Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,699 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $99 a month. See your matches before you pay.
See plans

Sources sought

Thyroid Uptake System

36C26026Q0928

Department of Veterans Affairs, 260-Network Contract Office 20. Analytical Laboratory Instrument Manufacturing.

Response deadline

August 13, 2026 at 5:00 PM EDT

Closed 104 days ago. Posted August 6, 2026. Scheduled to archive August 28, 2026.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2026

61 like it are open now in analytical laboratory instrument manufacturing

All 61 open in analytical laboratory instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation has been published under this number yet. The sources sought of August 6, 2026 is the earliest notice of the purchase.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

SOURCES SOUGHT NOTICE THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL OR QUOTE; THE VA IS NOT SEEKING PRICING OR OFFERS. The Department of Veterans Affairs, VISN 20, in support of the Mann-Grandstaff VA Medical Center, is performing market research to compile data regarding: (1) The availability and capability of qualified small business concerns; (2) Identify if there are sufficient number of qualified Service-Disabled Veteran-Owned Small Business, Veteran Owned Small Business, HUB Zone 8(a), Women-Owned Small Business, or Small Disadvantaged Business, Small Business concerns relative to the subject North American Industry Classification System (NAICS) code. Responses to the information requested will assist the Government in determining the appropriate procurement method, including any set-aside decision. Respondents should clearly describe their capabilities to include management experience, equipment and personnel or the ability to obtain them. Furthermore, interested sources must also meet all requirements of Federal, State, and Local Municipal codes regarding operations of this type of service. The NAICS code assigned is: 334516 Analytical Laboratory Instrument Manufacturing The small business size standard is 1,000 employees. Not responding to this Sources Sought does not preclude participation in any future or potential solicitation, or Request for Quotation. It is the intent of the Mann-Grandstaff VA Medical Center to use the information gathered for market research purposes only. If a formal solicitation is released, it will be posted via the Contract Opportunies on Sam.gov. DESCRIPTION OF THE REQUIREMENT: The Department of Veterans Affairs, Network Contracting Office 20, is seeking sources that can provide a Captus 4000e or equal thyroid uptake system. Equal product will be considered if it has the same characteristics as listed below: 1. General System Functionality Must be a comprehensive nuclear medicine measurement system capable of performing thyroid uptake measurements, wipe tests, bioassay measurements, and automated quality assurance functions. Must include a software-driven workflow that supports predefined protocols and customizable measurement sequences. 2. User Interface & Computer Requirements Must utilize a color touch screen user interface with a large-format display (minimum 20 inches for visibility during procedures). Must operate on a current, widely supported Windows OS platform. (VA current platform Windows 10 or 11) Must support generation of reports containing graphics, isotope spectra, and archived data, with ability to save or print reports in PDF format. 3. Detector & Measurement Specifications Thyroid Uptake Detector Must utilize a NaI(Tl) scintillation detector capable of precise uptake measurements. (Spec: 2 inch diameter NaI(Tl).) Must include a collimator meeting recognized nuclear medicine performance standards (e.g., ANSI or IAEA). Must include a physical measurement/alignment mechanism to ensure consistent detector to thyroid distance. Multichannel Analyzer (MCA) Must include an MCA with a minimum of 1024 channels. Must provide automated and manual calibration capabilities. Must support user defined and preset ROIs, live time, real time, and total count presets. Must support accurate count rate linearity ( 2% deviation up to at least 150,000 cps). Optional Well Counter Must support well counting for capsule/liquid dose formats utilizing a NaI(Tl) well detector. (Spec: 2 inch diameter NaI(Tl).) Must provide shielding sufficient for radiation safety and measurement accuracy (minimum 1 inch lead shielding). 4. Quality Assurance Capabilities Must provide fully automated QA tests including energy calibration, zero adjust, gain adjust, detector efficiency, resolution, chi square, constancy, and minimum detectable activity (MDA). Must include both automated and manual calibration options. 5. Thyroid Uptake Measurement Requirements Must support capsule and liquid dose formats. Must allow pre-dose and pre count measurement. Must include multiple predefined thyroid uptake protocols and allow custom protocol creation. 6. Wipe Test & Bioassay Capabilities Must support multi group wipe test setup and isotope identification with spectral display. Must flag wipe test results exceeding trigger levels. Must support bioassay monitoring for common isotopes (e.g., I 123, I 125, I 131). Must allow user defined action levels and produce individual and summary reports. 7. Connectivity / System Integration Requirements Must provide optional or integrated DICOM capability that can retrieve patient data and upload reports to hospital information systems. 8. Physical / Form Factor Requirements Must include a mobile, ergonomic stand with adjustable height and articulating detector arm capable of wide range motion (vertical travel and rotation). Must include secure storage for neck phantom and quality control sources. Must include cable management to maintain safe, clinical grade setup. Must include hospital-grade power configuration with isolation transformer. 9. Reporting & Data Archival Requirements Must allow reporting that includes full spectrum graphics and thyroid uptake time vs value graphs. Must permit archiving of measurement data and export in standard formats. The information above is intended to be descriptive, not restrictive, to indicate the quality of equipment that will be satisfactory. It is the responsibility of the interested source to demonstrate to the Government that the interested source can provide equipment that fulfills the required specifications. POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE: Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program: [ ] yes [ ] no - Small Business (SB) [ ] yes [ ] no - HUBZone [ ] yes [ ] no - Small Business 8(a) [ ] yes [ ] no - Small Disadvantaged Business (SDB) [ ] yes [ ] no - Women-Owned (WO) Small Business [ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB) [ ] yes [ ] no - Veteran Owned Small Business (VOSB) [ ] yes [ ] no - Large Business [ ] yes [ ] no - Other (please specify) [ ] yes [ ] no Are you the Original Equipment Manufacturer (OEM)? [ ] yes [ ] no If not the OEM, are you an authorized distributor, and can produce a letter from the OEM? [ ] yes [ ] no Is this product available on your GSA/FSS or other GWAC Contract? If so, what is your contract number?_____________________ [ ] yes [ ] no Does your equipment conform to the Buy American Act and RFO 52.225-1? 52.225-1 Buy American-Supplies | Acquisition.GOV What is the estimated Delivery Date After Receipt of Order (ARO)? _____________ Please include the following information: Company Name: POC: UEI: Address: Email: In addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, experience etc.) to confirm the company s ability to meet the requirements outlined in this request. Disclaimer: This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. After reviewing the responses received, a pre-solicitation synopsis and solicitation may be published in Contract Opportunities (https://sam.gov/). Submit Capability Statements to: Department of Veterans Affairs, VISN 20 Attn: Krystal Weeks, no later than 2:00 PM (PDT), August 13, 2026. Responses must be submitted via e-mail to: krystal.weeks@va.gov and nco20supplyteam2@va.gov . Note: Do not include Proprietary, classified, confidential, or sensitive information in responses.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. August 6, 2026

    Sources sought

    Due August 13, 2026 at 5:00 PM EDT. SAM.gov, notice 50ba2fc1a0f34a808cb420aebcbe3aa7

    1 revision on SAM
    • August 6, 2026: publish, sources sought

Points of contact