{"canonical":"https://sealedbidder.com/opportunities/36c26225q1410","key":"36C26225Q1410","url":"https://sealedbidder.com/opportunities/36c26225q1410","title":"7910--Flooring Equipment VAGLA","solicitation_number":"36C26225Q1410","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-09-08T17:00:00Z","first_posted":"2025-08-25","last_posted":"2025-08-25","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"333310","psc":"7910","set_aside":null,"place_state":"CA","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"06037","place_county_name":"Los Angeles County","place_city":"0644000","place_city_name":"Los Angeles","winner":"AANTILIA LLC","award_amount":null,"publications":[{"notice_id":"90e0ea52081f4c55a411516925f4db4c","title":"7910--Flooring Equipment VAGLA","solicitation_number":"36C26225Q1410","notice_type":"k","base_type":"k","posted":"2025-08-25","posted_at":"2025-08-25T20:13:56.015Z","due_at":"2025-09-08T17:00:00Z","due_date":"2025-09-08","cancelled":false,"archived":true,"archive_date":"2025-11-07","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/90e0ea52081f4c55a411516925f4db4c/view","enriched":true,"history":[{"index":3,"title":"7910--Flooring Equipment VAGLA","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T20:13:56.015Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"90e0ea52081f4c55a411516925f4db4c","solicitation_number":"36C26225Q1410"}]}],"latest_notice_id":"90e0ea52081f4c55a411516925f4db4c","first_type":"k","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-08-25","posted_at":"2025-08-25T20:13:56.015Z","created_at":"2025-08-25T20:13:52.558Z","modified_at":"2025-11-07T05:04:27.463Z","response_deadline":{"raw":"2025-09-08T10:00:00-07:00","utc":"2025-09-08T17:00:00Z","date":"2025-09-08","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/90e0ea52081f4c55a411516925f4db4c/view"},"naics":{"codes":["333310"],"primary":"333310"},"title":"7910--Flooring Equipment VAGLA","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-07","archive_type":"auto_custom"},"history":[{"index":3,"title":"7910--Flooring Equipment VAGLA","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-25T20:13:56.015Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"90e0ea52081f4c55a411516925f4db4c","solicitation_number":"36C26225Q1410"}],"contacts":[{"name":"Choo, Sam","role":"primary","email":"Sam.choo@va.gov","phone":"Sam.choo@va.gov","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"90e0ea52081f4c55a411516925f4db4c","lineage_id":"90e0ea52081f4c55a411516925f4db4c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-03T00:55:44.830391126Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8ac930a19c8bc2fef6ebbeb00eaa9413484115ba459fbee8ea4329c5f9847204","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-03T00:55:44.830391126Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"B.2  STATEMENT OF WORK\nINTRODUCTION: The purpose of this Statement of Work (SOW) is to outline the tasks and responsibilities of the vendor in supplying and delivering the following:\nÂ \nSCOPE: VA GLA requests that contractors produce brand name or equivalent products that meet or exceed the physical, functional, and performance requirements of the salient qualities mentioned in this section. The equipment characteristic is vital to meeting the government's technical requirements. The contractor is responsible for both providing and installing equipment.\nÂ \nPHYSICAL CHARACTERISTICS: Equipment must have physical characteristics to enable the government to perform the capabilities:Â \nÂ \nEquipment must meet these requirements (BRAND NAME OR EQUAL):\nClarke Carpet Master 218 Dual Motor Upright Vacuum   Commercial Grade\nMFR PART #: 9060508010\nThe cleaning path must be 18 inches wide for efficient commercial carpet coverage.\nUnit must have dual motors: one dedicated to the vacuum fan and one to the brush for optimal performance.\nMotor power must meet or exceed 1,000 W (combined motor power).\nBrush motor must be at least 200 W and designed for deep carpet agitation.\nVacuum motor must deliver a minimum of 93 CFM airflow and 110 inches of water lift.\nVacuums must include HEPA-level filtration or better, with multi-stage filtration for improved indoor air quality.\nThe filtration system must include a sealed bag system with a bag capacity of 4.2 quarts or higher.\nBrush height must be adjustable to accommodate various carpet pile heights.\nVacuums must include tool-free access to brush rolls and belt for easy maintenance.\nThe power cord must be 50 feet, heavy-duty, and safety yellow, with strain relief.\nUnit must be ETL or UL Listed for operator and facility safety.\nHandle must be ergonomic with fingertip controls and low fatigue grip design.\nMust include onboard accessories: stretch hose, wand, and crevice tool.\nWeight must not exceed 20 lbs., ensuring ease of use for daily commercial cleaning.\nThe operating sound level must be 70 dB(A) or lower, suitable for healthcare or quiet environments.\nMust comply with applicable OSHA and ANSI safety standards.\nDesigned for commercial and institutional use, including healthcare and VA environments.\n\nADVOLUTION(TM) 20XP   Cord Electric Burnishers\nMRF PART #: 01520A\nThe cleaning path (Pad size) must be 20 inches wide for rapid coverage of large floor areas in commercial and healthcare environments.\nMachine (Pad speed) must operate at 2000 RPM or higher, delivering a high-gloss finish on hard floor surfaces.\nThe unit must be equipped with active dust control, including a vacuum motor and dust collection filter or bag.\nMotor must have power output meeting or exceeding 1.5 HP for continuous duty.\nMust include flexible pad driver or floating head design to maintain consistent floor contact across uneven surfaces.\nFrame must be heavy-duty die-cast aluminum or steel, designed for durability and long-term use.\nHandle must be ergonomic and fully adjustable, with fingertip controls and padded grip for operator comfort.\nMust include an integrated safety lock-out switch and circuit breaker to protect against overload.\nPower cord must be 50 feet or longer, 14-gauge, safety yellow, and heavy-duty with strain relief.\nBurnisher must operate at a sound level of 70 dB(A) or lower, suitable for use in noise-sensitive areas.\nTotal machine weight must be 90 lbs. with variation of +/- 5 lbs. to ensure proper pad pressure and polishing performance.\nUnit must include non-marking transport wheels for smooth mobility without scuffing floors.\nMust be UL or ETL Listed, meeting safety certification standards for healthcare and government facility use.\nMust comply with OSHA and ANSI safety codes applicable to powered floor care equipment.\nDesigned for daily or routine floor maintenance in commercial, institutional, and VA medical center settings.\nAll operator maintenance points must be tool-free accessible, including pad driver and dust control components.\n\nES300 XP   Self Contained Carpet Extractors\n\nMFR PART #: 56265500 OR 56265502\nThe cleaning path of the extractor must be 16 inches, designed for medium to large area carpet cleaning.\nThe solution tank must have a minimum capacity of 9 gallons, with a separate recovery tank for dirty water.\nUnit must include a dedicated 10  or longer floor wand kit and compatible hoses for spot cleaning, stairs, and tight areas.\nVacuum motors must deliver 1.5 hp of power or higher, generating strong suction for maximum soil recovery.\nPump pressure must be 120 PSI or higher, ensuring deep penetration of cleaning solution into carpet fibers.\nBrush system must include a motorized roller brush, rotating at sufficient RPM to lift and agitate embedded soil. Brush motor must deliver 1/3 hp of power or higher.\nUnits must allow for separate activation of brush, vacuum, and pump functions for operator control and flexibility.\nRecovery tanks must have an easy-access drain hose or port for hygienic emptying.\nPower cord must be 50 feet or longer, safety-rated, and secured with cord wrap or management feature.\nMust include transport wheels suitable for maneuvering across carpets, tiles, and thresholds.\nSound level must be 70 dB(A) or lower, appropriate for daytime use in occupied healthcare facilities.\nUnit must be ETL, CE, or UL listed for safety compliance in commercial environments.\nCompatible with standard carpet detergents and extractant solutions, with clear chemical intake and rinse system.\nHandle must be adjustable for ergonomic operation and compact storage.\nMust include clear hose visibility for monitoring solution and recovery flow.\nDesigned for commercial and institutional use, including use in VA Medical Centers and large healthcare facilities.\n\nSC450 - Battery Operated Scrubber\n\nMRF PART #: 56383129 OR 56383128 \nThe cleaning path (Scrub width) must be 20 inches, designed for efficient coverage in medium to large areas.\nScrubber must include traction drive for reduced operator fatigue and improved maneuverability.\nSolution tank capacity must be 10.5 gallons or greater, with separate recovery tanks for dirty water. Recovery tank capacity must be 11 gallons or greater.\nRecovery tanks must be equal to or greater than solution tanks and have easy drain access for hygiene and maintenance.\nUnit must come with pad driver compatible with standard 20  floor pads.\nBatteries must be maintenance - free AGM batteries, minimum 2 of the 98 Ah maintenance free (gel) batteries OR 2 of 105 Ah wet batteries.\nMust include an onboard charger compatible with supplied battery configuration.\nBrush/pad pressure must be at least 66 lbs. for effective scrubbing performance.\nScrubbing speed must allow for cleaning productivity of up to 15,000 sq. ft. per hour or more.\nControl panels must be intuitive, waterproof, and provide clear status indicators for battery level.\nUnit must include 24V safety-rated operator controls with shock-proof features (No Shock Risk).\nEquipment must be UL Listed and OSHA/ANSI (Z245.2 or equivalent) compliant for use in healthcare facilities.\nScrubber must include sealed electrical components and corrosion-resistant construction suitable for institutional environments.\nMust have JIC & O-Ring fittings throughout hydraulic system for reliability and serviceability.\nMust include oil sight gauge indicating fluid level and operating temperature where applicable (if hydraulic).\nScrubber must have Ultra High Molecular Weight Polyethylene (UHMW) or similar durable, replaceable guides and wear com- ponents.\nMust have NEMA 4-rated electrical controls, resistant to dust and water pressure for reliable operation in demanding environments.\nMust be designed for quiet operation, with a decibel level below 70 dB(A) to support daytime cleaning in patient care areas.\nIntended for use in VA Medical Centers, hospitals, and institutional cleaning programs.\n\nVL500 75  WET/DRY Vacuums\n\nMRF Model #:  56383408\nVacuum must have an 18-gallon or bigger recovery tank capacity for extended operation without frequent emptying.\nUnit must be designed as a wet/dry vacuum suitable for both liquid and solid debris recovery.\nMust include a front mount squeegee assembly for efficient water pickup over large floor areas.\nMust be supplied with a complete accessory kit, including:\nTube holder\nDrain hose\nAccessory Storage\nAdjustable handle\nFolding Transport Handle\nDust Filter System\nSuction Power at the End of Tube must be 185W or greater delivering strong suction for commercial cleaning applications.\nThe airflow must be   100 CFM and the water lift must be   72 inches, ensuring high-performance wet pickup.\nTank construction must be rotationally molded polyethylene, impact- and corrosion-resistant for long-term durability.\nUnits must feature large rear wheels and front casters for easy mobility across various floor types.\nMust include drain hose or rear drain port for easy emptying of recovery tank without lifting.\nThe power cord must be at least 50 feet, heavy-duty, and grounded for operator safety.\nThe control panel must be clearly labeled and water-resistant, with simple on/off functionality.\nUnit must be UL or ETL Listed, ensuring compliance with applicable safety standards.\nMust comply with OSHA and ANSI standards for use in healthcare and institutional environment.\nSound level must be 82 dB(A) or lower for daytime use in noise-sensitive healthcare areas.\nUnits must be designed for commercial or institutional use, such as in VA hospitals, healthcare, or industrial environments.\nAccessories and components must be easily replaceable, with tool-free access where applicable.\n\nPacesetter 20HD   Floor Machine\n\nMFR Model: 01460A\nThe cleaning path must be 20 inches wide to provide efficient floor coverage in commercial environments.\nMotor must be 1.5 HP or powerful, continuous duty, with overload protection for durability and sustained performance.\nMachine speed must operate at 175 RPM, ideal for stripping, scrubbing, and buffing hard floors.\nMust include a pad driver compatible with standard 20  pads for immediate deployment.\nTransmission must use a triple planetary all-steel gear system for long-term reliability under heavy-duty use.\nFrame must be constructed of die-cast aluminum or steel, offering strength with corrosion resistance.\nThe unit must include a safety lock-out switch and easy-access controls on the handle.\nHandle must be fully adjustable with ergonomic grip and control levers for operator comfort.\nThe power cord must be 50 feet or longer, safety yellow, and industrial grade with strain relief.\nTotal machine weight must be 100 lbs. or more, providing effective pad-to-floor contact pressure.\nMust include non-marking wheels for easy transport without floor damage.\nMust be UL or ETL Listed, compliant with electrical and operator safety standards.\nMachines must be designed for commercial and institutional use, including healthcare and VA facilities.\nMust operate at   70 dB(A) for low-noise environments, suitable for daytime use in occupied areas.\nMust comply with applicable OSHA and ANSI safety standards for floor care equipment.\nAll maintenance points, including belt and brushes, must be easily accessible without special tools.\nFUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the functional and performance capability as listed above in the above. \nÂ \nTRAINING: Contractor is to provide a one-time training at installation of equipment (if applicable). The government will not require additional training.Â \nÂ \nWARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. The government does not accept an extended warranty, which requires advance payment.Â Â Â \nÂ \nPERFORMANCE:Â Â \nAll deliveries and services must be communicated & agreed with VA facility POC prior to execution.\nHours: Normal duty hours are 7:30 a.m. through 5:00 p.m., Monday through Friday, not including federal holidays.Â  Whenever contact with a facility is required outside of normal duty hours, the Contractor shall coordinate these times with the designated COR, POC or designer.Â \nIn accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following national holidays are observed and for the purpose of this contract are defined as  Legal Federal official holidays Â \nNew Year s Day\nJanuary 1st\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nLast Monday in January\nMemorial Day\nLast Monday in January\nJuneteenth\nJune 19th\nIndependence Day\nJuly 4th\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeteran s Day\nNovember 11th\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25th\nNoncontract Charges: The contractor shall not perform any service that will result in additional charges without prior approval from the Contracting Officer.Â \nPayment: Payment will be made upon receipt of a properly prepared invoice which references the period for which payment is due, the contract number and/or assigned purchase order number. The invoice must include the correct payment address.Â \nWaste Removal: The contractor is responsible for removing and properly disposing of all waste related to the services provided on-site at all VA facilities.Â \nFailure to carry out the above procedures will be considered as a failure to document the service visit and will constitute a failure to perform.Â \nAll shipping for parts will be included in the cost of the contract.Â \nÂ \nPLACE OF DELIVERY:Â Â  11301 Wilshire Blvd Los Angeles, CA 90073Â \nÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â \nSECURITYÂ \nInformation SecurityÂ \nThe vendor shall ensure adequate LAN/Internet, data, information, and system security in accordance with VA standard operating procedures and standard contract language, conditions laws, and regulations.Â  The vendor s firewall and web server shall meet or exceed the government s minimum requirements for security.Â  All government data shall be protected behind an approved firewall.Â  Any security violations or attempted violations shall be reported to the VA Project Manager and the VBA Headquarters Information Security Officer as soon as possible.Â  The vendor shall follow all applicable VA policies and procedures governing information security, especially those that pertain to certification accreditation.Â Â \nThe contractor shall follow The Veterans Affair Acquisition Regulation (VAAR) security clause VAAR- 852.273-75  SECURITY REQUIREMENTS FOR UNCLASSIFIED INFORMATION TECHNOLOGY RESOURCES  sited in section C. Contract ClausesÂ \nThe contractor and their personnel shall be subject to the same Federal laws, regulations, standards and VA policies as VA personnel, regarding information and information system security.Â  These include but are not limited to Federal Information Security Management Act (FISMA), Appendix III of OMB Circular A-130, and guidance and standards, available from the Department of Commerce's National Institute of Standards and Technology (NIST).Â  This also includes the use of common security configurations available from NIST's Web site at: http://checklists.nist.gov Â \nTo ensure that appropriate security controls are in place, Contractors must follow the procedures set forth in \"VA Information and Information System Security/Privacy Requirements for IT Contracts\" located at the following Web site: http://www.iprm.oit.va.govÂ \nÂ \nContract Personnel SecurityÂ \nAll contractor employees who require access to the Department of Veterans Affairs' computer systems shall be the subject of a background investigation and must receive a favorable adjudication from the VA Security and Investigations Center (07C).Â  The level of background security investigation will be in accordance with VA Directive 0710 dated September 10, 2004, and is available at: http://www.va.gov/pubs/asp/edsdirec.asp (VA Handbook 0710, Appendix A, Tables 1 - 3).Â  Appropriate Background Investigation (BI) forms will be provided upon contract (or task order) award, and are to be completed and returned to the VA Security and Investigations Center (07C) within 30 days for processing.Â  Contractors will be notified by 07C when the BI has been completed and adjudicated.Â  These requirements are applicable to all subcontractor personnel requiring the same access.Â  If the security clearance investigation is not completed prior to the start date of the contract, the employee may work on the contract while the security clearance is being processed, but the contractor will be responsible for the actions of those individuals they provide to perform work for the VA.Â  In the event that damage arises from work performed by contractor personnel, under the auspices of the contract, the contractor will be responsible for resources necessary to remedy the incident.Â Â \n\nE.2 ADDENDUM to FAR 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES\n  Provisions that are incorporated by reference (by Citation Number, Title, and Date), have the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available.\nThe following provisions are incorporated into 52.212-1 as an addendum to this solicitation:\n1.1 SITE VISIT: Not applicable. \n1.2 SUBMISSION OF OFFERS: Quotes shall be received no later than Monday, September 08, 2025, 10:00 a.m. PST. NO EXTRA TIME WILL BE GIVEN. All quotes must be electronically sent to sam.choo@va.gov. Please reference RFQ 36C26225Q1410 in the subject line. Files should be sent in PDF format and no larger than 10MB or they will be automatically rejected by the server. Vendor shall expect a confirmation e-mail indicating offer was successfully received by the Government. The Government is not responsible for rejected e-mails that exceed the mail capacity. Telephone and fax responses shall NOT be accepted. All offerors must be registered in www.sam.gov to do business with the Government. Ensure your registration is correct, current and has not expired. Vendor must include the SAM UEI number on their quote. Also, for SDVOSB and VOSB verification, please confirm your business is registered with the U.S Small Business Administration at https://veterans.certify.sba.gov/. \n1.3 SUBMISSION OF QUESTIONS: All questions must be received by THURSDAY, August 28, 2025, by 1:00 pm EST. All questions submitted for this solicitation must be electronically sent to sam.choo@va.gov with  RFQ 36C26225Q1410 Question  in the subject line. Questions received after the stated date and time may be addressed at the discretion of the Contracting Officer. \n1.4 DISCUSSIONS WITH OFFERORS: The Government intends to evaluate offers and award a contract without discussions with offerors. Therefore, the offeror's initial offer should contain the offeror's best terms from a price and technical standpoint. However, the Government reserves the right to conduct discussions if later determined by the Contracting Officer to be in the best interest of the Government. The Government may reject any or all offers if such action is in the public interest; accept other than the lowest offer; and waive informalities and minor irregularities in offers received. \n1.5 SUBMISSION OF REQUIRED DOCUMENTS: Submission of Required Documents listed herein is a condition precedent to award of a contract. In general, LIMIT your response to no more than ten (10) type written pages with a 11pt font-size and Arial font-type, including, at a minimum, the following documentation: \n1. SF1449 a. Complete 30a, b and c; Signature, Print Name & Title of Signer, Date Signed \n\n2. B.1 \n\n3. B.3; Unit Price, Amount  \n\n4. E.3\n\n6. E.10 \n\n7. E.12 \n\n8. E.13 \n\n10. SF30 Amendments (If Amendments are issued) a. Complete15a, b and c; Signature, Print Name & Title of Signer, Date Signed \n\n11. Other documents required in accordance with guidance provided in Additional Submissions section below. \n*Electronic Signatures and Dates are acceptable. (or acknowledge via email) \n2. Quote Submission: The contractors shall email electronic portable document format(.pdf) or Microsoft Excel (.xls) format. The quote shall be valid for 60 days. The quote must include allÂ line itemsÂ contained in theÂ solicitation OR will not be accepted for evaluation.\n3. ***Additional Submissions: Offeror must be an authorized dealer, authorized distributor or authorized reseller for the proposed supplies at the time quotes are due. Offeror must submit, WITH ITS QUOTE, an authorization letter or other documents from the OEM demonstrating its  authorized  status that is dated no more than 90 days prior to the date established in this solicitation as the  Submission of Offers  deadline. *F.O. B is Destination, shipping cost must be included in item prices. \n4. Submissions can be sent in multiple emails to avoid computer system email size limitation. Quotes submitted by any other method will not be considered. All proprietary information should be clearly marked. The use of hyperlinks in quotes is prohibited. Late quotes will not be accepted for evaluation unless determined to be in the best interest of the Government. The contractor is responsible for confirming the Government s receipt of the contractor s quote.","text":"B.2 STATEMENT OF WORK\nINTRODUCTION: The purpose of this Statement of Work (SOW) is to outline the tasks and responsibilities of the vendor in supplying and delivering the following:\nÂ\nSCOPE: VA GLA requests that contractors produce brand name or equivalent products that meet or exceed the physical, functional, and performance requirements of the salient qualities mentioned in this section. The equipment characteristic is vital to meeting the government's technical requirements. The contractor is responsible for both providing and installing equipment.\nÂ\nPHYSICAL CHARACTERISTICS: Equipment must have physical characteristics to enable the government to perform the capabilities:Â\nÂ\nEquipment must meet these requirements (BRAND NAME OR EQUAL):\nClarke Carpet Master 218 Dual Motor Upright Vacuum Commercial Grade\nMFR PART #: 9060508010\nThe cleaning path must be 18 inches wide for efficient commercial carpet coverage.\nUnit must have dual motors: one dedicated to the vacuum fan and one to the brush for optimal performance.\nMotor power must meet or exceed 1,000 W (combined motor power).\nBrush motor must be at least 200 W and designed for deep carpet agitation.\nVacuum motor must deliver a minimum of 93 CFM airflow and 110 inches of water lift.\nVacuums must include HEPA-level filtration or better, with multi-stage filtration for improved indoor air quality.\nThe filtration system must include a sealed bag system with a bag capacity of 4.2 quarts or higher.\nBrush height must be adjustable to accommodate various carpet pile heights.\nVacuums must include tool-free access to brush rolls and belt for easy maintenance.\nThe power cord must be 50 feet, heavy-duty, and safety yellow, with strain relief.\nUnit must be ETL or UL Listed for operator and facility safety.\nHandle must be ergonomic with fingertip controls and low fatigue grip design.\nMust include onboard accessories: stretch hose, wand, and crevice tool.\nWeight must not exceed 20 lbs., ensuring ease of use for daily commercial cleaning.\nThe operating sound level must be 70 dB(A) or lower, suitable for healthcare or quiet environments.\nMust comply with applicable OSHA and ANSI safety standards.\nDesigned for commercial and institutional use, including healthcare and VA environments.\n\nADVOLUTION(TM) 20XP Cord Electric Burnishers\nMRF PART #: 01520A\nThe cleaning path (Pad size) must be 20 inches wide for rapid coverage of large floor areas in commercial and healthcare environments.\nMachine (Pad speed) must operate at 2000 RPM or higher, delivering a high-gloss finish on hard floor surfaces.\nThe unit must be equipped with active dust control, including a vacuum motor and dust collection filter or bag.\nMotor must have power output meeting or exceeding 1.5 HP for continuous duty.\nMust include flexible pad driver or floating head design to maintain consistent floor contact across uneven surfaces.\nFrame must be heavy-duty die-cast aluminum or steel, designed for durability and long-term use.\nHandle must be ergonomic and fully adjustable, with fingertip controls and padded grip for operator comfort.\nMust include an integrated safety lock-out switch and circuit breaker to protect against overload.\nPower cord must be 50 feet or longer, 14-gauge, safety yellow, and heavy-duty with strain relief.\nBurnisher must operate at a sound level of 70 dB(A) or lower, suitable for use in noise-sensitive areas.\nTotal machine weight must be 90 lbs. with variation of +/- 5 lbs. to ensure proper pad pressure and polishing performance.\nUnit must include non-marking transport wheels for smooth mobility without scuffing floors.\nMust be UL or ETL Listed, meeting safety certification standards for healthcare and government facility use.\nMust comply with OSHA and ANSI safety codes applicable to powered floor care equipment.\nDesigned for daily or routine floor maintenance in commercial, institutional, and VA medical center settings.\nAll operator maintenance points must be tool-free accessible, including pad driver and dust control components.\n\nES300 XP Self Contained Carpet Extractors\n\nMFR PART #: 56265500 OR 56265502\nThe cleaning path of the extractor must be 16 inches, designed for medium to large area carpet cleaning.\nThe solution tank must have a minimum capacity of 9 gallons, with a separate recovery tank for dirty water.\nUnit must include a dedicated 10 or longer floor wand kit and compatible hoses for spot cleaning, stairs, and tight areas.\nVacuum motors must deliver 1.5 hp of power or higher, generating strong suction for maximum soil recovery.\nPump pressure must be 120 PSI or higher, ensuring deep penetration of cleaning solution into carpet fibers.\nBrush system must include a motorized roller brush, rotating at sufficient RPM to lift and agitate embedded soil. Brush motor must deliver 1/3 hp of power or higher.\nUnits must allow for separate activation of brush, vacuum, and pump functions for operator control and flexibility.\nRecovery tanks must have an easy-access drain hose or port for hygienic emptying.\nPower cord must be 50 feet or longer, safety-rated, and secured with cord wrap or management feature.\nMust include transport wheels suitable for maneuvering across carpets, tiles, and thresholds.\nSound level must be 70 dB(A) or lower, appropriate for daytime use in occupied healthcare facilities.\nUnit must be ETL, CE, or UL listed for safety compliance in commercial environments.\nCompatible with standard carpet detergents and extractant solutions, with clear chemical intake and rinse system.\nHandle must be adjustable for ergonomic operation and compact storage.\nMust include clear hose visibility for monitoring solution and recovery flow.\nDesigned for commercial and institutional use, including use in VA Medical Centers and large healthcare facilities.\n\nSC450 - Battery Operated Scrubber\n\nMRF PART #: 56383129 OR 56383128\nThe cleaning path (Scrub width) must be 20 inches, designed for efficient coverage in medium to large areas.\nScrubber must include traction drive for reduced operator fatigue and improved maneuverability.\nSolution tank capacity must be 10.5 gallons or greater, with separate recovery tanks for dirty water. Recovery tank capacity must be 11 gallons or greater.\nRecovery tanks must be equal to or greater than solution tanks and have easy drain access for hygiene and maintenance.\nUnit must come with pad driver compatible with standard 20 floor pads.\nBatteries must be maintenance - free AGM batteries, minimum 2 of the 98 Ah maintenance free (gel) batteries OR 2 of 105 Ah wet batteries.\nMust include an onboard charger compatible with supplied battery configuration.\nBrush/pad pressure must be at least 66 lbs. for effective scrubbing performance.\nScrubbing speed must allow for cleaning productivity of up to 15,000 sq. ft. per hour or more.\nControl panels must be intuitive, waterproof, and provide clear status indicators for battery level.\nUnit must include 24V safety-rated operator controls with shock-proof features (No Shock Risk).\nEquipment must be UL Listed and OSHA/ANSI (Z245.2 or equivalent) compliant for use in healthcare facilities.\nScrubber must include sealed electrical components and corrosion-resistant construction suitable for institutional environments.\nMust have JIC & O-Ring fittings throughout hydraulic system for reliability and serviceability.\nMust include oil sight gauge indicating fluid level and operating temperature where applicable (if hydraulic).\nScrubber must have Ultra High Molecular Weight Polyethylene (UHMW) or similar durable, replaceable guides and wear com- ponents.\nMust have NEMA 4-rated electrical controls, resistant to dust and water pressure for reliable operation in demanding environments.\nMust be designed for quiet operation, with a decibel level below 70 dB(A) to support daytime cleaning in patient care areas.\nIntended for use in VA Medical Centers, hospitals, and institutional cleaning programs.\n\nVL500 75 WET/DRY Vacuums\n\nMRF Model #: 56383408\nVacuum must have an 18-gallon or bigger recovery tank capacity for extended operation without frequent emptying.\nUnit must be designed as a wet/dry vacuum suitable for both liquid and solid debris recovery.\nMust include a front mount squeegee assembly for efficient water pickup over large floor areas.\nMust be supplied with a complete accessory kit, including:\nTube holder\nDrain hose\nAccessory Storage\nAdjustable handle\nFolding Transport Handle\nDust Filter System\nSuction Power at the End of Tube must be 185W or greater delivering strong suction for commercial cleaning applications.\nThe airflow must be 100 CFM and the water lift must be 72 inches, ensuring high-performance wet pickup.\nTank construction must be rotationally molded polyethylene, impact- and corrosion-resistant for long-term durability.\nUnits must feature large rear wheels and front casters for easy mobility across various floor types.\nMust include drain hose or rear drain port for easy emptying of recovery tank without lifting.\nThe power cord must be at least 50 feet, heavy-duty, and grounded for operator safety.\nThe control panel must be clearly labeled and water-resistant, with simple on/off functionality.\nUnit must be UL or ETL Listed, ensuring compliance with applicable safety standards.\nMust comply with OSHA and ANSI standards for use in healthcare and institutional environment.\nSound level must be 82 dB(A) or lower for daytime use in noise-sensitive healthcare areas.\nUnits must be designed for commercial or institutional use, such as in VA hospitals, healthcare, or industrial environments.\nAccessories and components must be easily replaceable, with tool-free access where applicable.\n\nPacesetter 20HD Floor Machine\n\nMFR Model: 01460A\nThe cleaning path must be 20 inches wide to provide efficient floor coverage in commercial environments.\nMotor must be 1.5 HP or powerful, continuous duty, with overload protection for durability and sustained performance.\nMachine speed must operate at 175 RPM, ideal for stripping, scrubbing, and buffing hard floors.\nMust include a pad driver compatible with standard 20 pads for immediate deployment.\nTransmission must use a triple planetary all-steel gear system for long-term reliability under heavy-duty use.\nFrame must be constructed of die-cast aluminum or steel, offering strength with corrosion resistance.\nThe unit must include a safety lock-out switch and easy-access controls on the handle.\nHandle must be fully adjustable with ergonomic grip and control levers for operator comfort.\nThe power cord must be 50 feet or longer, safety yellow, and industrial grade with strain relief.\nTotal machine weight must be 100 lbs. or more, providing effective pad-to-floor contact pressure.\nMust include non-marking wheels for easy transport without floor damage.\nMust be UL or ETL Listed, compliant with electrical and operator safety standards.\nMachines must be designed for commercial and institutional use, including healthcare and VA facilities.\nMust operate at 70 dB(A) for low-noise environments, suitable for daytime use in occupied areas.\nMust comply with applicable OSHA and ANSI safety standards for floor care equipment.\nAll maintenance points, including belt and brushes, must be easily accessible without special tools.\nFUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the functional and performance capability as listed above in the above.\nÂ\nTRAINING: Contractor is to provide a one-time training at installation of equipment (if applicable). The government will not require additional training.Â\nÂ\nWARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. The government does not accept an extended warranty, which requires advance payment.Â Â Â\nÂ\nPERFORMANCE:Â Â\nAll deliveries and services must be communicated & agreed with VA facility POC prior to execution.\nHours: Normal duty hours are 7:30 a.m. through 5:00 p.m., Monday through Friday, not including federal holidays.Â Whenever contact with a facility is required outside of normal duty hours, the Contractor shall coordinate these times with the designated COR, POC or designer.Â\nIn accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following national holidays are observed and for the purpose of this contract are defined as Legal Federal official holidays Â\nNew Year s Day\nJanuary 1st\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nLast Monday in January\nMemorial Day\nLast Monday in January\nJuneteenth\nJune 19th\nIndependence Day\nJuly 4th\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeteran s Day\nNovember 11th\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25th\nNoncontract Charges: The contractor shall not perform any service that will result in additional charges without prior approval from the Contracting Officer.Â\nPayment: Payment will be made upon receipt of a properly prepared invoice which references the period for which payment is due, the contract number and/or assigned purchase order number. The invoice must include the correct payment address.Â\nWaste Removal: The contractor is responsible for removing and properly disposing of all waste related to the services provided on-site at all VA facilities.Â\nFailure to carry out the above procedures will be considered as a failure to document the service visit and will constitute a failure to perform.Â\nAll shipping for parts will be included in the cost of the contract.Â\nÂ\nPLACE OF DELIVERY:Â Â 11301 Wilshire Blvd Los Angeles, CA 90073Â\nÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â\nSECURITYÂ\nInformation SecurityÂ\nThe vendor shall ensure adequate LAN/Internet, data, information, and system security in accordance with VA standard operating procedures and standard contract language, conditions laws, and regulations.Â The vendor s firewall and web server shall meet or exceed the government s minimum requirements for security.Â All government data shall be protected behind an approved firewall.Â Any security violations or attempted violations shall be reported to the VA Project Manager and the VBA Headquarters Information Security Officer as soon as possible.Â The vendor shall follow all applicable VA policies and procedures governing information security, especially those that pertain to certification accreditation.Â Â\nThe contractor shall follow The Veterans Affair Acquisition Regulation (VAAR) security clause VAAR- 852.273-75 SECURITY REQUIREMENTS FOR UNCLASSIFIED INFORMATION TECHNOLOGY RESOURCES sited in section C. Contract ClausesÂ\nThe contractor and their personnel shall be subject to the same Federal laws, regulations, standards and VA policies as VA personnel, regarding information and information system security.Â These include but are not limited to Federal Information Security Management Act (FISMA), Appendix III of OMB Circular A-130, and guidance and standards, available from the Department of Commerce's National Institute of Standards and Technology (NIST).Â This also includes the use of common security configurations available from NIST's Web site at: http://checklists.nist.gov Â\nTo ensure that appropriate security controls are in place, Contractors must follow the procedures set forth in \"VA Information and Information System Security/Privacy Requirements for IT Contracts\" located at the following Web site: http://www.iprm.oit.va.govÂ\nÂ\nContract Personnel SecurityÂ\nAll contractor employees who require access to the Department of Veterans Affairs' computer systems shall be the subject of a background investigation and must receive a favorable adjudication from the VA Security and Investigations Center (07C).Â The level of background security investigation will be in accordance with VA Directive 0710 dated September 10, 2004, and is available at: http://www.va.gov/pubs/asp/edsdirec.asp (VA Handbook 0710, Appendix A, Tables 1 - 3).Â Appropriate Background Investigation (BI) forms will be provided upon contract (or task order) award, and are to be completed and returned to the VA Security and Investigations Center (07C) within 30 days for processing.Â Contractors will be notified by 07C when the BI has been completed and adjudicated.Â These requirements are applicable to all subcontractor personnel requiring the same access.Â If the security clearance investigation is not completed prior to the start date of the contract, the employee may work on the contract while the security clearance is being processed, but the contractor will be responsible for the actions of those individuals they provide to perform work for the VA.Â In the event that damage arises from work performed by contractor personnel, under the auspices of the contract, the contractor will be responsible for resources necessary to remedy the incident.Â Â\n\nE.2 ADDENDUM to FAR 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES\nProvisions that are incorporated by reference (by Citation Number, Title, and Date), have the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available.\nThe following provisions are incorporated into 52.212-1 as an addendum to this solicitation:\n1.1 SITE VISIT: Not applicable.\n1.2 SUBMISSION OF OFFERS: Quotes shall be received no later than Monday, September 08, 2025, 10:00 a.m. PST. NO EXTRA TIME WILL BE GIVEN. All quotes must be electronically sent to sam.choo@va.gov. Please reference RFQ 36C26225Q1410 in the subject line. Files should be sent in PDF format and no larger than 10MB or they will be automatically rejected by the server. Vendor shall expect a confirmation e-mail indicating offer was successfully received by the Government. The Government is not responsible for rejected e-mails that exceed the mail capacity. Telephone and fax responses shall NOT be accepted. All offerors must be registered in www.sam.gov to do business with the Government. Ensure your registration is correct, current and has not expired. Vendor must include the SAM UEI number on their quote. Also, for SDVOSB and VOSB verification, please confirm your business is registered with the U.S Small Business Administration at https://veterans.certify.sba.gov/.\n1.3 SUBMISSION OF QUESTIONS: All questions must be received by THURSDAY, August 28, 2025, by 1:00 pm EST. All questions submitted for this solicitation must be electronically sent to sam.choo@va.gov with RFQ 36C26225Q1410 Question in the subject line. Questions received after the stated date and time may be addressed at the discretion of the Contracting Officer.\n1.4 DISCUSSIONS WITH OFFERORS: The Government intends to evaluate offers and award a contract without discussions with offerors. Therefore, the offeror's initial offer should contain the offeror's best terms from a price and technical standpoint. However, the Government reserves the right to conduct discussions if later determined by the Contracting Officer to be in the best interest of the Government. The Government may reject any or all offers if such action is in the public interest; accept other than the lowest offer; and waive informalities and minor irregularities in offers received.\n1.5 SUBMISSION OF REQUIRED DOCUMENTS: Submission of Required Documents listed herein is a condition precedent to award of a contract. In general, LIMIT your response to no more than ten (10) type written pages with a 11pt font-size and Arial font-type, including, at a minimum, the following documentation:\n1. SF1449 a. Complete 30a, b and c; Signature, Print Name & Title of Signer, Date Signed\n\n2. B.1\n\n3. B.3; Unit Price, Amount\n\n4. E.3\n\n6. E.10\n\n7. E.12\n\n8. E.13\n\n10. SF30 Amendments (If Amendments are issued) a. Complete15a, b and c; Signature, Print Name & Title of Signer, Date Signed\n\n11. Other documents required in accordance with guidance provided in Additional Submissions section below.\n*Electronic Signatures and Dates are acceptable. (or acknowledge via email)\n2. Quote Submission: The contractors shall email electronic portable document format(.pdf) or Microsoft Excel (.xls) format. The quote shall be valid for 60 days. The quote must include allÂ line itemsÂ contained in theÂ solicitation OR will not be accepted for evaluation.\n3. ***Additional Submissions: Offeror must be an authorized dealer, authorized distributor or authorized reseller for the proposed supplies at the time quotes are due. Offeror must submit, WITH ITS QUOTE, an authorization letter or other documents from the OEM demonstrating its authorized status that is dated no more than 90 days prior to the date established in this solicitation as the Submission of Offers deadline. *F.O. B is Destination, shipping cost must be included in item prices.\n4. Submissions can be sent in multiple emails to avoid computer system email size limitation. Quotes submitted by any other method will not be considered. All proprietary information should be clearly marked. The use of hyperlinks in quotes is prohibited. Late quotes will not be accepted for evaluation unless determined to be in the best interest of the Government. The contractor is responsible for confirming the Government s receipt of the contractor s quote.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C26225Q1410","place_of_performance":{"zip":"90073","city":{"name":"Los Angeles"},"state":{"name":"CA"},"street":"Department of Veterans Affairs 11301 Wilshire Blvd","country":{"code":"USA","name":"UNITED STATES"},"street2":"11301 Wilshire Blvd Warehouse"},"product_service_code":"7910"}],"due_at":"2025-09-08T17:00:00Z","due_date":"2025-09-08","closes_at":"2025-09-08T17:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0644000","city_name":"Los Angeles","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":"M1WNFFFKYSX6","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-11-03T01:38:15.937744Z","principal_notice_id":"90e0ea52081f4c55a411516925f4db4c","description":{"text":"B.2 STATEMENT OF WORK\nINTRODUCTION: The purpose of this Statement of Work (SOW) is to outline the tasks and responsibilities of the vendor in supplying and delivering the following:\nÂ\nSCOPE: VA GLA requests that contractors produce brand name or equivalent products that meet or exceed the physical, functional, and performance requirements of the salient qualities mentioned in this section. The equipment characteristic is vital to meeting the government's technical requirements. The contractor is responsible for both providing and installing equipment.\nÂ\nPHYSICAL CHARACTERISTICS: Equipment must have physical characteristics to enable the government to perform the capabilities:Â\nÂ\nEquipment must meet these requirements (BRAND NAME OR EQUAL):\nClarke Carpet Master 218 Dual Motor Upright Vacuum Commercial Grade\nMFR PART #: 9060508010\nThe cleaning path must be 18 inches wide for efficient commercial carpet coverage.\nUnit must have dual motors: one dedicated to the vacuum fan and one to the brush for optimal performance.\nMotor power must meet or exceed 1,000 W (combined motor power).\nBrush motor must be at least 200 W and designed for deep carpet agitation.\nVacuum motor must deliver a minimum of 93 CFM airflow and 110 inches of water lift.\nVacuums must include HEPA-level filtration or better, with multi-stage filtration for improved indoor air quality.\nThe filtration system must include a sealed bag system with a bag capacity of 4.2 quarts or higher.\nBrush height must be adjustable to accommodate various carpet pile heights.\nVacuums must include tool-free access to brush rolls and belt for easy maintenance.\nThe power cord must be 50 feet, heavy-duty, and safety yellow, with strain relief.\nUnit must be ETL or UL Listed for operator and facility safety.\nHandle must be ergonomic with fingertip controls and low fatigue grip design.\nMust include onboard accessories: stretch hose, wand, and crevice tool.\nWeight must not exceed 20 lbs., ensuring ease of use for daily commercial cleaning.\nThe operating sound level must be 70 dB(A) or lower, suitable for healthcare or quiet environments.\nMust comply with applicable OSHA and ANSI safety standards.\nDesigned for commercial and institutional use, including healthcare and VA environments.\n\nADVOLUTION(TM) 20XP Cord Electric Burnishers\nMRF PART #: 01520A\nThe cleaning path (Pad size) must be 20 inches wide for rapid coverage of large floor areas in commercial and healthcare environments.\nMachine (Pad speed) must operate at 2000 RPM or higher, delivering a high-gloss finish on hard floor surfaces.\nThe unit must be equipped with active dust control, including a vacuum motor and dust collection filter or bag.\nMotor must have power output meeting or exceeding 1.5 HP for continuous duty.\nMust include flexible pad driver or floating head design to maintain consistent floor contact across uneven surfaces.\nFrame must be heavy-duty die-cast aluminum or steel, designed for durability and long-term use.\nHandle must be ergonomic and fully adjustable, with fingertip controls and padded grip for operator comfort.\nMust include an integrated safety lock-out switch and circuit breaker to protect against overload.\nPower cord must be 50 feet or longer, 14-gauge, safety yellow, and heavy-duty with strain relief.\nBurnisher must operate at a sound level of 70 dB(A) or lower, suitable for use in noise-sensitive areas.\nTotal machine weight must be 90 lbs. with variation of +/- 5 lbs. to ensure proper pad pressure and polishing performance.\nUnit must include non-marking transport wheels for smooth mobility without scuffing floors.\nMust be UL or ETL Listed, meeting safety certification standards for healthcare and government facility use.\nMust comply with OSHA and ANSI safety codes applicable to powered floor care equipment.\nDesigned for daily or routine floor maintenance in commercial, institutional, and VA medical center settings.\nAll operator maintenance points must be tool-free accessible, including pad driver and dust control components.\n\nES300 XP Self Contained Carpet Extractors\n\nMFR PART #: 56265500 OR 56265502\nThe cleaning path of the extractor must be 16 inches, designed for medium to large area carpet cleaning.\nThe solution tank must have a minimum capacity of 9 gallons, with a separate recovery tank for dirty water.\nUnit must include a dedicated 10 or longer floor wand kit and compatible hoses for spot cleaning, stairs, and tight areas.\nVacuum motors must deliver 1.5 hp of power or higher, generating strong suction for maximum soil recovery.\nPump pressure must be 120 PSI or higher, ensuring deep penetration of cleaning solution into carpet fibers.\nBrush system must include a motorized roller brush, rotating at sufficient RPM to lift and agitate embedded soil. Brush motor must deliver 1/3 hp of power or higher.\nUnits must allow for separate activation of brush, vacuum, and pump functions for operator control and flexibility.\nRecovery tanks must have an easy-access drain hose or port for hygienic emptying.\nPower cord must be 50 feet or longer, safety-rated, and secured with cord wrap or management feature.\nMust include transport wheels suitable for maneuvering across carpets, tiles, and thresholds.\nSound level must be 70 dB(A) or lower, appropriate for daytime use in occupied healthcare facilities.\nUnit must be ETL, CE, or UL listed for safety compliance in commercial environments.\nCompatible with standard carpet detergents and extractant solutions, with clear chemical intake and rinse system.\nHandle must be adjustable for ergonomic operation and compact storage.\nMust include clear hose visibility for monitoring solution and recovery flow.\nDesigned for commercial and institutional use, including use in VA Medical Centers and large healthcare facilities.\n\nSC450 - Battery Operated Scrubber\n\nMRF PART #: 56383129 OR 56383128\nThe cleaning path (Scrub width) must be 20 inches, designed for efficient coverage in medium to large areas.\nScrubber must include traction drive for reduced operator fatigue and improved maneuverability.\nSolution tank capacity must be 10.5 gallons or greater, with separate recovery tanks for dirty water. Recovery tank capacity must be 11 gallons or greater.\nRecovery tanks must be equal to or greater than solution tanks and have easy drain access for hygiene and maintenance.\nUnit must come with pad driver compatible with standard 20 floor pads.\nBatteries must be maintenance - free AGM batteries, minimum 2 of the 98 Ah maintenance free (gel) batteries OR 2 of 105 Ah wet batteries.\nMust include an onboard charger compatible with supplied battery configuration.\nBrush/pad pressure must be at least 66 lbs. for effective scrubbing performance.\nScrubbing speed must allow for cleaning productivity of up to 15,000 sq. ft. per hour or more.\nControl panels must be intuitive, waterproof, and provide clear status indicators for battery level.\nUnit must include 24V safety-rated operator controls with shock-proof features (No Shock Risk).\nEquipment must be UL Listed and OSHA/ANSI (Z245.2 or equivalent) compliant for use in healthcare facilities.\nScrubber must include sealed electrical components and corrosion-resistant construction suitable for institutional environments.\nMust have JIC & O-Ring fittings throughout hydraulic system for reliability and serviceability.\nMust include oil sight gauge indicating fluid level and operating temperature where applicable (if hydraulic).\nScrubber must have Ultra High Molecular Weight Polyethylene (UHMW) or similar durable, replaceable guides and wear com- ponents.\nMust have NEMA 4-rated electrical controls, resistant to dust and water pressure for reliable operation in demanding environments.\nMust be designed for quiet operation, with a decibel level below 70 dB(A) to support daytime cleaning in patient care areas.\nIntended for use in VA Medical Centers, hospitals, and institutional cleaning programs.\n\nVL500 75 WET/DRY Vacuums\n\nMRF Model #: 56383408\nVacuum must have an 18-gallon or bigger recovery tank capacity for extended operation without frequent emptying.\nUnit must be designed as a wet/dry vacuum suitable for both liquid and solid debris recovery.\nMust include a front mount squeegee assembly for efficient water pickup over large floor areas.\nMust be supplied with a complete accessory kit, including:\nTube holder\nDrain hose\nAccessory Storage\nAdjustable handle\nFolding Transport Handle\nDust Filter System\nSuction Power at the End of Tube must be 185W or greater delivering strong suction for commercial cleaning applications.\nThe airflow must be 100 CFM and the water lift must be 72 inches, ensuring high-performance wet pickup.\nTank construction must be rotationally molded polyethylene, impact- and corrosion-resistant for long-term durability.\nUnits must feature large rear wheels and front casters for easy mobility across various floor types.\nMust include drain hose or rear drain port for easy emptying of recovery tank without lifting.\nThe power cord must be at least 50 feet, heavy-duty, and grounded for operator safety.\nThe control panel must be clearly labeled and water-resistant, with simple on/off functionality.\nUnit must be UL or ETL Listed, ensuring compliance with applicable safety standards.\nMust comply with OSHA and ANSI standards for use in healthcare and institutional environment.\nSound level must be 82 dB(A) or lower for daytime use in noise-sensitive healthcare areas.\nUnits must be designed for commercial or institutional use, such as in VA hospitals, healthcare, or industrial environments.\nAccessories and components must be easily replaceable, with tool-free access where applicable.\n\nPacesetter 20HD Floor Machine\n\nMFR Model: 01460A\nThe cleaning path must be 20 inches wide to provide efficient floor coverage in commercial environments.\nMotor must be 1.5 HP or powerful, continuous duty, with overload protection for durability and sustained performance.\nMachine speed must operate at 175 RPM, ideal for stripping, scrubbing, and buffing hard floors.\nMust include a pad driver compatible with standard 20 pads for immediate deployment.\nTransmission must use a triple planetary all-steel gear system for long-term reliability under heavy-duty use.\nFrame must be constructed of die-cast aluminum or steel, offering strength with corrosion resistance.\nThe unit must include a safety lock-out switch and easy-access controls on the handle.\nHandle must be fully adjustable with ergonomic grip and control levers for operator comfort.\nThe power cord must be 50 feet or longer, safety yellow, and industrial grade with strain relief.\nTotal machine weight must be 100 lbs. or more, providing effective pad-to-floor contact pressure.\nMust include non-marking wheels for easy transport without floor damage.\nMust be UL or ETL Listed, compliant with electrical and operator safety standards.\nMachines must be designed for commercial and institutional use, including healthcare and VA facilities.\nMust operate at 70 dB(A) for low-noise environments, suitable for daytime use in occupied areas.\nMust comply with applicable OSHA and ANSI safety standards for floor care equipment.\nAll maintenance points, including belt and brushes, must be easily accessible without special tools.\nFUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the functional and performance capability as listed above in the above.\nÂ\nTRAINING: Contractor is to provide a one-time training at installation of equipment (if applicable). The government will not require additional training.Â\nÂ\nWARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. The government does not accept an extended warranty, which requires advance payment.Â Â Â\nÂ\nPERFORMANCE:Â Â\nAll deliveries and services must be communicated & agreed with VA facility POC prior to execution.\nHours: Normal duty hours are 7:30 a.m. through 5:00 p.m., Monday through Friday, not including federal holidays.Â Whenever contact with a facility is required outside of normal duty hours, the Contractor shall coordinate these times with the designated COR, POC or designer.Â\nIn accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following national holidays are observed and for the purpose of this contract are defined as Legal Federal official holidays Â\nNew Year s Day\nJanuary 1st\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nLast Monday in January\nMemorial Day\nLast Monday in January\nJuneteenth\nJune 19th\nIndependence Day\nJuly 4th\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeteran s Day\nNovember 11th\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25th\nNoncontract Charges: The contractor shall not perform any service that will result in additional charges without prior approval from the Contracting Officer.Â\nPayment: Payment will be made upon receipt of a properly prepared invoice which references the period for which payment is due, the contract number and/or assigned purchase order number. The invoice must include the correct payment address.Â\nWaste Removal: The contractor is responsible for removing and properly disposing of all waste related to the services provided on-site at all VA facilities.Â\nFailure to carry out the above procedures will be considered as a failure to document the service visit and will constitute a failure to perform.Â\nAll shipping for parts will be included in the cost of the contract.Â\nÂ\nPLACE OF DELIVERY:Â Â 11301 Wilshire Blvd Los Angeles, CA 90073Â\nÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â\nSECURITYÂ\nInformation SecurityÂ\nThe vendor shall ensure adequate LAN/Internet, data, information, and system security in accordance with VA standard operating procedures and standard contract language, conditions laws, and regulations.Â The vendor s firewall and web server shall meet or exceed the government s minimum requirements for security.Â All government data shall be protected behind an approved firewall.Â Any security violations or attempted violations shall be reported to the VA Project Manager and the VBA Headquarters Information Security Officer as soon as possible.Â The vendor shall follow all applicable VA policies and procedures governing information security, especially those that pertain to certification accreditation.Â Â\nThe contractor shall follow The Veterans Affair Acquisition Regulation (VAAR) security clause VAAR- 852.273-75 SECURITY REQUIREMENTS FOR UNCLASSIFIED INFORMATION TECHNOLOGY RESOURCES sited in section C. Contract ClausesÂ\nThe contractor and their personnel shall be subject to the same Federal laws, regulations, standards and VA policies as VA personnel, regarding information and information system security.Â These include but are not limited to Federal Information Security Management Act (FISMA), Appendix III of OMB Circular A-130, and guidance and standards, available from the Department of Commerce's National Institute of Standards and Technology (NIST).Â This also includes the use of common security configurations available from NIST's Web site at: http://checklists.nist.gov Â\nTo ensure that appropriate security controls are in place, Contractors must follow the procedures set forth in \"VA Information and Information System Security/Privacy Requirements for IT Contracts\" located at the following Web site: http://www.iprm.oit.va.govÂ\nÂ\nContract Personnel SecurityÂ\nAll contractor employees who require access to the Department of Veterans Affairs' computer systems shall be the subject of a background investigation and must receive a favorable adjudication from the VA Security and Investigations Center (07C).Â The level of background security investigation will be in accordance with VA Directive 0710 dated September 10, 2004, and is available at: http://www.va.gov/pubs/asp/edsdirec.asp (VA Handbook 0710, Appendix A, Tables 1 - 3).Â Appropriate Background Investigation (BI) forms will be provided upon contract (or task order) award, and are to be completed and returned to the VA Security and Investigations Center (07C) within 30 days for processing.Â Contractors will be notified by 07C when the BI has been completed and adjudicated.Â These requirements are applicable to all subcontractor personnel requiring the same access.Â If the security clearance investigation is not completed prior to the start date of the contract, the employee may work on the contract while the security clearance is being processed, but the contractor will be responsible for the actions of those individuals they provide to perform work for the VA.Â In the event that damage arises from work performed by contractor personnel, under the auspices of the contract, the contractor will be responsible for resources necessary to remedy the incident.Â Â\n\nE.2 ADDENDUM to FAR 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES\nProvisions that are incorporated by reference (by Citation Number, Title, and Date), have the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available.\nThe following provisions are incorporated into 52.212-1 as an addendum to this solicitation:\n1.1 SITE VISIT: Not applicable.\n1.2 SUBMISSION OF OFFERS: Quotes shall be received no later than Monday, September 08, 2025, 10:00 a.m. PST. NO EXTRA TIME WILL BE GIVEN. All quotes must be electronically sent to sam.choo@va.gov. Please reference RFQ 36C26225Q1410 in the subject line. Files should be sent in PDF format and no larger than 10MB or they will be automatically rejected by the server. Vendor shall expect a confirmation e-mail indicating offer was successfully received by the Government. The Government is not responsible for rejected e-mails that exceed the mail capacity. Telephone and fax responses shall NOT be accepted. All offerors must be registered in www.sam.gov to do business with the Government. Ensure your registration is correct, current and has not expired. Vendor must include the SAM UEI number on their quote. Also, for SDVOSB and VOSB verification, please confirm your business is registered with the U.S Small Business Administration at https://veterans.certify.sba.gov/.\n1.3 SUBMISSION OF QUESTIONS: All questions must be received by THURSDAY, August 28, 2025, by 1:00 pm EST. All questions submitted for this solicitation must be electronically sent to sam.choo@va.gov with RFQ 36C26225Q1410 Question in the subject line. Questions received after the stated date and time may be addressed at the discretion of the Contracting Officer.\n1.4 DISCUSSIONS WITH OFFERORS: The Government intends to evaluate offers and award a contract without discussions with offerors. Therefore, the offeror's initial offer should contain the offeror's best terms from a price and technical standpoint. However, the Government reserves the right to conduct discussions if later determined by the Contracting Officer to be in the best interest of the Government. The Government may reject any or all offers if such action is in the public interest; accept other than the lowest offer; and waive informalities and minor irregularities in offers received.\n1.5 SUBMISSION OF REQUIRED DOCUMENTS: Submission of Required Documents listed herein is a condition precedent to award of a contract. In general, LIMIT your response to no more than ten (10) type written pages with a 11pt font-size and Arial font-type, including, at a minimum, the following documentation:\n1. SF1449 a. Complete 30a, b and c; Signature, Print Name & Title of Signer, Date Signed\n\n2. B.1\n\n3. B.3; Unit Price, Amount\n\n4. E.3\n\n6. E.10\n\n7. E.12\n\n8. E.13\n\n10. SF30 Amendments (If Amendments are issued) a. Complete15a, b and c; Signature, Print Name & Title of Signer, Date Signed\n\n11. Other documents required in accordance with guidance provided in Additional Submissions section below.\n*Electronic Signatures and Dates are acceptable. (or acknowledge via email)\n2. Quote Submission: The contractors shall email electronic portable document format(.pdf) or Microsoft Excel (.xls) format. The quote shall be valid for 60 days. The quote must include allÂ line itemsÂ contained in theÂ solicitation OR will not be accepted for evaluation.\n3. ***Additional Submissions: Offeror must be an authorized dealer, authorized distributor or authorized reseller for the proposed supplies at the time quotes are due. Offeror must submit, WITH ITS QUOTE, an authorization letter or other documents from the OEM demonstrating its authorized status that is dated no more than 90 days prior to the date established in this solicitation as the Submission of Offers deadline. *F.O. B is Destination, shipping cost must be included in item prices.\n4. Submissions can be sent in multiple emails to avoid computer system email size limitation. Quotes submitted by any other method will not be considered. All proprietary information should be clearly marked. The use of hyperlinks in quotes is prohibited. Late quotes will not be accepted for evaluation unless determined to be in the best interest of the Government. The contractor is responsible for confirming the Government s receipt of the contractor s quote.","html":"B.2  STATEMENT OF WORK\nINTRODUCTION: The purpose of this Statement of Work (SOW) is to outline the tasks and responsibilities of the vendor in supplying and delivering the following:\nÂ \nSCOPE: VA GLA requests that contractors produce brand name or equivalent products that meet or exceed the physical, functional, and performance requirements of the salient qualities mentioned in this section. The equipment characteristic is vital to meeting the government's technical requirements. The contractor is responsible for both providing and installing equipment.\nÂ \nPHYSICAL CHARACTERISTICS: Equipment must have physical characteristics to enable the government to perform the capabilities:Â \nÂ \nEquipment must meet these requirements (BRAND NAME OR EQUAL):\nClarke Carpet Master 218 Dual Motor Upright Vacuum   Commercial Grade\nMFR PART #: 9060508010\nThe cleaning path must be 18 inches wide for efficient commercial carpet coverage.\nUnit must have dual motors: one dedicated to the vacuum fan and one to the brush for optimal performance.\nMotor power must meet or exceed 1,000 W (combined motor power).\nBrush motor must be at least 200 W and designed for deep carpet agitation.\nVacuum motor must deliver a minimum of 93 CFM airflow and 110 inches of water lift.\nVacuums must include HEPA-level filtration or better, with multi-stage filtration for improved indoor air quality.\nThe filtration system must include a sealed bag system with a bag capacity of 4.2 quarts or higher.\nBrush height must be adjustable to accommodate various carpet pile heights.\nVacuums must include tool-free access to brush rolls and belt for easy maintenance.\nThe power cord must be 50 feet, heavy-duty, and safety yellow, with strain relief.\nUnit must be ETL or UL Listed for operator and facility safety.\nHandle must be ergonomic with fingertip controls and low fatigue grip design.\nMust include onboard accessories: stretch hose, wand, and crevice tool.\nWeight must not exceed 20 lbs., ensuring ease of use for daily commercial cleaning.\nThe operating sound level must be 70 dB(A) or lower, suitable for healthcare or quiet environments.\nMust comply with applicable OSHA and ANSI safety standards.\nDesigned for commercial and institutional use, including healthcare and VA environments.\n\nADVOLUTION(TM) 20XP   Cord Electric Burnishers\nMRF PART #: 01520A\nThe cleaning path (Pad size) must be 20 inches wide for rapid coverage of large floor areas in commercial and healthcare environments.\nMachine (Pad speed) must operate at 2000 RPM or higher, delivering a high-gloss finish on hard floor surfaces.\nThe unit must be equipped with active dust control, including a vacuum motor and dust collection filter or bag.\nMotor must have power output meeting or exceeding 1.5 HP for continuous duty.\nMust include flexible pad driver or floating head design to maintain consistent floor contact across uneven surfaces.\nFrame must be heavy-duty die-cast aluminum or steel, designed for durability and long-term use.\nHandle must be ergonomic and fully adjustable, with fingertip controls and padded grip for operator comfort.\nMust include an integrated safety lock-out switch and circuit breaker to protect against overload.\nPower cord must be 50 feet or longer, 14-gauge, safety yellow, and heavy-duty with strain relief.\nBurnisher must operate at a sound level of 70 dB(A) or lower, suitable for use in noise-sensitive areas.\nTotal machine weight must be 90 lbs. with variation of +/- 5 lbs. to ensure proper pad pressure and polishing performance.\nUnit must include non-marking transport wheels for smooth mobility without scuffing floors.\nMust be UL or ETL Listed, meeting safety certification standards for healthcare and government facility use.\nMust comply with OSHA and ANSI safety codes applicable to powered floor care equipment.\nDesigned for daily or routine floor maintenance in commercial, institutional, and VA medical center settings.\nAll operator maintenance points must be tool-free accessible, including pad driver and dust control components.\n\nES300 XP   Self Contained Carpet Extractors\n\nMFR PART #: 56265500 OR 56265502\nThe cleaning path of the extractor must be 16 inches, designed for medium to large area carpet cleaning.\nThe solution tank must have a minimum capacity of 9 gallons, with a separate recovery tank for dirty water.\nUnit must include a dedicated 10  or longer floor wand kit and compatible hoses for spot cleaning, stairs, and tight areas.\nVacuum motors must deliver 1.5 hp of power or higher, generating strong suction for maximum soil recovery.\nPump pressure must be 120 PSI or higher, ensuring deep penetration of cleaning solution into carpet fibers.\nBrush system must include a motorized roller brush, rotating at sufficient RPM to lift and agitate embedded soil. Brush motor must deliver 1/3 hp of power or higher.\nUnits must allow for separate activation of brush, vacuum, and pump functions for operator control and flexibility.\nRecovery tanks must have an easy-access drain hose or port for hygienic emptying.\nPower cord must be 50 feet or longer, safety-rated, and secured with cord wrap or management feature.\nMust include transport wheels suitable for maneuvering across carpets, tiles, and thresholds.\nSound level must be 70 dB(A) or lower, appropriate for daytime use in occupied healthcare facilities.\nUnit must be ETL, CE, or UL listed for safety compliance in commercial environments.\nCompatible with standard carpet detergents and extractant solutions, with clear chemical intake and rinse system.\nHandle must be adjustable for ergonomic operation and compact storage.\nMust include clear hose visibility for monitoring solution and recovery flow.\nDesigned for commercial and institutional use, including use in VA Medical Centers and large healthcare facilities.\n\nSC450 - Battery Operated Scrubber\n\nMRF PART #: 56383129 OR 56383128 \nThe cleaning path (Scrub width) must be 20 inches, designed for efficient coverage in medium to large areas.\nScrubber must include traction drive for reduced operator fatigue and improved maneuverability.\nSolution tank capacity must be 10.5 gallons or greater, with separate recovery tanks for dirty water. Recovery tank capacity must be 11 gallons or greater.\nRecovery tanks must be equal to or greater than solution tanks and have easy drain access for hygiene and maintenance.\nUnit must come with pad driver compatible with standard 20  floor pads.\nBatteries must be maintenance - free AGM batteries, minimum 2 of the 98 Ah maintenance free (gel) batteries OR 2 of 105 Ah wet batteries.\nMust include an onboard charger compatible with supplied battery configuration.\nBrush/pad pressure must be at least 66 lbs. for effective scrubbing performance.\nScrubbing speed must allow for cleaning productivity of up to 15,000 sq. ft. per hour or more.\nControl panels must be intuitive, waterproof, and provide clear status indicators for battery level.\nUnit must include 24V safety-rated operator controls with shock-proof features (No Shock Risk).\nEquipment must be UL Listed and OSHA/ANSI (Z245.2 or equivalent) compliant for use in healthcare facilities.\nScrubber must include sealed electrical components and corrosion-resistant construction suitable for institutional environments.\nMust have JIC & O-Ring fittings throughout hydraulic system for reliability and serviceability.\nMust include oil sight gauge indicating fluid level and operating temperature where applicable (if hydraulic).\nScrubber must have Ultra High Molecular Weight Polyethylene (UHMW) or similar durable, replaceable guides and wear com- ponents.\nMust have NEMA 4-rated electrical controls, resistant to dust and water pressure for reliable operation in demanding environments.\nMust be designed for quiet operation, with a decibel level below 70 dB(A) to support daytime cleaning in patient care areas.\nIntended for use in VA Medical Centers, hospitals, and institutional cleaning programs.\n\nVL500 75  WET/DRY Vacuums\n\nMRF Model #:  56383408\nVacuum must have an 18-gallon or bigger recovery tank capacity for extended operation without frequent emptying.\nUnit must be designed as a wet/dry vacuum suitable for both liquid and solid debris recovery.\nMust include a front mount squeegee assembly for efficient water pickup over large floor areas.\nMust be supplied with a complete accessory kit, including:\nTube holder\nDrain hose\nAccessory Storage\nAdjustable handle\nFolding Transport Handle\nDust Filter System\nSuction Power at the End of Tube must be 185W or greater delivering strong suction for commercial cleaning applications.\nThe airflow must be   100 CFM and the water lift must be   72 inches, ensuring high-performance wet pickup.\nTank construction must be rotationally molded polyethylene, impact- and corrosion-resistant for long-term durability.\nUnits must feature large rear wheels and front casters for easy mobility across various floor types.\nMust include drain hose or rear drain port for easy emptying of recovery tank without lifting.\nThe power cord must be at least 50 feet, heavy-duty, and grounded for operator safety.\nThe control panel must be clearly labeled and water-resistant, with simple on/off functionality.\nUnit must be UL or ETL Listed, ensuring compliance with applicable safety standards.\nMust comply with OSHA and ANSI standards for use in healthcare and institutional environment.\nSound level must be 82 dB(A) or lower for daytime use in noise-sensitive healthcare areas.\nUnits must be designed for commercial or institutional use, such as in VA hospitals, healthcare, or industrial environments.\nAccessories and components must be easily replaceable, with tool-free access where applicable.\n\nPacesetter 20HD   Floor Machine\n\nMFR Model: 01460A\nThe cleaning path must be 20 inches wide to provide efficient floor coverage in commercial environments.\nMotor must be 1.5 HP or powerful, continuous duty, with overload protection for durability and sustained performance.\nMachine speed must operate at 175 RPM, ideal for stripping, scrubbing, and buffing hard floors.\nMust include a pad driver compatible with standard 20  pads for immediate deployment.\nTransmission must use a triple planetary all-steel gear system for long-term reliability under heavy-duty use.\nFrame must be constructed of die-cast aluminum or steel, offering strength with corrosion resistance.\nThe unit must include a safety lock-out switch and easy-access controls on the handle.\nHandle must be fully adjustable with ergonomic grip and control levers for operator comfort.\nThe power cord must be 50 feet or longer, safety yellow, and industrial grade with strain relief.\nTotal machine weight must be 100 lbs. or more, providing effective pad-to-floor contact pressure.\nMust include non-marking wheels for easy transport without floor damage.\nMust be UL or ETL Listed, compliant with electrical and operator safety standards.\nMachines must be designed for commercial and institutional use, including healthcare and VA facilities.\nMust operate at   70 dB(A) for low-noise environments, suitable for daytime use in occupied areas.\nMust comply with applicable OSHA and ANSI safety standards for floor care equipment.\nAll maintenance points, including belt and brushes, must be easily accessible without special tools.\nFUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Equipment must provide the functional and performance capability as listed above in the above. \nÂ \nTRAINING: Contractor is to provide a one-time training at installation of equipment (if applicable). The government will not require additional training.Â \nÂ \nWARRANTY OF EQUIPMENT: Government requirement for standard manufacturer industry warranty term. The government does not accept an extended warranty, which requires advance payment.Â Â Â \nÂ \nPERFORMANCE:Â Â \nAll deliveries and services must be communicated & agreed with VA facility POC prior to execution.\nHours: Normal duty hours are 7:30 a.m. through 5:00 p.m., Monday through Friday, not including federal holidays.Â  Whenever contact with a facility is required outside of normal duty hours, the Contractor shall coordinate these times with the designated COR, POC or designer.Â \nIn accordance with 5 U.S.C. 6103, Executive Order 11582 and Public Law 94-97 the following national holidays are observed and for the purpose of this contract are defined as  Legal Federal official holidays Â \nNew Year s Day\nJanuary 1st\nMartin Luther King s Birthday\nThird Monday in January\nPresident s Day\nLast Monday in January\nMemorial Day\nLast Monday in January\nJuneteenth\nJune 19th\nIndependence Day\nJuly 4th\nLabor Day\nFirst Monday in September\nColumbus Day\nSecond Monday in October\nVeteran s Day\nNovember 11th\nThanksgiving Day\nFourth Thursday in November\nChristmas Day\nDecember 25th\nNoncontract Charges: The contractor shall not perform any service that will result in additional charges without prior approval from the Contracting Officer.Â \nPayment: Payment will be made upon receipt of a properly prepared invoice which references the period for which payment is due, the contract number and/or assigned purchase order number. The invoice must include the correct payment address.Â \nWaste Removal: The contractor is responsible for removing and properly disposing of all waste related to the services provided on-site at all VA facilities.Â \nFailure to carry out the above procedures will be considered as a failure to document the service visit and will constitute a failure to perform.Â \nAll shipping for parts will be included in the cost of the contract.Â \nÂ \nPLACE OF DELIVERY:Â Â  11301 Wilshire Blvd Los Angeles, CA 90073Â \nÂ Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â \nSECURITYÂ \nInformation SecurityÂ \nThe vendor shall ensure adequate LAN/Internet, data, information, and system security in accordance with VA standard operating procedures and standard contract language, conditions laws, and regulations.Â  The vendor s firewall and web server shall meet or exceed the government s minimum requirements for security.Â  All government data shall be protected behind an approved firewall.Â  Any security violations or attempted violations shall be reported to the VA Project Manager and the VBA Headquarters Information Security Officer as soon as possible.Â  The vendor shall follow all applicable VA policies and procedures governing information security, especially those that pertain to certification accreditation.Â Â \nThe contractor shall follow The Veterans Affair Acquisition Regulation (VAAR) security clause VAAR- 852.273-75  SECURITY REQUIREMENTS FOR UNCLASSIFIED INFORMATION TECHNOLOGY RESOURCES  sited in section C. Contract ClausesÂ \nThe contractor and their personnel shall be subject to the same Federal laws, regulations, standards and VA policies as VA personnel, regarding information and information system security.Â  These include but are not limited to Federal Information Security Management Act (FISMA), Appendix III of OMB Circular A-130, and guidance and standards, available from the Department of Commerce's National Institute of Standards and Technology (NIST).Â  This also includes the use of common security configurations available from NIST's Web site at: http://checklists.nist.gov Â \nTo ensure that appropriate security controls are in place, Contractors must follow the procedures set forth in \"VA Information and Information System Security/Privacy Requirements for IT Contracts\" located at the following Web site: http://www.iprm.oit.va.govÂ \nÂ \nContract Personnel SecurityÂ \nAll contractor employees who require access to the Department of Veterans Affairs' computer systems shall be the subject of a background investigation and must receive a favorable adjudication from the VA Security and Investigations Center (07C).Â  The level of background security investigation will be in accordance with VA Directive 0710 dated September 10, 2004, and is available at: http://www.va.gov/pubs/asp/edsdirec.asp (VA Handbook 0710, Appendix A, Tables 1 - 3).Â  Appropriate Background Investigation (BI) forms will be provided upon contract (or task order) award, and are to be completed and returned to the VA Security and Investigations Center (07C) within 30 days for processing.Â  Contractors will be notified by 07C when the BI has been completed and adjudicated.Â  These requirements are applicable to all subcontractor personnel requiring the same access.Â  If the security clearance investigation is not completed prior to the start date of the contract, the employee may work on the contract while the security clearance is being processed, but the contractor will be responsible for the actions of those individuals they provide to perform work for the VA.Â  In the event that damage arises from work performed by contractor personnel, under the auspices of the contract, the contractor will be responsible for resources necessary to remedy the incident.Â Â \n\nE.2 ADDENDUM to FAR 52.212-1 INSTRUCTIONS TO OFFERORS COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES\n  Provisions that are incorporated by reference (by Citation Number, Title, and Date), have the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available.\nThe following provisions are incorporated into 52.212-1 as an addendum to this solicitation:\n1.1 SITE VISIT: Not applicable. \n1.2 SUBMISSION OF OFFERS: Quotes shall be received no later than Monday, September 08, 2025, 10:00 a.m. PST. NO EXTRA TIME WILL BE GIVEN. All quotes must be electronically sent to sam.choo@va.gov. Please reference RFQ 36C26225Q1410 in the subject line. Files should be sent in PDF format and no larger than 10MB or they will be automatically rejected by the server. Vendor shall expect a confirmation e-mail indicating offer was successfully received by the Government. The Government is not responsible for rejected e-mails that exceed the mail capacity. Telephone and fax responses shall NOT be accepted. All offerors must be registered in www.sam.gov to do business with the Government. Ensure your registration is correct, current and has not expired. Vendor must include the SAM UEI number on their quote. Also, for SDVOSB and VOSB verification, please confirm your business is registered with the U.S Small Business Administration at https://veterans.certify.sba.gov/. \n1.3 SUBMISSION OF QUESTIONS: All questions must be received by THURSDAY, August 28, 2025, by 1:00 pm EST. All questions submitted for this solicitation must be electronically sent to sam.choo@va.gov with  RFQ 36C26225Q1410 Question  in the subject line. Questions received after the stated date and time may be addressed at the discretion of the Contracting Officer. \n1.4 DISCUSSIONS WITH OFFERORS: The Government intends to evaluate offers and award a contract without discussions with offerors. Therefore, the offeror's initial offer should contain the offeror's best terms from a price and technical standpoint. However, the Government reserves the right to conduct discussions if later determined by the Contracting Officer to be in the best interest of the Government. The Government may reject any or all offers if such action is in the public interest; accept other than the lowest offer; and waive informalities and minor irregularities in offers received. \n1.5 SUBMISSION OF REQUIRED DOCUMENTS: Submission of Required Documents listed herein is a condition precedent to award of a contract. In general, LIMIT your response to no more than ten (10) type written pages with a 11pt font-size and Arial font-type, including, at a minimum, the following documentation: \n1. SF1449 a. Complete 30a, b and c; Signature, Print Name & Title of Signer, Date Signed \n\n2. B.1 \n\n3. B.3; Unit Price, Amount  \n\n4. E.3\n\n6. E.10 \n\n7. E.12 \n\n8. E.13 \n\n10. SF30 Amendments (If Amendments are issued) a. Complete15a, b and c; Signature, Print Name & Title of Signer, Date Signed \n\n11. Other documents required in accordance with guidance provided in Additional Submissions section below. \n*Electronic Signatures and Dates are acceptable. (or acknowledge via email) \n2. Quote Submission: The contractors shall email electronic portable document format(.pdf) or Microsoft Excel (.xls) format. The quote shall be valid for 60 days. The quote must include allÂ line itemsÂ contained in theÂ solicitation OR will not be accepted for evaluation.\n3. ***Additional Submissions: Offeror must be an authorized dealer, authorized distributor or authorized reseller for the proposed supplies at the time quotes are due. Offeror must submit, WITH ITS QUOTE, an authorization letter or other documents from the OEM demonstrating its  authorized  status that is dated no more than 90 days prior to the date established in this solicitation as the  Submission of Offers  deadline. *F.O. B is Destination, shipping cost must be included in item prices. \n4. Submissions can be sent in multiple emails to avoid computer system email size limitation. Quotes submitted by any other method will not be considered. All proprietary information should be clearly marked. The use of hyperlinks in quotes is prohibited. Late quotes will not be accepted for evaluation unless determined to be in the best interest of the Government. The contractor is responsible for confirming the Government s receipt of the contractor s quote.","origin":"detail"},"contacts":[{"name":"Choo, Sam","role":"primary","email":"Sam.choo@va.gov","phone":"Sam.choo@va.gov","title":"Contract Specialist"}],"place_of_performance":{"zip":"90073","city":{"name":"Los Angeles"},"state":{"name":"CA"},"street":"Department of Veterans Affairs 11301 Wilshire Blvd","country":{"code":"USA","name":"UNITED STATES"},"street2":"11301 Wilshire Blvd Warehouse"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"naics_codes":["333310"],"award":{"awardee":{}},"attachments":[{"resource_id":"99e5f7a3eb414f09ab67e89f79433140","name":"36C26225Q1410_1.docx","kind":"file","mime_type":".docx","size_bytes":27697,"posted_at":"2025-08-25T20:13:56.015Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/99e5f7a3eb414f09ab67e89f79433140/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C26225P2236_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C26225P2236_3600_-NONE-_-NONE-/","piid":"36C26225P2236","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"M1WNFFFKYSX6","recipient_name":"AANTILIA LLC","recipient_uei":"M1WNFFFKYSX6","recipient_cage":"8EQ30","recipient_city":"AUSTIN","recipient_state":"TX","sub_name":"Department of Veterans Affairs","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","office_key":"o-36C262","first_action_date":"2025-09-22","last_action_date":"2025-09-22","actions":1,"obligated":"176220.86","current_total_value":"176220.86","potential_total_value":"176220.86","naics":"333310","psc":"7910","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":17,"description":"FLOORING EQUIPMENT FOR VAGLA","method":"solicitation","confidence":"high","evidence":["solicitation number 36C26225Q1410 equals the FPDS solicitation identifier","same awarding office 36C262"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C26227Q0085","latest_notice_id":"cdde3a94bda84b199f9d3db72af657a6","title":"S215--SDVOSB Furniture Installation Labor Storage - Base Plus Four Option Years | POP: (12/31/2026 - 12/30/2031) |","solicitation_number":"36C26227Q0085","notice_type":"o","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-23","notices":4,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"493190","psc":"S215","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C26227Q0079","latest_notice_id":"00646e7746494ab38ce53bbe9f7e0f59","title":"W065--RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT","solicitation_number":"36C26227Q0079","notice_type":"k","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-26T20:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"532490","psc":"W065","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0139","latest_notice_id":"156fef93406e495486eb1d4e805bb675","title":"6515--PYXIS IV PREP","solicitation_number":"36C26227Q0139","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541519","psc":"6515","set_aside":"SDVOSBC","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26227Q0146","latest_notice_id":"e2fc7d7b106d4b448a5b57cba568ddb4","title":"J041--KITCHEN HOOD PMIR - Base +4 ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0146","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"561790","psc":"J041","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T08:15:06.508374Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open":[{"key":"N0040627Q0037","latest_notice_id":"9e37c8bf03434e269dd0f05f4e4a4af1","title":"Brand Name Southbend Kettle, Electric, Stationary","solicitation_number":"N0040627Q0037","notice_type":"o","first_type":"o","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00406","office_name":"NAVSUP FLT LOG CTR PUGET SOUND","naics":"333310","psc":"7310","set_aside":"WOSB","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"REQ369230","latest_notice_id":"229f30abcc164940aae9b631b004159c","title":"Iris aiOne System","solicitation_number":"Req-369230","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-01T01:00:00Z","due_date":"2026-11-30","closes_at":"2026-12-01T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899040","office_name":"SLAC Natl Accel Lab -DOE Contractor","naics":"333310","psc":"AJ12","set_aside":null,"state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"W911S227U0181","latest_notice_id":"8e74fb773b7b41c5aaa21254f2e36ffe","title":"Industrial Pressing Equipment","solicitation_number":"W911S227U0181","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T04:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T04:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"333310","psc":"3510","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":"sam_street","state_evidence":"687 ROGERS PLACE WEST POINT, NY 10996","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":59,"indexable":false}