{"canonical":"https://sealedbidder.com/opportunities/36c26026q0729","key":"36C26026Q0729","url":"https://sealedbidder.com/opportunities/36c26026q0729","title":"J066--Sources Sought 10X Genomics Chromium X Maintenance Service 1 Year","solicitation_number":"36C26026Q0729","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-10T22:00:00Z","first_posted":"2026-06-04","last_posted":"2026-06-04","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"811210","psc":"J066","set_aside":null,"place_state":"ID","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"16001","place_county_name":"Ada County","place_city":"1608830","place_city_name":"Boise City","winner":null,"award_amount":null,"publications":[{"notice_id":"ab671d0d744b4c98bac1b50ebcf1c020","title":"J066--Sources Sought 10X Genomics Chromium X Maintenance Service 1 Year","solicitation_number":"36C26026Q0729","notice_type":"r","base_type":"r","posted":"2026-06-04","posted_at":"2026-06-04T18:12:43.622Z","due_at":"2026-06-10T22:00:00Z","due_date":"2026-06-10","cancelled":false,"archived":true,"archive_date":"2026-06-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ab671d0d744b4c98bac1b50ebcf1c020/view","enriched":true,"history":[{"index":3,"title":"J066--Sources Sought 10X Genomics Chromium X Maintenance Service 1 Year","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-04T18:12:43.622Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ab671d0d744b4c98bac1b50ebcf1c020","solicitation_number":"36C26026Q0729"}]}],"latest_notice_id":"ab671d0d744b4c98bac1b50ebcf1c020","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-06-04","posted_at":"2026-06-04T18:12:43.622Z","created_at":"2026-06-04T18:12:41.408Z","modified_at":"2026-06-26T03:55:45.449Z","response_deadline":{"raw":"2026-06-10T15:00:00-07:00","utc":"2026-06-10T22:00:00Z","date":"2026-06-10","time":"15:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ab671d0d744b4c98bac1b50ebcf1c020/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J066--Sources Sought 10X Genomics Chromium X Maintenance Service 1 Year","agency":{"office":{"code":"36C260","name":"260-NETWORK CONTRACT OFFICE 20 (36C260)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"organization_id":"100186526","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-25","archive_type":"auto_custom"},"history":[{"index":3,"title":"J066--Sources Sought 10X Genomics Chromium X Maintenance Service 1 Year","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-04T18:12:43.622Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"ab671d0d744b4c98bac1b50ebcf1c020","solicitation_number":"36C26026Q0729"}],"contacts":[{"name":"Peter Park","role":"primary","email":"peter.park2@va.gov","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"ab671d0d744b4c98bac1b50ebcf1c020","lineage_id":"ab671d0d744b4c98bac1b50ebcf1c020","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T19:12:12.496326649Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"0127278f61550ee989e7722ac7086d10fa3134977f74454908d1c4712740f346","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-02T19:12:12.496326649Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Notice of Sources Sought\n\nThe purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Women Owned Small Businesses (WOSB) and Small Businesses interested and capable of providing the services requested, as well as any large businesses.  The results from this source sought notice will be used to determine the appropriate set-aside.\n\nThe intended contract is a firm-fixed price service contract.\n\nThe SBA Non-Manufacturer Rule is not applicable as the intended contract is for services. \n\nThe Department of Veterans Affairs, NCO20 is looking for manufacturer authorized service providers with access to OEM parts of the following requirement:\n\n12 month preventative maintenance services for existing Chromium X equipment at Boise VAMC in accordance with Statement of Work below. \nEquipment to be serviced: Chromium X - 12 month Assurance Plan \nSerial no: CXVG12468\nManufacturer: 10X Genomics\n\nStatement of Work:\n1.  Contract Title\nChromium iX - 12 month Assurance Plan - SN# CXVG12468\n2.  Background  \nBVAMC Research Service is planning to purchase a Chromium iX - 12 month Assurance Plan - SN# CXVG12468 to ensure proper maintenance of the necessary lab equipment\n3.  Scope\nThe site of the equipment will be in Research Services, building #117, 125.  The contractor provide the service contract for the already installed machine  Chromium iX \n4.  Specific Tasks\n4.1.  The contractor will extend the 12-month warranty for the system.\n5.  Performance Monitoring (if applicable)\nThe point of contact (POC) will be a Research staff member who will be an end-user of the system. The POC will coordinate all warranty concerns related to the new system.  Jay Radke will serve as the POC.\n6.  Security Requirements\nThe system will not have the need access to a VA system or VA sensitive information.  The Chromium iX & Accessory Kits is a stand-alone instrument requiring no VA Network access.  The C&A requirements do not apply, and a Security Accreditation Package is not required.\n7.  Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\nNo GFE or GFI will be needed or provided, and the contractor does not require access to any additional equipment or materials.  \n8.  Other Pertinent Information or Special Considerations\nThe contractor possesses the specific expertise required install and perform warranty work on the controller.\na.  Identification of Possible Follow-up Work.  \nIf any unforeseen issue(s) arise during the one-year warranty period.\nb.  Identification of Potential Conflicts of Interest (COI). \nIt has been determined by the COR that no conflict of interest exists with the purchase contract.\nc.  Inspection and Acceptance Criteria.  \nNo contractor will be on site. \n9.  Risk Control\nThe Research building 117 is designated as a BSL-2 facility.  The rooms are marked to denote specific hazards that are currently in use.  In the rooms where the work will be performed, the PPE requirements will be noted, as per policy.  PPE is available.  Additionally, there are no patients, nor patient care in the research buildings. \n10.  Place of Performance\nBoise VAMC\nResearch Building #117, 125\n500 W. Fort Street\nBoise, ID  83702\n11.  Period of Performance\nThe warranty period will be for 1 year starting from the day of the completion of the installation of the system.\n12.  Delivery Schedule\nPOW Task#\nDeliverable Title\nFormat\nNumber\nCalendar Days After Delivery & Installation\n1.1\n\n\n\n\n1.2\nWarranty work performed, if necessary\nContractor-determined \nformat indicating receipt of warranty services signed by POC\n1 copy to COR\nWithin warranty period of 365 days (1 yr) after installation\n\n\nRequired Information in Your Response to Sources Sought:\nIn order to be considered a valid source that can impact the set-aside determination of a possible future solicitation, potential contractors shall provide, at a minimum, the following information to peter.park2@va.gov by below response deadline:\n\n1) Company name, address, and point of contact, phone number, e-mail address, and UEI.\n\n2) Please identify your company s size in comparison to the anticipated North American Industry Classification System (NAICS) code 811210   Laboratory Instrument Repair and Maintenance Services. To be considered a small business your company must have less than 34 million dollars in average annual receipts. This notice is to determine the marketplace for this specific requirement.  Please check one of the following:\n\n[  ] yes   [  ] no     Service Disabled Veteran Owned Small Business (SDVOSB)\n[  ] yes   [  ] no     Veteran Owned Small Business (VOSB)\n[  ] yes   [  ] no     Women Owned Small Business (WOSB)\n[  ] yes   [  ] no     HUBZone\n[  ] yes   [  ] no     Small Business Manufacturers\n[  ] yes   [  ] no     All other Small Business (SB) \n[  ] yes   [  ] no     Other than Small Business\n\n3) Any socioeconomic business must have a SBA certification at https://search.certifications.sba.gov/.\n\n4) Only authorized service representatives/providers of the manufacturer with access to OEM parts will be considered.  No used, refurbished, remanufactured, or counterfeit parts will be allowed. Please provide a proof of authorized service provider letter from manufacturer stating you have access to OEM parts for repairs.\n\n5) Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination.  \n\n6) Capabilities Statement addressing the requirements in the Statement of Work to include:\nReferences for similar services currently being provided or previously provided at the required service levels as outlined in the Statement of Work.\n\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought notice.  This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.  \n\nNotice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System Award Management (SAM located on the web at www.sam.gov).  It is desirable that any Offeror to have completed their business Online Representations and Certifications Application in the System for Award Management (SAM).  \n\n\nService Address:    \nBoise VA Medical Center\n500 W Fort St\nBoise, ID 83702\n\nPoint of Contact:\nPeter Park\nContracting Officer\npeter.park2@va.gov\n\nResponse Deadline: \n06/10/2026 by 3:00pm Pacific Time","text":"Notice of Sources Sought\n\nThe purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Women Owned Small Businesses (WOSB) and Small Businesses interested and capable of providing the services requested, as well as any large businesses. The results from this source sought notice will be used to determine the appropriate set-aside.\n\nThe intended contract is a firm-fixed price service contract.\n\nThe SBA Non-Manufacturer Rule is not applicable as the intended contract is for services.\n\nThe Department of Veterans Affairs, NCO20 is looking for manufacturer authorized service providers with access to OEM parts of the following requirement:\n\n12 month preventative maintenance services for existing Chromium X equipment at Boise VAMC in accordance with Statement of Work below.\nEquipment to be serviced: Chromium X - 12 month Assurance Plan\nSerial no: CXVG12468\nManufacturer: 10X Genomics\n\nStatement of Work:\n1. Contract Title\nChromium iX - 12 month Assurance Plan - SN# CXVG12468\n2. Background\nBVAMC Research Service is planning to purchase a Chromium iX - 12 month Assurance Plan - SN# CXVG12468 to ensure proper maintenance of the necessary lab equipment\n3. Scope\nThe site of the equipment will be in Research Services, building #117, 125. The contractor provide the service contract for the already installed machine Chromium iX\n4. Specific Tasks\n4.1. The contractor will extend the 12-month warranty for the system.\n5. Performance Monitoring (if applicable)\nThe point of contact (POC) will be a Research staff member who will be an end-user of the system. The POC will coordinate all warranty concerns related to the new system. Jay Radke will serve as the POC.\n6. Security Requirements\nThe system will not have the need access to a VA system or VA sensitive information. The Chromium iX & Accessory Kits is a stand-alone instrument requiring no VA Network access. The C&A requirements do not apply, and a Security Accreditation Package is not required.\n7. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\nNo GFE or GFI will be needed or provided, and the contractor does not require access to any additional equipment or materials.\n8. Other Pertinent Information or Special Considerations\nThe contractor possesses the specific expertise required install and perform warranty work on the controller.\na. Identification of Possible Follow-up Work.\nIf any unforeseen issue(s) arise during the one-year warranty period.\nb. Identification of Potential Conflicts of Interest (COI).\nIt has been determined by the COR that no conflict of interest exists with the purchase contract.\nc. Inspection and Acceptance Criteria.\nNo contractor will be on site.\n9. Risk Control\nThe Research building 117 is designated as a BSL-2 facility. The rooms are marked to denote specific hazards that are currently in use. In the rooms where the work will be performed, the PPE requirements will be noted, as per policy. PPE is available. Additionally, there are no patients, nor patient care in the research buildings.\n10. Place of Performance\nBoise VAMC\nResearch Building #117, 125\n500 W. Fort Street\nBoise, ID 83702\n11. Period of Performance\nThe warranty period will be for 1 year starting from the day of the completion of the installation of the system.\n12. Delivery Schedule\nPOW Task#\nDeliverable Title\nFormat\nNumber\nCalendar Days After Delivery & Installation\n1.1\n\n1.2\nWarranty work performed, if necessary\nContractor-determined\nformat indicating receipt of warranty services signed by POC\n1 copy to COR\nWithin warranty period of 365 days (1 yr) after installation\n\nRequired Information in Your Response to Sources Sought:\nIn order to be considered a valid source that can impact the set-aside determination of a possible future solicitation, potential contractors shall provide, at a minimum, the following information to peter.park2@va.gov by below response deadline:\n\n1) Company name, address, and point of contact, phone number, e-mail address, and UEI.\n\n2) Please identify your company s size in comparison to the anticipated North American Industry Classification System (NAICS) code 811210 Laboratory Instrument Repair and Maintenance Services. To be considered a small business your company must have less than 34 million dollars in average annual receipts. This notice is to determine the marketplace for this specific requirement. Please check one of the following:\n\n[ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB)\n[ ] yes [ ] no Veteran Owned Small Business (VOSB)\n[ ] yes [ ] no Women Owned Small Business (WOSB)\n[ ] yes [ ] no HUBZone\n[ ] yes [ ] no Small Business Manufacturers\n[ ] yes [ ] no All other Small Business (SB)\n[ ] yes [ ] no Other than Small Business\n\n3) Any socioeconomic business must have a SBA certification at https://search.certifications.sba.gov/.\n\n4) Only authorized service representatives/providers of the manufacturer with access to OEM parts will be considered. No used, refurbished, remanufactured, or counterfeit parts will be allowed. Please provide a proof of authorized service provider letter from manufacturer stating you have access to OEM parts for repairs.\n\n5) Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination.\n\n6) Capabilities Statement addressing the requirements in the Statement of Work to include:\nReferences for similar services currently being provided or previously provided at the required service levels as outlined in the Statement of Work.\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.\n\nNotice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application in the System for Award Management (SAM).\n\nService Address:\nBoise VA Medical Center\n500 W Fort St\nBoise, ID 83702\n\nPoint of Contact:\nPeter Park\nContracting Officer\npeter.park2@va.gov\n\nResponse Deadline:\n06/10/2026 by 3:00pm Pacific Time","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26026Q0729","place_of_performance":{"zip":"83702","city":{"name":"Boise"},"state":{"name":"ID"},"street":"Boise VA Medical Center 500 West Fort Street"},"product_service_code":"J066"}],"due_at":"2026-06-10T22:00:00Z","due_date":"2026-06-10","closes_at":"2026-06-10T22:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":null,"state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T19:52:37.706099Z","principal_notice_id":"ab671d0d744b4c98bac1b50ebcf1c020","description":{"text":"Notice of Sources Sought\n\nThe purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Women Owned Small Businesses (WOSB) and Small Businesses interested and capable of providing the services requested, as well as any large businesses. The results from this source sought notice will be used to determine the appropriate set-aside.\n\nThe intended contract is a firm-fixed price service contract.\n\nThe SBA Non-Manufacturer Rule is not applicable as the intended contract is for services.\n\nThe Department of Veterans Affairs, NCO20 is looking for manufacturer authorized service providers with access to OEM parts of the following requirement:\n\n12 month preventative maintenance services for existing Chromium X equipment at Boise VAMC in accordance with Statement of Work below.\nEquipment to be serviced: Chromium X - 12 month Assurance Plan\nSerial no: CXVG12468\nManufacturer: 10X Genomics\n\nStatement of Work:\n1. Contract Title\nChromium iX - 12 month Assurance Plan - SN# CXVG12468\n2. Background\nBVAMC Research Service is planning to purchase a Chromium iX - 12 month Assurance Plan - SN# CXVG12468 to ensure proper maintenance of the necessary lab equipment\n3. Scope\nThe site of the equipment will be in Research Services, building #117, 125. The contractor provide the service contract for the already installed machine Chromium iX\n4. Specific Tasks\n4.1. The contractor will extend the 12-month warranty for the system.\n5. Performance Monitoring (if applicable)\nThe point of contact (POC) will be a Research staff member who will be an end-user of the system. The POC will coordinate all warranty concerns related to the new system. Jay Radke will serve as the POC.\n6. Security Requirements\nThe system will not have the need access to a VA system or VA sensitive information. The Chromium iX & Accessory Kits is a stand-alone instrument requiring no VA Network access. The C&A requirements do not apply, and a Security Accreditation Package is not required.\n7. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\nNo GFE or GFI will be needed or provided, and the contractor does not require access to any additional equipment or materials.\n8. Other Pertinent Information or Special Considerations\nThe contractor possesses the specific expertise required install and perform warranty work on the controller.\na. Identification of Possible Follow-up Work.\nIf any unforeseen issue(s) arise during the one-year warranty period.\nb. Identification of Potential Conflicts of Interest (COI).\nIt has been determined by the COR that no conflict of interest exists with the purchase contract.\nc. Inspection and Acceptance Criteria.\nNo contractor will be on site.\n9. Risk Control\nThe Research building 117 is designated as a BSL-2 facility. The rooms are marked to denote specific hazards that are currently in use. In the rooms where the work will be performed, the PPE requirements will be noted, as per policy. PPE is available. Additionally, there are no patients, nor patient care in the research buildings.\n10. Place of Performance\nBoise VAMC\nResearch Building #117, 125\n500 W. Fort Street\nBoise, ID 83702\n11. Period of Performance\nThe warranty period will be for 1 year starting from the day of the completion of the installation of the system.\n12. Delivery Schedule\nPOW Task#\nDeliverable Title\nFormat\nNumber\nCalendar Days After Delivery & Installation\n1.1\n\n1.2\nWarranty work performed, if necessary\nContractor-determined\nformat indicating receipt of warranty services signed by POC\n1 copy to COR\nWithin warranty period of 365 days (1 yr) after installation\n\nRequired Information in Your Response to Sources Sought:\nIn order to be considered a valid source that can impact the set-aside determination of a possible future solicitation, potential contractors shall provide, at a minimum, the following information to peter.park2@va.gov by below response deadline:\n\n1) Company name, address, and point of contact, phone number, e-mail address, and UEI.\n\n2) Please identify your company s size in comparison to the anticipated North American Industry Classification System (NAICS) code 811210 Laboratory Instrument Repair and Maintenance Services. To be considered a small business your company must have less than 34 million dollars in average annual receipts. This notice is to determine the marketplace for this specific requirement. Please check one of the following:\n\n[ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB)\n[ ] yes [ ] no Veteran Owned Small Business (VOSB)\n[ ] yes [ ] no Women Owned Small Business (WOSB)\n[ ] yes [ ] no HUBZone\n[ ] yes [ ] no Small Business Manufacturers\n[ ] yes [ ] no All other Small Business (SB)\n[ ] yes [ ] no Other than Small Business\n\n3) Any socioeconomic business must have a SBA certification at https://search.certifications.sba.gov/.\n\n4) Only authorized service representatives/providers of the manufacturer with access to OEM parts will be considered. No used, refurbished, remanufactured, or counterfeit parts will be allowed. Please provide a proof of authorized service provider letter from manufacturer stating you have access to OEM parts for repairs.\n\n5) Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination.\n\n6) Capabilities Statement addressing the requirements in the Statement of Work to include:\nReferences for similar services currently being provided or previously provided at the required service levels as outlined in the Statement of Work.\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought notice. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.\n\nNotice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application in the System for Award Management (SAM).\n\nService Address:\nBoise VA Medical Center\n500 W Fort St\nBoise, ID 83702\n\nPoint of Contact:\nPeter Park\nContracting Officer\npeter.park2@va.gov\n\nResponse Deadline:\n06/10/2026 by 3:00pm Pacific Time","html":"Notice of Sources Sought\n\nThe purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB), Women Owned Small Businesses (WOSB) and Small Businesses interested and capable of providing the services requested, as well as any large businesses.  The results from this source sought notice will be used to determine the appropriate set-aside.\n\nThe intended contract is a firm-fixed price service contract.\n\nThe SBA Non-Manufacturer Rule is not applicable as the intended contract is for services. \n\nThe Department of Veterans Affairs, NCO20 is looking for manufacturer authorized service providers with access to OEM parts of the following requirement:\n\n12 month preventative maintenance services for existing Chromium X equipment at Boise VAMC in accordance with Statement of Work below. \nEquipment to be serviced: Chromium X - 12 month Assurance Plan \nSerial no: CXVG12468\nManufacturer: 10X Genomics\n\nStatement of Work:\n1.  Contract Title\nChromium iX - 12 month Assurance Plan - SN# CXVG12468\n2.  Background  \nBVAMC Research Service is planning to purchase a Chromium iX - 12 month Assurance Plan - SN# CXVG12468 to ensure proper maintenance of the necessary lab equipment\n3.  Scope\nThe site of the equipment will be in Research Services, building #117, 125.  The contractor provide the service contract for the already installed machine  Chromium iX \n4.  Specific Tasks\n4.1.  The contractor will extend the 12-month warranty for the system.\n5.  Performance Monitoring (if applicable)\nThe point of contact (POC) will be a Research staff member who will be an end-user of the system. The POC will coordinate all warranty concerns related to the new system.  Jay Radke will serve as the POC.\n6.  Security Requirements\nThe system will not have the need access to a VA system or VA sensitive information.  The Chromium iX & Accessory Kits is a stand-alone instrument requiring no VA Network access.  The C&A requirements do not apply, and a Security Accreditation Package is not required.\n7.  Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI)\nNo GFE or GFI will be needed or provided, and the contractor does not require access to any additional equipment or materials.  \n8.  Other Pertinent Information or Special Considerations\nThe contractor possesses the specific expertise required install and perform warranty work on the controller.\na.  Identification of Possible Follow-up Work.  \nIf any unforeseen issue(s) arise during the one-year warranty period.\nb.  Identification of Potential Conflicts of Interest (COI). \nIt has been determined by the COR that no conflict of interest exists with the purchase contract.\nc.  Inspection and Acceptance Criteria.  \nNo contractor will be on site. \n9.  Risk Control\nThe Research building 117 is designated as a BSL-2 facility.  The rooms are marked to denote specific hazards that are currently in use.  In the rooms where the work will be performed, the PPE requirements will be noted, as per policy.  PPE is available.  Additionally, there are no patients, nor patient care in the research buildings. \n10.  Place of Performance\nBoise VAMC\nResearch Building #117, 125\n500 W. Fort Street\nBoise, ID  83702\n11.  Period of Performance\nThe warranty period will be for 1 year starting from the day of the completion of the installation of the system.\n12.  Delivery Schedule\nPOW Task#\nDeliverable Title\nFormat\nNumber\nCalendar Days After Delivery & Installation\n1.1\n\n\n\n\n1.2\nWarranty work performed, if necessary\nContractor-determined \nformat indicating receipt of warranty services signed by POC\n1 copy to COR\nWithin warranty period of 365 days (1 yr) after installation\n\n\nRequired Information in Your Response to Sources Sought:\nIn order to be considered a valid source that can impact the set-aside determination of a possible future solicitation, potential contractors shall provide, at a minimum, the following information to peter.park2@va.gov by below response deadline:\n\n1) Company name, address, and point of contact, phone number, e-mail address, and UEI.\n\n2) Please identify your company s size in comparison to the anticipated North American Industry Classification System (NAICS) code 811210   Laboratory Instrument Repair and Maintenance Services. To be considered a small business your company must have less than 34 million dollars in average annual receipts. This notice is to determine the marketplace for this specific requirement.  Please check one of the following:\n\n[  ] yes   [  ] no     Service Disabled Veteran Owned Small Business (SDVOSB)\n[  ] yes   [  ] no     Veteran Owned Small Business (VOSB)\n[  ] yes   [  ] no     Women Owned Small Business (WOSB)\n[  ] yes   [  ] no     HUBZone\n[  ] yes   [  ] no     Small Business Manufacturers\n[  ] yes   [  ] no     All other Small Business (SB) \n[  ] yes   [  ] no     Other than Small Business\n\n3) Any socioeconomic business must have a SBA certification at https://search.certifications.sba.gov/.\n\n4) Only authorized service representatives/providers of the manufacturer with access to OEM parts will be considered.  No used, refurbished, remanufactured, or counterfeit parts will be allowed. Please provide a proof of authorized service provider letter from manufacturer stating you have access to OEM parts for repairs.\n\n5) Please provide a courtesy quote in response to this request to evaluate price reasonableness for any set-aside determination.  \n\n6) Capabilities Statement addressing the requirements in the Statement of Work to include:\nReferences for similar services currently being provided or previously provided at the required service levels as outlined in the Statement of Work.\n\n\nThe Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought notice.  This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.  \n\nNotice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System Award Management (SAM located on the web at www.sam.gov).  It is desirable that any Offeror to have completed their business Online Representations and Certifications Application in the System for Award Management (SAM).  \n\n\nService Address:    \nBoise VA Medical Center\n500 W Fort St\nBoise, ID 83702\n\nPoint of Contact:\nPeter Park\nContracting Officer\npeter.park2@va.gov\n\nResponse Deadline: \n06/10/2026 by 3:00pm Pacific Time","origin":"detail"},"contacts":[{"name":"Peter Park","role":"primary","email":"peter.park2@va.gov","title":"Contracting Officer"}],"place_of_performance":{"zip":"83702","city":{"name":"Boise"},"state":{"name":"ID"},"street":"Boise VA Medical Center 500 West Fort Street"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"1d3d440b9ee348f38c32913620417bc5","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2026-06-04T18:12:43.622Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/boise-health-care/","mirrored":false}],"awards":[],"related":[{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26027Q0117","latest_notice_id":"b6d17aea5ceb4b8d988004142043a40b","title":"6550 Reagents Consumables Microbiology Testing Boise VAMC","solicitation_number":"36C26027Q0117","notice_type":"r","first_type":"r","first_posted":"2026-11-09","last_posted":"2026-11-09","notices":1,"due_at":"2026-11-28T01:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"325413","psc":"6550","set_aside":null,"state":"ID","county":"16001","county_name":"Ada County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Boise VA Medical Center","site_key":"boise-va-medical-center-id","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"36C26026Q0981","latest_notice_id":"f9240f8b1e9a4da7aa654200bac827aa","title":"WSNC Medical Coding Books","solicitation_number":"36C26026Q0981","notice_type":"o","first_type":"o","first_posted":"2026-10-08","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-01T18:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"513130","psc":"7610","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26027R00020007","latest_notice_id":"9c90cd15f29d407c9ea106c281373e63","title":"Y1DA--CON NRM 531-25-102 | Expand Emergency Room","solicitation_number":"36C26027R0002-0007","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C26027R0021","latest_notice_id":"7a19b19c49c240a496641c5f39341d63","title":"Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center","solicitation_number":"36C26027R0021","notice_type":"o","first_type":"p","first_posted":"2026-10-16","last_posted":"2026-11-24","notices":5,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"238220","psc":"Z1DA","set_aside":"SDVOSBC","state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Mann-Grandstaff VA Medical Center","site_key":"mann-grandstaff-va-medical-center-wa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C26227Q0063","latest_notice_id":"57c32e663caa45e58aecf5d9fcc6fe70","title":"J065--ALCON CONSTELLATION LXT AND EMBEDDED LASERS & ALCON CENTURION VISION PHACOEMULSIFICATION PMI SVCS","solicitation_number":"36C26227Q0063","notice_type":"k","first_type":"r","first_posted":"2026-10-21","last_posted":"2026-11-20","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C262","office_name":"262-NETWORK CONTRACT OFFICE 22 (36C262)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0643000","city_name":"Long Beach","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"IHS1532582","latest_notice_id":"e43a8d0bba28406f8903b22a88a9e950","title":"Ventilator Full-Service Maintenance","solicitation_number":"IHS1532582","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H721","office_name":"LAWTON INDIAN HOSPITAL","naics":"811210","psc":"J065","set_aside":"ISBEE","state":"OK","county":"40031","county_name":"Comanche County","city":"4041850","city_name":"Lawton","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":58,"indexable":false}