{"canonical":"https://sealedbidder.com/opportunities/36c26127q0067","key":"36C26127Q0067","url":"https://sealedbidder.com/opportunities/36c26127q0067","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-12-04T20:00:00Z","first_posted":"2026-09-25","last_posted":"2026-11-20","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"238210","psc":"J061","set_aside":"SDVOSBC","place_state":"NV","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"32031","place_county_name":"Washoe County","place_city":"3260600","place_city_name":"Reno","winner":null,"award_amount":null,"publications":[{"notice_id":"86fe7bfd33f94211b83e60d0768e8bdf","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"r","base_type":"r","posted":"2026-09-25","posted_at":"2026-09-25T16:55:43.893Z","due_at":"2026-10-02T19:00:00Z","due_date":"2026-10-02","cancelled":false,"archived":false,"archive_date":"2027-01-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/86fe7bfd33f94211b83e60d0768e8bdf/view","enriched":true,"history":[{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}]},{"notice_id":"e73346b7872440d687da8c6af71bb324","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"r","posted":"2026-10-09","posted_at":"2026-10-09T17:25:32.879Z","due_at":"2026-11-09T20:00:00Z","due_date":"2026-11-09","cancelled":false,"archived":false,"archive_date":"2027-02-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e73346b7872440d687da8c6af71bb324/view","enriched":true,"history":[{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}]},{"notice_id":"f99134b67e8346fa9009156ee48b604f","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-10-09","posted_at":"2026-10-09T17:28:33.683Z","due_at":"2026-11-09T20:00:00Z","due_date":"2026-11-09","cancelled":false,"archived":false,"archive_date":"2027-02-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f99134b67e8346fa9009156ee48b604f/view","enriched":true,"history":[{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}]},{"notice_id":"a4c067fbb213448cb4c1cfd59f2e3eca","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-10-14","posted_at":"2026-10-14T21:12:27.946Z","due_at":"2026-11-09T20:00:00Z","due_date":"2026-11-09","cancelled":false,"archived":false,"archive_date":"2026-12-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a4c067fbb213448cb4c1cfd59f2e3eca/view","enriched":true,"history":[{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"cc00104aeab1435c951f3a51fffe3472","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-10-15","posted_at":"2026-10-15T16:55:33.765Z","due_at":"2026-11-09T20:00:00Z","due_date":"2026-11-09","cancelled":false,"archived":false,"archive_date":"2026-12-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cc00104aeab1435c951f3a51fffe3472/view","enriched":true,"history":[{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}]},{"notice_id":"6835eae4408146c7b4031f06db70331c","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-10-19","posted_at":"2026-10-19T18:06:45.345Z","due_at":"2026-11-09T20:00:00Z","due_date":"2026-11-09","cancelled":false,"archived":false,"archive_date":"2026-12-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6835eae4408146c7b4031f06db70331c/view","enriched":true,"history":[{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}]},{"notice_id":"747e3038470743508da56094f9db5a0b","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-10-23","posted_at":"2026-10-23T17:12:49.307Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/747e3038470743508da56094f9db5a0b/view","enriched":true,"history":[{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"fc687fcca0b74ffba608726c6f7df020","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-10-23","posted_at":"2026-10-23T17:12:45.949Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fc687fcca0b74ffba608726c6f7df020/view","enriched":true,"history":[{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"fd54681dc9df433c925986385767ccf1","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-10-23","posted_at":"2026-10-23T17:13:06.759Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fd54681dc9df433c925986385767ccf1/view","enriched":true,"history":[{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"219d241784df49d2963081be55552807","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-11-02","posted_at":"2026-11-02T19:20:40.997Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/219d241784df49d2963081be55552807/view","enriched":true,"history":[{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"43d9186803094dcc8476ed17d213b68c","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-11-02","posted_at":"2026-11-02T19:20:29.797Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/43d9186803094dcc8476ed17d213b68c/view","enriched":true,"history":[{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"e77e5032b88d423b9871e8c5e66c4d0f","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-11-02","posted_at":"2026-11-02T19:20:34.742Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e77e5032b88d423b9871e8c5e66c4d0f/view","enriched":true,"history":[{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"0219242e57b54ac1bf223aaa8c9edc6c","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-11-06","posted_at":"2026-11-06T15:52:38.147Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0219242e57b54ac1bf223aaa8c9edc6c/view","enriched":true,"history":[{"index":15,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}]},{"notice_id":"5ba185d29f3a488b94841636606c1ef3","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-11-06","posted_at":"2026-11-06T15:24:19.296Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5ba185d29f3a488b94841636606c1ef3/view","enriched":true,"history":[{"index":15,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}]},{"notice_id":"9947934037dc4a6090fe9e7dc5e62ae5","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-11-06","posted_at":"2026-11-06T15:50:08.327Z","due_at":"2026-11-20T20:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9947934037dc4a6090fe9e7dc5e62ae5/view","enriched":true,"history":[{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"0abcb04abc194fa3b466c7a1410d7283","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-11-19","posted_at":"2026-11-19T23:55:03.630Z","due_at":"2026-12-04T20:00:00Z","due_date":"2026-12-04","cancelled":false,"archived":false,"archive_date":"2027-01-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0abcb04abc194fa3b466c7a1410d7283/view","enriched":true,"history":[{"index":15,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-19T23:55:03.630Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0abcb04abc194fa3b466c7a1410d7283","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}]},{"notice_id":"82c72dc14a3c44c98036ac47810a067b","title":"J061--Triennial Circuit Breaker and Feeder Testing","solicitation_number":"36C26127Q0067","notice_type":"o","base_type":"o","posted":"2026-11-20","posted_at":"2026-11-20T18:32:03.781Z","due_at":"2026-12-04T20:00:00Z","due_date":"2026-12-04","cancelled":false,"archived":false,"archive_date":"2027-01-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/82c72dc14a3c44c98036ac47810a067b/view","enriched":true,"history":[{"index":17,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-20T18:32:03.781Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"82c72dc14a3c44c98036ac47810a067b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":16,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-19T23:55:03.630Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0abcb04abc194fa3b466c7a1410d7283","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":15,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}]}],"latest_notice_id":"82c72dc14a3c44c98036ac47810a067b","first_type":"r","notices":[{"dates":{"posted":"2026-09-25","posted_at":"2026-09-25T16:55:43.893Z","created_at":"2026-09-25T16:55:42.730Z","modified_at":"2026-09-25T16:55:43.893Z","response_deadline":{"raw":"2026-10-02T12:00:00-07:00","utc":"2026-10-02T19:00:00Z","date":"2026-10-02","time":"12:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/86fe7bfd33f94211b83e60d0768e8bdf/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-09","archive_type":"auto_custom"},"history":[{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}],"contacts":[{"name":"Alex Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"86fe7bfd33f94211b83e60d0768e8bdf","lineage_id":"86fe7bfd33f94211b83e60d0768e8bdf","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-26T04:10:15.534491326Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"a43fa92deebebef22a51b6149790d6f555ad6c2961ccf0ff7a8e818d071eab5b","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-09-26T03:45:49.441710488Z"},"description":{"html":"No Solicitation is currently available. \n\nThis source's sought notice is for planning purposes only. All information contained herein is preliminary and subject to changes and/or cancellation at the discretion of the Government. Interested vendors shall respond to this notice voluntarily, and at no cost to the Government. The information requested will be used solely within the Department of Veterans Affairs to facilitate decision-making and will not be disclosed outside of the Government. Based upon information received in response to this Sources Sought Notice the Government shall decide on a procurement strategy, which shall include the type of small business set-aside, if appropriate. The eventual procurement strategy and set-aside, if appropriate, is solely within the discretion of the Government.  \n\nThe applicable North American Industry Classification System (NAICS) Code is 238210, Commercial and Institutional Building Construction, and the small business size standard is $19M. \n\nPotential Offerors must be registered in the System for Award Management (SAM) to be eligible for an award (See https://www.sam.gov/SAM/pages/public/index.jsf ). Potential Offerors must also have a current Online Representations and Certification Application on file with SAM.  Service-disabled veteran-owned Small Businesses and Veteran-Owned Small Businesses shall have their ownership and control verified by the Department of Veterans Affairs (VA) and be listed in the U.S. Small Business Administration (SBA) at https://www.sba.gov/. \nDescription of Services\nTriennial Circuit Breaker and Feeder Testing. \nLocation: VA Reno Health Care System (VARHCS), Reno, NV.\n\nThe Department of Veterans Affairs, Sierra Nevada Health Care System, Reno, NV has a requirement for Triennial Circuit Breaker and Feeder Testing per ANSI/NETA MTS. Contractor shall furnish all labor, materials, equipment, supervision and testing for the complete testing of Medium Voltage oil-cooled switches, liquid-filled and air-cooled transformers, low and medium voltage circuit breakers (225A 3-pole and above), and feeder cables. Work includes Very Low Frequency (VLF) testing of MV cables, torqueing and meggering of connections, functional testing/exercising of breakers, standard and infrared photography of electrical equipment, site visits of all MV vaults, overcurrent protective device coordination study with updated single-line diagrams, and arc flash hazard analysis with new labels for the entire campus. Testing shall be performed during off-hours (6PM-6AM and weekends), and photography during normal hours. Final report, photos, studies in PDF/CAD, and cost estimates for deficiencies and full MV cable replacement are required within 7 days of completion.\n\nPeriod of Performance (POP)\nPeriod of Performance: 60-90 days after NTP.\n\nSources Sought Information\nThe Government requests that interested parties review the Description of Services and provide the following capability information to the Contracting Specialist, Alex Arter, at alex.arter@va.gov,  by 12:00 PM PST on October 2, 2026:\n\nBusiness Size (Large/Small)\n\nBusiness Socio-Economic Status (SDVOSB, WOSB, 8(a), HUBZone, etc.)\n\nSAM record\n\nUEI number\n\nAbility and experience in managing projects between $250,000.00 and $750,000.00. Include general information and technical background describing your firm's experience on contracts requiring similar efforts to meet the program objectives [NETA testing, VLF, breaker testing 225A+, IR scanning, coordination/arc flash study].\n\nAnticipated Teaming Arrangements (if any).\n\nList of Projects (Government and Commercial) that are similar in scope and size.\n\nList of Sub-Contractors you intend to use on a project of this size and scope.\n\nHow does your company intend to meet the Limitations on Subcontracting as per 13 CFR 125.6?\n\nAre your Subcontractors from the local area or will they be coming from out of the area?  If out of the area, from where?\n\nInterested parties shall not submit more than 10 single-sided, type-written pages using Times New Roman 12-point font or larger. Published literature may be any number of pages. \n\nThe Government will use this information when determining its business type decision.\n  \nThis Sources Sought Notice is not to be construed as a commitment by the Government. \n\nNo contract will be awarded as a direct result of this announcement.","text":"No Solicitation is currently available.\n\nThis source's sought notice is for planning purposes only. All information contained herein is preliminary and subject to changes and/or cancellation at the discretion of the Government. Interested vendors shall respond to this notice voluntarily, and at no cost to the Government. The information requested will be used solely within the Department of Veterans Affairs to facilitate decision-making and will not be disclosed outside of the Government. Based upon information received in response to this Sources Sought Notice the Government shall decide on a procurement strategy, which shall include the type of small business set-aside, if appropriate. The eventual procurement strategy and set-aside, if appropriate, is solely within the discretion of the Government.\n\nThe applicable North American Industry Classification System (NAICS) Code is 238210, Commercial and Institutional Building Construction, and the small business size standard is $19M.\n\nPotential Offerors must be registered in the System for Award Management (SAM) to be eligible for an award (See https://www.sam.gov/SAM/pages/public/index.jsf ). Potential Offerors must also have a current Online Representations and Certification Application on file with SAM. Service-disabled veteran-owned Small Businesses and Veteran-Owned Small Businesses shall have their ownership and control verified by the Department of Veterans Affairs (VA) and be listed in the U.S. Small Business Administration (SBA) at https://www.sba.gov/.\nDescription of Services\nTriennial Circuit Breaker and Feeder Testing.\nLocation: VA Reno Health Care System (VARHCS), Reno, NV.\n\nThe Department of Veterans Affairs, Sierra Nevada Health Care System, Reno, NV has a requirement for Triennial Circuit Breaker and Feeder Testing per ANSI/NETA MTS. Contractor shall furnish all labor, materials, equipment, supervision and testing for the complete testing of Medium Voltage oil-cooled switches, liquid-filled and air-cooled transformers, low and medium voltage circuit breakers (225A 3-pole and above), and feeder cables. Work includes Very Low Frequency (VLF) testing of MV cables, torqueing and meggering of connections, functional testing/exercising of breakers, standard and infrared photography of electrical equipment, site visits of all MV vaults, overcurrent protective device coordination study with updated single-line diagrams, and arc flash hazard analysis with new labels for the entire campus. Testing shall be performed during off-hours (6PM-6AM and weekends), and photography during normal hours. Final report, photos, studies in PDF/CAD, and cost estimates for deficiencies and full MV cable replacement are required within 7 days of completion.\n\nPeriod of Performance (POP)\nPeriod of Performance: 60-90 days after NTP.\n\nSources Sought Information\nThe Government requests that interested parties review the Description of Services and provide the following capability information to the Contracting Specialist, Alex Arter, at alex.arter@va.gov, by 12:00 PM PST on October 2, 2026:\n\nBusiness Size (Large/Small)\n\nBusiness Socio-Economic Status (SDVOSB, WOSB, 8(a), HUBZone, etc.)\n\nSAM record\n\nUEI number\n\nAbility and experience in managing projects between $250,000.00 and $750,000.00. Include general information and technical background describing your firm's experience on contracts requiring similar efforts to meet the program objectives [NETA testing, VLF, breaker testing 225A+, IR scanning, coordination/arc flash study].\n\nAnticipated Teaming Arrangements (if any).\n\nList of Projects (Government and Commercial) that are similar in scope and size.\n\nList of Sub-Contractors you intend to use on a project of this size and scope.\n\nHow does your company intend to meet the Limitations on Subcontracting as per 13 CFR 125.6?\n\nAre your Subcontractors from the local area or will they be coming from out of the area? If out of the area, from where?\n\nInterested parties shall not submit more than 10 single-sided, type-written pages using Times New Roman 12-point font or larger. Published literature may be any number of pages.\n\nThe Government will use this information when determining its business type decision.\n\nThis Sources Sought Notice is not to be construed as a commitment by the Government.\n\nNo contract will be awarded as a direct result of this announcement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26127Q0067","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"street":"Department of Veterans Affairs VA Reno Health Care System 975 Kirman Ave"},"product_service_code":"J061"},{"dates":{"posted":"2026-10-09","posted_at":"2026-10-09T17:25:32.879Z","created_at":"2026-10-09T17:25:24.376Z","modified_at":"2026-10-09T17:28:33.683Z","response_deadline":{"raw":"2026-11-09T12:00:00-08:00","utc":"2026-11-09T20:00:00Z","date":"2026-11-09","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e73346b7872440d687da8c6af71bb324/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-02-16","archive_type":"auto_custom"},"history":[{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"e73346b7872440d687da8c6af71bb324","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-10T04:17:40.213187213Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"a2856dda0098e1405b39dd01315df91cccffe8775cebf2ef9e289f812d03bb06","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-10T03:49:37.295710722Z"},"description":{"html":"END OF SOLICITATION","text":"END OF SOLICITATION","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"dates":{"posted":"2026-10-09","posted_at":"2026-10-09T17:28:33.683Z","created_at":"2026-10-09T17:28:11.316Z","modified_at":"2026-10-09T17:28:33.689Z","response_deadline":{"raw":"2026-11-09T12:00:00-08:00","utc":"2026-11-09T20:00:00Z","date":"2026-11-09","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f99134b67e8346fa9009156ee48b604f/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-02-16","archive_type":"auto_custom"},"history":[{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"f99134b67e8346fa9009156ee48b604f","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-10T04:18:52.214336254Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"6d7a0fa1f9ce34f0c47d8b4757b37f9d907d6fbdcd26d805cc1be39466ffaac4","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-10T03:49:37.295710722Z"},"description":{"html":"<p>See attachements</p>","text":"See attachements","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"dates":{"posted":"2026-10-14","posted_at":"2026-10-14T21:12:27.946Z","created_at":"2026-10-14T21:12:13.901Z","modified_at":"2026-10-15T16:55:33.765Z","response_deadline":{"raw":"2026-11-09T12:00:00-08:00","utc":"2026-11-09T20:00:00Z","date":"2026-11-09","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a4c067fbb213448cb4c1cfd59f2e3eca/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-09","archive_type":"auto_custom"},"history":[{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"a4c067fbb213448cb4c1cfd59f2e3eca","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-16T00:08:01.969034031Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"0a6ff806fcee8061191cc4bef69101087041e3162906de7aa1c10275991a1593","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-15T04:24:39.658629845Z"},"description":{"html":"End of Solicitation Amendment","text":"End of Solicitation Amendment","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"dates":{"posted":"2026-10-15","posted_at":"2026-10-15T16:55:33.765Z","created_at":"2026-10-15T16:54:10.503Z","modified_at":"2026-10-15T16:55:33.768Z","response_deadline":{"raw":"2026-11-09T12:00:00-08:00","utc":"2026-11-09T20:00:00Z","date":"2026-11-09","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cc00104aeab1435c951f3a51fffe3472/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-09","archive_type":"auto_custom"},"history":[{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"cc00104aeab1435c951f3a51fffe3472","set_aside":{"code":"VSA","label":"Veteran-Owned Small Business Set-Aside (Department of Veterans Affairs)"},"lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-16T04:12:28.814503703Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"fe351052b0330acc59b44ebda3431a61817bdaeb2c14c9f9f4747feda5be1347","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-16T03:35:14.858266068Z"},"description":{"html":"<p>End of Solicitation Amendment</p>","text":"End of Solicitation Amendment","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","place_of_performance":{"zip":"89502","city":{"code":"60600","name":"Reno"},"state":{"code":"NV","name":"Nevada"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J061"},{"dates":{"posted":"2026-10-19","posted_at":"2026-10-19T18:06:45.345Z","created_at":"2026-10-19T18:05:11.771Z","modified_at":"2026-10-19T18:06:45.353Z","response_deadline":{"raw":"2026-11-09T12:00:00-08:00","utc":"2026-11-09T20:00:00Z","date":"2026-11-09","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6835eae4408146c7b4031f06db70331c/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-09","archive_type":"auto_custom"},"history":[{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"6835eae4408146c7b4031f06db70331c","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-20T04:09:32.088337042Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"8858c5c19551c9be45c12e0e876514feb34697014ed831b63ad1749a8ccf4ef9","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-20T03:47:26.591392148Z"},"description":{"html":"<p>End of Solicitation Amendment</p>","text":"End of Solicitation Amendment","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","place_of_performance":{"zip":"89502","city":{"code":"60600","name":"Reno"},"state":{"code":"NV","name":"Nevada"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J061"},{"dates":{"posted":"2026-10-23","posted_at":"2026-10-23T17:12:49.307Z","created_at":"2026-10-23T17:12:04.404Z","modified_at":"2026-10-23T17:13:06.759Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/747e3038470743508da56094f9db5a0b/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"747e3038470743508da56094f9db5a0b","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-24T04:15:28.118087348Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"e1f3484d7930ed9f7772d9f286c0a20f0f97f942adc3ff503e48fdb335f43f35","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-24T03:53:47.621077491Z"},"description":{"html":"1. VAAR 852.219-75 in the solicitation has box (iii), special trade construction contractors (75 percent), marked, while the requirement is coded J061 under NAICS 238210 and FAR 52.219-14 is also included. Please confirm that the 75 percent special trade limitation in box (iii) is the limitation that applies to this award. Confirmed. This requirement is solicited under NAICS 238210. The applicable limitation on subcontracting is VAAR 852.219-75(c)(iii), 75 percent for special trade construction contractors. Offeror must comply with that limitation and submit the signed certificate.\n2. The SAM.gov notice shows no set-aside, while the solicitation includes VAAR 852.219-73 (total set-aside for certified SDVOSBs). Please confirm that this requirement is a total SDVOSB set-aside. Confirmed. This is a total SDVOSB set-aside per VAAR 852.219-73 and SF1449 Block 10. NCO 21 will update the SAM.gov notice to reflect the set-aside. Offerors must be certified SDVOSB in SBA Veteran Small Business Certification at time of offer.\n3. Section B.1 states that invoices are submitted upon Government inspection and acceptance. Will VA accept two invoices, one after acceptance of field testing and one after acceptance of the coordination study and final report? Yes, the VA will take two invoices. Station/contracting will review these invoices for approval.\n4. Amendment 0001 added Attachment C27, Single-Line Schematics. Please confirm whether C27 and the Facility Single Line Diagram together define the full quantities to be tested (MV switches, MV cable runs and vaults, liquid-filled and dry-type transformers, circuit breakers 225A and above, and feeders), or provide an equipment list with counts. Please also identify the buildings covered by \"Day 12 + TBD, new facilities since 2017.\" In the past, a copy of 1-line diagrams was updated with color coding of each test component and a sheet with all quantiles and locations. This should be done to ensure vendor and FMS understands what scope is.\n5. For the coordination study and arc flash analysis, is the 2024 study model available to the contractor, and in what software? Is there a required software platform and CAD version for the deliverables? Yes. However, I was just informed that our 2020 circuit breaker testing is the performed format which we can provide.  \n6. Must the coordination study and arc flash analysis be sealed by a Professional Engineer, and if so, must the engineer be licensed in Nevada? Yes engineering seal is required. No, it does not need to be Nevada. In the past, the previous vendor has had an engineer on staff who did this.\n7. Please confirm that the five years of experience in the Contractor Requirements section is verified as a responsibility matter after quotes, and that the quote itself consists of price, the signed VAAR 852.219-75 certificate, amendment acknowledgments, and the items listed in FAR 52.212-1(a). Confirmed. Contractor Requirements Para 7.3 [5-year experience] will be evaluated as part of responsibility per FAR 9.104 after quotes, not as part of technical acceptability. For quote submission, see FAR 52.212-1(a) as supplemented by Addendum: price on B.2 Schedule, signed SF1449 Block 30 if required, acknowledgment of amendments per B.1 Para 4, signed VAAR 852.219-75 certificate, and proof of SDVOSB certification status. See also 52.212-3 if not in SAM.\n8. Will VA facility electricians perform switching for the outages, and will VA provide temporary power or generator support where emergency branch equipment is de-energized? It is preferred that be in the vendor s scope of work. But verbiage should state that it will be done with Electrical supervisor or designee s authority at time of switching. Vendor should be responsible for the switching of the medium voltage system (25KV). This would be the P/Q switch in Boiler plant yard, medium voltage switches, and transformers in/on the facility down stream from the P/Q switch. VA electricians may assist with switching for 600 volts and less to aid in the testing. This must be arranged in the presented schedule to ensure proper VA staff is available.\n9. What is the anticipated award date and the targeted notice-to-proceed window, so offerors can hold test crews for the night schedule? Anticipated award is within 2-3 weeks after the 11/9/2026 due date, subject to evaluations. NTP is intended ASAP after award per SOW 8.1. Offerors should plan to start coordination within 1 week of NTP. We will not require crews to be held prior to NTP.\n10. Will a site visit be offered before the quote due date, and if so, will attendance be optional? VA high encourages site visits to visit equipment types, locations, and quantities. This has not been a bidding mandate to attend, but is encouraged.\n11. Is there a deadline for questions, and will answers be issued by amendment? Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers that affect the SOW or terms will be issued by formal amendment to all offerors. Administrative clarifications may be answered by email.\n12. The quote submission method and address, and the question deadline. Quotes shall be submitted by email to alex.arter@va.gov. Quotes are due November 9, 2026 at 12:00 PM Pacific Time. File size: split emails if over 20MB. Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers affecting SOW/terms/pricing will be issued by formal amendment.\n13. Whether a site visit at the Ioannis A. Lougaris VAMC (Reno) will be held, and its date. A site visit is planned. Attendance will be optional. Date/time and meeting location will be issued by amendment once coordinated with Engineering. Offerors are encouraged to attend to verify existing conditions. No energized work will be performed during the site visit.\n14. Breaker and feeder quantities by voltage class (LV/MV), and whether protective relay testing and arc-flash label updates are in scope. From the previous tests. There are:\n11 MV Switches \n10 MV Transformers\n477 Circuit Breakers\n570 Feeder Cables \n27 LV Transformers\n                Protective relay testing and arc-flash label updates are in the scope. The arc-flash label updates are to have their associated room numbers on them and must be done with professional engravings (i.e. no hand drawn labels).\n15. Planned outage windows, and whether shutdowns must be after hours or on weekends. Yes. Per SOW 8.6, Electrical Testing shall be performed during Off Hours - 6:00 PM to 6:00 AM, weekends, and federal holidays. Photography work shall be performed during Normal Hours (Mon-Fri 6AM-6PM). The sequencing in SOW 8.1 shall be used as the basis for pricing. Final outage windows will be coordinated with the COR 2 weeks in advance per SOW 8.7 to minimize impact to patient care. \n16. Required standard and deliverables (for example, NETA MTS and VHA Directive 1028 reporting). The required standard and deliverables are to be adhered to the most concurrent American National Standard: Standard for Maintenance Testing Specification for Electrical Power Equipment and Systems (ANSI/NETA MTS) as well as the VHA Directive 1028. This can be found in section 7.1 and 7.14 in the SOW. Additional code requirements can also be found in this section.","text":"1. VAAR 852.219-75 in the solicitation has box (iii), special trade construction contractors (75 percent), marked, while the requirement is coded J061 under NAICS 238210 and FAR 52.219-14 is also included. Please confirm that the 75 percent special trade limitation in box (iii) is the limitation that applies to this award. Confirmed. This requirement is solicited under NAICS 238210. The applicable limitation on subcontracting is VAAR 852.219-75(c)(iii), 75 percent for special trade construction contractors. Offeror must comply with that limitation and submit the signed certificate.\n2. The SAM.gov notice shows no set-aside, while the solicitation includes VAAR 852.219-73 (total set-aside for certified SDVOSBs). Please confirm that this requirement is a total SDVOSB set-aside. Confirmed. This is a total SDVOSB set-aside per VAAR 852.219-73 and SF1449 Block 10. NCO 21 will update the SAM.gov notice to reflect the set-aside. Offerors must be certified SDVOSB in SBA Veteran Small Business Certification at time of offer.\n3. Section B.1 states that invoices are submitted upon Government inspection and acceptance. Will VA accept two invoices, one after acceptance of field testing and one after acceptance of the coordination study and final report? Yes, the VA will take two invoices. Station/contracting will review these invoices for approval.\n4. Amendment 0001 added Attachment C27, Single-Line Schematics. Please confirm whether C27 and the Facility Single Line Diagram together define the full quantities to be tested (MV switches, MV cable runs and vaults, liquid-filled and dry-type transformers, circuit breakers 225A and above, and feeders), or provide an equipment list with counts. Please also identify the buildings covered by \"Day 12 + TBD, new facilities since 2017.\" In the past, a copy of 1-line diagrams was updated with color coding of each test component and a sheet with all quantiles and locations. This should be done to ensure vendor and FMS understands what scope is.\n5. For the coordination study and arc flash analysis, is the 2024 study model available to the contractor, and in what software? Is there a required software platform and CAD version for the deliverables? Yes. However, I was just informed that our 2020 circuit breaker testing is the performed format which we can provide.\n6. Must the coordination study and arc flash analysis be sealed by a Professional Engineer, and if so, must the engineer be licensed in Nevada? Yes engineering seal is required. No, it does not need to be Nevada. In the past, the previous vendor has had an engineer on staff who did this.\n7. Please confirm that the five years of experience in the Contractor Requirements section is verified as a responsibility matter after quotes, and that the quote itself consists of price, the signed VAAR 852.219-75 certificate, amendment acknowledgments, and the items listed in FAR 52.212-1(a). Confirmed. Contractor Requirements Para 7.3 [5-year experience] will be evaluated as part of responsibility per FAR 9.104 after quotes, not as part of technical acceptability. For quote submission, see FAR 52.212-1(a) as supplemented by Addendum: price on B.2 Schedule, signed SF1449 Block 30 if required, acknowledgment of amendments per B.1 Para 4, signed VAAR 852.219-75 certificate, and proof of SDVOSB certification status. See also 52.212-3 if not in SAM.\n8. Will VA facility electricians perform switching for the outages, and will VA provide temporary power or generator support where emergency branch equipment is de-energized? It is preferred that be in the vendor s scope of work. But verbiage should state that it will be done with Electrical supervisor or designee s authority at time of switching. Vendor should be responsible for the switching of the medium voltage system (25KV). This would be the P/Q switch in Boiler plant yard, medium voltage switches, and transformers in/on the facility down stream from the P/Q switch. VA electricians may assist with switching for 600 volts and less to aid in the testing. This must be arranged in the presented schedule to ensure proper VA staff is available.\n9. What is the anticipated award date and the targeted notice-to-proceed window, so offerors can hold test crews for the night schedule? Anticipated award is within 2-3 weeks after the 11/9/2026 due date, subject to evaluations. NTP is intended ASAP after award per SOW 8.1. Offerors should plan to start coordination within 1 week of NTP. We will not require crews to be held prior to NTP.\n10. Will a site visit be offered before the quote due date, and if so, will attendance be optional? VA high encourages site visits to visit equipment types, locations, and quantities. This has not been a bidding mandate to attend, but is encouraged.\n11. Is there a deadline for questions, and will answers be issued by amendment? Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers that affect the SOW or terms will be issued by formal amendment to all offerors. Administrative clarifications may be answered by email.\n12. The quote submission method and address, and the question deadline. Quotes shall be submitted by email to alex.arter@va.gov. Quotes are due November 9, 2026 at 12:00 PM Pacific Time. File size: split emails if over 20MB. Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers affecting SOW/terms/pricing will be issued by formal amendment.\n13. Whether a site visit at the Ioannis A. Lougaris VAMC (Reno) will be held, and its date. A site visit is planned. Attendance will be optional. Date/time and meeting location will be issued by amendment once coordinated with Engineering. Offerors are encouraged to attend to verify existing conditions. No energized work will be performed during the site visit.\n14. Breaker and feeder quantities by voltage class (LV/MV), and whether protective relay testing and arc-flash label updates are in scope. From the previous tests. There are:\n11 MV Switches\n10 MV Transformers\n477 Circuit Breakers\n570 Feeder Cables\n27 LV Transformers\nProtective relay testing and arc-flash label updates are in the scope. The arc-flash label updates are to have their associated room numbers on them and must be done with professional engravings (i.e. no hand drawn labels).\n15. Planned outage windows, and whether shutdowns must be after hours or on weekends. Yes. Per SOW 8.6, Electrical Testing shall be performed during Off Hours - 6:00 PM to 6:00 AM, weekends, and federal holidays. Photography work shall be performed during Normal Hours (Mon-Fri 6AM-6PM). The sequencing in SOW 8.1 shall be used as the basis for pricing. Final outage windows will be coordinated with the COR 2 weeks in advance per SOW 8.7 to minimize impact to patient care.\n16. Required standard and deliverables (for example, NETA MTS and VHA Directive 1028 reporting). The required standard and deliverables are to be adhered to the most concurrent American National Standard: Standard for Maintenance Testing Specification for Electrical Power Equipment and Systems (ANSI/NETA MTS) as well as the VHA Directive 1028. This can be found in section 7.1 and 7.14 in the SOW. Additional code requirements can also be found in this section.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"dates":{"posted":"2026-10-23","posted_at":"2026-10-23T17:12:45.949Z","created_at":"2026-10-23T17:11:58.581Z","modified_at":"2026-10-23T17:12:49.307Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fc687fcca0b74ffba608726c6f7df020/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"fc687fcca0b74ffba608726c6f7df020","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-24T04:27:29.463720376Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"8fdf4a20fbf085535abcca75fa6bd68ac548c5fcd8a1df32a232e1ecb365884c","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-24T03:53:47.621077491Z"},"description":{"html":"1. VAAR 852.219-75 in the solicitation has box (iii), special trade construction contractors (75 percent), marked, while the requirement is coded J061 under NAICS 238210 and FAR 52.219-14 is also included. Please confirm that the 75 percent special trade limitation in box (iii) is the limitation that applies to this award. Confirmed. This requirement is solicited under NAICS 238210. The applicable limitation on subcontracting is VAAR 852.219-75(c)(iii), 75 percent for special trade construction contractors. Offeror must comply with that limitation and submit the signed certificate.\n2. The SAM.gov notice shows no set-aside, while the solicitation includes VAAR 852.219-73 (total set-aside for certified SDVOSBs). Please confirm that this requirement is a total SDVOSB set-aside. Confirmed. This is a total SDVOSB set-aside per VAAR 852.219-73 and SF1449 Block 10. NCO 21 will update the SAM.gov notice to reflect the set-aside. Offerors must be certified SDVOSB in SBA Veteran Small Business Certification at time of offer.\n3. Section B.1 states that invoices are submitted upon Government inspection and acceptance. Will VA accept two invoices, one after acceptance of field testing and one after acceptance of the coordination study and final report? Yes, the VA will take two invoices. Station/contracting will review these invoices for approval.\n4. Amendment 0001 added Attachment C27, Single-Line Schematics. Please confirm whether C27 and the Facility Single Line Diagram together define the full quantities to be tested (MV switches, MV cable runs and vaults, liquid-filled and dry-type transformers, circuit breakers 225A and above, and feeders), or provide an equipment list with counts. Please also identify the buildings covered by \"Day 12 + TBD, new facilities since 2017.\" In the past, a copy of 1-line diagrams was updated with color coding of each test component and a sheet with all quantiles and locations. This should be done to ensure vendor and FMS understands what scope is.\n5. For the coordination study and arc flash analysis, is the 2024 study model available to the contractor, and in what software? Is there a required software platform and CAD version for the deliverables? Yes. However, I was just informed that our 2020 circuit breaker testing is the performed format which we can provide.  \n6. Must the coordination study and arc flash analysis be sealed by a Professional Engineer, and if so, must the engineer be licensed in Nevada? Yes engineering seal is required. No, it does not need to be Nevada. In the past, the previous vendor has had an engineer on staff who did this.\n7. Please confirm that the five years of experience in the Contractor Requirements section is verified as a responsibility matter after quotes, and that the quote itself consists of price, the signed VAAR 852.219-75 certificate, amendment acknowledgments, and the items listed in FAR 52.212-1(a). Confirmed. Contractor Requirements Para 7.3 [5-year experience] will be evaluated as part of responsibility per FAR 9.104 after quotes, not as part of technical acceptability. For quote submission, see FAR 52.212-1(a) as supplemented by Addendum: price on B.2 Schedule, signed SF1449 Block 30 if required, acknowledgment of amendments per B.1 Para 4, signed VAAR 852.219-75 certificate, and proof of SDVOSB certification status. See also 52.212-3 if not in SAM.\n8. Will VA facility electricians perform switching for the outages, and will VA provide temporary power or generator support where emergency branch equipment is de-energized? It is preferred that be in the vendor s scope of work. But verbiage should state that it will be done with Electrical supervisor or designee s authority at time of switching. Vendor should be responsible for the switching of the medium voltage system (25KV). This would be the P/Q switch in Boiler plant yard, medium voltage switches, and transformers in/on the facility down stream from the P/Q switch. VA electricians may assist with switching for 600 volts and less to aid in the testing. This must be arranged in the presented schedule to ensure proper VA staff is available.\n9. What is the anticipated award date and the targeted notice-to-proceed window, so offerors can hold test crews for the night schedule? Anticipated award is within 2-3 weeks after the 11/9/2026 due date, subject to evaluations. NTP is intended ASAP after award per SOW 8.1. Offerors should plan to start coordination within 1 week of NTP. We will not require crews to be held prior to NTP.\n10. Will a site visit be offered before the quote due date, and if so, will attendance be optional? VA high encourages site visits to visit equipment types, locations, and quantities. This has not been a bidding mandate to attend, but is encouraged.\n11. Is there a deadline for questions, and will answers be issued by amendment? Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers that affect the SOW or terms will be issued by formal amendment to all offerors. Administrative clarifications may be answered by email.\n12. The quote submission method and address, and the question deadline. Quotes shall be submitted by email to alex.arter@va.gov. Quotes are due November 9, 2026 at 12:00 PM Pacific Time. File size: split emails if over 20MB. Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers affecting SOW/terms/pricing will be issued by formal amendment.\n13. Whether a site visit at the Ioannis A. Lougaris VAMC (Reno) will be held, and its date. A site visit is planned. Attendance will be optional. Date/time and meeting location will be issued by amendment once coordinated with Engineering. Offerors are encouraged to attend to verify existing conditions. No energized work will be performed during the site visit.\n14. Breaker and feeder quantities by voltage class (LV/MV), and whether protective relay testing and arc-flash label updates are in scope. From the previous tests. There are:\n11 MV Switches \n10 MV Transformers\n477 Circuit Breakers\n570 Feeder Cables \n27 LV Transformers\n                Protective relay testing and arc-flash label updates are in the scope. The arc-flash label updates are to have their associated room numbers on them and must be done with professional engravings (i.e. no hand drawn labels).\n15. Planned outage windows, and whether shutdowns must be after hours or on weekends. Yes. Per SOW 8.6, Electrical Testing shall be performed during Off Hours - 6:00 PM to 6:00 AM, weekends, and federal holidays. Photography work shall be performed during Normal Hours (Mon-Fri 6AM-6PM). The sequencing in SOW 8.1 shall be used as the basis for pricing. Final outage windows will be coordinated with the COR 2 weeks in advance per SOW 8.7 to minimize impact to patient care. \n16. Required standard and deliverables (for example, NETA MTS and VHA Directive 1028 reporting). The required standard and deliverables are to be adhered to the most concurrent American National Standard: Standard for Maintenance Testing Specification for Electrical Power Equipment and Systems (ANSI/NETA MTS) as well as the VHA Directive 1028. This can be found in section 7.1 and 7.14 in the SOW. Additional code requirements can also be found in this section.","text":"1. VAAR 852.219-75 in the solicitation has box (iii), special trade construction contractors (75 percent), marked, while the requirement is coded J061 under NAICS 238210 and FAR 52.219-14 is also included. Please confirm that the 75 percent special trade limitation in box (iii) is the limitation that applies to this award. Confirmed. This requirement is solicited under NAICS 238210. The applicable limitation on subcontracting is VAAR 852.219-75(c)(iii), 75 percent for special trade construction contractors. Offeror must comply with that limitation and submit the signed certificate.\n2. The SAM.gov notice shows no set-aside, while the solicitation includes VAAR 852.219-73 (total set-aside for certified SDVOSBs). Please confirm that this requirement is a total SDVOSB set-aside. Confirmed. This is a total SDVOSB set-aside per VAAR 852.219-73 and SF1449 Block 10. NCO 21 will update the SAM.gov notice to reflect the set-aside. Offerors must be certified SDVOSB in SBA Veteran Small Business Certification at time of offer.\n3. Section B.1 states that invoices are submitted upon Government inspection and acceptance. Will VA accept two invoices, one after acceptance of field testing and one after acceptance of the coordination study and final report? Yes, the VA will take two invoices. Station/contracting will review these invoices for approval.\n4. Amendment 0001 added Attachment C27, Single-Line Schematics. Please confirm whether C27 and the Facility Single Line Diagram together define the full quantities to be tested (MV switches, MV cable runs and vaults, liquid-filled and dry-type transformers, circuit breakers 225A and above, and feeders), or provide an equipment list with counts. Please also identify the buildings covered by \"Day 12 + TBD, new facilities since 2017.\" In the past, a copy of 1-line diagrams was updated with color coding of each test component and a sheet with all quantiles and locations. This should be done to ensure vendor and FMS understands what scope is.\n5. For the coordination study and arc flash analysis, is the 2024 study model available to the contractor, and in what software? Is there a required software platform and CAD version for the deliverables? Yes. However, I was just informed that our 2020 circuit breaker testing is the performed format which we can provide.\n6. Must the coordination study and arc flash analysis be sealed by a Professional Engineer, and if so, must the engineer be licensed in Nevada? Yes engineering seal is required. No, it does not need to be Nevada. In the past, the previous vendor has had an engineer on staff who did this.\n7. Please confirm that the five years of experience in the Contractor Requirements section is verified as a responsibility matter after quotes, and that the quote itself consists of price, the signed VAAR 852.219-75 certificate, amendment acknowledgments, and the items listed in FAR 52.212-1(a). Confirmed. Contractor Requirements Para 7.3 [5-year experience] will be evaluated as part of responsibility per FAR 9.104 after quotes, not as part of technical acceptability. For quote submission, see FAR 52.212-1(a) as supplemented by Addendum: price on B.2 Schedule, signed SF1449 Block 30 if required, acknowledgment of amendments per B.1 Para 4, signed VAAR 852.219-75 certificate, and proof of SDVOSB certification status. See also 52.212-3 if not in SAM.\n8. Will VA facility electricians perform switching for the outages, and will VA provide temporary power or generator support where emergency branch equipment is de-energized? It is preferred that be in the vendor s scope of work. But verbiage should state that it will be done with Electrical supervisor or designee s authority at time of switching. Vendor should be responsible for the switching of the medium voltage system (25KV). This would be the P/Q switch in Boiler plant yard, medium voltage switches, and transformers in/on the facility down stream from the P/Q switch. VA electricians may assist with switching for 600 volts and less to aid in the testing. This must be arranged in the presented schedule to ensure proper VA staff is available.\n9. What is the anticipated award date and the targeted notice-to-proceed window, so offerors can hold test crews for the night schedule? Anticipated award is within 2-3 weeks after the 11/9/2026 due date, subject to evaluations. NTP is intended ASAP after award per SOW 8.1. Offerors should plan to start coordination within 1 week of NTP. We will not require crews to be held prior to NTP.\n10. Will a site visit be offered before the quote due date, and if so, will attendance be optional? VA high encourages site visits to visit equipment types, locations, and quantities. This has not been a bidding mandate to attend, but is encouraged.\n11. Is there a deadline for questions, and will answers be issued by amendment? Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers that affect the SOW or terms will be issued by formal amendment to all offerors. Administrative clarifications may be answered by email.\n12. The quote submission method and address, and the question deadline. Quotes shall be submitted by email to alex.arter@va.gov. Quotes are due November 9, 2026 at 12:00 PM Pacific Time. File size: split emails if over 20MB. Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers affecting SOW/terms/pricing will be issued by formal amendment.\n13. Whether a site visit at the Ioannis A. Lougaris VAMC (Reno) will be held, and its date. A site visit is planned. Attendance will be optional. Date/time and meeting location will be issued by amendment once coordinated with Engineering. Offerors are encouraged to attend to verify existing conditions. No energized work will be performed during the site visit.\n14. Breaker and feeder quantities by voltage class (LV/MV), and whether protective relay testing and arc-flash label updates are in scope. From the previous tests. There are:\n11 MV Switches\n10 MV Transformers\n477 Circuit Breakers\n570 Feeder Cables\n27 LV Transformers\nProtective relay testing and arc-flash label updates are in the scope. The arc-flash label updates are to have their associated room numbers on them and must be done with professional engravings (i.e. no hand drawn labels).\n15. Planned outage windows, and whether shutdowns must be after hours or on weekends. Yes. Per SOW 8.6, Electrical Testing shall be performed during Off Hours - 6:00 PM to 6:00 AM, weekends, and federal holidays. Photography work shall be performed during Normal Hours (Mon-Fri 6AM-6PM). The sequencing in SOW 8.1 shall be used as the basis for pricing. Final outage windows will be coordinated with the COR 2 weeks in advance per SOW 8.7 to minimize impact to patient care.\n16. Required standard and deliverables (for example, NETA MTS and VHA Directive 1028 reporting). The required standard and deliverables are to be adhered to the most concurrent American National Standard: Standard for Maintenance Testing Specification for Electrical Power Equipment and Systems (ANSI/NETA MTS) as well as the VHA Directive 1028. This can be found in section 7.1 and 7.14 in the SOW. Additional code requirements can also be found in this section.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"dates":{"posted":"2026-10-23","posted_at":"2026-10-23T17:13:06.759Z","created_at":"2026-10-23T17:12:22.638Z","modified_at":"2026-10-23T17:13:06.759Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fd54681dc9df433c925986385767ccf1/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"fd54681dc9df433c925986385767ccf1","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-24T04:27:30.462919038Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"7ad90c01dd3b3907ef12603fd179fccc1d87717fe50685e00d817cec89950a9e","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-24T03:53:47.621077491Z"},"description":{"html":"1. VAAR 852.219-75 in the solicitation has box (iii), special trade construction contractors (75 percent), marked, while the requirement is coded J061 under NAICS 238210 and FAR 52.219-14 is also included. Please confirm that the 75 percent special trade limitation in box (iii) is the limitation that applies to this award. Confirmed. This requirement is solicited under NAICS 238210. The applicable limitation on subcontracting is VAAR 852.219-75(c)(iii), 75 percent for special trade construction contractors. Offeror must comply with that limitation and submit the signed certificate.\n2. The SAM.gov notice shows no set-aside, while the solicitation includes VAAR 852.219-73 (total set-aside for certified SDVOSBs). Please confirm that this requirement is a total SDVOSB set-aside. Confirmed. This is a total SDVOSB set-aside per VAAR 852.219-73 and SF1449 Block 10. NCO 21 will update the SAM.gov notice to reflect the set-aside. Offerors must be certified SDVOSB in SBA Veteran Small Business Certification at time of offer.\n3. Section B.1 states that invoices are submitted upon Government inspection and acceptance. Will VA accept two invoices, one after acceptance of field testing and one after acceptance of the coordination study and final report? Yes, the VA will take two invoices. Station/contracting will review these invoices for approval.\n4. Amendment 0001 added Attachment C27, Single-Line Schematics. Please confirm whether C27 and the Facility Single Line Diagram together define the full quantities to be tested (MV switches, MV cable runs and vaults, liquid-filled and dry-type transformers, circuit breakers 225A and above, and feeders), or provide an equipment list with counts. Please also identify the buildings covered by \"Day 12 + TBD, new facilities since 2017.\" In the past, a copy of 1-line diagrams was updated with color coding of each test component and a sheet with all quantiles and locations. This should be done to ensure vendor and FMS understands what scope is.\n5. For the coordination study and arc flash analysis, is the 2024 study model available to the contractor, and in what software? Is there a required software platform and CAD version for the deliverables? Yes. However, I was just informed that our 2020 circuit breaker testing is the performed format which we can provide.  \n6. Must the coordination study and arc flash analysis be sealed by a Professional Engineer, and if so, must the engineer be licensed in Nevada? Yes engineering seal is required. No, it does not need to be Nevada. In the past, the previous vendor has had an engineer on staff who did this.\n7. Please confirm that the five years of experience in the Contractor Requirements section is verified as a responsibility matter after quotes, and that the quote itself consists of price, the signed VAAR 852.219-75 certificate, amendment acknowledgments, and the items listed in FAR 52.212-1(a). Confirmed. Contractor Requirements Para 7.3 [5-year experience] will be evaluated as part of responsibility per FAR 9.104 after quotes, not as part of technical acceptability. For quote submission, see FAR 52.212-1(a) as supplemented by Addendum: price on B.2 Schedule, signed SF1449 Block 30 if required, acknowledgment of amendments per B.1 Para 4, signed VAAR 852.219-75 certificate, and proof of SDVOSB certification status. See also 52.212-3 if not in SAM.\n8. Will VA facility electricians perform switching for the outages, and will VA provide temporary power or generator support where emergency branch equipment is de-energized? It is preferred that be in the vendor s scope of work. But verbiage should state that it will be done with Electrical supervisor or designee s authority at time of switching. Vendor should be responsible for the switching of the medium voltage system (25KV). This would be the P/Q switch in Boiler plant yard, medium voltage switches, and transformers in/on the facility down stream from the P/Q switch. VA electricians may assist with switching for 600 volts and less to aid in the testing. This must be arranged in the presented schedule to ensure proper VA staff is available.\n9. What is the anticipated award date and the targeted notice-to-proceed window, so offerors can hold test crews for the night schedule? Anticipated award is within 2-3 weeks after the 11/9/2026 due date, subject to evaluations. NTP is intended ASAP after award per SOW 8.1. Offerors should plan to start coordination within 1 week of NTP. We will not require crews to be held prior to NTP.\n10. Will a site visit be offered before the quote due date, and if so, will attendance be optional? VA high encourages site visits to visit equipment types, locations, and quantities. This has not been a bidding mandate to attend, but is encouraged.\n11. Is there a deadline for questions, and will answers be issued by amendment? Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers that affect the SOW or terms will be issued by formal amendment to all offerors. Administrative clarifications may be answered by email.\n12. The quote submission method and address, and the question deadline. Quotes shall be submitted by email to alex.arter@va.gov. Quotes are due November 9, 2026 at 12:00 PM Pacific Time. File size: split emails if over 20MB. Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers affecting SOW/terms/pricing will be issued by formal amendment.\n13. Whether a site visit at the Ioannis A. Lougaris VAMC (Reno) will be held, and its date. A site visit is planned. Attendance will be optional. Date/time and meeting location will be issued by amendment once coordinated with Engineering. Offerors are encouraged to attend to verify existing conditions. No energized work will be performed during the site visit.\n14. Breaker and feeder quantities by voltage class (LV/MV), and whether protective relay testing and arc-flash label updates are in scope. From the previous tests. There are:\n11 MV Switches \n10 MV Transformers\n477 Circuit Breakers\n570 Feeder Cables \n27 LV Transformers\n                Protective relay testing and arc-flash label updates are in the scope. The arc-flash label updates are to have their associated room numbers on them and must be done with professional engravings (i.e. no hand drawn labels).\n15. Planned outage windows, and whether shutdowns must be after hours or on weekends. Yes. Per SOW 8.6, Electrical Testing shall be performed during Off Hours - 6:00 PM to 6:00 AM, weekends, and federal holidays. Photography work shall be performed during Normal Hours (Mon-Fri 6AM-6PM). The sequencing in SOW 8.1 shall be used as the basis for pricing. Final outage windows will be coordinated with the COR 2 weeks in advance per SOW 8.7 to minimize impact to patient care. \n16. Required standard and deliverables (for example, NETA MTS and VHA Directive 1028 reporting). The required standard and deliverables are to be adhered to the most concurrent American National Standard: Standard for Maintenance Testing Specification for Electrical Power Equipment and Systems (ANSI/NETA MTS) as well as the VHA Directive 1028. This can be found in section 7.1 and 7.14 in the SOW. Additional code requirements can also be found in this section.","text":"1. VAAR 852.219-75 in the solicitation has box (iii), special trade construction contractors (75 percent), marked, while the requirement is coded J061 under NAICS 238210 and FAR 52.219-14 is also included. Please confirm that the 75 percent special trade limitation in box (iii) is the limitation that applies to this award. Confirmed. This requirement is solicited under NAICS 238210. The applicable limitation on subcontracting is VAAR 852.219-75(c)(iii), 75 percent for special trade construction contractors. Offeror must comply with that limitation and submit the signed certificate.\n2. The SAM.gov notice shows no set-aside, while the solicitation includes VAAR 852.219-73 (total set-aside for certified SDVOSBs). Please confirm that this requirement is a total SDVOSB set-aside. Confirmed. This is a total SDVOSB set-aside per VAAR 852.219-73 and SF1449 Block 10. NCO 21 will update the SAM.gov notice to reflect the set-aside. Offerors must be certified SDVOSB in SBA Veteran Small Business Certification at time of offer.\n3. Section B.1 states that invoices are submitted upon Government inspection and acceptance. Will VA accept two invoices, one after acceptance of field testing and one after acceptance of the coordination study and final report? Yes, the VA will take two invoices. Station/contracting will review these invoices for approval.\n4. Amendment 0001 added Attachment C27, Single-Line Schematics. Please confirm whether C27 and the Facility Single Line Diagram together define the full quantities to be tested (MV switches, MV cable runs and vaults, liquid-filled and dry-type transformers, circuit breakers 225A and above, and feeders), or provide an equipment list with counts. Please also identify the buildings covered by \"Day 12 + TBD, new facilities since 2017.\" In the past, a copy of 1-line diagrams was updated with color coding of each test component and a sheet with all quantiles and locations. This should be done to ensure vendor and FMS understands what scope is.\n5. For the coordination study and arc flash analysis, is the 2024 study model available to the contractor, and in what software? Is there a required software platform and CAD version for the deliverables? Yes. However, I was just informed that our 2020 circuit breaker testing is the performed format which we can provide.\n6. Must the coordination study and arc flash analysis be sealed by a Professional Engineer, and if so, must the engineer be licensed in Nevada? Yes engineering seal is required. No, it does not need to be Nevada. In the past, the previous vendor has had an engineer on staff who did this.\n7. Please confirm that the five years of experience in the Contractor Requirements section is verified as a responsibility matter after quotes, and that the quote itself consists of price, the signed VAAR 852.219-75 certificate, amendment acknowledgments, and the items listed in FAR 52.212-1(a). Confirmed. Contractor Requirements Para 7.3 [5-year experience] will be evaluated as part of responsibility per FAR 9.104 after quotes, not as part of technical acceptability. For quote submission, see FAR 52.212-1(a) as supplemented by Addendum: price on B.2 Schedule, signed SF1449 Block 30 if required, acknowledgment of amendments per B.1 Para 4, signed VAAR 852.219-75 certificate, and proof of SDVOSB certification status. See also 52.212-3 if not in SAM.\n8. Will VA facility electricians perform switching for the outages, and will VA provide temporary power or generator support where emergency branch equipment is de-energized? It is preferred that be in the vendor s scope of work. But verbiage should state that it will be done with Electrical supervisor or designee s authority at time of switching. Vendor should be responsible for the switching of the medium voltage system (25KV). This would be the P/Q switch in Boiler plant yard, medium voltage switches, and transformers in/on the facility down stream from the P/Q switch. VA electricians may assist with switching for 600 volts and less to aid in the testing. This must be arranged in the presented schedule to ensure proper VA staff is available.\n9. What is the anticipated award date and the targeted notice-to-proceed window, so offerors can hold test crews for the night schedule? Anticipated award is within 2-3 weeks after the 11/9/2026 due date, subject to evaluations. NTP is intended ASAP after award per SOW 8.1. Offerors should plan to start coordination within 1 week of NTP. We will not require crews to be held prior to NTP.\n10. Will a site visit be offered before the quote due date, and if so, will attendance be optional? VA high encourages site visits to visit equipment types, locations, and quantities. This has not been a bidding mandate to attend, but is encouraged.\n11. Is there a deadline for questions, and will answers be issued by amendment? Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers that affect the SOW or terms will be issued by formal amendment to all offerors. Administrative clarifications may be answered by email.\n12. The quote submission method and address, and the question deadline. Quotes shall be submitted by email to alex.arter@va.gov. Quotes are due November 9, 2026 at 12:00 PM Pacific Time. File size: split emails if over 20MB. Submit questions NLT 11/02/2026 12PM PST to alex.arter@va.gov. Answers affecting SOW/terms/pricing will be issued by formal amendment.\n13. Whether a site visit at the Ioannis A. Lougaris VAMC (Reno) will be held, and its date. A site visit is planned. Attendance will be optional. Date/time and meeting location will be issued by amendment once coordinated with Engineering. Offerors are encouraged to attend to verify existing conditions. No energized work will be performed during the site visit.\n14. Breaker and feeder quantities by voltage class (LV/MV), and whether protective relay testing and arc-flash label updates are in scope. From the previous tests. There are:\n11 MV Switches\n10 MV Transformers\n477 Circuit Breakers\n570 Feeder Cables\n27 LV Transformers\nProtective relay testing and arc-flash label updates are in the scope. The arc-flash label updates are to have their associated room numbers on them and must be done with professional engravings (i.e. no hand drawn labels).\n15. Planned outage windows, and whether shutdowns must be after hours or on weekends. Yes. Per SOW 8.6, Electrical Testing shall be performed during Off Hours - 6:00 PM to 6:00 AM, weekends, and federal holidays. Photography work shall be performed during Normal Hours (Mon-Fri 6AM-6PM). The sequencing in SOW 8.1 shall be used as the basis for pricing. Final outage windows will be coordinated with the COR 2 weeks in advance per SOW 8.7 to minimize impact to patient care.\n16. Required standard and deliverables (for example, NETA MTS and VHA Directive 1028 reporting). The required standard and deliverables are to be adhered to the most concurrent American National Standard: Standard for Maintenance Testing Specification for Electrical Power Equipment and Systems (ANSI/NETA MTS) as well as the VHA Directive 1028. This can be found in section 7.1 and 7.14 in the SOW. Additional code requirements can also be found in this section.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"dates":{"posted":"2026-11-02","posted_at":"2026-11-02T19:20:40.997Z","created_at":"2026-11-02T19:20:19.010Z","modified_at":"2026-11-02T19:20:40.997Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/219d241784df49d2963081be55552807/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"219d241784df49d2963081be55552807","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-03T06:37:36.480419576Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"c738ef49d2ef3fe37b6a9ea91c5851211142d51dd70b06761c3d1965974552a0","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-11-03T04:48:34.968936277Z"},"description":{"html":"Drawing sets and permitted use: The published package includes C27 - Single-Line Schematics.pdf, marked original revision 03/28/2017, and Facility Single Line Diagram.pdf, revision B dated 09/04/2024. Both contain contractor use/reproduction notices. Please confirm whether these published PDFs may be shared with prospective subcontractors for quotation preparation and whether any handling restrictions apply. Which set controls where they differ? In particular, the older set excludes the Building 1D TN branch, while the newer set shows TN-LBSW; please confirm its current testing scope. They are allowed to be shared to subcontractors. TN-LBSW is to be included. \nExisting source files and reports: Are native CAD drawings, the previous triennial test report with equipment lists/results, and the existing coordination/arc-flash study and native model files (SKM, ETAP, or EasyPower) available? If so, please advise how bidders may obtain them and any permitted-use restrictions. We understand that updated PDF/CAD drawings and study deliverables are required, but have not confirmed what existing source files VA will furnish. See attached drawings/report. \nSwitching and staffing: Who is responsible for medium-voltage switching, isolation, lockout/tagout, and restoration during the Saturday outage? Will a VA electrician be assigned to each shift, and what support or equipment, if any, will VA provide? VA personal will be there to attend the Saturday outage. All equipment needed for testing is to be supplied by the contractor. VA electricians will be assigned to each shift.Â  \nFacility and equipment scope: Please provide the complete list of facilities added since 2017 and the associated equipment to be included, with building/equipment identifiers mapped to the drawings. The SOW's Day 12 plus TBD entry mentions the parking structure but does not provide an exhaustive list. The new parking garage. Please see attached for diagram. \nBadging and background checks: The solicitation incorporates FAR 52.204-9 and VAAR 852.204-70/852.204-72. Please confirm the Reno-specific credentialing and background-check requirements, applicable position/risk designation, required forms and sponsor/contact, expected processing lead time, and whether any interim or escorted access is permitted. Contractors are to check in with the police at the start of each shift for badges.","text":"Drawing sets and permitted use: The published package includes C27 - Single-Line Schematics.pdf, marked original revision 03/28/2017, and Facility Single Line Diagram.pdf, revision B dated 09/04/2024. Both contain contractor use/reproduction notices. Please confirm whether these published PDFs may be shared with prospective subcontractors for quotation preparation and whether any handling restrictions apply. Which set controls where they differ? In particular, the older set excludes the Building 1D TN branch, while the newer set shows TN-LBSW; please confirm its current testing scope. They are allowed to be shared to subcontractors. TN-LBSW is to be included.\nExisting source files and reports: Are native CAD drawings, the previous triennial test report with equipment lists/results, and the existing coordination/arc-flash study and native model files (SKM, ETAP, or EasyPower) available? If so, please advise how bidders may obtain them and any permitted-use restrictions. We understand that updated PDF/CAD drawings and study deliverables are required, but have not confirmed what existing source files VA will furnish. See attached drawings/report.\nSwitching and staffing: Who is responsible for medium-voltage switching, isolation, lockout/tagout, and restoration during the Saturday outage? Will a VA electrician be assigned to each shift, and what support or equipment, if any, will VA provide? VA personal will be there to attend the Saturday outage. All equipment needed for testing is to be supplied by the contractor. VA electricians will be assigned to each shift.Â\nFacility and equipment scope: Please provide the complete list of facilities added since 2017 and the associated equipment to be included, with building/equipment identifiers mapped to the drawings. The SOW's Day 12 plus TBD entry mentions the parking structure but does not provide an exhaustive list. The new parking garage. Please see attached for diagram.\nBadging and background checks: The solicitation incorporates FAR 52.204-9 and VAAR 852.204-70/852.204-72. Please confirm the Reno-specific credentialing and background-check requirements, applicable position/risk designation, required forms and sponsor/contact, expected processing lead time, and whether any interim or escorted access is permitted. Contractors are to check in with the police at the start of each shift for badges.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"dates":{"posted":"2026-11-02","posted_at":"2026-11-02T19:20:29.797Z","created_at":"2026-11-02T19:20:08.778Z","modified_at":"2026-11-02T19:20:34.742Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/43d9186803094dcc8476ed17d213b68c/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"43d9186803094dcc8476ed17d213b68c","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-03T06:44:17.397375104Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"55823d8e2a8d8da14d004a84166b6700a44bae7c265183750cde935c79114553","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-11-03T04:48:34.968936277Z"},"description":{"html":"Drawing sets and permitted use: The published package includes C27 - Single-Line Schematics.pdf, marked original revision 03/28/2017, and Facility Single Line Diagram.pdf, revision B dated 09/04/2024. Both contain contractor use/reproduction notices. Please confirm whether these published PDFs may be shared with prospective subcontractors for quotation preparation and whether any handling restrictions apply. Which set controls where they differ? In particular, the older set excludes the Building 1D TN branch, while the newer set shows TN-LBSW; please confirm its current testing scope. They are allowed to be shared to subcontractors. TN-LBSW is to be included. \nExisting source files and reports: Are native CAD drawings, the previous triennial test report with equipment lists/results, and the existing coordination/arc-flash study and native model files (SKM, ETAP, or EasyPower) available? If so, please advise how bidders may obtain them and any permitted-use restrictions. We understand that updated PDF/CAD drawings and study deliverables are required, but have not confirmed what existing source files VA will furnish. See attached drawings/report. \nSwitching and staffing: Who is responsible for medium-voltage switching, isolation, lockout/tagout, and restoration during the Saturday outage? Will a VA electrician be assigned to each shift, and what support or equipment, if any, will VA provide? VA personal will be there to attend the Saturday outage. All equipment needed for testing is to be supplied by the contractor. VA electricians will be assigned to each shift.Â  \nFacility and equipment scope: Please provide the complete list of facilities added since 2017 and the associated equipment to be included, with building/equipment identifiers mapped to the drawings. The SOW's Day 12 plus TBD entry mentions the parking structure but does not provide an exhaustive list. The new parking garage. Please see attached for diagram. \nBadging and background checks: The solicitation incorporates FAR 52.204-9 and VAAR 852.204-70/852.204-72. Please confirm the Reno-specific credentialing and background-check requirements, applicable position/risk designation, required forms and sponsor/contact, expected processing lead time, and whether any interim or escorted access is permitted. Contractors are to check in with the police at the start of each shift for badges.","text":"Drawing sets and permitted use: The published package includes C27 - Single-Line Schematics.pdf, marked original revision 03/28/2017, and Facility Single Line Diagram.pdf, revision B dated 09/04/2024. Both contain contractor use/reproduction notices. Please confirm whether these published PDFs may be shared with prospective subcontractors for quotation preparation and whether any handling restrictions apply. Which set controls where they differ? In particular, the older set excludes the Building 1D TN branch, while the newer set shows TN-LBSW; please confirm its current testing scope. They are allowed to be shared to subcontractors. TN-LBSW is to be included.\nExisting source files and reports: Are native CAD drawings, the previous triennial test report with equipment lists/results, and the existing coordination/arc-flash study and native model files (SKM, ETAP, or EasyPower) available? If so, please advise how bidders may obtain them and any permitted-use restrictions. We understand that updated PDF/CAD drawings and study deliverables are required, but have not confirmed what existing source files VA will furnish. See attached drawings/report.\nSwitching and staffing: Who is responsible for medium-voltage switching, isolation, lockout/tagout, and restoration during the Saturday outage? Will a VA electrician be assigned to each shift, and what support or equipment, if any, will VA provide? VA personal will be there to attend the Saturday outage. All equipment needed for testing is to be supplied by the contractor. VA electricians will be assigned to each shift.Â\nFacility and equipment scope: Please provide the complete list of facilities added since 2017 and the associated equipment to be included, with building/equipment identifiers mapped to the drawings. The SOW's Day 12 plus TBD entry mentions the parking structure but does not provide an exhaustive list. The new parking garage. Please see attached for diagram.\nBadging and background checks: The solicitation incorporates FAR 52.204-9 and VAAR 852.204-70/852.204-72. Please confirm the Reno-specific credentialing and background-check requirements, applicable position/risk designation, required forms and sponsor/contact, expected processing lead time, and whether any interim or escorted access is permitted. Contractors are to check in with the police at the start of each shift for badges.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"dates":{"posted":"2026-11-02","posted_at":"2026-11-02T19:20:34.742Z","created_at":"2026-11-02T19:20:12.142Z","modified_at":"2026-11-02T19:20:40.997Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e77e5032b88d423b9871e8c5e66c4d0f/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"e77e5032b88d423b9871e8c5e66c4d0f","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-03T07:15:52.354077924Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"99b21da8197cde7b81c2cba86b89f4750a4d8f5340b5e190ac77197c3e07023b","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-11-03T04:48:34.968936277Z"},"description":{"html":"Drawing sets and permitted use: The published package includes C27 - Single-Line Schematics.pdf, marked original revision 03/28/2017, and Facility Single Line Diagram.pdf, revision B dated 09/04/2024. Both contain contractor use/reproduction notices. Please confirm whether these published PDFs may be shared with prospective subcontractors for quotation preparation and whether any handling restrictions apply. Which set controls where they differ? In particular, the older set excludes the Building 1D TN branch, while the newer set shows TN-LBSW; please confirm its current testing scope. They are allowed to be shared to subcontractors. TN-LBSW is to be included. \nExisting source files and reports: Are native CAD drawings, the previous triennial test report with equipment lists/results, and the existing coordination/arc-flash study and native model files (SKM, ETAP, or EasyPower) available? If so, please advise how bidders may obtain them and any permitted-use restrictions. We understand that updated PDF/CAD drawings and study deliverables are required, but have not confirmed what existing source files VA will furnish. See attached drawings/report. \nSwitching and staffing: Who is responsible for medium-voltage switching, isolation, lockout/tagout, and restoration during the Saturday outage? Will a VA electrician be assigned to each shift, and what support or equipment, if any, will VA provide? VA personal will be there to attend the Saturday outage. All equipment needed for testing is to be supplied by the contractor. VA electricians will be assigned to each shift.Â  \nFacility and equipment scope: Please provide the complete list of facilities added since 2017 and the associated equipment to be included, with building/equipment identifiers mapped to the drawings. The SOW's Day 12 plus TBD entry mentions the parking structure but does not provide an exhaustive list. The new parking garage. Please see attached for diagram. \nBadging and background checks: The solicitation incorporates FAR 52.204-9 and VAAR 852.204-70/852.204-72. Please confirm the Reno-specific credentialing and background-check requirements, applicable position/risk designation, required forms and sponsor/contact, expected processing lead time, and whether any interim or escorted access is permitted. Contractors are to check in with the police at the start of each shift for badges.","text":"Drawing sets and permitted use: The published package includes C27 - Single-Line Schematics.pdf, marked original revision 03/28/2017, and Facility Single Line Diagram.pdf, revision B dated 09/04/2024. Both contain contractor use/reproduction notices. Please confirm whether these published PDFs may be shared with prospective subcontractors for quotation preparation and whether any handling restrictions apply. Which set controls where they differ? In particular, the older set excludes the Building 1D TN branch, while the newer set shows TN-LBSW; please confirm its current testing scope. They are allowed to be shared to subcontractors. TN-LBSW is to be included.\nExisting source files and reports: Are native CAD drawings, the previous triennial test report with equipment lists/results, and the existing coordination/arc-flash study and native model files (SKM, ETAP, or EasyPower) available? If so, please advise how bidders may obtain them and any permitted-use restrictions. We understand that updated PDF/CAD drawings and study deliverables are required, but have not confirmed what existing source files VA will furnish. See attached drawings/report.\nSwitching and staffing: Who is responsible for medium-voltage switching, isolation, lockout/tagout, and restoration during the Saturday outage? Will a VA electrician be assigned to each shift, and what support or equipment, if any, will VA provide? VA personal will be there to attend the Saturday outage. All equipment needed for testing is to be supplied by the contractor. VA electricians will be assigned to each shift.Â\nFacility and equipment scope: Please provide the complete list of facilities added since 2017 and the associated equipment to be included, with building/equipment identifiers mapped to the drawings. The SOW's Day 12 plus TBD entry mentions the parking structure but does not provide an exhaustive list. The new parking garage. Please see attached for diagram.\nBadging and background checks: The solicitation incorporates FAR 52.204-9 and VAAR 852.204-70/852.204-72. Please confirm the Reno-specific credentialing and background-check requirements, applicable position/risk designation, required forms and sponsor/contact, expected processing lead time, and whether any interim or escorted access is permitted. Contractors are to check in with the police at the start of each shift for badges.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"award":{"awardee":{}},"dates":{"posted":"2026-11-06","posted_at":"2026-11-06T15:52:38.147Z","created_at":"2026-11-06T15:51:03.535Z","modified_at":"2026-11-06T15:52:38.151Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0219242e57b54ac1bf223aaa8c9edc6c/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_id":"100163852","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":15,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"0219242e57b54ac1bf223aaa8c9edc6c","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T08:56:03.498724359Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"57c8b2c7b6efa6082d148b072197517b-27\"","fetched_at":"2026-11-07T04:49:22.571963856Z","row_sha256":"742659e598cf337f63e7409c9304ccab53761f81e09c13d640fe584e8548aefe","last_modified":"2026-11-07T04:30:20Z"},"updated_at":"2026-11-11T08:56:03.498724359Z","first_seen_at":"2026-11-07T04:49:22.571963856Z"},"description":{"html":"<p>End of Amendment</p>","text":"End of Amendment","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","place_of_performance":{"zip":"89502","city":{"code":"60600","name":"Reno"},"state":{"code":"NV","name":"Nevada"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J061"},{"award":{"awardee":{}},"dates":{"posted":"2026-11-06","posted_at":"2026-11-06T15:24:19.296Z","created_at":"2026-11-06T15:22:23.456Z","modified_at":"2026-11-06T15:50:08.327Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5ba185d29f3a488b94841636606c1ef3/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_id":"100163852","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":15,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"5ba185d29f3a488b94841636606c1ef3","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-08T00:26:17.099267156Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"57c8b2c7b6efa6082d148b072197517b-27\"","fetched_at":"2026-11-07T04:49:22.571963856Z","row_sha256":"15c333430a2fa783e516602944d00740613102b6943f249946fc263311ab512f","last_modified":"2026-11-07T04:30:20Z"},"updated_at":"2026-11-08T00:26:17.099267156Z","first_seen_at":"2026-11-07T04:49:22.571963856Z"},"description":{"html":"<p>Drawing sets and permitted use: The published package includes C27 - Single-Line Schematics.pdf, marked original revision 03/28/2017, and Facility Single Line Diagram.pdf, revision B dated 09/04/2024. Both contain contractor use/reproduction notices. Please confirm whether these published PDFs may be shared with prospective subcontractors for quotation preparation and whether any handling restrictions apply. Which set controls where they differ? In particular, the older set excludes the Building 1D TN branch, while the newer set shows TN-LBSW; please confirm its current testing scope. They are allowed to be shared to subcontractors. TN-LBSW is to be included. Existing source files and reports: Are native CAD drawings, the previous triennial test report with equipment lists/results, and the existing coordination/arc-flash study and native model files (SKM, ETAP, or EasyPower) available? If so, please advise how bidders may obtain them and any permitted-use restrictions. We understand that updated PDF/CAD drawings and study deliverables are required, but have not confirmed what existing source files VA will furnish. See attached drawings/report. Switching and staffing: Who is responsible for medium-voltage switching, isolation, lockout/tagout, and restoration during the Saturday outage? Will a VA electrician be assigned to each shift, and what support or equipment, if any, will VA provide? VA personal will be there to attend the Saturday outage. All equipment needed for testing is to be supplied by the contractor. VA electricians will be assigned to each shift.&Acirc;&nbsp; Facility and equipment scope: Please provide the complete list of facilities added since 2017 and the associated equipment to be included, with building/equipment identifiers mapped to the drawings. The SOW&#39;s Day 12 plus TBD entry mentions the parking structure but does not provide an exhaustive list. The new parking garage. Please see attached for diagram. Badging and background checks: The solicitation incorporates FAR 52.204-9 and VAAR 852.204-70/852.204-72. Please confirm the Reno-specific credentialing and background-check requirements, applicable position/risk designation, required forms and sponsor/contact, expected processing lead time, and whether any interim or escorted access is permitted. Contractors are to check in with the police at the start of each shift for badges.</p>","text":"Drawing sets and permitted use: The published package includes C27 - Single-Line Schematics.pdf, marked original revision 03/28/2017, and Facility Single Line Diagram.pdf, revision B dated 09/04/2024. Both contain contractor use/reproduction notices. Please confirm whether these published PDFs may be shared with prospective subcontractors for quotation preparation and whether any handling restrictions apply. Which set controls where they differ? In particular, the older set excludes the Building 1D TN branch, while the newer set shows TN-LBSW; please confirm its current testing scope. They are allowed to be shared to subcontractors. TN-LBSW is to be included. Existing source files and reports: Are native CAD drawings, the previous triennial test report with equipment lists/results, and the existing coordination/arc-flash study and native model files (SKM, ETAP, or EasyPower) available? If so, please advise how bidders may obtain them and any permitted-use restrictions. We understand that updated PDF/CAD drawings and study deliverables are required, but have not confirmed what existing source files VA will furnish. See attached drawings/report. Switching and staffing: Who is responsible for medium-voltage switching, isolation, lockout/tagout, and restoration during the Saturday outage? Will a VA electrician be assigned to each shift, and what support or equipment, if any, will VA provide? VA personal will be there to attend the Saturday outage. All equipment needed for testing is to be supplied by the contractor. VA electricians will be assigned to each shift.Â Facility and equipment scope: Please provide the complete list of facilities added since 2017 and the associated equipment to be included, with building/equipment identifiers mapped to the drawings. The SOW's Day 12 plus TBD entry mentions the parking structure but does not provide an exhaustive list. The new parking garage. Please see attached for diagram. Badging and background checks: The solicitation incorporates FAR 52.204-9 and VAAR 852.204-70/852.204-72. Please confirm the Reno-specific credentialing and background-check requirements, applicable position/risk designation, required forms and sponsor/contact, expected processing lead time, and whether any interim or escorted access is permitted. Contractors are to check in with the police at the start of each shift for badges.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","place_of_performance":{"zip":"89502","state":{"code":"NV","name":"Nevada"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J061"},{"award":{"awardee":{}},"dates":{"posted":"2026-11-06","posted_at":"2026-11-06T15:50:08.327Z","created_at":"2026-11-06T15:50:06.684Z","modified_at":"2026-11-06T15:52:38.147Z","response_deadline":{"raw":"2026-11-20T12:00:00-08:00","utc":"2026-11-20T20:00:00Z","date":"2026-11-20","time":"12:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9947934037dc4a6090fe9e7dc5e62ae5/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_id":"100163852","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-20","archive_type":"auto_custom"},"history":[{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"9947934037dc4a6090fe9e7dc5e62ae5","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-08T00:38:20.149441279Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"57c8b2c7b6efa6082d148b072197517b-27\"","fetched_at":"2026-11-07T04:49:22.571963856Z","row_sha256":"1be4558aa4abb0bc5d9e31b817e08822577afeea8326665a462c343bcd002a7a","last_modified":"2026-11-07T04:30:20Z"},"updated_at":"2026-11-08T00:38:20.149441279Z","first_seen_at":"2026-11-07T04:49:22.571963856Z"},"description":{"html":"End of Amendment","text":"End of Amendment","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"award":{"awardee":{}},"dates":{"posted":"2026-11-19","posted_at":"2026-11-19T23:55:03.630Z","created_at":"2026-11-19T23:55:00.938Z","modified_at":"2026-11-19T23:55:03.630Z","response_deadline":{"raw":"2026-12-04T12:00:00-08:00","utc":"2026-12-04T20:00:00Z","date":"2026-12-04","time":"12:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0abcb04abc194fa3b466c7a1410d7283/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_id":"100163852","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-03","archive_type":"auto_custom"},"history":[{"index":15,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-19T23:55:03.630Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0abcb04abc194fa3b466c7a1410d7283","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"0abcb04abc194fa3b466c7a1410d7283","lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T07:10:37.927189570Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"c16e5e0dfa0d95d43d743e49e58247ca-28\"","fetched_at":"2026-11-20T05:29:17.372835729Z","row_sha256":"f4f0f4f845494fb8d84e044c5b698193eebd3e7bfae001f5df53ab871e674afb","last_modified":"2026-11-20T04:30:19Z"},"updated_at":"2026-11-20T07:10:37.927189570Z","first_seen_at":"2026-11-20T05:29:17.372835729Z"},"description":{"html":"End of Amendment","text":"End of Amendment","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","product_service_code":"J061"},{"award":{"awardee":{}},"dates":{"posted":"2026-11-20","posted_at":"2026-11-20T18:32:03.781Z","created_at":"2026-11-20T18:28:38.765Z","modified_at":"2026-11-20T18:32:03.788Z","response_deadline":{"raw":"2026-12-04T12:00:00-08:00","utc":"2026-12-04T20:00:00Z","date":"2026-12-04","time":"12:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/82c72dc14a3c44c98036ac47810a067b/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"J061--Triennial Circuit Breaker and Feeder Testing","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_id":"100163852","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-03","archive_type":"auto_custom"},"history":[{"index":17,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-20T18:32:03.781Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"82c72dc14a3c44c98036ac47810a067b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":16,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-19T23:55:03.630Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0abcb04abc194fa3b466c7a1410d7283","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":15,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:52:38.147Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"0219242e57b54ac1bf223aaa8c9edc6c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":14,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:50:08.327Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"9947934037dc4a6090fe9e7dc5e62ae5","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":13,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-06T15:24:19.296Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"5ba185d29f3a488b94841636606c1ef3","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":12,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:40.997Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"219d241784df49d2963081be55552807","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":11,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:34.742Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"e77e5032b88d423b9871e8c5e66c4d0f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":10,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-02T19:20:29.797Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"43d9186803094dcc8476ed17d213b68c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":9,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:13:06.759Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fd54681dc9df433c925986385767ccf1","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":8,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:49.307Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"747e3038470743508da56094f9db5a0b","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":7,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-23T17:12:45.949Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"fc687fcca0b74ffba608726c6f7df020","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":6,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-19T18:06:45.345Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"6835eae4408146c7b4031f06db70331c","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":5,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-15T16:55:33.765Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"cc00104aeab1435c951f3a51fffe3472","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":4,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T21:12:27.946Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a4c067fbb213448cb4c1cfd59f2e3eca","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324"},{"index":3,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:28:33.683Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f99134b67e8346fa9009156ee48b604f","solicitation_number":"36C26127Q0067","parent_opportunity_id":"e73346b7872440d687da8c6af71bb324","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":2,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-09T17:25:32.879Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"e73346b7872440d687da8c6af71bb324","solicitation_number":"36C26127Q0067","related_opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf"},{"index":1,"title":"J061--Triennial Circuit Breaker and Feeder Testing","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-25T16:55:43.893Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"86fe7bfd33f94211b83e60d0768e8bdf","solicitation_number":"36C26127Q0067"}],"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"82c72dc14a3c44c98036ac47810a067b","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"e73346b7872440d687da8c6af71bb324","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T06:56:54.747753990Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"4291d09a3076ded14495d76f76d3450d-28\"","fetched_at":"2026-11-21T05:27:15.410755867Z","row_sha256":"7f44d9625eddc6bc1f065b07ac9632cc08ea8a70a49995091f2dfd13e1397896","last_modified":"2026-11-21T04:30:20Z"},"updated_at":"2026-11-21T06:56:54.747753990Z","first_seen_at":"2026-11-21T05:27:15.410755867Z"},"description":{"html":"<p>End of Amendment</p>","text":"End of Amendment","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26127Q0067","place_of_performance":{"zip":"89502","city":{"code":"60600","name":"Reno"},"state":{"code":"NV","name":"Nevada"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J061"}],"due_at":"2026-12-04T20:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","state":"NV","county":"32031","county_name":"Washoe County","city":"3260600","city_name":"Reno","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-21T05:30:25.727497Z","principal_notice_id":"82c72dc14a3c44c98036ac47810a067b","description":{"text":"End of Amendment","html":"<p>End of Amendment</p>","origin":"detail"},"contacts":[{"name":"Alex D Arter","role":"primary","email":"alex.arter@va.gov","title":"Contract Specialist"}],"place_of_performance":{"zip":"89502","city":{"code":"60600","name":"Reno"},"state":{"code":"NV","name":"Nevada"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"naics_codes":["238210"],"award":{"awardee":{}},"attachments":[{"resource_id":"1ee5726e076c4f2582faf55e1422b13c","name":"36C26127Q0067.docx","kind":"file","mime_type":".docx","size_bytes":28520,"posted_at":"2026-09-25T16:55:43.893Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1ee5726e076c4f2582faf55e1422b13c/download","mirrored":false},{"resource_id":"5e4495194b7246c397fec3189b428464","name":"36C26127Q0067_1.docx","kind":"file","mime_type":".docx","size_bytes":136466,"posted_at":"2026-10-09T17:25:32.879Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5e4495194b7246c397fec3189b428464/download","mirrored":false},{"resource_id":"0441b69e040146e094b650e859f5d03e","name":"Facility Floor Plan.pdf","kind":"file","mime_type":".pdf","size_bytes":6194674,"posted_at":"2026-10-09T17:25:32.879Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0441b69e040146e094b650e859f5d03e/download","mirrored":false},{"resource_id":"74afc04b6a5541fb9f257d8cef89d2f6","name":"Facility Single Line Diagram.pdf","kind":"file","mime_type":".pdf","size_bytes":654725,"posted_at":"2026-10-09T17:25:32.879Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/74afc04b6a5541fb9f257d8cef89d2f6/download","mirrored":false},{"resource_id":"fb2e4048697d4b1db48ec8d32e9504f0","name":"Wage Determination 2015-5595 Washoe County.pdf","kind":"file","mime_type":".pdf","size_bytes":4287634,"posted_at":"2026-10-09T17:25:32.879Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fb2e4048697d4b1db48ec8d32e9504f0/download","mirrored":false},{"resource_id":"06528968fe254cbaa6633fd954a4fa2a","name":"36C26127Q0067 0001.docx","kind":"file","mime_type":".docx","size_bytes":27330,"posted_at":"2026-10-14T21:12:27.946Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/06528968fe254cbaa6633fd954a4fa2a/download","mirrored":false},{"resource_id":"7f61f40258c24530b3c9f7913a0dbdd9","name":"C27 - Single-Line Schematics.pdf","kind":"file","mime_type":".pdf","size_bytes":1345588,"posted_at":"2026-10-14T21:12:27.946Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7f61f40258c24530b3c9f7913a0dbdd9/download","mirrored":false},{"resource_id":"1bc10bd279fc47beb632ec48ef381cf2","name":"36C26127Q0067 0002.docx","kind":"file","mime_type":".docx","size_bytes":31391,"posted_at":"2026-10-23T17:13:06.759Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1bc10bd279fc47beb632ec48ef381cf2/download","mirrored":false},{"resource_id":"5dae603e75194ce18fbedbde497bede7","name":"D1014-8 C03 36C26124P0555_TESTING REPORT.pdf","kind":"file","mime_type":".pdf","size_bytes":59046316,"posted_at":"2026-10-23T17:13:06.759Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5dae603e75194ce18fbedbde497bede7/download","mirrored":false},{"resource_id":"6eb3e8edb3ab420789a3bf66400c5905","name":"36C26127Q0067 0003.docx","kind":"file","mime_type":".docx","size_bytes":19999,"posted_at":"2026-11-02T19:20:40.997Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6eb3e8edb3ab420789a3bf66400c5905/download","mirrored":false},{"resource_id":"7bc2caeea3ba43bfbb15e09eac67b706","name":"Attachment F- Plans and diagrams REVISED 11-13-23.pdf","kind":"file","mime_type":".pdf","size_bytes":10321188,"posted_at":"2026-11-02T19:20:40.997Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7bc2caeea3ba43bfbb15e09eac67b706/download","mirrored":false},{"resource_id":"aa76ce9fea73429da483bcc1a34ff179","name":"36C26127Q0067 0004.docx","kind":"file","mime_type":".docx","size_bytes":17639,"posted_at":"2026-11-06T15:50:08.327Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/aa76ce9fea73429da483bcc1a34ff179/download","mirrored":false},{"resource_id":"e6e605e2228e4e528dbe74bd20f1c3ea","name":"Reno Site Visit 11-05.pdf","kind":"file","mime_type":".pdf","size_bytes":309528,"posted_at":"2026-11-06T15:50:08.327Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e6e605e2228e4e528dbe74bd20f1c3ea/download","mirrored":false},{"resource_id":"1dde98fc624e4981ab27ea674970479a","name":"36C26127Q0067 0005.docx","kind":"file","mime_type":".docx","size_bytes":17709,"posted_at":"2026-11-19T23:55:03.630Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/1dde98fc624e4981ab27ea674970479a/download","mirrored":false}],"awards":[],"related":[{"key":"36C26126Q1297","latest_notice_id":"a62af13fb8674f5c9add72a5c2417296","title":"Z2DA--654-24-004 | Remediate Old Parking Garage","solicitation_number":"36C26126Q1297","notice_type":"o","first_type":"r","first_posted":"2026-09-29","last_posted":"2026-11-18","notices":9,"due_at":"2026-11-25T23:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"NV","county":"32031","county_name":"Washoe County","city":"3260600","city_name":"Reno","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26127Q0175","latest_notice_id":"6ff0b83d55464667808667710e947d25","title":"N099--Install ID Storage Shed Project Number 593-27-307 North Las Vegas, NV","solicitation_number":"36C26127Q0175","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"236220","psc":"N099","set_aside":null,"state":"NV","county":"32003","county_name":"Clark County","city":"3251800","city_name":"North Las Vegas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26127Q0169","latest_notice_id":"9989888cf8614c8e87f9894ee00a31e7","title":"J012--Dry-Type Fire Suppression System","solicitation_number":"36C26127Q0169","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-30T23:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"811310","psc":"J012","set_aside":null,"state":"CA","county":"06085","county_name":"Santa Clara County","city":"0655282","city_name":"Palo Alto","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26127Q0167","latest_notice_id":"28c31f3c4e3541cfa45f402ef2a11308","title":"7310--TRANSPORT CART AND SERVING TRAY_ Nutrition & Food Service","solicitation_number":"36C26127Q0167","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-30T23:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T23:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"333241","psc":"7310","set_aside":null,"state":"CA","county":"06085","county_name":"Santa Clara County","city":"0655282","city_name":"Palo Alto","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C26127Q0082","latest_notice_id":"1a5811f6c2cb4c5d887f8b4b9ad3c664","title":"Z1DZ--Project No. 640A0-27-104, Replace Roof at Building 347 - Menlo Park","solicitation_number":"36C26127Q0082","notice_type":"k","first_type":"k","first_posted":"2026-10-20","last_posted":"2026-11-12","notices":3,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"236220","psc":"Z1DZ","set_aside":"SDVOSBC","state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open":[{"key":"1240LU26Q0132","latest_notice_id":"7772e7cbaf1a46409b142ded751c8ec8","title":"USDA Forest Service - Hebgen Lake District Office Network Cabling and IT Room Improvements","solicitation_number":"1240LU26Q0132","notice_type":"k","first_type":"k","first_posted":"2026-09-24","last_posted":"2026-11-05","notices":4,"due_at":"2026-11-26T00:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1240LU","office_name":"USDA-FS, CSA INTERMOUNTAIN 9","naics":"238210","psc":"N061","set_aside":"SBA","state":"MT","county":"30031","county_name":"Gallatin County","city":"3079525","city_name":"West Yellowstone","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"127EAW27Q0002","latest_notice_id":"59c24c6aad3541448f35b465324ba88b","title":"Forest Service - Solar Batteries Frenchman Work Center","solicitation_number":"127EAW27Q0002","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-28T00:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-127EAW","office_name":"USDA-FS, CSA SOUTHWEST 6","naics":"238210","psc":"N061","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open_total":39,"indexable":true}