{"canonical":"https://sealedbidder.com/opportunities/36c25926r0082","key":"36C25926R0082","url":"https://sealedbidder.com/opportunities/36c25926r0082","title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","solicitation_number":"36C25926R0082","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-20T16:30:00Z","first_posted":"2026-07-06","last_posted":"2026-07-23","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"236220","psc":"Z2DA","set_aside":"SDVOSBC","place_state":"OK","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"40109","place_county_name":"Oklahoma County","place_city":"4055000","place_city_name":"Oklahoma City","winner":null,"award_amount":null,"publications":[{"notice_id":"c324f341cde94b7ea40c253023b6b4ba","title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","solicitation_number":"36C25926R0082","notice_type":"p","base_type":"p","posted":"2026-07-06","posted_at":"2026-07-06T21:00:26.063Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c324f341cde94b7ea40c253023b6b4ba/view","enriched":true,"history":[{"index":2,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:14:02.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b","solicitation_number":"36C25926R0082","parent_opportunity_id":"c324f341cde94b7ea40c253023b6b4ba"},{"index":1,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-06T21:00:26.063Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c324f341cde94b7ea40c253023b6b4ba","solicitation_number":"36C25926R0082"}]},{"notice_id":"7ca812dd89ba471aa0f2ad72f904143b","title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","solicitation_number":"36C25926R0082","notice_type":"p","base_type":"p","posted":"2026-07-09","posted_at":"2026-07-09T20:14:02.095Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7ca812dd89ba471aa0f2ad72f904143b/view","enriched":true,"history":[{"index":4,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:45:40.887Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","solicitation_number":"36C25926R0082","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":3,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:45:17.523Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"86fcf5bd787d4afebcb300ae64a81ceb","solicitation_number":"36C25926R0082","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":2,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:14:02.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b","solicitation_number":"36C25926R0082","parent_opportunity_id":"c324f341cde94b7ea40c253023b6b4ba"},{"index":1,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-06T21:00:26.063Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c324f341cde94b7ea40c253023b6b4ba","solicitation_number":"36C25926R0082"}]},{"notice_id":"86fcf5bd787d4afebcb300ae64a81ceb","title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","solicitation_number":"36C25926R0082","notice_type":"o","base_type":"p","posted":"2026-07-23","posted_at":"2026-07-23T21:45:17.523Z","due_at":"2026-08-20T16:30:00Z","due_date":"2026-08-20","cancelled":false,"archived":true,"archive_date":"2026-11-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/86fcf5bd787d4afebcb300ae64a81ceb/view","enriched":true,"history":[{"index":2,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:45:17.523Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"86fcf5bd787d4afebcb300ae64a81ceb","solicitation_number":"36C25926R0082","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":1,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:14:02.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b","solicitation_number":"36C25926R0082","parent_opportunity_id":"c324f341cde94b7ea40c253023b6b4ba"}]},{"notice_id":"9e657e02f23344be9cb2e0c95731db1b","title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","solicitation_number":"36C25926R0082","notice_type":"o","base_type":"p","posted":"2026-07-23","posted_at":"2026-07-23T21:45:40.887Z","due_at":"2026-08-20T16:30:00Z","due_date":"2026-08-20","cancelled":null,"archived":null,"archive_date":"2026-11-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9e657e02f23344be9cb2e0c95731db1b/view","enriched":true,"history":[{"index":8,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-16T19:23:48.690Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a3ea647d83c24bd4a774806d66ad4c7d","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":7,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T22:19:35.274Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"39fed56ba8e042d88455e8f5b266081a","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":6,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-20T14:18:38.537Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c45d073761be4dd98b335f269ad2fa54","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":5,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-17T17:07:32.595Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ea94c40ad665440b92ff7882dfef8fae","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":4,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-11T20:23:59.037Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"48f21172474c4577b35f98880e4c5a97","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":3,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:54:30.945Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f0a1bec4350c4c309a4d8fb3d1030050","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":2,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:45:40.887Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","solicitation_number":"36C25926R0082","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":1,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:14:02.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b","solicitation_number":"36C25926R0082","parent_opportunity_id":"c324f341cde94b7ea40c253023b6b4ba"}]}],"latest_notice_id":"9e657e02f23344be9cb2e0c95731db1b","first_type":"p","notices":[{"dates":{"posted":"2026-07-06","posted_at":"2026-07-06T21:00:26.063Z","created_at":"2026-07-06T21:00:23.791Z","modified_at":"2026-07-09T20:14:02.095Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/c324f341cde94b7ea40c253023b6b4ba/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2026-10-04","archive_type":"auto_custom"},"history":[{"index":2,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:14:02.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b","solicitation_number":"36C25926R0082","parent_opportunity_id":"c324f341cde94b7ea40c253023b6b4ba"},{"index":1,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-06T21:00:26.063Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c324f341cde94b7ea40c253023b6b4ba","solicitation_number":"36C25926R0082"}],"contacts":[{"name":"Christina Beeler-Blackburn","role":"primary","email":"christina.beeler-blackburn@va.gov","phone":"303-712-5744","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"c324f341cde94b7ea40c253023b6b4ba","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"c324f341cde94b7ea40c253023b6b4ba","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T03:40:19.430460587Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"61d48ea1a565394e13a52756fdaf0a96-26\"","fetched_at":"2026-10-03T03:51:06.422373044Z","row_sha256":"e2131d1c023ca88233592efb7bef4de60df600144654bc7a82022cf19f6a066b","last_modified":"2026-10-03T03:30:32Z"},"updated_at":"2026-10-03T03:51:06.422373044Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"THIS IS A PRESOLICIATION NOTICE   A REQUEST FOR PROPOSAL TO BE POSTED ON OR ABOUT JULY 20, 2024.\nRepair Parking Garage 1 Deficiencies (635-21-139)   Oklahoma City VAMC\n36C25926R0082\nThe Department of Veteran s Affairs has a requirement to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the OKC VA HCS at Oklahoma City, Oklahoma, 73104. \nThe chosen contractor is to provide all materials and labor to complete all soil testing. \nThe NAICS code for this procurement is 236220 with a small business size standard of $45.0 M.  This project will be 100% set-aside for Small Businesses, as stated below.\nThe POC for this project will be Christina Beeler-Blackburn. He can be contacted at 303-712-5744 or email at Christina.Beeler-Blackburn@va.gov.\n852.219-73Â  VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside.\nAs prescribed in 819.7011, insert the following clause:\nVAAR 852.219-73  VA NOTICE OF TOTAL SET-ASIDE FOR CERTIFIED SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESSES (JAN 2023) (DEVIATION)\n(a)Â Definition.Â for the Department of Veterans Affairs,  Service-disabled Veteran-owned small business concern or SDVOSB :\n(1) Means a small business concern -\n(i) Not less than 51 percent of which is owned by one or more service-disabled Veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled Veterans or eligible surviving spouses (see VAAR802.101, Surviving Spouse definition).\n(ii) The management and daily business operations of which are controlled by one or more service-disabled Veterans (or eligible surviving spouses) or, in the case of a service-disabled Veteran with permanent and severe disability, the spouse or permanent caregiver of such Veteran.\n(iii) The business meets Federal small business size standards for the applicable North American Industry Classification System (NAICS) code identified in the solicitation document.\n(iv) The business has been certified for ownership and control pursuant to 38 U.S.C. 8127, 13 CFR 128, and is listed as certified in the SBA certification database at https://veterans.certify.sba.gov/; and\n(v) The business agrees to comply with VAAR subpart 819.70 and Small Business Administration (SBA) regulations regarding small business size, government contracting, and the Veteran Small Business Certification Program at 13 CFR parts 121, 125, and 128.\n(2) The term  Service-disabled Veteran  means a Veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16).\n(3) The term  small business concern  has the meaning given that term under section 3 of the Small Business Act (15 U.S.C. 632).\n(4) The term   small business concern owned and controlled by Veterans with service-connected disabilities   has the meaning given the term   small business concern owned and controlled by service-disabled veterans   under section 3(q)(2) of the Small Business Act (15 U.S.C. 632(q)(2)).\n(5) The term  SDVOSB participant  or certified SDVOSB means a small business that has been certified in the SBA Veteran Small Business Certification Program and listed in the SBA certification database (see 13 CFR 128.102).\n(b) General. In order for a concern to submit an offer and be eligible for the award of an SDVOSB set-aside or sole source contract, the concern must qualify as a small business concern under the size standard corresponding to the NAICS code assigned to the contract and be listed as an SDVOSB participant in the SBA certification database as set forth in 13 CFR 128.\n(1) Offers received from entities that are not certified SDVOSBs and listed in the SBA certification database at the time of offer shall not be considered.\n(2) Any award resulting from this solicitation shall be made to a certified SDVOSB listed in the SBA certification database who is eligible at the time of submission of offer(s) and at the time of award.\n(3) The requirements in this clause apply to any contract, order, or subcontract where the firm receives a benefit or preference from its designation as an SDVOSB, including set-asides, sole source awards, and evaluation preferences.\n(c) Representation. Pursuant to 38 U.S.C. 8127(e), only certified SDVOSBs listed in the SBA certification database are considered eligible to receive award of a resulting contract. By submitting an offer, the prospective contractor represents that it is an eligible and certified SDVOSB as defined in this clause, 13 CFR 121, 125, and 128, and VAAR subpart 819.70.\n(d) Agreement/LOS certification. When awarded a contract action, including orders under multiple award contracts, an SDVOSB agrees that in the performance of the contract, the SDVOSB shall comply with requirements in VAAR subpart 819.70 and SBA regulations on small business size, and government contracting programs at 13 CFR part 121 and part 125, including the non-manufacturer rule and limitations on subcontracting (LOS) requirements in 13 CFR 121.406(b) and 13 CFR 125.6. For the purpose of limitations on subcontracting, only certified SDVOSBs listed in the SBA certification database (including independent contractors) shall be considered eligible and/or   similarly situated   (i.e., a firm that has the same small business program status as the prime contractor). An otherwise eligible firm further agrees to comply with the required LOS certification requirements in this solicitation (see 852.219 75 or 852.219 76 as applicable). These requirements are summarized as follows:\n(1) Services. In the case of a contract for services (except construction), the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance to firms that are not certified SDVOSBs listed in the SBA certification database (excluding direct costs to the extent they are not the principal purpose of the acquisition and the SDVOSB/ VOSB does not provide the service, such as airline travel, cloud computing services, or mass media purchases). When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract.\n(2)Â Supplies/products.\n(i) In the case of a contract for supplies or products (other than from a non-manufacturer of such supplies), the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, to firms that are not certified SDVOSBs listed in the SBA certification database. When a contract includes both supply and services, the 50 percent limitation shall apply only to the supply portion of the contract.\n(ii) In the case of a contract for supplies from a non-manufacturer, the SDVOSB prime contractor will supply the product of a domestic small business manufacturer or processor, unless a waiver as described in 13 CFR 121.406(b)(5) has been granted. Refer to 13 CFR 125.6(a)(2)(ii) for guidance pertaining to multiple item procurements.\n(3) General construction. In the case of a contract for general construction, the SDVOSB prime contractor will not pay more than 85% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, to firms that are not certified SDVOSBs listed in the SBA certification database.\n(4) Special trade construction contractors. In the case of a contract for special trade contractors, no more than 75% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, may be paid to firms that are not certified SDVOSBs listed in the SBA certification database.\n(5) Subcontracting. An SDVOSB subcontractor must meet the NAICS size standard assigned by the prime contractor and be certified and listed in the SBA certification database to count as similarly situated. Any work that a first tier SDVOSB subcontractor further subcontracts will count towards the percent of subcontract amount that cannot be exceeded. For supply or construction contracts, the cost of materials is excluded and not considered to be subcontracted. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the portion of the contract with the preponderance of the expenditure upon which the assigned NAICS is based. For information and more specific requirements, refer to 13 CFR 125.6.\n(e)Â Required limitations on subcontracting compliance measurement period.Â An SDVOSB shall comply with the limitations on subcontracting as follows:\n__By the end of the base term of the contract or order, and then by the end of each subsequent option period; or\nX_By the end of the performance period for each order issued under the contract.\n(f) Joint ventures. A joint venture may be considered eligible as an SDVOSB if the joint venture complies with the requirements in 13 CFR 128.402 and the managing joint venture partner makes the representations under paragraph (c) of this clause. A joint venture agrees that, in the performance of the contract, the applicable percentage specified in paragraph (d) of this clause will be performed by the aggregate of the joint venture participants.\n(g) Precedence. The VA Veterans First Contracting Program, as defined in VAAR 802.101, subpart 819.70, and this clause, takes precedence over any inconsistencies between the requirements of the SBA Veteran Small Business Certification Program and the VA Veterans First Contracting Program.\n(h) Misrepresentation. Pursuant to 38 U.S.C. 8127(g), any business concern, including all its principals, that is determined by VA to have willfully and intentionally misrepresented a company s SDVOSB status is subject to debarment from contracting with the Department for a period of not less than five years (see VAAR 809.406 2 Causes for Debarment).\n(End of clause)","text":"THIS IS A PRESOLICIATION NOTICE A REQUEST FOR PROPOSAL TO BE POSTED ON OR ABOUT JULY 20, 2024.\nRepair Parking Garage 1 Deficiencies (635-21-139) Oklahoma City VAMC\n36C25926R0082\nThe Department of Veteran s Affairs has a requirement to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the OKC VA HCS at Oklahoma City, Oklahoma, 73104.\nThe chosen contractor is to provide all materials and labor to complete all soil testing.\nThe NAICS code for this procurement is 236220 with a small business size standard of $45.0 M. This project will be 100% set-aside for Small Businesses, as stated below.\nThe POC for this project will be Christina Beeler-Blackburn. He can be contacted at 303-712-5744 or email at Christina.Beeler-Blackburn@va.gov.\n852.219-73Â VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside.\nAs prescribed in 819.7011, insert the following clause:\nVAAR 852.219-73 VA NOTICE OF TOTAL SET-ASIDE FOR CERTIFIED SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESSES (JAN 2023) (DEVIATION)\n(a)Â Definition.Â for the Department of Veterans Affairs, Service-disabled Veteran-owned small business concern or SDVOSB :\n(1) Means a small business concern -\n(i) Not less than 51 percent of which is owned by one or more service-disabled Veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled Veterans or eligible surviving spouses (see VAAR802.101, Surviving Spouse definition).\n(ii) The management and daily business operations of which are controlled by one or more service-disabled Veterans (or eligible surviving spouses) or, in the case of a service-disabled Veteran with permanent and severe disability, the spouse or permanent caregiver of such Veteran.\n(iii) The business meets Federal small business size standards for the applicable North American Industry Classification System (NAICS) code identified in the solicitation document.\n(iv) The business has been certified for ownership and control pursuant to 38 U.S.C. 8127, 13 CFR 128, and is listed as certified in the SBA certification database at https://veterans.certify.sba.gov/; and\n(v) The business agrees to comply with VAAR subpart 819.70 and Small Business Administration (SBA) regulations regarding small business size, government contracting, and the Veteran Small Business Certification Program at 13 CFR parts 121, 125, and 128.\n(2) The term Service-disabled Veteran means a Veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16).\n(3) The term small business concern has the meaning given that term under section 3 of the Small Business Act (15 U.S.C. 632).\n(4) The term small business concern owned and controlled by Veterans with service-connected disabilities has the meaning given the term small business concern owned and controlled by service-disabled veterans under section 3(q)(2) of the Small Business Act (15 U.S.C. 632(q)(2)).\n(5) The term SDVOSB participant or certified SDVOSB means a small business that has been certified in the SBA Veteran Small Business Certification Program and listed in the SBA certification database (see 13 CFR 128.102).\n(b) General. In order for a concern to submit an offer and be eligible for the award of an SDVOSB set-aside or sole source contract, the concern must qualify as a small business concern under the size standard corresponding to the NAICS code assigned to the contract and be listed as an SDVOSB participant in the SBA certification database as set forth in 13 CFR 128.\n(1) Offers received from entities that are not certified SDVOSBs and listed in the SBA certification database at the time of offer shall not be considered.\n(2) Any award resulting from this solicitation shall be made to a certified SDVOSB listed in the SBA certification database who is eligible at the time of submission of offer(s) and at the time of award.\n(3) The requirements in this clause apply to any contract, order, or subcontract where the firm receives a benefit or preference from its designation as an SDVOSB, including set-asides, sole source awards, and evaluation preferences.\n(c) Representation. Pursuant to 38 U.S.C. 8127(e), only certified SDVOSBs listed in the SBA certification database are considered eligible to receive award of a resulting contract. By submitting an offer, the prospective contractor represents that it is an eligible and certified SDVOSB as defined in this clause, 13 CFR 121, 125, and 128, and VAAR subpart 819.70.\n(d) Agreement/LOS certification. When awarded a contract action, including orders under multiple award contracts, an SDVOSB agrees that in the performance of the contract, the SDVOSB shall comply with requirements in VAAR subpart 819.70 and SBA regulations on small business size, and government contracting programs at 13 CFR part 121 and part 125, including the non-manufacturer rule and limitations on subcontracting (LOS) requirements in 13 CFR 121.406(b) and 13 CFR 125.6. For the purpose of limitations on subcontracting, only certified SDVOSBs listed in the SBA certification database (including independent contractors) shall be considered eligible and/or similarly situated (i.e., a firm that has the same small business program status as the prime contractor). An otherwise eligible firm further agrees to comply with the required LOS certification requirements in this solicitation (see 852.219 75 or 852.219 76 as applicable). These requirements are summarized as follows:\n(1) Services. In the case of a contract for services (except construction), the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance to firms that are not certified SDVOSBs listed in the SBA certification database (excluding direct costs to the extent they are not the principal purpose of the acquisition and the SDVOSB/ VOSB does not provide the service, such as airline travel, cloud computing services, or mass media purchases). When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract.\n(2)Â Supplies/products.\n(i) In the case of a contract for supplies or products (other than from a non-manufacturer of such supplies), the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, to firms that are not certified SDVOSBs listed in the SBA certification database. When a contract includes both supply and services, the 50 percent limitation shall apply only to the supply portion of the contract.\n(ii) In the case of a contract for supplies from a non-manufacturer, the SDVOSB prime contractor will supply the product of a domestic small business manufacturer or processor, unless a waiver as described in 13 CFR 121.406(b)(5) has been granted. Refer to 13 CFR 125.6(a)(2)(ii) for guidance pertaining to multiple item procurements.\n(3) General construction. In the case of a contract for general construction, the SDVOSB prime contractor will not pay more than 85% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, to firms that are not certified SDVOSBs listed in the SBA certification database.\n(4) Special trade construction contractors. In the case of a contract for special trade contractors, no more than 75% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, may be paid to firms that are not certified SDVOSBs listed in the SBA certification database.\n(5) Subcontracting. An SDVOSB subcontractor must meet the NAICS size standard assigned by the prime contractor and be certified and listed in the SBA certification database to count as similarly situated. Any work that a first tier SDVOSB subcontractor further subcontracts will count towards the percent of subcontract amount that cannot be exceeded. For supply or construction contracts, the cost of materials is excluded and not considered to be subcontracted. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the portion of the contract with the preponderance of the expenditure upon which the assigned NAICS is based. For information and more specific requirements, refer to 13 CFR 125.6.\n(e)Â Required limitations on subcontracting compliance measurement period.Â An SDVOSB shall comply with the limitations on subcontracting as follows:\n__By the end of the base term of the contract or order, and then by the end of each subsequent option period; or\nX_By the end of the performance period for each order issued under the contract.\n(f) Joint ventures. A joint venture may be considered eligible as an SDVOSB if the joint venture complies with the requirements in 13 CFR 128.402 and the managing joint venture partner makes the representations under paragraph (c) of this clause. A joint venture agrees that, in the performance of the contract, the applicable percentage specified in paragraph (d) of this clause will be performed by the aggregate of the joint venture participants.\n(g) Precedence. The VA Veterans First Contracting Program, as defined in VAAR 802.101, subpart 819.70, and this clause, takes precedence over any inconsistencies between the requirements of the SBA Veteran Small Business Certification Program and the VA Veterans First Contracting Program.\n(h) Misrepresentation. Pursuant to 38 U.S.C. 8127(g), any business concern, including all its principals, that is determined by VA to have willfully and intentionally misrepresented a company s SDVOSB status is subject to debarment from contracting with the Department for a period of not less than five years (see VAAR 809.406 2 Causes for Debarment).\n(End of clause)","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C25926R0082","place_of_performance":{"zip":"73104","city":{"name":"Oklahoma City"},"state":{"code":"OK"},"street":"Department of Veterans Affairs Oklahoma City VAMC 921 NE 13th St.","country":{"code":"USA"}},"product_service_code":"Z2DA"},{"dates":{"posted":"2026-07-09","posted_at":"2026-07-09T20:14:02.095Z","created_at":"2026-07-09T20:10:12.135Z","modified_at":"2026-07-09T20:14:02.098Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/7ca812dd89ba471aa0f2ad72f904143b/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-31","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:45:40.887Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","solicitation_number":"36C25926R0082","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":3,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:45:17.523Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"86fcf5bd787d4afebcb300ae64a81ceb","solicitation_number":"36C25926R0082","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":2,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:14:02.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b","solicitation_number":"36C25926R0082","parent_opportunity_id":"c324f341cde94b7ea40c253023b6b4ba"},{"index":1,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-06T21:00:26.063Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"c324f341cde94b7ea40c253023b6b4ba","solicitation_number":"36C25926R0082"}],"contacts":[{"name":"Christina Beeler-Blackburn","role":"primary","email":"christina.beeler-blackburn@va.gov","phone":"303-712-5744","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"7ca812dd89ba471aa0f2ad72f904143b","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"c324f341cde94b7ea40c253023b6b4ba","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T03:19:20.701028073Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"0c87f29668948154b2e8c0fd4c41021641240ea153f9ed5e55cfd500fc17fec6","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"<p>THIS IS A PRESOLICIATION NOTICE A REQUEST FOR PROPOSAL TO BE POSTED ON OR ABOUT JULY 20, 2026. Repair Parking Garage 1 Deficiencies (635-21-139) Oklahoma City VAMC 36C25926R0082 The Department of Veteran s Affairs has a requirement to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the OKC VA HCS at Oklahoma City, Oklahoma, 73104. The chosen contractor is to provide all materials and labor to complete all soil testing. The NAICS code for this procurement is 236220 with a small business size standard of $45.0 M. This project will be 100% set-aside for Small Businesses, as stated below. The POC for this project will be Christina Beeler-Blackburn. He can be contacted at 303-712-5744 or email at Christina.Beeler-Blackburn@va.gov. 852.219-73&Acirc;&nbsp; VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside. As prescribed in 819.7011, insert the following clause: VAAR 852.219-73 VA NOTICE OF TOTAL SET-ASIDE FOR CERTIFIED SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESSES (JAN 2023) (DEVIATION) (a)&Acirc;&nbsp;Definition.&Acirc;&nbsp;for the Department of Veterans Affairs, Service-disabled Veteran-owned small business concern or SDVOSB : (1) Means a small business concern - (i) Not less than 51 percent of which is owned by one or more service-disabled Veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled Veterans or eligible surviving spouses (see VAAR802.101, Surviving Spouse definition). (ii) The management and daily business operations of which are controlled by one or more service-disabled Veterans (or eligible surviving spouses) or, in the case of a service-disabled Veteran with permanent and severe disability, the spouse or permanent caregiver of such Veteran. (iii) The business meets Federal small business size standards for the applicable North American Industry Classification System (NAICS) code identified in the solicitation document. (iv) The business has been certified for ownership and control pursuant to 38 U.S.C. 8127, 13 CFR 128, and is listed as certified in the SBA certification database at https://veterans.certify.sba.gov/; and (v) The business agrees to comply with VAAR subpart 819.70 and Small Business Administration (SBA) regulations regarding small business size, government contracting, and the Veteran Small Business Certification Program at 13 CFR parts 121, 125, and 128. (2) The term Service-disabled Veteran means a Veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16). (3) The term small business concern has the meaning given that term under section 3 of the Small Business Act (15 U.S.C. 632). (4) The term small business concern owned and controlled by Veterans with service-connected disabilities has the meaning given the term small business concern owned and controlled by service-disabled veterans under section 3(q)(2) of the Small Business Act (15 U.S.C. 632(q)(2)). (5) The term SDVOSB participant or certified SDVOSB means a small business that has been certified in the SBA Veteran Small Business Certification Program and listed in the SBA certification database (see 13 CFR 128.102). (b) General. In order for a concern to submit an offer and be eligible for the award of an SDVOSB set-aside or sole source contract, the concern must qualify as a small business concern under the size standard corresponding to the NAICS code assigned to the contract and be listed as an SDVOSB participant in the SBA certification database as set forth in 13 CFR 128. (1) Offers received from entities that are not certified SDVOSBs and listed in the SBA certification database at the time of offer shall not be considered. (2) Any award resulting from this solicitation shall be made to a certified SDVOSB listed in the SBA certification database who is eligible at the time of submission of offer(s) and at the time of award. (3) The requirements in this clause apply to any contract, order, or subcontract where the firm receives a benefit or preference from its designation as an SDVOSB, including set-asides, sole source awards, and evaluation preferences. (c) Representation. Pursuant to 38 U.S.C. 8127(e), only certified SDVOSBs listed in the SBA certification database are considered eligible to receive award of a resulting contract. By submitting an offer, the prospective contractor represents that it is an eligible and certified SDVOSB as defined in this clause, 13 CFR 121, 125, and 128, and VAAR subpart 819.70. (d) Agreement/LOS certification. When awarded a contract action, including orders under multiple award contracts, an SDVOSB agrees that in the performance of the contract, the SDVOSB shall comply with requirements in VAAR subpart 819.70 and SBA regulations on small business size, and government contracting programs at 13 CFR part 121 and part 125, including the non-manufacturer rule and limitations on subcontracting (LOS) requirements in 13 CFR 121.406(b) and 13 CFR 125.6. For the purpose of limitations on subcontracting, only certified SDVOSBs listed in the SBA certification database (including independent contractors) shall be considered eligible and/or similarly situated (i.e., a firm that has the same small business program status as the prime contractor). An otherwise eligible firm further agrees to comply with the required LOS certification requirements in this solicitation (see 852.219 75 or 852.219 76 as applicable). These requirements are summarized as follows: (1) Services. In the case of a contract for services (except construction), the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance to firms that are not certified SDVOSBs listed in the SBA certification database (excluding direct costs to the extent they are not the principal purpose of the acquisition and the SDVOSB/ VOSB does not provide the service, such as airline travel, cloud computing services, or mass media purchases). When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract. (2)&Acirc;&nbsp;Supplies/products. (i) In the case of a contract for supplies or products (other than from a non-manufacturer of such supplies), the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, to firms that are not certified SDVOSBs listed in the SBA certification database. When a contract includes both supply and services, the 50 percent limitation shall apply only to the supply portion of the contract. (ii) In the case of a contract for supplies from a non-manufacturer, the SDVOSB prime contractor will supply the product of a domestic small business manufacturer or processor, unless a waiver as described in 13 CFR 121.406(b)(5) has been granted. Refer to 13 CFR 125.6(a)(2)(ii) for guidance pertaining to multiple item procurements. (3) General construction. In the case of a contract for general construction, the SDVOSB prime contractor will not pay more than 85% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, to firms that are not certified SDVOSBs listed in the SBA certification database. (4) Special trade construction contractors. In the case of a contract for special trade contractors, no more than 75% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, may be paid to firms that are not certified SDVOSBs listed in the SBA certification database. (5) Subcontracting. An SDVOSB subcontractor must meet the NAICS size standard assigned by the prime contractor and be certified and listed in the SBA certification database to count as similarly situated. Any work that a first tier SDVOSB subcontractor further subcontracts will count towards the percent of subcontract amount that cannot be exceeded. For supply or construction contracts, the cost of materials is excluded and not considered to be subcontracted. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the portion of the contract with the preponderance of the expenditure upon which the assigned NAICS is based. For information and more specific requirements, refer to 13 CFR 125.6. (e)&Acirc;&nbsp;Required limitations on subcontracting compliance measurement period.&Acirc;&nbsp;An SDVOSB shall comply with the limitations on subcontracting as follows: __By the end of the base term of the contract or order, and then by the end of each subsequent option period; or X_By the end of the performance period for each order issued under the contract. (f) Joint ventures. A joint venture may be considered eligible as an SDVOSB if the joint venture complies with the requirements in 13 CFR 128.402 and the managing joint venture partner makes the representations under paragraph (c) of this clause. A joint venture agrees that, in the performance of the contract, the applicable percentage specified in paragraph (d) of this clause will be performed by the aggregate of the joint venture participants. (g) Precedence. The VA Veterans First Contracting Program, as defined in VAAR 802.101, subpart 819.70, and this clause, takes precedence over any inconsistencies between the requirements of the SBA Veteran Small Business Certification Program and the VA Veterans First Contracting Program. (h) Misrepresentation. Pursuant to 38 U.S.C. 8127(g), any business concern, including all its principals, that is determined by VA to have willfully and intentionally misrepresented a company s SDVOSB status is subject to debarment from contracting with the Department for a period of not less than five years (see VAAR 809.406 2 Causes for Debarment). (End of clause)</p>","text":"THIS IS A PRESOLICIATION NOTICE A REQUEST FOR PROPOSAL TO BE POSTED ON OR ABOUT JULY 20, 2026. Repair Parking Garage 1 Deficiencies (635-21-139) Oklahoma City VAMC 36C25926R0082 The Department of Veteran s Affairs has a requirement to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the OKC VA HCS at Oklahoma City, Oklahoma, 73104. The chosen contractor is to provide all materials and labor to complete all soil testing. The NAICS code for this procurement is 236220 with a small business size standard of $45.0 M. This project will be 100% set-aside for Small Businesses, as stated below. The POC for this project will be Christina Beeler-Blackburn. He can be contacted at 303-712-5744 or email at Christina.Beeler-Blackburn@va.gov. 852.219-73Â VA Notice of Total Service-Disabled Veteran-Owned Small Business Set-Aside. As prescribed in 819.7011, insert the following clause: VAAR 852.219-73 VA NOTICE OF TOTAL SET-ASIDE FOR CERTIFIED SERVICE-DISABLED VETERAN-OWNED SMALL BUSINESSES (JAN 2023) (DEVIATION) (a)Â Definition.Â for the Department of Veterans Affairs, Service-disabled Veteran-owned small business concern or SDVOSB : (1) Means a small business concern - (i) Not less than 51 percent of which is owned by one or more service-disabled Veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled Veterans or eligible surviving spouses (see VAAR802.101, Surviving Spouse definition). (ii) The management and daily business operations of which are controlled by one or more service-disabled Veterans (or eligible surviving spouses) or, in the case of a service-disabled Veteran with permanent and severe disability, the spouse or permanent caregiver of such Veteran. (iii) The business meets Federal small business size standards for the applicable North American Industry Classification System (NAICS) code identified in the solicitation document. (iv) The business has been certified for ownership and control pursuant to 38 U.S.C. 8127, 13 CFR 128, and is listed as certified in the SBA certification database at https://veterans.certify.sba.gov/; and (v) The business agrees to comply with VAAR subpart 819.70 and Small Business Administration (SBA) regulations regarding small business size, government contracting, and the Veteran Small Business Certification Program at 13 CFR parts 121, 125, and 128. (2) The term Service-disabled Veteran means a Veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16). (3) The term small business concern has the meaning given that term under section 3 of the Small Business Act (15 U.S.C. 632). (4) The term small business concern owned and controlled by Veterans with service-connected disabilities has the meaning given the term small business concern owned and controlled by service-disabled veterans under section 3(q)(2) of the Small Business Act (15 U.S.C. 632(q)(2)). (5) The term SDVOSB participant or certified SDVOSB means a small business that has been certified in the SBA Veteran Small Business Certification Program and listed in the SBA certification database (see 13 CFR 128.102). (b) General. In order for a concern to submit an offer and be eligible for the award of an SDVOSB set-aside or sole source contract, the concern must qualify as a small business concern under the size standard corresponding to the NAICS code assigned to the contract and be listed as an SDVOSB participant in the SBA certification database as set forth in 13 CFR 128. (1) Offers received from entities that are not certified SDVOSBs and listed in the SBA certification database at the time of offer shall not be considered. (2) Any award resulting from this solicitation shall be made to a certified SDVOSB listed in the SBA certification database who is eligible at the time of submission of offer(s) and at the time of award. (3) The requirements in this clause apply to any contract, order, or subcontract where the firm receives a benefit or preference from its designation as an SDVOSB, including set-asides, sole source awards, and evaluation preferences. (c) Representation. Pursuant to 38 U.S.C. 8127(e), only certified SDVOSBs listed in the SBA certification database are considered eligible to receive award of a resulting contract. By submitting an offer, the prospective contractor represents that it is an eligible and certified SDVOSB as defined in this clause, 13 CFR 121, 125, and 128, and VAAR subpart 819.70. (d) Agreement/LOS certification. When awarded a contract action, including orders under multiple award contracts, an SDVOSB agrees that in the performance of the contract, the SDVOSB shall comply with requirements in VAAR subpart 819.70 and SBA regulations on small business size, and government contracting programs at 13 CFR part 121 and part 125, including the non-manufacturer rule and limitations on subcontracting (LOS) requirements in 13 CFR 121.406(b) and 13 CFR 125.6. For the purpose of limitations on subcontracting, only certified SDVOSBs listed in the SBA certification database (including independent contractors) shall be considered eligible and/or similarly situated (i.e., a firm that has the same small business program status as the prime contractor). An otherwise eligible firm further agrees to comply with the required LOS certification requirements in this solicitation (see 852.219 75 or 852.219 76 as applicable). These requirements are summarized as follows: (1) Services. In the case of a contract for services (except construction), the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance to firms that are not certified SDVOSBs listed in the SBA certification database (excluding direct costs to the extent they are not the principal purpose of the acquisition and the SDVOSB/ VOSB does not provide the service, such as airline travel, cloud computing services, or mass media purchases). When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract. (2)Â Supplies/products. (i) In the case of a contract for supplies or products (other than from a non-manufacturer of such supplies), the SDVOSB prime contractor will not pay more than 50% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, to firms that are not certified SDVOSBs listed in the SBA certification database. When a contract includes both supply and services, the 50 percent limitation shall apply only to the supply portion of the contract. (ii) In the case of a contract for supplies from a non-manufacturer, the SDVOSB prime contractor will supply the product of a domestic small business manufacturer or processor, unless a waiver as described in 13 CFR 121.406(b)(5) has been granted. Refer to 13 CFR 125.6(a)(2)(ii) for guidance pertaining to multiple item procurements. (3) General construction. In the case of a contract for general construction, the SDVOSB prime contractor will not pay more than 85% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, to firms that are not certified SDVOSBs listed in the SBA certification database. (4) Special trade construction contractors. In the case of a contract for special trade contractors, no more than 75% of the amount paid by the government to the prime for contract performance, excluding the cost of materials, may be paid to firms that are not certified SDVOSBs listed in the SBA certification database. (5) Subcontracting. An SDVOSB subcontractor must meet the NAICS size standard assigned by the prime contractor and be certified and listed in the SBA certification database to count as similarly situated. Any work that a first tier SDVOSB subcontractor further subcontracts will count towards the percent of subcontract amount that cannot be exceeded. For supply or construction contracts, the cost of materials is excluded and not considered to be subcontracted. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the portion of the contract with the preponderance of the expenditure upon which the assigned NAICS is based. For information and more specific requirements, refer to 13 CFR 125.6. (e)Â Required limitations on subcontracting compliance measurement period.Â An SDVOSB shall comply with the limitations on subcontracting as follows: __By the end of the base term of the contract or order, and then by the end of each subsequent option period; or X_By the end of the performance period for each order issued under the contract. (f) Joint ventures. A joint venture may be considered eligible as an SDVOSB if the joint venture complies with the requirements in 13 CFR 128.402 and the managing joint venture partner makes the representations under paragraph (c) of this clause. A joint venture agrees that, in the performance of the contract, the applicable percentage specified in paragraph (d) of this clause will be performed by the aggregate of the joint venture participants. (g) Precedence. The VA Veterans First Contracting Program, as defined in VAAR 802.101, subpart 819.70, and this clause, takes precedence over any inconsistencies between the requirements of the SBA Veteran Small Business Certification Program and the VA Veterans First Contracting Program. (h) Misrepresentation. Pursuant to 38 U.S.C. 8127(g), any business concern, including all its principals, that is determined by VA to have willfully and intentionally misrepresented a company s SDVOSB status is subject to debarment from contracting with the Department for a period of not less than five years (see VAAR 809.406 2 Causes for Debarment). (End of clause)","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C25926R0082","place_of_performance":{"zip":"73104","city":{"name":"Oklahoma City"},"state":{"code":"OK"},"street":"Department of Veterans Affairs Oklahoma City VAMC 921 NE 13th St.","country":{"code":"USA"}},"product_service_code":"Z2DA"},{"dates":{"posted":"2026-07-23","posted_at":"2026-07-23T21:45:17.523Z","created_at":"2026-07-23T21:44:47.631Z","modified_at":"2026-07-23T21:45:17.523Z","response_deadline":{"raw":"2026-08-20T11:30:00-05:00","utc":"2026-08-20T16:30:00Z","date":"2026-08-20","time":"11:30:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/86fcf5bd787d4afebcb300ae64a81ceb/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-11-18","archive_type":"auto_custom"},"history":[{"index":2,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:45:17.523Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"86fcf5bd787d4afebcb300ae64a81ceb","solicitation_number":"36C25926R0082","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":1,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:14:02.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b","solicitation_number":"36C25926R0082","parent_opportunity_id":"c324f341cde94b7ea40c253023b6b4ba"}],"contacts":[{"name":"Christina Beeler-Blackburn (CO)","role":"primary","email":"Christina.Beeler-Blackburn@va.gov","title":"Contract Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"86fcf5bd787d4afebcb300ae64a81ceb","lineage_id":"c324f341cde94b7ea40c253023b6b4ba","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T01:56:43.527084291Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"e14a4fdcbbf0bebbff734f5cff1f568bc24c412c905b83bae9f690807d58fdf2","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"Project 635-21-139, Repair Parking Garage 1 Deficiencies\n\nOBJECTIVE:\n\nThe purpose of the project is to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the VA Medical Center main building at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104.\n\nSCOPE OF WORK:\n\nThis summary is not intended to be all inclusive and does not absolve the contractor of responsibility to address the defects and deficiencies of the Parking Garage 1 consistent with the contents of the specs and/or drawings.  \nBidders are responsible for the entirety of the project scope described in the contract documents (drawings and specifications) and shall submit RFI s on any conflicts between drawings and specifications immediately that may impact bids.  \nBidders are responsible for all work specified or shown in the bid documents including the Statement of Work, Drawings, and Specifications.  \nWork includes but is not limited to the following: Parking striping and signage, fixing a sidewalk that is not ADA compliant, installing suicide prevention, providing a new stairwell on the south side of the parking garage.  \nCivil, architectural, electrical, lighting, wayfinding, low voltage, and structural systems are included in this project.  \n\nThe contractor shall comply with all requirements listed in the project solicitation including the construction drawings, the project specifications, and all solicitation amendments as may be issued. These documents will be followed during construction and shall be considered project requirements.\n\nThe areas adjacent to the proposed addition shall be continuously occupied by the OKC VAMC.  The Contractor shall implement phasing to ensure that the construction will not impact or impede the VAMC s mission to care for the Veterans. \n\nThe contractor shall provide quality control of all work conducted and the individual appointed shall be competent and educated/experienced in the field of work this scope encompasses.\n\nCodes and Standards: The Contractor shall follow all applicable codes and standards to this type of work including but not limited to Health Care System Memorandums (HCSM), OSHA Guidelines, NFPA 101, NFPA 70, Lock-out-Tag-out, and Rules of Station.\n\nPeriod of Performance: \n270 calendar days after Notice to Proceed (NTP). \n\nTask Management:\nEngineering shall identify a Contracting Officer s Representative (COR). The COR will provide technical assistance and clarification required for the performance of this contract, participate in project meetings, review invoices, and receive deliverables. After contract award, the Contracting Officer will appoint a COR and issue a COR appointment letter stating the authority for the COR. The contractor will receive a copy of the written appointment.\n\nThe Dept. of Veterans Affairs (VA) requires strict adherence to the Code of Federal Regulations 29, Part 1926. This includes the requirement that the prime contractor have a  Competent Person  known as site superintendent on the job at all times (must have a 30-hour OSHA card), and that all contractor and subcontractor employees have received a minimum of ten (10) hours of OSHA construction safety training. Documentation of these requirements shall be submitted and approved prior to performing the work.\n\nStorage and Security: \nContractor shall be responsible for storage and security of the project site at East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104. Contractor shall request Contracting Officer approve use bonded and insured off-site storage locations and COR shall access to view off-site stored materials and equipment. \n\nParking:\nContractor s personnel can park within project site, park on the fourth floor of the Parking Garage or utilize street parking in the neighborhood. Contractor shall not utilize adjacent parking lot for The Cathedral of Our Lady of Perpetual Help. Oklahoma City VA Medical Center shall not waive or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nWork Hours:\nConstruction shall be performed during normal working hours Monday   Fridays from 7:30 am to 3:30 pm excluding federal holidays unless requested and approved by the COR and 14-day notice is required. Federal holidays include:\n\nNew Year's Day    January 1st\nMartin Luther King's Birthday  Third Monday in January\nPresident's Day    Third Monday in February\nMemorial Day    Last Monday in May\nJuneteenth    June 19th\nIndependence Day   July 4th\nLabor Day     First Monday in September\nColumbus Day    Second Monday in October\nVeterans Day    November 11th\nThanksgiving Day    Fourth Thursday in November\nChristmas Day    December 25th\n\nWhen a holiday falls on a Sunday, the following Monday shall be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also, included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nDelivery Location: \nAll work related to this contract shall be performed at the Parking Garage 1 located East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104\n\nPayment Information:\nThe contractor shall provide the following payment information for VA use. It must be an exact match with the information under the contract number in the Contract Registration (not the contractor s company or individual representative s registration) as well as with the information under the contractor s DUNS number in the System Award for Management http://www.SAM.gov. Mismatched information will result in rejected invoice.\n\nCompany Name   Legal Business Name and DBA (Doing Business As) Name\nMailing Address   Contact and Address Information\nRemittance Address   Remit To Address Information\nEmployer s Identification Number   Federal Tax ID\nDUNS (Data Universal Numbering System)\n\nCODES, STANDARDS AND EXECUTIVE ORDERS:\n\nVA has adopted the latest edition of the following codes and standards as a minimum for all projects performed in the modernization, alteration, addition, or improvement of its real property and the construction of new structures. VA design Manuals and Master Specifications specify other codes and standards that VA follows on its projects:\n\nVA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).\nPG-18-1 Master Construction Specifications\nPG-18-3 Design and Construction Procedures\nPG-18-4 Standard Details and CAD Standards\nVA BIM Manual V2.2\nPG-18-5 Equipment Guide List\nH-18-8 VA Seismic Design Handbook\nPG-18-9 Space Planning Criteria\nPG-18-10 Design Manuals (by discipline)\nPG-18-12 Design Guides (graphical, by function)\nPG-18-13 Barrier Free Design Guides\nPG-18-14 Room Finishes, Door, and Hardware Schedules (consult COR for local standards)\nPG-18-15 Minimum Requirements for A/E Submissions\nPG-18-17 Environmental Compliance Manual\nH-7545 VA Cultural Resource Management\n\nVA Handbook 0056, Sustainable Building Program\nVA Directive 0056, Sustainable Building Program\nVA Directive 0055, VA Energy and Water Management Program \n\nNFPA 101 Life Safety Code \n\nNFPA National Fire Codes \n\nInternational Building Code (IBC) and all other International Code Series (IPC, IMC, IECC, IFGC, etc.) when applicable or referenced in VA Design documents/ guides.  \n\nOccupational, Safety and Health Administration (OSHA) Standards.\n\nNational Electrical Code (NEC)\n\nSafety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.\n\nASME Boiler and Pressure Vessel Code\n\nASME Code for Pressure Piping\n\nArchitectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)\n\nBuilding Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)\n\nManual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)\n\nEnergy policy Act of 2007 (EPAct)\n\nDOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High-Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.\n\nFederal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)\n\nExecutive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.\n\nThe Provisions for Construction and Safety Signs.  Stated in the General Requirements Section 01010 of the VA Master Construction Specification.\n\nVentilation for Acceptable Indoor Air Quality   ASHRAE Standard 62.1- 2013.\n\nSafety Standard for Refrigeration Systems   ASHRAE Standard 15   2016.","text":"Project 635-21-139, Repair Parking Garage 1 Deficiencies\n\nOBJECTIVE:\n\nThe purpose of the project is to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the VA Medical Center main building at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104.\n\nSCOPE OF WORK:\n\nThis summary is not intended to be all inclusive and does not absolve the contractor of responsibility to address the defects and deficiencies of the Parking Garage 1 consistent with the contents of the specs and/or drawings.\nBidders are responsible for the entirety of the project scope described in the contract documents (drawings and specifications) and shall submit RFI s on any conflicts between drawings and specifications immediately that may impact bids.\nBidders are responsible for all work specified or shown in the bid documents including the Statement of Work, Drawings, and Specifications.\nWork includes but is not limited to the following: Parking striping and signage, fixing a sidewalk that is not ADA compliant, installing suicide prevention, providing a new stairwell on the south side of the parking garage.\nCivil, architectural, electrical, lighting, wayfinding, low voltage, and structural systems are included in this project.\n\nThe contractor shall comply with all requirements listed in the project solicitation including the construction drawings, the project specifications, and all solicitation amendments as may be issued. These documents will be followed during construction and shall be considered project requirements.\n\nThe areas adjacent to the proposed addition shall be continuously occupied by the OKC VAMC. The Contractor shall implement phasing to ensure that the construction will not impact or impede the VAMC s mission to care for the Veterans.\n\nThe contractor shall provide quality control of all work conducted and the individual appointed shall be competent and educated/experienced in the field of work this scope encompasses.\n\nCodes and Standards: The Contractor shall follow all applicable codes and standards to this type of work including but not limited to Health Care System Memorandums (HCSM), OSHA Guidelines, NFPA 101, NFPA 70, Lock-out-Tag-out, and Rules of Station.\n\nPeriod of Performance:\n270 calendar days after Notice to Proceed (NTP).\n\nTask Management:\nEngineering shall identify a Contracting Officer s Representative (COR). The COR will provide technical assistance and clarification required for the performance of this contract, participate in project meetings, review invoices, and receive deliverables. After contract award, the Contracting Officer will appoint a COR and issue a COR appointment letter stating the authority for the COR. The contractor will receive a copy of the written appointment.\n\nThe Dept. of Veterans Affairs (VA) requires strict adherence to the Code of Federal Regulations 29, Part 1926. This includes the requirement that the prime contractor have a Competent Person known as site superintendent on the job at all times (must have a 30-hour OSHA card), and that all contractor and subcontractor employees have received a minimum of ten (10) hours of OSHA construction safety training. Documentation of these requirements shall be submitted and approved prior to performing the work.\n\nStorage and Security:\nContractor shall be responsible for storage and security of the project site at East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104. Contractor shall request Contracting Officer approve use bonded and insured off-site storage locations and COR shall access to view off-site stored materials and equipment.\n\nParking:\nContractor s personnel can park within project site, park on the fourth floor of the Parking Garage or utilize street parking in the neighborhood. Contractor shall not utilize adjacent parking lot for The Cathedral of Our Lady of Perpetual Help. Oklahoma City VA Medical Center shall not waive or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nWork Hours:\nConstruction shall be performed during normal working hours Monday Fridays from 7:30 am to 3:30 pm excluding federal holidays unless requested and approved by the COR and 14-day notice is required. Federal holidays include:\n\nNew Year's Day January 1st\nMartin Luther King's Birthday Third Monday in January\nPresident's Day Third Monday in February\nMemorial Day Last Monday in May\nJuneteenth June 19th\nIndependence Day July 4th\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nVeterans Day November 11th\nThanksgiving Day Fourth Thursday in November\nChristmas Day December 25th\n\nWhen a holiday falls on a Sunday, the following Monday shall be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also, included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nDelivery Location:\nAll work related to this contract shall be performed at the Parking Garage 1 located East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104\n\nPayment Information:\nThe contractor shall provide the following payment information for VA use. It must be an exact match with the information under the contract number in the Contract Registration (not the contractor s company or individual representative s registration) as well as with the information under the contractor s DUNS number in the System Award for Management http://www.SAM.gov. Mismatched information will result in rejected invoice.\n\nCompany Name Legal Business Name and DBA (Doing Business As) Name\nMailing Address Contact and Address Information\nRemittance Address Remit To Address Information\nEmployer s Identification Number Federal Tax ID\nDUNS (Data Universal Numbering System)\n\nCODES, STANDARDS AND EXECUTIVE ORDERS:\n\nVA has adopted the latest edition of the following codes and standards as a minimum for all projects performed in the modernization, alteration, addition, or improvement of its real property and the construction of new structures. VA design Manuals and Master Specifications specify other codes and standards that VA follows on its projects:\n\nVA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).\nPG-18-1 Master Construction Specifications\nPG-18-3 Design and Construction Procedures\nPG-18-4 Standard Details and CAD Standards\nVA BIM Manual V2.2\nPG-18-5 Equipment Guide List\nH-18-8 VA Seismic Design Handbook\nPG-18-9 Space Planning Criteria\nPG-18-10 Design Manuals (by discipline)\nPG-18-12 Design Guides (graphical, by function)\nPG-18-13 Barrier Free Design Guides\nPG-18-14 Room Finishes, Door, and Hardware Schedules (consult COR for local standards)\nPG-18-15 Minimum Requirements for A/E Submissions\nPG-18-17 Environmental Compliance Manual\nH-7545 VA Cultural Resource Management\n\nVA Handbook 0056, Sustainable Building Program\nVA Directive 0056, Sustainable Building Program\nVA Directive 0055, VA Energy and Water Management Program\n\nNFPA 101 Life Safety Code\n\nNFPA National Fire Codes\n\nInternational Building Code (IBC) and all other International Code Series (IPC, IMC, IECC, IFGC, etc.) when applicable or referenced in VA Design documents/ guides.\n\nOccupational, Safety and Health Administration (OSHA) Standards.\n\nNational Electrical Code (NEC)\n\nSafety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.\n\nASME Boiler and Pressure Vessel Code\n\nASME Code for Pressure Piping\n\nArchitectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)\n\nBuilding Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)\n\nManual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)\n\nEnergy policy Act of 2007 (EPAct)\n\nDOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High-Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.\n\nFederal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)\n\nExecutive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.\n\nThe Provisions for Construction and Safety Signs. Stated in the General Requirements Section 01010 of the VA Master Construction Specification.\n\nVentilation for Acceptable Indoor Air Quality ASHRAE Standard 62.1- 2013.\n\nSafety Standard for Refrigeration Systems ASHRAE Standard 15 2016.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25926R0082","product_service_code":"Z2DA"},{"dates":{"posted":"2026-07-23","posted_at":"2026-07-23T21:45:40.887Z","created_at":"2026-07-23T21:45:02.270Z","modified_at":"2026-07-23T21:54:30.945Z","response_deadline":{"raw":"2026-08-20T11:30:00-05:00","utc":"2026-08-20T16:30:00Z","date":"2026-08-20","time":"11:30:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9e657e02f23344be9cb2e0c95731db1b/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","agency":{"office":{"code":"36C259","name":"NETWORK CONTRACT OFFICE 19 (36C259)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2026-11-18","archive_type":"auto_custom"},"history":[{"index":8,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-16T19:23:48.690Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a3ea647d83c24bd4a774806d66ad4c7d","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":7,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-01T22:19:35.274Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"39fed56ba8e042d88455e8f5b266081a","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":6,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-20T14:18:38.537Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c45d073761be4dd98b335f269ad2fa54","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":5,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-17T17:07:32.595Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ea94c40ad665440b92ff7882dfef8fae","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":4,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-08-11T20:23:59.037Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"48f21172474c4577b35f98880e4c5a97","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":3,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:54:30.945Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f0a1bec4350c4c309a4d8fb3d1030050","solicitation_number":"36C25926R0082_1","parent_opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":2,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-23T21:45:40.887Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e657e02f23344be9cb2e0c95731db1b","solicitation_number":"36C25926R0082","related_opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b"},{"index":1,"title":"Z2DA--635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-07-09T20:14:02.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"7ca812dd89ba471aa0f2ad72f904143b","solicitation_number":"36C25926R0082","parent_opportunity_id":"c324f341cde94b7ea40c253023b6b4ba"}],"contacts":[{"name":"Christina Beeler-Blackburn (CO)","role":"primary","email":"Christina.Beeler-Blackburn@va.gov","title":"Contract Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"9e657e02f23344be9cb2e0c95731db1b","lineage_id":"9e657e02f23344be9cb2e0c95731db1b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T01:57:56.521822080Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"b0c0b98573e76d9ab3638c55d5fdb0d13eae9fb833fcbe66eae5b0239b8b8f1f","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"Project 635-21-139, Repair Parking Garage 1 Deficiencies\n\nOBJECTIVE:\n\nThe purpose of the project is to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the VA Medical Center main building at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104.\n\nSCOPE OF WORK:\n\nThis summary is not intended to be all inclusive and does not absolve the contractor of responsibility to address the defects and deficiencies of the Parking Garage 1 consistent with the contents of the specs and/or drawings.  \nBidders are responsible for the entirety of the project scope described in the contract documents (drawings and specifications) and shall submit RFI s on any conflicts between drawings and specifications immediately that may impact bids.  \nBidders are responsible for all work specified or shown in the bid documents including the Statement of Work, Drawings, and Specifications.  \nWork includes but is not limited to the following: Parking striping and signage, fixing a sidewalk that is not ADA compliant, installing suicide prevention, providing a new stairwell on the south side of the parking garage.  \nCivil, architectural, electrical, lighting, wayfinding, low voltage, and structural systems are included in this project.  \n\nThe contractor shall comply with all requirements listed in the project solicitation including the construction drawings, the project specifications, and all solicitation amendments as may be issued. These documents will be followed during construction and shall be considered project requirements.\n\nThe areas adjacent to the proposed addition shall be continuously occupied by the OKC VAMC.  The Contractor shall implement phasing to ensure that the construction will not impact or impede the VAMC s mission to care for the Veterans. \n\nThe contractor shall provide quality control of all work conducted and the individual appointed shall be competent and educated/experienced in the field of work this scope encompasses.\n\nCodes and Standards: The Contractor shall follow all applicable codes and standards to this type of work including but not limited to Health Care System Memorandums (HCSM), OSHA Guidelines, NFPA 101, NFPA 70, Lock-out-Tag-out, and Rules of Station.\n\nPeriod of Performance: \n270 calendar days after Notice to Proceed (NTP). \n\nTask Management:\nEngineering shall identify a Contracting Officer s Representative (COR). The COR will provide technical assistance and clarification required for the performance of this contract, participate in project meetings, review invoices, and receive deliverables. After contract award, the Contracting Officer will appoint a COR and issue a COR appointment letter stating the authority for the COR. The contractor will receive a copy of the written appointment.\n\nThe Dept. of Veterans Affairs (VA) requires strict adherence to the Code of Federal Regulations 29, Part 1926. This includes the requirement that the prime contractor have a  Competent Person  known as site superintendent on the job at all times (must have a 30-hour OSHA card), and that all contractor and subcontractor employees have received a minimum of ten (10) hours of OSHA construction safety training. Documentation of these requirements shall be submitted and approved prior to performing the work.\n\nStorage and Security: \nContractor shall be responsible for storage and security of the project site at East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104. Contractor shall request Contracting Officer approve use bonded and insured off-site storage locations and COR shall access to view off-site stored materials and equipment. \n\nParking:\nContractor s personnel can park within project site, park on the fourth floor of the Parking Garage or utilize street parking in the neighborhood. Contractor shall not utilize adjacent parking lot for The Cathedral of Our Lady of Perpetual Help. Oklahoma City VA Medical Center shall not waive or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nWork Hours:\nConstruction shall be performed during normal working hours Monday   Fridays from 7:30 am to 3:30 pm excluding federal holidays unless requested and approved by the COR and 14-day notice is required. Federal holidays include:\n\nNew Year's Day    January 1st\nMartin Luther King's Birthday  Third Monday in January\nPresident's Day    Third Monday in February\nMemorial Day    Last Monday in May\nJuneteenth    June 19th\nIndependence Day   July 4th\nLabor Day     First Monday in September\nColumbus Day    Second Monday in October\nVeterans Day    November 11th\nThanksgiving Day    Fourth Thursday in November\nChristmas Day    December 25th\n\nWhen a holiday falls on a Sunday, the following Monday shall be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also, included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nDelivery Location: \nAll work related to this contract shall be performed at the Parking Garage 1 located East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104\n\nPayment Information:\nThe contractor shall provide the following payment information for VA use. It must be an exact match with the information under the contract number in the Contract Registration (not the contractor s company or individual representative s registration) as well as with the information under the contractor s DUNS number in the System Award for Management http://www.SAM.gov. Mismatched information will result in rejected invoice.\n\nCompany Name   Legal Business Name and DBA (Doing Business As) Name\nMailing Address   Contact and Address Information\nRemittance Address   Remit To Address Information\nEmployer s Identification Number   Federal Tax ID\nDUNS (Data Universal Numbering System)\n\nCODES, STANDARDS AND EXECUTIVE ORDERS:\n\nVA has adopted the latest edition of the following codes and standards as a minimum for all projects performed in the modernization, alteration, addition, or improvement of its real property and the construction of new structures. VA design Manuals and Master Specifications specify other codes and standards that VA follows on its projects:\n\nVA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).\nPG-18-1 Master Construction Specifications\nPG-18-3 Design and Construction Procedures\nPG-18-4 Standard Details and CAD Standards\nVA BIM Manual V2.2\nPG-18-5 Equipment Guide List\nH-18-8 VA Seismic Design Handbook\nPG-18-9 Space Planning Criteria\nPG-18-10 Design Manuals (by discipline)\nPG-18-12 Design Guides (graphical, by function)\nPG-18-13 Barrier Free Design Guides\nPG-18-14 Room Finishes, Door, and Hardware Schedules (consult COR for local standards)\nPG-18-15 Minimum Requirements for A/E Submissions\nPG-18-17 Environmental Compliance Manual\nH-7545 VA Cultural Resource Management\n\nVA Handbook 0056, Sustainable Building Program\nVA Directive 0056, Sustainable Building Program\nVA Directive 0055, VA Energy and Water Management Program \n\nNFPA 101 Life Safety Code \n\nNFPA National Fire Codes \n\nInternational Building Code (IBC) and all other International Code Series (IPC, IMC, IECC, IFGC, etc.) when applicable or referenced in VA Design documents/ guides.  \n\nOccupational, Safety and Health Administration (OSHA) Standards.\n\nNational Electrical Code (NEC)\n\nSafety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.\n\nASME Boiler and Pressure Vessel Code\n\nASME Code for Pressure Piping\n\nArchitectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)\n\nBuilding Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)\n\nManual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)\n\nEnergy policy Act of 2007 (EPAct)\n\nDOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High-Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.\n\nFederal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)\n\nExecutive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.\n\nThe Provisions for Construction and Safety Signs.  Stated in the General Requirements Section 01010 of the VA Master Construction Specification.\n\nVentilation for Acceptable Indoor Air Quality   ASHRAE Standard 62.1- 2013.\n\nSafety Standard for Refrigeration Systems   ASHRAE Standard 15   2016.","text":"Project 635-21-139, Repair Parking Garage 1 Deficiencies\n\nOBJECTIVE:\n\nThe purpose of the project is to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the VA Medical Center main building at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104.\n\nSCOPE OF WORK:\n\nThis summary is not intended to be all inclusive and does not absolve the contractor of responsibility to address the defects and deficiencies of the Parking Garage 1 consistent with the contents of the specs and/or drawings.\nBidders are responsible for the entirety of the project scope described in the contract documents (drawings and specifications) and shall submit RFI s on any conflicts between drawings and specifications immediately that may impact bids.\nBidders are responsible for all work specified or shown in the bid documents including the Statement of Work, Drawings, and Specifications.\nWork includes but is not limited to the following: Parking striping and signage, fixing a sidewalk that is not ADA compliant, installing suicide prevention, providing a new stairwell on the south side of the parking garage.\nCivil, architectural, electrical, lighting, wayfinding, low voltage, and structural systems are included in this project.\n\nThe contractor shall comply with all requirements listed in the project solicitation including the construction drawings, the project specifications, and all solicitation amendments as may be issued. These documents will be followed during construction and shall be considered project requirements.\n\nThe areas adjacent to the proposed addition shall be continuously occupied by the OKC VAMC. The Contractor shall implement phasing to ensure that the construction will not impact or impede the VAMC s mission to care for the Veterans.\n\nThe contractor shall provide quality control of all work conducted and the individual appointed shall be competent and educated/experienced in the field of work this scope encompasses.\n\nCodes and Standards: The Contractor shall follow all applicable codes and standards to this type of work including but not limited to Health Care System Memorandums (HCSM), OSHA Guidelines, NFPA 101, NFPA 70, Lock-out-Tag-out, and Rules of Station.\n\nPeriod of Performance:\n270 calendar days after Notice to Proceed (NTP).\n\nTask Management:\nEngineering shall identify a Contracting Officer s Representative (COR). The COR will provide technical assistance and clarification required for the performance of this contract, participate in project meetings, review invoices, and receive deliverables. After contract award, the Contracting Officer will appoint a COR and issue a COR appointment letter stating the authority for the COR. The contractor will receive a copy of the written appointment.\n\nThe Dept. of Veterans Affairs (VA) requires strict adherence to the Code of Federal Regulations 29, Part 1926. This includes the requirement that the prime contractor have a Competent Person known as site superintendent on the job at all times (must have a 30-hour OSHA card), and that all contractor and subcontractor employees have received a minimum of ten (10) hours of OSHA construction safety training. Documentation of these requirements shall be submitted and approved prior to performing the work.\n\nStorage and Security:\nContractor shall be responsible for storage and security of the project site at East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104. Contractor shall request Contracting Officer approve use bonded and insured off-site storage locations and COR shall access to view off-site stored materials and equipment.\n\nParking:\nContractor s personnel can park within project site, park on the fourth floor of the Parking Garage or utilize street parking in the neighborhood. Contractor shall not utilize adjacent parking lot for The Cathedral of Our Lady of Perpetual Help. Oklahoma City VA Medical Center shall not waive or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nWork Hours:\nConstruction shall be performed during normal working hours Monday Fridays from 7:30 am to 3:30 pm excluding federal holidays unless requested and approved by the COR and 14-day notice is required. Federal holidays include:\n\nNew Year's Day January 1st\nMartin Luther King's Birthday Third Monday in January\nPresident's Day Third Monday in February\nMemorial Day Last Monday in May\nJuneteenth June 19th\nIndependence Day July 4th\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nVeterans Day November 11th\nThanksgiving Day Fourth Thursday in November\nChristmas Day December 25th\n\nWhen a holiday falls on a Sunday, the following Monday shall be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also, included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nDelivery Location:\nAll work related to this contract shall be performed at the Parking Garage 1 located East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104\n\nPayment Information:\nThe contractor shall provide the following payment information for VA use. It must be an exact match with the information under the contract number in the Contract Registration (not the contractor s company or individual representative s registration) as well as with the information under the contractor s DUNS number in the System Award for Management http://www.SAM.gov. Mismatched information will result in rejected invoice.\n\nCompany Name Legal Business Name and DBA (Doing Business As) Name\nMailing Address Contact and Address Information\nRemittance Address Remit To Address Information\nEmployer s Identification Number Federal Tax ID\nDUNS (Data Universal Numbering System)\n\nCODES, STANDARDS AND EXECUTIVE ORDERS:\n\nVA has adopted the latest edition of the following codes and standards as a minimum for all projects performed in the modernization, alteration, addition, or improvement of its real property and the construction of new structures. VA design Manuals and Master Specifications specify other codes and standards that VA follows on its projects:\n\nVA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).\nPG-18-1 Master Construction Specifications\nPG-18-3 Design and Construction Procedures\nPG-18-4 Standard Details and CAD Standards\nVA BIM Manual V2.2\nPG-18-5 Equipment Guide List\nH-18-8 VA Seismic Design Handbook\nPG-18-9 Space Planning Criteria\nPG-18-10 Design Manuals (by discipline)\nPG-18-12 Design Guides (graphical, by function)\nPG-18-13 Barrier Free Design Guides\nPG-18-14 Room Finishes, Door, and Hardware Schedules (consult COR for local standards)\nPG-18-15 Minimum Requirements for A/E Submissions\nPG-18-17 Environmental Compliance Manual\nH-7545 VA Cultural Resource Management\n\nVA Handbook 0056, Sustainable Building Program\nVA Directive 0056, Sustainable Building Program\nVA Directive 0055, VA Energy and Water Management Program\n\nNFPA 101 Life Safety Code\n\nNFPA National Fire Codes\n\nInternational Building Code (IBC) and all other International Code Series (IPC, IMC, IECC, IFGC, etc.) when applicable or referenced in VA Design documents/ guides.\n\nOccupational, Safety and Health Administration (OSHA) Standards.\n\nNational Electrical Code (NEC)\n\nSafety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.\n\nASME Boiler and Pressure Vessel Code\n\nASME Code for Pressure Piping\n\nArchitectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)\n\nBuilding Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)\n\nManual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)\n\nEnergy policy Act of 2007 (EPAct)\n\nDOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High-Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.\n\nFederal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)\n\nExecutive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.\n\nThe Provisions for Construction and Safety Signs. Stated in the General Requirements Section 01010 of the VA Master Construction Specification.\n\nVentilation for Acceptable Indoor Air Quality ASHRAE Standard 62.1- 2013.\n\nSafety Standard for Refrigeration Systems ASHRAE Standard 15 2016.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C25926R0082","product_service_code":"Z2DA"}],"due_at":"2026-08-20T16:30:00Z","due_date":"2026-08-20","closes_at":"2026-08-20T16:30:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-24T03:25:58.922164Z","principal_notice_id":"9e657e02f23344be9cb2e0c95731db1b","description":{"text":"Project 635-21-139, Repair Parking Garage 1 Deficiencies\n\nOBJECTIVE:\n\nThe purpose of the project is to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the VA Medical Center main building at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104.\n\nSCOPE OF WORK:\n\nThis summary is not intended to be all inclusive and does not absolve the contractor of responsibility to address the defects and deficiencies of the Parking Garage 1 consistent with the contents of the specs and/or drawings.\nBidders are responsible for the entirety of the project scope described in the contract documents (drawings and specifications) and shall submit RFI s on any conflicts between drawings and specifications immediately that may impact bids.\nBidders are responsible for all work specified or shown in the bid documents including the Statement of Work, Drawings, and Specifications.\nWork includes but is not limited to the following: Parking striping and signage, fixing a sidewalk that is not ADA compliant, installing suicide prevention, providing a new stairwell on the south side of the parking garage.\nCivil, architectural, electrical, lighting, wayfinding, low voltage, and structural systems are included in this project.\n\nThe contractor shall comply with all requirements listed in the project solicitation including the construction drawings, the project specifications, and all solicitation amendments as may be issued. These documents will be followed during construction and shall be considered project requirements.\n\nThe areas adjacent to the proposed addition shall be continuously occupied by the OKC VAMC. The Contractor shall implement phasing to ensure that the construction will not impact or impede the VAMC s mission to care for the Veterans.\n\nThe contractor shall provide quality control of all work conducted and the individual appointed shall be competent and educated/experienced in the field of work this scope encompasses.\n\nCodes and Standards: The Contractor shall follow all applicable codes and standards to this type of work including but not limited to Health Care System Memorandums (HCSM), OSHA Guidelines, NFPA 101, NFPA 70, Lock-out-Tag-out, and Rules of Station.\n\nPeriod of Performance:\n270 calendar days after Notice to Proceed (NTP).\n\nTask Management:\nEngineering shall identify a Contracting Officer s Representative (COR). The COR will provide technical assistance and clarification required for the performance of this contract, participate in project meetings, review invoices, and receive deliverables. After contract award, the Contracting Officer will appoint a COR and issue a COR appointment letter stating the authority for the COR. The contractor will receive a copy of the written appointment.\n\nThe Dept. of Veterans Affairs (VA) requires strict adherence to the Code of Federal Regulations 29, Part 1926. This includes the requirement that the prime contractor have a Competent Person known as site superintendent on the job at all times (must have a 30-hour OSHA card), and that all contractor and subcontractor employees have received a minimum of ten (10) hours of OSHA construction safety training. Documentation of these requirements shall be submitted and approved prior to performing the work.\n\nStorage and Security:\nContractor shall be responsible for storage and security of the project site at East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104. Contractor shall request Contracting Officer approve use bonded and insured off-site storage locations and COR shall access to view off-site stored materials and equipment.\n\nParking:\nContractor s personnel can park within project site, park on the fourth floor of the Parking Garage or utilize street parking in the neighborhood. Contractor shall not utilize adjacent parking lot for The Cathedral of Our Lady of Perpetual Help. Oklahoma City VA Medical Center shall not waive or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nWork Hours:\nConstruction shall be performed during normal working hours Monday Fridays from 7:30 am to 3:30 pm excluding federal holidays unless requested and approved by the COR and 14-day notice is required. Federal holidays include:\n\nNew Year's Day January 1st\nMartin Luther King's Birthday Third Monday in January\nPresident's Day Third Monday in February\nMemorial Day Last Monday in May\nJuneteenth June 19th\nIndependence Day July 4th\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nVeterans Day November 11th\nThanksgiving Day Fourth Thursday in November\nChristmas Day December 25th\n\nWhen a holiday falls on a Sunday, the following Monday shall be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also, included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nDelivery Location:\nAll work related to this contract shall be performed at the Parking Garage 1 located East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104\n\nPayment Information:\nThe contractor shall provide the following payment information for VA use. It must be an exact match with the information under the contract number in the Contract Registration (not the contractor s company or individual representative s registration) as well as with the information under the contractor s DUNS number in the System Award for Management http://www.SAM.gov. Mismatched information will result in rejected invoice.\n\nCompany Name Legal Business Name and DBA (Doing Business As) Name\nMailing Address Contact and Address Information\nRemittance Address Remit To Address Information\nEmployer s Identification Number Federal Tax ID\nDUNS (Data Universal Numbering System)\n\nCODES, STANDARDS AND EXECUTIVE ORDERS:\n\nVA has adopted the latest edition of the following codes and standards as a minimum for all projects performed in the modernization, alteration, addition, or improvement of its real property and the construction of new structures. VA design Manuals and Master Specifications specify other codes and standards that VA follows on its projects:\n\nVA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).\nPG-18-1 Master Construction Specifications\nPG-18-3 Design and Construction Procedures\nPG-18-4 Standard Details and CAD Standards\nVA BIM Manual V2.2\nPG-18-5 Equipment Guide List\nH-18-8 VA Seismic Design Handbook\nPG-18-9 Space Planning Criteria\nPG-18-10 Design Manuals (by discipline)\nPG-18-12 Design Guides (graphical, by function)\nPG-18-13 Barrier Free Design Guides\nPG-18-14 Room Finishes, Door, and Hardware Schedules (consult COR for local standards)\nPG-18-15 Minimum Requirements for A/E Submissions\nPG-18-17 Environmental Compliance Manual\nH-7545 VA Cultural Resource Management\n\nVA Handbook 0056, Sustainable Building Program\nVA Directive 0056, Sustainable Building Program\nVA Directive 0055, VA Energy and Water Management Program\n\nNFPA 101 Life Safety Code\n\nNFPA National Fire Codes\n\nInternational Building Code (IBC) and all other International Code Series (IPC, IMC, IECC, IFGC, etc.) when applicable or referenced in VA Design documents/ guides.\n\nOccupational, Safety and Health Administration (OSHA) Standards.\n\nNational Electrical Code (NEC)\n\nSafety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.\n\nASME Boiler and Pressure Vessel Code\n\nASME Code for Pressure Piping\n\nArchitectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)\n\nBuilding Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)\n\nManual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)\n\nEnergy policy Act of 2007 (EPAct)\n\nDOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High-Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.\n\nFederal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)\n\nExecutive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.\n\nThe Provisions for Construction and Safety Signs. Stated in the General Requirements Section 01010 of the VA Master Construction Specification.\n\nVentilation for Acceptable Indoor Air Quality ASHRAE Standard 62.1- 2013.\n\nSafety Standard for Refrigeration Systems ASHRAE Standard 15 2016.","html":"Project 635-21-139, Repair Parking Garage 1 Deficiencies\n\nOBJECTIVE:\n\nThe purpose of the project is to address the defects and deficiencies of the existing Parking Garage 1. The contractor shall furnish all equipment, materials, labor, supervision, and quality control to perform work for VA Project 635-21-139 Repair Parking Garage 1 Deficiencies located East of the VA Medical Center main building at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104.\n\nSCOPE OF WORK:\n\nThis summary is not intended to be all inclusive and does not absolve the contractor of responsibility to address the defects and deficiencies of the Parking Garage 1 consistent with the contents of the specs and/or drawings.  \nBidders are responsible for the entirety of the project scope described in the contract documents (drawings and specifications) and shall submit RFI s on any conflicts between drawings and specifications immediately that may impact bids.  \nBidders are responsible for all work specified or shown in the bid documents including the Statement of Work, Drawings, and Specifications.  \nWork includes but is not limited to the following: Parking striping and signage, fixing a sidewalk that is not ADA compliant, installing suicide prevention, providing a new stairwell on the south side of the parking garage.  \nCivil, architectural, electrical, lighting, wayfinding, low voltage, and structural systems are included in this project.  \n\nThe contractor shall comply with all requirements listed in the project solicitation including the construction drawings, the project specifications, and all solicitation amendments as may be issued. These documents will be followed during construction and shall be considered project requirements.\n\nThe areas adjacent to the proposed addition shall be continuously occupied by the OKC VAMC.  The Contractor shall implement phasing to ensure that the construction will not impact or impede the VAMC s mission to care for the Veterans. \n\nThe contractor shall provide quality control of all work conducted and the individual appointed shall be competent and educated/experienced in the field of work this scope encompasses.\n\nCodes and Standards: The Contractor shall follow all applicable codes and standards to this type of work including but not limited to Health Care System Memorandums (HCSM), OSHA Guidelines, NFPA 101, NFPA 70, Lock-out-Tag-out, and Rules of Station.\n\nPeriod of Performance: \n270 calendar days after Notice to Proceed (NTP). \n\nTask Management:\nEngineering shall identify a Contracting Officer s Representative (COR). The COR will provide technical assistance and clarification required for the performance of this contract, participate in project meetings, review invoices, and receive deliverables. After contract award, the Contracting Officer will appoint a COR and issue a COR appointment letter stating the authority for the COR. The contractor will receive a copy of the written appointment.\n\nThe Dept. of Veterans Affairs (VA) requires strict adherence to the Code of Federal Regulations 29, Part 1926. This includes the requirement that the prime contractor have a  Competent Person  known as site superintendent on the job at all times (must have a 30-hour OSHA card), and that all contractor and subcontractor employees have received a minimum of ten (10) hours of OSHA construction safety training. Documentation of these requirements shall be submitted and approved prior to performing the work.\n\nStorage and Security: \nContractor shall be responsible for storage and security of the project site at East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104. Contractor shall request Contracting Officer approve use bonded and insured off-site storage locations and COR shall access to view off-site stored materials and equipment. \n\nParking:\nContractor s personnel can park within project site, park on the fourth floor of the Parking Garage or utilize street parking in the neighborhood. Contractor shall not utilize adjacent parking lot for The Cathedral of Our Lady of Perpetual Help. Oklahoma City VA Medical Center shall not waive or make reimbursement for parking violations of the Contractor s personnel under any circumstances.\n\nWork Hours:\nConstruction shall be performed during normal working hours Monday   Fridays from 7:30 am to 3:30 pm excluding federal holidays unless requested and approved by the COR and 14-day notice is required. Federal holidays include:\n\nNew Year's Day    January 1st\nMartin Luther King's Birthday  Third Monday in January\nPresident's Day    Third Monday in February\nMemorial Day    Last Monday in May\nJuneteenth    June 19th\nIndependence Day   July 4th\nLabor Day     First Monday in September\nColumbus Day    Second Monday in October\nVeterans Day    November 11th\nThanksgiving Day    Fourth Thursday in November\nChristmas Day    December 25th\n\nWhen a holiday falls on a Sunday, the following Monday shall be observed as a legal holiday. When a holiday falls on a Saturday, the preceding Friday is observed as a legal holiday by U.S. Government agencies. Also, included, would be any other day specifically declared by the President of the United States of America to be a National Holiday.\n\nDelivery Location: \nAll work related to this contract shall be performed at the Parking Garage 1 located East of the VA Medical Center main building (921 NE 13th Street, Oklahoma City, Oklahoma 73104) at the corner of NE 13th street and N. Kelly Avenue, Oklahoma City, Oklahoma 73104\n\nPayment Information:\nThe contractor shall provide the following payment information for VA use. It must be an exact match with the information under the contract number in the Contract Registration (not the contractor s company or individual representative s registration) as well as with the information under the contractor s DUNS number in the System Award for Management http://www.SAM.gov. Mismatched information will result in rejected invoice.\n\nCompany Name   Legal Business Name and DBA (Doing Business As) Name\nMailing Address   Contact and Address Information\nRemittance Address   Remit To Address Information\nEmployer s Identification Number   Federal Tax ID\nDUNS (Data Universal Numbering System)\n\nCODES, STANDARDS AND EXECUTIVE ORDERS:\n\nVA has adopted the latest edition of the following codes and standards as a minimum for all projects performed in the modernization, alteration, addition, or improvement of its real property and the construction of new structures. VA design Manuals and Master Specifications specify other codes and standards that VA follows on its projects:\n\nVA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).\nPG-18-1 Master Construction Specifications\nPG-18-3 Design and Construction Procedures\nPG-18-4 Standard Details and CAD Standards\nVA BIM Manual V2.2\nPG-18-5 Equipment Guide List\nH-18-8 VA Seismic Design Handbook\nPG-18-9 Space Planning Criteria\nPG-18-10 Design Manuals (by discipline)\nPG-18-12 Design Guides (graphical, by function)\nPG-18-13 Barrier Free Design Guides\nPG-18-14 Room Finishes, Door, and Hardware Schedules (consult COR for local standards)\nPG-18-15 Minimum Requirements for A/E Submissions\nPG-18-17 Environmental Compliance Manual\nH-7545 VA Cultural Resource Management\n\nVA Handbook 0056, Sustainable Building Program\nVA Directive 0056, Sustainable Building Program\nVA Directive 0055, VA Energy and Water Management Program \n\nNFPA 101 Life Safety Code \n\nNFPA National Fire Codes \n\nInternational Building Code (IBC) and all other International Code Series (IPC, IMC, IECC, IFGC, etc.) when applicable or referenced in VA Design documents/ guides.  \n\nOccupational, Safety and Health Administration (OSHA) Standards.\n\nNational Electrical Code (NEC)\n\nSafety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.\n\nASME Boiler and Pressure Vessel Code\n\nASME Code for Pressure Piping\n\nArchitectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)\n\nBuilding Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)\n\nManual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)\n\nEnergy policy Act of 2007 (EPAct)\n\nDOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High-Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.\n\nFederal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)\n\nExecutive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.\n\nThe Provisions for Construction and Safety Signs.  Stated in the General Requirements Section 01010 of the VA Master Construction Specification.\n\nVentilation for Acceptable Indoor Air Quality   ASHRAE Standard 62.1- 2013.\n\nSafety Standard for Refrigeration Systems   ASHRAE Standard 15   2016.","origin":"detail"},"contacts":[{"name":"Christina Beeler-Blackburn (CO)","role":"primary","email":"Christina.Beeler-Blackburn@va.gov","title":"Contract Officer"}],"place_of_performance":null,"office_address":{"zip":"80111","city":"Greenwood Village","state":"CO","country":"USA"},"naics_codes":["236220"],"award":null,"attachments":[{"resource_id":"d6b9097756c541ef9434007f565f5fce","name":"36C25926R0082.docx","kind":"file","mime_type":".docx","size_bytes":24356,"posted_at":"2026-07-06T21:00:26.063Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d6b9097756c541ef9434007f565f5fce/download","mirrored":false},{"resource_id":"01d65ea977fa48409cce2f2a45c8a967","name":"36C25926R0082_1.docx","kind":"file","mime_type":".docx","size_bytes":153979,"posted_at":"2026-07-23T21:45:40.887Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/01d65ea977fa48409cce2f2a45c8a967/download","mirrored":false},{"resource_id":"ed3b4942f18c49328dc3de9a0985a32b","name":"36C25926R0082_1.docx","kind":"file","mime_type":".docx","size_bytes":153979,"posted_at":"2026-07-23T21:45:17.523Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ed3b4942f18c49328dc3de9a0985a32b/download","mirrored":false}],"awards":[],"related":[{"key":"36C25927Q0058","latest_notice_id":"f7ba8da853564af6a36ca00b9a898459","title":"Q301--NEW | Automated Blood Bank Solid Phase Analyzer and Associated Reagents/Consumables","solicitation_number":"36C25927Q0058","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-25T22:30:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"334516","psc":"Q301","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"36C25927Q0048","latest_notice_id":"c63e9c1e32f4475caa79c878ba87ca2f","title":"Radiant Heating Panel Replacement","solicitation_number":"36C25927Q0048","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-23","notices":3,"due_at":"2026-11-27T19:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":"SBA","state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C25927Q0061","latest_notice_id":"2844a59e27da407db5c5aac404bd35d7","title":"AI tool for Medication Reconciliation and Clinical Review","solicitation_number":"36C25927Q0061","notice_type":"r","first_type":"r","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"541519","psc":"DA10","set_aside":null,"state":"CO","county":"08077","county_name":"Mesa County","city":"0831660","city_name":"Grand Junction","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C25927Q0060","latest_notice_id":"dab1ae13fa4543da8629e3ba28875296","title":"J023-- Transmission Repair/Replacement x2","solicitation_number":"36C25927Q0060","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T17:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"811111","psc":"J023","set_aside":"SBA","state":"UT","county":"49035","county_name":"Salt Lake County","city":"4967000","city_name":"Salt Lake City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C25927Q0063","latest_notice_id":"3aec52f34d1346bcb89262decf41e0e9","title":"J045--Annual Boiler Maintenance RMR VAMC","solicitation_number":"36C25927Q0063","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C259","office_name":"NETWORK CONTRACT OFFICE 19 (36C259)","naics":"238220","psc":"J045","set_aside":null,"state":"CO","county":"08001","county_name":"Adams County","city":"0804000","city_name":"Aurora","country":"USA","place_scope":"site","state_source":"sam_zip","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"W912BV26RA016","latest_notice_id":"740b633947c4437eb506d23018133490","title":"Child Development Center (CDC), Tinker Air Force Base, Oklahoma","solicitation_number":"W912BV26RA016","notice_type":"o","first_type":"p","first_posted":"2026-08-13","last_posted":"2026-11-17","notices":7,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912BV","office_name":"W076 ENDIST TULSA","naics":"236220","psc":"Y1CZ","set_aside":null,"state":"OK","county":"40109","county_name":"Oklahoma County","city":"4048350","city_name":"Midwest City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Tinker Air Force Base","site_key":"tinker-air-force-base-ok","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"TPSBATHROOMUPGRADES","latest_notice_id":"0269b7f9e6d244f9b35d161bb47e033e","title":"Thomas P. Stafford Building (TPS) Restroom Upgrades at the Mike Monroney Aeronautical Center (MMAC), Oklahoma City, OK","solicitation_number":"TPSBathroomUpgrades","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-12-04T21:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-069","dept_name":"TRANSPORTATION, DEPARTMENT OF","sub_key":"s-6920","sub_name":"FEDERAL AVIATION ADMINISTRATION","office_key":"o-6973GH","office_name":"6973GH FRANCHISE ACQUISITION SVCS","naics":"236220","psc":"Y1AA","set_aside":null,"state":"OK","county":"40109","county_name":"Oklahoma County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"140RR027R0020","latest_notice_id":"0ffc297fb8d04c08899fd3a921e6b7a7","title":"Y--McGee Creek Natural Scenic Recreation Area (NSRA) Improvements","solicitation_number":"140RR027R0020","notice_type":"r","first_type":"r","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-12-04T22:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140RR0","office_name":"RECLAMATION CONTRACTING ACTIVITY","naics":"236220","psc":"Y1FB","set_aside":null,"state":"OK","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ION AREA (NSRA) IMPROVEMENTS PROJECT IN OKLAHOMA","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":193,"indexable":false}