{"canonical":"https://sealedbidder.com/opportunities/36c26225q1105","key":"36C26225Q1105","url":"https://sealedbidder.com/opportunities/36c26225q1105","title":"J030--Annual Generators Preventative Maintenance for VA Long Beach","solicitation_number":"36C26225Q1105","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-07-15T21:00:00Z","first_posted":"2025-07-02","last_posted":"2025-07-02","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"811310","psc":"J030","set_aside":null,"place_state":"CA","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"06037","place_county_name":"Los Angeles County","place_city":"0643000","place_city_name":"Long Beach","winner":null,"award_amount":null,"publications":[{"notice_id":"020d9f3ede314b45b6316590cacf9066","title":"6115--Emergency Generator Long Beach","solicitation_number":"36C26225Q1105","notice_type":"r","base_type":"r","posted":"2025-07-02","posted_at":"2025-07-02T13:52:33.661Z","due_at":"2025-07-15T21:00:00Z","due_date":"2025-07-15","cancelled":false,"archived":true,"archive_date":"2025-10-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/020d9f3ede314b45b6316590cacf9066/view","enriched":true,"history":[{"index":3,"title":"J030--Annual Generators Preventative Maintenance for VA Long Beach","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-02T15:36:43.983Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7a3f7b0d678b4059bab1c4889c0b1827","solicitation_number":"36C26225Q1105","parent_opportunity_id":"020d9f3ede314b45b6316590cacf9066"},{"index":1,"title":"6115--Emergency Generator Long Beach","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-02T13:52:33.661Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"020d9f3ede314b45b6316590cacf9066","solicitation_number":"36C26225Q1105"}]},{"notice_id":"7a3f7b0d678b4059bab1c4889c0b1827","title":"J030--Annual Generators Preventative Maintenance for VA Long Beach","solicitation_number":"36C26225Q1105","notice_type":"r","base_type":"r","posted":"2025-07-02","posted_at":"2025-07-02T15:36:43.983Z","due_at":"2025-07-15T21:00:00Z","due_date":"2025-07-15","cancelled":false,"archived":true,"archive_date":"2025-08-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7a3f7b0d678b4059bab1c4889c0b1827/view","enriched":true,"history":[{"index":3,"title":"J030--Annual Generators Preventative Maintenance for VA Long Beach","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-02T15:36:43.983Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7a3f7b0d678b4059bab1c4889c0b1827","solicitation_number":"36C26225Q1105","parent_opportunity_id":"020d9f3ede314b45b6316590cacf9066"},{"index":1,"title":"6115--Emergency Generator Long Beach","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-02T13:52:33.661Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"020d9f3ede314b45b6316590cacf9066","solicitation_number":"36C26225Q1105"}]}],"latest_notice_id":"7a3f7b0d678b4059bab1c4889c0b1827","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-07-02","posted_at":"2025-07-02T13:52:33.661Z","created_at":"2025-07-02T13:52:31.507Z","modified_at":"2025-08-15T04:02:19.987Z","response_deadline":{"raw":"2025-07-15T15:00:00-06:00","utc":"2025-07-15T21:00:00Z","date":"2025-07-15","time":"15:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/020d9f3ede314b45b6316590cacf9066/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"6115--Emergency Generator Long Beach","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-10-13","archive_type":"auto_custom"},"history":[{"index":3,"title":"J030--Annual Generators Preventative Maintenance for VA Long Beach","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-02T15:36:43.983Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7a3f7b0d678b4059bab1c4889c0b1827","solicitation_number":"36C26225Q1105","parent_opportunity_id":"020d9f3ede314b45b6316590cacf9066"},{"index":1,"title":"6115--Emergency Generator Long Beach","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-02T13:52:33.661Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"020d9f3ede314b45b6316590cacf9066","solicitation_number":"36C26225Q1105"}],"contacts":[{"name":"Mark Welshans","role":"primary","email":"Mark.Welshans@va.gov","phone":"520-792-1450 x16066","title":"Contracting Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"020d9f3ede314b45b6316590cacf9066","lineage_id":"020d9f3ede314b45b6316590cacf9066","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T04:03:44.168611206Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"b445d70e2465f0775deb8ac12e56580df454a84ea85ddbec096651477ae57b6f","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-11T04:03:44.168611206Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS REQUEST FOR INFORMATION (RFI) /SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought Notice / RFI only.  The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 561613 (size standard of $22 Million Dollars). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.  \nThe Department of Veterans Affairs (VA) Long Beach Healthcare System is seeking sources capable of providing Annual Generator Preventative Maintenance for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System.\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. Please see the attached Statement of Work.\nIf your company is interested in and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SALIENT CHARACTERISTICS requirements.  For instances where your company cannot meet the SALIENT CHARACTERISTICS requirement(s), please explain.  For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.  \n(2) Please review the list of SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT CHARACTERISTICS?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components?  Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution?  What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance?  Please specify what FDA clearance(s) have been obtained.\n(15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(18) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Mark.Welshans@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Monday, July 14, 2025 by 15:00 PM PT Local Time.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only.  Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","text":"THIS REQUEST FOR INFORMATION (RFI) /SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 561613 (size standard of $22 Million Dollars). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA) Long Beach Healthcare System is seeking sources capable of providing Annual Generator Preventative Maintenance for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System.\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. Please see the attached Statement of Work.\nIf your company is interested in and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SALIENT CHARACTERISTICS requirements. For instances where your company cannot meet the SALIENT CHARACTERISTICS requirement(s), please explain. For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.\n(2) Please review the list of SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions. If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT CHARACTERISTICS?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution? What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.\n(15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(18) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Mark.Welshans@va.gov. Telephone responses will not be accepted. Responses must be received no later than Monday, July 14, 2025 by 15:00 PM PT Local Time.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26225Q1105","place_of_performance":{"zip":"85723","city":{"name":"Tucson"},"state":{"name":"AZ"},"street":"Department of Veterans Affairs","street2":"NCO 22 - Network Contracting 3601 S. 6th Avenue"},"product_service_code":"6115"},{"award":{"awardee":{}},"dates":{"posted":"2025-07-02","posted_at":"2025-07-02T15:36:43.983Z","created_at":"2025-07-02T15:36:41.737Z","modified_at":"2025-08-15T04:02:19.987Z","response_deadline":{"raw":"2025-07-15T15:00:00-06:00","utc":"2025-07-15T21:00:00Z","date":"2025-07-15","time":"15:00:00","timezone":"America/Denver","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7a3f7b0d678b4059bab1c4889c0b1827/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J030--Annual Generators Preventative Maintenance for VA Long Beach","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-14","archive_type":"auto_custom"},"history":[{"index":3,"title":"J030--Annual Generators Preventative Maintenance for VA Long Beach","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-02T15:36:43.983Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"7a3f7b0d678b4059bab1c4889c0b1827","solicitation_number":"36C26225Q1105","parent_opportunity_id":"020d9f3ede314b45b6316590cacf9066"},{"index":1,"title":"6115--Emergency Generator Long Beach","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-02T13:52:33.661Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"020d9f3ede314b45b6316590cacf9066","solicitation_number":"36C26225Q1105"}],"contacts":[{"name":"Mark Welshans","role":"primary","email":"Mark.Welshans@va.gov","phone":"520-792-1450 x16066","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"7a3f7b0d678b4059bab1c4889c0b1827","lineage_id":"020d9f3ede314b45b6316590cacf9066","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T04:28:58.141703486Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"a1be3e203587992c4b9ae49d2ebb38591d423b7efcc76b1eca637d04dc45b0a8","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-11T04:28:58.141703486Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"This Modification is to update multiple items to the Sources sought.\n1). Change PCS Code from 6115 to J030.\n2). Change the NACIS code from 56163 to 811310.\n3). Change the close date from 07/14/2025 to 07/15/2025 at 3pm Mountain Time.\n\nTHIS REQUEST FOR INFORMATION (RFI) /SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought Notice / RFI only.  The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 811310 (size standard of $12.5 Million Dollars). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.  \nThe Department of Veterans Affairs (VA) Long Beach Healthcare System is seeking sources capable of providing Annual Generator Preventative Maintenance for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System.\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. Please see the attached Statement of Work.\nIf your company is interested in and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SALIENT CHARACTERISTICS requirements.  For instances where your company cannot meet the SALIENT CHARACTERISTICS requirement(s), please explain.  For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.  \n(2) Please review the list of SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT CHARACTERISTICS?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components?  Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution?  What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance?  Please specify what FDA clearance(s) have been obtained.\n(15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(18) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Mark.Welshans@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Tuesday, July 15, 2025 by 15:00 PM  Local Time.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only.  Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement. \n\n\nVHA Long Beach Healthcare System                                                                         Engineering Service\nScope of Work \n\nIFCAP Tracking Number (2237):\n600-25-2-5665-0018\n\nContracting Officer s Representative (COR):  \nName        .\nSalvador Arceo\nService       ...\nEngineering Service\nAddress       ..\nVHA Long Beach Healthcare System                                                                         \n5901 East 7th Street, Long Beach, CA, 90822\nContact Information      .\nOffice: 562-826-8000, ext. 2985\nCellular: 562-721-8023\nEmail: Salvador.arceo@va.gov\n\nContract Title:  \nAnnual Generator Preventative Maintenance \n\nIntroduction & Background:    \nVA Long Beach Healthcare System (VALBHCS) located at 5901 East 7th Street, Long\nBeach, CA 90822-5201, has a requirement for annual generator systems preventative\nmaintenance services for twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System. Generators must be kept in optimal working condition to ensure correct and efficient operation as/when needed at/for the VA Long Beach Healthcare System. Services shall also comply with all VA, local, state, and Federal policies and regulations.\n\nGeneral Requirements:  \nAll work shall be completed at and provided throughout the VHA Long Beach Healthcare System located at 5901 East 7th Street, Long Beach, CA, 90822.\nContractor shall provide all Labor, Parts, Materials, Equipment, and Supervision\nrequired to perform all work.\nContractor (general or sub-contractor) is required to have completed and provide current safety training certifications:\nSuperintendent: 30-hours Construction Safety course.\nTradesmen: Occupational Safety and Health Administration (OSHA) 10-hour Construction Safety training\nContractor shall check-in with the Contracting Officer s Representative (COR) upon arrival at the VHA Long Beach Healthcare System. \nContractor shall wear all OSHA regulated and VHA Personal Protective Equipment (PPE). \nPrior to start of work, contractor personnel shall attend a safety briefing presenting by VA Long Beach safety Department.\nPrior to start of work, ALL energy sources (electrical, water, etc,) must be locked and tagged out, and upon completion of work, will be re-energized and verified.\nDuring the construction process the contractor must ensure safety and exclude the possibility of injury to patient, staff and visitors.  \nContractor will abide by all hospital policies for Infection Control Risk Assessment (ICRA) and Interim Life Safety Measures (ILSM) policies. Contractor will set up work area providing all barriers and protection needed to ensure safe removal and replacement of equipment and/or materials. \nHealthcare System Policy: Infection Prevention & Control Guidelines, Section One-22, Issue Date January 31, 2019, Construction, Renovation, Repair and Demolition \nHealthcare System Policy: Interim Life Safety Measure, Issue Date January 2020.\nDepending on the scope of work, to be defined in the Task Order, the Contract Officer s Representative and Contractor must attain and provide the correct type of permit required by VHA Safety Office. Work cannot commence until the appropriate work permit has been signed off by all parties. The following permits will apply depending on the scope of work:\nHot Work Permit\nAbove the Ceiling and Penetration Permit \nEnergized Electrical Permit\nUtility and Fire Alarm System Permit\nUtility Shutdown Permit \nCollect, contain and dispose of all debris daily and upon completion of work resulting from the overall scope of the project according to VHA Regulations.\nThe contractor is responsible for repairing damages incurred during performance of this scope of work to include removal/installation or moving materials and tools in and out of the work area.\nContractor shall provide the COR with a Master schedule with proposed days to start the PMs withing 7 days of awarded contract. \nContractor shall check-in with, notify, and coordinate ALL work activities through/with the VA Contracting Officer Representative (COR) or designee   prior to scheduling and/or performing any work.\nThe contractor shall provide the COR with a copy of the service report of the service provided for each generator after every service is completed. This will include the name, serial number, model, date and services provided.\n\nScope of Work\n\nThe purpose of this contract is to have a Contractor furnish all equipment, expertise, incidentals, labor, materials, parts, supervision, supplies, tools, and qualified personnel to perform the annual generator systems preventative maintenance services for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System. Services performed shall conform to industry standards and this statement of work (SOW), and lockout-tagout procedures are to be done in accordance with OSHA Standard 29 CFR 1910.147 and VALBHCS policies and regulations.\nThe Contractor is responsible to provide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance of each generator stations as required.\n\nAnnual Service Required but not limited to: (Please See specific task for additional requirements)\n\nCheck fuel and oil levels. Check for leaks. \nInspect air cleaner elements. Clean as required. Inspect crankcase breathers and note any excessive blow-by.\nInspect turbocharger rotation and end play.\nInspect hose s for security, brittleness, cracking, leaks, and weaknesses. Check all hose clamps and tighten as required.\nInspect fans and alternator belts for proper tension and condition. Adjust as required. (Base year belts are replaced)   \nInspect day tank, piping, motors, and levels. Check for leaks. Service fuel/water separators and replace fuel filters.\nInspect batteries, cables and lugs for tightness. Replace batteries annually and fill cells as required. Record battery cells specific gravities. Check for correct electrolyte level. Record DC voltage power supply. Inspect battery charger and record DC voltage power supply.\nInspect engine control panel for loose connections. Tighten as required.\nInspect the jacket water heater for the correct operation.\nInspect water pumps for leaks and/or unusual noises.\nInspect governor and engine controls. Inspect controls and linkage for proper operation. Add lube oil as necessary.\nTest all engine safety shutdown pre-alarms and alarms.\nInspect radiator for leaks and clogged ends. Check cooling systems for anti-freeze and Nalcool protection. Add water and anti-freeze as required for safe engine operation.\nStart engine and warm up. Record operation. Adjust RPM as required. Check for fluid leaks. Check all instruments for proper\noperation.\nChange oil and oil filters.\nTake oil sample for analysis.\nChange fuel filters on the generator.\nInspect junction boxes for loose connections. Tighten as required.\nInspect generator brushes for proper setting and clean slip rings. Lubricate generator bearings.\nInspect and clean generator exciter and regulator. Check for loose connections \nChange air filters\nReplace all batteries\n\n\nSPECIFIC TASKS:\nBATTERIES:\nStarting batteries shall be removed and replaced with new batteries.\nCheck battery chargers for proper algorithm, voltage, and current output.\nFUEL SYSTEM:\nAbove ground diesel tanks and lines shall be inspected for defects.\n\nENGINE:\nCheck for fuel, oil and/or coolant leaks, and tighten all bolts, nuts and retaining devices as necessary.\nGovernor system and linkage shall be checked for binding and proper operation.\nInspect overall condition of air intake and exhaust system.\nAir filters shall be removed and replaced.\nEngine block heater(s) and associated plumbing shall be checked for proper operation.\nBase year all belts shall be changed. Subsequent years, belts shall be checked for proper tension and signs of age, wear, and tear.\nInspect all wiring, cabling, and connections for any corrosion, abrasion, chaffing, or breaks.\nCheck alternator for overall condition and proper current charge output.\nCheck the overall condition of starter.\nCheck and inspect overall condition of equipment for obstructions, debris, and corrosion.\nClean as required.\n\nCOOLING SYSTEM:\nBase year, coolant and radiator caps shall be replaced with new.\nSubsequent years, coolant shall be tested for proper mixture with a coolant test strip.\nRadiator shall be checked externally for debris, leaks, and/or corrosion.\nRadiator cap shall be checked for proper seal.\nAll cooling system hoses shall be checked and tightened.\nCheck coolant system levels and add necessary fluid as required.\n\nGENERATOR CONTROLLER:\nCheck electrical connections and wiring for any corrosion, abrasion, chaffing, and breaks.\nTighten all electrical connections.\nCheck switches and gauges.\nCheck panel lights.\n\nMAINTENANCE SERVICE:\nPerform inspections as noted above.\nChange engine lubricating oil and oil filters.\nChange fuel filters.\nChange water filters and coolant conditioners when used.\nObtain oil samples for analysis by fluid testing Laboratories.\nDispose of maintenance service hazardous waste at an approved disposal site.\nObtain coolant sample for analysist by fluid testing Laboratories and provide report.\nRun generator for thirty (30) minutes after all maintenance is complete to check operation of engine.\nProvide written report of all checked systems, anomalies detected, maintenance accomplished / performed, and recommendations for further maintenance / repairs.\n\nATS Preventative Maintenance Cleaning & Transfer Test\nComplete visual inspection or wiring/connections for tracking, overheating and insulation deterioration.\nVisually inspect for physical damage, anchorage, and grounding.\nVerify NPA is operational (normal power available).\nVisually inspect control wiring.\nVerify EPA light is operational (emergency power available).\nPerform ATS Transfer Test to ensure communication between utility power & ATS. (if allowed by facility)\nIf ATS Test is performed, then verify test light is lit (not present with all ATS)\nCheck and record normal and emergency source voltages\nInspect Solid State Controls for cleanliness and serviceability.\nShut down power and deenergize the ATS (everything that is backed up by the ATS will be down, unless you have an isolation bypass ATS).\nClean, lubricate and inspect transfer mechanism, check alignment, and manually operate in accordance with manufacturers' instructions.\nCheck switch to ensure positive interlock between normal and alternate sources.\nCheck bypass and isolation features, if applicable.\nCheck tightness of all de-energized cable connections and bus and joints.\nAll arc chutes and pole covers are removed and cleaned. Main current carrying contacts inspected for water.\nControl wiring is inspected, and all electrical connections checked for tightness.\nPerform contact resistance tests with switch in both source positions.\nMonitor and verify correct operation and timing for the following:\n\n  Normal voltage sensing relays (if any)\n\n  Engine start sequence\n\n  Time delay upon transfer\n\n  Alternate voltage sensing relay\n\n  Automatic transfer operation\n\n  Interlocks and limit switch function\n\n  Timing delay and retransfer upon normal power restoration\n\nEQUIPMENT TO BE COVERED / SERVICED:\nGENERATOR 5: CUMMINS ONAN 250KW (1 ATS)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll Work can be completed during normal business hours, M-F 8:00AM-4:00PM.\nGENERATOR 5A: CUMMINS ONAN 600KW (2 ATS s- 1 in Bldg 5b)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 5B-1: CATERPILLAR 2.5MW \nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 5B-2: CATERPILLAR 2.5MW \nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 5B-3: CATERPILLAR 2.5MW\nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 126: CUMMINS ONAN 1000KW (6 ATS s- 2 in Bldg 165)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\nGENERATOR 126O/P: CUMMINS ONAN 600KW (4 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\nGENERATOR 133: CUMMINS ONAN 400KW (1 ATS)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 138: CUMMINS ONAN 500KW (3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nB. Provide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nC. All work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\n\nGENERATOR 150: CUMMINS ONAN 360KW (3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 164: DETROIT DIESEL 500KW  ( 3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\nGENERATOR 149: CUMMINS 50KW ( 1 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\n\nContract Modifications:\nModifications for this project must be submitted to the assigned COR who will then submit a formal request to the Contracting Officer (CO). New work is not allowed to commence prior to Contracting Officer s signed and written approval via fully executed Standard Form (SF) 30 modification.\nThe Modification is considered official only when the Contracting Officer and Contractor sign the Modification and the CO provides all parties a copy of the contract Modification. \n\nScheduled Status Reports:\nStatus the schedule and provide a Schedule Status Report on the day the job begins. If, in the opinion of the Contracting Officer, the Contractor falls behind the approved schedule, the Contractor shall take steps necessary to improve its progress including those that may be required by the Contracting Officer, without additional cost to the Government.  \nProgress Meetings:\nThe Government and the Contractor shall meet daily (or as otherwise mutually agreed to) between the meetings described in paragraph Periodic Schedule Update Meetings for the purpose of jointly reviewing the actual progress of the project as compared to the as planned progress and to review planned activities for the upcoming two weeks. The then current and approved schedule update shall be used for the purposes of this meeting and for the production and review of reports. The Contractor's Project Manager and the Authorized Representative of the Contracting Officer shall attend. The weekly progress meeting will address the status of RFI's, RFP's and Submittals.\nThe contractor is responsible for recording Meeting Minutes for all official meetings with the Government and distributing them via email to the meeting participants, COR, and CO, within two (2) working days of the meeting. \nOfficial meetings include, but are not limited to security service coordination meetings, and any meeting the Contractor has with the Contracting Officer or COR regarding the Contract Quality or Performance.\n\nPayment and Invoicing:\nEach invoice will be processed for payment upon the completion of the project and all deliverables within the scope of work have been deemed accomplished by the COR. \nInvoices shall be billed over the course of the project lifespan. shall not be released until the COR deems the project is complete.  \nProgressive invoice payments as directed by the COR and agreed upon by the Contractor.  \n\nPerformance Monitoring - Routine inspections by Facilities Personnel:\nThe Government and the Contractor shall meet weekly (or as otherwise mutually agreed to) between the meetings described in paragraph Periodic Schedule Update for the purpose of jointly reviewing the actual progress of the project as compared to the as planned progress and to review planned activities for the upcoming two weeks. Then the current and approved schedule update shall be used for the purposes of this meeting and for the production and review of reports. The Contractor's Project Manager and the Authorized Representative of the Contracting Officer shall attend. The weekly progress meeting will address the status of RFI's, RFP's and Submittals.\nContractor Qualifications & Certification:\nTechnicians must be certified per NFPA 99 and Joint Commission as determined by the COR. \n\nIdentification, Parking Smoking and VHA Regulations \nContractor shall obtain a  Contractor I.D. Badge  from the VA Police. All Contractor personnel shall ALWAYS wear required visible identification issued by the VA Police during the entire time they are on the VA Healthcare System campus.\nThe COR is responsible for determining the type of Temporary ID badge that will be issued to the Contractor (including Sub-Contractors). All ID badges will be issued via the VHA Police. \nContractors (including Sub-Contractors) are required to wear Temporary ID Badges that are determined by the COR: \nOne to fourteen (1-14) day temporary \nFifteen (15) consecutive days or greater.  A background check is required. In accordance with VHA Directive 0710 all Contractor personnel providing services under this contract shall be the subject to a background screening and must receive favorable adjudication from the VA prior to contract performance. The level of screening for this contract is: Special Agency Check. Any employee whose background investigation yields unfavorable results shall be removed immediately from performance under this contract. In the event the screening is not completed prior to contract performance, the Contractor shall be responsible for the actions of those individuals performing under the contract.\nParking information is available from the VA Police & Security Service Office. It is the responsibility of the Contractor to park only in appropriately designated parking areas. The VA shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\nSmoking is prohibited throughout the VA Healthcare System campus.\nPossession of weapons is prohibited while on the ANY VA Healthcare System campus. Enclosed containers, including tool kits, shall be subject to search / seizure.\nViolations of VA regulations may result in citation answerable in the United States Federal District Court, not at/in the local district, municipal, or state court.\n\nPersonnel Security Requirements:\nThe Office of Security and Law Enforcement provides Department-wide policy on the assignment of appropriate position sensitivity designations associated with Department of Veterans Affairs (VA) positions involving national security and public trust responsibilities, and on the level of background investigations required for applicants for, and incumbents of, those positions.\nThe cost for such investigations shall be borne by the Contractor, either in advance or as reimbursement to the Government. The Contractor shall be required to furnish all applicable employee information required to conduct the investigation, such as, but not limited to, the name, address, and social security number of the Contractor s personnel. The VA will provide all the necessary instructions and guidance for submission of the documents required to conduct the background investigation. Background investigations shall not be required for contract personnel assigned to Low Risk/Non-sensitive positions for 180 days or less under a single contract or series of contracts. However, a Security Access Clearance (SAC) background screening will be required for appropriate preliminary checks IAW VA Directive 0710.\n\nConformance Standards \nAll design and construction accomplished pursuant to this contract shall comply with the latest edition of the following documents unless the contractor is directed otherwise by the Contracting Officer. Any exceptions must be approved in writing by the Contracting Officer prior to construction startup.\nVA Master Construction Specifications\nhttps://www.cfm.va.gov/til/spec.asp#01\nVA Construction Standards\nVA Seismic Design Handbook\nVA Space Planning Criteria\nVA Design Manuals\nVA CADD Standards\nNFPA 101, Life Safety Code\nNFPA 110, Standard for Emergency Standby Power Systems\nNFPA 70, National Electric Code\nNFPA 99, Health Care Facilities\nNFPA 12, Installation of Sprinkler Systems\nAccessibility Standards (ADAAG, ABAAS, Barrier Free Design Guide)\nAIA Guidelines for Construction and Equipment of Hospital and Medical Facilities\nInternational Building Codes\nState and Local codes and guidelines (as applicable)\n\nInsurance Coverage: \nContractor agrees to procure and maintain, while the contract is in effect, Workers Compensation and Employee s Public Liability Insurance in accordance with Federal and State of California laws. The Contractor shall be responsible for all damage to property, which may be done by him, or any employee engaged in the performance of this contract.\nThe Government shall be held harmless against any or all loss, cost, damage, claim expense or liability whatsoever, because of accident or injury to persons or property of others occurring in the performance of this contract.\nBefore commencing work under this contract, the Contracting Officer shall require the Contractor to furnish certification from his/her insurance company indicating that the coverage specified by FAR 52.228-5 and per FAR Subpart 28.307-2 has been obtained and that it may not be changed or canceled without guaranteed thirty (30) day notice to the Contracting Officer.\nContractor is required to provide copies of proof of Workers Compensation and Employee Public Liability Insurance within fifteen (15) calendar days after notification of contract award.\n\nGovernment-Furnished Equipment / Government-Furnished Information:  \nNo government equipment will be used by the awarded Contractors.\n\nRisk Control:\nIf applicable, the Contracting Officer s Representative will work with VHA Safety and Infection Control services to establish an Interim Life Safety Measures (ILSM) and Infection Control Risk Assessment (ICRA) that must be followed by the Contractor. \nVHA requires documentation of Tuberculosis (TB) risk assessment for contractors, and dependent on the project risk level, documentation of results of TB testing and follow-up of those with positive results. VHA Directive 2011-036.\n\nPlace of Performance:\nVHA Long Beach Healthcare System located at 5901 East 7th Street, Long Beach, CA, 90822.  \nAll work shall be scheduled during normal work hours (7:00 AM to 4:30 PM) Monday   Friday, Pacific Standard Time (PST), excluding Federal Holidays. Work shall not impact patient care services.  \nWeekend (Saturday or Sunday) work must be approved by the COR assigned to the Task Order.\nAfter hours (6PM-6AM, Pacific Standard Time (PST)) work must be approved by the COR.\nAny overtime or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government. \nIf a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\nGovernment Holidays observed include:\nNew Year s Day        .. ..\nJanuary 1st\nMartin Luther King s Birthday ..  ....                          \nThird Monday in January\nPresidents Day     ..    . \nThird Monday in February\nMemorial Day         . ..\nLast Monday in May\nIndependence Day         \nJuly 4th\nLabor Day        .. ..  .\nFirst Monday in September\nColumbus Day          ..\nSecond Monday in October\nVeterans Day           .\nNovember llth\nThanksgiving Day         ..\nFourth Thursday in November\nChristmas Day            \n25 December\n\nPeriod of Performance:\n365 days post the Notice to Proceed (NTP) being issued to the Contractor. \n\nDelivery Schedule:\n       Contact the Contracting Officer s Representative (COR).","text":"This Modification is to update multiple items to the Sources sought.\n1). Change PCS Code from 6115 to J030.\n2). Change the NACIS code from 56163 to 811310.\n3). Change the close date from 07/14/2025 to 07/15/2025 at 3pm Mountain Time.\n\nTHIS REQUEST FOR INFORMATION (RFI) /SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 811310 (size standard of $12.5 Million Dollars). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA) Long Beach Healthcare System is seeking sources capable of providing Annual Generator Preventative Maintenance for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System.\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. Please see the attached Statement of Work.\nIf your company is interested in and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SALIENT CHARACTERISTICS requirements. For instances where your company cannot meet the SALIENT CHARACTERISTICS requirement(s), please explain. For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.\n(2) Please review the list of SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions. If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT CHARACTERISTICS?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution? What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.\n(15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(18) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Mark.Welshans@va.gov. Telephone responses will not be accepted. Responses must be received no later than Tuesday, July 15, 2025 by 15:00 PM Local Time.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.\n\nVHA Long Beach Healthcare System Engineering Service\nScope of Work\n\nIFCAP Tracking Number (2237):\n600-25-2-5665-0018\n\nContracting Officer s Representative (COR):\nName .\nSalvador Arceo\nService ...\nEngineering Service\nAddress ..\nVHA Long Beach Healthcare System\n5901 East 7th Street, Long Beach, CA, 90822\nContact Information .\nOffice: 562-826-8000, ext. 2985\nCellular: 562-721-8023\nEmail: Salvador.arceo@va.gov\n\nContract Title:\nAnnual Generator Preventative Maintenance\n\nIntroduction & Background:\nVA Long Beach Healthcare System (VALBHCS) located at 5901 East 7th Street, Long\nBeach, CA 90822-5201, has a requirement for annual generator systems preventative\nmaintenance services for twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System. Generators must be kept in optimal working condition to ensure correct and efficient operation as/when needed at/for the VA Long Beach Healthcare System. Services shall also comply with all VA, local, state, and Federal policies and regulations.\n\nGeneral Requirements:\nAll work shall be completed at and provided throughout the VHA Long Beach Healthcare System located at 5901 East 7th Street, Long Beach, CA, 90822.\nContractor shall provide all Labor, Parts, Materials, Equipment, and Supervision\nrequired to perform all work.\nContractor (general or sub-contractor) is required to have completed and provide current safety training certifications:\nSuperintendent: 30-hours Construction Safety course.\nTradesmen: Occupational Safety and Health Administration (OSHA) 10-hour Construction Safety training\nContractor shall check-in with the Contracting Officer s Representative (COR) upon arrival at the VHA Long Beach Healthcare System.\nContractor shall wear all OSHA regulated and VHA Personal Protective Equipment (PPE).\nPrior to start of work, contractor personnel shall attend a safety briefing presenting by VA Long Beach safety Department.\nPrior to start of work, ALL energy sources (electrical, water, etc,) must be locked and tagged out, and upon completion of work, will be re-energized and verified.\nDuring the construction process the contractor must ensure safety and exclude the possibility of injury to patient, staff and visitors.\nContractor will abide by all hospital policies for Infection Control Risk Assessment (ICRA) and Interim Life Safety Measures (ILSM) policies. Contractor will set up work area providing all barriers and protection needed to ensure safe removal and replacement of equipment and/or materials.\nHealthcare System Policy: Infection Prevention & Control Guidelines, Section One-22, Issue Date January 31, 2019, Construction, Renovation, Repair and Demolition\nHealthcare System Policy: Interim Life Safety Measure, Issue Date January 2020.\nDepending on the scope of work, to be defined in the Task Order, the Contract Officer s Representative and Contractor must attain and provide the correct type of permit required by VHA Safety Office. Work cannot commence until the appropriate work permit has been signed off by all parties. The following permits will apply depending on the scope of work:\nHot Work Permit\nAbove the Ceiling and Penetration Permit\nEnergized Electrical Permit\nUtility and Fire Alarm System Permit\nUtility Shutdown Permit\nCollect, contain and dispose of all debris daily and upon completion of work resulting from the overall scope of the project according to VHA Regulations.\nThe contractor is responsible for repairing damages incurred during performance of this scope of work to include removal/installation or moving materials and tools in and out of the work area.\nContractor shall provide the COR with a Master schedule with proposed days to start the PMs withing 7 days of awarded contract.\nContractor shall check-in with, notify, and coordinate ALL work activities through/with the VA Contracting Officer Representative (COR) or designee prior to scheduling and/or performing any work.\nThe contractor shall provide the COR with a copy of the service report of the service provided for each generator after every service is completed. This will include the name, serial number, model, date and services provided.\n\nScope of Work\n\nThe purpose of this contract is to have a Contractor furnish all equipment, expertise, incidentals, labor, materials, parts, supervision, supplies, tools, and qualified personnel to perform the annual generator systems preventative maintenance services for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System. Services performed shall conform to industry standards and this statement of work (SOW), and lockout-tagout procedures are to be done in accordance with OSHA Standard 29 CFR 1910.147 and VALBHCS policies and regulations.\nThe Contractor is responsible to provide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance of each generator stations as required.\n\nAnnual Service Required but not limited to: (Please See specific task for additional requirements)\n\nCheck fuel and oil levels. Check for leaks.\nInspect air cleaner elements. Clean as required. Inspect crankcase breathers and note any excessive blow-by.\nInspect turbocharger rotation and end play.\nInspect hose s for security, brittleness, cracking, leaks, and weaknesses. Check all hose clamps and tighten as required.\nInspect fans and alternator belts for proper tension and condition. Adjust as required. (Base year belts are replaced)\nInspect day tank, piping, motors, and levels. Check for leaks. Service fuel/water separators and replace fuel filters.\nInspect batteries, cables and lugs for tightness. Replace batteries annually and fill cells as required. Record battery cells specific gravities. Check for correct electrolyte level. Record DC voltage power supply. Inspect battery charger and record DC voltage power supply.\nInspect engine control panel for loose connections. Tighten as required.\nInspect the jacket water heater for the correct operation.\nInspect water pumps for leaks and/or unusual noises.\nInspect governor and engine controls. Inspect controls and linkage for proper operation. Add lube oil as necessary.\nTest all engine safety shutdown pre-alarms and alarms.\nInspect radiator for leaks and clogged ends. Check cooling systems for anti-freeze and Nalcool protection. Add water and anti-freeze as required for safe engine operation.\nStart engine and warm up. Record operation. Adjust RPM as required. Check for fluid leaks. Check all instruments for proper\noperation.\nChange oil and oil filters.\nTake oil sample for analysis.\nChange fuel filters on the generator.\nInspect junction boxes for loose connections. Tighten as required.\nInspect generator brushes for proper setting and clean slip rings. Lubricate generator bearings.\nInspect and clean generator exciter and regulator. Check for loose connections\nChange air filters\nReplace all batteries\n\nSPECIFIC TASKS:\nBATTERIES:\nStarting batteries shall be removed and replaced with new batteries.\nCheck battery chargers for proper algorithm, voltage, and current output.\nFUEL SYSTEM:\nAbove ground diesel tanks and lines shall be inspected for defects.\n\nENGINE:\nCheck for fuel, oil and/or coolant leaks, and tighten all bolts, nuts and retaining devices as necessary.\nGovernor system and linkage shall be checked for binding and proper operation.\nInspect overall condition of air intake and exhaust system.\nAir filters shall be removed and replaced.\nEngine block heater(s) and associated plumbing shall be checked for proper operation.\nBase year all belts shall be changed. Subsequent years, belts shall be checked for proper tension and signs of age, wear, and tear.\nInspect all wiring, cabling, and connections for any corrosion, abrasion, chaffing, or breaks.\nCheck alternator for overall condition and proper current charge output.\nCheck the overall condition of starter.\nCheck and inspect overall condition of equipment for obstructions, debris, and corrosion.\nClean as required.\n\nCOOLING SYSTEM:\nBase year, coolant and radiator caps shall be replaced with new.\nSubsequent years, coolant shall be tested for proper mixture with a coolant test strip.\nRadiator shall be checked externally for debris, leaks, and/or corrosion.\nRadiator cap shall be checked for proper seal.\nAll cooling system hoses shall be checked and tightened.\nCheck coolant system levels and add necessary fluid as required.\n\nGENERATOR CONTROLLER:\nCheck electrical connections and wiring for any corrosion, abrasion, chaffing, and breaks.\nTighten all electrical connections.\nCheck switches and gauges.\nCheck panel lights.\n\nMAINTENANCE SERVICE:\nPerform inspections as noted above.\nChange engine lubricating oil and oil filters.\nChange fuel filters.\nChange water filters and coolant conditioners when used.\nObtain oil samples for analysis by fluid testing Laboratories.\nDispose of maintenance service hazardous waste at an approved disposal site.\nObtain coolant sample for analysist by fluid testing Laboratories and provide report.\nRun generator for thirty (30) minutes after all maintenance is complete to check operation of engine.\nProvide written report of all checked systems, anomalies detected, maintenance accomplished / performed, and recommendations for further maintenance / repairs.\n\nATS Preventative Maintenance Cleaning & Transfer Test\nComplete visual inspection or wiring/connections for tracking, overheating and insulation deterioration.\nVisually inspect for physical damage, anchorage, and grounding.\nVerify NPA is operational (normal power available).\nVisually inspect control wiring.\nVerify EPA light is operational (emergency power available).\nPerform ATS Transfer Test to ensure communication between utility power & ATS. (if allowed by facility)\nIf ATS Test is performed, then verify test light is lit (not present with all ATS)\nCheck and record normal and emergency source voltages\nInspect Solid State Controls for cleanliness and serviceability.\nShut down power and deenergize the ATS (everything that is backed up by the ATS will be down, unless you have an isolation bypass ATS).\nClean, lubricate and inspect transfer mechanism, check alignment, and manually operate in accordance with manufacturers' instructions.\nCheck switch to ensure positive interlock between normal and alternate sources.\nCheck bypass and isolation features, if applicable.\nCheck tightness of all de-energized cable connections and bus and joints.\nAll arc chutes and pole covers are removed and cleaned. Main current carrying contacts inspected for water.\nControl wiring is inspected, and all electrical connections checked for tightness.\nPerform contact resistance tests with switch in both source positions.\nMonitor and verify correct operation and timing for the following:\n\nNormal voltage sensing relays (if any)\n\nEngine start sequence\n\nTime delay upon transfer\n\nAlternate voltage sensing relay\n\nAutomatic transfer operation\n\nInterlocks and limit switch function\n\nTiming delay and retransfer upon normal power restoration\n\nEQUIPMENT TO BE COVERED / SERVICED:\nGENERATOR 5: CUMMINS ONAN 250KW (1 ATS)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll Work can be completed during normal business hours, M-F 8:00AM-4:00PM.\nGENERATOR 5A: CUMMINS ONAN 600KW (2 ATS s- 1 in Bldg 5b)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 5B-1: CATERPILLAR 2.5MW\nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 5B-2: CATERPILLAR 2.5MW\nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 5B-3: CATERPILLAR 2.5MW\nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 126: CUMMINS ONAN 1000KW (6 ATS s- 2 in Bldg 165)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\nGENERATOR 126O/P: CUMMINS ONAN 600KW (4 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\nGENERATOR 133: CUMMINS ONAN 400KW (1 ATS)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 138: CUMMINS ONAN 500KW (3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nB. Provide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nC. All work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\n\nGENERATOR 150: CUMMINS ONAN 360KW (3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 164: DETROIT DIESEL 500KW ( 3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\nGENERATOR 149: CUMMINS 50KW ( 1 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\n\nContract Modifications:\nModifications for this project must be submitted to the assigned COR who will then submit a formal request to the Contracting Officer (CO). New work is not allowed to commence prior to Contracting Officer s signed and written approval via fully executed Standard Form (SF) 30 modification.\nThe Modification is considered official only when the Contracting Officer and Contractor sign the Modification and the CO provides all parties a copy of the contract Modification.\n\nScheduled Status Reports:\nStatus the schedule and provide a Schedule Status Report on the day the job begins. If, in the opinion of the Contracting Officer, the Contractor falls behind the approved schedule, the Contractor shall take steps necessary to improve its progress including those that may be required by the Contracting Officer, without additional cost to the Government.\nProgress Meetings:\nThe Government and the Contractor shall meet daily (or as otherwise mutually agreed to) between the meetings described in paragraph Periodic Schedule Update Meetings for the purpose of jointly reviewing the actual progress of the project as compared to the as planned progress and to review planned activities for the upcoming two weeks. The then current and approved schedule update shall be used for the purposes of this meeting and for the production and review of reports. The Contractor's Project Manager and the Authorized Representative of the Contracting Officer shall attend. The weekly progress meeting will address the status of RFI's, RFP's and Submittals.\nThe contractor is responsible for recording Meeting Minutes for all official meetings with the Government and distributing them via email to the meeting participants, COR, and CO, within two (2) working days of the meeting.\nOfficial meetings include, but are not limited to security service coordination meetings, and any meeting the Contractor has with the Contracting Officer or COR regarding the Contract Quality or Performance.\n\nPayment and Invoicing:\nEach invoice will be processed for payment upon the completion of the project and all deliverables within the scope of work have been deemed accomplished by the COR.\nInvoices shall be billed over the course of the project lifespan. shall not be released until the COR deems the project is complete.\nProgressive invoice payments as directed by the COR and agreed upon by the Contractor.\n\nPerformance Monitoring - Routine inspections by Facilities Personnel:\nThe Government and the Contractor shall meet weekly (or as otherwise mutually agreed to) between the meetings described in paragraph Periodic Schedule Update for the purpose of jointly reviewing the actual progress of the project as compared to the as planned progress and to review planned activities for the upcoming two weeks. Then the current and approved schedule update shall be used for the purposes of this meeting and for the production and review of reports. The Contractor's Project Manager and the Authorized Representative of the Contracting Officer shall attend. The weekly progress meeting will address the status of RFI's, RFP's and Submittals.\nContractor Qualifications & Certification:\nTechnicians must be certified per NFPA 99 and Joint Commission as determined by the COR.\n\nIdentification, Parking Smoking and VHA Regulations\nContractor shall obtain a Contractor I.D. Badge from the VA Police. All Contractor personnel shall ALWAYS wear required visible identification issued by the VA Police during the entire time they are on the VA Healthcare System campus.\nThe COR is responsible for determining the type of Temporary ID badge that will be issued to the Contractor (including Sub-Contractors). All ID badges will be issued via the VHA Police.\nContractors (including Sub-Contractors) are required to wear Temporary ID Badges that are determined by the COR:\nOne to fourteen (1-14) day temporary\nFifteen (15) consecutive days or greater. A background check is required. In accordance with VHA Directive 0710 all Contractor personnel providing services under this contract shall be the subject to a background screening and must receive favorable adjudication from the VA prior to contract performance. The level of screening for this contract is: Special Agency Check. Any employee whose background investigation yields unfavorable results shall be removed immediately from performance under this contract. In the event the screening is not completed prior to contract performance, the Contractor shall be responsible for the actions of those individuals performing under the contract.\nParking information is available from the VA Police & Security Service Office. It is the responsibility of the Contractor to park only in appropriately designated parking areas. The VA shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\nSmoking is prohibited throughout the VA Healthcare System campus.\nPossession of weapons is prohibited while on the ANY VA Healthcare System campus. Enclosed containers, including tool kits, shall be subject to search / seizure.\nViolations of VA regulations may result in citation answerable in the United States Federal District Court, not at/in the local district, municipal, or state court.\n\nPersonnel Security Requirements:\nThe Office of Security and Law Enforcement provides Department-wide policy on the assignment of appropriate position sensitivity designations associated with Department of Veterans Affairs (VA) positions involving national security and public trust responsibilities, and on the level of background investigations required for applicants for, and incumbents of, those positions.\nThe cost for such investigations shall be borne by the Contractor, either in advance or as reimbursement to the Government. The Contractor shall be required to furnish all applicable employee information required to conduct the investigation, such as, but not limited to, the name, address, and social security number of the Contractor s personnel. The VA will provide all the necessary instructions and guidance for submission of the documents required to conduct the background investigation. Background investigations shall not be required for contract personnel assigned to Low Risk/Non-sensitive positions for 180 days or less under a single contract or series of contracts. However, a Security Access Clearance (SAC) background screening will be required for appropriate preliminary checks IAW VA Directive 0710.\n\nConformance Standards\nAll design and construction accomplished pursuant to this contract shall comply with the latest edition of the following documents unless the contractor is directed otherwise by the Contracting Officer. Any exceptions must be approved in writing by the Contracting Officer prior to construction startup.\nVA Master Construction Specifications\nhttps://www.cfm.va.gov/til/spec.asp#01\nVA Construction Standards\nVA Seismic Design Handbook\nVA Space Planning Criteria\nVA Design Manuals\nVA CADD Standards\nNFPA 101, Life Safety Code\nNFPA 110, Standard for Emergency Standby Power Systems\nNFPA 70, National Electric Code\nNFPA 99, Health Care Facilities\nNFPA 12, Installation of Sprinkler Systems\nAccessibility Standards (ADAAG, ABAAS, Barrier Free Design Guide)\nAIA Guidelines for Construction and Equipment of Hospital and Medical Facilities\nInternational Building Codes\nState and Local codes and guidelines (as applicable)\n\nInsurance Coverage:\nContractor agrees to procure and maintain, while the contract is in effect, Workers Compensation and Employee s Public Liability Insurance in accordance with Federal and State of California laws. The Contractor shall be responsible for all damage to property, which may be done by him, or any employee engaged in the performance of this contract.\nThe Government shall be held harmless against any or all loss, cost, damage, claim expense or liability whatsoever, because of accident or injury to persons or property of others occurring in the performance of this contract.\nBefore commencing work under this contract, the Contracting Officer shall require the Contractor to furnish certification from his/her insurance company indicating that the coverage specified by FAR 52.228-5 and per FAR Subpart 28.307-2 has been obtained and that it may not be changed or canceled without guaranteed thirty (30) day notice to the Contracting Officer.\nContractor is required to provide copies of proof of Workers Compensation and Employee Public Liability Insurance within fifteen (15) calendar days after notification of contract award.\n\nGovernment-Furnished Equipment / Government-Furnished Information:\nNo government equipment will be used by the awarded Contractors.\n\nRisk Control:\nIf applicable, the Contracting Officer s Representative will work with VHA Safety and Infection Control services to establish an Interim Life Safety Measures (ILSM) and Infection Control Risk Assessment (ICRA) that must be followed by the Contractor.\nVHA requires documentation of Tuberculosis (TB) risk assessment for contractors, and dependent on the project risk level, documentation of results of TB testing and follow-up of those with positive results. VHA Directive 2011-036.\n\nPlace of Performance:\nVHA Long Beach Healthcare System located at 5901 East 7th Street, Long Beach, CA, 90822.\nAll work shall be scheduled during normal work hours (7:00 AM to 4:30 PM) Monday Friday, Pacific Standard Time (PST), excluding Federal Holidays. Work shall not impact patient care services.\nWeekend (Saturday or Sunday) work must be approved by the COR assigned to the Task Order.\nAfter hours (6PM-6AM, Pacific Standard Time (PST)) work must be approved by the COR.\nAny overtime or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government.\nIf a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\nGovernment Holidays observed include:\nNew Year s Day .. ..\nJanuary 1st\nMartin Luther King s Birthday .. ....\nThird Monday in January\nPresidents Day .. .\nThird Monday in February\nMemorial Day . ..\nLast Monday in May\nIndependence Day\nJuly 4th\nLabor Day .. .. .\nFirst Monday in September\nColumbus Day ..\nSecond Monday in October\nVeterans Day .\nNovember llth\nThanksgiving Day ..\nFourth Thursday in November\nChristmas Day\n25 December\n\nPeriod of Performance:\n365 days post the Notice to Proceed (NTP) being issued to the Contractor.\n\nDelivery Schedule:\nContact the Contracting Officer s Representative (COR).","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26225Q1105","place_of_performance":{"zip":"90822","city":{"name":"Long Beach"},"state":{"name":"CA"},"street":"VHA Long Beach Health Care System","street2":"Department of Veterans Affairs 5901 East 7th Street"},"product_service_code":"J030"}],"due_at":"2025-07-15T21:00:00Z","due_date":"2025-07-15","closes_at":"2025-07-15T21:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":null,"state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-11T04:53:52.348876Z","principal_notice_id":"7a3f7b0d678b4059bab1c4889c0b1827","description":{"text":"This Modification is to update multiple items to the Sources sought.\n1). Change PCS Code from 6115 to J030.\n2). Change the NACIS code from 56163 to 811310.\n3). Change the close date from 07/14/2025 to 07/15/2025 at 3pm Mountain Time.\n\nTHIS REQUEST FOR INFORMATION (RFI) /SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 811310 (size standard of $12.5 Million Dollars). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA) Long Beach Healthcare System is seeking sources capable of providing Annual Generator Preventative Maintenance for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System.\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. Please see the attached Statement of Work.\nIf your company is interested in and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SALIENT CHARACTERISTICS requirements. For instances where your company cannot meet the SALIENT CHARACTERISTICS requirement(s), please explain. For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.\n(2) Please review the list of SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions. If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT CHARACTERISTICS?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution? What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.\n(15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(18) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Mark.Welshans@va.gov. Telephone responses will not be accepted. Responses must be received no later than Tuesday, July 15, 2025 by 15:00 PM Local Time.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.\n\nVHA Long Beach Healthcare System Engineering Service\nScope of Work\n\nIFCAP Tracking Number (2237):\n600-25-2-5665-0018\n\nContracting Officer s Representative (COR):\nName .\nSalvador Arceo\nService ...\nEngineering Service\nAddress ..\nVHA Long Beach Healthcare System\n5901 East 7th Street, Long Beach, CA, 90822\nContact Information .\nOffice: 562-826-8000, ext. 2985\nCellular: 562-721-8023\nEmail: Salvador.arceo@va.gov\n\nContract Title:\nAnnual Generator Preventative Maintenance\n\nIntroduction & Background:\nVA Long Beach Healthcare System (VALBHCS) located at 5901 East 7th Street, Long\nBeach, CA 90822-5201, has a requirement for annual generator systems preventative\nmaintenance services for twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System. Generators must be kept in optimal working condition to ensure correct and efficient operation as/when needed at/for the VA Long Beach Healthcare System. Services shall also comply with all VA, local, state, and Federal policies and regulations.\n\nGeneral Requirements:\nAll work shall be completed at and provided throughout the VHA Long Beach Healthcare System located at 5901 East 7th Street, Long Beach, CA, 90822.\nContractor shall provide all Labor, Parts, Materials, Equipment, and Supervision\nrequired to perform all work.\nContractor (general or sub-contractor) is required to have completed and provide current safety training certifications:\nSuperintendent: 30-hours Construction Safety course.\nTradesmen: Occupational Safety and Health Administration (OSHA) 10-hour Construction Safety training\nContractor shall check-in with the Contracting Officer s Representative (COR) upon arrival at the VHA Long Beach Healthcare System.\nContractor shall wear all OSHA regulated and VHA Personal Protective Equipment (PPE).\nPrior to start of work, contractor personnel shall attend a safety briefing presenting by VA Long Beach safety Department.\nPrior to start of work, ALL energy sources (electrical, water, etc,) must be locked and tagged out, and upon completion of work, will be re-energized and verified.\nDuring the construction process the contractor must ensure safety and exclude the possibility of injury to patient, staff and visitors.\nContractor will abide by all hospital policies for Infection Control Risk Assessment (ICRA) and Interim Life Safety Measures (ILSM) policies. Contractor will set up work area providing all barriers and protection needed to ensure safe removal and replacement of equipment and/or materials.\nHealthcare System Policy: Infection Prevention & Control Guidelines, Section One-22, Issue Date January 31, 2019, Construction, Renovation, Repair and Demolition\nHealthcare System Policy: Interim Life Safety Measure, Issue Date January 2020.\nDepending on the scope of work, to be defined in the Task Order, the Contract Officer s Representative and Contractor must attain and provide the correct type of permit required by VHA Safety Office. Work cannot commence until the appropriate work permit has been signed off by all parties. The following permits will apply depending on the scope of work:\nHot Work Permit\nAbove the Ceiling and Penetration Permit\nEnergized Electrical Permit\nUtility and Fire Alarm System Permit\nUtility Shutdown Permit\nCollect, contain and dispose of all debris daily and upon completion of work resulting from the overall scope of the project according to VHA Regulations.\nThe contractor is responsible for repairing damages incurred during performance of this scope of work to include removal/installation or moving materials and tools in and out of the work area.\nContractor shall provide the COR with a Master schedule with proposed days to start the PMs withing 7 days of awarded contract.\nContractor shall check-in with, notify, and coordinate ALL work activities through/with the VA Contracting Officer Representative (COR) or designee prior to scheduling and/or performing any work.\nThe contractor shall provide the COR with a copy of the service report of the service provided for each generator after every service is completed. This will include the name, serial number, model, date and services provided.\n\nScope of Work\n\nThe purpose of this contract is to have a Contractor furnish all equipment, expertise, incidentals, labor, materials, parts, supervision, supplies, tools, and qualified personnel to perform the annual generator systems preventative maintenance services for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System. Services performed shall conform to industry standards and this statement of work (SOW), and lockout-tagout procedures are to be done in accordance with OSHA Standard 29 CFR 1910.147 and VALBHCS policies and regulations.\nThe Contractor is responsible to provide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance of each generator stations as required.\n\nAnnual Service Required but not limited to: (Please See specific task for additional requirements)\n\nCheck fuel and oil levels. Check for leaks.\nInspect air cleaner elements. Clean as required. Inspect crankcase breathers and note any excessive blow-by.\nInspect turbocharger rotation and end play.\nInspect hose s for security, brittleness, cracking, leaks, and weaknesses. Check all hose clamps and tighten as required.\nInspect fans and alternator belts for proper tension and condition. Adjust as required. (Base year belts are replaced)\nInspect day tank, piping, motors, and levels. Check for leaks. Service fuel/water separators and replace fuel filters.\nInspect batteries, cables and lugs for tightness. Replace batteries annually and fill cells as required. Record battery cells specific gravities. Check for correct electrolyte level. Record DC voltage power supply. Inspect battery charger and record DC voltage power supply.\nInspect engine control panel for loose connections. Tighten as required.\nInspect the jacket water heater for the correct operation.\nInspect water pumps for leaks and/or unusual noises.\nInspect governor and engine controls. Inspect controls and linkage for proper operation. Add lube oil as necessary.\nTest all engine safety shutdown pre-alarms and alarms.\nInspect radiator for leaks and clogged ends. Check cooling systems for anti-freeze and Nalcool protection. Add water and anti-freeze as required for safe engine operation.\nStart engine and warm up. Record operation. Adjust RPM as required. Check for fluid leaks. Check all instruments for proper\noperation.\nChange oil and oil filters.\nTake oil sample for analysis.\nChange fuel filters on the generator.\nInspect junction boxes for loose connections. Tighten as required.\nInspect generator brushes for proper setting and clean slip rings. Lubricate generator bearings.\nInspect and clean generator exciter and regulator. Check for loose connections\nChange air filters\nReplace all batteries\n\nSPECIFIC TASKS:\nBATTERIES:\nStarting batteries shall be removed and replaced with new batteries.\nCheck battery chargers for proper algorithm, voltage, and current output.\nFUEL SYSTEM:\nAbove ground diesel tanks and lines shall be inspected for defects.\n\nENGINE:\nCheck for fuel, oil and/or coolant leaks, and tighten all bolts, nuts and retaining devices as necessary.\nGovernor system and linkage shall be checked for binding and proper operation.\nInspect overall condition of air intake and exhaust system.\nAir filters shall be removed and replaced.\nEngine block heater(s) and associated plumbing shall be checked for proper operation.\nBase year all belts shall be changed. Subsequent years, belts shall be checked for proper tension and signs of age, wear, and tear.\nInspect all wiring, cabling, and connections for any corrosion, abrasion, chaffing, or breaks.\nCheck alternator for overall condition and proper current charge output.\nCheck the overall condition of starter.\nCheck and inspect overall condition of equipment for obstructions, debris, and corrosion.\nClean as required.\n\nCOOLING SYSTEM:\nBase year, coolant and radiator caps shall be replaced with new.\nSubsequent years, coolant shall be tested for proper mixture with a coolant test strip.\nRadiator shall be checked externally for debris, leaks, and/or corrosion.\nRadiator cap shall be checked for proper seal.\nAll cooling system hoses shall be checked and tightened.\nCheck coolant system levels and add necessary fluid as required.\n\nGENERATOR CONTROLLER:\nCheck electrical connections and wiring for any corrosion, abrasion, chaffing, and breaks.\nTighten all electrical connections.\nCheck switches and gauges.\nCheck panel lights.\n\nMAINTENANCE SERVICE:\nPerform inspections as noted above.\nChange engine lubricating oil and oil filters.\nChange fuel filters.\nChange water filters and coolant conditioners when used.\nObtain oil samples for analysis by fluid testing Laboratories.\nDispose of maintenance service hazardous waste at an approved disposal site.\nObtain coolant sample for analysist by fluid testing Laboratories and provide report.\nRun generator for thirty (30) minutes after all maintenance is complete to check operation of engine.\nProvide written report of all checked systems, anomalies detected, maintenance accomplished / performed, and recommendations for further maintenance / repairs.\n\nATS Preventative Maintenance Cleaning & Transfer Test\nComplete visual inspection or wiring/connections for tracking, overheating and insulation deterioration.\nVisually inspect for physical damage, anchorage, and grounding.\nVerify NPA is operational (normal power available).\nVisually inspect control wiring.\nVerify EPA light is operational (emergency power available).\nPerform ATS Transfer Test to ensure communication between utility power & ATS. (if allowed by facility)\nIf ATS Test is performed, then verify test light is lit (not present with all ATS)\nCheck and record normal and emergency source voltages\nInspect Solid State Controls for cleanliness and serviceability.\nShut down power and deenergize the ATS (everything that is backed up by the ATS will be down, unless you have an isolation bypass ATS).\nClean, lubricate and inspect transfer mechanism, check alignment, and manually operate in accordance with manufacturers' instructions.\nCheck switch to ensure positive interlock between normal and alternate sources.\nCheck bypass and isolation features, if applicable.\nCheck tightness of all de-energized cable connections and bus and joints.\nAll arc chutes and pole covers are removed and cleaned. Main current carrying contacts inspected for water.\nControl wiring is inspected, and all electrical connections checked for tightness.\nPerform contact resistance tests with switch in both source positions.\nMonitor and verify correct operation and timing for the following:\n\nNormal voltage sensing relays (if any)\n\nEngine start sequence\n\nTime delay upon transfer\n\nAlternate voltage sensing relay\n\nAutomatic transfer operation\n\nInterlocks and limit switch function\n\nTiming delay and retransfer upon normal power restoration\n\nEQUIPMENT TO BE COVERED / SERVICED:\nGENERATOR 5: CUMMINS ONAN 250KW (1 ATS)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll Work can be completed during normal business hours, M-F 8:00AM-4:00PM.\nGENERATOR 5A: CUMMINS ONAN 600KW (2 ATS s- 1 in Bldg 5b)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 5B-1: CATERPILLAR 2.5MW\nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 5B-2: CATERPILLAR 2.5MW\nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 5B-3: CATERPILLAR 2.5MW\nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 126: CUMMINS ONAN 1000KW (6 ATS s- 2 in Bldg 165)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\nGENERATOR 126O/P: CUMMINS ONAN 600KW (4 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\nGENERATOR 133: CUMMINS ONAN 400KW (1 ATS)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 138: CUMMINS ONAN 500KW (3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nB. Provide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nC. All work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\n\nGENERATOR 150: CUMMINS ONAN 360KW (3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M F 8:00AM 4:00PM.\nGENERATOR 164: DETROIT DIESEL 500KW ( 3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\nGENERATOR 149: CUMMINS 50KW ( 1 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM 4:00PM.\n\nContract Modifications:\nModifications for this project must be submitted to the assigned COR who will then submit a formal request to the Contracting Officer (CO). New work is not allowed to commence prior to Contracting Officer s signed and written approval via fully executed Standard Form (SF) 30 modification.\nThe Modification is considered official only when the Contracting Officer and Contractor sign the Modification and the CO provides all parties a copy of the contract Modification.\n\nScheduled Status Reports:\nStatus the schedule and provide a Schedule Status Report on the day the job begins. If, in the opinion of the Contracting Officer, the Contractor falls behind the approved schedule, the Contractor shall take steps necessary to improve its progress including those that may be required by the Contracting Officer, without additional cost to the Government.\nProgress Meetings:\nThe Government and the Contractor shall meet daily (or as otherwise mutually agreed to) between the meetings described in paragraph Periodic Schedule Update Meetings for the purpose of jointly reviewing the actual progress of the project as compared to the as planned progress and to review planned activities for the upcoming two weeks. The then current and approved schedule update shall be used for the purposes of this meeting and for the production and review of reports. The Contractor's Project Manager and the Authorized Representative of the Contracting Officer shall attend. The weekly progress meeting will address the status of RFI's, RFP's and Submittals.\nThe contractor is responsible for recording Meeting Minutes for all official meetings with the Government and distributing them via email to the meeting participants, COR, and CO, within two (2) working days of the meeting.\nOfficial meetings include, but are not limited to security service coordination meetings, and any meeting the Contractor has with the Contracting Officer or COR regarding the Contract Quality or Performance.\n\nPayment and Invoicing:\nEach invoice will be processed for payment upon the completion of the project and all deliverables within the scope of work have been deemed accomplished by the COR.\nInvoices shall be billed over the course of the project lifespan. shall not be released until the COR deems the project is complete.\nProgressive invoice payments as directed by the COR and agreed upon by the Contractor.\n\nPerformance Monitoring - Routine inspections by Facilities Personnel:\nThe Government and the Contractor shall meet weekly (or as otherwise mutually agreed to) between the meetings described in paragraph Periodic Schedule Update for the purpose of jointly reviewing the actual progress of the project as compared to the as planned progress and to review planned activities for the upcoming two weeks. Then the current and approved schedule update shall be used for the purposes of this meeting and for the production and review of reports. The Contractor's Project Manager and the Authorized Representative of the Contracting Officer shall attend. The weekly progress meeting will address the status of RFI's, RFP's and Submittals.\nContractor Qualifications & Certification:\nTechnicians must be certified per NFPA 99 and Joint Commission as determined by the COR.\n\nIdentification, Parking Smoking and VHA Regulations\nContractor shall obtain a Contractor I.D. Badge from the VA Police. All Contractor personnel shall ALWAYS wear required visible identification issued by the VA Police during the entire time they are on the VA Healthcare System campus.\nThe COR is responsible for determining the type of Temporary ID badge that will be issued to the Contractor (including Sub-Contractors). All ID badges will be issued via the VHA Police.\nContractors (including Sub-Contractors) are required to wear Temporary ID Badges that are determined by the COR:\nOne to fourteen (1-14) day temporary\nFifteen (15) consecutive days or greater. A background check is required. In accordance with VHA Directive 0710 all Contractor personnel providing services under this contract shall be the subject to a background screening and must receive favorable adjudication from the VA prior to contract performance. The level of screening for this contract is: Special Agency Check. Any employee whose background investigation yields unfavorable results shall be removed immediately from performance under this contract. In the event the screening is not completed prior to contract performance, the Contractor shall be responsible for the actions of those individuals performing under the contract.\nParking information is available from the VA Police & Security Service Office. It is the responsibility of the Contractor to park only in appropriately designated parking areas. The VA shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\nSmoking is prohibited throughout the VA Healthcare System campus.\nPossession of weapons is prohibited while on the ANY VA Healthcare System campus. Enclosed containers, including tool kits, shall be subject to search / seizure.\nViolations of VA regulations may result in citation answerable in the United States Federal District Court, not at/in the local district, municipal, or state court.\n\nPersonnel Security Requirements:\nThe Office of Security and Law Enforcement provides Department-wide policy on the assignment of appropriate position sensitivity designations associated with Department of Veterans Affairs (VA) positions involving national security and public trust responsibilities, and on the level of background investigations required for applicants for, and incumbents of, those positions.\nThe cost for such investigations shall be borne by the Contractor, either in advance or as reimbursement to the Government. The Contractor shall be required to furnish all applicable employee information required to conduct the investigation, such as, but not limited to, the name, address, and social security number of the Contractor s personnel. The VA will provide all the necessary instructions and guidance for submission of the documents required to conduct the background investigation. Background investigations shall not be required for contract personnel assigned to Low Risk/Non-sensitive positions for 180 days or less under a single contract or series of contracts. However, a Security Access Clearance (SAC) background screening will be required for appropriate preliminary checks IAW VA Directive 0710.\n\nConformance Standards\nAll design and construction accomplished pursuant to this contract shall comply with the latest edition of the following documents unless the contractor is directed otherwise by the Contracting Officer. Any exceptions must be approved in writing by the Contracting Officer prior to construction startup.\nVA Master Construction Specifications\nhttps://www.cfm.va.gov/til/spec.asp#01\nVA Construction Standards\nVA Seismic Design Handbook\nVA Space Planning Criteria\nVA Design Manuals\nVA CADD Standards\nNFPA 101, Life Safety Code\nNFPA 110, Standard for Emergency Standby Power Systems\nNFPA 70, National Electric Code\nNFPA 99, Health Care Facilities\nNFPA 12, Installation of Sprinkler Systems\nAccessibility Standards (ADAAG, ABAAS, Barrier Free Design Guide)\nAIA Guidelines for Construction and Equipment of Hospital and Medical Facilities\nInternational Building Codes\nState and Local codes and guidelines (as applicable)\n\nInsurance Coverage:\nContractor agrees to procure and maintain, while the contract is in effect, Workers Compensation and Employee s Public Liability Insurance in accordance with Federal and State of California laws. The Contractor shall be responsible for all damage to property, which may be done by him, or any employee engaged in the performance of this contract.\nThe Government shall be held harmless against any or all loss, cost, damage, claim expense or liability whatsoever, because of accident or injury to persons or property of others occurring in the performance of this contract.\nBefore commencing work under this contract, the Contracting Officer shall require the Contractor to furnish certification from his/her insurance company indicating that the coverage specified by FAR 52.228-5 and per FAR Subpart 28.307-2 has been obtained and that it may not be changed or canceled without guaranteed thirty (30) day notice to the Contracting Officer.\nContractor is required to provide copies of proof of Workers Compensation and Employee Public Liability Insurance within fifteen (15) calendar days after notification of contract award.\n\nGovernment-Furnished Equipment / Government-Furnished Information:\nNo government equipment will be used by the awarded Contractors.\n\nRisk Control:\nIf applicable, the Contracting Officer s Representative will work with VHA Safety and Infection Control services to establish an Interim Life Safety Measures (ILSM) and Infection Control Risk Assessment (ICRA) that must be followed by the Contractor.\nVHA requires documentation of Tuberculosis (TB) risk assessment for contractors, and dependent on the project risk level, documentation of results of TB testing and follow-up of those with positive results. VHA Directive 2011-036.\n\nPlace of Performance:\nVHA Long Beach Healthcare System located at 5901 East 7th Street, Long Beach, CA, 90822.\nAll work shall be scheduled during normal work hours (7:00 AM to 4:30 PM) Monday Friday, Pacific Standard Time (PST), excluding Federal Holidays. Work shall not impact patient care services.\nWeekend (Saturday or Sunday) work must be approved by the COR assigned to the Task Order.\nAfter hours (6PM-6AM, Pacific Standard Time (PST)) work must be approved by the COR.\nAny overtime or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government.\nIf a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\nGovernment Holidays observed include:\nNew Year s Day .. ..\nJanuary 1st\nMartin Luther King s Birthday .. ....\nThird Monday in January\nPresidents Day .. .\nThird Monday in February\nMemorial Day . ..\nLast Monday in May\nIndependence Day\nJuly 4th\nLabor Day .. .. .\nFirst Monday in September\nColumbus Day ..\nSecond Monday in October\nVeterans Day .\nNovember llth\nThanksgiving Day ..\nFourth Thursday in November\nChristmas Day\n25 December\n\nPeriod of Performance:\n365 days post the Notice to Proceed (NTP) being issued to the Contractor.\n\nDelivery Schedule:\nContact the Contracting Officer s Representative (COR).","html":"This Modification is to update multiple items to the Sources sought.\n1). Change PCS Code from 6115 to J030.\n2). Change the NACIS code from 56163 to 811310.\n3). Change the close date from 07/14/2025 to 07/15/2025 at 3pm Mountain Time.\n\nTHIS REQUEST FOR INFORMATION (RFI) /SOURCES SOUGHT NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought Notice / RFI only.  The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 811310 (size standard of $12.5 Million Dollars). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.  \nThe Department of Veterans Affairs (VA) Long Beach Healthcare System is seeking sources capable of providing Annual Generator Preventative Maintenance for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System.\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. Please see the attached Statement of Work.\nIf your company is interested in and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SALIENT CHARACTERISTICS requirements.  For instances where your company cannot meet the SALIENT CHARACTERISTICS requirement(s), please explain.  For instances where your company can meet the SALIENT CHARACTERISTICS requirement(s), please show how your company meets/exceeds each requirement.  \n(2) Please review the list of SALIENT CHARACTERISTICS requirements and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SALIENT CHARACTERISTICS?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components?  Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution?  What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance?  Please specify what FDA clearance(s) have been obtained.\n(15) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(16) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(17) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(18) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Mark.Welshans@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Tuesday, July 15, 2025 by 15:00 PM  Local Time.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only.  Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement. \n\n\nVHA Long Beach Healthcare System                                                                         Engineering Service\nScope of Work \n\nIFCAP Tracking Number (2237):\n600-25-2-5665-0018\n\nContracting Officer s Representative (COR):  \nName        .\nSalvador Arceo\nService       ...\nEngineering Service\nAddress       ..\nVHA Long Beach Healthcare System                                                                         \n5901 East 7th Street, Long Beach, CA, 90822\nContact Information      .\nOffice: 562-826-8000, ext. 2985\nCellular: 562-721-8023\nEmail: Salvador.arceo@va.gov\n\nContract Title:  \nAnnual Generator Preventative Maintenance \n\nIntroduction & Background:    \nVA Long Beach Healthcare System (VALBHCS) located at 5901 East 7th Street, Long\nBeach, CA 90822-5201, has a requirement for annual generator systems preventative\nmaintenance services for twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System. Generators must be kept in optimal working condition to ensure correct and efficient operation as/when needed at/for the VA Long Beach Healthcare System. Services shall also comply with all VA, local, state, and Federal policies and regulations.\n\nGeneral Requirements:  \nAll work shall be completed at and provided throughout the VHA Long Beach Healthcare System located at 5901 East 7th Street, Long Beach, CA, 90822.\nContractor shall provide all Labor, Parts, Materials, Equipment, and Supervision\nrequired to perform all work.\nContractor (general or sub-contractor) is required to have completed and provide current safety training certifications:\nSuperintendent: 30-hours Construction Safety course.\nTradesmen: Occupational Safety and Health Administration (OSHA) 10-hour Construction Safety training\nContractor shall check-in with the Contracting Officer s Representative (COR) upon arrival at the VHA Long Beach Healthcare System. \nContractor shall wear all OSHA regulated and VHA Personal Protective Equipment (PPE). \nPrior to start of work, contractor personnel shall attend a safety briefing presenting by VA Long Beach safety Department.\nPrior to start of work, ALL energy sources (electrical, water, etc,) must be locked and tagged out, and upon completion of work, will be re-energized and verified.\nDuring the construction process the contractor must ensure safety and exclude the possibility of injury to patient, staff and visitors.  \nContractor will abide by all hospital policies for Infection Control Risk Assessment (ICRA) and Interim Life Safety Measures (ILSM) policies. Contractor will set up work area providing all barriers and protection needed to ensure safe removal and replacement of equipment and/or materials. \nHealthcare System Policy: Infection Prevention & Control Guidelines, Section One-22, Issue Date January 31, 2019, Construction, Renovation, Repair and Demolition \nHealthcare System Policy: Interim Life Safety Measure, Issue Date January 2020.\nDepending on the scope of work, to be defined in the Task Order, the Contract Officer s Representative and Contractor must attain and provide the correct type of permit required by VHA Safety Office. Work cannot commence until the appropriate work permit has been signed off by all parties. The following permits will apply depending on the scope of work:\nHot Work Permit\nAbove the Ceiling and Penetration Permit \nEnergized Electrical Permit\nUtility and Fire Alarm System Permit\nUtility Shutdown Permit \nCollect, contain and dispose of all debris daily and upon completion of work resulting from the overall scope of the project according to VHA Regulations.\nThe contractor is responsible for repairing damages incurred during performance of this scope of work to include removal/installation or moving materials and tools in and out of the work area.\nContractor shall provide the COR with a Master schedule with proposed days to start the PMs withing 7 days of awarded contract. \nContractor shall check-in with, notify, and coordinate ALL work activities through/with the VA Contracting Officer Representative (COR) or designee   prior to scheduling and/or performing any work.\nThe contractor shall provide the COR with a copy of the service report of the service provided for each generator after every service is completed. This will include the name, serial number, model, date and services provided.\n\nScope of Work\n\nThe purpose of this contract is to have a Contractor furnish all equipment, expertise, incidentals, labor, materials, parts, supervision, supplies, tools, and qualified personnel to perform the annual generator systems preventative maintenance services for/on twelve (12) generators and twenty-two (22) ATS s that provide back-up power for the Emergency Electrical Distribution System. Services performed shall conform to industry standards and this statement of work (SOW), and lockout-tagout procedures are to be done in accordance with OSHA Standard 29 CFR 1910.147 and VALBHCS policies and regulations.\nThe Contractor is responsible to provide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance of each generator stations as required.\n\nAnnual Service Required but not limited to: (Please See specific task for additional requirements)\n\nCheck fuel and oil levels. Check for leaks. \nInspect air cleaner elements. Clean as required. Inspect crankcase breathers and note any excessive blow-by.\nInspect turbocharger rotation and end play.\nInspect hose s for security, brittleness, cracking, leaks, and weaknesses. Check all hose clamps and tighten as required.\nInspect fans and alternator belts for proper tension and condition. Adjust as required. (Base year belts are replaced)   \nInspect day tank, piping, motors, and levels. Check for leaks. Service fuel/water separators and replace fuel filters.\nInspect batteries, cables and lugs for tightness. Replace batteries annually and fill cells as required. Record battery cells specific gravities. Check for correct electrolyte level. Record DC voltage power supply. Inspect battery charger and record DC voltage power supply.\nInspect engine control panel for loose connections. Tighten as required.\nInspect the jacket water heater for the correct operation.\nInspect water pumps for leaks and/or unusual noises.\nInspect governor and engine controls. Inspect controls and linkage for proper operation. Add lube oil as necessary.\nTest all engine safety shutdown pre-alarms and alarms.\nInspect radiator for leaks and clogged ends. Check cooling systems for anti-freeze and Nalcool protection. Add water and anti-freeze as required for safe engine operation.\nStart engine and warm up. Record operation. Adjust RPM as required. Check for fluid leaks. Check all instruments for proper\noperation.\nChange oil and oil filters.\nTake oil sample for analysis.\nChange fuel filters on the generator.\nInspect junction boxes for loose connections. Tighten as required.\nInspect generator brushes for proper setting and clean slip rings. Lubricate generator bearings.\nInspect and clean generator exciter and regulator. Check for loose connections \nChange air filters\nReplace all batteries\n\n\nSPECIFIC TASKS:\nBATTERIES:\nStarting batteries shall be removed and replaced with new batteries.\nCheck battery chargers for proper algorithm, voltage, and current output.\nFUEL SYSTEM:\nAbove ground diesel tanks and lines shall be inspected for defects.\n\nENGINE:\nCheck for fuel, oil and/or coolant leaks, and tighten all bolts, nuts and retaining devices as necessary.\nGovernor system and linkage shall be checked for binding and proper operation.\nInspect overall condition of air intake and exhaust system.\nAir filters shall be removed and replaced.\nEngine block heater(s) and associated plumbing shall be checked for proper operation.\nBase year all belts shall be changed. Subsequent years, belts shall be checked for proper tension and signs of age, wear, and tear.\nInspect all wiring, cabling, and connections for any corrosion, abrasion, chaffing, or breaks.\nCheck alternator for overall condition and proper current charge output.\nCheck the overall condition of starter.\nCheck and inspect overall condition of equipment for obstructions, debris, and corrosion.\nClean as required.\n\nCOOLING SYSTEM:\nBase year, coolant and radiator caps shall be replaced with new.\nSubsequent years, coolant shall be tested for proper mixture with a coolant test strip.\nRadiator shall be checked externally for debris, leaks, and/or corrosion.\nRadiator cap shall be checked for proper seal.\nAll cooling system hoses shall be checked and tightened.\nCheck coolant system levels and add necessary fluid as required.\n\nGENERATOR CONTROLLER:\nCheck electrical connections and wiring for any corrosion, abrasion, chaffing, and breaks.\nTighten all electrical connections.\nCheck switches and gauges.\nCheck panel lights.\n\nMAINTENANCE SERVICE:\nPerform inspections as noted above.\nChange engine lubricating oil and oil filters.\nChange fuel filters.\nChange water filters and coolant conditioners when used.\nObtain oil samples for analysis by fluid testing Laboratories.\nDispose of maintenance service hazardous waste at an approved disposal site.\nObtain coolant sample for analysist by fluid testing Laboratories and provide report.\nRun generator for thirty (30) minutes after all maintenance is complete to check operation of engine.\nProvide written report of all checked systems, anomalies detected, maintenance accomplished / performed, and recommendations for further maintenance / repairs.\n\nATS Preventative Maintenance Cleaning & Transfer Test\nComplete visual inspection or wiring/connections for tracking, overheating and insulation deterioration.\nVisually inspect for physical damage, anchorage, and grounding.\nVerify NPA is operational (normal power available).\nVisually inspect control wiring.\nVerify EPA light is operational (emergency power available).\nPerform ATS Transfer Test to ensure communication between utility power & ATS. (if allowed by facility)\nIf ATS Test is performed, then verify test light is lit (not present with all ATS)\nCheck and record normal and emergency source voltages\nInspect Solid State Controls for cleanliness and serviceability.\nShut down power and deenergize the ATS (everything that is backed up by the ATS will be down, unless you have an isolation bypass ATS).\nClean, lubricate and inspect transfer mechanism, check alignment, and manually operate in accordance with manufacturers' instructions.\nCheck switch to ensure positive interlock between normal and alternate sources.\nCheck bypass and isolation features, if applicable.\nCheck tightness of all de-energized cable connections and bus and joints.\nAll arc chutes and pole covers are removed and cleaned. Main current carrying contacts inspected for water.\nControl wiring is inspected, and all electrical connections checked for tightness.\nPerform contact resistance tests with switch in both source positions.\nMonitor and verify correct operation and timing for the following:\n\n  Normal voltage sensing relays (if any)\n\n  Engine start sequence\n\n  Time delay upon transfer\n\n  Alternate voltage sensing relay\n\n  Automatic transfer operation\n\n  Interlocks and limit switch function\n\n  Timing delay and retransfer upon normal power restoration\n\nEQUIPMENT TO BE COVERED / SERVICED:\nGENERATOR 5: CUMMINS ONAN 250KW (1 ATS)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll Work can be completed during normal business hours, M-F 8:00AM-4:00PM.\nGENERATOR 5A: CUMMINS ONAN 600KW (2 ATS s- 1 in Bldg 5b)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 5B-1: CATERPILLAR 2.5MW \nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 5B-2: CATERPILLAR 2.5MW \nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 5B-3: CATERPILLAR 2.5MW\nPerform all annual maintenance service as identified / listed / stated above.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 126: CUMMINS ONAN 1000KW (6 ATS s- 2 in Bldg 165)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\nGENERATOR 126O/P: CUMMINS ONAN 600KW (4 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\nGENERATOR 133: CUMMINS ONAN 400KW (1 ATS)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 138: CUMMINS ONAN 500KW (3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nB. Provide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nC. All work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\n\nGENERATOR 150: CUMMINS ONAN 360KW (3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed during normal business hours, M   F 8:00AM   4:00PM.\nGENERATOR 164: DETROIT DIESEL 500KW  ( 3 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\nGENERATOR 149: CUMMINS 50KW ( 1 ATS s)\nPerform all annual maintenance service as identified / listed / stated above.\nProvide temporary generator, cabling, hook-ups, and cabling ramps needed for emergency back-up during maintenance.\nAll work can be completed SATURDAY OR SUNDAY between 7:00AM   4:00PM.\n\nContract Modifications:\nModifications for this project must be submitted to the assigned COR who will then submit a formal request to the Contracting Officer (CO). New work is not allowed to commence prior to Contracting Officer s signed and written approval via fully executed Standard Form (SF) 30 modification.\nThe Modification is considered official only when the Contracting Officer and Contractor sign the Modification and the CO provides all parties a copy of the contract Modification. \n\nScheduled Status Reports:\nStatus the schedule and provide a Schedule Status Report on the day the job begins. If, in the opinion of the Contracting Officer, the Contractor falls behind the approved schedule, the Contractor shall take steps necessary to improve its progress including those that may be required by the Contracting Officer, without additional cost to the Government.  \nProgress Meetings:\nThe Government and the Contractor shall meet daily (or as otherwise mutually agreed to) between the meetings described in paragraph Periodic Schedule Update Meetings for the purpose of jointly reviewing the actual progress of the project as compared to the as planned progress and to review planned activities for the upcoming two weeks. The then current and approved schedule update shall be used for the purposes of this meeting and for the production and review of reports. The Contractor's Project Manager and the Authorized Representative of the Contracting Officer shall attend. The weekly progress meeting will address the status of RFI's, RFP's and Submittals.\nThe contractor is responsible for recording Meeting Minutes for all official meetings with the Government and distributing them via email to the meeting participants, COR, and CO, within two (2) working days of the meeting. \nOfficial meetings include, but are not limited to security service coordination meetings, and any meeting the Contractor has with the Contracting Officer or COR regarding the Contract Quality or Performance.\n\nPayment and Invoicing:\nEach invoice will be processed for payment upon the completion of the project and all deliverables within the scope of work have been deemed accomplished by the COR. \nInvoices shall be billed over the course of the project lifespan. shall not be released until the COR deems the project is complete.  \nProgressive invoice payments as directed by the COR and agreed upon by the Contractor.  \n\nPerformance Monitoring - Routine inspections by Facilities Personnel:\nThe Government and the Contractor shall meet weekly (or as otherwise mutually agreed to) between the meetings described in paragraph Periodic Schedule Update for the purpose of jointly reviewing the actual progress of the project as compared to the as planned progress and to review planned activities for the upcoming two weeks. Then the current and approved schedule update shall be used for the purposes of this meeting and for the production and review of reports. The Contractor's Project Manager and the Authorized Representative of the Contracting Officer shall attend. The weekly progress meeting will address the status of RFI's, RFP's and Submittals.\nContractor Qualifications & Certification:\nTechnicians must be certified per NFPA 99 and Joint Commission as determined by the COR. \n\nIdentification, Parking Smoking and VHA Regulations \nContractor shall obtain a  Contractor I.D. Badge  from the VA Police. All Contractor personnel shall ALWAYS wear required visible identification issued by the VA Police during the entire time they are on the VA Healthcare System campus.\nThe COR is responsible for determining the type of Temporary ID badge that will be issued to the Contractor (including Sub-Contractors). All ID badges will be issued via the VHA Police. \nContractors (including Sub-Contractors) are required to wear Temporary ID Badges that are determined by the COR: \nOne to fourteen (1-14) day temporary \nFifteen (15) consecutive days or greater.  A background check is required. In accordance with VHA Directive 0710 all Contractor personnel providing services under this contract shall be the subject to a background screening and must receive favorable adjudication from the VA prior to contract performance. The level of screening for this contract is: Special Agency Check. Any employee whose background investigation yields unfavorable results shall be removed immediately from performance under this contract. In the event the screening is not completed prior to contract performance, the Contractor shall be responsible for the actions of those individuals performing under the contract.\nParking information is available from the VA Police & Security Service Office. It is the responsibility of the Contractor to park only in appropriately designated parking areas. The VA shall not validate or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\nSmoking is prohibited throughout the VA Healthcare System campus.\nPossession of weapons is prohibited while on the ANY VA Healthcare System campus. Enclosed containers, including tool kits, shall be subject to search / seizure.\nViolations of VA regulations may result in citation answerable in the United States Federal District Court, not at/in the local district, municipal, or state court.\n\nPersonnel Security Requirements:\nThe Office of Security and Law Enforcement provides Department-wide policy on the assignment of appropriate position sensitivity designations associated with Department of Veterans Affairs (VA) positions involving national security and public trust responsibilities, and on the level of background investigations required for applicants for, and incumbents of, those positions.\nThe cost for such investigations shall be borne by the Contractor, either in advance or as reimbursement to the Government. The Contractor shall be required to furnish all applicable employee information required to conduct the investigation, such as, but not limited to, the name, address, and social security number of the Contractor s personnel. The VA will provide all the necessary instructions and guidance for submission of the documents required to conduct the background investigation. Background investigations shall not be required for contract personnel assigned to Low Risk/Non-sensitive positions for 180 days or less under a single contract or series of contracts. However, a Security Access Clearance (SAC) background screening will be required for appropriate preliminary checks IAW VA Directive 0710.\n\nConformance Standards \nAll design and construction accomplished pursuant to this contract shall comply with the latest edition of the following documents unless the contractor is directed otherwise by the Contracting Officer. Any exceptions must be approved in writing by the Contracting Officer prior to construction startup.\nVA Master Construction Specifications\nhttps://www.cfm.va.gov/til/spec.asp#01\nVA Construction Standards\nVA Seismic Design Handbook\nVA Space Planning Criteria\nVA Design Manuals\nVA CADD Standards\nNFPA 101, Life Safety Code\nNFPA 110, Standard for Emergency Standby Power Systems\nNFPA 70, National Electric Code\nNFPA 99, Health Care Facilities\nNFPA 12, Installation of Sprinkler Systems\nAccessibility Standards (ADAAG, ABAAS, Barrier Free Design Guide)\nAIA Guidelines for Construction and Equipment of Hospital and Medical Facilities\nInternational Building Codes\nState and Local codes and guidelines (as applicable)\n\nInsurance Coverage: \nContractor agrees to procure and maintain, while the contract is in effect, Workers Compensation and Employee s Public Liability Insurance in accordance with Federal and State of California laws. The Contractor shall be responsible for all damage to property, which may be done by him, or any employee engaged in the performance of this contract.\nThe Government shall be held harmless against any or all loss, cost, damage, claim expense or liability whatsoever, because of accident or injury to persons or property of others occurring in the performance of this contract.\nBefore commencing work under this contract, the Contracting Officer shall require the Contractor to furnish certification from his/her insurance company indicating that the coverage specified by FAR 52.228-5 and per FAR Subpart 28.307-2 has been obtained and that it may not be changed or canceled without guaranteed thirty (30) day notice to the Contracting Officer.\nContractor is required to provide copies of proof of Workers Compensation and Employee Public Liability Insurance within fifteen (15) calendar days after notification of contract award.\n\nGovernment-Furnished Equipment / Government-Furnished Information:  \nNo government equipment will be used by the awarded Contractors.\n\nRisk Control:\nIf applicable, the Contracting Officer s Representative will work with VHA Safety and Infection Control services to establish an Interim Life Safety Measures (ILSM) and Infection Control Risk Assessment (ICRA) that must be followed by the Contractor. \nVHA requires documentation of Tuberculosis (TB) risk assessment for contractors, and dependent on the project risk level, documentation of results of TB testing and follow-up of those with positive results. VHA Directive 2011-036.\n\nPlace of Performance:\nVHA Long Beach Healthcare System located at 5901 East 7th Street, Long Beach, CA, 90822.  \nAll work shall be scheduled during normal work hours (7:00 AM to 4:30 PM) Monday   Friday, Pacific Standard Time (PST), excluding Federal Holidays. Work shall not impact patient care services.  \nWeekend (Saturday or Sunday) work must be approved by the COR assigned to the Task Order.\nAfter hours (6PM-6AM, Pacific Standard Time (PST)) work must be approved by the COR.\nAny overtime or holiday pay that may be entitled to the Contractor s employees shall be the sole responsibility of the Contractor and shall not be billed to nor reimbursed by the Government. \nIf a holiday falls on Sunday, the following Monday shall be observed as the legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\nGovernment Holidays observed include:\nNew Year s Day        .. ..\nJanuary 1st\nMartin Luther King s Birthday ..  ....                          \nThird Monday in January\nPresidents Day     ..    . \nThird Monday in February\nMemorial Day         . ..\nLast Monday in May\nIndependence Day         \nJuly 4th\nLabor Day        .. ..  .\nFirst Monday in September\nColumbus Day          ..\nSecond Monday in October\nVeterans Day           .\nNovember llth\nThanksgiving Day         ..\nFourth Thursday in November\nChristmas Day            \n25 December\n\nPeriod of Performance:\n365 days post the Notice to Proceed (NTP) being issued to the Contractor. \n\nDelivery Schedule:\n       Contact the Contracting Officer s Representative (COR).","origin":"detail"},"contacts":[{"name":"Mark Welshans","role":"primary","email":"Mark.Welshans@va.gov","phone":"520-792-1450 x16066","title":"Contract Specialist"}],"place_of_performance":{"zip":"90822","city":{"name":"Long Beach"},"state":{"name":"CA"},"street":"VHA Long Beach Health Care System","street2":"Department of Veterans Affairs 5901 East 7th Street"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"03d87e99358b4aef8256ff936ad0e744","name":"36C26225Q1105.docx","kind":"file","mime_type":".docx","size_bytes":19617,"posted_at":"2025-07-02T13:52:33.661Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/03d87e99358b4aef8256ff936ad0e744/download","mirrored":false}],"awards":[],"related":[{"key":"36C26227Q0085","latest_notice_id":"cdde3a94bda84b199f9d3db72af657a6","title":"S215--SDVOSB Furniture Installation Labor Storage - Base Plus Four Option Years | POP: (12/31/2026 - 12/30/2031) |","solicitation_number":"36C26227Q0085","notice_type":"o","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-23","notices":4,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"493190","psc":"S215","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C26227Q0079","latest_notice_id":"00646e7746494ab38ce53bbe9f7e0f59","title":"W065--RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT","solicitation_number":"36C26227Q0079","notice_type":"k","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-26T20:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"532490","psc":"W065","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0139","latest_notice_id":"156fef93406e495486eb1d4e805bb675","title":"6515--PYXIS IV PREP","solicitation_number":"36C26227Q0139","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541519","psc":"6515","set_aside":"SDVOSBC","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26227Q0146","latest_notice_id":"e2fc7d7b106d4b448a5b57cba568ddb4","title":"J041--KITCHEN HOOD PMIR - Base +4 ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0146","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"561790","psc":"J041","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T08:15:06.508374Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open":[{"key":"W912PL27QA001","latest_notice_id":"55fd39a8c25743939ed3ffe95d292b4e","title":"Material Handling Equipment (MHE) and Industrial Equipment (IE) Maintenance and Repair Services","solicitation_number":"W912PL27QA001","notice_type":"k","first_type":"k","first_posted":"2026-10-23","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-27T22:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","naics":"811310","psc":"J039","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"SOUTH EL MONTE, CA 91733","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0107","latest_notice_id":"6a5b19d6e316483386c61a63f786b4fa","title":"J041--VA Long Beach Healthcare System (VALBHS) Recurring Maintenance for Metasys Building Automation System and four (4) YORK Chillers","solicitation_number":"36C26227Q0107","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"811310","psc":"J041","set_aside":null,"state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C26127Q0169","latest_notice_id":"9989888cf8614c8e87f9894ee00a31e7","title":"J012--Dry-Type Fire Suppression System","solicitation_number":"36C26127Q0169","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-30T23:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"811310","psc":"J012","set_aside":null,"state":"CA","county":"06085","county_name":"Santa Clara County","city":"0655282","city_name":"Palo Alto","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":57,"indexable":false}