Sources sought
Backflow Device Testing - Base Plus 4 for Seattle and Magnolia VAMC
36C26025Q0028
Department of Veterans Affairs, 260-Network Contract Office 20. Plumbing, Heating, and Air-Conditioning Contractors.
Response deadline
October 22, 2024 at 3:00 PM EDT
Closed 764 days ago. Posted October 15, 2024. Scheduled to archive November 6, 2024.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2024
58 like it are open now in plumbing, heating, and air-conditioning contractors
- Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center
Department of Veterans Affairs, 260-Network Contract Office 20
Due in 7 daysDec 2 - CON-NRM-668-22-106 Correct Domestic Water System
Department of Veterans Affairs, 260-Network Contract Office 20
SolicitationSDVOSBNAICS 238220Spokane, WA36C26027R0014Closes in 8 daysDec 3 - Tonasket Ranger Station HVAC Replacement Building 2007
Forest Service, USDA Forest Service
Combined synopsis and solicitationSmall businessNAICS 238220Tonasket, WA1240BJ27Q0006Closes in 9 daysDec 4
All 58 open in plumbing, heating, and air-conditioning contractors
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 238220 (plumbing, heating, and air-conditioning contractors), means no more than $19 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of October 15, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The contractor shall perform the following specific tasks for the Seattle and Magnolia VAMC: •Conduct comprehensive quarterly and annual inspections of all backflow preventionassemblies. •Certify each backflow prevention assembly in accordance with the latest publishedstandards. •Provide documentation and maintain certification records in compliance with theAmerican Backflow Preventer Association. •Maintain, clean, and service backflow prevention assemblies as needed. •Ensure all inspectors have received certification equivalent to the field test procedures inthe Manual of Cross-Connection Control, Tenth Edition. •Submit proof of required licenses and personnel qualifications to the Contracting Officerprior to contract award. •Inspect, test, repair, and provide preventive maintenance for up to 213 backflowprevention assemblies. •Perform all work in compliance with NFPA 13, 17, NFPA 25, ASME, ANSI, ASSE,ABPA, UPC, and other applicable Federal Regulations. •Provide inspection, testing, maintenance, and repair services by master plumbers,certified inspectors, testers, and mechanics qualified for backflow prevention assemblywork. •Submit all required documentation and maintain necessary licenses and personnelqualifications in compliance with Washington State regulations.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
October 15, 2024
Sources sought
Due October 22, 2024 at 3:00 PM EDT. SAM.gov, notice 7f616b37e41743c2890ac88871b85f63
Points of contact
- Adam Hilladam.hill3@va.gov3606195977