Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,557 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought, service-disabled veteran-owned small business set-aside

Fire Alarm Maintenance for VA Palo Alto Health Care System

36C26126Q0022

Department of Veterans Affairs, 261-Network Contract Office 21. Security Systems Services (except Locksmiths).

Response deadline

August 15, 2025 at 2:00 PM EDT

Closed 467 days ago. Posted August 11, 2025. Scheduled to archive August 25, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

27 like it are open now in security systems services (except locksmiths)

All 27 open in security systems services (except locksmiths)

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
Service-disabled veteran-owned small business set-aside. Reserved for service-disabled veteran-owned small businesses. Small, under NAICS 561621 (security systems services (except locksmiths)), means no more than $25 million in average annual receipts, counted with affiliates. Open SDVOSB opportunities
What comes next
No solicitation was published under this number after the sources sought of August 11, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY.    No Solicitation is currently available.    All information contained in this Sources Sought Announcement is preliminary, as well as subject to modification, and is in no way binding on the Government.  The Government will not pay for any information submitted in response to this request.  The information requested will be used solely within the Department of Veterans Affairs to facilitate decision making and will not be disclosed outside of the Government.  The determination of a procurement strategy, based upon the comments submitted in response to this Sources Sought Announcement, is solely within the discretion of the Government.    The applicable North American Industry Classification System (NAICS) Code is 561621, Security Systems Services (except Locksmiths), size standard is $25M.   Potential Offerors must be registered in the System for Award Management (SAM) to be eligible for an award (See Internet Site https://www.sam.gov/portal/public/SAM/).  Potential Offerors must also have a current Online Representations and Certification Application on file with SAM.  DESCRIPTION OF WORK  1.  General:   The Contractor shall furnish all labor, tools, material, parts necessary to provide testing, maintenance and repair/correction of fire alarms and suppression systems at the Palo Alto, Menlo Park, and Livermore Divisions, including VA in Mountain View, all VA Residential and Transition Home units in Menlo Park inspection and testing only of fire protection systems at the facilities in accordance with National Fire Protection Association (NFPA) 101 Life Safety Code , NFPA-72 National Fire Alarm Code , NFPA- 99 Health Care Facilities , and NFPA-25, Standard for Inspection, Testing and Maintenance of Water-based Fire Protection Systems and The Joint Commission accreditation standards for hospitals. The total number of devices is approximately 12,000.   2. Description of Services: The Contractor shall be required to provide a 24-hour/7 days per week emergency service coverage with a maximum on-site response time of 4 hours. Additionally, the Contractor shall provide unlimited service(repair) calls. If technical personnel do not answer the Contractor s telephones, a technical maintenance representative shall respond by telephone to the COR or designated representative within one hour of a service call from the COR or designated representative. The COR shall provide a list of individuals authorized to make calls for service   The Government requests that interested parties provide the following capability information to the Contract Specialist, Jill Williams by e-mail at jill.williams@va.gov by 11:00am PST 08/15/2025:  (a) Business Size (Large/Small)  (b) Business Socio-Economic Status (SDVOSB, WOSB, 8(a), HUBZone, etc.)  (c) SAM record  (d) Ability and experience with similar projects.   The Government will use this information when determining its business type decision.    This Sources Sought is not to be construed as a commitment by the Government and no contract will be awarded as a direct result of this Sources Sought announcement.  Â

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. August 11, 2025

    Sources sought

    Due August 15, 2025 at 2:00 PM EDT. SAM.gov, notice 8aac4cc6740249959606167c6d80cd54

    1 revision on SAM
    • August 11, 2025: publish, sources sought

Points of contact