{"canonical":"https://sealedbidder.com/opportunities/36c26225q1021","key":"36C26225Q1021","url":"https://sealedbidder.com/opportunities/36c26225q1021","title":"6515--Ultrasonic Cleaning System","solicitation_number":"36C26225Q1021","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-06-20T17:00:00Z","first_posted":"2025-06-12","last_posted":"2025-06-12","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"339113","psc":"6515","set_aside":null,"place_state":"CA","place_scope":"nationwide","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"06073","place_county_name":"San Diego County","place_city":"0666000","place_city_name":"San Diego","winner":null,"award_amount":null,"publications":[{"notice_id":"2aa4aed7860d4af688e4008688bf9aa5","title":"6515--Ultrasonic Cleaning System","solicitation_number":"36C26225Q1021","notice_type":"r","base_type":"r","posted":"2025-06-12","posted_at":"2025-06-12T19:13:13.677Z","due_at":"2025-06-20T17:00:00Z","due_date":"2025-06-20","cancelled":false,"archived":true,"archive_date":"2025-07-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2aa4aed7860d4af688e4008688bf9aa5/view","enriched":true,"history":[{"index":3,"title":"6515--Ultrasonic Cleaning System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-12T19:13:13.677Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2aa4aed7860d4af688e4008688bf9aa5","solicitation_number":"36C26225Q1021"}]}],"latest_notice_id":"2aa4aed7860d4af688e4008688bf9aa5","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-06-12","posted_at":"2025-06-12T19:13:13.677Z","created_at":"2025-06-12T19:13:11.464Z","modified_at":"2025-07-21T04:00:14.499Z","response_deadline":{"raw":"2025-06-20T10:00:00-07:00","utc":"2025-06-20T17:00:00Z","date":"2025-06-20","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2aa4aed7860d4af688e4008688bf9aa5/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--Ultrasonic Cleaning System","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-20","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Ultrasonic Cleaning System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-06-12T19:13:13.677Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2aa4aed7860d4af688e4008688bf9aa5","solicitation_number":"36C26225Q1021"}],"contacts":[{"name":"Hestia Sim","role":"primary","email":"Hestia.Sim@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"2aa4aed7860d4af688e4008688bf9aa5","lineage_id":"2aa4aed7860d4af688e4008688bf9aa5","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-12T15:04:46.605844085Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"cde28f493642b4e9f0a92e1443e5b72c464d11cf1cd8a47c0c07ed857183fd87","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-12T15:04:46.605844085Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS REQUEST FOR INFORMATION (RFI) /Â SOURCES SOUGHT NOTICE IS ISSUEDÂ  SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought Notice / RFI only.  The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.  \nThe Department of Veterans Affairs (VA) is seeking sources capable of providing Ultrasonic Cleaning System in accordance with following Statement of Work.\n\nSTATEMENT OF WORK\n\nGENERAL\n\nThe Department of Veterans Affairs (VA), Network Contracting Office 22, requires Sterile Processing Equipment for the Sterile Processing Services (SPS) at the Jennifer Moreno VA Medical Center located in San Diego, California.  \n\nBACKGROUND\n\nThe VA San Diego Healthcare System (VASDHCS) requires the procurement and installation of (2) large-capacity, floor-model ultrasonic cleaners, (1) compact tabletop ultrasonic cleaning system, and (1) single-tank floor-mounted ultrasonic cleaning system for SPS.\n\nVASDHCS requires a Contractor to provide the SPS equipment specified in this statement of work and coordinate efforts with SPS staff and contracting personnel to ensure equipment is installed and functional.\n\nThe Contractor shall provide all labor, materials, equipment, transportation, installation, and supervision necessary to satisfy the requirement.\n\nGENERAL REQUIREMENTS\n\nPLACE OF PERFORMANCE:\nVA San Diego Healthcare System\n3350 La Jolla Village Drive,\nSan Diego, CA 92161\nBldg 1, Sterile Processing Service Decon, Rm B191K\n\nDELIVERABLES\n\nThe Contractor shall provide the following:\n\nCLIN\nDescription\nQuantity\nUOM\n0001\nGetinge Triton 72 Floor Model Ultrasonic Cleaning System or equivalent Ultrasonic Cleaner with large capacity to reprocess complex surgical instruments trays\n2\nEA\n0002\nGetinge 1100 Ultrasonic Cleaning or equivalent Compact Tabletop Ultrasonic Cleaner\n1\nEA\n0003\nGetinge Ultrasonic Cleaner 2460C or equivalent Single-Tank Ultrasonic Cleaner\n1\nEA\n0004\nSeismic Anchoring\n4\nEA\n0005\nInstallation and Training\n1\nJB\n0006\nDe-installation of old total three equipment and dispose of two out of three equipment deinstalled.\n1\nJB\n\nNOTE: Potential offers must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are  or equal , a description of the salient characteristics is outlined below. The FAR Clause 52.211-6 Brand Name or Equal applies to this acquisition. Offeror quotations must demonstrate meeting the salient physical, and functional characteristics included in this solicitation, otherwise, they will be considered non-responsive and not considered for award.\nNo remanufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM signed. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contain the signature of an authorized official for the manufacturer.\n\nSALIENT CHARACTERISTICS   Large Capacity Ultrasonic Cleaner Triton 72\n\nThe Sterile Processing Service requires ultrasonic cleaning systems for cleaning and disinfecting of instruments to clean and remove debris from instrumentation.\n\nMust have a minimum of 30-gallon capacity per basin.\nMust have a minimum of 2 basins per unit.\nMust have a minimum of 8 to 13 minutes ultrasonic cleaning cycles for laparoscopic and non-lumen instruments.\nMust have Ultrasonic cavitation cycle designed for removal of blood and debris from lumened instruments.\nMust be able to clean robotic instruments such as da Vinci SP and DV5 in accordance with Intuitive Surgical  s Instructions for Use (IFU). This cleaning function must be a minimum of 15-minutes.\nMust be able to clean a minimum of 40 da Vinci Robotic Instruments in one cycle.\nMust have a minimum of 72 dedicated irrigation ports.\nMust have a minimum of 12 ports/tray.\nMust be able to process a minimum of 10 robotic or lumen instruments.\nMust be able to cleanse up to a minimum of 4 lumen/standard instrument trays simultaneously, split equally independently per operable basins.\nMust have a minimum of 30  pull-down sprayer faucet for external rinsing of instruments.\nMust have an automatic powered lid opening and load tray elevator.\nMust have slide and lock mechanism for loading of trays.\nMust have a minimum of 6-tray capacity.\nMust have ultraviolet germicidal system to remove and deactivate microorganisms such as bacteria, fungi, and viruses.\nMust be able to support a minimum of total 80-lb instrument weight capacity, a minimum of 40lbs each basin.\nElectrical voltage must be 208-volt wall receptacle.\nUnit dimension must not exceed 33-3/8 W x 49-11/16 D x 67-1/2 H at rest, open position due to limited staging/operating space.\nMust include a rotating and adjustable screen display to allow users of varying height to easily view pertinent operating information during use.\nMust have fully automatic wash, flush, internal wash, external wash, air purge cycles, and drain.\nMust have Tap, RO, DI water compatible.\nMust have an automatic lifts and slide-lock trays.\nMust have ultraviolet germicidal system.\nMust not have degassing for optimal cleaning process.\nMust come with seismic anchoring.\n\nSALIENT CHARACTERISTICS   Compact Countertop Ultrasonic Cleaner 1100\n\nMust offer adjustable cycle time up to 10-minutes; allowing users to comply with different instrument manufacturer s IFU.\nMust be able to process both lumen and non-lumen instruments in the same cycle simultaneously.\nMust have a minimum of 12.5-lb total instrument weight capacity\nMust be equipped with 8 piezoelectric bonded transducers to ensure sensing heat level meets the minimum temperature to break bioburden in the RMD instruments.  \nMust have adjustable irrigation allowing users to control water flow for multiple instrument types\nMust have a minimum of 12 dedicated irrigation ports for lumen instrument cleaning.\nMust works with or without irrigation.\nMust have graphical touchscreen display with programmable timer.\nMust have a Bi-fold lid allowing placement beneath overhead cabinets.\nMust have a minimum of 2 shelves for supplies\nMust have automatic fill, wash, and drain functions.\nMust have automatic degas\nMust be tap, reverse osmosis, and deionized water compatible.\nMust have a minimum of 5.75-gallon basin capacity.\nMust have 120-volt wall receptacle.\nMust not exceed overall dimension of 32-1/2 W x 18-3/4 D x 17-9/16 H (lid open) due to limited space.\nMust accept hospital trays without irrigation.\nMust come with seismic anchoring.\n\nMINIMUM SALIENT CHARACTERISTICS   Single-Tank Floor-Mounted UC 2460\n\nMust have hands-free starting and stopping of cycle.\nMust have powered load tray elevator with safe lifting capacity of up to 35 lbs.\nMust have free moving lid that automatically closes and opens with tray elevator action; lid must not be fixed but moves freely and is automatically operated in conjunction with the tray elevator.\nMust be stainless steel construction of exterior panels and sonic cleaning chamber for durability, ease of cleaning, and resistance to corrosion.\nMust include a common operating control for start/stop functions, drain and system alarm accessible via the external back display panel due to the separation of clean and dirty sides of Sterile Processing.  The start/stop function is needed on the back panel, which is on the dirty side.  Any draining need to happen on the decontamination area and the employees need to be able to control those functions. \nProgramming buttons, controls for process time, detergent dispensing must be located within the unit to help safeguard unauthorized changes to the program parameters.\nMust have a minimum of 5  external back panel as a splash guard to prevent process water from getting onto the wall.\nMust have marine edges to keep process water from spilling onto the floor as trays are removed from the unit.\nMust include a hinged cover designed to minimize the overhead clearance required for chamber access.\nThe cover must fold or lay flat against the machine s surface to prevent processing water from splashing outside the unit.\nLid must be double pan construction with insulation between pans. Due to the strength/hazard of the detergents used to break down and clean any bioburden on the instrument trays, the equipment must have a safety mechanism to help contain the detergent and not easily breakdown the glass plan that separates the clean and dirty sides.\nMust have automatic detergent fill; allowing users to press  start  to press cycle so the system detects how much detergent is needed for the process.\nMust have a low liquid level sensor to assure the heaters are covered with water.\nMust have a high liquid level sensor provided to assure proper liquid level depth for ultrasonic cleaning.\nMust have built-in overflow protection to drain basin.\nMust have automatic cycle start and stop.\nMust have an audible cycle alarm to signal the start/end of a cycle\nMust have automatic cycle timers to allow specific instrument trays to complete a cycle.\nMust have a thermostat that automatically controls heater and maintains tank solution at pre-set temperature.\nMust have a controller that automatically dispenses pre-set amount of sonic detergent into the water as the tank fills.\nMust have low detergent indicator display.\nMust have automatic drain function.\nSafety door interlock to cut power when access door is opened, causing the elevator to lower, lid to close, and unit to drain\nDimensions must not exceed 33 1/2   L x 27 Â½  W x 41 H due to limited space.\nChamber overall dimension must be a minimum of 13  x 15  x 27 .\nMust be able to clean and disinfect with hospital grade disinfectants.\nMust meet electrical supply of 220 1-ph 50-60hz, 6.2 full load amps.\nMust include manual and motorized position locking capabilities.\nMust have a minimum of 62.5-Liter Capacity.\nMust come with Seismic anchoring.\n\n\nIMPLEMENTATION AND INSTALLATION \n\nInstallation and validation shall be included in the procurement cost and shall include but not limited to: \nAssembly of devices and validation\nAll materials required to assemble the ultrasonic shall be provided by the contractor\nThe contractor will deliver ultrasonic cleaning systems and accessories to: \n3350 La Jolla Village Dr, San Diego, CA  92161-0002, BLDG 1, Room B191K\nInstallation must occur during normal working hours: Monday through Friday 8:00am   3:00pm.\n\nTRAINING\n\nThe contractor shall provide onsite training for all MWV VAMC staff that requires training. Training shall be set up between SPS educator and contractor on a mutually agreed upon time and date.\n\nDELIVERY\n\nThe contractor shall deliver necessary equipment to the San Diego VA Medical Center facility as required in the quantities specified above. \nThe contractor must give VAMC staff 3 weeks  notice of shipment and delivery of the ultrasonic and accessories.  \nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box. \nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMC facilities.  \nDelivery Address:\n3350 La Jolla Village Dr, San Diego, CA  92161-0002, BLDG 1, West Dock\n\n\nINSPECTION AND ACCEPTANCE\n\nThe contractor shall conduct a joint inspection with the COR upon delivery of equipment. \nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\n\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format.\nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted.\nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities.\nThe assembly and validation of the system must be performed by the technician who are either Original Equipment Manufacturer (OEM) certified or has been formally trained and approved by OEM.\nThe contractor is responsible for identifying any missing parts or components not included in the order for the ultrasonic systems to be successfully installed and validated to their full potential and full function listed under the Statement of Work.\n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to MWV clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the MWV clinical staff after delivery and installation. \n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. \nThe contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor. \n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff. \nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement. \n\nWARRANTY\nAt a minimum the ultrasonic cleaning systems must include a 1-year warranty on all parts and labor at no cost to the Government. \nThe warranty shall begin upon completion of validation testing and approved by the COR.\nWarranty shall include on-site repairs and over-the-phone support. \nContractor shall provide routine maintenance service program during warranty period. Routine maintenance includes daily, weekly, and monthly maintenance. \nWarranty and routine maintenance shall include contractor s responsibility of draining and cleaning of basin, cleaning of the external surfaces, inspecting electrical connections, cleaning water level sensors, cleaning filter screens, checking and replacing drain screen, checking all plumbing connections, and checking peristaltic pump and tubing for cracks or leaks.\nAll repairs shall be performed by the OEM or contractors that have been certified and approved by the OEM to perform the repairs. \nThe warranty shall include all travel and shipping costs associated with any warranty repair. \n\n\n\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. \nIf your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SOW requirements.  For instances where your company cannot meet the SOW requirement(s), please explain.  For instances where your company can meet the SOW requirement(s), please show how your company meets/exceeds each requirement.  \n(2) Please review the list of SOW requirements and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SOW?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components?  Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution?  What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance?  Please specify what FDA clearance(s) have been obtained.\n(15) Does your organization offer a leasing solution?  Please elaborate.\n(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Friday, June 20, 2025, by 10AM Pacific Local Time.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only.  Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.  If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","text":"THIS REQUEST FOR INFORMATION (RFI) /Â SOURCES SOUGHT NOTICE IS ISSUEDÂ SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA) is seeking sources capable of providing Ultrasonic Cleaning System in accordance with following Statement of Work.\n\nSTATEMENT OF WORK\n\nGENERAL\n\nThe Department of Veterans Affairs (VA), Network Contracting Office 22, requires Sterile Processing Equipment for the Sterile Processing Services (SPS) at the Jennifer Moreno VA Medical Center located in San Diego, California.\n\nBACKGROUND\n\nThe VA San Diego Healthcare System (VASDHCS) requires the procurement and installation of (2) large-capacity, floor-model ultrasonic cleaners, (1) compact tabletop ultrasonic cleaning system, and (1) single-tank floor-mounted ultrasonic cleaning system for SPS.\n\nVASDHCS requires a Contractor to provide the SPS equipment specified in this statement of work and coordinate efforts with SPS staff and contracting personnel to ensure equipment is installed and functional.\n\nThe Contractor shall provide all labor, materials, equipment, transportation, installation, and supervision necessary to satisfy the requirement.\n\nGENERAL REQUIREMENTS\n\nPLACE OF PERFORMANCE:\nVA San Diego Healthcare System\n3350 La Jolla Village Drive,\nSan Diego, CA 92161\nBldg 1, Sterile Processing Service Decon, Rm B191K\n\nDELIVERABLES\n\nThe Contractor shall provide the following:\n\nCLIN\nDescription\nQuantity\nUOM\n0001\nGetinge Triton 72 Floor Model Ultrasonic Cleaning System or equivalent Ultrasonic Cleaner with large capacity to reprocess complex surgical instruments trays\n2\nEA\n0002\nGetinge 1100 Ultrasonic Cleaning or equivalent Compact Tabletop Ultrasonic Cleaner\n1\nEA\n0003\nGetinge Ultrasonic Cleaner 2460C or equivalent Single-Tank Ultrasonic Cleaner\n1\nEA\n0004\nSeismic Anchoring\n4\nEA\n0005\nInstallation and Training\n1\nJB\n0006\nDe-installation of old total three equipment and dispose of two out of three equipment deinstalled.\n1\nJB\n\nNOTE: Potential offers must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are or equal , a description of the salient characteristics is outlined below. The FAR Clause 52.211-6 Brand Name or Equal applies to this acquisition. Offeror quotations must demonstrate meeting the salient physical, and functional characteristics included in this solicitation, otherwise, they will be considered non-responsive and not considered for award.\nNo remanufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM signed. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contain the signature of an authorized official for the manufacturer.\n\nSALIENT CHARACTERISTICS Large Capacity Ultrasonic Cleaner Triton 72\n\nThe Sterile Processing Service requires ultrasonic cleaning systems for cleaning and disinfecting of instruments to clean and remove debris from instrumentation.\n\nMust have a minimum of 30-gallon capacity per basin.\nMust have a minimum of 2 basins per unit.\nMust have a minimum of 8 to 13 minutes ultrasonic cleaning cycles for laparoscopic and non-lumen instruments.\nMust have Ultrasonic cavitation cycle designed for removal of blood and debris from lumened instruments.\nMust be able to clean robotic instruments such as da Vinci SP and DV5 in accordance with Intuitive Surgical s Instructions for Use (IFU). This cleaning function must be a minimum of 15-minutes.\nMust be able to clean a minimum of 40 da Vinci Robotic Instruments in one cycle.\nMust have a minimum of 72 dedicated irrigation ports.\nMust have a minimum of 12 ports/tray.\nMust be able to process a minimum of 10 robotic or lumen instruments.\nMust be able to cleanse up to a minimum of 4 lumen/standard instrument trays simultaneously, split equally independently per operable basins.\nMust have a minimum of 30 pull-down sprayer faucet for external rinsing of instruments.\nMust have an automatic powered lid opening and load tray elevator.\nMust have slide and lock mechanism for loading of trays.\nMust have a minimum of 6-tray capacity.\nMust have ultraviolet germicidal system to remove and deactivate microorganisms such as bacteria, fungi, and viruses.\nMust be able to support a minimum of total 80-lb instrument weight capacity, a minimum of 40lbs each basin.\nElectrical voltage must be 208-volt wall receptacle.\nUnit dimension must not exceed 33-3/8 W x 49-11/16 D x 67-1/2 H at rest, open position due to limited staging/operating space.\nMust include a rotating and adjustable screen display to allow users of varying height to easily view pertinent operating information during use.\nMust have fully automatic wash, flush, internal wash, external wash, air purge cycles, and drain.\nMust have Tap, RO, DI water compatible.\nMust have an automatic lifts and slide-lock trays.\nMust have ultraviolet germicidal system.\nMust not have degassing for optimal cleaning process.\nMust come with seismic anchoring.\n\nSALIENT CHARACTERISTICS Compact Countertop Ultrasonic Cleaner 1100\n\nMust offer adjustable cycle time up to 10-minutes; allowing users to comply with different instrument manufacturer s IFU.\nMust be able to process both lumen and non-lumen instruments in the same cycle simultaneously.\nMust have a minimum of 12.5-lb total instrument weight capacity\nMust be equipped with 8 piezoelectric bonded transducers to ensure sensing heat level meets the minimum temperature to break bioburden in the RMD instruments.\nMust have adjustable irrigation allowing users to control water flow for multiple instrument types\nMust have a minimum of 12 dedicated irrigation ports for lumen instrument cleaning.\nMust works with or without irrigation.\nMust have graphical touchscreen display with programmable timer.\nMust have a Bi-fold lid allowing placement beneath overhead cabinets.\nMust have a minimum of 2 shelves for supplies\nMust have automatic fill, wash, and drain functions.\nMust have automatic degas\nMust be tap, reverse osmosis, and deionized water compatible.\nMust have a minimum of 5.75-gallon basin capacity.\nMust have 120-volt wall receptacle.\nMust not exceed overall dimension of 32-1/2 W x 18-3/4 D x 17-9/16 H (lid open) due to limited space.\nMust accept hospital trays without irrigation.\nMust come with seismic anchoring.\n\nMINIMUM SALIENT CHARACTERISTICS Single-Tank Floor-Mounted UC 2460\n\nMust have hands-free starting and stopping of cycle.\nMust have powered load tray elevator with safe lifting capacity of up to 35 lbs.\nMust have free moving lid that automatically closes and opens with tray elevator action; lid must not be fixed but moves freely and is automatically operated in conjunction with the tray elevator.\nMust be stainless steel construction of exterior panels and sonic cleaning chamber for durability, ease of cleaning, and resistance to corrosion.\nMust include a common operating control for start/stop functions, drain and system alarm accessible via the external back display panel due to the separation of clean and dirty sides of Sterile Processing. The start/stop function is needed on the back panel, which is on the dirty side. Any draining need to happen on the decontamination area and the employees need to be able to control those functions.\nProgramming buttons, controls for process time, detergent dispensing must be located within the unit to help safeguard unauthorized changes to the program parameters.\nMust have a minimum of 5 external back panel as a splash guard to prevent process water from getting onto the wall.\nMust have marine edges to keep process water from spilling onto the floor as trays are removed from the unit.\nMust include a hinged cover designed to minimize the overhead clearance required for chamber access.\nThe cover must fold or lay flat against the machine s surface to prevent processing water from splashing outside the unit.\nLid must be double pan construction with insulation between pans. Due to the strength/hazard of the detergents used to break down and clean any bioburden on the instrument trays, the equipment must have a safety mechanism to help contain the detergent and not easily breakdown the glass plan that separates the clean and dirty sides.\nMust have automatic detergent fill; allowing users to press start to press cycle so the system detects how much detergent is needed for the process.\nMust have a low liquid level sensor to assure the heaters are covered with water.\nMust have a high liquid level sensor provided to assure proper liquid level depth for ultrasonic cleaning.\nMust have built-in overflow protection to drain basin.\nMust have automatic cycle start and stop.\nMust have an audible cycle alarm to signal the start/end of a cycle\nMust have automatic cycle timers to allow specific instrument trays to complete a cycle.\nMust have a thermostat that automatically controls heater and maintains tank solution at pre-set temperature.\nMust have a controller that automatically dispenses pre-set amount of sonic detergent into the water as the tank fills.\nMust have low detergent indicator display.\nMust have automatic drain function.\nSafety door interlock to cut power when access door is opened, causing the elevator to lower, lid to close, and unit to drain\nDimensions must not exceed 33 1/2 L x 27 Â½ W x 41 H due to limited space.\nChamber overall dimension must be a minimum of 13 x 15 x 27 .\nMust be able to clean and disinfect with hospital grade disinfectants.\nMust meet electrical supply of 220 1-ph 50-60hz, 6.2 full load amps.\nMust include manual and motorized position locking capabilities.\nMust have a minimum of 62.5-Liter Capacity.\nMust come with Seismic anchoring.\n\nIMPLEMENTATION AND INSTALLATION\n\nInstallation and validation shall be included in the procurement cost and shall include but not limited to:\nAssembly of devices and validation\nAll materials required to assemble the ultrasonic shall be provided by the contractor\nThe contractor will deliver ultrasonic cleaning systems and accessories to:\n3350 La Jolla Village Dr, San Diego, CA 92161-0002, BLDG 1, Room B191K\nInstallation must occur during normal working hours: Monday through Friday 8:00am 3:00pm.\n\nTRAINING\n\nThe contractor shall provide onsite training for all MWV VAMC staff that requires training. Training shall be set up between SPS educator and contractor on a mutually agreed upon time and date.\n\nDELIVERY\n\nThe contractor shall deliver necessary equipment to the San Diego VA Medical Center facility as required in the quantities specified above.\nThe contractor must give VAMC staff 3 weeks notice of shipment and delivery of the ultrasonic and accessories.\nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box.\nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMC facilities.\nDelivery Address:\n3350 La Jolla Village Dr, San Diego, CA 92161-0002, BLDG 1, West Dock\n\nINSPECTION AND ACCEPTANCE\n\nThe contractor shall conduct a joint inspection with the COR upon delivery of equipment.\nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\n\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format.\nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted.\nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities.\nThe assembly and validation of the system must be performed by the technician who are either Original Equipment Manufacturer (OEM) certified or has been formally trained and approved by OEM.\nThe contractor is responsible for identifying any missing parts or components not included in the order for the ultrasonic systems to be successfully installed and validated to their full potential and full function listed under the Statement of Work.\n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to MWV clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the MWV clinical staff after delivery and installation.\n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings.\nThe contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor.\n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff.\nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement.\n\nWARRANTY\nAt a minimum the ultrasonic cleaning systems must include a 1-year warranty on all parts and labor at no cost to the Government.\nThe warranty shall begin upon completion of validation testing and approved by the COR.\nWarranty shall include on-site repairs and over-the-phone support.\nContractor shall provide routine maintenance service program during warranty period. Routine maintenance includes daily, weekly, and monthly maintenance.\nWarranty and routine maintenance shall include contractor s responsibility of draining and cleaning of basin, cleaning of the external surfaces, inspecting electrical connections, cleaning water level sensors, cleaning filter screens, checking and replacing drain screen, checking all plumbing connections, and checking peristaltic pump and tubing for cracks or leaks.\nAll repairs shall be performed by the OEM or contractors that have been certified and approved by the OEM to perform the repairs.\nThe warranty shall include all travel and shipping costs associated with any warranty repair.\n\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.\nIf your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SOW requirements. For instances where your company cannot meet the SOW requirement(s), please explain. For instances where your company can meet the SOW requirement(s), please show how your company meets/exceeds each requirement.\n(2) Please review the list of SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SOW?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution? What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.\n(15) Does your organization offer a leasing solution? Please elaborate.\n(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, June 20, 2025, by 10AM Pacific Local Time.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26225Q1021","place_of_performance":{"zip":"92161","city":{"name":"San Diego"},"state":{"name":"CA"},"street":"Department of Veterans Affairs VA San Diego Healthcare System","country":{"code":"USA","name":"UNITED STATES"},"street2":"Sterile Processing Service 3350 La Jolla Village Drive"},"product_service_code":"6515"}],"due_at":"2025-06-20T17:00:00Z","due_date":"2025-06-20","closes_at":"2025-06-20T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-12T16:05:29.692974Z","principal_notice_id":"2aa4aed7860d4af688e4008688bf9aa5","description":{"text":"THIS REQUEST FOR INFORMATION (RFI) /Â SOURCES SOUGHT NOTICE IS ISSUEDÂ SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought Notice / RFI only. The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA) is seeking sources capable of providing Ultrasonic Cleaning System in accordance with following Statement of Work.\n\nSTATEMENT OF WORK\n\nGENERAL\n\nThe Department of Veterans Affairs (VA), Network Contracting Office 22, requires Sterile Processing Equipment for the Sterile Processing Services (SPS) at the Jennifer Moreno VA Medical Center located in San Diego, California.\n\nBACKGROUND\n\nThe VA San Diego Healthcare System (VASDHCS) requires the procurement and installation of (2) large-capacity, floor-model ultrasonic cleaners, (1) compact tabletop ultrasonic cleaning system, and (1) single-tank floor-mounted ultrasonic cleaning system for SPS.\n\nVASDHCS requires a Contractor to provide the SPS equipment specified in this statement of work and coordinate efforts with SPS staff and contracting personnel to ensure equipment is installed and functional.\n\nThe Contractor shall provide all labor, materials, equipment, transportation, installation, and supervision necessary to satisfy the requirement.\n\nGENERAL REQUIREMENTS\n\nPLACE OF PERFORMANCE:\nVA San Diego Healthcare System\n3350 La Jolla Village Drive,\nSan Diego, CA 92161\nBldg 1, Sterile Processing Service Decon, Rm B191K\n\nDELIVERABLES\n\nThe Contractor shall provide the following:\n\nCLIN\nDescription\nQuantity\nUOM\n0001\nGetinge Triton 72 Floor Model Ultrasonic Cleaning System or equivalent Ultrasonic Cleaner with large capacity to reprocess complex surgical instruments trays\n2\nEA\n0002\nGetinge 1100 Ultrasonic Cleaning or equivalent Compact Tabletop Ultrasonic Cleaner\n1\nEA\n0003\nGetinge Ultrasonic Cleaner 2460C or equivalent Single-Tank Ultrasonic Cleaner\n1\nEA\n0004\nSeismic Anchoring\n4\nEA\n0005\nInstallation and Training\n1\nJB\n0006\nDe-installation of old total three equipment and dispose of two out of three equipment deinstalled.\n1\nJB\n\nNOTE: Potential offers must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are or equal , a description of the salient characteristics is outlined below. The FAR Clause 52.211-6 Brand Name or Equal applies to this acquisition. Offeror quotations must demonstrate meeting the salient physical, and functional characteristics included in this solicitation, otherwise, they will be considered non-responsive and not considered for award.\nNo remanufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM signed. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contain the signature of an authorized official for the manufacturer.\n\nSALIENT CHARACTERISTICS Large Capacity Ultrasonic Cleaner Triton 72\n\nThe Sterile Processing Service requires ultrasonic cleaning systems for cleaning and disinfecting of instruments to clean and remove debris from instrumentation.\n\nMust have a minimum of 30-gallon capacity per basin.\nMust have a minimum of 2 basins per unit.\nMust have a minimum of 8 to 13 minutes ultrasonic cleaning cycles for laparoscopic and non-lumen instruments.\nMust have Ultrasonic cavitation cycle designed for removal of blood and debris from lumened instruments.\nMust be able to clean robotic instruments such as da Vinci SP and DV5 in accordance with Intuitive Surgical s Instructions for Use (IFU). This cleaning function must be a minimum of 15-minutes.\nMust be able to clean a minimum of 40 da Vinci Robotic Instruments in one cycle.\nMust have a minimum of 72 dedicated irrigation ports.\nMust have a minimum of 12 ports/tray.\nMust be able to process a minimum of 10 robotic or lumen instruments.\nMust be able to cleanse up to a minimum of 4 lumen/standard instrument trays simultaneously, split equally independently per operable basins.\nMust have a minimum of 30 pull-down sprayer faucet for external rinsing of instruments.\nMust have an automatic powered lid opening and load tray elevator.\nMust have slide and lock mechanism for loading of trays.\nMust have a minimum of 6-tray capacity.\nMust have ultraviolet germicidal system to remove and deactivate microorganisms such as bacteria, fungi, and viruses.\nMust be able to support a minimum of total 80-lb instrument weight capacity, a minimum of 40lbs each basin.\nElectrical voltage must be 208-volt wall receptacle.\nUnit dimension must not exceed 33-3/8 W x 49-11/16 D x 67-1/2 H at rest, open position due to limited staging/operating space.\nMust include a rotating and adjustable screen display to allow users of varying height to easily view pertinent operating information during use.\nMust have fully automatic wash, flush, internal wash, external wash, air purge cycles, and drain.\nMust have Tap, RO, DI water compatible.\nMust have an automatic lifts and slide-lock trays.\nMust have ultraviolet germicidal system.\nMust not have degassing for optimal cleaning process.\nMust come with seismic anchoring.\n\nSALIENT CHARACTERISTICS Compact Countertop Ultrasonic Cleaner 1100\n\nMust offer adjustable cycle time up to 10-minutes; allowing users to comply with different instrument manufacturer s IFU.\nMust be able to process both lumen and non-lumen instruments in the same cycle simultaneously.\nMust have a minimum of 12.5-lb total instrument weight capacity\nMust be equipped with 8 piezoelectric bonded transducers to ensure sensing heat level meets the minimum temperature to break bioburden in the RMD instruments.\nMust have adjustable irrigation allowing users to control water flow for multiple instrument types\nMust have a minimum of 12 dedicated irrigation ports for lumen instrument cleaning.\nMust works with or without irrigation.\nMust have graphical touchscreen display with programmable timer.\nMust have a Bi-fold lid allowing placement beneath overhead cabinets.\nMust have a minimum of 2 shelves for supplies\nMust have automatic fill, wash, and drain functions.\nMust have automatic degas\nMust be tap, reverse osmosis, and deionized water compatible.\nMust have a minimum of 5.75-gallon basin capacity.\nMust have 120-volt wall receptacle.\nMust not exceed overall dimension of 32-1/2 W x 18-3/4 D x 17-9/16 H (lid open) due to limited space.\nMust accept hospital trays without irrigation.\nMust come with seismic anchoring.\n\nMINIMUM SALIENT CHARACTERISTICS Single-Tank Floor-Mounted UC 2460\n\nMust have hands-free starting and stopping of cycle.\nMust have powered load tray elevator with safe lifting capacity of up to 35 lbs.\nMust have free moving lid that automatically closes and opens with tray elevator action; lid must not be fixed but moves freely and is automatically operated in conjunction with the tray elevator.\nMust be stainless steel construction of exterior panels and sonic cleaning chamber for durability, ease of cleaning, and resistance to corrosion.\nMust include a common operating control for start/stop functions, drain and system alarm accessible via the external back display panel due to the separation of clean and dirty sides of Sterile Processing. The start/stop function is needed on the back panel, which is on the dirty side. Any draining need to happen on the decontamination area and the employees need to be able to control those functions.\nProgramming buttons, controls for process time, detergent dispensing must be located within the unit to help safeguard unauthorized changes to the program parameters.\nMust have a minimum of 5 external back panel as a splash guard to prevent process water from getting onto the wall.\nMust have marine edges to keep process water from spilling onto the floor as trays are removed from the unit.\nMust include a hinged cover designed to minimize the overhead clearance required for chamber access.\nThe cover must fold or lay flat against the machine s surface to prevent processing water from splashing outside the unit.\nLid must be double pan construction with insulation between pans. Due to the strength/hazard of the detergents used to break down and clean any bioburden on the instrument trays, the equipment must have a safety mechanism to help contain the detergent and not easily breakdown the glass plan that separates the clean and dirty sides.\nMust have automatic detergent fill; allowing users to press start to press cycle so the system detects how much detergent is needed for the process.\nMust have a low liquid level sensor to assure the heaters are covered with water.\nMust have a high liquid level sensor provided to assure proper liquid level depth for ultrasonic cleaning.\nMust have built-in overflow protection to drain basin.\nMust have automatic cycle start and stop.\nMust have an audible cycle alarm to signal the start/end of a cycle\nMust have automatic cycle timers to allow specific instrument trays to complete a cycle.\nMust have a thermostat that automatically controls heater and maintains tank solution at pre-set temperature.\nMust have a controller that automatically dispenses pre-set amount of sonic detergent into the water as the tank fills.\nMust have low detergent indicator display.\nMust have automatic drain function.\nSafety door interlock to cut power when access door is opened, causing the elevator to lower, lid to close, and unit to drain\nDimensions must not exceed 33 1/2 L x 27 Â½ W x 41 H due to limited space.\nChamber overall dimension must be a minimum of 13 x 15 x 27 .\nMust be able to clean and disinfect with hospital grade disinfectants.\nMust meet electrical supply of 220 1-ph 50-60hz, 6.2 full load amps.\nMust include manual and motorized position locking capabilities.\nMust have a minimum of 62.5-Liter Capacity.\nMust come with Seismic anchoring.\n\nIMPLEMENTATION AND INSTALLATION\n\nInstallation and validation shall be included in the procurement cost and shall include but not limited to:\nAssembly of devices and validation\nAll materials required to assemble the ultrasonic shall be provided by the contractor\nThe contractor will deliver ultrasonic cleaning systems and accessories to:\n3350 La Jolla Village Dr, San Diego, CA 92161-0002, BLDG 1, Room B191K\nInstallation must occur during normal working hours: Monday through Friday 8:00am 3:00pm.\n\nTRAINING\n\nThe contractor shall provide onsite training for all MWV VAMC staff that requires training. Training shall be set up between SPS educator and contractor on a mutually agreed upon time and date.\n\nDELIVERY\n\nThe contractor shall deliver necessary equipment to the San Diego VA Medical Center facility as required in the quantities specified above.\nThe contractor must give VAMC staff 3 weeks notice of shipment and delivery of the ultrasonic and accessories.\nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box.\nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMC facilities.\nDelivery Address:\n3350 La Jolla Village Dr, San Diego, CA 92161-0002, BLDG 1, West Dock\n\nINSPECTION AND ACCEPTANCE\n\nThe contractor shall conduct a joint inspection with the COR upon delivery of equipment.\nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\n\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format.\nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted.\nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities.\nThe assembly and validation of the system must be performed by the technician who are either Original Equipment Manufacturer (OEM) certified or has been formally trained and approved by OEM.\nThe contractor is responsible for identifying any missing parts or components not included in the order for the ultrasonic systems to be successfully installed and validated to their full potential and full function listed under the Statement of Work.\n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to MWV clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the MWV clinical staff after delivery and installation.\n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings.\nThe contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor.\n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff.\nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement.\n\nWARRANTY\nAt a minimum the ultrasonic cleaning systems must include a 1-year warranty on all parts and labor at no cost to the Government.\nThe warranty shall begin upon completion of validation testing and approved by the COR.\nWarranty shall include on-site repairs and over-the-phone support.\nContractor shall provide routine maintenance service program during warranty period. Routine maintenance includes daily, weekly, and monthly maintenance.\nWarranty and routine maintenance shall include contractor s responsibility of draining and cleaning of basin, cleaning of the external surfaces, inspecting electrical connections, cleaning water level sensors, cleaning filter screens, checking and replacing drain screen, checking all plumbing connections, and checking peristaltic pump and tubing for cracks or leaks.\nAll repairs shall be performed by the OEM or contractors that have been certified and approved by the OEM to perform the repairs.\nThe warranty shall include all travel and shipping costs associated with any warranty repair.\n\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required.\nIf your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SOW requirements. For instances where your company cannot meet the SOW requirement(s), please explain. For instances where your company can meet the SOW requirement(s), please show how your company meets/exceeds each requirement.\n(2) Please review the list of SOW requirements and provide any additional feedback or suggestions. If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SOW?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components? Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution? What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance? Please specify what FDA clearance(s) have been obtained.\n(15) Does your organization offer a leasing solution? Please elaborate.\n(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, June 20, 2025, by 10AM Pacific Local Time.\nAll responses to this Sources Sought/RFI will be used for planning purposes only. Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","html":"THIS REQUEST FOR INFORMATION (RFI) /Â SOURCES SOUGHT NOTICE IS ISSUEDÂ  SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.\nSUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought Notice / RFI only.  The purpose of this Sources Sought Notice / RFI is to gain information about potential qualified sources and their size classification relative to NAICS 339113 (size standard of 800 Employees). Responses to this Sources Sought Notice / RFI will be used by the Government to make appropriate acquisition decisions.  After review of the responses to this Sources Sought Notice / RFI, further RFIs and/or a solicitation or other announcements may be published.  \nThe Department of Veterans Affairs (VA) is seeking sources capable of providing Ultrasonic Cleaning System in accordance with following Statement of Work.\n\nSTATEMENT OF WORK\n\nGENERAL\n\nThe Department of Veterans Affairs (VA), Network Contracting Office 22, requires Sterile Processing Equipment for the Sterile Processing Services (SPS) at the Jennifer Moreno VA Medical Center located in San Diego, California.  \n\nBACKGROUND\n\nThe VA San Diego Healthcare System (VASDHCS) requires the procurement and installation of (2) large-capacity, floor-model ultrasonic cleaners, (1) compact tabletop ultrasonic cleaning system, and (1) single-tank floor-mounted ultrasonic cleaning system for SPS.\n\nVASDHCS requires a Contractor to provide the SPS equipment specified in this statement of work and coordinate efforts with SPS staff and contracting personnel to ensure equipment is installed and functional.\n\nThe Contractor shall provide all labor, materials, equipment, transportation, installation, and supervision necessary to satisfy the requirement.\n\nGENERAL REQUIREMENTS\n\nPLACE OF PERFORMANCE:\nVA San Diego Healthcare System\n3350 La Jolla Village Drive,\nSan Diego, CA 92161\nBldg 1, Sterile Processing Service Decon, Rm B191K\n\nDELIVERABLES\n\nThe Contractor shall provide the following:\n\nCLIN\nDescription\nQuantity\nUOM\n0001\nGetinge Triton 72 Floor Model Ultrasonic Cleaning System or equivalent Ultrasonic Cleaner with large capacity to reprocess complex surgical instruments trays\n2\nEA\n0002\nGetinge 1100 Ultrasonic Cleaning or equivalent Compact Tabletop Ultrasonic Cleaner\n1\nEA\n0003\nGetinge Ultrasonic Cleaner 2460C or equivalent Single-Tank Ultrasonic Cleaner\n1\nEA\n0004\nSeismic Anchoring\n4\nEA\n0005\nInstallation and Training\n1\nJB\n0006\nDe-installation of old total three equipment and dispose of two out of three equipment deinstalled.\n1\nJB\n\nNOTE: Potential offers must be aware that the items being acquired are procured as Brand Name or Equal. For those items that are  or equal , a description of the salient characteristics is outlined below. The FAR Clause 52.211-6 Brand Name or Equal applies to this acquisition. Offeror quotations must demonstrate meeting the salient physical, and functional characteristics included in this solicitation, otherwise, they will be considered non-responsive and not considered for award.\nNo remanufactures or gray market items will be acceptable. Vendor shall be an Original Equipment Manufacturer (OEM), authorized dealer, authorized distributor or authorized reseller verified by an authorization letter or other documents from the OEM signed. The letter must either state specific product(s) quoted or that the quoter is an authorized distributor for all the manufacturer s products. This letter must be on the manufacturer s letterhead and contain the signature of an authorized official for the manufacturer.\n\nSALIENT CHARACTERISTICS   Large Capacity Ultrasonic Cleaner Triton 72\n\nThe Sterile Processing Service requires ultrasonic cleaning systems for cleaning and disinfecting of instruments to clean and remove debris from instrumentation.\n\nMust have a minimum of 30-gallon capacity per basin.\nMust have a minimum of 2 basins per unit.\nMust have a minimum of 8 to 13 minutes ultrasonic cleaning cycles for laparoscopic and non-lumen instruments.\nMust have Ultrasonic cavitation cycle designed for removal of blood and debris from lumened instruments.\nMust be able to clean robotic instruments such as da Vinci SP and DV5 in accordance with Intuitive Surgical  s Instructions for Use (IFU). This cleaning function must be a minimum of 15-minutes.\nMust be able to clean a minimum of 40 da Vinci Robotic Instruments in one cycle.\nMust have a minimum of 72 dedicated irrigation ports.\nMust have a minimum of 12 ports/tray.\nMust be able to process a minimum of 10 robotic or lumen instruments.\nMust be able to cleanse up to a minimum of 4 lumen/standard instrument trays simultaneously, split equally independently per operable basins.\nMust have a minimum of 30  pull-down sprayer faucet for external rinsing of instruments.\nMust have an automatic powered lid opening and load tray elevator.\nMust have slide and lock mechanism for loading of trays.\nMust have a minimum of 6-tray capacity.\nMust have ultraviolet germicidal system to remove and deactivate microorganisms such as bacteria, fungi, and viruses.\nMust be able to support a minimum of total 80-lb instrument weight capacity, a minimum of 40lbs each basin.\nElectrical voltage must be 208-volt wall receptacle.\nUnit dimension must not exceed 33-3/8 W x 49-11/16 D x 67-1/2 H at rest, open position due to limited staging/operating space.\nMust include a rotating and adjustable screen display to allow users of varying height to easily view pertinent operating information during use.\nMust have fully automatic wash, flush, internal wash, external wash, air purge cycles, and drain.\nMust have Tap, RO, DI water compatible.\nMust have an automatic lifts and slide-lock trays.\nMust have ultraviolet germicidal system.\nMust not have degassing for optimal cleaning process.\nMust come with seismic anchoring.\n\nSALIENT CHARACTERISTICS   Compact Countertop Ultrasonic Cleaner 1100\n\nMust offer adjustable cycle time up to 10-minutes; allowing users to comply with different instrument manufacturer s IFU.\nMust be able to process both lumen and non-lumen instruments in the same cycle simultaneously.\nMust have a minimum of 12.5-lb total instrument weight capacity\nMust be equipped with 8 piezoelectric bonded transducers to ensure sensing heat level meets the minimum temperature to break bioburden in the RMD instruments.  \nMust have adjustable irrigation allowing users to control water flow for multiple instrument types\nMust have a minimum of 12 dedicated irrigation ports for lumen instrument cleaning.\nMust works with or without irrigation.\nMust have graphical touchscreen display with programmable timer.\nMust have a Bi-fold lid allowing placement beneath overhead cabinets.\nMust have a minimum of 2 shelves for supplies\nMust have automatic fill, wash, and drain functions.\nMust have automatic degas\nMust be tap, reverse osmosis, and deionized water compatible.\nMust have a minimum of 5.75-gallon basin capacity.\nMust have 120-volt wall receptacle.\nMust not exceed overall dimension of 32-1/2 W x 18-3/4 D x 17-9/16 H (lid open) due to limited space.\nMust accept hospital trays without irrigation.\nMust come with seismic anchoring.\n\nMINIMUM SALIENT CHARACTERISTICS   Single-Tank Floor-Mounted UC 2460\n\nMust have hands-free starting and stopping of cycle.\nMust have powered load tray elevator with safe lifting capacity of up to 35 lbs.\nMust have free moving lid that automatically closes and opens with tray elevator action; lid must not be fixed but moves freely and is automatically operated in conjunction with the tray elevator.\nMust be stainless steel construction of exterior panels and sonic cleaning chamber for durability, ease of cleaning, and resistance to corrosion.\nMust include a common operating control for start/stop functions, drain and system alarm accessible via the external back display panel due to the separation of clean and dirty sides of Sterile Processing.  The start/stop function is needed on the back panel, which is on the dirty side.  Any draining need to happen on the decontamination area and the employees need to be able to control those functions. \nProgramming buttons, controls for process time, detergent dispensing must be located within the unit to help safeguard unauthorized changes to the program parameters.\nMust have a minimum of 5  external back panel as a splash guard to prevent process water from getting onto the wall.\nMust have marine edges to keep process water from spilling onto the floor as trays are removed from the unit.\nMust include a hinged cover designed to minimize the overhead clearance required for chamber access.\nThe cover must fold or lay flat against the machine s surface to prevent processing water from splashing outside the unit.\nLid must be double pan construction with insulation between pans. Due to the strength/hazard of the detergents used to break down and clean any bioburden on the instrument trays, the equipment must have a safety mechanism to help contain the detergent and not easily breakdown the glass plan that separates the clean and dirty sides.\nMust have automatic detergent fill; allowing users to press  start  to press cycle so the system detects how much detergent is needed for the process.\nMust have a low liquid level sensor to assure the heaters are covered with water.\nMust have a high liquid level sensor provided to assure proper liquid level depth for ultrasonic cleaning.\nMust have built-in overflow protection to drain basin.\nMust have automatic cycle start and stop.\nMust have an audible cycle alarm to signal the start/end of a cycle\nMust have automatic cycle timers to allow specific instrument trays to complete a cycle.\nMust have a thermostat that automatically controls heater and maintains tank solution at pre-set temperature.\nMust have a controller that automatically dispenses pre-set amount of sonic detergent into the water as the tank fills.\nMust have low detergent indicator display.\nMust have automatic drain function.\nSafety door interlock to cut power when access door is opened, causing the elevator to lower, lid to close, and unit to drain\nDimensions must not exceed 33 1/2   L x 27 Â½  W x 41 H due to limited space.\nChamber overall dimension must be a minimum of 13  x 15  x 27 .\nMust be able to clean and disinfect with hospital grade disinfectants.\nMust meet electrical supply of 220 1-ph 50-60hz, 6.2 full load amps.\nMust include manual and motorized position locking capabilities.\nMust have a minimum of 62.5-Liter Capacity.\nMust come with Seismic anchoring.\n\n\nIMPLEMENTATION AND INSTALLATION \n\nInstallation and validation shall be included in the procurement cost and shall include but not limited to: \nAssembly of devices and validation\nAll materials required to assemble the ultrasonic shall be provided by the contractor\nThe contractor will deliver ultrasonic cleaning systems and accessories to: \n3350 La Jolla Village Dr, San Diego, CA  92161-0002, BLDG 1, Room B191K\nInstallation must occur during normal working hours: Monday through Friday 8:00am   3:00pm.\n\nTRAINING\n\nThe contractor shall provide onsite training for all MWV VAMC staff that requires training. Training shall be set up between SPS educator and contractor on a mutually agreed upon time and date.\n\nDELIVERY\n\nThe contractor shall deliver necessary equipment to the San Diego VA Medical Center facility as required in the quantities specified above. \nThe contractor must give VAMC staff 3 weeks  notice of shipment and delivery of the ultrasonic and accessories.  \nThe contractor shall coordinate all deliveries, installation, and parking arrangements with the COR.\nDelivered materials will arrive in manufacturer s original sealed containers with the associated purchase order number listed on the outside of the box. \nThe contractor shall conduct a joint inspection with the COR upon delivery of the equipment and shall provide the COR a list of missing or damaged items found upon inspection.\nThe contractor shall remove all related shipping debris and packing from the VAMC facilities.  \nDelivery Address:\n3350 La Jolla Village Dr, San Diego, CA  92161-0002, BLDG 1, West Dock\n\n\nINSPECTION AND ACCEPTANCE\n\nThe contractor shall conduct a joint inspection with the COR upon delivery of equipment. \nThe contractor shall provide the VA COR a list of missing and /or damaged items found upon inspection and have those items replaced at no cost to the Government.\nThe COR shall ensure all work is completed satisfactorily prior to acceptance. Disputes shall be resolved by the VA Contracting Officer.\n\nDELIVERABLES\n\nOperation and Maintenance Manuals\nDeliver compilation of all manufacturers recommended maintenance schedules and operation materials packaged upon delivery. Manuals shall be made available in an electronic format.\nThe contractor shall deliver and install the system with all specified salient characteristics. Only new equipment will be accepted.\nThe contractor shall provide shipping, transport, installation, and all equipment necessary to meet the requirements and capabilities.\nThe assembly and validation of the system must be performed by the technician who are either Original Equipment Manufacturer (OEM) certified or has been formally trained and approved by OEM.\nThe contractor is responsible for identifying any missing parts or components not included in the order for the ultrasonic systems to be successfully installed and validated to their full potential and full function listed under the Statement of Work.\n\nOPERATOR TRAINING\nOnsite education and training by a vendor service trained representative will be provided to MWV clinical staff, facilities and engineering staff, and the biomedical engineering staff. The scheduling of operator training shall be coordinated with the MWV clinical staff after delivery and installation. \n\nPROTECTION OF PROPERTY\nThe contractor shall protect all items from damage. The contractor shall take precaution against damage to the building(s), grounds and furnishings. \nThe contractor shall repair or replace any items related to building(s) or grounds damaged accidentally or on purpose due to actions by the Contractor. \n\nSECURITY REQUIREMENTS\nThe contractor must have a photo ID available when performing work at the VA Medical Center and be willing to present it to VA staff. \nThe contractor is responsible for providing any personal protective equipment (PPE) that is deemed necessary to complete tasks stated in this requirement. \n\nWARRANTY\nAt a minimum the ultrasonic cleaning systems must include a 1-year warranty on all parts and labor at no cost to the Government. \nThe warranty shall begin upon completion of validation testing and approved by the COR.\nWarranty shall include on-site repairs and over-the-phone support. \nContractor shall provide routine maintenance service program during warranty period. Routine maintenance includes daily, weekly, and monthly maintenance. \nWarranty and routine maintenance shall include contractor s responsibility of draining and cleaning of basin, cleaning of the external surfaces, inspecting electrical connections, cleaning water level sensors, cleaning filter screens, checking and replacing drain screen, checking all plumbing connections, and checking peristaltic pump and tubing for cracks or leaks.\nAll repairs shall be performed by the OEM or contractors that have been certified and approved by the OEM to perform the repairs. \nThe warranty shall include all travel and shipping costs associated with any warranty repair. \n\n\n\nThe list of DRAFT characteristics is intended to be descriptive, not restrictive, of the supplies/services that are required. \nIf your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of SOW requirements.  For instances where your company cannot meet the SOW requirement(s), please explain.  For instances where your company can meet the SOW requirement(s), please show how your company meets/exceeds each requirement.  \n(2) Please review the list of SOW requirements and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of SOW?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(11) Please indicate whether your product conforms to the requirements of the Buy American Act?\n(12) What is your lead time to deliver a single unit with all components?  Is there scale in lead time with greater quantities? Please elaborate.\n(13) What is estimated life span of your solution?  What support/services does that entail?\n(14) Does your proposed equipment have FDA clearance?  Please specify what FDA clearance(s) have been obtained.\n(15) Does your organization offer a leasing solution?  Please elaborate.\n(16) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(17) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(18) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(19) Please provide your SAM.gov Unique Entity ID/Cage Code number.\nResponses to this notice shall be submitted via email to Hestia.Sim@va.gov. Telephone responses will not be accepted.  Responses must be received no later than Friday, June 20, 2025, by 10AM Pacific Local Time.  \nAll responses to this Sources Sought/RFI will be used for planning purposes only.  Responses to this Sources Sought Notice / RFI are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.  If further RFIs and/or a solicitation or other announcement is issued as a result of the information provided from this RFI, all interested parties must respond to the specific posting separately IAW the specifications of that announcement.","origin":"detail"},"contacts":[{"name":"Hestia Sim","role":"primary","email":"Hestia.Sim@va.gov","title":"Contract Specialist"}],"place_of_performance":{"zip":"92161","city":{"name":"San Diego"},"state":{"name":"CA"},"street":"Department of Veterans Affairs VA San Diego Healthcare System","country":{"code":"USA","name":"UNITED STATES"},"street2":"Sterile Processing Service 3350 La Jolla Village Drive"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"b8a23cdff9a44b30960a8f4e6355193a","name":"36C26225Q1021.docx","kind":"file","mime_type":".docx","size_bytes":38774,"posted_at":"2025-06-12T19:13:13.677Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b8a23cdff9a44b30960a8f4e6355193a/download","mirrored":false}],"awards":[],"related":[{"key":"36C26227Q0085","latest_notice_id":"cdde3a94bda84b199f9d3db72af657a6","title":"S215--SDVOSB Furniture Installation Labor Storage - Base Plus Four Option Years | POP: (12/31/2026 - 12/30/2031) |","solicitation_number":"36C26227Q0085","notice_type":"o","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-23","notices":4,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"493190","psc":"S215","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C26227Q0079","latest_notice_id":"00646e7746494ab38ce53bbe9f7e0f59","title":"W065--RFQ | SBAR APPROVED | BED RENTAL WD WD EXEMPT","solicitation_number":"36C26227Q0079","notice_type":"k","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-26T20:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"532490","psc":"W065","set_aside":"SDVOSBC","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0139","latest_notice_id":"156fef93406e495486eb1d4e805bb675","title":"6515--PYXIS IV PREP","solicitation_number":"36C26227Q0139","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541519","psc":"6515","set_aside":"SDVOSBC","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26227Q0146","latest_notice_id":"e2fc7d7b106d4b448a5b57cba568ddb4","title":"J041--KITCHEN HOOD PMIR - Base +4 ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0146","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"561790","psc":"J041","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T08:15:06.508374Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"}],"similar_open":[{"key":"N0010427QXA15","latest_notice_id":"92eed9450f9c41eaa50e0b0c2334c9d8","title":"DISK, FILTER","solicitation_number":"N0010427QXA15","notice_type":"o","first_type":"o","first_posted":"2026-11-13","last_posted":"2026-11-18","notices":2,"due_at":"2026-12-14T22:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":"CA","county":"06087","county_name":"Santa Cruz County","city":"0618086","city_name":"Davenport","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open_total":20,"indexable":false}