{"canonical":"https://sealedbidder.com/opportunities/36c26026q0844","key":"36C26026Q0844","url":"https://sealedbidder.com/opportunities/36c26026q0844","title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","solicitation_number":"36C26026Q0844","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-21T17:00:00Z","first_posted":"2026-07-14","last_posted":"2026-07-14","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"334516","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"405e2bd7e95f4bd99591053181118b2d","title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","solicitation_number":"36C26026Q0844","notice_type":"r","base_type":"r","posted":"2026-07-14","posted_at":"2026-07-14T23:19:38.109Z","due_at":"2026-07-21T17:00:00Z","due_date":"2026-07-21","cancelled":false,"archived":true,"archive_date":"2026-08-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/405e2bd7e95f4bd99591053181118b2d/view","enriched":true,"history":[{"index":6,"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T23:25:32.067Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9928500653c04ce99d69cc8530235ca2","solicitation_number":"36C26026Q0844","related_opportunity_id":"405e2bd7e95f4bd99591053181118b2d"},{"index":4,"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T23:19:38.109Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"405e2bd7e95f4bd99591053181118b2d","solicitation_number":"36C26026Q0844"}]},{"notice_id":"9928500653c04ce99d69cc8530235ca2","title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","solicitation_number":"36C26026Q0844","notice_type":"o","base_type":"r","posted":"2026-07-14","posted_at":"2026-07-14T23:25:32.067Z","due_at":"2026-07-21T17:00:00Z","due_date":"2026-07-21","cancelled":false,"archived":true,"archive_date":"2026-08-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9928500653c04ce99d69cc8530235ca2/view","enriched":true,"history":[{"index":6,"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T23:25:32.067Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9928500653c04ce99d69cc8530235ca2","solicitation_number":"36C26026Q0844","related_opportunity_id":"405e2bd7e95f4bd99591053181118b2d"},{"index":4,"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T23:19:38.109Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"405e2bd7e95f4bd99591053181118b2d","solicitation_number":"36C26026Q0844"}]}],"latest_notice_id":"9928500653c04ce99d69cc8530235ca2","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-07-14","posted_at":"2026-07-14T23:19:38.109Z","created_at":"2026-07-14T23:19:35.886Z","modified_at":"2026-08-05T05:06:25.107Z","response_deadline":{"raw":"2026-07-21T10:00:00-07:00","utc":"2026-07-21T17:00:00Z","date":"2026-07-21","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/405e2bd7e95f4bd99591053181118b2d/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","agency":{"office":{"code":"36C260","name":"260-NETWORK CONTRACT OFFICE 20 (36C260)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"organization_id":"100186526","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-05","archive_type":"auto_custom"},"history":[{"index":6,"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T23:25:32.067Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9928500653c04ce99d69cc8530235ca2","solicitation_number":"36C26026Q0844","related_opportunity_id":"405e2bd7e95f4bd99591053181118b2d"},{"index":4,"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T23:19:38.109Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"405e2bd7e95f4bd99591053181118b2d","solicitation_number":"36C26026Q0844"}],"contacts":[{"name":"Hector Gonzalez","role":"primary","email":"hector.gonzalez1@va.gov","title":"Contracting Specialists"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"405e2bd7e95f4bd99591053181118b2d","lineage_id":"405e2bd7e95f4bd99591053181118b2d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T03:27:20.065414922Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"7c6b1cad0e361df0e603862bdcab23b58b80b298dd93e351f18777f465c11c26","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T03:27:20.065414922Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"Walla Walla VA medical Center is looking to purchase a Molecular PCR Analyzer for the Detection of Pathogen s related to Women s Health and Sexual Health. \nTest Collection Requirements:\n\nSpecimen collection kits must be available for the following samples and FDA approved for patient self-collection in a clinical setting:\nEndocervical\nVaginal\nPharyngeal\nRectal\nUrine\nAnalyzer must be capable of performing qualitative PCR tests on self-collected samples for detection and differentiation of these DNA targets with testing multiplexed efficiently to include all analytes in the least amount of test panels.","text":"Walla Walla VA medical Center is looking to purchase a Molecular PCR Analyzer for the Detection of Pathogen s related to Women s Health and Sexual Health.\nTest Collection Requirements:\n\nSpecimen collection kits must be available for the following samples and FDA approved for patient self-collection in a clinical setting:\nEndocervical\nVaginal\nPharyngeal\nRectal\nUrine\nAnalyzer must be capable of performing qualitative PCR tests on self-collected samples for detection and differentiation of these DNA targets with testing multiplexed efficiently to include all analytes in the least amount of test panels.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26026Q0844","place_of_performance":{"zip":"99362","city":{"name":"Walla Walla"},"state":{"name":"WA"},"street":"US Department of Veterans Affairs Walla Walla VAMCC","street2":"77 Wainwright Drive"},"product_service_code":"6515"},{"award":{"awardee":{}},"dates":{"posted":"2026-07-14","posted_at":"2026-07-14T23:25:32.067Z","created_at":"2026-07-14T23:25:29.887Z","modified_at":"2026-08-05T05:06:25.107Z","response_deadline":{"raw":"2026-07-21T10:00:00-07:00","utc":"2026-07-21T17:00:00Z","date":"2026-07-21","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9928500653c04ce99d69cc8530235ca2/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","agency":{"office":{"code":"36C260","name":"260-NETWORK CONTRACT OFFICE 20 (36C260)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"organization_id":"100186526","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-05","archive_type":"auto_custom"},"history":[{"index":6,"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T23:25:32.067Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9928500653c04ce99d69cc8530235ca2","solicitation_number":"36C26026Q0844","related_opportunity_id":"405e2bd7e95f4bd99591053181118b2d"},{"index":4,"title":"6515--Purchase of a Molecular PCR Analyzer for Detection of Pathogen's related to Women's Health and Sexual Health","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-14T23:19:38.109Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"405e2bd7e95f4bd99591053181118b2d","solicitation_number":"36C26026Q0844"}],"contacts":[{"name":"Hector D Gonzalez","role":"primary","email":"hector.gonzalez1@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"9928500653c04ce99d69cc8530235ca2","lineage_id":"405e2bd7e95f4bd99591053181118b2d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T03:41:36.265769636Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"69bf1f4f947dc10bdd3d58af2c0c12f135f969013192c176b78a50a904378df0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T03:41:36.265769636Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"The Department of Veterans Affairs (VA), Network Contracting Office 20 (NCO 20), is conducting market research on behalf of the Jonathan M. Wainwright Memorial VA Medical Center to identify potential contractors capable of providing reagents and consumables for laboratory tests for the VA medical facilities and clinics.    \nThe Jonathan M. Wainwright Memorial VA Medical Center is comprised of: \n\nJonathan M. Wainwright Memorial VA Medical Center.\nLa Grande VA Clinic.\nLewiston VA Clinic.\nMorrow County VA Clinic.\nRichland VA Clinic\nYakima Valley VA Clinic\n\nTo be considered a responsive and potential source, interested parties shall provide a capabilities statement containing the following information:\nBusiness name, address, point of contact, phone number and email address.\nBusiness size, type, and SAM Unique Identifier Number\nAffirmation that the vendor can provide the supplies in accordance with the attached Salient Characteristics.\n\nAdditionally, contractors can provide feedback on the attached Requirements Description, which may be considered if a solicitation is posted.  \nProvide the requested information to Hector Gonzalez at hector.gonzalez1@va.gov before 10:00 AM PST on July 21st, 2026.  All questions must be submitted in writing, no telephonic inquiries will be accepted.  \n\nThis is a sources-sought notice only. The purpose of this notice is to obtain information regarding the availability and capability of verified sources to include qualified SDVOSB/VOSB to perform this potential requirement. Responses received will assist the Government in determining the appropriate acquisition strategy. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time, and this is not a request for quotes.\n\n\n\n\n\n\nSalient Characteristics\nMolecular PCR Analyzer for Detection of Pathogen s related to\nWomen s Health and Sexual Health\n\nOverview:\n\nThe Women s Health Innovation and Staffing Enhancements (WHISE) initiative awarded funding to the Jonathan M. Wainwright Memorial VA Medical Center (VAWW) Laboratory to support implementation of in-house molecular testing capability during Fiscal Year 2026 for prompt detection and reporting of pathogens related to veteran women s health and sexual health.  \n\nScope Required for Women s Health and Sexual Health Testing:\n\nThe analyzer must allow for rapid in-house molecular testing with significantly improved turnaround times of 1.0 -1.5 hours (or less) for women s health and sexual health to support same-day diagnosis and treatment workflows when clinically appropriate. Must have the ability to perform Multiplex Vaginal Panel and Chlamydia trachomatis/Neisseria gonorrhoeae on a single platform (instrument) simultaneously.  These two panels include:\nMultiplex Vaginal Panel (results in 60 minutes or less)\nBacterial vaginosis\nAtopobium spp.\nBacterial Vaginosis-Associated Bacterium (BVAB2)\nMegasphaera-1\nCandida spp. (C. albicans, C. tropicalis, C. parapsilosis, C. dubliniensis\nCandida glabrata/Candida krusei\nTrichomonas vaginalis\nCT/NG Panel (results in 90 minutes or less) for both males and females.  Cartridge must also include sample adequacy controls to confirm the presence of human DNA.\nChlamydia trachomatis (CT) - both males and females\nNeisseria gonorrhoeae (NG)   two independent targets required for accuracy\n\nTest Collection Requirements:\n\nSpecimen collection kits must be available for the following samples and FDA approved for patient self-collection in a clinical setting:\nEndocervical\nVaginal\nPharyngeal\nRectal\nUrine\nAnalyzer must be capable of performing qualitative PCR tests on self-collected samples for detection and differentiation of these DNA targets with testing multiplexed efficiently to include all analytes in the least amount of test panels.  \n\nScope Required for Additional Testing:\n\nCompatibility with future decentralized and waived molecular testing workflows within the same manufacturer ecosystem represents a significant operational advantage for future outpatient and CBOC expansion strategies. Ability to consolidate all the laboratory molecular testing workflows onto one integrated platform will improve, turnaround times, operational standardization, continuity of operations, staffing efficiency, and future scalability.\n\nTherefore, the requested platform must support broader rapid molecular diagnostic testing needs including:\nCOVID-19;\ncombined COVID-19/Influenza A/B/RSV testing;\nFDA-cleared asymptomatic COVID-19 testing;\nMRSA;\nGroup A Streptococcus (Strep A);\nInfluenza A/B;\nRSV;\nand additional molecular diagnostic assays.\n\nFast Turn Around Times (TAT) vs. High Throughput:\n\nAs an ambulatory care facility, the emphasis is on quick result turnaround times and not high throughput.  This instrumentation must provide prompt results (within 1.5 hours) for same day diagnosis and treatment.  Analyzers designed for high throughput such as those used in reference laboratories do not meet the turnaround time requirements as they process large amounts of specimens at once but take longer overall to produce test results (3 to 4 hours). \n\nSpecifications:\n\nOptimized workflow with multi-test capacity.\nMust have the ability to run a minimum of 16 test modules simultaneously.\nMust be able to run multiple assay types and test for multiple diseases at the same time using individual cartridges.\nWorkflow simplicity and minimal hands-on time that utilize efficient user guided software with touchscreen and barcode reader.   \nPre analytical workflows suited for CBOC and outpatient transport demands.\nFast throughput with test results within 1   1.5 hours.\nRequires on demand random access to allow real time testing (not batches).\nTest cartridges:\nMust be closed configuration to reduce the risk of contamination with all steps of PCR testing occurring within the cartridge (extraction, amplification and detection.\nMust include internal controls to monitor/confirm PCR reaction and verify reagent integrity.\nCT/NG Panel cartridge must also include:\n Sample Adequacy Control to confirm the presence of human DNA.\nTwo independent targets required for accuracy\nFDA approved and validated for self-collected samples.\nOn board quality controls to determine run accuracy, probe function and sample adequacy.   \nStability at room temperature for reagents that require significant space.\nInstrument must be able to bidirectionally interface with an LIS.\nUPS backup storage.\nPrinter\nInstrument must be benchtop with compact design with dimensions adequate for countertop space and weight limitations:\n21  width x 26  height x 14  depth\nLess than 175 lbs.\nInstallation included in quote.\nOne year service agreement included in quote and 24/7 technical support","text":"The Department of Veterans Affairs (VA), Network Contracting Office 20 (NCO 20), is conducting market research on behalf of the Jonathan M. Wainwright Memorial VA Medical Center to identify potential contractors capable of providing reagents and consumables for laboratory tests for the VA medical facilities and clinics.\nThe Jonathan M. Wainwright Memorial VA Medical Center is comprised of:\n\nJonathan M. Wainwright Memorial VA Medical Center.\nLa Grande VA Clinic.\nLewiston VA Clinic.\nMorrow County VA Clinic.\nRichland VA Clinic\nYakima Valley VA Clinic\n\nTo be considered a responsive and potential source, interested parties shall provide a capabilities statement containing the following information:\nBusiness name, address, point of contact, phone number and email address.\nBusiness size, type, and SAM Unique Identifier Number\nAffirmation that the vendor can provide the supplies in accordance with the attached Salient Characteristics.\n\nAdditionally, contractors can provide feedback on the attached Requirements Description, which may be considered if a solicitation is posted.\nProvide the requested information to Hector Gonzalez at hector.gonzalez1@va.gov before 10:00 AM PST on July 21st, 2026. All questions must be submitted in writing, no telephonic inquiries will be accepted.\n\nThis is a sources-sought notice only. The purpose of this notice is to obtain information regarding the availability and capability of verified sources to include qualified SDVOSB/VOSB to perform this potential requirement. Responses received will assist the Government in determining the appropriate acquisition strategy. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time, and this is not a request for quotes.\n\nSalient Characteristics\nMolecular PCR Analyzer for Detection of Pathogen s related to\nWomen s Health and Sexual Health\n\nOverview:\n\nThe Women s Health Innovation and Staffing Enhancements (WHISE) initiative awarded funding to the Jonathan M. Wainwright Memorial VA Medical Center (VAWW) Laboratory to support implementation of in-house molecular testing capability during Fiscal Year 2026 for prompt detection and reporting of pathogens related to veteran women s health and sexual health.\n\nScope Required for Women s Health and Sexual Health Testing:\n\nThe analyzer must allow for rapid in-house molecular testing with significantly improved turnaround times of 1.0 -1.5 hours (or less) for women s health and sexual health to support same-day diagnosis and treatment workflows when clinically appropriate. Must have the ability to perform Multiplex Vaginal Panel and Chlamydia trachomatis/Neisseria gonorrhoeae on a single platform (instrument) simultaneously. These two panels include:\nMultiplex Vaginal Panel (results in 60 minutes or less)\nBacterial vaginosis\nAtopobium spp.\nBacterial Vaginosis-Associated Bacterium (BVAB2)\nMegasphaera-1\nCandida spp. (C. albicans, C. tropicalis, C. parapsilosis, C. dubliniensis\nCandida glabrata/Candida krusei\nTrichomonas vaginalis\nCT/NG Panel (results in 90 minutes or less) for both males and females. Cartridge must also include sample adequacy controls to confirm the presence of human DNA.\nChlamydia trachomatis (CT) - both males and females\nNeisseria gonorrhoeae (NG) two independent targets required for accuracy\n\nTest Collection Requirements:\n\nSpecimen collection kits must be available for the following samples and FDA approved for patient self-collection in a clinical setting:\nEndocervical\nVaginal\nPharyngeal\nRectal\nUrine\nAnalyzer must be capable of performing qualitative PCR tests on self-collected samples for detection and differentiation of these DNA targets with testing multiplexed efficiently to include all analytes in the least amount of test panels.\n\nScope Required for Additional Testing:\n\nCompatibility with future decentralized and waived molecular testing workflows within the same manufacturer ecosystem represents a significant operational advantage for future outpatient and CBOC expansion strategies. Ability to consolidate all the laboratory molecular testing workflows onto one integrated platform will improve, turnaround times, operational standardization, continuity of operations, staffing efficiency, and future scalability.\n\nTherefore, the requested platform must support broader rapid molecular diagnostic testing needs including:\nCOVID-19;\ncombined COVID-19/Influenza A/B/RSV testing;\nFDA-cleared asymptomatic COVID-19 testing;\nMRSA;\nGroup A Streptococcus (Strep A);\nInfluenza A/B;\nRSV;\nand additional molecular diagnostic assays.\n\nFast Turn Around Times (TAT) vs. High Throughput:\n\nAs an ambulatory care facility, the emphasis is on quick result turnaround times and not high throughput. This instrumentation must provide prompt results (within 1.5 hours) for same day diagnosis and treatment. Analyzers designed for high throughput such as those used in reference laboratories do not meet the turnaround time requirements as they process large amounts of specimens at once but take longer overall to produce test results (3 to 4 hours).\n\nSpecifications:\n\nOptimized workflow with multi-test capacity.\nMust have the ability to run a minimum of 16 test modules simultaneously.\nMust be able to run multiple assay types and test for multiple diseases at the same time using individual cartridges.\nWorkflow simplicity and minimal hands-on time that utilize efficient user guided software with touchscreen and barcode reader.\nPre analytical workflows suited for CBOC and outpatient transport demands.\nFast throughput with test results within 1 1.5 hours.\nRequires on demand random access to allow real time testing (not batches).\nTest cartridges:\nMust be closed configuration to reduce the risk of contamination with all steps of PCR testing occurring within the cartridge (extraction, amplification and detection.\nMust include internal controls to monitor/confirm PCR reaction and verify reagent integrity.\nCT/NG Panel cartridge must also include:\nSample Adequacy Control to confirm the presence of human DNA.\nTwo independent targets required for accuracy\nFDA approved and validated for self-collected samples.\nOn board quality controls to determine run accuracy, probe function and sample adequacy.\nStability at room temperature for reagents that require significant space.\nInstrument must be able to bidirectionally interface with an LIS.\nUPS backup storage.\nPrinter\nInstrument must be benchtop with compact design with dimensions adequate for countertop space and weight limitations:\n21 width x 26 height x 14 depth\nLess than 175 lbs.\nInstallation included in quote.\nOne year service agreement included in quote and 24/7 technical support","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C26026Q0844","product_service_code":"6515"}],"due_at":"2026-07-21T17:00:00Z","due_date":"2026-07-21","closes_at":"2026-07-21T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-09-29T03:58:53.462888Z","principal_notice_id":"9928500653c04ce99d69cc8530235ca2","description":{"text":"The Department of Veterans Affairs (VA), Network Contracting Office 20 (NCO 20), is conducting market research on behalf of the Jonathan M. Wainwright Memorial VA Medical Center to identify potential contractors capable of providing reagents and consumables for laboratory tests for the VA medical facilities and clinics.\nThe Jonathan M. Wainwright Memorial VA Medical Center is comprised of:\n\nJonathan M. Wainwright Memorial VA Medical Center.\nLa Grande VA Clinic.\nLewiston VA Clinic.\nMorrow County VA Clinic.\nRichland VA Clinic\nYakima Valley VA Clinic\n\nTo be considered a responsive and potential source, interested parties shall provide a capabilities statement containing the following information:\nBusiness name, address, point of contact, phone number and email address.\nBusiness size, type, and SAM Unique Identifier Number\nAffirmation that the vendor can provide the supplies in accordance with the attached Salient Characteristics.\n\nAdditionally, contractors can provide feedback on the attached Requirements Description, which may be considered if a solicitation is posted.\nProvide the requested information to Hector Gonzalez at hector.gonzalez1@va.gov before 10:00 AM PST on July 21st, 2026. All questions must be submitted in writing, no telephonic inquiries will be accepted.\n\nThis is a sources-sought notice only. The purpose of this notice is to obtain information regarding the availability and capability of verified sources to include qualified SDVOSB/VOSB to perform this potential requirement. Responses received will assist the Government in determining the appropriate acquisition strategy. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time, and this is not a request for quotes.\n\nSalient Characteristics\nMolecular PCR Analyzer for Detection of Pathogen s related to\nWomen s Health and Sexual Health\n\nOverview:\n\nThe Women s Health Innovation and Staffing Enhancements (WHISE) initiative awarded funding to the Jonathan M. Wainwright Memorial VA Medical Center (VAWW) Laboratory to support implementation of in-house molecular testing capability during Fiscal Year 2026 for prompt detection and reporting of pathogens related to veteran women s health and sexual health.\n\nScope Required for Women s Health and Sexual Health Testing:\n\nThe analyzer must allow for rapid in-house molecular testing with significantly improved turnaround times of 1.0 -1.5 hours (or less) for women s health and sexual health to support same-day diagnosis and treatment workflows when clinically appropriate. Must have the ability to perform Multiplex Vaginal Panel and Chlamydia trachomatis/Neisseria gonorrhoeae on a single platform (instrument) simultaneously. These two panels include:\nMultiplex Vaginal Panel (results in 60 minutes or less)\nBacterial vaginosis\nAtopobium spp.\nBacterial Vaginosis-Associated Bacterium (BVAB2)\nMegasphaera-1\nCandida spp. (C. albicans, C. tropicalis, C. parapsilosis, C. dubliniensis\nCandida glabrata/Candida krusei\nTrichomonas vaginalis\nCT/NG Panel (results in 90 minutes or less) for both males and females. Cartridge must also include sample adequacy controls to confirm the presence of human DNA.\nChlamydia trachomatis (CT) - both males and females\nNeisseria gonorrhoeae (NG) two independent targets required for accuracy\n\nTest Collection Requirements:\n\nSpecimen collection kits must be available for the following samples and FDA approved for patient self-collection in a clinical setting:\nEndocervical\nVaginal\nPharyngeal\nRectal\nUrine\nAnalyzer must be capable of performing qualitative PCR tests on self-collected samples for detection and differentiation of these DNA targets with testing multiplexed efficiently to include all analytes in the least amount of test panels.\n\nScope Required for Additional Testing:\n\nCompatibility with future decentralized and waived molecular testing workflows within the same manufacturer ecosystem represents a significant operational advantage for future outpatient and CBOC expansion strategies. Ability to consolidate all the laboratory molecular testing workflows onto one integrated platform will improve, turnaround times, operational standardization, continuity of operations, staffing efficiency, and future scalability.\n\nTherefore, the requested platform must support broader rapid molecular diagnostic testing needs including:\nCOVID-19;\ncombined COVID-19/Influenza A/B/RSV testing;\nFDA-cleared asymptomatic COVID-19 testing;\nMRSA;\nGroup A Streptococcus (Strep A);\nInfluenza A/B;\nRSV;\nand additional molecular diagnostic assays.\n\nFast Turn Around Times (TAT) vs. High Throughput:\n\nAs an ambulatory care facility, the emphasis is on quick result turnaround times and not high throughput. This instrumentation must provide prompt results (within 1.5 hours) for same day diagnosis and treatment. Analyzers designed for high throughput such as those used in reference laboratories do not meet the turnaround time requirements as they process large amounts of specimens at once but take longer overall to produce test results (3 to 4 hours).\n\nSpecifications:\n\nOptimized workflow with multi-test capacity.\nMust have the ability to run a minimum of 16 test modules simultaneously.\nMust be able to run multiple assay types and test for multiple diseases at the same time using individual cartridges.\nWorkflow simplicity and minimal hands-on time that utilize efficient user guided software with touchscreen and barcode reader.\nPre analytical workflows suited for CBOC and outpatient transport demands.\nFast throughput with test results within 1 1.5 hours.\nRequires on demand random access to allow real time testing (not batches).\nTest cartridges:\nMust be closed configuration to reduce the risk of contamination with all steps of PCR testing occurring within the cartridge (extraction, amplification and detection.\nMust include internal controls to monitor/confirm PCR reaction and verify reagent integrity.\nCT/NG Panel cartridge must also include:\nSample Adequacy Control to confirm the presence of human DNA.\nTwo independent targets required for accuracy\nFDA approved and validated for self-collected samples.\nOn board quality controls to determine run accuracy, probe function and sample adequacy.\nStability at room temperature for reagents that require significant space.\nInstrument must be able to bidirectionally interface with an LIS.\nUPS backup storage.\nPrinter\nInstrument must be benchtop with compact design with dimensions adequate for countertop space and weight limitations:\n21 width x 26 height x 14 depth\nLess than 175 lbs.\nInstallation included in quote.\nOne year service agreement included in quote and 24/7 technical support","html":"The Department of Veterans Affairs (VA), Network Contracting Office 20 (NCO 20), is conducting market research on behalf of the Jonathan M. Wainwright Memorial VA Medical Center to identify potential contractors capable of providing reagents and consumables for laboratory tests for the VA medical facilities and clinics.    \nThe Jonathan M. Wainwright Memorial VA Medical Center is comprised of: \n\nJonathan M. Wainwright Memorial VA Medical Center.\nLa Grande VA Clinic.\nLewiston VA Clinic.\nMorrow County VA Clinic.\nRichland VA Clinic\nYakima Valley VA Clinic\n\nTo be considered a responsive and potential source, interested parties shall provide a capabilities statement containing the following information:\nBusiness name, address, point of contact, phone number and email address.\nBusiness size, type, and SAM Unique Identifier Number\nAffirmation that the vendor can provide the supplies in accordance with the attached Salient Characteristics.\n\nAdditionally, contractors can provide feedback on the attached Requirements Description, which may be considered if a solicitation is posted.  \nProvide the requested information to Hector Gonzalez at hector.gonzalez1@va.gov before 10:00 AM PST on July 21st, 2026.  All questions must be submitted in writing, no telephonic inquiries will be accepted.  \n\nThis is a sources-sought notice only. The purpose of this notice is to obtain information regarding the availability and capability of verified sources to include qualified SDVOSB/VOSB to perform this potential requirement. Responses received will assist the Government in determining the appropriate acquisition strategy. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time, and this is not a request for quotes.\n\n\n\n\n\n\nSalient Characteristics\nMolecular PCR Analyzer for Detection of Pathogen s related to\nWomen s Health and Sexual Health\n\nOverview:\n\nThe Women s Health Innovation and Staffing Enhancements (WHISE) initiative awarded funding to the Jonathan M. Wainwright Memorial VA Medical Center (VAWW) Laboratory to support implementation of in-house molecular testing capability during Fiscal Year 2026 for prompt detection and reporting of pathogens related to veteran women s health and sexual health.  \n\nScope Required for Women s Health and Sexual Health Testing:\n\nThe analyzer must allow for rapid in-house molecular testing with significantly improved turnaround times of 1.0 -1.5 hours (or less) for women s health and sexual health to support same-day diagnosis and treatment workflows when clinically appropriate. Must have the ability to perform Multiplex Vaginal Panel and Chlamydia trachomatis/Neisseria gonorrhoeae on a single platform (instrument) simultaneously.  These two panels include:\nMultiplex Vaginal Panel (results in 60 minutes or less)\nBacterial vaginosis\nAtopobium spp.\nBacterial Vaginosis-Associated Bacterium (BVAB2)\nMegasphaera-1\nCandida spp. (C. albicans, C. tropicalis, C. parapsilosis, C. dubliniensis\nCandida glabrata/Candida krusei\nTrichomonas vaginalis\nCT/NG Panel (results in 90 minutes or less) for both males and females.  Cartridge must also include sample adequacy controls to confirm the presence of human DNA.\nChlamydia trachomatis (CT) - both males and females\nNeisseria gonorrhoeae (NG)   two independent targets required for accuracy\n\nTest Collection Requirements:\n\nSpecimen collection kits must be available for the following samples and FDA approved for patient self-collection in a clinical setting:\nEndocervical\nVaginal\nPharyngeal\nRectal\nUrine\nAnalyzer must be capable of performing qualitative PCR tests on self-collected samples for detection and differentiation of these DNA targets with testing multiplexed efficiently to include all analytes in the least amount of test panels.  \n\nScope Required for Additional Testing:\n\nCompatibility with future decentralized and waived molecular testing workflows within the same manufacturer ecosystem represents a significant operational advantage for future outpatient and CBOC expansion strategies. Ability to consolidate all the laboratory molecular testing workflows onto one integrated platform will improve, turnaround times, operational standardization, continuity of operations, staffing efficiency, and future scalability.\n\nTherefore, the requested platform must support broader rapid molecular diagnostic testing needs including:\nCOVID-19;\ncombined COVID-19/Influenza A/B/RSV testing;\nFDA-cleared asymptomatic COVID-19 testing;\nMRSA;\nGroup A Streptococcus (Strep A);\nInfluenza A/B;\nRSV;\nand additional molecular diagnostic assays.\n\nFast Turn Around Times (TAT) vs. High Throughput:\n\nAs an ambulatory care facility, the emphasis is on quick result turnaround times and not high throughput.  This instrumentation must provide prompt results (within 1.5 hours) for same day diagnosis and treatment.  Analyzers designed for high throughput such as those used in reference laboratories do not meet the turnaround time requirements as they process large amounts of specimens at once but take longer overall to produce test results (3 to 4 hours). \n\nSpecifications:\n\nOptimized workflow with multi-test capacity.\nMust have the ability to run a minimum of 16 test modules simultaneously.\nMust be able to run multiple assay types and test for multiple diseases at the same time using individual cartridges.\nWorkflow simplicity and minimal hands-on time that utilize efficient user guided software with touchscreen and barcode reader.   \nPre analytical workflows suited for CBOC and outpatient transport demands.\nFast throughput with test results within 1   1.5 hours.\nRequires on demand random access to allow real time testing (not batches).\nTest cartridges:\nMust be closed configuration to reduce the risk of contamination with all steps of PCR testing occurring within the cartridge (extraction, amplification and detection.\nMust include internal controls to monitor/confirm PCR reaction and verify reagent integrity.\nCT/NG Panel cartridge must also include:\n Sample Adequacy Control to confirm the presence of human DNA.\nTwo independent targets required for accuracy\nFDA approved and validated for self-collected samples.\nOn board quality controls to determine run accuracy, probe function and sample adequacy.   \nStability at room temperature for reagents that require significant space.\nInstrument must be able to bidirectionally interface with an LIS.\nUPS backup storage.\nPrinter\nInstrument must be benchtop with compact design with dimensions adequate for countertop space and weight limitations:\n21  width x 26  height x 14  depth\nLess than 175 lbs.\nInstallation included in quote.\nOne year service agreement included in quote and 24/7 technical support","origin":"detail"},"contacts":[{"name":"Hector D Gonzalez","role":"primary","email":"hector.gonzalez1@va.gov","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"naics_codes":["334516"],"award":{"awardee":{}},"attachments":[{"resource_id":"dbd3c3c03967461ea07248f1568c600e","name":"36C26026Q0844.docx","kind":"file","mime_type":".docx","size_bytes":15749,"posted_at":"2026-07-14T23:19:38.109Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dbd3c3c03967461ea07248f1568c600e/download","mirrored":false},{"resource_id":"30cd0fad0f9a43a4aa6788a74c732717","name":"36C26026Q0844_1.docx","kind":"file","mime_type":".docx","size_bytes":15597,"posted_at":"2026-07-14T23:25:32.067Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/30cd0fad0f9a43a4aa6788a74c732717/download","mirrored":false}],"awards":[],"related":[{"key":"36C26027R00020006","latest_notice_id":"299fab9bad854b0786fcc742e3f934d5","title":"Amendment 0006 to Provide Official RFI Responses, Update Solicitation Documents, Extend Proposal Due Date, & other Official Information","solicitation_number":"36C26027R0002-0006","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26027Q0117","latest_notice_id":"b6d17aea5ceb4b8d988004142043a40b","title":"6550 Reagents Consumables Microbiology Testing Boise VAMC","solicitation_number":"36C26027Q0117","notice_type":"r","first_type":"r","first_posted":"2026-11-09","last_posted":"2026-11-09","notices":1,"due_at":"2026-11-28T01:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"325413","psc":"6550","set_aside":null,"state":"ID","county":"16001","county_name":"Ada County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Boise VA Medical Center","site_key":"boise-va-medical-center-id","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"36C26026Q0981","latest_notice_id":"f9240f8b1e9a4da7aa654200bac827aa","title":"WSNC Medical Coding Books","solicitation_number":"36C26026Q0981","notice_type":"o","first_type":"o","first_posted":"2026-10-08","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-01T18:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"513130","psc":"7610","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26027R00020007","latest_notice_id":"9c90cd15f29d407c9ea106c281373e63","title":"Y1DA--CON NRM 531-25-102 | Expand Emergency Room","solicitation_number":"36C26027R0002-0007","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"68HERL27Q0018","latest_notice_id":"95332551fa5b4851bc7f5a28a560675c","title":"66--RFI & Sources Sought for GC/Q-TOF MS Lab Equipment","solicitation_number":"68HERL27Q0018","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-068","dept_name":"ENVIRONMENTAL PROTECTION AGENCY","sub_key":"s-6800","sub_name":"ENVIRONMENTAL PROTECTION AGENCY","office_key":"o-68HE0M","office_name":"LAB - ANN ARBOR, MI - CO OFFICE","naics":"334516","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"89243327QEX000002","latest_notice_id":"2507c3f1a48c4f2bad80f7ae604ba05a","title":"66--Brand Name or Equal Teledyne Instruments Liquid Sy","solicitation_number":"89243327QEX000002","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-19","notices":3,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-892433","office_name":"NATIONAL ENERGY TECHNOLOGY LABORATORY","naics":"334516","psc":"6640","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"89243327QEX000003","latest_notice_id":"1dee4e8cc79a4245a52ca82c963125bd","title":"Brand Name or Equal Across International 2R50f.110","solicitation_number":"89243327QEX000003","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-892433","office_name":"NATIONAL ENERGY TECHNOLOGY LABORATORY","naics":"334516","psc":"6640","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"}],"similar_open_total":61,"indexable":false}