{"canonical":"https://sealedbidder.com/opportunities/36c26225q0491","key":"36C26225Q0491","url":"https://sealedbidder.com/opportunities/36c26225q0491","title":"6515--600-25-1-441-0025 Puritan Bennett 980 Ventilator","solicitation_number":"36C26225Q0491","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-19T00:00:00Z","first_posted":"2025-02-12","last_posted":"2025-02-12","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"339112","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"cb05d9d8e1f2422e9daa9736b7618ecc","title":"6515--600-25-1-441-0025 Puritan Bennett 980 Ventilator","solicitation_number":"36C26225Q0491","notice_type":"r","base_type":"r","posted":"2025-02-12","posted_at":"2025-02-13T01:11:42.462Z","due_at":"2025-02-19T00:00:00Z","due_date":"2025-02-18","cancelled":false,"archived":true,"archive_date":"2025-03-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cb05d9d8e1f2422e9daa9736b7618ecc/view","enriched":true,"history":[{"index":3,"title":"6515--600-25-1-441-0025 Puritan Bennett 980 Ventilator","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-13T01:11:42.462Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"cb05d9d8e1f2422e9daa9736b7618ecc","solicitation_number":"36C26225Q0491"}]}],"latest_notice_id":"cb05d9d8e1f2422e9daa9736b7618ecc","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-12","posted_at":"2025-02-13T01:11:42.462Z","created_at":"2025-02-13T01:11:19.740Z","modified_at":"2025-03-21T03:55:44.754Z","response_deadline":{"raw":"2025-02-18T16:00:00-08:00","utc":"2025-02-19T00:00:00Z","date":"2025-02-18","time":"16:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cb05d9d8e1f2422e9daa9736b7618ecc/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--600-25-1-441-0025 Puritan Bennett 980 Ventilator","agency":{"office":{"code":"36C262","name":"262-NETWORK CONTRACT OFFICE 22 (36C262)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"organization_id":"100173469","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-20","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--600-25-1-441-0025 Puritan Bennett 980 Ventilator","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-13T01:11:42.462Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"cb05d9d8e1f2422e9daa9736b7618ecc","solicitation_number":"36C26225Q0491"}],"contacts":[{"name":"Emiljan Golemi","role":"primary","email":"emiljan.golemi@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"cb05d9d8e1f2422e9daa9736b7618ecc","lineage_id":"cb05d9d8e1f2422e9daa9736b7618ecc","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T12:25:24.661133787Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"26e19ad986c9adcbd314eb5806a63bf4e8da591557c7ab63b440352269c6d749","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T12:25:24.661133787Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought/RFI only.  The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this RFI/Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI/Sources Sought Notice, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office is seeking sources capable of providing Ventilator for the VA Long Beach Healthcare System and that can address the draft salient characteristics described below.  \nBrandname Information:\nManufacturer & Part Number(s): Medtronic, 98OS1ENDIUUS      \nType: PB980 PED TO ADULT - STANDARD BASE SHIPS WITH 1 PED/ADULT EXHALATION FILTER, 1 EVQ, 1 EVQ SEALS KIT, FLEX ARM, GOLD STANDARD CIRCUIT, OP MAN ON CD, POWER CORD AND SOFTWARE OPTIONS (PAV+, LEAK SYNC, BILEVEL 2.0, VV+, RESPIRATORY MECHANICS, TRENDING, TUBE COMPENSATION) AND 1 YEAR WARRANTY.\nEqual to product name: Ventilator \n\nManufacturer & Part Number(s): Medtronic, 10086042\nType: PROMO QS980BAT1-ZMPC- RECHARGEABLE LI-LON BATTERY - EACH VENTILATOR REQUIRES AT LEAST ONE BATTERY IN ORDER TO OPERATE.\nEqual to product name: RECHARGEABLE LI-LON BATTERY\n\nManufacturer & Part Number(s): Medtronic, SRVQ1-PB980AI \nType: PB980 PREMIUM SERVICE AGREEMENT\n\nEqual to product name: SERVICE AGREEMENT\n\nManufacturer & Part Number(s): Medtronic, 10086050\nType: 980 CYLINDER MOUNT X1\nEqual to product name: CYLINDER MOUNT\n\nManufacturer & Part Number(s): Medtronic, 10086049\nType: 980 HUMIDIFIER BRACKET X1 \nEqual to product name: HUMIDIFIER BRACKET\n\nManufacturer & Part Number(s): Medtronic, 10114989\nType: 980 DC COMP UPGRADE KIT\nEqual to product name: DC COMP KIT\n\nSalient Characteristics: \n\nMust have ventilation modes and therapies for:\n\nVolume and flow control \nVolume targeted, adaptive pressure control\nIntelligent ventilation\nNoninvasive ventilation \nHigh flow\nflow sensor measures flow, pressure, and tidal volume\n\nMust have advanced monitoring for:\n\nVisualization of lung mechanics (Dynamic Lung) \nVisualization of the patient s ventilator dependence \nEsophageal pressure measurement \nCapnography \nSpO2 monitoring\n\nMust have safety features for:\n\nVentilated patients in the event of system failures.\nDelivering ventilatory support as close to the preset settings\nMust have stand-by mode which pauses ventilation and preserves settings when the patient is disconnected.\nMust auto-detects patient upon reconnection\nMust automatically resumes ventilation without the need to push additional buttons\nMust have additional screen located on the breath delivery unit (BDU) and provides a check of ventilator operation\nMust have custom filters to prevent infection and contamination\nMust have custom filters features of 99.97% filtration efficiency and meets CDC requirement for N100 filtration equivalency\nMust house up to two batteries\nMust have batteries that can be changed/swapped out without having to power down and interrupt patient ventilation\n\nOther ventilation must have features:\n\nMust have recruitability assessment and lung recruitment (P/V Tool Pro) \nMust have patient ventilator synchronization (IntelliSync+) \nMust have CPR ventilation \nMust have Hamilton Connect Module \nMust have Hamilton Connect App\nMust have configurable touch screen to offer access to five graph and loop layout options\nMust be able to pause the screen and review the last 60 seconds of patient data\nMust provide a unique ventilator assurance feature, which, in the event of certain system failures, will continue to deliver ventilatory support as close to the preset settings \nMust have an integrated expiratory filtration system.\nMust be able to synchronize tools to help clinicians set the ventilator to adapt to their patients' unique needs\nMust have digital communication board which provides multiple USB ports for connections to external drives\nMust have HDMI output port\n\nThe list of draft characteristics is intended to be descriptive, not restrictive, of the supplies and/or services that are required. \nIf your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below.  For instances where your company cannot meet the draft salient characteristic(s), please explain.  For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.  \n(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified. \n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item.\n(12) What is your lead time to deliver all items?\n(13) Does your proposed equipment have FDA clearance (if needed)?  Please specify what FDA clearance(s) have been obtained.\n(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(17) Please provide your SAM.gov Unique Entity ID number.\nResponses to this notice shall be submitted via email to Emiljan.Golemi@va.gov. Telephone responses will not be accepted. Responses must be received no later than Tuesday, February 18, 2025, by 4:00 PM PST.  \nAll responses to this RFI/Sources Sought will be used for planning purposes only.  Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.  If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.","text":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought/RFI only. The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this RFI/Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI/Sources Sought Notice, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office is seeking sources capable of providing Ventilator for the VA Long Beach Healthcare System and that can address the draft salient characteristics described below.\nBrandname Information:\nManufacturer & Part Number(s): Medtronic, 98OS1ENDIUUS\nType: PB980 PED TO ADULT - STANDARD BASE SHIPS WITH 1 PED/ADULT EXHALATION FILTER, 1 EVQ, 1 EVQ SEALS KIT, FLEX ARM, GOLD STANDARD CIRCUIT, OP MAN ON CD, POWER CORD AND SOFTWARE OPTIONS (PAV+, LEAK SYNC, BILEVEL 2.0, VV+, RESPIRATORY MECHANICS, TRENDING, TUBE COMPENSATION) AND 1 YEAR WARRANTY.\nEqual to product name: Ventilator\n\nManufacturer & Part Number(s): Medtronic, 10086042\nType: PROMO QS980BAT1-ZMPC- RECHARGEABLE LI-LON BATTERY - EACH VENTILATOR REQUIRES AT LEAST ONE BATTERY IN ORDER TO OPERATE.\nEqual to product name: RECHARGEABLE LI-LON BATTERY\n\nManufacturer & Part Number(s): Medtronic, SRVQ1-PB980AI\nType: PB980 PREMIUM SERVICE AGREEMENT\n\nEqual to product name: SERVICE AGREEMENT\n\nManufacturer & Part Number(s): Medtronic, 10086050\nType: 980 CYLINDER MOUNT X1\nEqual to product name: CYLINDER MOUNT\n\nManufacturer & Part Number(s): Medtronic, 10086049\nType: 980 HUMIDIFIER BRACKET X1\nEqual to product name: HUMIDIFIER BRACKET\n\nManufacturer & Part Number(s): Medtronic, 10114989\nType: 980 DC COMP UPGRADE KIT\nEqual to product name: DC COMP KIT\n\nSalient Characteristics:\n\nMust have ventilation modes and therapies for:\n\nVolume and flow control\nVolume targeted, adaptive pressure control\nIntelligent ventilation\nNoninvasive ventilation\nHigh flow\nflow sensor measures flow, pressure, and tidal volume\n\nMust have advanced monitoring for:\n\nVisualization of lung mechanics (Dynamic Lung)\nVisualization of the patient s ventilator dependence\nEsophageal pressure measurement\nCapnography\nSpO2 monitoring\n\nMust have safety features for:\n\nVentilated patients in the event of system failures.\nDelivering ventilatory support as close to the preset settings\nMust have stand-by mode which pauses ventilation and preserves settings when the patient is disconnected.\nMust auto-detects patient upon reconnection\nMust automatically resumes ventilation without the need to push additional buttons\nMust have additional screen located on the breath delivery unit (BDU) and provides a check of ventilator operation\nMust have custom filters to prevent infection and contamination\nMust have custom filters features of 99.97% filtration efficiency and meets CDC requirement for N100 filtration equivalency\nMust house up to two batteries\nMust have batteries that can be changed/swapped out without having to power down and interrupt patient ventilation\n\nOther ventilation must have features:\n\nMust have recruitability assessment and lung recruitment (P/V Tool Pro)\nMust have patient ventilator synchronization (IntelliSync+)\nMust have CPR ventilation\nMust have Hamilton Connect Module\nMust have Hamilton Connect App\nMust have configurable touch screen to offer access to five graph and loop layout options\nMust be able to pause the screen and review the last 60 seconds of patient data\nMust provide a unique ventilator assurance feature, which, in the event of certain system failures, will continue to deliver ventilatory support as close to the preset settings\nMust have an integrated expiratory filtration system.\nMust be able to synchronize tools to help clinicians set the ventilator to adapt to their patients' unique needs\nMust have digital communication board which provides multiple USB ports for connections to external drives\nMust have HDMI output port\n\nThe list of draft characteristics is intended to be descriptive, not restrictive, of the supplies and/or services that are required.\nIf your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below. For instances where your company cannot meet the draft salient characteristic(s), please explain. For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.\n(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions. If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item.\n(12) What is your lead time to deliver all items?\n(13) Does your proposed equipment have FDA clearance (if needed)? Please specify what FDA clearance(s) have been obtained.\n(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(17) Please provide your SAM.gov Unique Entity ID number.\nResponses to this notice shall be submitted via email to Emiljan.Golemi@va.gov. Telephone responses will not be accepted. Responses must be received no later than Tuesday, February 18, 2025, by 4:00 PM PST.\nAll responses to this RFI/Sources Sought will be used for planning purposes only. Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26225Q0491","product_service_code":"6515"}],"due_at":"2025-02-19T00:00:00Z","due_date":"2025-02-18","closes_at":"2025-02-19T00:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-22T13:05:06.200863Z","principal_notice_id":"cb05d9d8e1f2422e9daa9736b7618ecc","description":{"text":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement. This is a Sources Sought/RFI only. The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this RFI/Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI/Sources Sought Notice, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office is seeking sources capable of providing Ventilator for the VA Long Beach Healthcare System and that can address the draft salient characteristics described below.\nBrandname Information:\nManufacturer & Part Number(s): Medtronic, 98OS1ENDIUUS\nType: PB980 PED TO ADULT - STANDARD BASE SHIPS WITH 1 PED/ADULT EXHALATION FILTER, 1 EVQ, 1 EVQ SEALS KIT, FLEX ARM, GOLD STANDARD CIRCUIT, OP MAN ON CD, POWER CORD AND SOFTWARE OPTIONS (PAV+, LEAK SYNC, BILEVEL 2.0, VV+, RESPIRATORY MECHANICS, TRENDING, TUBE COMPENSATION) AND 1 YEAR WARRANTY.\nEqual to product name: Ventilator\n\nManufacturer & Part Number(s): Medtronic, 10086042\nType: PROMO QS980BAT1-ZMPC- RECHARGEABLE LI-LON BATTERY - EACH VENTILATOR REQUIRES AT LEAST ONE BATTERY IN ORDER TO OPERATE.\nEqual to product name: RECHARGEABLE LI-LON BATTERY\n\nManufacturer & Part Number(s): Medtronic, SRVQ1-PB980AI\nType: PB980 PREMIUM SERVICE AGREEMENT\n\nEqual to product name: SERVICE AGREEMENT\n\nManufacturer & Part Number(s): Medtronic, 10086050\nType: 980 CYLINDER MOUNT X1\nEqual to product name: CYLINDER MOUNT\n\nManufacturer & Part Number(s): Medtronic, 10086049\nType: 980 HUMIDIFIER BRACKET X1\nEqual to product name: HUMIDIFIER BRACKET\n\nManufacturer & Part Number(s): Medtronic, 10114989\nType: 980 DC COMP UPGRADE KIT\nEqual to product name: DC COMP KIT\n\nSalient Characteristics:\n\nMust have ventilation modes and therapies for:\n\nVolume and flow control\nVolume targeted, adaptive pressure control\nIntelligent ventilation\nNoninvasive ventilation\nHigh flow\nflow sensor measures flow, pressure, and tidal volume\n\nMust have advanced monitoring for:\n\nVisualization of lung mechanics (Dynamic Lung)\nVisualization of the patient s ventilator dependence\nEsophageal pressure measurement\nCapnography\nSpO2 monitoring\n\nMust have safety features for:\n\nVentilated patients in the event of system failures.\nDelivering ventilatory support as close to the preset settings\nMust have stand-by mode which pauses ventilation and preserves settings when the patient is disconnected.\nMust auto-detects patient upon reconnection\nMust automatically resumes ventilation without the need to push additional buttons\nMust have additional screen located on the breath delivery unit (BDU) and provides a check of ventilator operation\nMust have custom filters to prevent infection and contamination\nMust have custom filters features of 99.97% filtration efficiency and meets CDC requirement for N100 filtration equivalency\nMust house up to two batteries\nMust have batteries that can be changed/swapped out without having to power down and interrupt patient ventilation\n\nOther ventilation must have features:\n\nMust have recruitability assessment and lung recruitment (P/V Tool Pro)\nMust have patient ventilator synchronization (IntelliSync+)\nMust have CPR ventilation\nMust have Hamilton Connect Module\nMust have Hamilton Connect App\nMust have configurable touch screen to offer access to five graph and loop layout options\nMust be able to pause the screen and review the last 60 seconds of patient data\nMust provide a unique ventilator assurance feature, which, in the event of certain system failures, will continue to deliver ventilatory support as close to the preset settings\nMust have an integrated expiratory filtration system.\nMust be able to synchronize tools to help clinicians set the ventilator to adapt to their patients' unique needs\nMust have digital communication board which provides multiple USB ports for connections to external drives\nMust have HDMI output port\n\nThe list of draft characteristics is intended to be descriptive, not restrictive, of the supplies and/or services that are required.\nIf your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:\n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below. For instances where your company cannot meet the draft salient characteristic(s), please explain. For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.\n(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions. If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified.\n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6?\n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?\n(11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item.\n(12) What is your lead time to deliver all items?\n(13) Does your proposed equipment have FDA clearance (if needed)? Please specify what FDA clearance(s) have been obtained.\n(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(17) Please provide your SAM.gov Unique Entity ID number.\nResponses to this notice shall be submitted via email to Emiljan.Golemi@va.gov. Telephone responses will not be accepted. Responses must be received no later than Tuesday, February 18, 2025, by 4:00 PM PST.\nAll responses to this RFI/Sources Sought will be used for planning purposes only. Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.","html":"THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT/RFI IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY. THIS IS NOT A SOLICITATION.\nTHE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 15.201(e).\nDISCLAIMER\nThis RFI is issued solely for information and planning purposes only and does not constitute a solicitation.  All information received in response to this RFI that is marked as proprietary will be handled accordingly.  IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.  Responders are solely responsible for all expenses associated with responding to this RFI.\nSOURCES SOUGHT/RFI DESCRIPTION\nThis is NOT a solicitation announcement.  This is a Sources Sought/RFI only.  The purpose of this Sources Sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this RFI/Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI/Sources Sought Notice, further RFIs and/or a solicitation or other announcements may be published.\nThe Department of Veterans Affairs (VA), VISN 22 Long Beach Network Contracting Office is seeking sources capable of providing Ventilator for the VA Long Beach Healthcare System and that can address the draft salient characteristics described below.  \nBrandname Information:\nManufacturer & Part Number(s): Medtronic, 98OS1ENDIUUS      \nType: PB980 PED TO ADULT - STANDARD BASE SHIPS WITH 1 PED/ADULT EXHALATION FILTER, 1 EVQ, 1 EVQ SEALS KIT, FLEX ARM, GOLD STANDARD CIRCUIT, OP MAN ON CD, POWER CORD AND SOFTWARE OPTIONS (PAV+, LEAK SYNC, BILEVEL 2.0, VV+, RESPIRATORY MECHANICS, TRENDING, TUBE COMPENSATION) AND 1 YEAR WARRANTY.\nEqual to product name: Ventilator \n\nManufacturer & Part Number(s): Medtronic, 10086042\nType: PROMO QS980BAT1-ZMPC- RECHARGEABLE LI-LON BATTERY - EACH VENTILATOR REQUIRES AT LEAST ONE BATTERY IN ORDER TO OPERATE.\nEqual to product name: RECHARGEABLE LI-LON BATTERY\n\nManufacturer & Part Number(s): Medtronic, SRVQ1-PB980AI \nType: PB980 PREMIUM SERVICE AGREEMENT\n\nEqual to product name: SERVICE AGREEMENT\n\nManufacturer & Part Number(s): Medtronic, 10086050\nType: 980 CYLINDER MOUNT X1\nEqual to product name: CYLINDER MOUNT\n\nManufacturer & Part Number(s): Medtronic, 10086049\nType: 980 HUMIDIFIER BRACKET X1 \nEqual to product name: HUMIDIFIER BRACKET\n\nManufacturer & Part Number(s): Medtronic, 10114989\nType: 980 DC COMP UPGRADE KIT\nEqual to product name: DC COMP KIT\n\nSalient Characteristics: \n\nMust have ventilation modes and therapies for:\n\nVolume and flow control \nVolume targeted, adaptive pressure control\nIntelligent ventilation\nNoninvasive ventilation \nHigh flow\nflow sensor measures flow, pressure, and tidal volume\n\nMust have advanced monitoring for:\n\nVisualization of lung mechanics (Dynamic Lung) \nVisualization of the patient s ventilator dependence \nEsophageal pressure measurement \nCapnography \nSpO2 monitoring\n\nMust have safety features for:\n\nVentilated patients in the event of system failures.\nDelivering ventilatory support as close to the preset settings\nMust have stand-by mode which pauses ventilation and preserves settings when the patient is disconnected.\nMust auto-detects patient upon reconnection\nMust automatically resumes ventilation without the need to push additional buttons\nMust have additional screen located on the breath delivery unit (BDU) and provides a check of ventilator operation\nMust have custom filters to prevent infection and contamination\nMust have custom filters features of 99.97% filtration efficiency and meets CDC requirement for N100 filtration equivalency\nMust house up to two batteries\nMust have batteries that can be changed/swapped out without having to power down and interrupt patient ventilation\n\nOther ventilation must have features:\n\nMust have recruitability assessment and lung recruitment (P/V Tool Pro) \nMust have patient ventilator synchronization (IntelliSync+) \nMust have CPR ventilation \nMust have Hamilton Connect Module \nMust have Hamilton Connect App\nMust have configurable touch screen to offer access to five graph and loop layout options\nMust be able to pause the screen and review the last 60 seconds of patient data\nMust provide a unique ventilator assurance feature, which, in the event of certain system failures, will continue to deliver ventilatory support as close to the preset settings \nMust have an integrated expiratory filtration system.\nMust be able to synchronize tools to help clinicians set the ventilator to adapt to their patients' unique needs\nMust have digital communication board which provides multiple USB ports for connections to external drives\nMust have HDMI output port\n\nThe list of draft characteristics is intended to be descriptive, not restrictive, of the supplies and/or services that are required. \nIf your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:  \n(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below.  For instances where your company cannot meet the draft salient characteristic(s), please explain.  For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.  \n(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions.  If none, please reply as N/A.\n(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.\n\n(4) Is your company considered small under the NAICS code identified in this RFI?\n(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?\n(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).\n(7) If you re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified. \n(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR Â§ 125.6? \n(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?\n(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? \n(11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item.\n(12) What is your lead time to deliver all items?\n(13) Does your proposed equipment have FDA clearance (if needed)?  Please specify what FDA clearance(s) have been obtained.\n(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).\n(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.\n(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.\n(17) Please provide your SAM.gov Unique Entity ID number.\nResponses to this notice shall be submitted via email to Emiljan.Golemi@va.gov. Telephone responses will not be accepted. Responses must be received no later than Tuesday, February 18, 2025, by 4:00 PM PST.  \nAll responses to this RFI/Sources Sought will be used for planning purposes only.  Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation.  If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.","origin":"detail"},"contacts":[{"name":"Emiljan Golemi","role":"primary","email":"emiljan.golemi@va.gov","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"85297","city":"Gilbert","state":"AZ","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"108d4f73ca864765bcbbe42a91904110","name":"36C26225Q0491.docx","kind":"file","mime_type":".docx","size_bytes":23261,"posted_at":"2025-02-13T01:11:42.462Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/108d4f73ca864765bcbbe42a91904110/download","mirrored":false},{"resource_id":"08fe688737b2443d850283aa8c9e0c21","name":"S05 RFI 36C26225Q0491-Ventilator.pdf","kind":"file","mime_type":".pdf","size_bytes":164440,"posted_at":"2025-02-13T01:11:42.462Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/08fe688737b2443d850283aa8c9e0c21/download","mirrored":false}],"awards":[],"related":[{"key":"36C26227Q0139","latest_notice_id":"156fef93406e495486eb1d4e805bb675","title":"6515--PYXIS IV PREP","solicitation_number":"36C26227Q0139","notice_type":"k","first_type":"k","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"541519","psc":"6515","set_aside":"SDVOSBC","state":"CA","county":"06073","county_name":"San Diego County","city":"0666000","city_name":"San Diego","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26227Q0146","latest_notice_id":"e2fc7d7b106d4b448a5b57cba568ddb4","title":"J041--KITCHEN HOOD PMIR - Base +4 ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0146","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"561790","psc":"J041","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T08:15:06.508374Z"},{"key":"36C26227Q0149","latest_notice_id":"99fd06e3089e4005bf945b21581e7d70","title":"J065--BRINE MAINTENANCE SVC - Base +4 OY ($0.00) [605] | POP: 01/01/2027 - 12/31/2031","solicitation_number":"36C26227Q0149","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"238220","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T07:05:05.540398Z"},{"key":"36C26227Q0063","latest_notice_id":"57c32e663caa45e58aecf5d9fcc6fe70","title":"J065--ALCON CONSTELLATION LXT AND EMBEDDED LASERS & ALCON CENTURION VISION PHACOEMULSIFICATION PMI SVCS","solicitation_number":"36C26227Q0063","notice_type":"k","first_type":"r","first_posted":"2026-10-21","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"36C26227Q0108","latest_notice_id":"c235634d3eac4a4eb2b35f80e4e896f8","title":"Q999--VA Loma Linda Healthcare System HCHV CRS Transitional Housing Sources Sought","solicitation_number":"36C26227Q0108","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"623220","psc":"Q999","set_aside":null,"state":"CA","county":"06071","county_name":"San Bernardino County","city":"0642370","city_name":"Loma Linda","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-08T02:35:10.339363Z"}],"similar_open":[{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"SPE2DS27T2443","latest_notice_id":"8f83cd5d4eb6487083e3a8ace6f5842d","title":"65--TEST KIT,MICRO SAMPLE","solicitation_number":"SPE2DS27T2443","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":null,"due_date":"2026-11-30","closes_at":"2026-12-01T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE2DS","office_name":"DLA TROOP SUPPORT","naics":"339112","psc":"65","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"SAMPLE: LINE 0001 QTY 4 UI EA DELIVER TO: AMC BAMC FSH - MM BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"75N98027Q00089","latest_notice_id":"ff12a0351f444b75a07784e65ceb294e","title":"65--COMBINED SYNOPSIS/SOLICITATION/ (Brand Name or Equ","solicitation_number":"75N98027Q00089","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-12-01T19:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":14,"indexable":false}