{"canonical":"https://sealedbidder.com/opportunities/36c26025q0328","key":"36C26025Q0328","url":"https://sealedbidder.com/opportunities/36c26025q0328","title":"J045--668-25-2-5058-0051 CON NRM - Boiler Communication Controls","solicitation_number":"36C26025Q0328","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-14T17:00:00Z","first_posted":"2025-03-12","last_posted":"2025-03-12","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"811210","psc":"J045","set_aside":"SDVOSBC","place_state":"WA","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"53063","place_county_name":"Spokane County","place_city":"5367000","place_city_name":"Spokane","winner":null,"award_amount":null,"publications":[{"notice_id":"2c8425cc89c24f9db0934f93aa24b91c","title":"J045--668-25-2-5058-0051 CON NRM - Boiler Communication Controls","solicitation_number":"36C26025Q0328","notice_type":"r","base_type":"r","posted":"2025-03-12","posted_at":"2025-03-12T17:13:49.779Z","due_at":"2025-03-14T17:00:00Z","due_date":"2025-03-14","cancelled":false,"archived":true,"archive_date":"2025-03-24","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2c8425cc89c24f9db0934f93aa24b91c/view","enriched":true,"history":[{"index":3,"title":"J045--668-25-2-5058-0051 CON NRM - Boiler Communication Controls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-12T17:13:49.779Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2c8425cc89c24f9db0934f93aa24b91c","solicitation_number":"36C26025Q0328"}]}],"latest_notice_id":"2c8425cc89c24f9db0934f93aa24b91c","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-03-12","posted_at":"2025-03-12T17:13:49.779Z","created_at":"2025-03-12T17:13:19.873Z","modified_at":"2025-03-25T03:55:46.332Z","response_deadline":{"raw":"2025-03-14T10:00:00-07:00","utc":"2025-03-14T17:00:00Z","date":"2025-03-14","time":"10:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2c8425cc89c24f9db0934f93aa24b91c/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J045--668-25-2-5058-0051 CON NRM - Boiler Communication Controls","agency":{"office":{"code":"36C260","name":"260-NETWORK CONTRACT OFFICE 20 (36C260)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"organization_id":"100186526","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-24","archive_type":"auto_custom"},"history":[{"index":3,"title":"J045--668-25-2-5058-0051 CON NRM - Boiler Communication Controls","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-12T17:13:49.779Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2c8425cc89c24f9db0934f93aa24b91c","solicitation_number":"36C26025Q0328"}],"contacts":[{"name":"Kyle Biessener","role":"primary","email":"kyle.biessener@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"2c8425cc89c24f9db0934f93aa24b91c","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"2c8425cc89c24f9db0934f93aa24b91c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T12:14:30.549170331Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"96ba3f7b544bcf3812696678813b6b194c376a8a487ceb67e885ebf0b53b2e76","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-20T12:14:30.549170331Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"THIS IS A SOURCES SOUGHT NOTICE ONLY.  This is not a solicitation for bids, proposals, proposal abstracts, or quotations.  The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services:\n\nProposed NAICS Code 811210 is applicable to determine business size standard. Any questions or concerns may be directed to Kyle Biessener via e-mail at kyle.biessener@va.gov.\n\nRESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS:  \n1.) company name, address, and business size; point of contact name, phone number, and e-mail address.\n2.)  Capability statement of your firm and any current or historical projects for similar requirements. \n3.) How long do you estimate it would take complete the services required? \n4.) Can you provide firm-fixed-pricing for the scope of services and supplies required below?\n5.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement?\n\nDRAFT STATEMENT OF WORK (SOW):\nScope\nReplace, test, and calibrate communication controls and instruments for 4 separate boilers in accordance with ISO 17025 standards and VA Directive 1810. Service will be to replace the current can bus system with a 4-20MA control system. Contractor shall be located within a 120-mile radius of the Spokane VA Medical Center, and shall furnish all materials, tools, and devices needed to complete the work detailed in this document.\nPlace of Performance \n Work to be performed at the Mann-Grandstaff VA Medical Center, located at 4815 North Assembly Street, Spokane, WA 99205\n\n\n\n\nTechnician Qualifications \nAt a minimum, qualified technicians shall:\nBe employed with an ISO 17025 certified business and have five years of successful experience in the field. The experience should be largely with institutional and industrial boiler plants similar in design to the VAMC plant as specified below.\nBe certified as competent to perform calibrations in accordance with ISO 17025 standards.\nDemonstrate familiarity and show proof of compliance with VA directive 1810, and have ready access to the current versions of the following references: \n             \n   - NFPA 85, Boiler and Combustion Systems Hazards Code. \n             - VHA Boiler Plant Safety Device Testing Manual, 8th Edition.\n              - VHA Directive 2008-062\n\nDemonstrate working knowledge of Spokane Air requirements for emission parameters and the ability to perform to these standards.  \nBe equipped with portable electronic flue gas analyzers and other test instruments necessary for the required tests and calibrations. Instruments must be calibrated within six months of the site visits. \nBe capable of programming digital controls, and possess the appropriate hardware and software needed to accomplish the task.\nProvide proof of at least 3 years work experience performing the VA s Safety Devices Testing Program.\nFor issues that may arise during the installation period, provide at least a 48-hour response time to address routine issues, and a 2-hour response time to address critical issues.\nSpecific Tasks  \nProvide for each boiler (4 in total):\nSet of as-built drawings. \nNew control panels. \nNew process controller. \nNew Honeywell BMS or equivalent, including first out annunciator. All Fireye brands are being replaced. \nNew actuators for gas, oil, FD air and FGR control. 4 Per boiler.\nProvide installation of the above-mentioned equipment, to include startup, gas, and oil. \nPerform 1 Gas and 1 oil combustion tuning.\nPerform steam pressure and drum level process tuning.\nPerform tuning, testing, calibrating, and adjustments of burners in accordance with OCM Instrumentation Testing Criteria.\nConduct calibration and certification of control instrumentation in accordance with VA requirements, complete with required paperwork and display stickers.\nContractor shall provide at least one week notice to the Person of Contact (POC) prior to performing the work. Work cannot be scheduled during heavy steam load periods. Only one boiler at a time can be out of service for the inspection, testing and calibration procedures. Work must be conducted when the POC or his/her designee is available on site to monitor the work. \nBoiler Specifications\nThe aforementioned tasks shall be performed on the specified boilers:\nBoilers 1 & 2\n\nSubtitle: 2X 350 HP Boiler \nManufacturer: Burnham \nBoiler Type: Fire tube Boiler \nYear Built: 2020  \nDesign Pressure: 200.00 PSI \nOperating Pressure: 120.00 PSI [relief valve set pressure] \nDesign Temperature: 650.00 degrees Fahrenheit\nRated Capacity: 12,000 pounds per hour\nFuel: Natural gas and or #2 fuel oil fired boilers.\n2 x profiles to be tuned per boiler.\n\nBoilers 3 & 4\n\nSubtitle: 2X 200 HP Boiler \nManufacturer: Burnham \nBoiler Type: Fire tube Boiler \nYear Built: 2020  \nDesign Pressure: 200.00 PSI \nOperating Pressure: 120.00 PSI [relief valve set pressure] \nDesign Temperature: 650.00 degrees Fahrenheit\nRated Capacity: 6900 pounds per hour\nFuel: Natural gas and or #2 fuel oil fired boilers.\n2 x profiles to be tuned per boiler.\n\nOther Pertinent Information or Special Considerations. \n\na.  Identification of Possible Follow-on Work.  \n\n Installing new boiler communication controls could potentially require follow on services.\n\nb.  Identification of Potential Conflicts of Interest (COI). \n\n     N/A\n\nc.  Identification of Non-Disclosure Requirements. \n\n  Sensitive or proprietary information issues are not applicable to this job.\n\nd.  Packaging, Packing and Shipping Instructions.  \n\n N/A.\n\ne.  Inspection and Acceptance Criteria.  \n\n The Contract Officer Representative (COR) is responsible for certifying that the work done under the contract is performed to time and standard. They are also responsible to assure the inspection and acceptance of products provided incidental to services.\n\n\nPotential candidates having the capabilities necessary to provide the above stated services are invited to respond to this Sources Sought Notice via e-mail to Kyle Biessener at kyle.biessener@va.gov no later than 03/20/2025 by 4:30 PM Pacific Standard Time. No telephone inquiries will be accepted. \n\nDisclaimer and Important Notes:  This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies.  Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement.  There is no solicitation available at this time.","text":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services:\n\nProposed NAICS Code 811210 is applicable to determine business size standard. Any questions or concerns may be directed to Kyle Biessener via e-mail at kyle.biessener@va.gov.\n\nRESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS:\n1.) company name, address, and business size; point of contact name, phone number, and e-mail address.\n2.) Capability statement of your firm and any current or historical projects for similar requirements.\n3.) How long do you estimate it would take complete the services required?\n4.) Can you provide firm-fixed-pricing for the scope of services and supplies required below?\n5.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement?\n\nDRAFT STATEMENT OF WORK (SOW):\nScope\nReplace, test, and calibrate communication controls and instruments for 4 separate boilers in accordance with ISO 17025 standards and VA Directive 1810. Service will be to replace the current can bus system with a 4-20MA control system. Contractor shall be located within a 120-mile radius of the Spokane VA Medical Center, and shall furnish all materials, tools, and devices needed to complete the work detailed in this document.\nPlace of Performance\nWork to be performed at the Mann-Grandstaff VA Medical Center, located at 4815 North Assembly Street, Spokane, WA 99205\n\nTechnician Qualifications\nAt a minimum, qualified technicians shall:\nBe employed with an ISO 17025 certified business and have five years of successful experience in the field. The experience should be largely with institutional and industrial boiler plants similar in design to the VAMC plant as specified below.\nBe certified as competent to perform calibrations in accordance with ISO 17025 standards.\nDemonstrate familiarity and show proof of compliance with VA directive 1810, and have ready access to the current versions of the following references:\n\n- NFPA 85, Boiler and Combustion Systems Hazards Code.\n- VHA Boiler Plant Safety Device Testing Manual, 8th Edition.\n- VHA Directive 2008-062\n\nDemonstrate working knowledge of Spokane Air requirements for emission parameters and the ability to perform to these standards.\nBe equipped with portable electronic flue gas analyzers and other test instruments necessary for the required tests and calibrations. Instruments must be calibrated within six months of the site visits.\nBe capable of programming digital controls, and possess the appropriate hardware and software needed to accomplish the task.\nProvide proof of at least 3 years work experience performing the VA s Safety Devices Testing Program.\nFor issues that may arise during the installation period, provide at least a 48-hour response time to address routine issues, and a 2-hour response time to address critical issues.\nSpecific Tasks\nProvide for each boiler (4 in total):\nSet of as-built drawings.\nNew control panels.\nNew process controller.\nNew Honeywell BMS or equivalent, including first out annunciator. All Fireye brands are being replaced.\nNew actuators for gas, oil, FD air and FGR control. 4 Per boiler.\nProvide installation of the above-mentioned equipment, to include startup, gas, and oil.\nPerform 1 Gas and 1 oil combustion tuning.\nPerform steam pressure and drum level process tuning.\nPerform tuning, testing, calibrating, and adjustments of burners in accordance with OCM Instrumentation Testing Criteria.\nConduct calibration and certification of control instrumentation in accordance with VA requirements, complete with required paperwork and display stickers.\nContractor shall provide at least one week notice to the Person of Contact (POC) prior to performing the work. Work cannot be scheduled during heavy steam load periods. Only one boiler at a time can be out of service for the inspection, testing and calibration procedures. Work must be conducted when the POC or his/her designee is available on site to monitor the work.\nBoiler Specifications\nThe aforementioned tasks shall be performed on the specified boilers:\nBoilers 1 & 2\n\nSubtitle: 2X 350 HP Boiler\nManufacturer: Burnham\nBoiler Type: Fire tube Boiler\nYear Built: 2020\nDesign Pressure: 200.00 PSI\nOperating Pressure: 120.00 PSI [relief valve set pressure]\nDesign Temperature: 650.00 degrees Fahrenheit\nRated Capacity: 12,000 pounds per hour\nFuel: Natural gas and or #2 fuel oil fired boilers.\n2 x profiles to be tuned per boiler.\n\nBoilers 3 & 4\n\nSubtitle: 2X 200 HP Boiler\nManufacturer: Burnham\nBoiler Type: Fire tube Boiler\nYear Built: 2020\nDesign Pressure: 200.00 PSI\nOperating Pressure: 120.00 PSI [relief valve set pressure]\nDesign Temperature: 650.00 degrees Fahrenheit\nRated Capacity: 6900 pounds per hour\nFuel: Natural gas and or #2 fuel oil fired boilers.\n2 x profiles to be tuned per boiler.\n\nOther Pertinent Information or Special Considerations.\n\na. Identification of Possible Follow-on Work.\n\nInstalling new boiler communication controls could potentially require follow on services.\n\nb. Identification of Potential Conflicts of Interest (COI).\n\nN/A\n\nc. Identification of Non-Disclosure Requirements.\n\nSensitive or proprietary information issues are not applicable to this job.\n\nd. Packaging, Packing and Shipping Instructions.\n\nN/A.\n\ne. Inspection and Acceptance Criteria.\n\nThe Contract Officer Representative (COR) is responsible for certifying that the work done under the contract is performed to time and standard. They are also responsible to assure the inspection and acceptance of products provided incidental to services.\n\nPotential candidates having the capabilities necessary to provide the above stated services are invited to respond to this Sources Sought Notice via e-mail to Kyle Biessener at kyle.biessener@va.gov no later than 03/20/2025 by 4:30 PM Pacific Standard Time. No telephone inquiries will be accepted.\n\nDisclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C26025Q0328","place_of_performance":{"zip":"99205","city":{"name":"Spokane"},"state":{"name":"WA"},"street":"4815 North Assembly Street","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J045"}],"due_at":"2025-03-14T17:00:00Z","due_date":"2025-03-14","closes_at":"2025-03-14T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-20T13:04:53.842173Z","principal_notice_id":"2c8425cc89c24f9db0934f93aa24b91c","description":{"text":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services:\n\nProposed NAICS Code 811210 is applicable to determine business size standard. Any questions or concerns may be directed to Kyle Biessener via e-mail at kyle.biessener@va.gov.\n\nRESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS:\n1.) company name, address, and business size; point of contact name, phone number, and e-mail address.\n2.) Capability statement of your firm and any current or historical projects for similar requirements.\n3.) How long do you estimate it would take complete the services required?\n4.) Can you provide firm-fixed-pricing for the scope of services and supplies required below?\n5.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement?\n\nDRAFT STATEMENT OF WORK (SOW):\nScope\nReplace, test, and calibrate communication controls and instruments for 4 separate boilers in accordance with ISO 17025 standards and VA Directive 1810. Service will be to replace the current can bus system with a 4-20MA control system. Contractor shall be located within a 120-mile radius of the Spokane VA Medical Center, and shall furnish all materials, tools, and devices needed to complete the work detailed in this document.\nPlace of Performance\nWork to be performed at the Mann-Grandstaff VA Medical Center, located at 4815 North Assembly Street, Spokane, WA 99205\n\nTechnician Qualifications\nAt a minimum, qualified technicians shall:\nBe employed with an ISO 17025 certified business and have five years of successful experience in the field. The experience should be largely with institutional and industrial boiler plants similar in design to the VAMC plant as specified below.\nBe certified as competent to perform calibrations in accordance with ISO 17025 standards.\nDemonstrate familiarity and show proof of compliance with VA directive 1810, and have ready access to the current versions of the following references:\n\n- NFPA 85, Boiler and Combustion Systems Hazards Code.\n- VHA Boiler Plant Safety Device Testing Manual, 8th Edition.\n- VHA Directive 2008-062\n\nDemonstrate working knowledge of Spokane Air requirements for emission parameters and the ability to perform to these standards.\nBe equipped with portable electronic flue gas analyzers and other test instruments necessary for the required tests and calibrations. Instruments must be calibrated within six months of the site visits.\nBe capable of programming digital controls, and possess the appropriate hardware and software needed to accomplish the task.\nProvide proof of at least 3 years work experience performing the VA s Safety Devices Testing Program.\nFor issues that may arise during the installation period, provide at least a 48-hour response time to address routine issues, and a 2-hour response time to address critical issues.\nSpecific Tasks\nProvide for each boiler (4 in total):\nSet of as-built drawings.\nNew control panels.\nNew process controller.\nNew Honeywell BMS or equivalent, including first out annunciator. All Fireye brands are being replaced.\nNew actuators for gas, oil, FD air and FGR control. 4 Per boiler.\nProvide installation of the above-mentioned equipment, to include startup, gas, and oil.\nPerform 1 Gas and 1 oil combustion tuning.\nPerform steam pressure and drum level process tuning.\nPerform tuning, testing, calibrating, and adjustments of burners in accordance with OCM Instrumentation Testing Criteria.\nConduct calibration and certification of control instrumentation in accordance with VA requirements, complete with required paperwork and display stickers.\nContractor shall provide at least one week notice to the Person of Contact (POC) prior to performing the work. Work cannot be scheduled during heavy steam load periods. Only one boiler at a time can be out of service for the inspection, testing and calibration procedures. Work must be conducted when the POC or his/her designee is available on site to monitor the work.\nBoiler Specifications\nThe aforementioned tasks shall be performed on the specified boilers:\nBoilers 1 & 2\n\nSubtitle: 2X 350 HP Boiler\nManufacturer: Burnham\nBoiler Type: Fire tube Boiler\nYear Built: 2020\nDesign Pressure: 200.00 PSI\nOperating Pressure: 120.00 PSI [relief valve set pressure]\nDesign Temperature: 650.00 degrees Fahrenheit\nRated Capacity: 12,000 pounds per hour\nFuel: Natural gas and or #2 fuel oil fired boilers.\n2 x profiles to be tuned per boiler.\n\nBoilers 3 & 4\n\nSubtitle: 2X 200 HP Boiler\nManufacturer: Burnham\nBoiler Type: Fire tube Boiler\nYear Built: 2020\nDesign Pressure: 200.00 PSI\nOperating Pressure: 120.00 PSI [relief valve set pressure]\nDesign Temperature: 650.00 degrees Fahrenheit\nRated Capacity: 6900 pounds per hour\nFuel: Natural gas and or #2 fuel oil fired boilers.\n2 x profiles to be tuned per boiler.\n\nOther Pertinent Information or Special Considerations.\n\na. Identification of Possible Follow-on Work.\n\nInstalling new boiler communication controls could potentially require follow on services.\n\nb. Identification of Potential Conflicts of Interest (COI).\n\nN/A\n\nc. Identification of Non-Disclosure Requirements.\n\nSensitive or proprietary information issues are not applicable to this job.\n\nd. Packaging, Packing and Shipping Instructions.\n\nN/A.\n\ne. Inspection and Acceptance Criteria.\n\nThe Contract Officer Representative (COR) is responsible for certifying that the work done under the contract is performed to time and standard. They are also responsible to assure the inspection and acceptance of products provided incidental to services.\n\nPotential candidates having the capabilities necessary to provide the above stated services are invited to respond to this Sources Sought Notice via e-mail to Kyle Biessener at kyle.biessener@va.gov no later than 03/20/2025 by 4:30 PM Pacific Standard Time. No telephone inquiries will be accepted.\n\nDisclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time.","html":"THIS IS A SOURCES SOUGHT NOTICE ONLY.  This is not a solicitation for bids, proposals, proposal abstracts, or quotations.  The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services:\n\nProposed NAICS Code 811210 is applicable to determine business size standard. Any questions or concerns may be directed to Kyle Biessener via e-mail at kyle.biessener@va.gov.\n\nRESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION AND RESPONSES TO THE FOLLOWING QUESTIONS:  \n1.) company name, address, and business size; point of contact name, phone number, and e-mail address.\n2.)  Capability statement of your firm and any current or historical projects for similar requirements. \n3.) How long do you estimate it would take complete the services required? \n4.) Can you provide firm-fixed-pricing for the scope of services and supplies required below?\n5.) Based on the Draft Statement of Work (SOW) and scope of services stated below, what additional information would you need to accurately estimate the effort for this requirement?\n\nDRAFT STATEMENT OF WORK (SOW):\nScope\nReplace, test, and calibrate communication controls and instruments for 4 separate boilers in accordance with ISO 17025 standards and VA Directive 1810. Service will be to replace the current can bus system with a 4-20MA control system. Contractor shall be located within a 120-mile radius of the Spokane VA Medical Center, and shall furnish all materials, tools, and devices needed to complete the work detailed in this document.\nPlace of Performance \n Work to be performed at the Mann-Grandstaff VA Medical Center, located at 4815 North Assembly Street, Spokane, WA 99205\n\n\n\n\nTechnician Qualifications \nAt a minimum, qualified technicians shall:\nBe employed with an ISO 17025 certified business and have five years of successful experience in the field. The experience should be largely with institutional and industrial boiler plants similar in design to the VAMC plant as specified below.\nBe certified as competent to perform calibrations in accordance with ISO 17025 standards.\nDemonstrate familiarity and show proof of compliance with VA directive 1810, and have ready access to the current versions of the following references: \n             \n   - NFPA 85, Boiler and Combustion Systems Hazards Code. \n             - VHA Boiler Plant Safety Device Testing Manual, 8th Edition.\n              - VHA Directive 2008-062\n\nDemonstrate working knowledge of Spokane Air requirements for emission parameters and the ability to perform to these standards.  \nBe equipped with portable electronic flue gas analyzers and other test instruments necessary for the required tests and calibrations. Instruments must be calibrated within six months of the site visits. \nBe capable of programming digital controls, and possess the appropriate hardware and software needed to accomplish the task.\nProvide proof of at least 3 years work experience performing the VA s Safety Devices Testing Program.\nFor issues that may arise during the installation period, provide at least a 48-hour response time to address routine issues, and a 2-hour response time to address critical issues.\nSpecific Tasks  \nProvide for each boiler (4 in total):\nSet of as-built drawings. \nNew control panels. \nNew process controller. \nNew Honeywell BMS or equivalent, including first out annunciator. All Fireye brands are being replaced. \nNew actuators for gas, oil, FD air and FGR control. 4 Per boiler.\nProvide installation of the above-mentioned equipment, to include startup, gas, and oil. \nPerform 1 Gas and 1 oil combustion tuning.\nPerform steam pressure and drum level process tuning.\nPerform tuning, testing, calibrating, and adjustments of burners in accordance with OCM Instrumentation Testing Criteria.\nConduct calibration and certification of control instrumentation in accordance with VA requirements, complete with required paperwork and display stickers.\nContractor shall provide at least one week notice to the Person of Contact (POC) prior to performing the work. Work cannot be scheduled during heavy steam load periods. Only one boiler at a time can be out of service for the inspection, testing and calibration procedures. Work must be conducted when the POC or his/her designee is available on site to monitor the work. \nBoiler Specifications\nThe aforementioned tasks shall be performed on the specified boilers:\nBoilers 1 & 2\n\nSubtitle: 2X 350 HP Boiler \nManufacturer: Burnham \nBoiler Type: Fire tube Boiler \nYear Built: 2020  \nDesign Pressure: 200.00 PSI \nOperating Pressure: 120.00 PSI [relief valve set pressure] \nDesign Temperature: 650.00 degrees Fahrenheit\nRated Capacity: 12,000 pounds per hour\nFuel: Natural gas and or #2 fuel oil fired boilers.\n2 x profiles to be tuned per boiler.\n\nBoilers 3 & 4\n\nSubtitle: 2X 200 HP Boiler \nManufacturer: Burnham \nBoiler Type: Fire tube Boiler \nYear Built: 2020  \nDesign Pressure: 200.00 PSI \nOperating Pressure: 120.00 PSI [relief valve set pressure] \nDesign Temperature: 650.00 degrees Fahrenheit\nRated Capacity: 6900 pounds per hour\nFuel: Natural gas and or #2 fuel oil fired boilers.\n2 x profiles to be tuned per boiler.\n\nOther Pertinent Information or Special Considerations. \n\na.  Identification of Possible Follow-on Work.  \n\n Installing new boiler communication controls could potentially require follow on services.\n\nb.  Identification of Potential Conflicts of Interest (COI). \n\n     N/A\n\nc.  Identification of Non-Disclosure Requirements. \n\n  Sensitive or proprietary information issues are not applicable to this job.\n\nd.  Packaging, Packing and Shipping Instructions.  \n\n N/A.\n\ne.  Inspection and Acceptance Criteria.  \n\n The Contract Officer Representative (COR) is responsible for certifying that the work done under the contract is performed to time and standard. They are also responsible to assure the inspection and acceptance of products provided incidental to services.\n\n\nPotential candidates having the capabilities necessary to provide the above stated services are invited to respond to this Sources Sought Notice via e-mail to Kyle Biessener at kyle.biessener@va.gov no later than 03/20/2025 by 4:30 PM Pacific Standard Time. No telephone inquiries will be accepted. \n\nDisclaimer and Important Notes:  This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies.  Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement.  There is no solicitation available at this time.","origin":"detail"},"contacts":[{"name":"Kyle Biessener","role":"primary","email":"kyle.biessener@va.gov","title":"Contract Specialist"}],"place_of_performance":{"zip":"99205","city":{"name":"Spokane"},"state":{"name":"WA"},"street":"4815 North Assembly Street","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"98661","city":"VANCOUVER","state":"WA","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"711181a21ae04457a1c57b2699b27e7e","name":"36C26025Q0328.docx","kind":"file","mime_type":".docx","size_bytes":20091,"posted_at":"2025-03-12T17:13:49.779Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/711181a21ae04457a1c57b2699b27e7e/download","mirrored":false}],"awards":[],"related":[{"key":"36C26027R00020006","latest_notice_id":"299fab9bad854b0786fcc742e3f934d5","title":"Amendment 0006 to Provide Official RFI Responses, Update Solicitation Documents, Extend Proposal Due Date, & other Official Information","solicitation_number":"36C26027R0002-0006","notice_type":"o","first_type":"o","first_posted":"2026-11-10","last_posted":"2026-11-10","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-11T04:53:52.348876Z"},{"key":"36C26027Q0130","latest_notice_id":"865639d03bae440aaa4a2e2195e0abf9","title":"6515--SOURCES SOUGHT NOTICE FOR HEAD, SHOULDER, AND UPPER-EXTREMITY POSITIONING ACCESSORIES FOR THE MAQUET MEERA 7200 OPERATING TABLE","solicitation_number":"36C26027Q0130","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"339113","psc":"6515","set_aside":null,"state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C26027Q0117","latest_notice_id":"b6d17aea5ceb4b8d988004142043a40b","title":"6550 Reagents Consumables Microbiology Testing Boise VAMC","solicitation_number":"36C26027Q0117","notice_type":"r","first_type":"r","first_posted":"2026-11-09","last_posted":"2026-11-09","notices":1,"due_at":"2026-11-28T01:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"325413","psc":"6550","set_aside":null,"state":"ID","county":"16001","county_name":"Ada County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Boise VA Medical Center","site_key":"boise-va-medical-center-id","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-10T04:49:28.155858Z"},{"key":"36C26026Q0981","latest_notice_id":"f9240f8b1e9a4da7aa654200bac827aa","title":"WSNC Medical Coding Books","solicitation_number":"36C26026Q0981","notice_type":"o","first_type":"o","first_posted":"2026-10-08","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-01T18:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"513130","psc":"7610","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 7610)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C26027R00020007","latest_notice_id":"9c90cd15f29d407c9ea106c281373e63","title":"Y1DA--CON NRM 531-25-102 | Expand Emergency Room","solicitation_number":"36C26027R0002-0007","notice_type":"o","first_type":"o","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"ID","county":"16001","county_name":"Ada County","city":"1608830","city_name":"Boise City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"FA857127Q0012","latest_notice_id":"7e9eedb22d6841709dc019ba3f04e0aa","title":"PCDMIS CAD++ Software Renewal and CMM Calibration","solicitation_number":"FA857127Q0012","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"811210","psc":"J066","set_aside":null,"state":"GA","county":"13153","county_name":"Houston County","city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N6133127QJK06","latest_notice_id":"93a0f9980ac14f5d88d643e3e8c11363","title":"Sole Source to United Electronic Industries Inc for Long Term Channel CAMS Single Board Computer Control Alarm and Monitor Systems Unit Evaluation and Repair Services Per Attachments","solicitation_number":"N61331-27-Q-JK06","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N61331","office_name":"NAVAL SURFACE WARFARE CENTER","naics":"811210","psc":"J059","set_aside":null,"state":"FL","county":"12005","county_name":"Bay County","city":"1254725","city_name":"Panama City Beach","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"FA853826R0017","latest_notice_id":"3b037426d9cb41b9a93923a626fc3565","title":"Repair/Overhaul of Flat Panel Up Front Controller (FPUFC)","solicitation_number":"FA853826R0017","notice_type":"o","first_type":"p","first_posted":"2026-04-29","last_posted":"2026-09-29","notices":3,"due_at":"2026-11-25T17:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8538","office_name":"FA8538 AFSC PZAAB","naics":"811210","psc":"J059","set_aside":null,"state":"GA","county":null,"county_name":null,"city":"1380508","city_name":"Warner Robins","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-30T04:14:25.251125Z"}],"similar_open_total":64,"indexable":false}