{"canonical":"https://sealedbidder.com/opportunities/36c26126q1003","key":"36C26126Q1003","url":"https://sealedbidder.com/opportunities/36c26126q1003","title":"4110--Helmer iPR245-GX i.Series Pharmaceutical Refrigerator (Brand Name or Equal)","solicitation_number":"36C26126Q1003","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-19T23:00:00Z","first_posted":"2026-08-13","last_posted":"2026-08-13","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"333415","psc":"4110","set_aside":null,"place_state":null,"place_scope":"overseas","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 4110)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"edf296f080b341baacd1697b4c104a61","title":"4110--Helmer iPR245-GX i.Series Pharmaceutical Refrigerator (Brand Name or Equal)","solicitation_number":"36C26126Q1003","notice_type":"r","base_type":"r","posted":"2026-08-13","posted_at":"2026-08-13T23:14:52.623Z","due_at":"2026-08-19T23:00:00Z","due_date":"2026-08-19","cancelled":false,"archived":true,"archive_date":"2026-09-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/edf296f080b341baacd1697b4c104a61/view","enriched":true,"history":[{"index":3,"title":"4110--Helmer iPR245-GX i.Series Pharmaceutical Refrigerator (Brand Name or Equal)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-13T23:14:52.623Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"edf296f080b341baacd1697b4c104a61","solicitation_number":"36C26126Q1003"}]}],"latest_notice_id":"edf296f080b341baacd1697b4c104a61","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-08-13","posted_at":"2026-08-13T23:14:52.623Z","created_at":"2026-08-13T23:14:51.414Z","modified_at":"2026-09-03T05:07:22.123Z","response_deadline":{"raw":"2026-08-19T16:00:00-07:00","utc":"2026-08-19T23:00:00Z","date":"2026-08-19","time":"16:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/edf296f080b341baacd1697b4c104a61/view"},"naics":{"codes":["333415"],"primary":"333415"},"title":"4110--Helmer iPR245-GX i.Series Pharmaceutical Refrigerator (Brand Name or Equal)","agency":{"office":{"code":"36C261","name":"261-NETWORK CONTRACT OFFICE 21 (36C261)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"organization_id":"100163852","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-03","archive_type":"auto_custom"},"history":[{"index":3,"title":"4110--Helmer iPR245-GX i.Series Pharmaceutical Refrigerator (Brand Name or Equal)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-13T23:14:52.623Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"edf296f080b341baacd1697b4c104a61","solicitation_number":"36C26126Q1003"}],"contacts":[{"name":"Cristina Mae Lansangan","role":"primary","email":"cristina.lansangan@va.gov","phone":"011-632-833-4566","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"edf296f080b341baacd1697b4c104a61","lineage_id":"edf296f080b341baacd1697b4c104a61","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-25T01:16:04.732202500Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"5c5118246420ef5df6a000530e14813027f4b68fb8112cefa550be23e41f1073","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-25T01:16:04.732202500Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"SOURCES SOUGHT NOTICE   BRAND NAME OR EQUAL - Helmer iPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft. for VA Manila Outpatient Clinic \n\nThis is a Sources Sought Notice issued solely for information and planning purposes ONLY. It does not constitute a solicitation. Responses to this notice will assist the Government in identifying potential sources capable of providing the required equipment. No reimbursement will be made for any costs associated with providing information in response to this notice.\n\nThe Department of Veterans Affairs, Manila Outpatient Clinic is seeking potential sources capable of providing two (2) units Helmer iPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft, (Brand name or Equal).\n\nThe essential/significant physical, functional or performance characteristics of the requirement are:\n\nApplication, Rating, & Electrical Data \nApplication \nHigh performance storage of medical and scientific products \nStorage Volume \n44.9 cu ft | 1271 L \nTemperature Range \n+2Â°C to +10Â°C \nSet Point \n+5Â°C \nElectrical Power \n115V 60Hz | 220-240V 50-60Hz \nCertification/Agency Listing \nQPS (Certified to UL and CSA Standards) \nIEC/UL61010-2-011: 2016 | IEC 61010-1:2010, AMD1:2016 ETL certified to NSF/ANSI 456 Vaccine Storage Standard \nEnergy Star \nYes, ENERGY STARÂ® Certified High Performance Refrigerator \nAmbient Operating Temperature \n+15Â°C to +32Â°C | +59Â°F to +90Â°F \nRefrigeration \nRefrigeration System \nVCC compressor-based, forced-air hydrocarbon \nCompressor \nHermetic, variable speed (VCC). Rated speed range: 1300-4000 rpm \nCondenser Type \nAir-cooled fin and tube, sealed \nDefrost Method \nAutomatic \nRefrigerant \nR600a, Isobutane, EPA SNAP compliant \nController / Configuration Settings \nUser Interface \ni.C3Â® color touchscreen, door mounted, 7in | 177mm, Â°C or Â°F \nPower Switch \nOn/Off \nController Type \nMicroprocessor with touchscreen input & display \nSecurity \nLockable doors, password protected settings \nControl Sensor \nRTD, stainless steel \niPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456 Vaccine Storage Certified Labeling and Certificate of Calibration\n\nCommunication Ports \nUSB, Remote alarm contacts, RJ45 (Ethernet). API available for Ethernet connectivity development \nPower Failure Alarm \nYes \nHigh/Low Alarms - Tests \nYes, fully adjustable, automatic (Peltier) testing \nDoor Ajar Alarm \nYes, fully adjustable \nCondenser Temperature Alarm \nYes, fully adjustable \nMin/Max Temperature \nYes, display and reset \nDownload \nYes, via USB. CSV and PDF \nEvent Log \nYes, all alarms, door openings, download via USB \nTemperature Log \nYes, download via USB \nInteractive Temperature Graph \nYes \nTemperature Monitoring Ballast \nYes, two 4 oz bottles with screw caps, solid ballasts optional \nBattery Back-up \nYes, 20 hr. display & alarm back up for i.C3Â® touchscreen | Rechargeable 12V, lead acid \nInterior Storage (w x h x d) \n2 ventilated, powder coated shelves, adjustable \n22.5 x 21.9 in | 572 x 557 mm, 100 lb | 46 kg max capacity/shelf \n12 ventilated, powder coated, pull-out drawers, adjustable \n21.5 x 3.9 x 22 in | 546 x 100 x 560 mm, 100 lb | 46 kg max capacity/drawer \niPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456  Vaccine Storage Certified Labeling and Certificate of Calibration\n\nOptions | Accessories \nStainless steel interior, Chart recorder, Chart paper, Leveling feet, Solid ballast, Remote alarms, Floor and Wall bracket kit, Seismic anchoring kit, Storage trays, Screen protector, Locking drawer, Solid or heated glass doors, Top cover, Side-wall access ports, Temperature validation, Validation guide (IQ/OQ), Extended warranty \nCertificate of Calibration \nYes, generated with ISO 17025 certified, NIST traceable thermometer \nWarranty \nRel.i  Plus Warranty - 7 years compressor, 2 years parts, 1 year labor \nOutside US and Canada - Contact your distributor for warranty information \n\nThe anticipated NAICS code for this requirement is 333415   Air-Conditioning and warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing with Size Standard of 1,250 employees. \n\nNo set-aside determination has been made at this time. The Government is seeking information to support acquisition planning and any applicable socioeconomic determination.\n\nOnly firms interested and capable should send their information and any questions by email to Cristina.lansangan@va.gov no later than 4:00 PM Pacific Standard Time, August 19, 2026.\n\nPlease provide the following information in your response:\nCompany Name and UEI\nPoint of Contact: Name, Phone Number and E-mail address\nSBA Socio-economic Status \nCapability Statement\nIndicate whether this equipment is available under GSA/FSS/NAC contract, including contract number and expiry date \nAuthorized Distributor Letter (if applicable)\nEstimated Price\n\n\nDISCLAIMER\n\nThis Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly. The Government will not compensate an offeror for providing information in response to this notice. Furthermore, the Government reserves the right to cancel this requirement at its discretion.","text":"SOURCES SOUGHT NOTICE BRAND NAME OR EQUAL - Helmer iPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft. for VA Manila Outpatient Clinic\n\nThis is a Sources Sought Notice issued solely for information and planning purposes ONLY. It does not constitute a solicitation. Responses to this notice will assist the Government in identifying potential sources capable of providing the required equipment. No reimbursement will be made for any costs associated with providing information in response to this notice.\n\nThe Department of Veterans Affairs, Manila Outpatient Clinic is seeking potential sources capable of providing two (2) units Helmer iPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft, (Brand name or Equal).\n\nThe essential/significant physical, functional or performance characteristics of the requirement are:\n\nApplication, Rating, & Electrical Data\nApplication\nHigh performance storage of medical and scientific products\nStorage Volume\n44.9 cu ft | 1271 L\nTemperature Range\n+2Â°C to +10Â°C\nSet Point\n+5Â°C\nElectrical Power\n115V 60Hz | 220-240V 50-60Hz\nCertification/Agency Listing\nQPS (Certified to UL and CSA Standards)\nIEC/UL61010-2-011: 2016 | IEC 61010-1:2010, AMD1:2016 ETL certified to NSF/ANSI 456 Vaccine Storage Standard\nEnergy Star\nYes, ENERGY STARÂ® Certified High Performance Refrigerator\nAmbient Operating Temperature\n+15Â°C to +32Â°C | +59Â°F to +90Â°F\nRefrigeration\nRefrigeration System\nVCC compressor-based, forced-air hydrocarbon\nCompressor\nHermetic, variable speed (VCC). Rated speed range: 1300-4000 rpm\nCondenser Type\nAir-cooled fin and tube, sealed\nDefrost Method\nAutomatic\nRefrigerant\nR600a, Isobutane, EPA SNAP compliant\nController / Configuration Settings\nUser Interface\ni.C3Â® color touchscreen, door mounted, 7in | 177mm, Â°C or Â°F\nPower Switch\nOn/Off\nController Type\nMicroprocessor with touchscreen input & display\nSecurity\nLockable doors, password protected settings\nControl Sensor\nRTD, stainless steel\niPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456 Vaccine Storage Certified Labeling and Certificate of Calibration\n\nCommunication Ports\nUSB, Remote alarm contacts, RJ45 (Ethernet). API available for Ethernet connectivity development\nPower Failure Alarm\nYes\nHigh/Low Alarms - Tests\nYes, fully adjustable, automatic (Peltier) testing\nDoor Ajar Alarm\nYes, fully adjustable\nCondenser Temperature Alarm\nYes, fully adjustable\nMin/Max Temperature\nYes, display and reset\nDownload\nYes, via USB. CSV and PDF\nEvent Log\nYes, all alarms, door openings, download via USB\nTemperature Log\nYes, download via USB\nInteractive Temperature Graph\nYes\nTemperature Monitoring Ballast\nYes, two 4 oz bottles with screw caps, solid ballasts optional\nBattery Back-up\nYes, 20 hr. display & alarm back up for i.C3Â® touchscreen | Rechargeable 12V, lead acid\nInterior Storage (w x h x d)\n2 ventilated, powder coated shelves, adjustable\n22.5 x 21.9 in | 572 x 557 mm, 100 lb | 46 kg max capacity/shelf\n12 ventilated, powder coated, pull-out drawers, adjustable\n21.5 x 3.9 x 22 in | 546 x 100 x 560 mm, 100 lb | 46 kg max capacity/drawer\niPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456 Vaccine Storage Certified Labeling and Certificate of Calibration\n\nOptions | Accessories\nStainless steel interior, Chart recorder, Chart paper, Leveling feet, Solid ballast, Remote alarms, Floor and Wall bracket kit, Seismic anchoring kit, Storage trays, Screen protector, Locking drawer, Solid or heated glass doors, Top cover, Side-wall access ports, Temperature validation, Validation guide (IQ/OQ), Extended warranty\nCertificate of Calibration\nYes, generated with ISO 17025 certified, NIST traceable thermometer\nWarranty\nRel.i Plus Warranty - 7 years compressor, 2 years parts, 1 year labor\nOutside US and Canada - Contact your distributor for warranty information\n\nThe anticipated NAICS code for this requirement is 333415 Air-Conditioning and warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing with Size Standard of 1,250 employees.\n\nNo set-aside determination has been made at this time. The Government is seeking information to support acquisition planning and any applicable socioeconomic determination.\n\nOnly firms interested and capable should send their information and any questions by email to Cristina.lansangan@va.gov no later than 4:00 PM Pacific Standard Time, August 19, 2026.\n\nPlease provide the following information in your response:\nCompany Name and UEI\nPoint of Contact: Name, Phone Number and E-mail address\nSBA Socio-economic Status\nCapability Statement\nIndicate whether this equipment is available under GSA/FSS/NAC contract, including contract number and expiry date\nAuthorized Distributor Letter (if applicable)\nEstimated Price\n\nDISCLAIMER\n\nThis Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly. The Government will not compensate an offeror for providing information in response to this notice. Furthermore, the Government reserves the right to cancel this requirement at its discretion.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26126Q1003","place_of_performance":{"zip":"1302","city":{"name":"Pasay City"},"street":"Department of Veterans Affairs Manila Outpatient Clinic","country":{"code":"PHL","name":"PHILIPPINES"},"street2":"1501 Roxas Boulevard"},"product_service_code":"4110"}],"due_at":"2026-08-19T23:00:00Z","due_date":"2026-08-19","closes_at":"2026-08-19T23:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"PHL","state_source":null,"state_evidence":"Product purchase (PSC 4110)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-25T01:37:07.956770Z","principal_notice_id":"edf296f080b341baacd1697b4c104a61","description":{"text":"SOURCES SOUGHT NOTICE BRAND NAME OR EQUAL - Helmer iPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft. for VA Manila Outpatient Clinic\n\nThis is a Sources Sought Notice issued solely for information and planning purposes ONLY. It does not constitute a solicitation. Responses to this notice will assist the Government in identifying potential sources capable of providing the required equipment. No reimbursement will be made for any costs associated with providing information in response to this notice.\n\nThe Department of Veterans Affairs, Manila Outpatient Clinic is seeking potential sources capable of providing two (2) units Helmer iPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft, (Brand name or Equal).\n\nThe essential/significant physical, functional or performance characteristics of the requirement are:\n\nApplication, Rating, & Electrical Data\nApplication\nHigh performance storage of medical and scientific products\nStorage Volume\n44.9 cu ft | 1271 L\nTemperature Range\n+2Â°C to +10Â°C\nSet Point\n+5Â°C\nElectrical Power\n115V 60Hz | 220-240V 50-60Hz\nCertification/Agency Listing\nQPS (Certified to UL and CSA Standards)\nIEC/UL61010-2-011: 2016 | IEC 61010-1:2010, AMD1:2016 ETL certified to NSF/ANSI 456 Vaccine Storage Standard\nEnergy Star\nYes, ENERGY STARÂ® Certified High Performance Refrigerator\nAmbient Operating Temperature\n+15Â°C to +32Â°C | +59Â°F to +90Â°F\nRefrigeration\nRefrigeration System\nVCC compressor-based, forced-air hydrocarbon\nCompressor\nHermetic, variable speed (VCC). Rated speed range: 1300-4000 rpm\nCondenser Type\nAir-cooled fin and tube, sealed\nDefrost Method\nAutomatic\nRefrigerant\nR600a, Isobutane, EPA SNAP compliant\nController / Configuration Settings\nUser Interface\ni.C3Â® color touchscreen, door mounted, 7in | 177mm, Â°C or Â°F\nPower Switch\nOn/Off\nController Type\nMicroprocessor with touchscreen input & display\nSecurity\nLockable doors, password protected settings\nControl Sensor\nRTD, stainless steel\niPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456 Vaccine Storage Certified Labeling and Certificate of Calibration\n\nCommunication Ports\nUSB, Remote alarm contacts, RJ45 (Ethernet). API available for Ethernet connectivity development\nPower Failure Alarm\nYes\nHigh/Low Alarms - Tests\nYes, fully adjustable, automatic (Peltier) testing\nDoor Ajar Alarm\nYes, fully adjustable\nCondenser Temperature Alarm\nYes, fully adjustable\nMin/Max Temperature\nYes, display and reset\nDownload\nYes, via USB. CSV and PDF\nEvent Log\nYes, all alarms, door openings, download via USB\nTemperature Log\nYes, download via USB\nInteractive Temperature Graph\nYes\nTemperature Monitoring Ballast\nYes, two 4 oz bottles with screw caps, solid ballasts optional\nBattery Back-up\nYes, 20 hr. display & alarm back up for i.C3Â® touchscreen | Rechargeable 12V, lead acid\nInterior Storage (w x h x d)\n2 ventilated, powder coated shelves, adjustable\n22.5 x 21.9 in | 572 x 557 mm, 100 lb | 46 kg max capacity/shelf\n12 ventilated, powder coated, pull-out drawers, adjustable\n21.5 x 3.9 x 22 in | 546 x 100 x 560 mm, 100 lb | 46 kg max capacity/drawer\niPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456 Vaccine Storage Certified Labeling and Certificate of Calibration\n\nOptions | Accessories\nStainless steel interior, Chart recorder, Chart paper, Leveling feet, Solid ballast, Remote alarms, Floor and Wall bracket kit, Seismic anchoring kit, Storage trays, Screen protector, Locking drawer, Solid or heated glass doors, Top cover, Side-wall access ports, Temperature validation, Validation guide (IQ/OQ), Extended warranty\nCertificate of Calibration\nYes, generated with ISO 17025 certified, NIST traceable thermometer\nWarranty\nRel.i Plus Warranty - 7 years compressor, 2 years parts, 1 year labor\nOutside US and Canada - Contact your distributor for warranty information\n\nThe anticipated NAICS code for this requirement is 333415 Air-Conditioning and warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing with Size Standard of 1,250 employees.\n\nNo set-aside determination has been made at this time. The Government is seeking information to support acquisition planning and any applicable socioeconomic determination.\n\nOnly firms interested and capable should send their information and any questions by email to Cristina.lansangan@va.gov no later than 4:00 PM Pacific Standard Time, August 19, 2026.\n\nPlease provide the following information in your response:\nCompany Name and UEI\nPoint of Contact: Name, Phone Number and E-mail address\nSBA Socio-economic Status\nCapability Statement\nIndicate whether this equipment is available under GSA/FSS/NAC contract, including contract number and expiry date\nAuthorized Distributor Letter (if applicable)\nEstimated Price\n\nDISCLAIMER\n\nThis Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly. The Government will not compensate an offeror for providing information in response to this notice. Furthermore, the Government reserves the right to cancel this requirement at its discretion.","html":"SOURCES SOUGHT NOTICE   BRAND NAME OR EQUAL - Helmer iPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft. for VA Manila Outpatient Clinic \n\nThis is a Sources Sought Notice issued solely for information and planning purposes ONLY. It does not constitute a solicitation. Responses to this notice will assist the Government in identifying potential sources capable of providing the required equipment. No reimbursement will be made for any costs associated with providing information in response to this notice.\n\nThe Department of Veterans Affairs, Manila Outpatient Clinic is seeking potential sources capable of providing two (2) units Helmer iPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft, (Brand name or Equal).\n\nThe essential/significant physical, functional or performance characteristics of the requirement are:\n\nApplication, Rating, & Electrical Data \nApplication \nHigh performance storage of medical and scientific products \nStorage Volume \n44.9 cu ft | 1271 L \nTemperature Range \n+2Â°C to +10Â°C \nSet Point \n+5Â°C \nElectrical Power \n115V 60Hz | 220-240V 50-60Hz \nCertification/Agency Listing \nQPS (Certified to UL and CSA Standards) \nIEC/UL61010-2-011: 2016 | IEC 61010-1:2010, AMD1:2016 ETL certified to NSF/ANSI 456 Vaccine Storage Standard \nEnergy Star \nYes, ENERGY STARÂ® Certified High Performance Refrigerator \nAmbient Operating Temperature \n+15Â°C to +32Â°C | +59Â°F to +90Â°F \nRefrigeration \nRefrigeration System \nVCC compressor-based, forced-air hydrocarbon \nCompressor \nHermetic, variable speed (VCC). Rated speed range: 1300-4000 rpm \nCondenser Type \nAir-cooled fin and tube, sealed \nDefrost Method \nAutomatic \nRefrigerant \nR600a, Isobutane, EPA SNAP compliant \nController / Configuration Settings \nUser Interface \ni.C3Â® color touchscreen, door mounted, 7in | 177mm, Â°C or Â°F \nPower Switch \nOn/Off \nController Type \nMicroprocessor with touchscreen input & display \nSecurity \nLockable doors, password protected settings \nControl Sensor \nRTD, stainless steel \niPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456 Vaccine Storage Certified Labeling and Certificate of Calibration\n\nCommunication Ports \nUSB, Remote alarm contacts, RJ45 (Ethernet). API available for Ethernet connectivity development \nPower Failure Alarm \nYes \nHigh/Low Alarms - Tests \nYes, fully adjustable, automatic (Peltier) testing \nDoor Ajar Alarm \nYes, fully adjustable \nCondenser Temperature Alarm \nYes, fully adjustable \nMin/Max Temperature \nYes, display and reset \nDownload \nYes, via USB. CSV and PDF \nEvent Log \nYes, all alarms, door openings, download via USB \nTemperature Log \nYes, download via USB \nInteractive Temperature Graph \nYes \nTemperature Monitoring Ballast \nYes, two 4 oz bottles with screw caps, solid ballasts optional \nBattery Back-up \nYes, 20 hr. display & alarm back up for i.C3Â® touchscreen | Rechargeable 12V, lead acid \nInterior Storage (w x h x d) \n2 ventilated, powder coated shelves, adjustable \n22.5 x 21.9 in | 572 x 557 mm, 100 lb | 46 kg max capacity/shelf \n12 ventilated, powder coated, pull-out drawers, adjustable \n21.5 x 3.9 x 22 in | 546 x 100 x 560 mm, 100 lb | 46 kg max capacity/drawer \niPR245-GX i.SeriesÂ® Pharmacy Refrigerator, 44.9 cu ft (1271 Liters) (with NSF/ANSI 456  Vaccine Storage Certified Labeling and Certificate of Calibration\n\nOptions | Accessories \nStainless steel interior, Chart recorder, Chart paper, Leveling feet, Solid ballast, Remote alarms, Floor and Wall bracket kit, Seismic anchoring kit, Storage trays, Screen protector, Locking drawer, Solid or heated glass doors, Top cover, Side-wall access ports, Temperature validation, Validation guide (IQ/OQ), Extended warranty \nCertificate of Calibration \nYes, generated with ISO 17025 certified, NIST traceable thermometer \nWarranty \nRel.i  Plus Warranty - 7 years compressor, 2 years parts, 1 year labor \nOutside US and Canada - Contact your distributor for warranty information \n\nThe anticipated NAICS code for this requirement is 333415   Air-Conditioning and warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing with Size Standard of 1,250 employees. \n\nNo set-aside determination has been made at this time. The Government is seeking information to support acquisition planning and any applicable socioeconomic determination.\n\nOnly firms interested and capable should send their information and any questions by email to Cristina.lansangan@va.gov no later than 4:00 PM Pacific Standard Time, August 19, 2026.\n\nPlease provide the following information in your response:\nCompany Name and UEI\nPoint of Contact: Name, Phone Number and E-mail address\nSBA Socio-economic Status \nCapability Statement\nIndicate whether this equipment is available under GSA/FSS/NAC contract, including contract number and expiry date \nAuthorized Distributor Letter (if applicable)\nEstimated Price\n\n\nDISCLAIMER\n\nThis Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly. The Government will not compensate an offeror for providing information in response to this notice. Furthermore, the Government reserves the right to cancel this requirement at its discretion.","origin":"detail"},"contacts":[{"name":"Cristina Mae Lansangan","role":"primary","email":"cristina.lansangan@va.gov","phone":"011-632-833-4566","title":"Contracting Officer"}],"place_of_performance":{"zip":"1302","city":{"name":"Pasay City"},"street":"Department of Veterans Affairs Manila Outpatient Clinic","country":{"code":"PHL","name":"PHILIPPINES"},"street2":"1501 Roxas Boulevard"},"office_address":{"zip":"95655","city":"MATHER","state":"CA","country":"USA"},"naics_codes":["333415"],"award":{"awardee":{}},"attachments":[{"resource_id":"c503ed7001fa43d2af902831338741d5","name":"36C26126Q1003.docx","kind":"file","mime_type":".docx","size_bytes":19942,"posted_at":"2026-08-13T23:14:52.623Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c503ed7001fa43d2af902831338741d5/download","mirrored":false}],"awards":[],"related":[{"key":"36C26126Q1297","latest_notice_id":"a62af13fb8674f5c9add72a5c2417296","title":"Z2DA--654-24-004 | Remediate Old Parking Garage","solicitation_number":"36C26126Q1297","notice_type":"o","first_type":"r","first_posted":"2026-09-29","last_posted":"2026-11-18","notices":9,"due_at":"2026-11-25T23:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","state":"NV","county":"32031","county_name":"Washoe County","city":"3260600","city_name":"Reno","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26127Q0175","latest_notice_id":"6ff0b83d55464667808667710e947d25","title":"N099--Install ID Storage Shed Project Number 593-27-307 North Las Vegas, NV","solicitation_number":"36C26127Q0175","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T20:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"236220","psc":"N099","set_aside":null,"state":"NV","county":"32003","county_name":"Clark County","city":"3251800","city_name":"North Las Vegas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26127Q0169","latest_notice_id":"9989888cf8614c8e87f9894ee00a31e7","title":"J012--Dry-Type Fire Suppression System","solicitation_number":"36C26127Q0169","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-30T23:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"811310","psc":"J012","set_aside":null,"state":"CA","county":"06085","county_name":"Santa Clara County","city":"0655282","city_name":"Palo Alto","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26127Q0167","latest_notice_id":"28c31f3c4e3541cfa45f402ef2a11308","title":"7310--TRANSPORT CART AND SERVING TRAY_ Nutrition & Food Service","solicitation_number":"36C26127Q0167","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-30T23:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T23:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"333241","psc":"7310","set_aside":null,"state":"CA","county":"06085","county_name":"Santa Clara County","city":"0655282","city_name":"Palo Alto","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C26127Q0082","latest_notice_id":"1a5811f6c2cb4c5d887f8b4b9ad3c664","title":"Z1DZ--Project No. 640A0-27-104, Replace Roof at Building 347 - Menlo Park","solicitation_number":"36C26127Q0082","notice_type":"k","first_type":"k","first_posted":"2026-10-20","last_posted":"2026-11-12","notices":3,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C261","office_name":"261-NETWORK CONTRACT OFFICE 21 (36C261)","naics":"236220","psc":"Z1DZ","set_aside":"SDVOSBC","state":"CA","county":"06081","county_name":"San Mateo County","city":"0646870","city_name":"Menlo Park","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"}],"similar_open":[{"key":"SPE8E727Q0025","latest_notice_id":"07ecc6eda9bd4fe4a295f2e8bb730c13","title":"41--POWER,BREEZER","solicitation_number":"SPE8E727Q0025","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE8E7","office_name":"DLA TROOP SUPPORT","naics":"333415","psc":"41","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"EEZER: LINE 0001 QTY 2 UI EA DELIVER TO: 0060 AD BTY BTY F ADA BATTE BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"SPE8E827Q0072","latest_notice_id":"02bc9475908a4301982e74978b5029dc","title":"41--FILTER ELEMENT,AIR CON","solicitation_number":"SPE8E827Q0072","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE8E8","office_name":"DLA TROOP SUPPORT","naics":"333415","psc":"41","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"CON: LINE 0001 QTY 4000 UI EA DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"SPE8E827Q0071","latest_notice_id":"08b7700c96b0442a85d5459c456523f6","title":"41--FILTER ELEMENT,AIR CON","solicitation_number":"SPE8E827Q0071","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":null,"due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE8E8","office_name":"DLA TROOP SUPPORT","naics":"333415","psc":"41","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"CON: LINE 0001 QTY 124 UI EA DELIVER TO: W1A8 DLA DIST SAN JOAQUIN BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":25,"indexable":false}