{"canonical":"https://sealedbidder.com/opportunities/36c26026q0462","key":"36C26026Q0462","url":"https://sealedbidder.com/opportunities/36c26026q0462","title":"H965--Walla Walla VA Medical Center - Generator and Fuel Testing","solicitation_number":"36C26026Q0462","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-23T19:00:00Z","first_posted":"2026-03-16","last_posted":"2026-03-16","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"811310","psc":"H965","set_aside":null,"place_state":"WA","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"53071","place_county_name":"Walla Walla County","place_city":"5375775","place_city_name":"Walla Walla","winner":null,"award_amount":null,"publications":[{"notice_id":"298ee6639d364f93bddb68faa1ed2871","title":"H965--Walla Walla VA Medical Center - Generator and Fuel Testing","solicitation_number":"36C26026Q0462","notice_type":"r","base_type":"r","posted":"2026-03-16","posted_at":"2026-03-16T21:50:30.649Z","due_at":"2026-03-23T19:00:00Z","due_date":"2026-03-23","cancelled":false,"archived":true,"archive_date":"2026-04-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/298ee6639d364f93bddb68faa1ed2871/view","enriched":true,"history":[{"index":3,"title":"H965--Walla Walla VA Medical Center - Generator and Fuel Testing","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T21:50:30.649Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"298ee6639d364f93bddb68faa1ed2871","solicitation_number":"36C26026Q0462"}]}],"latest_notice_id":"298ee6639d364f93bddb68faa1ed2871","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-03-16","posted_at":"2026-03-16T21:50:30.649Z","created_at":"2026-03-16T21:50:28.446Z","modified_at":"2026-04-07T03:55:45.217Z","response_deadline":{"raw":"2026-03-23T12:00:00-07:00","utc":"2026-03-23T19:00:00Z","date":"2026-03-23","time":"12:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/298ee6639d364f93bddb68faa1ed2871/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"H965--Walla Walla VA Medical Center - Generator and Fuel Testing","agency":{"office":{"code":"36C260","name":"260-NETWORK CONTRACT OFFICE 20 (36C260)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"organization_id":"100186526","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-04-06","archive_type":"auto_custom"},"history":[{"index":3,"title":"H965--Walla Walla VA Medical Center - Generator and Fuel Testing","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-16T21:50:30.649Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"298ee6639d364f93bddb68faa1ed2871","solicitation_number":"36C26026Q0462"}],"contacts":[{"name":"Michael Allred","role":"primary","email":"michael.allred1@va.gov","phone":"5093211906","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"298ee6639d364f93bddb68faa1ed2871","lineage_id":"298ee6639d364f93bddb68faa1ed2871","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-11T02:55:02.691234832Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"b760a0695957fb453939e37f6fbbc8b3eb583a78236dba776c8371e6be543e89","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-11T02:55:02.691234832Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"The Department of Veterans Affairs (VA), Network Contracting Office 20 (NCO 20), is conducting market research on behalf of the Walla Walla VAMC to identify potential contractors capable of providing generator and fuel testing services. \nTo be considered a responsive and potential source, interested parties shall provide a capabilities statement containing the following information: \nBusiness name, address, point of contact, phone number and email address. \nBusiness size designation (under NAICS 811310 sized standard $12.5M), type (SDVOSB, VOSB, WOSB or other), and SAM Unique Identifier Number \nAffirmation that the vendor is capable of performing in accordance with the attached Draft Performance Work Statement. \nAlso, vendors shall include at least one example of relevant past performance wherein it is shown the quoter has performed similar work meeting similar performance standards in the past. \nAffirmation that the vendor is capable of performing in compliance with the Limitations on Subcontracting, in accordance with VAAR 852.219-75,  if this were to be set-aside for SD/VOSBs or other Small Businesses.\nAdditionally, contractors can provide feedback on the attached Draft Performance Work Statement, which may be considered if a solicitation is posted. \nProvide the requested information to Michael Allred at michael.allred1@va.gov before 12:00 PM PST on March 23rd, 2026. All questions must be submitted via email, no telephonic inquiries will be accepted.\nThis is a sources-sought notice only. The purpose of this notice is to obtain information regarding the availability and capability of ALL verified sources to include qualified SDVOSB/VOSB to perform this potential requirement. Responses received will assist the Government in determining the appropriate acquisition strategy. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time, and this is not a request for quotes.\nSee attached document: Draft Statement of Work.\n \nEB.3 STATEMENT OF WORK (SOW)\n\nTitle: Emergency Generator Load and Fuel Testing\n\nBackground\n\nThe Jonathan M Wainwright Memorial VA Medical Center (VAWW), located at 77 Wainwright Drive, Walla Walla, WA, requires annual and triennial testing of emergency generators as required by NFPA 110 and fuel testing per NFPA 110 Part 8.3.7. There are currently eight diesel electric generators on the VAWW campus which have insufficient connected load and require annual testing with a supplemental load bank. There are 9 fuel storage containers that need to be tested as well.  \n\nPlace of Performance\n\nAll work under this contract is to be performed at the following locations: \n\nWalla Walla VA Medical Center, 77 Wainwright Dr, Walla Walla, WA 99362\n\nScope \n\nContractor shall furnish all labor, travel, equipment, supplies, and materials required to perform a complete inspection, testing, maintenance and repair service of the systems in accordance with the frequency and procedures outlined in the most current edition of the Applicable publications mentioned throughout all of the identified scope below.\n\nProvide annual inspections and supplemental load bank testing according to the following NFPA 110 and VA Directive 1028 language:\n\nIf the monthly EPSS tests cannot exercise the generators at 30 percent load or acceptable stack exhaust temperature, an annual test must be conducted using supplemental load banks. Such test must meet applicable requirements of NFPA 99, NFPA 110, and The Joint Commission.\n\nThe generator must be tested at 50% nameplate load for the first 30 minutes and then at 75% nameplate load for 60 minutes following the first 30 minutes. In total, the generator will be tested for 1.5 hours.\n\nProvide annual fuel testing per NFPA 110, generator manufacture s recommendations and ASTM testing standards to validate that the quality of fuel complies with manufacture s acceptable ranges for proper generator functionality.\n\nProvide triennial generator testing using supplemental load bank testing according to the following VA Directive 1028 and The Joint Commission language:\n\nThe Joint Commission requires a 4-hour generator test under load (dynamic or static) that is at least 30 percent of the nameplate rating of the generator once every 36 months. To accomplish this the VA requests that the generator is tested for 180 minutes at 30% of nameplate load and then tested for 60 minutes at 75% nameplate load.\nThe contractor will not perform annual tests during the same year that triennial tests are required. The VA has an agreement with NFPA that when triennial testing is performed to VA standards, NFPA accepts that our triennial testing as an annual test.\n\nAPPLICABLE PUBLICATIONS: The publications listed below shall be followed when engaging in any work required by this contract. There are specific references called out, but it is still expected that any requirements of these codes are followed. The most current edition of these standards shall be applicable. \n\nNational Fire Protection Association (NFPA): \nNFPA 110 Standard for Emergency and Standby Power Systems\nUnderwriters  Laboratories, Inc. (UL)\nAmerican Society for Testing and Materials (ASTM) Including but not limited to:\nASTM D975\nThe Joint Commission (TJC) Environment of Care Manual\n\nNotification/Coordination\n\nUpon award the Contracting Officer (CO) may designate a Representative (COR) to supervise the work performed for the duration of this contract. However, in no event, will any understanding, agreement, modification, change order, or other matter deviating from the terms of the contract between the contractor and any person other than the CO be effective or binding upon the Government, unless formalized by proper contractual documents executed by the CO, prior to completion of this contract. A copy of this designation shall be furnished to the Contractor.\n\nThe contractor shall perform triennial testing during the base year to set the cyclic period for this requirement. Within thirty days after contract award, for base and option years, the contractor shall provide the VA with an annual inspection and testing schedule, distinguishing between yearly and triennial events. The estimated yearly schedule is subject to COR approval. The Contractor shall provide the COR a finalized schedule for each task 30 days before the intended inspection and testing to confirm the scheduled date is still acceptable.\n\nThe Contractor and any Subcontractor shall report to the COR when arriving to perform any service under this requirement, including repairs only at the Walla Walla location. The contractor shall call the COR and coordinate with the clinic manager when arriving at the VA clinic. Check-in/out is mandatory at VA Police to obtain temporary badge.  When the service is completed, the Contractor and any Subcontractor shall check out with the COR as well.\n\nThe Contractor shall coordinate with the Subcontractor directly for any tasks associated with SOW. It is the responsibility of the Contractor to ensure Subcontractor performs all work in accordance with the SOW.\n\nDeliverables\n\nInspection/Testing Reports\n\nWhen inspections are completed at the end of each day before the field technician leaves the site, they are required to furnish a digital or electronic copy of their field testing notes to the COR. \n\nDeliver the final report to the COR no more than 30 days after completion of inspection and testing.  This will be in electronic format.\n\nIf deficiencies are discovered during inspection and testing, the final report and the field testing notes are required to have a description of the system conditions, description of corrected measures needed and any other special notes (tests conducted and maintenance work that may need to be performed). The service technician signs and submits this form to the COR.  \n\nAll services under this contract shall conform with the National Fire Protection Agency (NFPA), Occupational Safety and Health Administration (OSHA), and Original Equipment Manufacturer standards and specifications.\n\nInspection and Acceptance Criteria  \n\nThe COR is responsible for monitoring and inspecting  work performed  under this contract is in accordance with the Statement of Work. \n\nThe Contractor and COR will work together to resolve deficiencies. Work not completed or not acceptable under general industry standards cannot be certified for payment. \n\n\nStandards and Qualifications\n\nGenerator Testing and Maintenance\n\nAll Generator Technicians shall have the experience and training to perform the work and hold a current license or certification for installation of the systems involved. They must be certified by Caterpillar Inc. (CAT) through their training programs or by official documentation. \n\nNumber of Employees. The Contractor shall always have available a sufficient number of capable and qualified employees to enable the contractor to properly, adequately, and safely perform all work required under the terms of this contract.\n\nLicenses & Permits. Contractor and subcontractor personnel engaged in the activities specified by this contract shall be also required to possess certificates of training, licenses, and permits as required by the state, county, parish, city, and other local jurisdictions.\n\nDocumentation. The Contractor shall provide to the Contracting Officer Representative (COR) or Contracting Officer Designee documentation of the certificates of training, licenses, and permits for all new employees not later than seven (7) days prior to that person beginning work under the terms of this contract. licenses, permits, and bonds are current and valid.  All offers must include documentation and proof of the above certifications and qualifications for each employee.\n\nDamage to Generators:  Any damage to the generator or associated equipment (e.g. fans, pumps, electrical switchgear) caused by normal testing shall be repaired by the Contractor at no additional cost to the Government. At its discretion, the Government may have representatives present to witness any or all such tests. All costs associated with this damage shall be borne by the Contractor.\n\nWork Hours\n\nNormal Work Hours are defined as Monday through Friday from 8 a.m. to 4:30 p.m., excluding federal holidays or as otherwise arranged with the COR.  The COR will communicate with the Contractor if work, inspection, testing, repair, etc. is able to be scheduled during normal work hours. \n\nAfter Hours. The Contractor shall be required to perform some work, inspection, test, and repair outside the normal working hours of the building occupants or due to emergency conditions.  Any scheduled work that is disruptive to the tenants during annual and triennial tests (generator noise or fumes from generator) shall be performed after the building occupant's normal working hours for the following generators: B86 Caterpillar/LC5, B86 Caterpillar C18, and B143 Caterpillar/L7C.\n\nThe holidays observed by the Federal Government are New Year's Day, Martin Luther King Day, President's Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day.  Also, any other day declared by the President of the United States to be a national holiday.\n\nRisk Control\n\nThe Contractor shall comply with all applicable Federal, State, and local laws and regulations to include responsibility to conform by current Occupational, Safety, Health Administration (OSHA) & Environmental Protection Agency (EPA) regulations while working on this facility. Contractor shall comply with Walla Walla VA safety, security, and screening requirements.\n\nContractor is responsible for all reports required or requested by Federal, State and Local ordinances that pertain to any duties contained in the contract.\n\nAll Contractor employees must wear a reflective vest or suitable substitute approved by the COR. \n\nAll equipment operators shall yield to all pedestrians and traffic. All trucks that are hauling generator equipment must have proper company identification prominently displayed on them to inform facility police when they are conducting rounds.\n\nContractor shall take all precautions necessary to protect persons and property from injury or damage during the performance of this contract. Contractor shall be responsible for any injury to any Contractor s representative, or others, as well as for any damage to any personal or public property that occurs during the performance of this contract that is caused by the Contractor s fault or negligence.\n\nThe Government shall inform the Contractor of any known ACM in a generator enclosure. If the Contractor must disturb materials he suspects may contain ACM, the Contractor shall immediately report it to the Contracting Officer Representative (COR) or Contracting Officer Designee, and the Contracting Officer Representative (COR) or Contracting Officer Designee will investigate and instruct the Contractor how to avoid an airborne asbestos exposure.\n\nLead -Based Paint: The Government shall inform the Contractor of any known lead-based paint in a generator enclosure. If the Contractor must disturb materials he suspects may contain lead-based paint, the Contractor shall immediately report it to the Contracting Officer Representative (COR) or Contracting Officer Designee, and Contracting Officer Representative (COR) or Contracting Officer Designee will investigate and instruct the Contractor how to avoid lead-based paint contamination.\n\nHousekeeping. The Contractor shall leave areas where he performs work neat, clean and orderly.\n\nAll damage done by the Contractor shall become the Contractor s responsibility and expense.\n\nContractor and/or Sub-contractor shall not have any history of previous safety violations at the Walla Walla VA campus.  \n\nSecurity Requirements\n\nFollowing contract award, the Contractor is required to present a list of personnel and their qualifications, to include a contract manager that will supervise the performance of this contract to the Contracting Officer. All supervisory Contractor personnel shall be able to communicate well with the COR or designee. All Contractor employees are subject to current Medical Center Directives applicable to their conduct.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI). \n\nNot applicable\n\nContract Administrator\n\nThe Contractor shall establish processes and assign appropriate resources to effectively administer the requirement. The Contract Administrator shall respond to Government requests for contractual actions in a timely fashion and take immediate action to correct any deficiencies found. The Contractor shall have a single point of contact between the Government and Contractor personnel assigned to support the contract. An alternate point of contact may be assigned at the approval of the Contracting Officer. The Contract Administrator shall attend Quarterly Meetings as described below. \n\nContract Administrator shall in-person attend Annual Inspection and supervise any contractor or subcontractor personnel. Contract Administrator shall meet with COR while on-site to discuss any pertinent inspection information, deficiencies, and/or future coordination items. \n\nContract Administrator shall be the main POC for Repairs and Rider work unless an Alternative POC is approved by the COR. The Contract Administrator will respond promptly to CFR and emergent requests and coordinate all aspects of the work diligently with any Contractor or Subcontractor personnel while informing the COR daily of status and coordinating further approval as applicable. \n\nContract Administrator shall ensure all submitted invoices are correct and verifiable in accordance with invoices procedures outlined. \n\nThe Contract Administrator and/or assigned alternate shall be able to communicate well with the COR or designee and respond within one (1) business day to COR and/or CO inquiries.\n\nDeliverable: Contractor shall provide Contract Administrator name, email, direct phone information and resume at quote submission and three (3) business days after change of personnel to the Contracting Officer and COR. \n\n\nMiscellaneous\n\nGovernment does not pay for services not received.\n\n\nAppendix A: Generator Inventory and Fuel Tank Locations\nGenerator Inventory\nLocation   Building\nMake/Model\nVoltage\nRated KW\nLoad Testing Required\nB86\nCaterpillar/LC5\n208\n250\nYes\nB143   Outpatient Clinic\nCaterpillar/L7C\n480\n600\nYes\nB78   Theater\nJohn Deere/A75JFTL3\n208\n90\nYes\nB76   Boiler Plant\nCaterpillar/C7.1\n208\n260\nYes\nB140   RRU\nGenerac/13653720100\n480\n150\nYes\nB145   Specialty Care Clinic\nCaterpillar/LC5\n480\n175\nYes\nB74\nCummins QSB7\n480\n125\nYes\nB86\nCaterpillar/C18\n480\n600\nYes\nFuel Tank Inventory\nTank #\nBuilding\nLocation\nReason\nGallons\nQuantity\nAbove/Underground\n1\n76\nNext to Boiler Plant, behind double set of steel doors\nBoiler Contingency Fuel\n20,000\n2\nUnderground\n2\n76\nBehind 76 with set of double steel doors\nFuel for 76 Generator and 80 Generator\n6500\n1\nUnderground\n3\n78\nWest end of 78 covered by concrete pad\nFuel for 78 Generator\n1100\n1\nUnderground\n4\n86\nSouth end in walled enclosure\nFuel for Adjacent Generator\n480\n1\nAboveground\n5\n140\nWest side of building\nFuel for 140 Generator\n480\n1\nAboveground\n6\n143\nSoutheast corner of building in walled enclosure\nFuel for 143 Generator\n900\n1\nAboveground\n7\n145\nSouthwest corner of building in walled enclosure\nFuel for 145 Generator\n900\n1\nAboveground\n8\n86\nDouble walled integrated tank, south end of building\nFuel for Adjacent Generator\n380\n1\nAboveground\n9\n74\nRight next to generator in double walled tank\nFuel for Building Generator\n350\n1\nAboveground","text":"The Department of Veterans Affairs (VA), Network Contracting Office 20 (NCO 20), is conducting market research on behalf of the Walla Walla VAMC to identify potential contractors capable of providing generator and fuel testing services.\nTo be considered a responsive and potential source, interested parties shall provide a capabilities statement containing the following information:\nBusiness name, address, point of contact, phone number and email address.\nBusiness size designation (under NAICS 811310 sized standard $12.5M), type (SDVOSB, VOSB, WOSB or other), and SAM Unique Identifier Number\nAffirmation that the vendor is capable of performing in accordance with the attached Draft Performance Work Statement.\nAlso, vendors shall include at least one example of relevant past performance wherein it is shown the quoter has performed similar work meeting similar performance standards in the past.\nAffirmation that the vendor is capable of performing in compliance with the Limitations on Subcontracting, in accordance with VAAR 852.219-75, if this were to be set-aside for SD/VOSBs or other Small Businesses.\nAdditionally, contractors can provide feedback on the attached Draft Performance Work Statement, which may be considered if a solicitation is posted.\nProvide the requested information to Michael Allred at michael.allred1@va.gov before 12:00 PM PST on March 23rd, 2026. All questions must be submitted via email, no telephonic inquiries will be accepted.\nThis is a sources-sought notice only. The purpose of this notice is to obtain information regarding the availability and capability of ALL verified sources to include qualified SDVOSB/VOSB to perform this potential requirement. Responses received will assist the Government in determining the appropriate acquisition strategy. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time, and this is not a request for quotes.\nSee attached document: Draft Statement of Work.\n\nEB.3 STATEMENT OF WORK (SOW)\n\nTitle: Emergency Generator Load and Fuel Testing\n\nBackground\n\nThe Jonathan M Wainwright Memorial VA Medical Center (VAWW), located at 77 Wainwright Drive, Walla Walla, WA, requires annual and triennial testing of emergency generators as required by NFPA 110 and fuel testing per NFPA 110 Part 8.3.7. There are currently eight diesel electric generators on the VAWW campus which have insufficient connected load and require annual testing with a supplemental load bank. There are 9 fuel storage containers that need to be tested as well.\n\nPlace of Performance\n\nAll work under this contract is to be performed at the following locations:\n\nWalla Walla VA Medical Center, 77 Wainwright Dr, Walla Walla, WA 99362\n\nScope\n\nContractor shall furnish all labor, travel, equipment, supplies, and materials required to perform a complete inspection, testing, maintenance and repair service of the systems in accordance with the frequency and procedures outlined in the most current edition of the Applicable publications mentioned throughout all of the identified scope below.\n\nProvide annual inspections and supplemental load bank testing according to the following NFPA 110 and VA Directive 1028 language:\n\nIf the monthly EPSS tests cannot exercise the generators at 30 percent load or acceptable stack exhaust temperature, an annual test must be conducted using supplemental load banks. Such test must meet applicable requirements of NFPA 99, NFPA 110, and The Joint Commission.\n\nThe generator must be tested at 50% nameplate load for the first 30 minutes and then at 75% nameplate load for 60 minutes following the first 30 minutes. In total, the generator will be tested for 1.5 hours.\n\nProvide annual fuel testing per NFPA 110, generator manufacture s recommendations and ASTM testing standards to validate that the quality of fuel complies with manufacture s acceptable ranges for proper generator functionality.\n\nProvide triennial generator testing using supplemental load bank testing according to the following VA Directive 1028 and The Joint Commission language:\n\nThe Joint Commission requires a 4-hour generator test under load (dynamic or static) that is at least 30 percent of the nameplate rating of the generator once every 36 months. To accomplish this the VA requests that the generator is tested for 180 minutes at 30% of nameplate load and then tested for 60 minutes at 75% nameplate load.\nThe contractor will not perform annual tests during the same year that triennial tests are required. The VA has an agreement with NFPA that when triennial testing is performed to VA standards, NFPA accepts that our triennial testing as an annual test.\n\nAPPLICABLE PUBLICATIONS: The publications listed below shall be followed when engaging in any work required by this contract. There are specific references called out, but it is still expected that any requirements of these codes are followed. The most current edition of these standards shall be applicable.\n\nNational Fire Protection Association (NFPA):\nNFPA 110 Standard for Emergency and Standby Power Systems\nUnderwriters Laboratories, Inc. (UL)\nAmerican Society for Testing and Materials (ASTM) Including but not limited to:\nASTM D975\nThe Joint Commission (TJC) Environment of Care Manual\n\nNotification/Coordination\n\nUpon award the Contracting Officer (CO) may designate a Representative (COR) to supervise the work performed for the duration of this contract. However, in no event, will any understanding, agreement, modification, change order, or other matter deviating from the terms of the contract between the contractor and any person other than the CO be effective or binding upon the Government, unless formalized by proper contractual documents executed by the CO, prior to completion of this contract. A copy of this designation shall be furnished to the Contractor.\n\nThe contractor shall perform triennial testing during the base year to set the cyclic period for this requirement. Within thirty days after contract award, for base and option years, the contractor shall provide the VA with an annual inspection and testing schedule, distinguishing between yearly and triennial events. The estimated yearly schedule is subject to COR approval. The Contractor shall provide the COR a finalized schedule for each task 30 days before the intended inspection and testing to confirm the scheduled date is still acceptable.\n\nThe Contractor and any Subcontractor shall report to the COR when arriving to perform any service under this requirement, including repairs only at the Walla Walla location. The contractor shall call the COR and coordinate with the clinic manager when arriving at the VA clinic. Check-in/out is mandatory at VA Police to obtain temporary badge. When the service is completed, the Contractor and any Subcontractor shall check out with the COR as well.\n\nThe Contractor shall coordinate with the Subcontractor directly for any tasks associated with SOW. It is the responsibility of the Contractor to ensure Subcontractor performs all work in accordance with the SOW.\n\nDeliverables\n\nInspection/Testing Reports\n\nWhen inspections are completed at the end of each day before the field technician leaves the site, they are required to furnish a digital or electronic copy of their field testing notes to the COR.\n\nDeliver the final report to the COR no more than 30 days after completion of inspection and testing. This will be in electronic format.\n\nIf deficiencies are discovered during inspection and testing, the final report and the field testing notes are required to have a description of the system conditions, description of corrected measures needed and any other special notes (tests conducted and maintenance work that may need to be performed). The service technician signs and submits this form to the COR.\n\nAll services under this contract shall conform with the National Fire Protection Agency (NFPA), Occupational Safety and Health Administration (OSHA), and Original Equipment Manufacturer standards and specifications.\n\nInspection and Acceptance Criteria\n\nThe COR is responsible for monitoring and inspecting work performed under this contract is in accordance with the Statement of Work.\n\nThe Contractor and COR will work together to resolve deficiencies. Work not completed or not acceptable under general industry standards cannot be certified for payment.\n\nStandards and Qualifications\n\nGenerator Testing and Maintenance\n\nAll Generator Technicians shall have the experience and training to perform the work and hold a current license or certification for installation of the systems involved. They must be certified by Caterpillar Inc. (CAT) through their training programs or by official documentation.\n\nNumber of Employees. The Contractor shall always have available a sufficient number of capable and qualified employees to enable the contractor to properly, adequately, and safely perform all work required under the terms of this contract.\n\nLicenses & Permits. Contractor and subcontractor personnel engaged in the activities specified by this contract shall be also required to possess certificates of training, licenses, and permits as required by the state, county, parish, city, and other local jurisdictions.\n\nDocumentation. The Contractor shall provide to the Contracting Officer Representative (COR) or Contracting Officer Designee documentation of the certificates of training, licenses, and permits for all new employees not later than seven (7) days prior to that person beginning work under the terms of this contract. licenses, permits, and bonds are current and valid. All offers must include documentation and proof of the above certifications and qualifications for each employee.\n\nDamage to Generators: Any damage to the generator or associated equipment (e.g. fans, pumps, electrical switchgear) caused by normal testing shall be repaired by the Contractor at no additional cost to the Government. At its discretion, the Government may have representatives present to witness any or all such tests. All costs associated with this damage shall be borne by the Contractor.\n\nWork Hours\n\nNormal Work Hours are defined as Monday through Friday from 8 a.m. to 4:30 p.m., excluding federal holidays or as otherwise arranged with the COR. The COR will communicate with the Contractor if work, inspection, testing, repair, etc. is able to be scheduled during normal work hours.\n\nAfter Hours. The Contractor shall be required to perform some work, inspection, test, and repair outside the normal working hours of the building occupants or due to emergency conditions. Any scheduled work that is disruptive to the tenants during annual and triennial tests (generator noise or fumes from generator) shall be performed after the building occupant's normal working hours for the following generators: B86 Caterpillar/LC5, B86 Caterpillar C18, and B143 Caterpillar/L7C.\n\nThe holidays observed by the Federal Government are New Year's Day, Martin Luther King Day, President's Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day. Also, any other day declared by the President of the United States to be a national holiday.\n\nRisk Control\n\nThe Contractor shall comply with all applicable Federal, State, and local laws and regulations to include responsibility to conform by current Occupational, Safety, Health Administration (OSHA) & Environmental Protection Agency (EPA) regulations while working on this facility. Contractor shall comply with Walla Walla VA safety, security, and screening requirements.\n\nContractor is responsible for all reports required or requested by Federal, State and Local ordinances that pertain to any duties contained in the contract.\n\nAll Contractor employees must wear a reflective vest or suitable substitute approved by the COR.\n\nAll equipment operators shall yield to all pedestrians and traffic. All trucks that are hauling generator equipment must have proper company identification prominently displayed on them to inform facility police when they are conducting rounds.\n\nContractor shall take all precautions necessary to protect persons and property from injury or damage during the performance of this contract. Contractor shall be responsible for any injury to any Contractor s representative, or others, as well as for any damage to any personal or public property that occurs during the performance of this contract that is caused by the Contractor s fault or negligence.\n\nThe Government shall inform the Contractor of any known ACM in a generator enclosure. If the Contractor must disturb materials he suspects may contain ACM, the Contractor shall immediately report it to the Contracting Officer Representative (COR) or Contracting Officer Designee, and the Contracting Officer Representative (COR) or Contracting Officer Designee will investigate and instruct the Contractor how to avoid an airborne asbestos exposure.\n\nLead -Based Paint: The Government shall inform the Contractor of any known lead-based paint in a generator enclosure. If the Contractor must disturb materials he suspects may contain lead-based paint, the Contractor shall immediately report it to the Contracting Officer Representative (COR) or Contracting Officer Designee, and Contracting Officer Representative (COR) or Contracting Officer Designee will investigate and instruct the Contractor how to avoid lead-based paint contamination.\n\nHousekeeping. The Contractor shall leave areas where he performs work neat, clean and orderly.\n\nAll damage done by the Contractor shall become the Contractor s responsibility and expense.\n\nContractor and/or Sub-contractor shall not have any history of previous safety violations at the Walla Walla VA campus.\n\nSecurity Requirements\n\nFollowing contract award, the Contractor is required to present a list of personnel and their qualifications, to include a contract manager that will supervise the performance of this contract to the Contracting Officer. All supervisory Contractor personnel shall be able to communicate well with the COR or designee. All Contractor employees are subject to current Medical Center Directives applicable to their conduct.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI).\n\nNot applicable\n\nContract Administrator\n\nThe Contractor shall establish processes and assign appropriate resources to effectively administer the requirement. The Contract Administrator shall respond to Government requests for contractual actions in a timely fashion and take immediate action to correct any deficiencies found. The Contractor shall have a single point of contact between the Government and Contractor personnel assigned to support the contract. An alternate point of contact may be assigned at the approval of the Contracting Officer. The Contract Administrator shall attend Quarterly Meetings as described below.\n\nContract Administrator shall in-person attend Annual Inspection and supervise any contractor or subcontractor personnel. Contract Administrator shall meet with COR while on-site to discuss any pertinent inspection information, deficiencies, and/or future coordination items.\n\nContract Administrator shall be the main POC for Repairs and Rider work unless an Alternative POC is approved by the COR. The Contract Administrator will respond promptly to CFR and emergent requests and coordinate all aspects of the work diligently with any Contractor or Subcontractor personnel while informing the COR daily of status and coordinating further approval as applicable.\n\nContract Administrator shall ensure all submitted invoices are correct and verifiable in accordance with invoices procedures outlined.\n\nThe Contract Administrator and/or assigned alternate shall be able to communicate well with the COR or designee and respond within one (1) business day to COR and/or CO inquiries.\n\nDeliverable: Contractor shall provide Contract Administrator name, email, direct phone information and resume at quote submission and three (3) business days after change of personnel to the Contracting Officer and COR.\n\nMiscellaneous\n\nGovernment does not pay for services not received.\n\nAppendix A: Generator Inventory and Fuel Tank Locations\nGenerator Inventory\nLocation Building\nMake/Model\nVoltage\nRated KW\nLoad Testing Required\nB86\nCaterpillar/LC5\n208\n250\nYes\nB143 Outpatient Clinic\nCaterpillar/L7C\n480\n600\nYes\nB78 Theater\nJohn Deere/A75JFTL3\n208\n90\nYes\nB76 Boiler Plant\nCaterpillar/C7.1\n208\n260\nYes\nB140 RRU\nGenerac/13653720100\n480\n150\nYes\nB145 Specialty Care Clinic\nCaterpillar/LC5\n480\n175\nYes\nB74\nCummins QSB7\n480\n125\nYes\nB86\nCaterpillar/C18\n480\n600\nYes\nFuel Tank Inventory\nTank #\nBuilding\nLocation\nReason\nGallons\nQuantity\nAbove/Underground\n1\n76\nNext to Boiler Plant, behind double set of steel doors\nBoiler Contingency Fuel\n20,000\n2\nUnderground\n2\n76\nBehind 76 with set of double steel doors\nFuel for 76 Generator and 80 Generator\n6500\n1\nUnderground\n3\n78\nWest end of 78 covered by concrete pad\nFuel for 78 Generator\n1100\n1\nUnderground\n4\n86\nSouth end in walled enclosure\nFuel for Adjacent Generator\n480\n1\nAboveground\n5\n140\nWest side of building\nFuel for 140 Generator\n480\n1\nAboveground\n6\n143\nSoutheast corner of building in walled enclosure\nFuel for 143 Generator\n900\n1\nAboveground\n7\n145\nSouthwest corner of building in walled enclosure\nFuel for 145 Generator\n900\n1\nAboveground\n8\n86\nDouble walled integrated tank, south end of building\nFuel for Adjacent Generator\n380\n1\nAboveground\n9\n74\nRight next to generator in double walled tank\nFuel for Building Generator\n350\n1\nAboveground","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26026Q0462","place_of_performance":{"zip":"99362","city":{"name":"Walla Walla"},"state":{"name":"WA"},"street":"Jonathan M. Wainwright Memorial VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"77 Wainwright Dr."},"product_service_code":"H965"}],"due_at":"2026-03-23T19:00:00Z","due_date":"2026-03-23","closes_at":"2026-03-23T19:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","state":"WA","county":"53071","county_name":"Walla Walla County","city":"5375775","city_name":"Walla Walla","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-11T03:49:06.893925Z","principal_notice_id":"298ee6639d364f93bddb68faa1ed2871","description":{"text":"The Department of Veterans Affairs (VA), Network Contracting Office 20 (NCO 20), is conducting market research on behalf of the Walla Walla VAMC to identify potential contractors capable of providing generator and fuel testing services.\nTo be considered a responsive and potential source, interested parties shall provide a capabilities statement containing the following information:\nBusiness name, address, point of contact, phone number and email address.\nBusiness size designation (under NAICS 811310 sized standard $12.5M), type (SDVOSB, VOSB, WOSB or other), and SAM Unique Identifier Number\nAffirmation that the vendor is capable of performing in accordance with the attached Draft Performance Work Statement.\nAlso, vendors shall include at least one example of relevant past performance wherein it is shown the quoter has performed similar work meeting similar performance standards in the past.\nAffirmation that the vendor is capable of performing in compliance with the Limitations on Subcontracting, in accordance with VAAR 852.219-75, if this were to be set-aside for SD/VOSBs or other Small Businesses.\nAdditionally, contractors can provide feedback on the attached Draft Performance Work Statement, which may be considered if a solicitation is posted.\nProvide the requested information to Michael Allred at michael.allred1@va.gov before 12:00 PM PST on March 23rd, 2026. All questions must be submitted via email, no telephonic inquiries will be accepted.\nThis is a sources-sought notice only. The purpose of this notice is to obtain information regarding the availability and capability of ALL verified sources to include qualified SDVOSB/VOSB to perform this potential requirement. Responses received will assist the Government in determining the appropriate acquisition strategy. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time, and this is not a request for quotes.\nSee attached document: Draft Statement of Work.\n\nEB.3 STATEMENT OF WORK (SOW)\n\nTitle: Emergency Generator Load and Fuel Testing\n\nBackground\n\nThe Jonathan M Wainwright Memorial VA Medical Center (VAWW), located at 77 Wainwright Drive, Walla Walla, WA, requires annual and triennial testing of emergency generators as required by NFPA 110 and fuel testing per NFPA 110 Part 8.3.7. There are currently eight diesel electric generators on the VAWW campus which have insufficient connected load and require annual testing with a supplemental load bank. There are 9 fuel storage containers that need to be tested as well.\n\nPlace of Performance\n\nAll work under this contract is to be performed at the following locations:\n\nWalla Walla VA Medical Center, 77 Wainwright Dr, Walla Walla, WA 99362\n\nScope\n\nContractor shall furnish all labor, travel, equipment, supplies, and materials required to perform a complete inspection, testing, maintenance and repair service of the systems in accordance with the frequency and procedures outlined in the most current edition of the Applicable publications mentioned throughout all of the identified scope below.\n\nProvide annual inspections and supplemental load bank testing according to the following NFPA 110 and VA Directive 1028 language:\n\nIf the monthly EPSS tests cannot exercise the generators at 30 percent load or acceptable stack exhaust temperature, an annual test must be conducted using supplemental load banks. Such test must meet applicable requirements of NFPA 99, NFPA 110, and The Joint Commission.\n\nThe generator must be tested at 50% nameplate load for the first 30 minutes and then at 75% nameplate load for 60 minutes following the first 30 minutes. In total, the generator will be tested for 1.5 hours.\n\nProvide annual fuel testing per NFPA 110, generator manufacture s recommendations and ASTM testing standards to validate that the quality of fuel complies with manufacture s acceptable ranges for proper generator functionality.\n\nProvide triennial generator testing using supplemental load bank testing according to the following VA Directive 1028 and The Joint Commission language:\n\nThe Joint Commission requires a 4-hour generator test under load (dynamic or static) that is at least 30 percent of the nameplate rating of the generator once every 36 months. To accomplish this the VA requests that the generator is tested for 180 minutes at 30% of nameplate load and then tested for 60 minutes at 75% nameplate load.\nThe contractor will not perform annual tests during the same year that triennial tests are required. The VA has an agreement with NFPA that when triennial testing is performed to VA standards, NFPA accepts that our triennial testing as an annual test.\n\nAPPLICABLE PUBLICATIONS: The publications listed below shall be followed when engaging in any work required by this contract. There are specific references called out, but it is still expected that any requirements of these codes are followed. The most current edition of these standards shall be applicable.\n\nNational Fire Protection Association (NFPA):\nNFPA 110 Standard for Emergency and Standby Power Systems\nUnderwriters Laboratories, Inc. (UL)\nAmerican Society for Testing and Materials (ASTM) Including but not limited to:\nASTM D975\nThe Joint Commission (TJC) Environment of Care Manual\n\nNotification/Coordination\n\nUpon award the Contracting Officer (CO) may designate a Representative (COR) to supervise the work performed for the duration of this contract. However, in no event, will any understanding, agreement, modification, change order, or other matter deviating from the terms of the contract between the contractor and any person other than the CO be effective or binding upon the Government, unless formalized by proper contractual documents executed by the CO, prior to completion of this contract. A copy of this designation shall be furnished to the Contractor.\n\nThe contractor shall perform triennial testing during the base year to set the cyclic period for this requirement. Within thirty days after contract award, for base and option years, the contractor shall provide the VA with an annual inspection and testing schedule, distinguishing between yearly and triennial events. The estimated yearly schedule is subject to COR approval. The Contractor shall provide the COR a finalized schedule for each task 30 days before the intended inspection and testing to confirm the scheduled date is still acceptable.\n\nThe Contractor and any Subcontractor shall report to the COR when arriving to perform any service under this requirement, including repairs only at the Walla Walla location. The contractor shall call the COR and coordinate with the clinic manager when arriving at the VA clinic. Check-in/out is mandatory at VA Police to obtain temporary badge. When the service is completed, the Contractor and any Subcontractor shall check out with the COR as well.\n\nThe Contractor shall coordinate with the Subcontractor directly for any tasks associated with SOW. It is the responsibility of the Contractor to ensure Subcontractor performs all work in accordance with the SOW.\n\nDeliverables\n\nInspection/Testing Reports\n\nWhen inspections are completed at the end of each day before the field technician leaves the site, they are required to furnish a digital or electronic copy of their field testing notes to the COR.\n\nDeliver the final report to the COR no more than 30 days after completion of inspection and testing. This will be in electronic format.\n\nIf deficiencies are discovered during inspection and testing, the final report and the field testing notes are required to have a description of the system conditions, description of corrected measures needed and any other special notes (tests conducted and maintenance work that may need to be performed). The service technician signs and submits this form to the COR.\n\nAll services under this contract shall conform with the National Fire Protection Agency (NFPA), Occupational Safety and Health Administration (OSHA), and Original Equipment Manufacturer standards and specifications.\n\nInspection and Acceptance Criteria\n\nThe COR is responsible for monitoring and inspecting work performed under this contract is in accordance with the Statement of Work.\n\nThe Contractor and COR will work together to resolve deficiencies. Work not completed or not acceptable under general industry standards cannot be certified for payment.\n\nStandards and Qualifications\n\nGenerator Testing and Maintenance\n\nAll Generator Technicians shall have the experience and training to perform the work and hold a current license or certification for installation of the systems involved. They must be certified by Caterpillar Inc. (CAT) through their training programs or by official documentation.\n\nNumber of Employees. The Contractor shall always have available a sufficient number of capable and qualified employees to enable the contractor to properly, adequately, and safely perform all work required under the terms of this contract.\n\nLicenses & Permits. Contractor and subcontractor personnel engaged in the activities specified by this contract shall be also required to possess certificates of training, licenses, and permits as required by the state, county, parish, city, and other local jurisdictions.\n\nDocumentation. The Contractor shall provide to the Contracting Officer Representative (COR) or Contracting Officer Designee documentation of the certificates of training, licenses, and permits for all new employees not later than seven (7) days prior to that person beginning work under the terms of this contract. licenses, permits, and bonds are current and valid. All offers must include documentation and proof of the above certifications and qualifications for each employee.\n\nDamage to Generators: Any damage to the generator or associated equipment (e.g. fans, pumps, electrical switchgear) caused by normal testing shall be repaired by the Contractor at no additional cost to the Government. At its discretion, the Government may have representatives present to witness any or all such tests. All costs associated with this damage shall be borne by the Contractor.\n\nWork Hours\n\nNormal Work Hours are defined as Monday through Friday from 8 a.m. to 4:30 p.m., excluding federal holidays or as otherwise arranged with the COR. The COR will communicate with the Contractor if work, inspection, testing, repair, etc. is able to be scheduled during normal work hours.\n\nAfter Hours. The Contractor shall be required to perform some work, inspection, test, and repair outside the normal working hours of the building occupants or due to emergency conditions. Any scheduled work that is disruptive to the tenants during annual and triennial tests (generator noise or fumes from generator) shall be performed after the building occupant's normal working hours for the following generators: B86 Caterpillar/LC5, B86 Caterpillar C18, and B143 Caterpillar/L7C.\n\nThe holidays observed by the Federal Government are New Year's Day, Martin Luther King Day, President's Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day. Also, any other day declared by the President of the United States to be a national holiday.\n\nRisk Control\n\nThe Contractor shall comply with all applicable Federal, State, and local laws and regulations to include responsibility to conform by current Occupational, Safety, Health Administration (OSHA) & Environmental Protection Agency (EPA) regulations while working on this facility. Contractor shall comply with Walla Walla VA safety, security, and screening requirements.\n\nContractor is responsible for all reports required or requested by Federal, State and Local ordinances that pertain to any duties contained in the contract.\n\nAll Contractor employees must wear a reflective vest or suitable substitute approved by the COR.\n\nAll equipment operators shall yield to all pedestrians and traffic. All trucks that are hauling generator equipment must have proper company identification prominently displayed on them to inform facility police when they are conducting rounds.\n\nContractor shall take all precautions necessary to protect persons and property from injury or damage during the performance of this contract. Contractor shall be responsible for any injury to any Contractor s representative, or others, as well as for any damage to any personal or public property that occurs during the performance of this contract that is caused by the Contractor s fault or negligence.\n\nThe Government shall inform the Contractor of any known ACM in a generator enclosure. If the Contractor must disturb materials he suspects may contain ACM, the Contractor shall immediately report it to the Contracting Officer Representative (COR) or Contracting Officer Designee, and the Contracting Officer Representative (COR) or Contracting Officer Designee will investigate and instruct the Contractor how to avoid an airborne asbestos exposure.\n\nLead -Based Paint: The Government shall inform the Contractor of any known lead-based paint in a generator enclosure. If the Contractor must disturb materials he suspects may contain lead-based paint, the Contractor shall immediately report it to the Contracting Officer Representative (COR) or Contracting Officer Designee, and Contracting Officer Representative (COR) or Contracting Officer Designee will investigate and instruct the Contractor how to avoid lead-based paint contamination.\n\nHousekeeping. The Contractor shall leave areas where he performs work neat, clean and orderly.\n\nAll damage done by the Contractor shall become the Contractor s responsibility and expense.\n\nContractor and/or Sub-contractor shall not have any history of previous safety violations at the Walla Walla VA campus.\n\nSecurity Requirements\n\nFollowing contract award, the Contractor is required to present a list of personnel and their qualifications, to include a contract manager that will supervise the performance of this contract to the Contracting Officer. All supervisory Contractor personnel shall be able to communicate well with the COR or designee. All Contractor employees are subject to current Medical Center Directives applicable to their conduct.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI).\n\nNot applicable\n\nContract Administrator\n\nThe Contractor shall establish processes and assign appropriate resources to effectively administer the requirement. The Contract Administrator shall respond to Government requests for contractual actions in a timely fashion and take immediate action to correct any deficiencies found. The Contractor shall have a single point of contact between the Government and Contractor personnel assigned to support the contract. An alternate point of contact may be assigned at the approval of the Contracting Officer. The Contract Administrator shall attend Quarterly Meetings as described below.\n\nContract Administrator shall in-person attend Annual Inspection and supervise any contractor or subcontractor personnel. Contract Administrator shall meet with COR while on-site to discuss any pertinent inspection information, deficiencies, and/or future coordination items.\n\nContract Administrator shall be the main POC for Repairs and Rider work unless an Alternative POC is approved by the COR. The Contract Administrator will respond promptly to CFR and emergent requests and coordinate all aspects of the work diligently with any Contractor or Subcontractor personnel while informing the COR daily of status and coordinating further approval as applicable.\n\nContract Administrator shall ensure all submitted invoices are correct and verifiable in accordance with invoices procedures outlined.\n\nThe Contract Administrator and/or assigned alternate shall be able to communicate well with the COR or designee and respond within one (1) business day to COR and/or CO inquiries.\n\nDeliverable: Contractor shall provide Contract Administrator name, email, direct phone information and resume at quote submission and three (3) business days after change of personnel to the Contracting Officer and COR.\n\nMiscellaneous\n\nGovernment does not pay for services not received.\n\nAppendix A: Generator Inventory and Fuel Tank Locations\nGenerator Inventory\nLocation Building\nMake/Model\nVoltage\nRated KW\nLoad Testing Required\nB86\nCaterpillar/LC5\n208\n250\nYes\nB143 Outpatient Clinic\nCaterpillar/L7C\n480\n600\nYes\nB78 Theater\nJohn Deere/A75JFTL3\n208\n90\nYes\nB76 Boiler Plant\nCaterpillar/C7.1\n208\n260\nYes\nB140 RRU\nGenerac/13653720100\n480\n150\nYes\nB145 Specialty Care Clinic\nCaterpillar/LC5\n480\n175\nYes\nB74\nCummins QSB7\n480\n125\nYes\nB86\nCaterpillar/C18\n480\n600\nYes\nFuel Tank Inventory\nTank #\nBuilding\nLocation\nReason\nGallons\nQuantity\nAbove/Underground\n1\n76\nNext to Boiler Plant, behind double set of steel doors\nBoiler Contingency Fuel\n20,000\n2\nUnderground\n2\n76\nBehind 76 with set of double steel doors\nFuel for 76 Generator and 80 Generator\n6500\n1\nUnderground\n3\n78\nWest end of 78 covered by concrete pad\nFuel for 78 Generator\n1100\n1\nUnderground\n4\n86\nSouth end in walled enclosure\nFuel for Adjacent Generator\n480\n1\nAboveground\n5\n140\nWest side of building\nFuel for 140 Generator\n480\n1\nAboveground\n6\n143\nSoutheast corner of building in walled enclosure\nFuel for 143 Generator\n900\n1\nAboveground\n7\n145\nSouthwest corner of building in walled enclosure\nFuel for 145 Generator\n900\n1\nAboveground\n8\n86\nDouble walled integrated tank, south end of building\nFuel for Adjacent Generator\n380\n1\nAboveground\n9\n74\nRight next to generator in double walled tank\nFuel for Building Generator\n350\n1\nAboveground","html":"The Department of Veterans Affairs (VA), Network Contracting Office 20 (NCO 20), is conducting market research on behalf of the Walla Walla VAMC to identify potential contractors capable of providing generator and fuel testing services. \nTo be considered a responsive and potential source, interested parties shall provide a capabilities statement containing the following information: \nBusiness name, address, point of contact, phone number and email address. \nBusiness size designation (under NAICS 811310 sized standard $12.5M), type (SDVOSB, VOSB, WOSB or other), and SAM Unique Identifier Number \nAffirmation that the vendor is capable of performing in accordance with the attached Draft Performance Work Statement. \nAlso, vendors shall include at least one example of relevant past performance wherein it is shown the quoter has performed similar work meeting similar performance standards in the past. \nAffirmation that the vendor is capable of performing in compliance with the Limitations on Subcontracting, in accordance with VAAR 852.219-75,  if this were to be set-aside for SD/VOSBs or other Small Businesses.\nAdditionally, contractors can provide feedback on the attached Draft Performance Work Statement, which may be considered if a solicitation is posted. \nProvide the requested information to Michael Allred at michael.allred1@va.gov before 12:00 PM PST on March 23rd, 2026. All questions must be submitted via email, no telephonic inquiries will be accepted.\nThis is a sources-sought notice only. The purpose of this notice is to obtain information regarding the availability and capability of ALL verified sources to include qualified SDVOSB/VOSB to perform this potential requirement. Responses received will assist the Government in determining the appropriate acquisition strategy. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time, and this is not a request for quotes.\nSee attached document: Draft Statement of Work.\n \nEB.3 STATEMENT OF WORK (SOW)\n\nTitle: Emergency Generator Load and Fuel Testing\n\nBackground\n\nThe Jonathan M Wainwright Memorial VA Medical Center (VAWW), located at 77 Wainwright Drive, Walla Walla, WA, requires annual and triennial testing of emergency generators as required by NFPA 110 and fuel testing per NFPA 110 Part 8.3.7. There are currently eight diesel electric generators on the VAWW campus which have insufficient connected load and require annual testing with a supplemental load bank. There are 9 fuel storage containers that need to be tested as well.  \n\nPlace of Performance\n\nAll work under this contract is to be performed at the following locations: \n\nWalla Walla VA Medical Center, 77 Wainwright Dr, Walla Walla, WA 99362\n\nScope \n\nContractor shall furnish all labor, travel, equipment, supplies, and materials required to perform a complete inspection, testing, maintenance and repair service of the systems in accordance with the frequency and procedures outlined in the most current edition of the Applicable publications mentioned throughout all of the identified scope below.\n\nProvide annual inspections and supplemental load bank testing according to the following NFPA 110 and VA Directive 1028 language:\n\nIf the monthly EPSS tests cannot exercise the generators at 30 percent load or acceptable stack exhaust temperature, an annual test must be conducted using supplemental load banks. Such test must meet applicable requirements of NFPA 99, NFPA 110, and The Joint Commission.\n\nThe generator must be tested at 50% nameplate load for the first 30 minutes and then at 75% nameplate load for 60 minutes following the first 30 minutes. In total, the generator will be tested for 1.5 hours.\n\nProvide annual fuel testing per NFPA 110, generator manufacture s recommendations and ASTM testing standards to validate that the quality of fuel complies with manufacture s acceptable ranges for proper generator functionality.\n\nProvide triennial generator testing using supplemental load bank testing according to the following VA Directive 1028 and The Joint Commission language:\n\nThe Joint Commission requires a 4-hour generator test under load (dynamic or static) that is at least 30 percent of the nameplate rating of the generator once every 36 months. To accomplish this the VA requests that the generator is tested for 180 minutes at 30% of nameplate load and then tested for 60 minutes at 75% nameplate load.\nThe contractor will not perform annual tests during the same year that triennial tests are required. The VA has an agreement with NFPA that when triennial testing is performed to VA standards, NFPA accepts that our triennial testing as an annual test.\n\nAPPLICABLE PUBLICATIONS: The publications listed below shall be followed when engaging in any work required by this contract. There are specific references called out, but it is still expected that any requirements of these codes are followed. The most current edition of these standards shall be applicable. \n\nNational Fire Protection Association (NFPA): \nNFPA 110 Standard for Emergency and Standby Power Systems\nUnderwriters  Laboratories, Inc. (UL)\nAmerican Society for Testing and Materials (ASTM) Including but not limited to:\nASTM D975\nThe Joint Commission (TJC) Environment of Care Manual\n\nNotification/Coordination\n\nUpon award the Contracting Officer (CO) may designate a Representative (COR) to supervise the work performed for the duration of this contract. However, in no event, will any understanding, agreement, modification, change order, or other matter deviating from the terms of the contract between the contractor and any person other than the CO be effective or binding upon the Government, unless formalized by proper contractual documents executed by the CO, prior to completion of this contract. A copy of this designation shall be furnished to the Contractor.\n\nThe contractor shall perform triennial testing during the base year to set the cyclic period for this requirement. Within thirty days after contract award, for base and option years, the contractor shall provide the VA with an annual inspection and testing schedule, distinguishing between yearly and triennial events. The estimated yearly schedule is subject to COR approval. The Contractor shall provide the COR a finalized schedule for each task 30 days before the intended inspection and testing to confirm the scheduled date is still acceptable.\n\nThe Contractor and any Subcontractor shall report to the COR when arriving to perform any service under this requirement, including repairs only at the Walla Walla location. The contractor shall call the COR and coordinate with the clinic manager when arriving at the VA clinic. Check-in/out is mandatory at VA Police to obtain temporary badge.  When the service is completed, the Contractor and any Subcontractor shall check out with the COR as well.\n\nThe Contractor shall coordinate with the Subcontractor directly for any tasks associated with SOW. It is the responsibility of the Contractor to ensure Subcontractor performs all work in accordance with the SOW.\n\nDeliverables\n\nInspection/Testing Reports\n\nWhen inspections are completed at the end of each day before the field technician leaves the site, they are required to furnish a digital or electronic copy of their field testing notes to the COR. \n\nDeliver the final report to the COR no more than 30 days after completion of inspection and testing.  This will be in electronic format.\n\nIf deficiencies are discovered during inspection and testing, the final report and the field testing notes are required to have a description of the system conditions, description of corrected measures needed and any other special notes (tests conducted and maintenance work that may need to be performed). The service technician signs and submits this form to the COR.  \n\nAll services under this contract shall conform with the National Fire Protection Agency (NFPA), Occupational Safety and Health Administration (OSHA), and Original Equipment Manufacturer standards and specifications.\n\nInspection and Acceptance Criteria  \n\nThe COR is responsible for monitoring and inspecting  work performed  under this contract is in accordance with the Statement of Work. \n\nThe Contractor and COR will work together to resolve deficiencies. Work not completed or not acceptable under general industry standards cannot be certified for payment. \n\n\nStandards and Qualifications\n\nGenerator Testing and Maintenance\n\nAll Generator Technicians shall have the experience and training to perform the work and hold a current license or certification for installation of the systems involved. They must be certified by Caterpillar Inc. (CAT) through their training programs or by official documentation. \n\nNumber of Employees. The Contractor shall always have available a sufficient number of capable and qualified employees to enable the contractor to properly, adequately, and safely perform all work required under the terms of this contract.\n\nLicenses & Permits. Contractor and subcontractor personnel engaged in the activities specified by this contract shall be also required to possess certificates of training, licenses, and permits as required by the state, county, parish, city, and other local jurisdictions.\n\nDocumentation. The Contractor shall provide to the Contracting Officer Representative (COR) or Contracting Officer Designee documentation of the certificates of training, licenses, and permits for all new employees not later than seven (7) days prior to that person beginning work under the terms of this contract. licenses, permits, and bonds are current and valid.  All offers must include documentation and proof of the above certifications and qualifications for each employee.\n\nDamage to Generators:  Any damage to the generator or associated equipment (e.g. fans, pumps, electrical switchgear) caused by normal testing shall be repaired by the Contractor at no additional cost to the Government. At its discretion, the Government may have representatives present to witness any or all such tests. All costs associated with this damage shall be borne by the Contractor.\n\nWork Hours\n\nNormal Work Hours are defined as Monday through Friday from 8 a.m. to 4:30 p.m., excluding federal holidays or as otherwise arranged with the COR.  The COR will communicate with the Contractor if work, inspection, testing, repair, etc. is able to be scheduled during normal work hours. \n\nAfter Hours. The Contractor shall be required to perform some work, inspection, test, and repair outside the normal working hours of the building occupants or due to emergency conditions.  Any scheduled work that is disruptive to the tenants during annual and triennial tests (generator noise or fumes from generator) shall be performed after the building occupant's normal working hours for the following generators: B86 Caterpillar/LC5, B86 Caterpillar C18, and B143 Caterpillar/L7C.\n\nThe holidays observed by the Federal Government are New Year's Day, Martin Luther King Day, President's Day, Memorial Day, Juneteenth, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, and Christmas Day.  Also, any other day declared by the President of the United States to be a national holiday.\n\nRisk Control\n\nThe Contractor shall comply with all applicable Federal, State, and local laws and regulations to include responsibility to conform by current Occupational, Safety, Health Administration (OSHA) & Environmental Protection Agency (EPA) regulations while working on this facility. Contractor shall comply with Walla Walla VA safety, security, and screening requirements.\n\nContractor is responsible for all reports required or requested by Federal, State and Local ordinances that pertain to any duties contained in the contract.\n\nAll Contractor employees must wear a reflective vest or suitable substitute approved by the COR. \n\nAll equipment operators shall yield to all pedestrians and traffic. All trucks that are hauling generator equipment must have proper company identification prominently displayed on them to inform facility police when they are conducting rounds.\n\nContractor shall take all precautions necessary to protect persons and property from injury or damage during the performance of this contract. Contractor shall be responsible for any injury to any Contractor s representative, or others, as well as for any damage to any personal or public property that occurs during the performance of this contract that is caused by the Contractor s fault or negligence.\n\nThe Government shall inform the Contractor of any known ACM in a generator enclosure. If the Contractor must disturb materials he suspects may contain ACM, the Contractor shall immediately report it to the Contracting Officer Representative (COR) or Contracting Officer Designee, and the Contracting Officer Representative (COR) or Contracting Officer Designee will investigate and instruct the Contractor how to avoid an airborne asbestos exposure.\n\nLead -Based Paint: The Government shall inform the Contractor of any known lead-based paint in a generator enclosure. If the Contractor must disturb materials he suspects may contain lead-based paint, the Contractor shall immediately report it to the Contracting Officer Representative (COR) or Contracting Officer Designee, and Contracting Officer Representative (COR) or Contracting Officer Designee will investigate and instruct the Contractor how to avoid lead-based paint contamination.\n\nHousekeeping. The Contractor shall leave areas where he performs work neat, clean and orderly.\n\nAll damage done by the Contractor shall become the Contractor s responsibility and expense.\n\nContractor and/or Sub-contractor shall not have any history of previous safety violations at the Walla Walla VA campus.  \n\nSecurity Requirements\n\nFollowing contract award, the Contractor is required to present a list of personnel and their qualifications, to include a contract manager that will supervise the performance of this contract to the Contracting Officer. All supervisory Contractor personnel shall be able to communicate well with the COR or designee. All Contractor employees are subject to current Medical Center Directives applicable to their conduct.\n\nGovernment-Furnished Equipment (GFE)/Government-Furnished Information (GFI). \n\nNot applicable\n\nContract Administrator\n\nThe Contractor shall establish processes and assign appropriate resources to effectively administer the requirement. The Contract Administrator shall respond to Government requests for contractual actions in a timely fashion and take immediate action to correct any deficiencies found. The Contractor shall have a single point of contact between the Government and Contractor personnel assigned to support the contract. An alternate point of contact may be assigned at the approval of the Contracting Officer. The Contract Administrator shall attend Quarterly Meetings as described below. \n\nContract Administrator shall in-person attend Annual Inspection and supervise any contractor or subcontractor personnel. Contract Administrator shall meet with COR while on-site to discuss any pertinent inspection information, deficiencies, and/or future coordination items. \n\nContract Administrator shall be the main POC for Repairs and Rider work unless an Alternative POC is approved by the COR. The Contract Administrator will respond promptly to CFR and emergent requests and coordinate all aspects of the work diligently with any Contractor or Subcontractor personnel while informing the COR daily of status and coordinating further approval as applicable. \n\nContract Administrator shall ensure all submitted invoices are correct and verifiable in accordance with invoices procedures outlined. \n\nThe Contract Administrator and/or assigned alternate shall be able to communicate well with the COR or designee and respond within one (1) business day to COR and/or CO inquiries.\n\nDeliverable: Contractor shall provide Contract Administrator name, email, direct phone information and resume at quote submission and three (3) business days after change of personnel to the Contracting Officer and COR. \n\n\nMiscellaneous\n\nGovernment does not pay for services not received.\n\n\nAppendix A: Generator Inventory and Fuel Tank Locations\nGenerator Inventory\nLocation   Building\nMake/Model\nVoltage\nRated KW\nLoad Testing Required\nB86\nCaterpillar/LC5\n208\n250\nYes\nB143   Outpatient Clinic\nCaterpillar/L7C\n480\n600\nYes\nB78   Theater\nJohn Deere/A75JFTL3\n208\n90\nYes\nB76   Boiler Plant\nCaterpillar/C7.1\n208\n260\nYes\nB140   RRU\nGenerac/13653720100\n480\n150\nYes\nB145   Specialty Care Clinic\nCaterpillar/LC5\n480\n175\nYes\nB74\nCummins QSB7\n480\n125\nYes\nB86\nCaterpillar/C18\n480\n600\nYes\nFuel Tank Inventory\nTank #\nBuilding\nLocation\nReason\nGallons\nQuantity\nAbove/Underground\n1\n76\nNext to Boiler Plant, behind double set of steel doors\nBoiler Contingency Fuel\n20,000\n2\nUnderground\n2\n76\nBehind 76 with set of double steel doors\nFuel for 76 Generator and 80 Generator\n6500\n1\nUnderground\n3\n78\nWest end of 78 covered by concrete pad\nFuel for 78 Generator\n1100\n1\nUnderground\n4\n86\nSouth end in walled enclosure\nFuel for Adjacent Generator\n480\n1\nAboveground\n5\n140\nWest side of building\nFuel for 140 Generator\n480\n1\nAboveground\n6\n143\nSoutheast corner of building in walled enclosure\nFuel for 143 Generator\n900\n1\nAboveground\n7\n145\nSouthwest corner of building in walled enclosure\nFuel for 145 Generator\n900\n1\nAboveground\n8\n86\nDouble walled integrated tank, south end of building\nFuel for Adjacent Generator\n380\n1\nAboveground\n9\n74\nRight next to generator in double walled tank\nFuel for Building Generator\n350\n1\nAboveground","origin":"detail"},"contacts":[{"name":"Michael Allred","role":"primary","email":"michael.allred1@va.gov","phone":"5093211906","title":"Contracting Officer"}],"place_of_performance":{"zip":"99362","city":{"name":"Walla Walla"},"state":{"name":"WA"},"street":"Jonathan M. Wainwright Memorial VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"77 Wainwright Dr."},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"08695678f4ac458d9b63f03f3d9780d0","name":"36C26026Q0462_1.docx","kind":"file","mime_type":".docx","size_bytes":37575,"posted_at":"2026-03-16T21:50:30.649Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/08695678f4ac458d9b63f03f3d9780d0/download","mirrored":false}],"awards":[],"related":[{"key":"36C26027R00020006","latest_notice_id":"299fab9bad854b0786fcc742e3f934d5","title":"Amendment 0006 to Provide Official RFI Responses, Update Solicitation Documents, Extend Proposal Due Date, & other Official Information","solicitation_number":"36C26027R0002-0006","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26027Q0117","latest_notice_id":"b6d17aea5ceb4b8d988004142043a40b","title":"6550 Reagents Consumables Microbiology Testing Boise VAMC","solicitation_number":"36C26027Q0117","notice_type":"r","first_type":"r","first_posted":"2026-11-09","last_posted":"2026-11-09","notices":1,"due_at":"2026-11-28T01:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"325413","psc":"6550","set_aside":null,"state":"ID","county":"16001","county_name":"Ada County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Boise VA Medical Center","site_key":"boise-va-medical-center-id","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"36C26026Q0981","latest_notice_id":"f9240f8b1e9a4da7aa654200bac827aa","title":"WSNC Medical Coding Books","solicitation_number":"36C26026Q0981","notice_type":"o","first_type":"o","first_posted":"2026-10-08","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-01T18:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"513130","psc":"7610","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26027R00020007","latest_notice_id":"9c90cd15f29d407c9ea106c281373e63","title":"Y1DA--CON NRM 531-25-102 | Expand Emergency Room","solicitation_number":"36C26027R0002-0007","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"W912EF27QA006","latest_notice_id":"7c3b9228948945cbab4a7f0b98539397","title":"LLA Fish Pump - Motor Rewind","solicitation_number":"W912EF27QA006","notice_type":"k","first_type":"k","first_posted":"2026-10-22","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EF","office_name":"US ARMY ENGINEER DISTRICT WALLA WAL","naics":"811310","psc":"J043","set_aside":null,"state":"WA","county":"53023","county_name":"Garfield County","city":"5355120","city_name":"Pomeroy","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"FA462027QA205","latest_notice_id":"54f6ff4a5460436aa5e46579e3bd3d5d","title":"PAINT/SANDING BOOTH, AIR SHOWER, & CABINET BLASTER MAINTENANCE","solicitation_number":"FA462027QA205","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-15T18:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4620","office_name":"FA4620 92 CONS LGC","naics":"811310","psc":"J049","set_aside":"SBA","state":"WA","county":"53063","county_name":"Spokane County","city":"5322955","city_name":"Fairchild AFB","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C25627Q0131","latest_notice_id":"c34b2da547fb4d8fb1ceaf2fb177c660","title":"J012--Kitchen Exhaust Cleaning, Kitchen Fire Suppression System Service, and Portable Fire Extinguisher Service","solicitation_number":"36C25627Q0131","notice_type":"r","first_type":"r","first_posted":"2026-11-05","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-25T16:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"811310","psc":"J012","set_aside":null,"state":"AR","county":"05119","county_name":"Pulaski County","city":"0550450","city_name":"North Little Rock","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":58,"indexable":false}