{"canonical":"https://sealedbidder.com/opportunities/36c26025q0621","key":"36C26025Q0621","url":"https://sealedbidder.com/opportunities/36c26025q0621","title":"J041--Seattle Chiller System Maintenance Services","solicitation_number":"36C26025Q0621","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-07-10T22:00:00Z","first_posted":"2025-07-18","last_posted":"2025-07-18","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"811310","psc":"J041","set_aside":null,"place_state":"WA","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"53033","place_county_name":"King County","place_city":"5363000","place_city_name":"Seattle","winner":null,"award_amount":null,"publications":[{"notice_id":"c07d4f6b7584439f88d262a5cf97e186","title":"J041--Seattle Chiller System Maintenance Services","solicitation_number":"36C26025Q0621","notice_type":"r","base_type":"r","posted":"2025-07-18","posted_at":"2025-07-18T23:20:58.490Z","due_at":"2025-07-10T22:00:00Z","due_date":"2025-07-10","cancelled":false,"archived":true,"archive_date":"2025-08-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c07d4f6b7584439f88d262a5cf97e186/view","enriched":true,"history":[{"index":3,"title":"J041--Seattle Chiller System Maintenance Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-18T23:20:58.490Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c07d4f6b7584439f88d262a5cf97e186","solicitation_number":"36C26025Q0621"}]}],"latest_notice_id":"c07d4f6b7584439f88d262a5cf97e186","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-07-18","posted_at":"2025-07-18T23:20:58.490Z","created_at":"2025-07-18T23:20:56.333Z","modified_at":"2025-08-10T03:55:47.943Z","response_deadline":{"raw":"2025-07-10T15:00:00-07:00","utc":"2025-07-10T22:00:00Z","date":"2025-07-10","time":"15:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c07d4f6b7584439f88d262a5cf97e186/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J041--Seattle Chiller System Maintenance Services","agency":{"office":{"code":"36C260","name":"260-NETWORK CONTRACT OFFICE 20 (36C260)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"organization_id":"100186526","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-08-09","archive_type":"auto_custom"},"history":[{"index":3,"title":"J041--Seattle Chiller System Maintenance Services","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-07-18T23:20:58.490Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"c07d4f6b7584439f88d262a5cf97e186","solicitation_number":"36C26025Q0621"}],"contacts":[{"name":"Derek Crockett","role":"primary","email":"Derek.Crockett@va.gov","phone":"360-816-2760 x32760","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"c07d4f6b7584439f88d262a5cf97e186","lineage_id":"c07d4f6b7584439f88d262a5cf97e186","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-09T02:36:27.481059999Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"69f5c74c8ef260baae0d5f3283ee5a9238b3534f6920684257f344c37299c9b7","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-09T02:36:27.481059999Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"DESCRIPTION\nTHIS IS A REQUEST FOR INFORMATION ONLY.  This is not a solicitation for bids, proposals, proposal abstracts, or quotations.  The purpose of this sources sought to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement.  The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services:\n\nProposed NAICS Code 811310. Any questions or concerns may be directed to Derek Crockett via e-mail at derek.crockett@va.gov.\n\nRESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS:  \n1.) Company name, address, and business size; point of contact name, phone number, and e-mail address.\n2.)  Is your firm eligible for participation in one of the following small business programs?  If so, please indicate the program and the anticipated North American Industry Classification System (NAICS) code. \n\n[  ] yes   [  ] no     Small Business (SB) \n[  ] yes   [  ] no     HUBZone \n[  ] yes   [  ] no     Small Business 8(a) \n[  ] yes   [  ] no     Small Disadvantaged Business (SDB) \n[  ] yes   [  ] no     Women-Owned (WO) Small Business\n[  ] yes   [  ] no     Service Disabled Veteran Owned Small Business (SDVOSB)\n[  ] yes   [  ] no     Veteran Owned Small Business (VOSB) \n[  ] yes   [  ] no     Other (please specify) \n\n3.) Can you provide firm-fixed-pricing for the scope of services and supplies outlined in the Draft SOW below and for a period of five years?\n\n4.) Does your firm have staff with industry relevant industry certificates and Washington State credentials and/or licenses such as those detailed below? If yes, please list what certifications and licenses your firm and staff currently holds. \n\n5.) Does your firm have any existing contracts with the federal government or specific government agencies? (GSA, FSS, ect). If yes, please list the contract number(s) and agency contracts. \n\n6.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement?\n\n7.) Please provide a capability statement (not to exceed 5 pages) detailing any current or historical projects for similar requirements.\n\nDRAFT STATEMENT OF WORK (SOW):\nSTATEMENT OF WORK (SOW)\nas of 12/Feb/2025\n\n\n1.  Contract Title.  Annual Chiller Maintenance for SEA Energy Plant\n2.  Background.  \nThe Seattle VA has a large complicated chilled water system consisting of 4 water cooled 825 ton centrifugal chillers and 4 matching two cell counter-flow condenser water cooling towers. This system is used to create chilled water that is pumped throughout the campus to air handler cooling coils that cool and dehumidify air that is circulated throughout our buildings to cool people and equipment. The maintenance requirements for this equipment is specific and time consuming. At this time the existing Seattle VA Energy Plant operating staff do not have the manpower to conduct this extensive maintenance activity.\n3.  Scope. \n\nThe scope is for a contractor to provide annual maintenance on our chillers, cooling towers, and condenser water pumps per the specific tasks and schedule listed below. Contractor located no further than 50 miles of Seattle VAMC and must be able to respond to an emergency call within one hour.\n\n4. Specific Tasks.  \n\nEquipment Information:\nFour 825 Ton JCI/York model YKKCKQH9-EUG water cooled centrifugal chillers\nFour 2 cell Marley model MD5010QAF2L counter flow cooling towers\nSix 30 horsepower Baldor motors powering Grundfos condenser water pumps\nThree 150 horsepower Baldor motors powering Grundfos chilled water pumps\n\nThe Annual Equipment Inspection and PM:\n\nChecking the Compressor-Motor Assembly for the following items and performing PM Tasks as indicated:\n Recording voltages\n Megging and recording motor winding resistance\n Lubricating open motor\n Checking the alignment on open drive units\n Checking the coupling\n Checking seals\n Checking inlet vane operator and linkage; lubricating where required\n  \nChecking the Compressor Oil System for the following items:\n Changing oil filter, and dryer\n Conducting analysis on oil at an independent laboratory\n Checking oil pump, seal and motor\n Checking heater and thermostat\n Checking all other oil system components including cooler, strainer and solenoid valve   where  applicable\n  \nReview the Control Panel for the following items:\n Running diagnostic check of Optiview Control Panel\n Checking safety shutdown operation\n Checking all terminals and tightening connections\n Checking Display Data accuracy and set points\n  \nChecking the Condenser for the following items:\n Checking the water flow\n Checking flow switch operation\n Removing condenser head and inspecting end sheets\n \nChecking the Cooler for the following items:\n Checking the water flow\n Checking flow switch operation\n Checking refrigerant level\n \nChecking the System for the following items:\n Conducting a leak check and identifying leak sources for repairs\n Adding refrigerant as required (refrigerant provided by owner)\n Recording condition of sight glasses\n Checking the refrigerant cycle to verify the proper operating balance\n Checking condenser water and chilled water heat transfer\n  \nGeneral items included:\n Repairing insulation removed for inspection and maintenance procedures\n Cleaning equipment and surrounding area upon completion of work\n Consulting with the operator\n Reporting deficiencies and repairs required\n \nYORK VSD\n Record all power and control voltages for proper operation of drive\n Verify proper operation of cooling circuit and backflush heat exchanger (VSD only)\n Change closed loop coolant fluid every year\n Check condenser water loop strainer (VSD only)\n Check vane pot calibration and recalibrate when required\n  \nScope of Maintenance Cooling Tower Service Performed:\n  Clean pan (basin) strainer\n Clean and flush pan (basin)\n Check bleed off to make sure it is operative\n Check and adjust water level in cold water basin\n Clean water distribution system and spray nozzles\n Check drift eliminators for plugging\n Ensure that all fan hardware is tight and inspect fan for cracks\n Lubricate fan-shaft bearings and drive train\n Install new fan belts (if applicable) \n Lubricate motor-base-adjusting screw\n Ensure proper operation of all drive components\n Check and record amp draw on fan motor\n Clean air-inlet louvers as good as possible without causing damage\n Pressure wash interior of tower to remove any algae\n Inspect for rust and leaks and repair minor leaks\n Inspect vibration switch and adjust sensitivity if needed\n Inspect sweeper piping for cracks and plugging \n \nPumps (9) total\nPump strainer cleaning and pump maintenance and vibration analysis Isolation valve must be present and functioning Assuming 1 evaporator and 1 condenser per chiller \nInspect pump seals and replace/repair where needed. \n5. Performance Monitoring (if applicable).\nThe contractor will be monitored by the COR and Energy Plant operator staff on a daily basis and the contractor will submit a maintenance report showing the date and what work was completed.\n7. Security Requirements.\n\nThe contractor employees shall not have access to VA sensitive or computer information and will not require routine access to VA Facilities.  The contractor employees shall require intermittent access only and will be escorted by VA employees while at VA Facilities. No background investigation is required\nThe COR and Energy Plant Operating staff will inspect the maintenance activities as they are performed and accept the work before equipment can be closed up and put back in service.\n8. Risk Control\nTo avoid interrupting patient care, this work will be scheduled per the period of performance such that it will only be performed when the cooling load is low enough that multiple chillers are not required.\n9.  Place of Performance. \nThe work will be performed at the Energy Plant section of Building 100 at the Seattle Division of the VA Puget Sound Health Care System, 1660 S Columbian Way, Seattle, WA 98108.\n 11.  Period of Performance. \nThe maintenance work for Chillers and Cooling Tower 1   3 shall occur between the months of October to March. The maintenance work for Chiller and Cooling Tower 4 shall occur between the months of April to September. \n12.  Delivery Schedule. \n\nThe contract shall submit a maintenance report detailing the work performed and any special notes on the condition of the equipment. The report shall detail the date that the maintenance was performed and the amount of time to conduct it.\n\nEND OF DRAFT STATEMENT OF WORK","text":"DESCRIPTION\nTHIS IS A REQUEST FOR INFORMATION ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this sources sought to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services:\n\nProposed NAICS Code 811310. Any questions or concerns may be directed to Derek Crockett via e-mail at derek.crockett@va.gov.\n\nRESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS:\n1.) Company name, address, and business size; point of contact name, phone number, and e-mail address.\n2.) Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program and the anticipated North American Industry Classification System (NAICS) code.\n\n[ ] yes [ ] no Small Business (SB)\n[ ] yes [ ] no HUBZone\n[ ] yes [ ] no Small Business 8(a)\n[ ] yes [ ] no Small Disadvantaged Business (SDB)\n[ ] yes [ ] no Women-Owned (WO) Small Business\n[ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB)\n[ ] yes [ ] no Veteran Owned Small Business (VOSB)\n[ ] yes [ ] no Other (please specify)\n\n3.) Can you provide firm-fixed-pricing for the scope of services and supplies outlined in the Draft SOW below and for a period of five years?\n\n4.) Does your firm have staff with industry relevant industry certificates and Washington State credentials and/or licenses such as those detailed below? If yes, please list what certifications and licenses your firm and staff currently holds.\n\n5.) Does your firm have any existing contracts with the federal government or specific government agencies? (GSA, FSS, ect). If yes, please list the contract number(s) and agency contracts.\n\n6.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement?\n\n7.) Please provide a capability statement (not to exceed 5 pages) detailing any current or historical projects for similar requirements.\n\nDRAFT STATEMENT OF WORK (SOW):\nSTATEMENT OF WORK (SOW)\nas of 12/Feb/2025\n\n1. Contract Title. Annual Chiller Maintenance for SEA Energy Plant\n2. Background.\nThe Seattle VA has a large complicated chilled water system consisting of 4 water cooled 825 ton centrifugal chillers and 4 matching two cell counter-flow condenser water cooling towers. This system is used to create chilled water that is pumped throughout the campus to air handler cooling coils that cool and dehumidify air that is circulated throughout our buildings to cool people and equipment. The maintenance requirements for this equipment is specific and time consuming. At this time the existing Seattle VA Energy Plant operating staff do not have the manpower to conduct this extensive maintenance activity.\n3. Scope.\n\nThe scope is for a contractor to provide annual maintenance on our chillers, cooling towers, and condenser water pumps per the specific tasks and schedule listed below. Contractor located no further than 50 miles of Seattle VAMC and must be able to respond to an emergency call within one hour.\n\n4. Specific Tasks.\n\nEquipment Information:\nFour 825 Ton JCI/York model YKKCKQH9-EUG water cooled centrifugal chillers\nFour 2 cell Marley model MD5010QAF2L counter flow cooling towers\nSix 30 horsepower Baldor motors powering Grundfos condenser water pumps\nThree 150 horsepower Baldor motors powering Grundfos chilled water pumps\n\nThe Annual Equipment Inspection and PM:\n\nChecking the Compressor-Motor Assembly for the following items and performing PM Tasks as indicated:\nRecording voltages\nMegging and recording motor winding resistance\nLubricating open motor\nChecking the alignment on open drive units\nChecking the coupling\nChecking seals\nChecking inlet vane operator and linkage; lubricating where required\n\nChecking the Compressor Oil System for the following items:\nChanging oil filter, and dryer\nConducting analysis on oil at an independent laboratory\nChecking oil pump, seal and motor\nChecking heater and thermostat\nChecking all other oil system components including cooler, strainer and solenoid valve where applicable\n\nReview the Control Panel for the following items:\nRunning diagnostic check of Optiview Control Panel\nChecking safety shutdown operation\nChecking all terminals and tightening connections\nChecking Display Data accuracy and set points\n\nChecking the Condenser for the following items:\nChecking the water flow\nChecking flow switch operation\nRemoving condenser head and inspecting end sheets\n\nChecking the Cooler for the following items:\nChecking the water flow\nChecking flow switch operation\nChecking refrigerant level\n\nChecking the System for the following items:\nConducting a leak check and identifying leak sources for repairs\nAdding refrigerant as required (refrigerant provided by owner)\nRecording condition of sight glasses\nChecking the refrigerant cycle to verify the proper operating balance\nChecking condenser water and chilled water heat transfer\n\nGeneral items included:\nRepairing insulation removed for inspection and maintenance procedures\nCleaning equipment and surrounding area upon completion of work\nConsulting with the operator\nReporting deficiencies and repairs required\n\nYORK VSD\nRecord all power and control voltages for proper operation of drive\nVerify proper operation of cooling circuit and backflush heat exchanger (VSD only)\nChange closed loop coolant fluid every year\nCheck condenser water loop strainer (VSD only)\nCheck vane pot calibration and recalibrate when required\n\nScope of Maintenance Cooling Tower Service Performed:\nClean pan (basin) strainer\nClean and flush pan (basin)\nCheck bleed off to make sure it is operative\nCheck and adjust water level in cold water basin\nClean water distribution system and spray nozzles\nCheck drift eliminators for plugging\nEnsure that all fan hardware is tight and inspect fan for cracks\nLubricate fan-shaft bearings and drive train\nInstall new fan belts (if applicable)\nLubricate motor-base-adjusting screw\nEnsure proper operation of all drive components\nCheck and record amp draw on fan motor\nClean air-inlet louvers as good as possible without causing damage\nPressure wash interior of tower to remove any algae\nInspect for rust and leaks and repair minor leaks\nInspect vibration switch and adjust sensitivity if needed\nInspect sweeper piping for cracks and plugging\n\nPumps (9) total\nPump strainer cleaning and pump maintenance and vibration analysis Isolation valve must be present and functioning Assuming 1 evaporator and 1 condenser per chiller\nInspect pump seals and replace/repair where needed.\n5. Performance Monitoring (if applicable).\nThe contractor will be monitored by the COR and Energy Plant operator staff on a daily basis and the contractor will submit a maintenance report showing the date and what work was completed.\n7. Security Requirements.\n\nThe contractor employees shall not have access to VA sensitive or computer information and will not require routine access to VA Facilities. The contractor employees shall require intermittent access only and will be escorted by VA employees while at VA Facilities. No background investigation is required\nThe COR and Energy Plant Operating staff will inspect the maintenance activities as they are performed and accept the work before equipment can be closed up and put back in service.\n8. Risk Control\nTo avoid interrupting patient care, this work will be scheduled per the period of performance such that it will only be performed when the cooling load is low enough that multiple chillers are not required.\n9. Place of Performance.\nThe work will be performed at the Energy Plant section of Building 100 at the Seattle Division of the VA Puget Sound Health Care System, 1660 S Columbian Way, Seattle, WA 98108.\n11. Period of Performance.\nThe maintenance work for Chillers and Cooling Tower 1 3 shall occur between the months of October to March. The maintenance work for Chiller and Cooling Tower 4 shall occur between the months of April to September.\n12. Delivery Schedule.\n\nThe contract shall submit a maintenance report detailing the work performed and any special notes on the condition of the equipment. The report shall detail the date that the maintenance was performed and the amount of time to conduct it.\n\nEND OF DRAFT STATEMENT OF WORK","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26025Q0621","place_of_performance":{"zip":"98108","city":{"name":"Seattle"},"state":{"name":"Washington"},"street":"Department of Veterans Affairs Seattle VA Medical Center","street2":"1660 South Columbian Way"},"product_service_code":"J041"}],"due_at":"2025-07-10T22:00:00Z","due_date":"2025-07-10","closes_at":"2025-07-10T22:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","state":"WA","county":"53033","county_name":"King County","city":"5363000","city_name":"Seattle","country":null,"state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-09T03:24:22.313841Z","principal_notice_id":"c07d4f6b7584439f88d262a5cf97e186","description":{"text":"DESCRIPTION\nTHIS IS A REQUEST FOR INFORMATION ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this sources sought to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services:\n\nProposed NAICS Code 811310. Any questions or concerns may be directed to Derek Crockett via e-mail at derek.crockett@va.gov.\n\nRESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS:\n1.) Company name, address, and business size; point of contact name, phone number, and e-mail address.\n2.) Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program and the anticipated North American Industry Classification System (NAICS) code.\n\n[ ] yes [ ] no Small Business (SB)\n[ ] yes [ ] no HUBZone\n[ ] yes [ ] no Small Business 8(a)\n[ ] yes [ ] no Small Disadvantaged Business (SDB)\n[ ] yes [ ] no Women-Owned (WO) Small Business\n[ ] yes [ ] no Service Disabled Veteran Owned Small Business (SDVOSB)\n[ ] yes [ ] no Veteran Owned Small Business (VOSB)\n[ ] yes [ ] no Other (please specify)\n\n3.) Can you provide firm-fixed-pricing for the scope of services and supplies outlined in the Draft SOW below and for a period of five years?\n\n4.) Does your firm have staff with industry relevant industry certificates and Washington State credentials and/or licenses such as those detailed below? If yes, please list what certifications and licenses your firm and staff currently holds.\n\n5.) Does your firm have any existing contracts with the federal government or specific government agencies? (GSA, FSS, ect). If yes, please list the contract number(s) and agency contracts.\n\n6.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement?\n\n7.) Please provide a capability statement (not to exceed 5 pages) detailing any current or historical projects for similar requirements.\n\nDRAFT STATEMENT OF WORK (SOW):\nSTATEMENT OF WORK (SOW)\nas of 12/Feb/2025\n\n1. Contract Title. Annual Chiller Maintenance for SEA Energy Plant\n2. Background.\nThe Seattle VA has a large complicated chilled water system consisting of 4 water cooled 825 ton centrifugal chillers and 4 matching two cell counter-flow condenser water cooling towers. This system is used to create chilled water that is pumped throughout the campus to air handler cooling coils that cool and dehumidify air that is circulated throughout our buildings to cool people and equipment. The maintenance requirements for this equipment is specific and time consuming. At this time the existing Seattle VA Energy Plant operating staff do not have the manpower to conduct this extensive maintenance activity.\n3. Scope.\n\nThe scope is for a contractor to provide annual maintenance on our chillers, cooling towers, and condenser water pumps per the specific tasks and schedule listed below. Contractor located no further than 50 miles of Seattle VAMC and must be able to respond to an emergency call within one hour.\n\n4. Specific Tasks.\n\nEquipment Information:\nFour 825 Ton JCI/York model YKKCKQH9-EUG water cooled centrifugal chillers\nFour 2 cell Marley model MD5010QAF2L counter flow cooling towers\nSix 30 horsepower Baldor motors powering Grundfos condenser water pumps\nThree 150 horsepower Baldor motors powering Grundfos chilled water pumps\n\nThe Annual Equipment Inspection and PM:\n\nChecking the Compressor-Motor Assembly for the following items and performing PM Tasks as indicated:\nRecording voltages\nMegging and recording motor winding resistance\nLubricating open motor\nChecking the alignment on open drive units\nChecking the coupling\nChecking seals\nChecking inlet vane operator and linkage; lubricating where required\n\nChecking the Compressor Oil System for the following items:\nChanging oil filter, and dryer\nConducting analysis on oil at an independent laboratory\nChecking oil pump, seal and motor\nChecking heater and thermostat\nChecking all other oil system components including cooler, strainer and solenoid valve where applicable\n\nReview the Control Panel for the following items:\nRunning diagnostic check of Optiview Control Panel\nChecking safety shutdown operation\nChecking all terminals and tightening connections\nChecking Display Data accuracy and set points\n\nChecking the Condenser for the following items:\nChecking the water flow\nChecking flow switch operation\nRemoving condenser head and inspecting end sheets\n\nChecking the Cooler for the following items:\nChecking the water flow\nChecking flow switch operation\nChecking refrigerant level\n\nChecking the System for the following items:\nConducting a leak check and identifying leak sources for repairs\nAdding refrigerant as required (refrigerant provided by owner)\nRecording condition of sight glasses\nChecking the refrigerant cycle to verify the proper operating balance\nChecking condenser water and chilled water heat transfer\n\nGeneral items included:\nRepairing insulation removed for inspection and maintenance procedures\nCleaning equipment and surrounding area upon completion of work\nConsulting with the operator\nReporting deficiencies and repairs required\n\nYORK VSD\nRecord all power and control voltages for proper operation of drive\nVerify proper operation of cooling circuit and backflush heat exchanger (VSD only)\nChange closed loop coolant fluid every year\nCheck condenser water loop strainer (VSD only)\nCheck vane pot calibration and recalibrate when required\n\nScope of Maintenance Cooling Tower Service Performed:\nClean pan (basin) strainer\nClean and flush pan (basin)\nCheck bleed off to make sure it is operative\nCheck and adjust water level in cold water basin\nClean water distribution system and spray nozzles\nCheck drift eliminators for plugging\nEnsure that all fan hardware is tight and inspect fan for cracks\nLubricate fan-shaft bearings and drive train\nInstall new fan belts (if applicable)\nLubricate motor-base-adjusting screw\nEnsure proper operation of all drive components\nCheck and record amp draw on fan motor\nClean air-inlet louvers as good as possible without causing damage\nPressure wash interior of tower to remove any algae\nInspect for rust and leaks and repair minor leaks\nInspect vibration switch and adjust sensitivity if needed\nInspect sweeper piping for cracks and plugging\n\nPumps (9) total\nPump strainer cleaning and pump maintenance and vibration analysis Isolation valve must be present and functioning Assuming 1 evaporator and 1 condenser per chiller\nInspect pump seals and replace/repair where needed.\n5. Performance Monitoring (if applicable).\nThe contractor will be monitored by the COR and Energy Plant operator staff on a daily basis and the contractor will submit a maintenance report showing the date and what work was completed.\n7. Security Requirements.\n\nThe contractor employees shall not have access to VA sensitive or computer information and will not require routine access to VA Facilities. The contractor employees shall require intermittent access only and will be escorted by VA employees while at VA Facilities. No background investigation is required\nThe COR and Energy Plant Operating staff will inspect the maintenance activities as they are performed and accept the work before equipment can be closed up and put back in service.\n8. Risk Control\nTo avoid interrupting patient care, this work will be scheduled per the period of performance such that it will only be performed when the cooling load is low enough that multiple chillers are not required.\n9. Place of Performance.\nThe work will be performed at the Energy Plant section of Building 100 at the Seattle Division of the VA Puget Sound Health Care System, 1660 S Columbian Way, Seattle, WA 98108.\n11. Period of Performance.\nThe maintenance work for Chillers and Cooling Tower 1 3 shall occur between the months of October to March. The maintenance work for Chiller and Cooling Tower 4 shall occur between the months of April to September.\n12. Delivery Schedule.\n\nThe contract shall submit a maintenance report detailing the work performed and any special notes on the condition of the equipment. The report shall detail the date that the maintenance was performed and the amount of time to conduct it.\n\nEND OF DRAFT STATEMENT OF WORK","html":"DESCRIPTION\nTHIS IS A REQUEST FOR INFORMATION ONLY.  This is not a solicitation for bids, proposals, proposal abstracts, or quotations.  The purpose of this sources sought to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement.  The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services:\n\nProposed NAICS Code 811310. Any questions or concerns may be directed to Derek Crockett via e-mail at derek.crockett@va.gov.\n\nRESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS:  \n1.) Company name, address, and business size; point of contact name, phone number, and e-mail address.\n2.)  Is your firm eligible for participation in one of the following small business programs?  If so, please indicate the program and the anticipated North American Industry Classification System (NAICS) code. \n\n[  ] yes   [  ] no     Small Business (SB) \n[  ] yes   [  ] no     HUBZone \n[  ] yes   [  ] no     Small Business 8(a) \n[  ] yes   [  ] no     Small Disadvantaged Business (SDB) \n[  ] yes   [  ] no     Women-Owned (WO) Small Business\n[  ] yes   [  ] no     Service Disabled Veteran Owned Small Business (SDVOSB)\n[  ] yes   [  ] no     Veteran Owned Small Business (VOSB) \n[  ] yes   [  ] no     Other (please specify) \n\n3.) Can you provide firm-fixed-pricing for the scope of services and supplies outlined in the Draft SOW below and for a period of five years?\n\n4.) Does your firm have staff with industry relevant industry certificates and Washington State credentials and/or licenses such as those detailed below? If yes, please list what certifications and licenses your firm and staff currently holds. \n\n5.) Does your firm have any existing contracts with the federal government or specific government agencies? (GSA, FSS, ect). If yes, please list the contract number(s) and agency contracts. \n\n6.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement?\n\n7.) Please provide a capability statement (not to exceed 5 pages) detailing any current or historical projects for similar requirements.\n\nDRAFT STATEMENT OF WORK (SOW):\nSTATEMENT OF WORK (SOW)\nas of 12/Feb/2025\n\n\n1.  Contract Title.  Annual Chiller Maintenance for SEA Energy Plant\n2.  Background.  \nThe Seattle VA has a large complicated chilled water system consisting of 4 water cooled 825 ton centrifugal chillers and 4 matching two cell counter-flow condenser water cooling towers. This system is used to create chilled water that is pumped throughout the campus to air handler cooling coils that cool and dehumidify air that is circulated throughout our buildings to cool people and equipment. The maintenance requirements for this equipment is specific and time consuming. At this time the existing Seattle VA Energy Plant operating staff do not have the manpower to conduct this extensive maintenance activity.\n3.  Scope. \n\nThe scope is for a contractor to provide annual maintenance on our chillers, cooling towers, and condenser water pumps per the specific tasks and schedule listed below. Contractor located no further than 50 miles of Seattle VAMC and must be able to respond to an emergency call within one hour.\n\n4. Specific Tasks.  \n\nEquipment Information:\nFour 825 Ton JCI/York model YKKCKQH9-EUG water cooled centrifugal chillers\nFour 2 cell Marley model MD5010QAF2L counter flow cooling towers\nSix 30 horsepower Baldor motors powering Grundfos condenser water pumps\nThree 150 horsepower Baldor motors powering Grundfos chilled water pumps\n\nThe Annual Equipment Inspection and PM:\n\nChecking the Compressor-Motor Assembly for the following items and performing PM Tasks as indicated:\n Recording voltages\n Megging and recording motor winding resistance\n Lubricating open motor\n Checking the alignment on open drive units\n Checking the coupling\n Checking seals\n Checking inlet vane operator and linkage; lubricating where required\n  \nChecking the Compressor Oil System for the following items:\n Changing oil filter, and dryer\n Conducting analysis on oil at an independent laboratory\n Checking oil pump, seal and motor\n Checking heater and thermostat\n Checking all other oil system components including cooler, strainer and solenoid valve   where  applicable\n  \nReview the Control Panel for the following items:\n Running diagnostic check of Optiview Control Panel\n Checking safety shutdown operation\n Checking all terminals and tightening connections\n Checking Display Data accuracy and set points\n  \nChecking the Condenser for the following items:\n Checking the water flow\n Checking flow switch operation\n Removing condenser head and inspecting end sheets\n \nChecking the Cooler for the following items:\n Checking the water flow\n Checking flow switch operation\n Checking refrigerant level\n \nChecking the System for the following items:\n Conducting a leak check and identifying leak sources for repairs\n Adding refrigerant as required (refrigerant provided by owner)\n Recording condition of sight glasses\n Checking the refrigerant cycle to verify the proper operating balance\n Checking condenser water and chilled water heat transfer\n  \nGeneral items included:\n Repairing insulation removed for inspection and maintenance procedures\n Cleaning equipment and surrounding area upon completion of work\n Consulting with the operator\n Reporting deficiencies and repairs required\n \nYORK VSD\n Record all power and control voltages for proper operation of drive\n Verify proper operation of cooling circuit and backflush heat exchanger (VSD only)\n Change closed loop coolant fluid every year\n Check condenser water loop strainer (VSD only)\n Check vane pot calibration and recalibrate when required\n  \nScope of Maintenance Cooling Tower Service Performed:\n  Clean pan (basin) strainer\n Clean and flush pan (basin)\n Check bleed off to make sure it is operative\n Check and adjust water level in cold water basin\n Clean water distribution system and spray nozzles\n Check drift eliminators for plugging\n Ensure that all fan hardware is tight and inspect fan for cracks\n Lubricate fan-shaft bearings and drive train\n Install new fan belts (if applicable) \n Lubricate motor-base-adjusting screw\n Ensure proper operation of all drive components\n Check and record amp draw on fan motor\n Clean air-inlet louvers as good as possible without causing damage\n Pressure wash interior of tower to remove any algae\n Inspect for rust and leaks and repair minor leaks\n Inspect vibration switch and adjust sensitivity if needed\n Inspect sweeper piping for cracks and plugging \n \nPumps (9) total\nPump strainer cleaning and pump maintenance and vibration analysis Isolation valve must be present and functioning Assuming 1 evaporator and 1 condenser per chiller \nInspect pump seals and replace/repair where needed. \n5. Performance Monitoring (if applicable).\nThe contractor will be monitored by the COR and Energy Plant operator staff on a daily basis and the contractor will submit a maintenance report showing the date and what work was completed.\n7. Security Requirements.\n\nThe contractor employees shall not have access to VA sensitive or computer information and will not require routine access to VA Facilities.  The contractor employees shall require intermittent access only and will be escorted by VA employees while at VA Facilities. No background investigation is required\nThe COR and Energy Plant Operating staff will inspect the maintenance activities as they are performed and accept the work before equipment can be closed up and put back in service.\n8. Risk Control\nTo avoid interrupting patient care, this work will be scheduled per the period of performance such that it will only be performed when the cooling load is low enough that multiple chillers are not required.\n9.  Place of Performance. \nThe work will be performed at the Energy Plant section of Building 100 at the Seattle Division of the VA Puget Sound Health Care System, 1660 S Columbian Way, Seattle, WA 98108.\n 11.  Period of Performance. \nThe maintenance work for Chillers and Cooling Tower 1   3 shall occur between the months of October to March. The maintenance work for Chiller and Cooling Tower 4 shall occur between the months of April to September. \n12.  Delivery Schedule. \n\nThe contract shall submit a maintenance report detailing the work performed and any special notes on the condition of the equipment. The report shall detail the date that the maintenance was performed and the amount of time to conduct it.\n\nEND OF DRAFT STATEMENT OF WORK","origin":"detail"},"contacts":[{"name":"Derek Crockett","role":"primary","email":"Derek.Crockett@va.gov","phone":"360-816-2760 x32760","title":"Contract Specialist"}],"place_of_performance":{"zip":"98108","city":{"name":"Seattle"},"state":{"name":"Washington"},"street":"Department of Veterans Affairs Seattle VA Medical Center","street2":"1660 South Columbian Way"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"05e06fd5d9eb4e118af1e7b0911b74c0","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-07-18T23:20:58.490Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false}],"awards":[],"related":[{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26027Q0117","latest_notice_id":"b6d17aea5ceb4b8d988004142043a40b","title":"6550 Reagents Consumables Microbiology Testing Boise VAMC","solicitation_number":"36C26027Q0117","notice_type":"r","first_type":"r","first_posted":"2026-11-09","last_posted":"2026-11-09","notices":1,"due_at":"2026-11-28T01:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"325413","psc":"6550","set_aside":null,"state":"ID","county":"16001","county_name":"Ada County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Boise VA Medical Center","site_key":"boise-va-medical-center-id","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"36C26026Q0981","latest_notice_id":"f9240f8b1e9a4da7aa654200bac827aa","title":"WSNC Medical Coding Books","solicitation_number":"36C26026Q0981","notice_type":"o","first_type":"o","first_posted":"2026-10-08","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-01T18:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"513130","psc":"7610","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26027R00020007","latest_notice_id":"9c90cd15f29d407c9ea106c281373e63","title":"Y1DA--CON NRM 531-25-102 | Expand Emergency Room","solicitation_number":"36C26027R0002-0007","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C26027R0021","latest_notice_id":"7a19b19c49c240a496641c5f39341d63","title":"Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center","solicitation_number":"36C26027R0021","notice_type":"o","first_type":"p","first_posted":"2026-10-16","last_posted":"2026-11-24","notices":5,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"238220","psc":"Z1DA","set_aside":"SDVOSBC","state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Mann-Grandstaff VA Medical Center","site_key":"mann-grandstaff-va-medical-center-wa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"W912EF27QA006","latest_notice_id":"7c3b9228948945cbab4a7f0b98539397","title":"LLA Fish Pump - Motor Rewind","solicitation_number":"W912EF27QA006","notice_type":"k","first_type":"k","first_posted":"2026-10-22","last_posted":"2026-11-20","notices":2,"due_at":"2026-11-30T19:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912EF","office_name":"US ARMY ENGINEER DISTRICT WALLA WAL","naics":"811310","psc":"J043","set_aside":null,"state":"WA","county":"53023","county_name":"Garfield County","city":"5355120","city_name":"Pomeroy","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"FA462027QA205","latest_notice_id":"54f6ff4a5460436aa5e46579e3bd3d5d","title":"PAINT/SANDING BOOTH, AIR SHOWER, & CABINET BLASTER MAINTENANCE","solicitation_number":"FA462027QA205","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-15T18:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4620","office_name":"FA4620 92 CONS LGC","naics":"811310","psc":"J049","set_aside":"SBA","state":"WA","county":"53063","county_name":"Spokane County","city":"5322955","city_name":"Fairchild AFB","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W50S6Y27RA002","latest_notice_id":"87cba3e75e354d12990453adb59fe26e","title":"Halon Bottle Inspection","solicitation_number":"W50S6Y27RA002","notice_type":"o","first_type":"r","first_posted":"2026-11-07","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S6Y","office_name":"W7M2 USPFO ACTIVITY FLANG 125","naics":"811310","psc":"J042","set_aside":"SBA","state":"FL","county":"12031","county_name":"Duval County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":56,"indexable":false}