directives and local regulations. Required environmental reports to state and federal authorities.\n10. Question: Radon:Â in order to assign a value, we need a quantity of rooms.\nAnswer: Approximately 900 samples based on ANSI-AARST standards.\n11. Question: Potholing: WhatÂ does this look like to the VA? Without a Phase I, we are shooting in the dark.Â In a competitive bid process, there will be a wide-ranging scope without a developed outcome resulting in poor data.Â We recommend quantifying the number of sample locations, depths and analytes. Alternatively, we would recommend to include a Phase 1 as the base scope and any further exploration would be a contract mod (however, perhaps request a fee per hole for a given depth & analytes up front that can be used to determine the contract mod at a later time, if necessary).\nAnswer: Contractor shall consult with a CIH to determine amount of soil samples needed for our facility. Contractor shall choose collection method and depth. Contractor shall ensure to follow the lab s protocol on how samples should be taken and received.\n12: Question: Ground Penetrating Radar:Â What is the purpose and intent of this scope item?Â Please identify specific area(s) in question as it is doubtful this would be used across the entire site.\nAnswer: Purpose of GPR is to avoid underground utilities when performing soil sampling around the USTs (map provided). Sample for B2 1.3.1.4\n13. Question PCBs in bulk material:Â This can be an extremely costly task item as written and without clarification, there will be a wide range of interpretation and costs.Â Please identify which buildings, what features and provide a fee structure that is based on a known quantity with a unit cost thereafter.\nAnswer: Contractor shall consult with a CIH to determine the amount to be sampled. Contractor shall ensure to follow the lab s protocol on how samples should be taken and received.\n14. Question: PCB air sampling:Â Similar comment as to the bulk sampling, GPR, soil sampling and radon: Need context and quantification to develop a fee.\nAnswer: See answer 11, 12, and 13 above.\n15 Question: What is the purpose of the UST Map that was part of the solicitation? We didn t see a scope of work for USTs.\nAnswer: Soil sampling as listed in B1. 1.2.6.3.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26226Q0377","place_of_performance":{"street":"Long Beach VA Healthcare System"},"product_service_code":"F107"},{"award":{"date":"2026-09-14","amount":"3407203.00","number":"36C26226C0309","awardee":{"raw":"GDM-AE, Inc. Vancouver WA 98685 USA","uei":"M5UNHELD4R71","cage":"78ZZ5","name":"GDM-AE, Inc.","location":{"zip":"98685","city":{"code":"74060","name":"Vancouver"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-09-15","posted_at":"2026-09-15T14:20:49.361Z","award_date":"2026-09-14","created_at":"2026-09-15T14:15:03.597Z","modified_at":"2026-09-15T14:20:49.366Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/3a9b92fedffd4bdc8db52a58fc349144/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-10-15","archive_type":"auto_custom"},"history":[{"index":2,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-15T14:20:49.361Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"3a9b92fedffd4bdc8db52a58fc349144","solicitation_number":"36C26226Q0377","related_opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a"},{"index":1,"title":"F107--Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-06T21:20:45.857Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0353a2ca22124c3ba58e31d2f8c46d3a","solicitation_number":"36C26226Q0377","parent_opportunity_id":"87ac12afb9c7474aba576e5ef17cf7dd"}],"contacts":[{"name":"Lori Gammage","role":"primary","email":"lorenza.gammage@va.gov","phone":"602-795-4135","title":"Contracting Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"3a9b92fedffd4bdc8db52a58fc349144","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"87ac12afb9c7474aba576e5ef17cf7dd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-23T11:15:41.297523347Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"402f36bcbfbe06d6225e986e6296b5e7cdb023dfad24e0e26dae1f76905a2a7c","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T07:48:43.123177Z"},"description":{"html":"<p>Contract awarded for Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services PoP<br />\n9/21/2026 - 9/20/2027 for the Long Beach VA Healthcare System.&nbsp;</p>","text":"Contract awarded for Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services PoP\n\n9/21/2026 - 9/20/2027 for the Long Beach VA Healthcare System.","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C26226Q0377","place_of_performance":{"zip":"90822","city":{"name":"Long Beach"},"state":{"code":"CA"},"country":{"code":"USA"}},"product_service_code":"F107"}],"due_at":"2026-08-12T16:00:00Z","due_date":"2026-08-12","closes_at":"2026-08-12T16:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"M5UNHELD4R71","amount":"3407203.00","linked_awards":6,"cancelled":false,"archived":true,"updated_at":"2026-10-16T04:37:13.634552Z","principal_notice_id":"3a9b92fedffd4bdc8db52a58fc349144","description":{"text":"Contract awarded for Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services PoP\n\n9/21/2026 - 9/20/2027 for the Long Beach VA Healthcare System.","html":"<p>Contract awarded for Asbestos, Lead Based Paint and other Hazardous Material Survey Testing Services PoP<br />\n9/21/2026 - 9/20/2027 for the Long Beach VA Healthcare System.&nbsp;</p>","origin":"detail"},"contacts":[{"name":"Lori Gammage","role":"primary","email":"lorenza.gammage@va.gov","phone":"602-795-4135","title":"Contracting Specialist"}],"place_of_performance":{"zip":"90822","city":{"name":"Long Beach"},"state":{"code":"CA"},"country":{"code":"USA"}},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"naics_codes":["541380"],"award":{"date":"2026-09-14","amount":"3407203.00","number":"36C26226C0309","awardee":{"raw":"GDM-AE, Inc. Vancouver WA 98685 USA","uei":"M5UNHELD4R71","cage":"78ZZ5","name":"GDM-AE, Inc.","location":{"zip":"98685","city":{"code":"74060","name":"Vancouver"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}}}},"attachments":[{"resource_id":"aeb664abb07d44639481af786f3faab4","name":"36C26226C0309_1.pdf","kind":"file","mime_type":".pdf","size_bytes":246090,"posted_at":"2026-09-15T14:20:49.361Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/aeb664abb07d44639481af786f3faab4/download","mirrored":false},{"resource_id":"e007fb6a32c64bbf80e649d8779b58c5","name":"36C26226Q0377.docx","kind":"file","mime_type":".docx","size_bytes":19379,"posted_at":"2026-03-04T00:05:33.116Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e007fb6a32c64bbf80e649d8779b58c5/download","mirrored":false},{"resource_id":"a355aeb8dd644b39b3fa2db78823826e","name":"36C26226Q0377_4.docx","kind":"file","mime_type":".docx","size_bytes":34222,"posted_at":"2026-06-10T20:21:09.816Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a355aeb8dd644b39b3fa2db78823826e/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C26226C0309_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C26226C0309_3600_-NONE-_-NONE-/","piid":"36C26226C0309","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"M5UNHELD4R71","recipient_name":"GDM-AE, INC.","recipient_uei":"M5UNHELD4R71","recipient_cage":"78ZZ5","recipient_city":"VANCOUVER","recipient_state":"WA","sub_name":"Department of Veterans Affairs","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","office_key":"o-36C262","first_action_date":"2026-09-11","last_action_date":"2026-09-11","actions":1,"obligated":"3407230.00","current_total_value":"3407230.00","potential_total_value":"3407230.00","naics":"541380","psc":"F107","extent_competed":"COMPETED UNDER SAP","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":6,"description":"ASBESTOS TESTING SERVICES","method":"solicitation","confidence":"high","evidence":["solicitation number 36C26226Q0377 equals the FPDS solicitation identifier","same awarding office 36C262"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C26227Q0085","latest_notice_id":"cdde3a94bda84b199f9d3db72af657a6","title":"S215--SDVOSB Furniture Installation Labor Storage - Base Plus Four Option Years | POP: (12/31/2026 - 12/30/2031) |","solicitation_number":"36C26227Q0085","notice_type":"o","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-23","notices":4,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"493190","psc":"S215","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C26227Q0079","latest_notice_id":"00646e7746494ab38ce53bbe9f7e0f59","title":"W065--RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT","solicitation_number":"36C26227Q0079","notice_type":"k","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-26T20:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"532490","psc":"W065","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0139","latest_notice_id":"156fef93406e495486eb1d4e805bb675","title":"6515--PYXIS IV PREP","solicitation_number":"36C26227Q0139","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541519","psc":"6515","set_aside":"SDVOSBC","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26227Q0146","latest_notice_id":"e2fc7d7b106d4b448a5b57cba568ddb4","title":"J041--KITCHEN HOOD PMIR - Base +4 ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0146","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"561790","psc":"J041","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T08:15:06.508374Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open":[{"key":"FA442727Q1009","latest_notice_id":"182e0fcc027e4ae0b87bb2e52b42c8d1","title":"Hot Sticks and Gloves Testing Services, Travis AFB","solicitation_number":"FA442727Q1009","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-01T20:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4427","office_name":"FA4427 60 CONS LGC","naics":"541380","psc":"H259","set_aside":"SBA","state":"CA","county":"06095","county_name":"Solano County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Travis Air Force Base","site_key":"travis-air-force-base-ca","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"SP330027Q0011","latest_notice_id":"45066985ccdb460a8380113ba1f54d04","title":"Cross Connection Hazard Assessment","solicitation_number":"SP330027Q0011","notice_type":"k","first_type":"k","first_posted":"2026-11-06","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-14T17:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SP3300","office_name":"DLA DISTRIBUTION","naics":"541380","psc":"F107","set_aside":"SBA","state":"CA","county":"06077","county_name":"San Joaquin County","city":"0680238","city_name":"Tracy","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":34,"indexable":false}